Table Of Contents
Single Optical S-16.1 Module, S16.1-1-LC
Single Optical S-16.1 Module, S16.1-1-LC
9.1 Module Description
The module contains one optical STM-16 interfaces that meets the S-16.1 specification in ITU-T G.957. The physical connector is a LC connector. The module only supports TDM traffic.
9.1.1 Power Consumption
13 W.
9.2 External Interface
The interface is an optical STM-16 short haul interface, according to clause 5 ITU-T G.957 The definitions of optical parameters and reference points S and R refer to ITU-T G.957. Reference point S means transmit direction while R is the receive direction of the fibre.
9.2.1 Connector Type
The physical connector is a LC connector.
Figure 9-1 Single Optical S-16.1 Module, S16.1-1-LC
9.2.2 Optical Budget
9.2.3 Traffic Alarms
•Rx direction
–Loss of signal (LOS): Traffic Alarm. Optical power of input signal is below receiver sensitivity level.
–Loss of lock (LOL):Indicates clock recovery of deserializer is out of lock. Signal must be present for indication to be valid. Indication to be reported as unit failure alarm.
–Transmit failure: Laser degradation
Posted: Fri Sep 14 10:49:36 PDT 2007
All contents are Copyright © 1992--2007 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.