TL1 Alarms and Errors

7.1 Alarms

7.1.1 AIP

7.1.2 BITS

7.1.3 BPLANE

7.1.4 DS1

7.1.5 DS3

7.1.6 E1000F

7.1.7 E100(T)

7.1.8 EC1-12

7.1.9 ENVALRM

7.1.10 EQPT

7.1.11 EXT-SREF

7.1.12 FAN

7.1.13 G1000

7.1.14 NE

7.1.15 NE-SREF

7.1.16 OCN

7.1.17 STSMON

7.1.18 STSTRM

7.1.19 VT-MON

7.1.20 VT-TERM

7.2 Errors

7.3 Echo


TL1 Alarms and Errors


This chapter provides TL1 alarm and error information supported by the Cisco ONS 15454 and Cisco ONS 15327, including:

Alarms

Errors

Echo

Each alarm includes a description and severity. Each error is listed by error code and includes error type and error message. For a list of TL1 conditions, see Table 4-46.

7.1 Alarms

Refer to "Alarm Troubleshooting" in the Cisco ONS 15454 Troubleshooting Guide and in the Cisco ONS 15327 User Documentation for complete alarm definitions, trouble notifications, and fault recovery procedures. The alarms are listed alphabetically by alarmable object:

AIP

EXT-SREF

BITS

FAN

BPLANE

G1000

DS1

NE

DS3

NE-SREF

E1000F

OCN

E100(T)

STSMON

EC1-12

STSTRM

ENVALRM

VT-MON

EQPT

VT-TERM


For a sample of each TL1 alarm that can be generated by the ONS 15454, refer to the file 15454_r33_tl1_alarms.txt on the Cisco ONS 15454 Software CD in the subdirectory \TL1. For a sample of each TL1 alarm that can be generated by the ONS 15327, refer to the file 15327_r33_tl1_alarms.txt on the Cisco ONS 15327 Software CD in the subdirectory \TL1. These files can be used to test an operations support system's ability to receive alarms which the ONS 15454/ONS 15327 can raise.

7.1.1 AIP

Auxiliary interface protection module

Table 7-1 AIP

AIP Alarm
Severity (Active)
Description

INVMACADR

MA/NSA

The ONS 15454/15327 media access control layer address (MAC address) is invalid.

MEA

CR/SA

The mismatch between entity/equipment type and provisioned attributes alarm occurs when the physical card inserted in a slot does not match the card type that is provisioned for that slot in the CTC.

MFGMEM

CR/SA

The manufacturing data memory failure alarm means that the ONS 15454/15327 cannot access the data on the erasable programmable read-only memory (EPROM).


7.1.2 BITS

Building integration timing supply (BITS) incoming references (BITS-1, BITS-2)

Table 7-2 BITS

BITS Alarm
Severity (Active)
Description

LOF

MA/SA

A port on the TCC+/MIC BITS input detects a loss of frame (LOF) on the incoming BITS timing reference signal.

LOS

MA/SA

The TCC+/MIC card has a loss of signal (LOS) condition from the BITS timing source.

SSM-FAIL

MI/NSA

Synchronization status messaging failed.


7.1.3 BPLANE

The backplane

Table 7-3 BPLANE

BPLANE Alarm
Severity (Active)
Description

MFGMEM

CR/SA

The manufacturing data memory failure alarm means that the ONS 15454/15327 cannot access the data on the erasable programmable read-only memory (EPROM).


7.1.4 DS1

A DS1 line on a DS1 or DS3XM card

Table 7-4 DS1

DS1 Alarm
Severity (Active)
Description

LOF

MA/SA

The receiving ONS 15454/15327 has lost frame delineation in the incoming data.

LOS

MA/SA

A loss of signal (LOS) at the card for either a DS-3 port or a DS-1 port.

RCVR-MISS

MA/SA

The facility termination equipment detects a missing receive cable on the DS-1 port or a possible mismatch of backplane equipment.

TRMT

MA/SA

There is a transmission failure on the DS-1 card due to an internal hardware failure.

TRMT-MISS

MA/SA

The facility termination equipment detects a missing transmit cable on the DS-1 port or a possible mismatch of backplane equipment.


7.1.5 DS3

A DS3 line

Table 7-5 DS3

DS3 Alarm
Severity (Active)
Description

LOF

CR/SA

The receiving ONS 1545415327 has lost frame delineation in the incoming data.

LOS

CR/SA

Loss of signal at the card for either a DS-3 port or a DS-1 port.


7.1.6 E1000F

An Ethernet line on an E1000

Table 7-6 E1000F

E1000F Alarm
Severity (Active)
Description

CARLOSS

MA/SA

The Ethernet card has lost its link and is not receiving any signal, even an invalid one.


7.1.7 E100(T)

An Ethernet line on an E10 or E100

Table 7-7 E100(T)

E100T Alarm
Severity (Active)
Description

CARLOSS

MA/SA

The Ethernet card has lost its link and is not receiving any signal, even an invalid one.


7.1.8 EC1-12

An EC1 line on an EC1 card (ONS 15454 only)

Table 7-8 EC1-12

EC1-12 Alarm
Severity (Active)
Description

LOF

CR/SA

The receiving ONS 15454 has lost frame delineation in the incoming data.

LOS

CR/SA

A port on the reporting EC-1 card has a loss of signal condition. A SONET receiver detects an all-zero pattern for 10 microseconds or longer.


7.1.9 ENVALRM

An environmental alarm port on an AIC card (ONS 15454) or MIC card (ONS 15327)

Table 7-9 ENVALRM

ENVALRM Alarm
Severity (Active)
Description

EXT

MA/SA

A facility alarm is detected external to the node because an environmental alarm is present.


7.1.10 EQPT

A card in any of the card slots. This object is used for alarms that refer to the card itself and all other objects on the card including ports, lines, STS and VT.

Table 7-10 EQPT 

EQPT Alarm
Severity (Active)
Description

AUTORESET

MI/NSA

The card is performing a warm reboot automatically.

BKUPMEMP

CR/NSA

A problem with the TCC+/XTC card's flash memory.

CARLOSS

MI/NSA

The Ethernet card has lost its link and is not receiving any signal, even an invalid one.

CONTBUS-A-18

MA/NSA

The main processor on the TCC+/XTC card in Slot 7/Slot 5 has lost communication with the coprocessor on the second TCC+/XTC card in Slot 11/Slot 6.

CONTBUS-A

MA/NSA

The TCC+/XTC card in Slot 7/Slot 5 has lost communication with a line card.

CONTBUS-B-18

MA/NSA

The main processor on the TCC+/XTC card in Slot 11/Slot 6 has lost communication with the coprocessor on the TCC+/XTC card in Slot 7/Slot 5.

CONTBUS-B

MA/NSA

The TCC+/XTC card in Slot 11/Slot 6 has lost communication with a line card.

CTNEQPT-PBPROT

CR/SA

A failure of the main payload between the protect cross-connect (XC/XCVT/XC10G) card in Slot 10, or the protect XTC card, and the reporting traffic card.

CTNEQPT-PBWORK

CR/SA

The main payload bus between the active cross-connect (XC/XCVT/XC10G) card in Slot 8, or the active XTC card, and the reporting traffic card.

EQPT

CR/SA

A hardware failure occurred on the reporting card.

EXCCOL

MI/NSA

There are too many collisions are occurring on the network management LAN.

HITEMP

MI/NSA

The temperature of the ONS 15454/ONS 15327 is above 50 degrees Celsius.

IMPROPRMVL

CR/SA

A card was physically removed from its slot before the card was deleted in CTC.

MEA

CR/SA

The mismatch between entity/equipment type and provisioned attributes alarm occurs when the physical card inserted in a slot does not match the card type that is provisioned for that slot in the CTC.

MEM-GONE

MA/NSA

Data generated by software operations exceeds the memory capacity of the TCC+/XTC card.

MEM-LOW

MI/NSA

Data generated by software operations is close to exceeding the memory capacity of the TCC+XTC card.

PEER-
NORESPONSE

MA/NSA

The switch agent raises a Peer Card Not Responding alarm if either I/O card in a protection group does not receive a response to the peer status request message.

SFTWDOWN-FAIL

MI/NSA

The software download from the TCC+/XTC card to the ONS 15454 failed.

SNTP-HOST

MI/NSA

An ONS node serving as an IP proxy for the other ONS nodes in the ring is not forwarding SNTP information to the other ONS nodes in the network.

SWMTXMOD

CR/SA

Traffic on the reporting card is lost when this failure occurs.


7.1.11 EXT-SREF

BITS outgoing references (SYNC-BITS1, SYNC-BITS2)

Table 7-11 EXT-SREF

EXT-SREF Alarm
Severity (Active)
Description

SYNCPRI

MI/NSA

A loss of the primary timing source (reference 1).

SYNCSEC

MI/NSA

A loss of the secondary timing source (reference 2).

SYNCTHIRD

MI/NSA

A loss of the third timing source (reference 3).


7.1.12 FAN

Fan-tray assembly

Table 7-12 FAN 

FAN Alarm
Severity (Active)
Description

EQPT-MISS

CR/SA

Indicates the replaceable fan tray assembly unit is missing or not fully inserted.

FAN

CR/SA

A problem with the fan-tray assembly.

MEA

CR/SA

The mismatch between entity/equipment type and provisioned attributes alarm occurs when the physical card inserted in a slot does not match the card type that is provisioned for that slot in the CTC.

MFGMEM

CR/SA

The manufacturing data memory failure alarm means that the ONS 15454/ONS 15327cannot access the data on the erasable programmable read-only memory (EPROM).


7.1.13 G1000

An Ethernet line on a G1000 (ONS 15454 only)

Table 7-13 G1000

NE Alarm
Severity (Active)
Description

CARLOSS

MA/SA

A carrier loss on the LAN is the data equivalent of a SONET LOS alarm. The Ethernet card has lost its link and is not receiving a valid signal.

TPTFAIL

MA/SA

Indicates a break in the end-to-end Ethernet link integrity feature of the G1000-4 cards. This alarm indicates a far-end condition and not a problem with the port reporting TPTFAIL.


7.1.14 NE

The entire network element (SYSTEM)

Table 7-14 NE 

NE Alarm
Severity (Active)
Description

BLSROSYNC

MA/SA

The mapping table needs updating.

DATAFLT

MI/NSA

The database exceeded the capacity of the flash memory on the TCC+/XTC.

EHIBATVG-A

MA/SA

The voltage level on battery lead A exceeds -56.7 Vdc. (ONS 15454)

EHIBATVG-B

MA/SA

The voltage level on battery lead B exceeds -56.7 Vdc. (ONS 15454)

ELWBATVG-A

MA/SA

The voltage on battery feed A is extremely low or has been lost, and power redundancy is no longer guaranteed. (ONS 15454)

ELWBATVG-B

MA/SA

The voltage on battery feed B is extremely low or has been lost, and power redundancy is no longer guaranteed. (ONS 15454)

HITEMP

CR/SA

The temperature of the ONS 15454/ONS 15327 is above 50 degrees Celsius (122 degrees Fahrenheit).

PRC-DUPID

MA/SA

Two identical node IDs exist in the same ring.

PWR-A

MA/SA

This alarm applies to the NE rack. It is raised when there is no power supplied to the main power connector or if power is connected to the backup power connector (Connector B) but not to Connector A. (ONS 15454)

PWR-B

MA/SA

This alarm applies to the NE rack. It is raised when there is no power supplied to the backup power connector or if power is connected to the main power connector (Connector A) but not to Connector B. (ONS 15454)

NE Alarm
Severity (Active)
Description

RING-MISMATCH

MA/SA

The Ring ID of the ONS 15454/ONS 15327that is reporting the alarm does not match the Ring ID of another ONS node in the BLSR.

SYSBOOT

MA/SA

New software is booting on the TCC+/XTC card.


7.1.15 NE-SREF

Represents the timing status of the NE

Table 7-15 NE-SREF

NE-SREF Alarm
Severity (Active)
Description

FRNGSYNC

MA/SA

The reporting ONS 15454/ONS 15327 is in free run synchronization mode.

FSTSYNC

MI/NSA

A fast start synchronization. The ONS 15454/ ONS 15327 is choosing a new timing reference.

HLDOVRSYNC

MA/SA

A loss of primary/secondary timing reference.

SYNCPRI

MI/NSA

A loss of the primary timing source (reference 1).

SYNCSEC

MI/NSA

A loss of the secondary timing source (reference 2).

SYNCTHIRD

MI/NSA

A loss of the third timing source (reference 3).


7.1.16 OCN

An OCN line on an OCN card

Table 7-16 OCN 

OCN Alarm
Severity (Active)
Description

APSB

MI/NSA

The line terminating equipment detects protection switching byte failure in the incoming automatic protection switching (APS) signal if an inconsistent APS byte or invalid code is detected.

APSCDFLTK

MI/NSA

A BLSR is not properly configured.

APSC-IMP

MI/NSA

Invalid K bytes.

APSCINCON

MI/SA

The SONET overhead contains K1/K2 APS bytes that notify receiving equipment, such as the ONS 15454/ONS 15327, to switch the SONET signal from a working to a protect path.

APSCM

MA/SA

The ONS 15454/ONS 15327 expects a working channel but receives a protection channel.

APSCNMIS

MA/SA

The node ID contained in the K2 byte of the APS channel being received is not present in the ring map.

APSMM

MI/NSA

There is a mismatch of the protection switching schemes at the two ends of the span.

AUTOLSROFF

CR/SA

The OC-192 card temperature exceeds 90 degrees Centigrade. The internal equipment automatically shuts down the OC-192 laser when the card temperature rises to prevent the card from self-destructing.(ONS 15454)

AUTORESET

MI/NSA

A card performs a warm reboot automatically.

EOC

MA/NSA

The ONS 15454/ONS 15327 has lost its data communications channel (DCC).

E-W-MISMATCH

MA/SA

Nodes in a ring have an east slot/port misconnected to another east slot/port or a west slot/port misconnected to another west slot/port.

FEPRLF

MI/NSA

An automatic protection switching channel failure on a signal coming into the node.

LOF

CR/SA

A port on the reporting OC-N card has an LOF condition.

LOS

CR/SA

A port on the reporting OC-N card has a LOS condition.

SSM-FAIL

MI/NSA

Synchronization status messaging received by the ONS 15454/ONS 15327 failed


7.1.17 STSMON

STS alarm detection at the monitor point (upstream of cross-connect)

Table 7-17 STSMON

STSMON Alarm
Severity (Active)
Description

CONCAT

CR/SA

The transmitted STSc circuit is smaller than the provisioned STSc causing a mismatch of the circuit type on the concatenation facility.

FAILTOSW

MI/NSA

Fail to switch to protection.

LOP-P

CR/SA

A loss of pointer (LOP) condition at the path level.

PLM-P

CR/SA

A signal label mismatch failure (SLMF).

TIM-P

MI/NSA

The expected path trace string does not match the received path trace string.

UNEQ-P

CR/SA

The path does not have a valid sender.


7.1.18 STSTRM

STS alarm detection at termination (downstream of cross-connect)

Table 7-18 STSTRM

STSTRM Alarm
Severity (Active)
Description

LOP-P

CR/SA

A loss of pointer (LOP) condition at the path level.

PLM-P

CR/SA

A signal label mismatch failure (SLMF).

TIM-P

MI/NSA

The expected path trace string does not match the received path trace string. Path trace mode can be set to auto or manual for this alarm to occur.

UNEQ-P

CR/SA

The path does not have a valid sender.


7.1.19 VT-MON

VT1 alarm detection at the monitor point (upstream of cross-connect)

Table 7-19 VT-MON

VT-MON Alarm
Severity (Active)
Description

AUTOSW-LOP

MI/SA

Automatic UPSR protection switching took place because of an LOP alarm.

AUTOSW-
UNEQ

MI/SA

Automatic UPSR protection switching took place because of an UNEQ alarm.

LOP-V

MA/SA

A loss of pointer at the VT level.

UNEQ-V

MA/SA

The node is receiving SONET path overhead with bits 5, 6 and 7 of the V5 overhead byte all set to zeroes. The failure has occurred at the VT layer.


7.1.20 VT-TERM

VT1 alarm detection at termination (downstream of cross-connect)

Table 7-20 VT-TERM

VT-TERM Alarm
Severity (Active)
Description

LOP-V

MA/SA

A loss of pointer at the VT level.

PLM-V

MI/SA

The content of the V5 byte in the SONET overhead is inconsistent or invalid.

UNEQ-V

MA/SA

The node is receiving SONET path overhead with bits 5, 6 and 7 of the V5 overhead byte all set to zeroes. The failure has occurred at the VT layer.


7.2 Errors

Errors may be generated by any command or command response message. The format of an error message is as follows:

SID DATE TIME
M CTAG DENY
<ERRCDE>
/* <ERRMSG> */
;

Table 7-21 Error Codes 

Error Code
(ERRCDE)
Error Type
Error Message (ERRMSG)

EANS

EQUIPAGE

Access Not Supported

EATN

EQUIPAGE

Not Valid for Access Type

EFON

EQUIPAGE

Feature Option not Provided

EN2T

EQUIPAGE

Not 2-wire Terminate and Leave

ENAC

EQUIPAGE

Not Equipped with Alarm Cutoff

ENAD

EQUIPAGE

Not Equipped with Audit Capability

ENAR

EQUIPAGE

Not Equipped with Automatic Reconfiguration

ENAT

EQUIPAGE

Request Not Valid for Access Type

ENDG

EQUIPAGE

Not Equipped with Diagnostic Capability

ENDS

EQUIPAGE

Not Equipped with Duplex Switching

ENEA

EQUIPAGE

Not Equipped with Error Analysis Capability

ENEQ

EQUIPAGE

Not Equipped

ENEX

EQUIPAGE

Not Equipped with Exercise Capability

ENFE

EQUIPAGE

Feature not Provided

ENFL

EQUIPAGE

Not Equipped for Fault Locating

ENHN

EQUIPAGE

Not Hybrid Network

ENMB

EQUIPAGE

Not Multipoint Bridge

ENMD

EQUIPAGE

Not Equipped with Memory Device

ENPM

EQUIPAGE

Not Equipped for Performance Monitoring

ENPS

EQUIPAGE

Not Equipped with Protection Switching

ENRE

EQUIPAGE

Not Recognized Equipage

ENRI

EQUIPAGE

Not Equipped for Retrieving Specified Information

ENRS

EQUIPAGE

Not Equipped for Restoration

ENSA

EQUIPAGE

Not Equipped for Scheduling Audit

ENSG

EQUIPAGE

Not Software Generic

ENSI

EQUIPAGE

Not Equipped for Setting Specified Information

ENSS

EQUIPAGE

Not Equipped with Synchronization Switching

ENTL

EQUIPAGE

Not Terminate and Leave

ERLC

EQUIPAGE

Red-Lined Circuit

ERNS

EQUIPAGE

RTU Does Not Support Command

ESPG

EQUIPAGE

Software Program

ETNS

EQUIPAGE

TSC Does Not Support Command

FNCR

FAULT

NE Failure - Circuit Restored to Last Condition - Monitor or Terminate

FNDT

FAULT

No Dial Tone Detected

FNEC

FAULT

NTE Has Lost 8-KHZ Byte Clock

FNSC

FAULT

NTE Has Lost 16-KHZ Byte Clock

FRCE

FAULT

RTU Component or Configuration Error

FRDA

FAULT

RTU Does Not Answer the Call

FREC

FAULT

RTU Eight KHZ Byte Clock Lost

FRNR

FAULT

RTU Does Not Reply

IBEX

INPUT

Block Extra

IBMS

INPUT

Block Missing

IBNC

INPUT

Block Not Consistent

ICNV

INPUT

Command Not Valid

IDMS

INPUT

Data Missing

IDNC

INPUT

Data Not Consistent

IDNV

INPUT

Data Not Valid

IDRG

INPUT

Data Range Error

IIAC

INPUT

Invalid Access Identifier (AID)

IICM

INPUT

Invalid Command

IICT

INPUT

Invalid Correlation Tag

IIDT

INPUT

Invalid Data Parameter

IIFM

INPUT

Invalid Data Format

IIPG

INPUT

Invalid Parameter Grouping

IISP

INPUT

Invalid Syntax or Punctuation

IITA

INPUT

Invalid Target Identifier

INAC

INPUT

Access Number Not Correct

INUP

INPUT

Non-Null Unimplemented Parameter

IPEX

INPUT

Parameter Extra

IPMS

INPUT

Parameter Missing

IPNC

INPUT

Parameter Not Consistent

IPNV

INPUT

Parameter Not Valid

ISCH

INPUT

Syntax Invalid Character

ISPC

INPUT

Syntax Punctuation

ITSN

INPUT

Invalid/Inactive Test Session Number

PICC

PRIVILEGE

Illegal Command Code

PIMA

PRIVILEGE

Invalid Memory Address

PIMF

PRIVILEGE

Invalid Memory File

PIUC

PRIVILEGE

Illegal Privilege Code

PLNA

PRIVILEGE

Login Not Active

RABY

RESOURCE

All Taps Busy

RALB

RESOURCE

All Units of Requested Type are Busy

RANB

RESOURCE

Access Network Busy

RCBY

RESOURCE

Circuit Busy

RCIN

RESOURCE

Requested Circuit ID Does Not Exist

RNAN

RESOURCE

Requested NE Access Number Does Not Exist

RNAU

RESOURCE

Requested NE Access Number Unassigned

RNBY

RESOURCE

NE is Busy

RRCP

RESOURCE

Unit Specified by Routing Code Busy

RRNG

RESOURCE

Requested Changes Exceeds Range

RTBY

RESOURCE

Requested Tap Busy

RTEN

RESOURCE

Requested Tab Does Not Exist

RTUB

RESOURCE

Test Unit Busy

SAAL

STATUS

Already Allowed

SAAS

STATUS

Already Assigned

SABT

STATUS

Aborted

SACS

STATUS

Access Unit Cannot Sync on Facility Signal

SADC

STATUS

Already Disconnected

SADS

STATUS

Access Unit in Diagnostic State

SAIN

STATUS

Already Inhibited

SAIS

STATUS

Already In-Service

SAMS

STATUS

Already in Maintenance State

SAOP

STATUS

Already Operated

SAOS

STATUS

Already Out-of-Service

SAPF

STATUS

Access Path Continuity Check Failed

SAPR

STATUS

Already in Protection State

SARB

STATUS

All Resources Busy

SATF

STATUS

Automatic Test Failed

SCAT

STATUS

Circuit is Already Connected to Another Tap

SCBS

STATUS

Channel Busy

SCIS

STATUS

Circuit in Split Condition

SCNA

STATUS

Command Not Able to be Aborted

SCNF

STATUS

Command Not Found

SCNS

STATUS

Circuit Not in Split Condition

SCOS

STATUS

Channel Out-of-Service

SCSD

STATUS

Can't Split DS0B Circuit

SCSN

STATUS

Invalid Command Sequence

SDAS

STATUS

Diagnosis Already Started

SDBE

STATUS

Internal Data Base Error

SDFA

STATUS

Duplex Unit Failed

SDLD

STATUS

Duplex Unit Locked

SDNA

STATUS

Dumple Unit Not Available

SDNC

STATUS

Input Data is Not Consistent With NE Data

SDNR

STATUS

Data Not Ready

SDNS

STATUS

Diagnosis Not Started Yet

SEOS

STATUS

NTE is Out-of-Service

SFAS

STATUS

Fault Locating Already Started

SFNS

STATUS

Fault Locating Not Started yet

SFYA

STATUS

Facility Reports Amber Alarm

SLNS

STATUS

Log Not Started Yet

SLOS

STATUS

TSC to RTU Link Out-of-Service

SNCC

STATUS

Not Cross-Connected

SNCN

STATUS

NTE Unable to Execute Command

SNDS

STATUS

NTE is in a Diagnostic State

SNIM

STATUS

NTE Access Complete, Circuit was in Monitor State

SNIS

STATUS

Not in Service

SNML

STATUS

No Monitor Line Established

SNNB

STATUS

NTE Could Not Sync on DS0B Signal

SNNS

STATUS

NTE Could Not Sync on DS-1 Signal

SNOS

STATUS

NTE is Out-of-Service

SNPR

STATUS

Not in Protection State

SNRM

STATUS

System Not in Restoration Mode

SNRS

STATUS

Not Reserved

SNSR

STATUS

No Switch Request Outstanding

SNVS

STATUS

Not in Valid State

SNYA

STATUS

NTE has Detected an Amber Alarm

SOSE

STATUS

Operating System Error

SOST

STATUS

Out-of-Service, Testing

SPFA

STATUS

Protection Unit Failed

SPLD

STATUS

Protection Unit Locked

SPNA

STATUS

Process Not Able to be Aborted

SPNF

STATUS

Process Not Found

SRAC

STATUS

Requested Access Configuration is Invalid

SRAN

STATUS

Unable to Release Access System

SRCI

STATUS

Requested Command(s) Inhibited

SRCN

STATUS

Requested Condition Already Exists

SROF

STATUS

Requested Operation Failed

SROS

STATUS

Required RTU Out of Service

SRQN

STATUS

Invalid Request

SRTN

STATUS

Unable to Release Tap

SRTO

STATUS

Reply Timeout Occurred

SSCE

STATUS

Systemic (SNIDER) Communications Error

SSNG

STATUS

Subrate Selected is Incorrect

SSNP

STATUS

Speed Selected is Incorrect

SSNQ

STATUS

Test Signal Not QRS

SSRD

STATUS

Switch Request Denied

SSRE

STATUS

System Resources Exceeded

STAB

STATUS

Test Aborted

STLC

STATUS

Tap Unable to Locate Channel

STNO

STATUS

TSC/RTU to TAU Link Out of service

STOS

STATUS

Test Access Unit Out of Service

STTI

STATUS

Tap Idle

SWFA

STATUS

Working Unit Failed

SWLD

STATUS

Working Unit Locked


7.3 Echo

In order to improve telnet functionality for automated systems, the echo function has been turned off since ONS 15454 Release 3.0. This change is transparent to users running standard UNIX-compliant telnet clients; however, PC users may need to change their client setup to enable "local echo." This is normally accomplished by a pull-down menu or a preference attribute.

To test the local echo on your PC client, use the RTRV-HDR command. If you receive a response but no data, set local echo ON. Cisco recommends that you close any windows containing sensitive information after exiting a TL1 session.


hometocprevnextglossaryfeedbacksearchhelp

Posted: Fri Feb 22 12:32:56 PST 2008
All contents are Copyright © 1992--2008 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.