Table Of Contents
TL1 Alarms and Errors
This chapter provides TL1 alarm and error information supported by the Cisco ONS 15454 and Cisco ONS 15327, including:
•Alarms
•Errors
•Echo
Each alarm includes a description and severity. Each error is listed by error code and includes error type and error message. For a list of TL1 conditions, see Table 4-46.
7.1 Alarms
Refer to "Alarm Troubleshooting" in the Cisco ONS 15454 Troubleshooting Guide and in the Cisco ONS 15327 User Documentation for complete alarm definitions, trouble notifications, and fault recovery procedures. The alarms are listed alphabetically by alarmable object:
• AIP
• EXT-SREF
• BITS
• FAN
• BPLANE
• G1000
• DS1
• NE
• DS3
• NE-SREF
• E1000F
• OCN
• E100(T)
• STSMON
• EC1-12
• STSTRM
• ENVALRM
• VT-MON
• EQPT
• VT-TERM
For a sample of each TL1 alarm that can be generated by the ONS 15454, refer to the file 15454_r33_tl1_alarms.txt on the Cisco ONS 15454 Software CD in the subdirectory \TL1. For a sample of each TL1 alarm that can be generated by the ONS 15327, refer to the file 15327_r33_tl1_alarms.txt on the Cisco ONS 15327 Software CD in the subdirectory \TL1. These files can be used to test an operations support system's ability to receive alarms which the ONS 15454/ONS 15327 can raise.
7.1.1 AIP
Auxiliary interface protection module
7.1.2 BITS
Building integration timing supply (BITS) incoming references (BITS-1, BITS-2)
7.1.3 BPLANE
The backplane
7.1.4 DS1
A DS1 line on a DS1 or DS3XM card
7.1.5 DS3
A DS3 line
7.1.6 E1000F
An Ethernet line on an E1000
Table 7-6 E1000F
E1000F Alarm Severity (Active) DescriptionCARLOSS
MA/SA
The Ethernet card has lost its link and is not receiving any signal, even an invalid one.
7.1.7 E100(T)
An Ethernet line on an E10 or E100
Table 7-7 E100(T)
E100T Alarm Severity (Active) DescriptionCARLOSS
MA/SA
The Ethernet card has lost its link and is not receiving any signal, even an invalid one.
7.1.8 EC1-12
An EC1 line on an EC1 card (ONS 15454 only)
7.1.9 ENVALRM
An environmental alarm port on an AIC card (ONS 15454) or MIC card (ONS 15327)
Table 7-9 ENVALRM
ENVALRM Alarm Severity (Active) DescriptionEXT
MA/SA
A facility alarm is detected external to the node because an environmental alarm is present.
7.1.10 EQPT
A card in any of the card slots. This object is used for alarms that refer to the card itself and all other objects on the card including ports, lines, STS and VT.
7.1.11 EXT-SREF
BITS outgoing references (SYNC-BITS1, SYNC-BITS2)
7.1.12 FAN
Fan-tray assembly
7.1.13 G1000
An Ethernet line on a G1000 (ONS 15454 only)
7.1.14 NE
The entire network element (SYSTEM)
7.1.15 NE-SREF
Represents the timing status of the NE
7.1.16 OCN
An OCN line on an OCN card
7.1.17 STSMON
STS alarm detection at the monitor point (upstream of cross-connect)
7.1.18 STSTRM
STS alarm detection at termination (downstream of cross-connect)
7.1.19 VT-MON
VT1 alarm detection at the monitor point (upstream of cross-connect)
7.1.20 VT-TERM
VT1 alarm detection at termination (downstream of cross-connect)
7.2 Errors
Errors may be generated by any command or command response message. The format of an error message is as follows:
SID DATE TIME
M CTAG DENY
<ERRCDE>
/* <ERRMSG> */
;
7.3 Echo
In order to improve telnet functionality for automated systems, the echo function has been turned off since ONS 15454 Release 3.0. This change is transparent to users running standard UNIX-compliant telnet clients; however, PC users may need to change their client setup to enable "local echo." This is normally accomplished by a pull-down menu or a preference attribute.
To test the local echo on your PC client, use the RTRV-HDR command. If you receive a response but no data, set local echo ON. Cisco recommends that you close any windows containing sensitive information after exiting a TL1 session.
Posted: Fri Feb 22 12:32:56 PST 2008