ONS 15216 FlexLayer Module Specifications

A.1 Eight Channel Optical Add/Drop FlexLayer Module Specifications

A.2 Two Channel Optical Add/Drop FlexLayer Module Specifications

A.3 Optical Splitter or Coupler FlexLayer Module Specifications

A.4 Four Channel Variable Optical Attenuator (VOA) FlexLayer Module Specifications


ONS 15216 FlexLayer Module Specifications


A.1 Eight Channel Optical Add/Drop FlexLayer Module Specifications

Table A-1 Eight Channel Optical Add/Drop FlexLayer Module Specifications 

Parameter
Condition
Min
Max
Unit

Channel Plan

 

"4 skip 1":

ITU 21-24, 26-29, 31-34, 36-39, 41-44, 46-49, 51-54, 56-59

ITU Ch

Channel spacing

 

100

GHz

Channel Groups

15216-FLA-8-36.6

59, 58, 57, 56, 54, 53, 52, 51

ITU Ch

 

15216-FLA-8-44.5

49, 48, 47, 46, 44, 43, 42, 41

ITU Ch

 

15216-FLA-8-52.5

39, 38, 37, 36, 34, 33, 32, 31

ITU Ch

 

15216-FLA-8-60.6

29, 28, 27, 26, 24, 23, 22, 21

ITU Ch

Pass-Band

@ 0.5 dB

+/- 0.11

 

nm

Insertion Loss

DROP-COM-RX/ADD-COM-TX to DROP-CH-TX/ADD-CH-RX

3.4

4.5

dB

DROP-COM-RX/ADD-COM-TX to DROP-COM-TX/ADD-COM-RX

0.6

1.7

dB

DROP-COM-RX to DROP-MON

15.5

20.5

dB

ADD-COM-TX to ADD-MON

15.5

20.5

dB

Parameter
Condition
Min
Max
Unit

Isolation

DROP-COM-RX/ADD-COM-TX to any DROP-CH-TX/ADD-CH-RX @ adjacent channels

25

 

dB

DROP-COM-RX/ADD-COM-TX to DROP-COM-TX/ADD-COM-RX @ added/dropped channel wavelengths

14

 

dB

Ripple

Over Pass-Band

 

0.5

dB

Directivity

Any to any DROP-CH-TX/ADD-CH-RX

40

 

dB

Optical Return Loss

Any port

40

 

dB

Polarization Dependent Loss

Any path

 

0.2

dB

Max Optical Power

Any port

 

250

mW

Connector Type

LC

     

A.2 Two Channel Optical Add/Drop FlexLayer Module Specifications

Table A-2 Two Channel Optical Add/Drop FlexLayer Module Specifications 

Parameter
Condition
Min
Max
Unit

Channel Plan

 

"4 skip 1": ITU 21-24, 26-29, 31-34, 36-39, 41-44, 46-49, 51-54, 56-59

ITU Ch

Channel spacing

 

100

GHz

Channel Groups

15216-FLB-2-31.1

59, 58

ITU Ch

15216-FLB-2-32.6

57, 56

ITU Ch

15216-FLB-2-35.0

54, 53

ITU Ch

15216-FLB-2-36.6

52, 51

ITU Ch

15216-FLB-2-38.9

49, 48

ITU Ch

15216-FLB-2-40.5

47, 46

ITU Ch

15216-FLB-2-42.9

44, 43

ITU Ch

15216-FLB-2-44.5

42, 41

ITU Ch

Parameter
Condition
Min
Max
Unit

Channel Groups (continued)

15216-FLB-2-46.9

39, 38

ITU Ch

15216-FLB-2-48.5

37, 36

ITU Ch

15216-FLB-2-50.9

34, 33

ITU Ch

15216-FLB-2-52.5

32, 31

ITU Ch

15216-FLB-2-54.9

29, 28

ITU Ch

15216-FLB-2-56.5

27, 26

ITU Ch

15216-FLB-2-58.9

24, 23

ITU Ch

15216-FLB-2-60.6

22, 21

ITU Ch

Pass-Band

@ 0.5 dB

+/- 0.11

 

nm

Insertion Loss

DROP-COM-RX/ADD-COM-TX to DROP-CH-TX/ADD-CH-RX

1.4

2.5

dB

DROP-COM-RX/ADD-COM-TX to DROP-COM-TX/ADD-COM-RX

0.5

1.6

dB

DROP-COM-RX to MON

15.5

20.5

dB

ADD-COM-RX to MON

15.5

20.5

dB

Isolation

DROP-COM-RX/ADD-COM-TX to any DROP- CH-TX/ADD-COM-RX @ adjacent channels

25

 

dB

DROP-COM-RX/ADD-COM-TX to DROP-COM-TX/ADD-COM-RX @ added/dropped channel wavelengths

14

 

dB

Ripple

Over Pass-Band

 

0.5

dB

Directivity

Any to any DROP-CH- TX/ADD-CH-RX

40

 

dB

Optical Return Loss

Any port

40

 

dB

Polarization Dependent Loss

Any path

 

0.2

dB

Max Optical Power

Any port

 

250

mW

Connector Type

LC

     

A.3 Optical Splitter or Coupler FlexLayer Module Specifications

Table A-3 Optical Splitter or Coupler FlexLayer Module Specifications 

Parameter
Condition
Min
Max
Unit

Operating Wavelength Range

CS-2, CS-3, CS-4

1529

1565

nm

CS-SM-Y1

1260/1430

1360/1580

CS-MM-Y 1

770/1260

860/1380

Insertion Loss

SPL-RX/CPL-TX
to any SPL-TXn/CPL-RXn

1:2/2:1

3.5

4.3

dB

1:3/3:1

5.7

6.6

dB

1:4/4:1

7.3

8.2

dB

1:2&2:1SM

3.4

4.8

dB

1:2&2:1MM

3.4

5.5

CPL-TX to CPL-MON

15.5

20.5

 

SPL-RX to SPL-MON

15.5

20.5

 

Ripple2

Over Pass-Band

 

0.5

dB

Directivity

Any to any SPL-TXn/CPL-RXn

40

 

dB

Optical Return Loss3

Any port

40

 

dB

Polarization Dependent Loss

Any path

1:2/2:1

 

0.25

dB

1:3/3:1

0.3

1:4/4:1

0.4

1:2&2:1

0.25

Max Optical Power

Any port

 

250

mW

Connector Type

LC

       

1 Dual Window

2 For CS-MM-Y: 0.7dB

3 For CS-MM-Y: 25dB


A.4 Four Channel Variable Optical Attenuator (VOA) FlexLayer Module Specifications

Table A-4 Four Channel Optical Variable Attenuator (VOA) FlexLayer Module Specifications 

Parameter
Condition
Min
Max
Unit

Operating Wavelength Range

 

1529

1565

nm

Attenuation Tilt

Attenuation 0 dB

 

0.4

dB

 

Attenuation: 15 dB

 

0.6

dB

 

Attenuation: 30 dB

 

0.8

dB

Attenuation Ripples

Attenuation 0 dB

 

0.35

dB

 

Attenuation 15 dB

 

0.45

dB

 

Attenuation 30 dB

 

0.55

dB

Minimum Insertion loss

   

2.6

dB

Attenuation Range

 

30

 

dB

Number of Turns For 10 dB att

Typical 3 turns

   

dB

Optical Return Loss

 

45

 

dB

Polarization Dependent Loss

Attenuation < 0 dB

 

0.35

dB

 

Attenuation < 15 dB

 

0.5

dB

 

Attenuation < 30 dB

 

0.6

dB

Connector Type

LC

     


hometocprevnextglossaryfeedbacksearchhelp