cc/td/doc/product/ong/15305/305docs
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table Of Contents

Shelf Assembly Specifications

A.1  Mechanical Parameters

A.1.1  Chassis

A.1.2  Service Modules

A.1.3  Power Module, DC Power

A.1.4  System Controller Module, SYSCONT-SD128-RJ45

A.1.5  Alarm and Fan Module, FAN-ALARM

A.2  Reliability, MTBF

A.3  Environmental Conditions

A.3.1  Health and Safety

A.3.2  Storage and Transport

A.4  Referenced Specifications

A.4.1  ITU-T Recommendations

A.4.2  Cenelec Documents

A.4.3  ETSI Documents

A.4.4  IEC Documents

A.4.5  Bellcore Documents


Shelf Assembly Specifications


This appendix provides specifications for the Cisco ONS 15305.

A.1  Mechanical Parameters

A.1.1  Chassis

The equipment is provided as a sub-rack suitable for mounting within a 19-inch equipment cabinet. The height of the unit is 43.6 mm (1U =44.45mm).

Table A-1 lists the minimum dimensions required to mount a single unit, including power supply, cable termination, and fiber handling facilities.

Table A-1 Chassis Dimensions

Width

445mm

Height

43.6mm

Length

280mm


The depth of the sub-rack is 240 mm. The total weight of the ONS 15305 fully equipped does not exceed 5 Kg.

Different mounting brackets are available for both 19-inch and ETSI cabinets/racks (as specified in ETS 300 119, IEC 60917, and IEC 60297).

The thermal design of the unit meets the requirements of EN/IEC 60950.

A.1.2  Service Modules

Table A-2 lists the physical dimensions of the ONS 15305 service modules.

Table A-2 Service Module Dimensions  

Length

175mm

Height

41mm

Width

75mm


A.1.3  Power Module, DC Power

Table A-3 list the physical dimensions of the power module.

:

Table A-3 Power Module Dimensions

Length

230mm

Height

19mm

Width

44mm


A.1.4  System Controller Module, SYSCONT-SD128-RJ45

Table A-4 lists the physical dimensions of the system controller module.

Table A-4 System Controller Module Dimensions

Length

175mm

Height

19mm

Width

95mm


A.1.5  Alarm and Fan Module, FAN-ALARM

Table A-5 lists the physical dimensions of the Alarm and Fan module.

Table A-5 Alarm and Fan Module Dimensions

Length

236mm

Height

41mm

Width

28mm


A.2  Reliability, MTBF

MTBF values comply with Telcordia Technologies Special Report, SR-332, Issue 1, May 2001, but with the following corrections:

A Correction Factor, CF=2, has been used to improve the reliability figures.

For components where the manufacturer's reliability figures have been used, no further correction has been applied.

Table A-6 MTBF Values

Item
MTBF [Years]
40oC ambient temperature
Ground Benign]

64x64/20G Base module without FAN-ALARM

47

FAN-ALARM

74,8

DC Power

168,1

SYSCONT-SD128-RJ45

97

MAIN CARD

97,5

BACKPLANE

82,8

S1.1-8-LC

72,6

S16.1-1-LC

160,6

GigE-2-LC

102,5

E100-8

159,9

E1-8

212

E1-63

88,9

S4.1-2-LC

162,7

6XE3/T3-1.0/2.3

126,9

S1.1-2-LC

270,9


A.3  Environmental Conditions

The equipment conforms to the requirement of EN 300 386 for EMC related specifications. The equipment is also compliant with the following standards:

ETSI EN 300 386

EN 55022

EN 55024

EN 61000-4-2

EN 61000-4-3

EN 61000-4-4

EN 61000-4-5

EN 61000-4-6

EN60950, The Low Voltage Directive.

The equipment operates under all environmental conditions detailed in ETS 300 019-2-3 Class 3.2.

A.3.1  Health and Safety

The equipment meets the requirements in EN/IEC 60950 (CLASS III) and EN60825.

The equipment meets the requirements in ETS 300 753 for acoustic noise.

A.3.2  Storage and Transport

The equipment meets the requirements in ETS 300 019, Class 1.2 and class 2.2.

The supported storage temperature range is -40OC to +70OC.

A.4  Referenced Specifications

A.4.1  ITU-T Recommendations

G.652

Single Mode Optical Fiber

G.701

Vocabulary of Transmission and Multiplexing, and Pulse Code Modulation (PCM) Terms.

G.702

Digital Hierarchy Bit Rates

G.703

Physical/Electrical Characteristics of Hierarchical Digital Interfaces

G.704

Synchronous Frame Structures at Primary and Secondary Hierarchical levels.

G.706

Frame Alignment and Cyclic Redundancy Check (CRC) Procedures Relating to Basic Frame Structures Defined in Recommendation G.704

G.707

Network node interface for the synchronous digital hierarchy (SDH)

G.783

Characteristics of synchronous digital hierarchy (SDH) equipment functional blocks

G.784

Synchronous digital hierarchy (SDH) management

G.810

Definition and terminology for synchronization networks

G.811

Timing characteristic of primary reference clocks

G.812

Timing characteristics of slave clocks suitable for use as a node clocks in synchronization networks

G.813

Timing characteristics of SDH equipment slave clocks (SEC)

G.823

The control of jitter and wander within digital networks which are based on the 2048 kbps hierarchy

G.825

The control of jitter and wander within digital networks which are based on the synchronous digital hierarchy (SDH)

G.832

Transport of SDH elements on PDH networks - Frame and multiplexing structures

G.841

Types and characteristics of SDH network protection architectures

G.957

Optical interfaces for equipment and systems relating to the synchronous digital hierarchy

G.958

Digital line systems based on the synchronous digital hierarchy for use on optical fiber cables

X.150

Principles of maintenance Testing for Public Data Network using Data Terminal Equipment (DTE) and Data Circuit-Terminating Equipment (DCE) test Loops

A.4.2  Cenelec Documents

EN 50082-1

Generic immunity standard Industrial environment

EN 55022

Specification for Limits and methods of Measurement of Radio Interference Characteristics of Information Technology Equipment

EN 55024

Electromagnetic Compatibility Requirements for Information Technology Equipment (Previously EN 55101)

EN 60825

Radiation Safety of Laser Products

EN 60950

Safety of Information Technology Equipment Including Electrical Business Equipment

EN 61000-3-2

Electromagnetic compatibility (EMC). Part 3: Limits; Section 2: Limits for harmonic current emissions (equipment input current Ј16 A per phase)

EN 61000-3-3

Electromagnetic compatibility (EMC). Part 3: Limits; Section 3: Limitation of voltage fluctuations and flicker in low-voltage supply systems for equipment with rated current Ј16 A

EN 61000-4-2

Electromagnetic compatibility (EMC). Part 4: Testing and measurement techniques; Section 2: Electrostatic discharge immunity test. Basic EMC Publication

EN 61000-4-3

Electromagnetic compatibility (EMC). Part 4: Testing and measurement techniques; Section 3: Radiated, radio-frequency, electromagnetic field immunity test

EN 61000-4-4

Electromagnetic compatibility (EMC). Part 4: Testing and measurement techniques; Section 4: Electrical fast transient/burst immunity test. Basic EMC Publication

EN 61000-4-5

Electromagnetic compatibility (EMC). Part 4: Testing and measurement techniques; Section 5: Surge immunity test

EN 61000-4-6

Electromagnetic compatibility (EMC). Part 4: Testing and measurement techniques; Section 6: Conducted disturbances induced by radio-frequency fields

A.4.3  ETSI Documents

ETS 300 011

Integrated Services Digital Network (ISDN); Primary rate user-network interface; Layer 1 specification and test principles

ETS 300 019-2-1

Environmental engineering (EE); Environmental conditions and environmental tests for telecommunication equipment Part 2-1: Specification of environmental test; Storage

ETS 300 019-2-2

Environmental engineering (EE); Environmental conditions and environmental tests for telecommunication equipment Part 2-2: Specification of environmental test; Transportation

ETS 300 019-2-3

Environmental engineering (EE); Environmental conditions and environmental tests for telecommunication equipment Part 2-2: Specification of environmental test; Stationary use at weather protected locations

ETS 300 119-4

Equipment engineering (EE): European telecommunication standard for equipment practice Part 4: Engineering requirements for subracks in miscellaneous racks and cabinets

ETS 300 132-2

Environmental engineering (EE): Power supply interface at the input to the telecommunication equipment: Part 2 Operated by direct current (dc)

ETS 300 147

Transmission and multiplexing (TM); Synchronous digital hierarchy (SDH); Multiplexing structure

ETS 300 233

Integrated Services Digital Network (ISDN); Access digital section for ISDN primary rate

ETS 300 253

Environmental engineering (EE): Earthing and bonding configuration inside telecommunication centres

ETS 300 386

Electromagnetic compatibility and radio spectrum matters (ERM); Telecommunication network equipment; Electromagnetic compatibility (EMC) requirements

ETS 300 752

Equipment engineering (EE): Acoustic noise emitted by telecommunication equipment

A.4.4  IEC Documents

IEC 60917-2

Modular order for the development of Mechanical structures for electronic equipment practice

IEC 60297-3

Dimension of mechanical structures of the 482.6mm (19 in) series Part 3 Subracks and associated plug-in units

A.4.5  Bellcore Documents

SR-332

Reliability prediction procedure for electronic equipment


hometocprevnextglossaryfeedbacksearchhelp

Posted: Fri Sep 14 11:09:55 PDT 2007
All contents are Copyright © 1992--2007 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.