cc/td/doc/product/ong/15216/216oadm
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table Of Contents

TL1 Errors

A.1 Errors

A.1.1 Default Errors


TL1 Errors


This appendix describes the TL1 errors for the Cisco ONS 15216 OADMs.

A.1 Errors

Errors may be generated by any command or command response message. The format of an error message is as follows:

Example A-1

sid date time
M ctag DENY
<errcde>
/* <errmsg> */
;

A.1.1 Default Errors

The Cisco ONS 15216 OADMs generate a set of default errors. Table A-1 lists the default errors for the ONS 15216 OADMs.


Table A-1 Default Errors 

Error Code (errcde)
Error Type
Error Message (errmsg)

EATN

EQUIPAGE

Not Valid for Access Type

ENAD

EQUIPAGE

Not Equipped with Audit Capability

ENAR

EQUIPAGE

Not Equipped with Automatic Reconfiguration

ENDG

EQUIPAGE

Not Equipped with Diagnostic Capability

ENDS

EQUIPAGE

Not Equipped with Duplex Switching

ENEA

EQUIPAGE

Not Equipped with Error Analysis Capability

ENEQ

EQUIPAGE

Not Equipped

ENEX

EQUIPAGE

Not Equipped with Exercise Capability

ENFL

EQUIPAGE

Not Equipped for Fault Locating

ENMD

EQUIPAGE

Not Equipped with Memory Device

ENPM

EQUIPAGE

Not Equipped for Performance Monitoring

ENPS

EQUIPAGE

Not Equipped with Protection Switching

ENRI

EQUIPAGE

Not Equipped for Retrieving Specified Information

ENRS

EQUIPAGE

Not Equipped for Restoration

ENSA

EQUIPAGE

Not Equipped for Scheduling Audit

ENSI

EQUIPAGE

Not Equipped for Setting Specified Information

ENSS

EQUIPAGE

Not Equipped with Synchronization Switching

EQWT

EQUIPAGE

Invalid Parameter, Value

IBEX

INPUT

Block Extra

IBMS

INPUT

Block Missing

IBNC

INPUT

Block Not Consistent

ICNC

INPUT

Command Not Consistent

ICNV

INPUT

Command Not Valid

IDMS

INPUT

Data Missing

IDNC

INPUT

Data Not Consistent

IDNV

INPUT

Data Not Valid

IDRG

INPUT

Data Range Error

IIAC

INPUT

Invalid Access Identifier (AID)

IICM

INPUT

Invalid Command

IICT

INPUT

Invalid Correlation Tag

IIDT

INPUT

Invalid Data Parameter

IIFM

INPUT

Invalid Data Format

IIPG

INPUT

Invalid Parameter Grouping

IISP

INPUT

Invalid Syntax or Punctuation

IITA

INPUT

Invalid Target Indentifier

INAC

INPUT

Invalid Access Number

INDV

STATUS

Invalid AID

INUP

INPUT

Non-Null Unimplemented Parameter

IPEX

INPUT

Parameter Extra

IPMS

INPUT

Parameter Missing

IPNC

INPUT

Parameter Not Consistent

IPNV

INPUT

Parameter Not Valid

ISCH

INPUT

Syntax Invalid Character

ISPC

INPUT

Syntax Punctuation

ITSN

INPUT

Invalid/Inactive Test Session Number

MERR

STATUS

Multiple Error

PICC

PRIVILEGE

Illegal Command Code

PIFC

PRIVILEGE

Illegal Field Code

PIMA

PRIVILEGE

Invalid Memory Address

PIMF

PRIVILEGE

Invalid Memory File

PIRC

PRIVILEGE

Illegal Record Control

PIUC

PRIVILEGE

Illegal User Code

PIUI

PRIVILEGE

Illegal User Identity, Invalid UID

PLNA

PRIVILEGE

Login Not Active

SAAL

STATUS

Already Allowed

SAAS

STATUS

Already Assigned

SABT

STATUS

Aborted

SAIN

STATUS

Already Inhibited

SAIS

STATUS

Already In-Service

SAOP

STATUS

Already Operated

SAPR

STATUS

Already in Protection State

SARB

STATUS

All Resources Busy

SATF

STATUS

Automatic Test Failed

SCNA

STATUS

Command Cannot Be Aborted

SCNF

STATUS

Command Not Found

SDAS

STATUS

Diagnosis Already Started

SDFA

STATUS

Duplex Unit Failed

SDLD

STATUS

Duplex Unit Locked

SDNA

STATUS

Duplex Unit Not Available

SDNC

STATUS

Data Not Consistent

SDNR

STATUS

Data Not Ready

SDNS

STATUS

Diagnosis Not Started Yet

SFAS

STATUS

Fault Locating Already Started

SFNS

STATUS

Fault Locating Not Started yet

SLBM

STATUS

List Below Minimum

SLEM

STATUS

List Exceeds Maximum

SLNS

STATUS

Log Not Started Yet

SNOS

STATUS

NTE is Out-of-Service

SNPR

STATUS

Not in Protection State

SNRM

STATUS

System Not in Restoration Mode

SNSR

STATUS

No Switch Request Outstanding

SNVS

STATUS

Not in Valid State

SPFA

STATUS

Protection Unit Failed

SPLD

STATUS

Protection Unit Locked

SPNA

STATUS

Process Cannot be Aborted

SPNF

STATUS

Process Not Found

SRCI

STATUS

Requested Command(s) Inhibited

SROF

STATUS

Requested Operation Failed

SSRD

STATUS

Switch Request Denied

SSRE

STATUS

System Resources Exceeded

SSTP

STATUS

Stopped

STAB

STATUS

Test Aborted

SVNS

STATUS

Not in Valid State

SWFA

STATUS

Working Unit Failed

SWLD

STATUS

Working Unit Locked



hometocprevnextglossaryfeedbacksearchhelp

Posted: Thu Jul 12 18:13:19 PDT 2007
All contents are Copyright © 1992--2007 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.