Table Of Contents
ONS 15216 FlexLayer Module Specifications
A.1 Eight Channel Optical Add/Drop FlexLayer Module Specifications
A.2 Two Channel Optical Add/Drop FlexLayer Module Specifications
A.3 Optical Splitter or Coupler FlexLayer Module Specifications
A.4 Four Channel Variable Optical Attenuator (VOA) FlexLayer Module Specifications
ONS 15216 FlexLayer Module Specifications
A.1 Eight Channel Optical Add/Drop FlexLayer Module Specifications
A.2 Two Channel Optical Add/Drop FlexLayer Module Specifications
A.3 Optical Splitter or Coupler FlexLayer Module Specifications
Table A-3 Optical Splitter or Coupler FlexLayer Module Specifications
Parameter Condition Min Max UnitOperating Wavelength Range
CS-2, CS-3, CS-4
1529
1565
nm
CS-SM-Y1
1260/1430
1360/1580
CS-MM-Y 1
770/1260
860/1380
Insertion Loss
SPL-RX/CPL-TX
to any SPL-TXn/CPL-RXn1:2/2:1
3.5
4.3
dB
1:3/3:1
5.7
6.6
dB
1:4/4:1
7.3
8.2
dB
1:2&2:1SM
3.4
4.8
dB
1:2&2:1MM
3.4
5.5
CPL-TX to CPL-MON
15.5
20.5
SPL-RX to SPL-MON
15.5
20.5
Ripple2
Over Pass-Band
0.5
dB
Directivity
Any to any SPL-TXn/CPL-RXn
40
dB
Optical Return Loss3
Any port
40
dB
Polarization Dependent Loss
Any path
1:2/2:1
0.25
dB
1:3/3:1
0.3
1:4/4:1
0.4
1:2&2:1
0.25
Max Optical Power
Any port
250
mW
Connector Type
LC
1 Dual Window
2 For CS-MM-Y: 0.7dB
3 For CS-MM-Y: 25dB
A.4 Four Channel Variable Optical Attenuator (VOA) FlexLayer Module Specifications