Contents

Caveats

Hardware Caveats

Software Caveats

New Features

New Hardware Features

New Software Features

Obtaining Documentation

Cisco.com

Documentation CD-ROM

Ordering Documentation

Documentation Feedback

Obtaining Technical Assistance

Cisco.com

Technical Assistance Center

Obtaining Additional Publications and Information


Release Notes for the Cisco ONS 15216 OADM Release 2.2.2


May, 2003

Release notes address closed (maintenance) issues, caveats, and new features for the Cisco ONS 15216 Optical Add/Drop Multiplexer (OADM). For detailed information regarding features, capabilities, hardware, and software introduced with this release, refer to the Cisco ONS 15216 100 GHz OADM Operations Guide, Release 2.2.

Cisco also provides Bug Toolkit, a web resource for tracking defects. To access Bug Toolkit, visit the following URL:

http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl

Contents

Caveats

Hardware Caveats

Software Caveats

Closed Software Caveats

Open Software Caveats

New Features

New Hardware Features

New Software Features

Obtaining Documentation

Obtaining Technical Assistance

Obtaining Additional Publications and Information

Caveats

Review the notes listed below before deploying the ONS 15216. Caveats with DDTS tracking numbers are known system limitations that are scheduled to be addressed in a subsequent release. Caveats without DDTS tracking numbers are provided to point out procedural or situational considerations when deploying the product.

Hardware Caveats

There are no hardware caveats for this release.

Software Caveats

Closed Software Caveats

The following software caveats have been resolved.

DDTS # CSCeb01948: Communications ports lock up after Nessus VxWorks FTP DoS script

While using the remote host, the system can be crashed due to a buffer overflow in FTPD on VxWorks. This vulnerability affects VxWorks FTPD versions 5.4 and 5.4.2. More information can be obtained at http://cgi.nessus.org/plugins/dump.php3?id=11184

Conditions

Although the optical portion of the 15216 OADM is still correctly functioning, the controller board seems to be locked up. Access from ethernet port or RS-232 local craft port are disabled. Alarms will not be surfaced. The only way to recover access to the OADM is to reboot the unit,which will be service affecting.

Workaround

Power cycle to hard reboot the OADM. The issue has been fixed in version 2.2.2

DDTS # CSCea91836: OADM RS232 serial port locks up after user timeout

The user will be automatically logged out when the inactive time is greater than the set timeout period. After the user is logged out, the RS232 port is locked.

Conditions

Occurs when user inactive time is larger than user timeout time or 10 minutes, if the user timeout is set larger than 10 minutes.

Workaround

Open a TL1 session through Ethernet port and issue INIT-SYS::EQPT:123::0; command from the LAN port to restore the RS-232 port communications. The issue takes place in version 2.2.0 and 2.2.1 and has been resolved in version 2.2.2.

DDTS # CSCea16026: OADM unit stops responding to user commands under heavy usage

After a large number of inquiries to OADM, it will stop responding to user commands.

Conditions

Occurs under all conditions.

Workaround

Perform a DC power cycle of the OADM unit if OADM is running software version 2.2.0. Issue has been resolved in software version 2.2.1.

Open Software Caveats

DDTS # CSCdz40833: LOSDROP East-1 alarm enable/disable status is always enabled after a reset

On the 1-ch OADM, the EAST-1 drop port LOS alarm can be disabled, but after a restart of the unit the alarm is displayed again as enabled.

Conditions

Occurs only on the 1-ch OADM EAST-1 drop port when there is a software reset.

Workaround

If the alarm needs to be disabled, use the ED-NE-GEN command again after a reset to disable the alarm.

DDTS # CSCdz40902: Timeout setting is not kept after a restart

The timeout setting is not stored in the non-volatile memory, so if the user changes the timeout value, the new setting is kept if he logs out and then log in again, but is not kept after a restart of the unit (INIT-SYS). After the restart, the values of the timeout are reverted back to the default values (e.g. 15 minutes for RWA users).

Conditions

Occurs for the SET-ATTR-SECUDFLT command if there is a software restart.

Workaround

If the timeout settings are changed from their default values, use the SET-ATTR-SECUDFLT command again after a restart to set the timeout values.

DDTS # CSCdz41745: Alarms/events log file is reset (emptied) after soft or hard reset

The log files of the autonomous messages are not retained if a power cycle or a soft reset (through INIT-SYS) is performed.

Conditions

Occurs if the unit is reset or power cycled.

Workaround

Retrieve the autonomous message log using the RTRV-AO command before resetting or power cycling the unit.

DDTS # CSCdz41689: Date setting unsuccessful if power cycle happens before user logs out

The date/time settings do not take effect if a power cycle happens before the user logs out. Notice that a soft reset (through INIT-SYS) does not have the same impact (after the reset the date and time setting are still kept).

Conditions

Occurs for the ED-DAT command if the unit is power cycled before user log out.

Workaround

If the date or time is edited, the user should log out before power cycling the unit.

DDTS # CSCdx57061: Telnet port 3083 does not require a semicolon after TL1 commands

TL1 commands are sent on the 3083 telnet port when the user hits the enter key - no semicolon is required.

Conditions

This behavior limited to port 3083. Port 3082 correctly requires that a semicolon be used to terminate and send a TL1 command.

Workaround

Commands are correctly sent if the semicolon key is used to terminate the command line.

DDTS # CSCdy63785: Incorrect syntax for RTRV-AO command response

A carriage return and line feed (i.e. a blank line) is missing from RTRV-AO response message, prior to the final " */" before the terminating semicolon.

Conditions

Occurs under all conditions.

Workaround

None. Issue will be resolved in a future software release.

DDTS # CSCdy63840: RTRV-STATUS command should be allowed to any user

Only RWA level users have access to the RTRV-STATUS command.

Conditions

Occurs under all conditions.

Workaround

Log in as a RWA level user to execute the RTRV-STATUS command.

DDTS # CSCdy65043: INH/ALW-MSG-ALL commands should be allowed to any user.

Only RWA and RW level users have access to the INH-MSG-ALL and ALW-MSG-ALL commands.

Conditions

Occurs under all conditions.

Workaround

Log in as a RWA or RW level user to execute the INH-MSG-ALL or ALW-MSG-ALL commands.

DDTS # CSCdy67627: Incorrect filtering implementation for RTRV-ALM-DWDM and RTRV-ALM-COM

The specific parameters used in the stage General Block of the RTRV-ALM-DWDM and RTRV-ALM-COM commands are used as an OR condition instead of an AND condition. For example, after entering RTRV-ALM-DWDM:::123::MN,LOSADD; the response will show alarms of type LOSADD or with severity MN (instead of only those of type LOSADD and with severity MN).

Conditions

Occurs only when more than one parameter is specified in the stage general block.

Workaround

None. Issue will be resolved in a future software release.

DDTS # CSCdy67682: ED-DAT command should be allowed to any user

Only RWA and RW level users have access to the ED-DAT command.

Conditions

Occurs under all conditions.

Workaround

Log in as a RWA or RW level user to execute the ED-DAT command.

DDTS # CSCdx78978: ED-, RTRV-, SET-TH, and RTRV-TH-DWDM take more than two seconds to complete

TL1 commands ED-DWDM, RTRV-DWDM, SET-TH-DWDM, and RTRV-TH-DWDM may sometimes take three to four seconds to complete, without issuing an "in progress" message.

Conditions

Occurs intermittently.

Workaround

None.

DDTS # CSCdy80557: RTRV-DFLT-SECU response message does not display the <aid>

The response message for the RTRV-DFLT-SECU does not include the EQPT <aid>, as per TR-835.

Conditions

Occurs for the RTRV-DFLT-SECU command.

Workaround

None. Issue will be resolved in a future software release.

New Features

This section provides a description of the new features found in ONS 15216, Release 2.2. These are included in the Release 2.2.2 release notes for reference.

New Hardware Features

This section is a high-level overview of the hardware features of ONS 15216, Release 2.2.

One-channel OADM

A one channel OADM is now part of the ONS 15216 product line.

Increased EVOA Accuracy

Improved EVOA accuracy is now 1.04 dB.

New Software Features

This section is a high-level overview of the software features of ONS 15216—Network Release 2.2.

Dual DC Voltage Monitoring

The ONS 15216 OADM now has the capability to individually monitor and alarm the A and B DC voltage feeds.

CALCSETP Function

The addition of the CALCSETP parameter as part of the response to the RTRV-DWDM command provides the user with the ONS 15216's recommended add channel optical power setting based on the optical power of the corresponding drop channel.

Obtaining Documentation

Cisco provides several ways to obtain documentation, technical assistance, and other technical resources. These sections explain how to obtain technical information from Cisco Systems.

Cisco.com

You can access the most current Cisco documentation on the World Wide Web at this URL:

http://www.cisco.com/univercd/home/home.htm

You can access the Cisco website at this URL:

http://www.cisco.com

International Cisco web sites can be accessed from this URL:

http://www.cisco.com/public/countries_languages.shtml

Documentation CD-ROM

Cisco documentation and additional literature are available in a Cisco Documentation CD-ROM package, which is shipped with your product. The Documentation CD-ROM is updated monthly and may be more current than printed documentation. The CD-ROM package is available as a single unit or through an annual subscription.

Ordering Documentation

You can find instructions for ordering documentation at this URL:

http://www.cisco.com/univercd/cc/td/doc/es_inpck/pdi.htm

You can order Cisco documentation in these ways:

Registered Cisco.com users (Cisco direct customers) can order Cisco product documentation from the Networking Products MarketPlace:

http://www.cisco.com/en/US/partner/ordering/index.shtml

Registered Cisco.com users can order the Documentation CD-ROM (Customer Order Number DOC-CONDOCCD=) through the online Subscription Store:

http://www.cisco.com/go/subscription

Nonregistered Cisco.com users can order documentation through a local account representative by calling Cisco Systems Corporate Headquarters (California, U.S.A.) at 408 526-7208 or, elsewhere in North America, by calling 800 553-NETS (6387).

Documentation Feedback

You can submit comments electronically on Cisco.com. On the Cisco Documentation home page, click Feedback at the top of the page.

You can e-mail your comments to bug-doc@cisco.com.

You can submit your comments by mail by using the response card behind the front cover of your document or by writing to the following address:

Cisco Systems
Attn: Customer Document Ordering
170 West Tasman Drive
San Jose, CA 95134-9883

We appreciate your comments.

Obtaining Technical Assistance

Cisco provides Cisco.com, which includes the Cisco Technical Assistance Center (TAC) Website, as a starting point for all technical assistance. Customers and partners can obtain online documentation, troubleshooting tips, and sample configurations from the Cisco TAC website. Cisco.com registered users have complete access to the technical support resources on the Cisco TAC website, including TAC tools and utilities.

Cisco.com

Cisco.com offers a suite of interactive, networked services that let you access Cisco information, networking solutions, services, programs, and resources at any time, from anywhere in the world.

Cisco.com provides a broad range of features and services to help you with these tasks:

Streamline business processes and improve productivity

Resolve technical issues with online support

Download and test software packages

Order Cisco learning materials and merchandise

Register for online skill assessment, training, and certification programs

To obtain customized information and service, you can self-register on Cisco.com at this URL:

http://www.cisco.com

Technical Assistance Center

The Cisco TAC is available to all customers who need technical assistance with a Cisco product, technology, or solution. Two levels of support are available: the Cisco TAC website and the Cisco TAC Escalation Center. The avenue of support that you choose depends on the priority of the problem and the conditions stated in service contracts, when applicable.

We categorize Cisco TAC inquiries according to urgency:

Priority level 4 (P4)—You need information or assistance concerning Cisco product capabilities, product installation, or basic product configuration.

Priority level 3 (P3)—Your network performance is degraded. Network functionality is noticeably impaired, but most business operations continue.

Priority level 2 (P2)—Your production network is severely degraded, affecting significant aspects of business operations. No workaround is available.

Priority level 1 (P1)—Your production network is down, and a critical impact to business operations will occur if service is not restored quickly. No workaround is available.

Cisco TAC Website

You can use the Cisco TAC website to resolve P3 and P4 issues yourself, saving both cost and time. The site provides around-the-clock access to online tools, knowledge bases, and software. To access the Cisco TAC website, go to this URL:

http://www.cisco.com/tac

All customers, partners, and resellers who have a valid Cisco service contract have complete access to the technical support resources on the Cisco TAC website. Some services on the Cisco TAC website require a Cisco.com login ID and password. If you have a valid service contract but do not have a login ID or password, go to this URL to register:

http://tools.cisco.com/RPF/register/register.do

If you are a Cisco.com registered user, and you cannot resolve your technical issues by using the Cisco TAC website, you can open a case online at this URL:

http://www.cisco.com/en/US/support/index.html

If you have Internet access, we recommend that you open P3 and P4 cases through the Cisco TAC website so that you can describe the situation in your own words and attach any necessary files.

Cisco TAC Escalation Center

The Cisco TAC Escalation Center addresses priority level 1 or priority level 2 issues. These classifications are assigned when severe network degradation significantly impacts business operations. When you contact the TAC Escalation Center with a P1 or P2 problem, a Cisco TAC engineer automatically opens a case.

To obtain a directory of toll-free Cisco TAC telephone numbers for your country, go to this URL:

http://www.cisco.com/warp/public/687/Directory/DirTAC.shtml

Before calling, please check with your network operations center to determine the level of Cisco support services to which your company is entitled: for example, SMARTnet, SMARTnet Onsite, or Network Supported Accounts (NSA). When you call the center, please have available your service agreement number and your product serial number.

Obtaining Additional Publications and Information

Information about Cisco products, technologies, and network solutions is available from various online and printed sources.

The Cisco Product Catalog describes the networking products offered by Cisco Systems as well as ordering and customer support services. Access the Cisco Product Catalog at this URL:

http://www.cisco.com/en/US/products/products_catalog_links_launch.html

Cisco Press publishes a wide range of networking publications. Cisco suggests these titles for new and experienced users: Internetworking Terms and Acronyms Dictionary, Internetworking Technology Handbook, Internetworking Troubleshooting Guide, and the Internetworking Design Guide. For current Cisco Press titles and other information, go to Cisco Press online at this URL:

http://www.ciscopress.com

Packet magazine is the Cisco monthly periodical that provides industry professionals with the latest information about the field of networking. You can access Packet magazine at this URL:

http://www.cisco.com/en/US/about/ac123/ac114/about_cisco_packet_magazine.html

iQ Magazine is the Cisco monthly periodical that provides business leaders and decision makers with the latest information about the networking industry. You can access iQ Magazine at this URL:

http://business.cisco.com/prod/tree.taf%3fasset_id=44699&public_view=true&kbns=1.html

Internet Protocol Journal is a quarterly journal published by Cisco Systems for engineering professionals involved in the design, development, and operation of public and private internets and intranets. You can access the Internet Protocol Journal at this URL:

http://www.cisco.com/en/US/about/ac123/ac147/about_cisco_the_internet_protocol_journal.html

Training—Cisco offers world-class networking training, with current offerings in network training listed at this URL:

http://www.cisco.com/en/US/learning/le31/learning_recommended_training_list.html


hometocprevnextglossaryfeedbacksearchhelp

Posted: Sun Apr 2 04:19:32 PDT 2006
All contents are Copyright © 1992--2006 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.