Table Of Contents
TL1 Commands
9.1 Introduction
9.2 Connection to the ONS 15216 EDFA2
9.3 Explanation of Command Parameters
9.3.1 Source Identifier (sid) and Target Identifier (tid)
9.3.2 Command Code Modifier (ccm)
9.3.3 Access Identifier (aid)
9.3.4 Correlation Tag (ctag)
9.4 Notation
9.5 Summary of Autonomous Alarms and Messages
9.6 Summary of Security Permissions for TL1 Commands
9.7 TL1 Commands and Autonomous Messages
9.7.1 ACT-USER
9.7.2 ALW-MSG-ALL
9.7.3 APPLY
9.7.4 CANC-USER
9.7.5 COPY-RFILE
9.7.6 CPY-MEM
9.7.7 DLT-RFILE
9.7.8 DLT-USER-SECU
9.7.9 ED-DAT
9.7.10 ED-DWDM
9.7.11 ED-ENV
9.7.12 ED-NE-GEN
9.7.13 ED-PID
9.7.14 ED-USER-SECU
9.7.15 ENT-USER-SECU
9.7.16 INH-MSG-ALL
9.7.17 INIT-SYS
9.7.18 REPT ALM DWDM
9.7.19 REPT ALM ENV
9.7.20 REPT ALM EQPT
9.7.21 REPT EVT DWDM / REPT EVT ENV / REPT EVT EQPT
9.7.22 REPT EVT FXFR
9.7.23 RTRV-ALM-ALL
9.7.24 RTRV-ALM-DWDM
9.7.25 RTRV-ALM-ENV
9.7.26 RTRV-ALM-EQPT
9.7.27 RTRV-AO
9.7.28 RTRV-COND-ALL
9.7.29 RTRV-COND-DWDM
9.7.30 RTRV-COND-ENV
9.7.31 RTRV-COND-EQPT
9.7.32 RTRV-DFLT-SECU
9.7.33 RTRV-DWDM
9.7.34 RTRV-ENV
9.7.35 RTRV-HDR
9.7.36 RTRV-INV
9.7.37 RTRV-NE-GEN
9.7.38 RTRV-RFILE
9.7.39 RTRV-TH-DWDM
9.7.40 RTRV-TH-ENV
9.7.41 RTRV-TH-EQPT
9.7.42 RTRV-TOD
9.7.43 RTRV-USER-SECU
9.7.44 SET-ATTR-SECUDFLT
9.7.45 SET-TH-DWDM
9.7.46 SET-TH-ENV
9.7.47 SET-TH-EQPT
9.7.48 STA-LOCL-RST
TL1 Commands
9.1 Introduction
This chapter provides the details of TL1 commands supported by the Cisco ONS 15216 EDFA2. This chapter also maps various TL1 command parameters to their SNMP counterpart attributes in the ONS 15216 EDFA2 MIB (CERENT-15216-EDFA-MIB.mib).
9.2 Connection to the ONS 15216 EDFA2
The ONS 15216 EDFA2 system supports up to ten simultaneous Telnet connections via the Ethernet LAN port. TL1 sessions are available on TCP/IP port 3082 for raw TL1 and/or port 3083 for TL1 over Telnet. When connected, the ACT-USER command activates a session. (See "Log In via LAN Port Using Telnet (Optional)" section on page 8-3.)
9.3 Explanation of Command Parameters
TL1 messages are grouped into autonomous and non-autonomous types. Autonomous messages are generated as a result of activity on the network elements such as alarms, thresholds, alerts and status information. No request is required in order to receive autonomous messages. Non-autonomous messages consist of a request command and a response from the ONS 15216 EDFA2. Autonomous messages and non-autonomous commands use a common set of parameters. Some of the most common parameters are defined in the following sections.
9.3.1 Source Identifier (sid) and Target Identifier (tid)
The source identifier (sid) or target identifier (tid) parameters uniquely identify an ONS 15216 EDFA2. For the ONS 15216 EDFA2, sid and tid are the same. While the TL1 shell uses the sid/tid name in its command line prompt, the ASH shell uses the host name. The sid/tid name is the same as the sysName in the SNMP MIBs and is displayed in the upper-right of the login screen of the ASH shell.
9.3.2 Command Code Modifier (ccm)
The command code modifier (ccm) identifies the object of the action being applied by the verb of the TL1 command. Some command code modifiers for the ONS 15216 EDFA2 are described in Table 9-1.
Table 9-1 Command Code Modifiers
ccm
|
Description
|
DWDM
|
Optical parameters.
|
ENV
|
Environmental (power bus) parameters.
|
EQPT
|
General parameters of the ONS 15216 EDFA2.
|
INV
|
Inventory parameters.
|
NE-GEN
|
IP communications parameters.
|
9.3.3 Access Identifier (aid)
The access identifier (aid) parameter uniquely identifies an object within the ONS 15216 EDFA2. For the ONS 15216 EDFA2, there are four specific aids (1, PWR-A, PWR-B, EQPT) and the ALL aid, as described in Table 9-2. All autonomous messages identify their specific aid in the message. For all command inputs that require an aid as a mandatory parameter, the ALL aid is accepted as well as any relevant specific aids. If the ALL aid is used in a command, the response contains the appropriate specific aid. For the commands RTRV-ALM-ENV and RTRV-COND-ENV, inputting a specific aid filters the response to information relevant to that aid.
Table 9-2 Access Identifiers
aid
|
Description
|
1
|
Directly affecting the optical signal.
|
PWR-A
|
Affecting Power Bus A (or both A and B).
|
PWR-B
|
Affecting Power Bus B.
|
EQPT
|
General parameters of the ONS 15216 EDFA2 (not directly affecting optical signal or power bus).
|
ALL
|
Any or all of the preceding (command input only).
|
9.3.4 Correlation Tag (ctag)
The correlation tag (ctag) is a unique tag associated with a command. If the user specifies a ctag while entering a command, the response of that command from the ONS 15216 EDFA2 TL1 agent carries the same ctag value. The ctag consists of no more than six alphanumeric characters.
9.4 Notation
The commands described in this document use the symbols shown in Table 9-3 to describe the command format. These symbols are derived from the Telcordia Network Maintenance: Network Element and Transport Surveillance Messages Manual (Generic Requirements, GR-833-CORE).
Table 9-3 TL1 Notation Symbols
Symbol
|
Meaning
|
Description
|
[ ]
|
Optional expression
|
Square brackets indicate the parameters are optional. An optional parameter means that if a user inputs an empty field for an optional parameter, then a default value (or a default action) will be substituted automatically in the transmitted input field. The default value, or null value, is defined in the parameter descriptions of the messages.
|
< >
|
Variable expression
|
Angle brackets enclose one or more variable items in the command line, e.g., <date>, <time>, <aid>, etc.
Italics are used to note variables in paragraph text, e.g., date, time, aid, etc.
|
+
|
More than one time
|
Plus signs indicate that preceding symbol or group of symbols (enclosed in parentheses) may occur one or more times.
|
text
|
Indent of three spaces
|
An indented line indicates an entry of three spaces in the command line.
|
9.5 Summary of Autonomous Alarms and Messages
Table 9-4 summarizes the ONS 15216 EDFA2 autonomous alarms.
Table 9-4 TL1 Autonomous Alarms
TL1 Autonomous Message
|
Condition Type (condtype)
|
Condition Descriptor (conddescr)
|
Access Identifier (aid)
|
Notification Code (ntfcncde)
|
Service Effect (srveff)
|
REPT ALM DWDM1
|
LOS
|
Loss Of Signal (input power)
|
1
|
MJ
|
SA
|
REPT ALM DWDM1
|
GAIN
|
Gain Out Of Range
|
1
|
MJ
|
SA
|
REPT ALM DWDM1
|
LPOUT
|
Loss Of Output Power
|
1
|
MJ
|
SA
|
REPT ALM ENV
|
PWRBUSA
|
Power Bus A (voltage) Alarm
|
PWR-A
|
MN/CR2
|
-
|
REPT ALM ENV
|
PWRBUSB
|
Power Bus B (voltage) Alarm
|
PWR-B
|
MN/CR2
|
-
|
REPT ALM EQPT
|
CTMP
|
Case Temperature Out Of Range
|
EQPT
|
MN
|
NSA
|
REPT ALM EQPT
|
LCRNT1
|
Excessive Pump1 Current
|
EQPT
|
MN
|
NSA
|
REPT ALM EQPT
|
LCRNT2
|
Excessive Pump2 Current
|
EQPT
|
MN
|
NSA
|
REPT ALM EQPT
|
LTMP1
|
Excessive Pump1 Temperature
|
EQPT
|
MN
|
NSA
|
REPT ALM EQPT
|
LTMP2
|
Excessive Pump2 Temperature
|
EQPT
|
MN
|
NSA
|
Table 9-5 summarizes the ONS 15216 EDFA2 autonomous events.
Table 9-5 TL1 Autonomous Events
TL1 Autonomous Message
|
Condition Type (condtype)
|
Condition Descriptor (conddescr)
|
Access Identifier (aid)
|
Condition Effect (condeff)
|
REPT EVT DWDM
|
CTRLMODE1
|
Pump1 Control Mode Changed
|
1
|
TC
|
REPT EVT DWDM
|
CTRLMODE2
|
Pump2 Control Mode Changed
|
1
|
TC
|
REPT EVT DWDM
|
GAINCHGD
|
Overall Gain Changed
|
1
|
TC
|
REPT EVT DWDM
|
LOSHYSTCHGD
|
LOS (loss of signal) Hysteresis Changed
|
1
|
TC
|
REPT EVT DWDM
|
LOSTHCHGD
|
LOS (loss of signal) Threshold Changed
|
1
|
TC
|
REPT EVT DWDM
|
LPOUTCHGD
|
Loss Of Output Power Setpoint Changed
|
1
|
TC
|
REPT EVT DWDM
|
LPOUTDEVCHGD
|
Lpout (loss of output power) Deviation Changed
|
1
|
TC
|
REPT EVT DWDM
|
LPOUTHYSTCHGD
|
Lpout (loss of output power) Hysteresis Changed
|
1
|
TC
|
REPT EVT DWDM
|
PREATTCHGD
|
Pre-attenuation Changed
|
1
|
TC
|
REPT EVT ENV
|
PWRBUSMAXCHGD
|
Power Bus Max (voltage) Changed
|
PWR-A
|
TC
|
REPT EVT ENV
|
PWRBUSMINCHGD
|
Power Bus Min (voltage) Changed
|
PWR-A
|
TC
|
REPT EVT ENV
|
PWRBUSMODE
|
Power Bus Mode Changed
|
PWR-B
|
TC
|
REPT EVT EQPT
|
MAXCTMPCHGD
|
Max Case Temperature Changed
|
EQPT
|
TC
|
REPT EVT EQPT
|
MAXCTMPHYSTCHGD
|
Max Ctmp (case temperature) Hysteresis Changed
|
EQPT
|
TC
|
REPT EVT EQPT
|
MINCTMPCHGD
|
Min Case Temperature Changed
|
EQPT
|
TC
|
REPT EVT EQPT
|
MINCTMPHYSTCHGD
|
Min Ctmp (case temperature) Hysteresis Changed
|
EQPT
|
TC
|
REPT EVT EQPT
|
CUTOVERRESET
|
(Software) Reset After Cutover
|
EQPT
|
TC
|
REPT EVT EQPT
|
SOFTWARELOAD
|
(New) Software Load
|
EQPT
|
TC
|
REPT EVT EQPT
|
SOFTWARERESET
|
Software Reset
|
EQPT
|
TC
|
Table 9-6 summarizes the ONS 15216 EDFA2 file transfer events.
Table 9-6 TL1 Autonomous File Transfer Events
Autonomous TL1 Message
|
File Transfer Status (fxfr_status)
|
File Transfer Result (fxfr_rslt)
|
Access Identifier (aid)
|
REPT EVT FXFR
|
START
|
|
EQPT
|
REPT EVT FXFR
|
COMPLD
|
SUCCESS
|
EQPT
|
FAILURE
|
EQPT
|
Table 9-7 summarizes the ONS 15216 EDFA2 clear alarms.
Table 9-7 TL1 Autonomous Clear Alarms
TL1 Autonomous Message
|
Condition Type (condtype)
|
Condition Descriptor (conddescr)
|
Access Identifier (aid)
|
Notification Code (ntfcncde)
|
Service Effect (srveff)
|
REPT ALM DWDM
|
LOS
|
Loss Of Signal (input power)
|
1
|
CL
|
SA
|
REPT ALM DWDM
|
GAIN
|
Gain Out Of Range
|
1
|
CL
|
SA
|
REPT ALM DWDM
|
LPOUT
|
Loss Of Output Power
|
1
|
CL
|
SA
|
REPT ALM ENV
|
PWRBUSA
|
Power Bus A (voltage) Alarm
|
PWR-A
|
CL
|
-
|
REPT ALM ENV
|
PWRBUSB
|
Power Bus B (voltage) Alarm
|
PWR-B
|
CL
|
-
|
REPT ALM EQPT
|
CTMP
|
Case Temperature Out Of Range
|
EQPT
|
CL
|
NSA
|
REPT ALM EQPT
|
LCRNT1
|
Excessive Pump1 Current
|
EQPT
|
CL
|
NSA
|
REPT ALM EQPT
|
LCRNT2
|
Excessive Pump2 Current
|
EQPT
|
CL
|
NSA
|
REPT ALM EQPT
|
LTMP1
|
Excessive Pump1 Temperature
|
EQPT
|
CL
|
NSA
|
REPT ALM EQPT
|
LTMP2
|
Excessive Pump2 Temperature
|
EQPT
|
CL
|
NSA
|
9.6 Summary of Security Permissions for TL1 Commands
Table 9-8 summarizes the security permissions (access levels) for each available TL1 command and autonomous message.
Table 9-8 TL1 Commands and Messages Security Permissions (Access Levels)
Command or Message
|
Description
|
User Access Levels
|
R
|
RW
|
RWA
|
ACT-USER
|
Activates user session (login). See ACT-USER.
|
Yes
|
Yes
|
Yes
|
ALW-MSG-ALL
|
Allows automatic (REPT) messages. See ALW-MSG-ALL.
|
Yes
|
Yes
|
Yes
|
APPLY
|
Applies software cutover. See APPLY.
|
No
|
No
|
Yes
|
CANC-USER
|
Cancels user session (logoff). See CANC-USER.
|
Yes
|
Yes
|
Yes
|
COPY-RFILE
|
Copies remote or local file to FFS. See COPY-RFILE.
|
No
|
Yes
|
Yes
|
CPY-MEM
|
Copies log file from RAM to FFS. See CPY-MEM.
|
No
|
Yes
|
Yes
|
DLT-RFILE
|
Deletes file from FFS. See DLT-RFILE.
|
No
|
Yes
|
Yes
|
DLT-USER-SECU
|
Deletes a user. See DLT-USER-SECU.
|
No
|
No
|
Yes
|
ED-DAT
|
Edits date and time. See ED-DAT.
|
No
|
No
|
Yes
|
ED-DWDM
|
Edits optical parameters. See ED-DWDM.
|
No
|
Yes
|
Yes
|
ED-ENV
|
Edits power bus mode. See ED-ENV.
|
No
|
Yes
|
Yes
|
ED-NE-GEN
|
Edits general IP-related parameters. See ED-NE-GEN.
|
No
|
Yes
|
Yes
|
ED-PID
|
Edits user password. See ED-PID.
|
Yes (own UID)
|
Yes (own UID)
|
Yes (all UIDs)
|
ED-USER-SECU
|
Edits a user's name and parameters. See ED-USER-SECU.
|
No
|
No
|
Yes
|
ENT-USER-SECU
|
Enters new user. See ENT-USER-SECU.
|
No
|
No
|
Yes
|
INH-MSG-ALL
|
Inhibits some automatic messages. See INH-MSG-ALL.
|
Yes
|
Yes
|
Yes
|
INIT-SYS
|
Initializes (reboots) system. See INIT-SYS.
|
No
|
Yes
|
Yes
|
REPT ALM DWDM
|
Message that reports optical alarm activation/clearing. See REPT ALM DWDM.
|
Yes
|
Yes
|
Yes
|
REPT ALM ENV
|
Message that reports power-bus alarm activation/clearing. See REPT ALM ENV.
|
Yes
|
Yes
|
Yes
|
REPT ALM EQPT
|
Message that reports general alarm activation/clearing. See REPT ALM EQPT.
|
Yes
|
Yes
|
Yes
|
REPT EVT DWDM REPT EVT ENV REPT EVT EQPT
|
Message that reports event logging. See REPT EVT DWDM / REPT EVT ENV / REPT EVT EQPT.
|
Yes
|
Yes
|
Yes
|
REPT EVT FXFR
|
Message that reports FTP file transfer. See REPT EVT FXFR.
|
Yes
|
Yes
|
Yes
|
RTRV-ALM-ALL
|
Retrieves all current alarms. See RTRV-ALM-ALL.
|
Yes
|
Yes
|
Yes
|
RTRV-ALM-DWDM
|
Retrieves current optical alarms. See RTRV-ALM-DWDM.
|
Yes
|
Yes
|
Yes
|
RTRV-ALM-ENV
|
Retrieves current power-bus alarms. See RTRV-ALM-ENV.
|
Yes
|
Yes
|
Yes
|
RTRV-ALM-EQPT
|
Retrieves current general alarms. See RTRV-ALM-EQPT.
|
Yes
|
Yes
|
Yes
|
RTRV-AO
|
Retrieves most-recent autonomous output (REPT) messages. See RTRV-AO.
|
Yes
|
Yes
|
Yes
|
RTRV-COND-ALL
|
Retrieves condition (state) of all current alarms. See RTRV-COND-ALL.
|
Yes
|
Yes
|
Yes
|
RTRV-COND-DWDM
|
Retrieves condition (state) of current optical alarms. See RTRV-COND-DWDM.
|
Yes
|
Yes
|
Yes
|
RTRV-COND-ENV
|
Retrieves condition (state) of current power-bus alarms. See RTRV-COND-ENV.
|
Yes
|
Yes
|
Yes
|
RTRV-COND-EQPT
|
Retrieves condition (state) of current general alarms. See RTRV-COND-EQPT.
|
Yes
|
Yes
|
Yes
|
RTRV-DFLT-SECU
|
Retrieves timeouts for access levels. See RTRV-DFLT-SECU.
|
No
|
No
|
Yes
|
RTRV-DWDM
|
Retrieves optical parameters. See RTRV-DWDM.
|
Yes
|
Yes
|
Yes
|
RTRV-ENV
|
Retrieves power bus mode. See RTRV-ENV.
|
Yes
|
Yes
|
Yes
|
RTRV-HDR
|
Retrieves header (pings NE). See RTRV-HDR.
|
Yes
|
Yes
|
Yes
|
RTRV-INV
|
Retrieves inventory parameters. See RTRV-INV.
|
Yes
|
Yes
|
Yes
|
RTRV-NE-GEN
|
Retrieves general IP-related parameters. See RTRV-NE-GEN.
|
Yes
|
Yes
|
Yes
|
RTRV-RFILE
|
Retrieves files on FFS. See RTRV-RFILE.
|
Yes
|
Yes
|
Yes
|
RTRV-TH-DWDM
|
Retrieves optical thresholds. See RTRV-TH-DWDM.
|
Yes
|
Yes
|
Yes
|
RTRV-TH-ENV
|
Retrieves power-bus thresholds. See RTRV-TH-ENV.
|
Yes
|
Yes
|
Yes
|
RTRV-TH-EQPT
|
Retrieves general thresholds. See RTRV-TH-EQPT.
|
Yes
|
Yes
|
Yes
|
RTRV-TOD
|
Retrieves date and time. See RTRV-TOD.
|
Yes
|
Yes
|
Yes
|
RTRV-USER-SECU
|
Retrieves access level of user(s). See RTRV-USER-SECU.
|
Yes (own UID)
|
Yes (own UID)
|
Yes (all UIDs)
|
SET-ATTR-SECUDFLT
|
Sets timeout values for access levels. See SET-ATTR-SECUDFLT.
|
No
|
No
|
Yes
|
SET-TH-DWDM
|
Sets optical thresholds. See SET-TH-DWDM.
|
No
|
Yes
|
Yes
|
SET-TH-ENV
|
Sets power-bus thresholds. See SET-TH-ENV.
|
No
|
Yes
|
Yes
|
SET-TH-EQPT
|
Sets general thresholds. See SET-TH-EQPT.
|
No
|
Yes
|
Yes
|
STA-LOCL-RST
|
Resets all parameters to manufacturer's default values. See STA-LOCL-RST.
|
No
|
No
|
Yes
|
9.7 TL1 Commands and Autonomous Messages
9.7.1 ACT-USER
Command
ACT-USER
Activates user session (login).
Syntax
ACT-USER:[<tid>]:<uid>:<ctag>::<pid>;
Example 9-1 ACT-USER Command
Amp01:ONS15216 EDFA2> ACT-USER:Amp01:JOE:123::***;
Table 9-9 ACT-USER Syntax Description
Parameter
|
Syntax
|
Description
|
uid
|
string
|
The user's identifier (user name). Can be any combination of up to 10 alphanumeric characters.
|
pid
|
string
|
The user's private identifier (password). The password must be a string of up to 10 characters, where at least 2 are non-alphabetic characters and at least 1 is a special character. Special characters are +, #, and %. (defined in Telcordia GR-831-CORE).
|
9.7.2 ALW-MSG-ALL
Command
ALW-MSG-ALL
Permits or resumes the dispatch of automatic messages from the ONS 15216 EDFA2 that were inhibited by an INH-MSG call. All alarms in existence at the time that this command restores them are transmitted via REPT ALM and REPT EVT messages.
Syntax
ALW-MSG-ALL:[<tid>]::<ctag>::[<ntfcncde>],[<condtype>][,];
Example 9-2 ALW-MSG-ALL Command
Amp01:ONS15216 EDFA2> ALW-MSG-ALL:Amp01::123::MJ,LOS;
Table 9-10 ALW-MSG-ALL Syntax Description
Parameter
|
Syntax
|
Description
|
ntfncde
|
|
Notification code of the alarm or event that is to be allowed (maps to cerent15216EdfaAlarmPriority for active alarms). A null maps to none of the codes, i.e., with a null, all existing ntfncde inhibitions are kept unchanged. Possible values are:
|
CR
|
Critical alarm.
|
MJ
|
Major alarm.
|
MN
|
Minor alarm.
|
NA
|
No alarm.
|
CL
|
Cleared alarm.
|
condtype
|
|
Condition type of the alarm or event that is to be allowed. (Maps to cerent15216EdfaLogEventID.) ALL maps to all types. A null maps to none of the types, i.e., with a null, all existing condtype inhibitions are kept unchanged. Possible condtype and corresponding conddescr (in quotes) are:
|
LOS
|
"Loss of Signal" (input power) alarm (cerent15216EdfaAlarmLpin).
|
GAIN
|
"Gain Out of Range" alarm (cerent15216EdfaAlarmGain).
|
LPOUT
|
"Loss of Output Power" alarm (cerent15216EdfaAlarmLpout).
|
CTMP
|
"Case Temperature Out of Range" alarm (cerent15216EdfaAlarmCtmp).
|
LCRNT1
|
"Excessive Pump1 Current" alarm (cerent15216EdfaAlarmLcrnt1).
|
LCRNT2
|
"Excessive Pump2 Current" alarm (cerent15216EdfaAlarmLcrnt2).
|
LTMP1
|
"Excessive Pump1 Temperature" alarm (cerent15216EdfaAlarmLtmp1).
|
LTMP2
|
"Excessive Pump2 Temperature" alarm (cerent15216EdfaAlarmLtmp2).
|
POWERBUSA
|
"Power Bus A (voltage) Alarm" (cerent15216EdfaAlarmPowerBusA).
|
POWERBUSB
|
"Power Bus B (voltage) Alarm" (cerent15216EdfaAlarmPowerBusB).
|
CTRLMODE1
|
"Pump1 Control Mode Changed" (cerent15216EdfaControlMode for cerent15216EdfaPumpCfgPumpNumber=1).
|
CTRLMODE2
|
"Pump2 Control Mode Changed" (cerent15216EdfaControlMode for cerent15216EdfaPumpCfgPumpNumber=2).
|
|
GAINCHGD
|
"Overall Gain Changed" (cerent15216EdfaConstGainOverallGain).
|
LOSHYSTCHGD
|
"LOS (loss of signal) Hysteresis Changed" (cerent15216EdfaLOSHysteresis).
|
LOSTHCHGD
|
"LOS (loss of signal) Threshold Changed" (cerent15216EdfaLOSThreshold).
|
LPOUTCHGD
|
"Loss of Output Power Setpoint Changed" (cerent15216EdfaLpoutSetpoint).
|
LPOUTDEVCHGD
|
"Lpout (loss of output power) Deviation Changed" (cerent15216EdfaLpoutDeviation).
|
LPOUTHYSTCHGD
|
"Lpout (loss of output power) Hysteresis Changed" (cerent15216EdfaLpoutHysteresis).
|
PREATTCHGD
|
"Pre-attenuation Changed" (cerent15216EdfaVariableGainPreAttenuation).
|
PWRBUSMAXCHGD
|
"Power Bus Max (voltage) Changed" (cerent15216EdfaPowerBusDCVoltageMax).
|
PWRBUSMINCHGD
|
"Power Bus Min (voltage) Changed" (cerent15216EdfaPowerBusDCVoltageMin).
|
PWRBUSMODE
|
"Power Bus Mode Changed" (cerent15216EdfaPowerBusMode).
|
MAXCTMPCHGD
|
"Max Case Temperature Changed" (cerent15216EdfaCtmpMax).
|
MAXCTMPHYSTCHGD
|
"Max Ctmp (case temperature) Hysteresis Changed" (cerent15216EdfaCtmpMaxHysteresis).
|
MINCTMPCHGD
|
"Min Case Temperature Changed" (cerent15216EdfaCtmpMin).
|
MINCTMPHYSTCHGD
|
"Min Ctmp (case temperature) Hysteresis Changed" (cerent15216EdfaCtmpMinHysteresis).
|
CUTOVERRESET
|
(Software) "Reset after Cutover" (cerent15216EdfaOpCutover).
|
SOFTWARELOAD
|
(New) "Software Load" (cerent15216EdfaOpLoad).
|
SOFTWARERESET
|
"Software Reset" (cerent15216EdfaOpReset).
|
ALL
|
All condtype preceding.
|
9.7.3 APPLY
Command
APPLY
Applies a software cutover in the memory. There are two boot file entries. This command exchanges boot file entries 1 and 2 so that when the system is restarted (by the INIT-SYS command), it boots with the image that was (before the execution of this command) at the second entry.
Syntax
APPLY:[<tid>]::<ctag>;
Example 9-3 APPLY Command
Amp01:ONS15216 EDFA2> APPLY:Amp01::1234;
9.7.4 CANC-USER
Command
CANC-USER
Cancels user session (logoff).
Syntax
CANC-USER:[<tid>]:<uid>:<ctag>;
Example 9-4 CANC-USER Command
Amp01:ONS15216 EDFA2> CANC-USER:Amp01:JOE:100;
Table 9-11 CANC-USER Syntax Description
Parameter
|
Syntax
|
Description
|
uid
|
string
|
The user's identifier (user name).
|
9.7.5 COPY-RFILE
Command
COPY-RFILE
Copies a local or remote file to the persistent memory (flash file system) on the ONS 15216 EDFA2. Depending on the value specified for the TYPE parameter, this command can be used to download a remote software image file to the ONS 15216 EDFA2 as its second boot entry (to cutover-upgrade later using the APPLY command), to copy a remote or local file to the ONS 15216 EDFA2 flash file system, or to copy a file on the ONS 15216 EDFA2 flash file system to a remote or local file. There may be a delay while this command executes. See REPT EVT FXFR for information on the autonomous response messages.
Syntax
COPY-RFILE:[<tid>]::<ctag>::TYPE=<type>,SRC=<src>,[DEST=<dest>],[OVERWRITE=<overwrite>];
Example 9-5 COPY-RFILE Command and Response
Amp01:ONS15216 EDFA2> COPY-RFILE:Amp01::1234::TYPE=SWDL,SRC="ftp://user1:passwd@192.168.85
.10:21/bin/15216EdfaSw_2.2.1",DEST="file://localhost/15216EdfaSw_2.2.1",OVERWRITE=YES;
Amp01 2002-04-30 11:34:05
M 100 COMPLD
/* COPY-RFILE */
;
Amp01 2002-04-30 11:34:05
A 7 REPT EVT FXFR
EQPT:15216EdfaSw_2.2.1,START,,
;
Amp01 2002-04-30 11:35:24
A 8 REPT EVT FXFR
EQPT:15216EdfaSw_2.2.1,COMPLD,SUCCESS,1963195
;
Table 9-12 COPY-RFILE Syntax Description
Parameter
|
Syntax
|
Description
|
type
|
|
Specifies the type and direction of transfer. Possible values are:
|
RFR
|
Restore a file from remote server to the ONS 15216 EDFA2's flash file system.
|
RFBU
|
Backup a file from the ONS 15216 EDFA2's flash file system to the remote server (overwrite is always YES for this type).
|
SWDL
|
Download a software image file to the ONS 15216 EDFA2's flash file system and update the second boot entry to point to this file.
|
src, dest
|
string
|
src and dest must both be URLs. Both FTP and file URLs are supported.
An FTP URL has the following format:
ftp:[//[<userid>[:<password>]@]<ftphost>[:<port>]]/<urlpath>
A file URL (referring to the local system) has the following format:
file://localhost/<urlpath>
where
<userid> is the FTP user identifier
<password> is the FTP password for the user
<ftphost> is the IP address of the FTP server
<port> is the port number to connect to
<urlpath> is the path in the following format: <cwd1>/<cwd2>/.../<cwdn>/<filename>
where <cwd1>...<cwdn> are directory levels and <filename> is the file name
|
overwrite
|
|
Possible values are:
|
YES
|
Overwrite existing file of the same name at the destination.
|
NO
|
Do not overwrite if file with same name exists at the destination. This is the default if overwrite is null.
|
9.7.6 CPY-MEM
Command
CPY-MEM
Copies the log file or system configuration file in the non-persistent memory (RAM) or a specified file on the persistent memory (flash file system) to a file with a specified name on the persistent memory.
Syntax
CPY-MEM:[<tid>]::<ctag>::[<fromfile>],[<fromdev>],[<tofile>];
Example 9-6 CPY-MEM Command and Response (Copy LOG File from RAM as aolog.txt on FFS)
Amp01:ONS15216 EDFA2> CPY-MEM:Amp01::123::LOG,MEM,;
Amp01 2002-07-16 09:49:01
M 123 COMPLD
/* CPY-MEM */
;
Example 9-7 CPY-MEM Command and Response (Copy LOG File from RAM as aolog.txt on FFS using Null)
Amp01:ONS15216 EDFA2> CPY-MEM:Amp01::123::,,;
Amp01 2002-07-16 09:46:01
M 123 COMPLD
/* CPY-MEM */
;
Example 9-8 CPY-MEM Command and Response (Copy aolog.txt on FFS as logfile20020716.txt on FFS)
Amp01:ONS15216 EDFA2> CPY-MEM:Amp01::123::aolog.txt,FFS,logfile20020716;
Amp01 2002-07-16 09:50:38
M 123 COMPLD
/* CPY-MEM */
;
Table 9-13 CPY-MEM Syntax Description
Parameter
|
Syntax
|
Description
|
fromfile
|
|
Name of the source file. A null means LOG. Can be null only when fromdev is also null.
|
CFG
|
ONS 15216 EDFA2 system configuration file, only when fromdev is specified to be DBCFG or null.
|
LOG
|
ONS 15216 EDFA2 system log file, only when fromdev is specified to be MEM or null.
|
any other string
|
The name of the source file when fromdev is specified to be FFS. If fromdev is specified to be MEM or null, any string other than LOG is invalid.
File names are case sensitive.
|
fromdev
|
|
Device on which the source file exists. A null means MEM. Possible values are:
|
DBCFG
|
ONS 15216 EDFA2 configuration parameters from IDROM, CFGROM, RAM, and FFS.
|
MEM
|
ONS 15216 EDFA2 non-persistent memory (RAM).
|
FFS
|
ONS 15216 EDFA2 persistent memory (flash file system).
|
tofile
|
CFG
|
ONS 15216 EDFA2 system configuration in memory.
The system must be rebooted using INI-SYS for changes to the system configuration to take effect.
|
any other string
|
The name string of the destination file. A null value is valid only when fromfile is LOG or null and fromdev is MEM or null. When null is valid, the system log file (LOG) is saved as aolog.txt.
File names are case sensitive.
If copying from RAM (MEM) and the destination file name already exists, the destination file is overwritten. If copying from FFS and the destination file name already exists, the execution fails.
|
9.7.7 DLT-RFILE
Command
DLT-RFILE
Deletes a file from the flash file system (FFS) of the ONS 15216 EDFA2.
Syntax
DLT-RFILE:[<tid>]::<ctag>::FILE=<localfilename>;
Example 9-9 DLT-RFILE Command
Amp01:ONS15216 EDFA2> DLT-RFILE:Amp01::1234::FILE=snmp.cfg;
Table 9-14 DLT-RFILE Syntax Description
Parameter
|
Syntax
|
Description
|
localfilename
|
string
|
Name of the file on the flash file system of the ONS 15216 EDFA2 that is to be deleted. File names are case sensitive.
|
9.7.8 DLT-USER-SECU
Command
DLT-USER-SECU
Deletes (removes) an existing user from the system.
Syntax
DLT-USER-SECU:[<tid>]:<uid>:<ctag>;
Example 9-10 DLT-USER-SECU Command
Amp01:ONS15216 EDFA2> DLT-USER-SECU:Amp01:jsmith:123;
Table 9-15 DLT-USER-SECU Syntax Description
Parameter
|
Syntax
|
Description
|
uid
|
string
|
The user identifier (user name) of the existing user to be removed.
|
9.7.9 ED-DAT
Command
ED-DAT
Edits the date and/or time of the ONS 15216 EDFA2.
Syntax
ED-DAT:[<tid>]::<ctag>::<utcdate>,<utctime>;
Example 9-11 ED-DAT Command
Amp01:ONS15216 EDFA2> ED-DAT:Amp01::123::2001-12-18,02-24-55;
Table 9-16 ED-DAT Syntax Description
Parameter
|
Syntax
|
Description
|
utcdate
|
yyyy-mm-dd
|
Change date to this value in universal coordinated time (UTC), which is the same as Greenwich Mean Time (GMT) Modifies cerent15216EdfaRtcDateAndTimeGMTString. Can not be null if utctime is also null.
|
utctime
|
hh-mm-ss
|
Change time to this value in universal coordinated time (UTC), which is the same as Greenwich Mean Time (GMT). (A time zone can not be set using TL1.) Modifies cerent15216EdfaRtcDateAndTimeGMTString. Can not be null if utcdate is also null.
|
9.7.10 ED-DWDM
Command
ED-DWDM
Configures the ONS 15216 EDFA2 optical control parameters.
Syntax
ED-DWDM:[<tid>]:<aid>:<ctag>:::[PUMP1CTRLMODE=<pump1ctrlmode>],[PUMP1CTRLVALUE=<pump1ctrlv
alue>],[PUMP2CTRLMODE=<pump2ctrlmode>],[PUMP2CTRLVALUE=<pump2ctrlvalue>],[OVERALLGAIN=<gai
n>],[PREATT=<preatt>];
Example 9-12 ED-DWDM Command
Amp01:ONS15216 EDFA2> ED-DWDM:Amp01:ALL:123:::PUMP1CTRLMODE=GAINTEMP;
Table 9-17 ED-DWDM Syntax Description
Parameter
|
Syntax
|
Description
|
aid
|
1
ALL
|
1 and ALL have same input effect.
|
pump1ctrlmode, pump2ctrlmode
|
|
Pump 1 or pump 2 control mode (maps to cerent15216EdfaPumpCfgControlMode for the corresponding pump). Generally, pump1ctrlmode and pump2ctrlmode must be the same value. One exception is OPWR which is not valid for pump 1 and can only be set for pump 2. Possible values are:
|
GAINTEMP
|
Constant Gain Temperature Compensated mode (manufacturer default) (cerent15216EdfaPumpCfgControlMode set to constGainTempComp). If one pump is set to GAINTEMP, the other pump automatically gets set to GAINTEMP also.
|
OPWR
|
Constant Output Power mode (cerent15216EdfaPumpCfgControlMode set to constOutputPower). This is not a valid mode for pump 1. If pump 2 is set to OPWR, pump 1 gets automatically set to PWR with a value of 75 mW.
|
CRNT
|
Constant Pump Current mode (cerent15216EdfaPumpCfgControlMode set to constCurrent). Must set pump 1 and pump 2 to this mode at the same time.
|
PWR
|
Constant Pump Power mode (cerent15216EdfaPumpCfgControlMode set to constPower). Must set Pump 1 and Pump 2 to this mode at the same time.
|
IDLE
|
Pump is shut down (cerent15216EdfaPumpCfgControlMode set to idle).
|
pump1ctrlvalue, pump2ctrlvalue
|
|
Pump 1 or pump 2 control value. This value's interpretation depends on the control mode of the corresponding pump. Command fails if control mode is GAINTEMP. Possible values are:
|
0 - 650
|
Output power in units of 10 mW when mode is OPWR (sets cerent15216EdfaPumpCfgConstOutPower). The default value is 0.
|
0 - 300
|
Current value in mA when mode is CRNT (sets cerent15216EdfaPumpCfgConstPumpCurrent). The default value is 0. Must set pump 1 and pump 2 at the same time.
|
0 - 100
|
Pump power in mW when mode is PWR (sets cerent15216EdfaPumpCfgConstPumpPower). The default value is 0. Must set pump 1 and pump 2 at the same time.
|
gain
|
130 - 220
|
Value of gain in units of 10 dB when mode is GAINTEMP (sets cerent15216EdfaConstGainOverallGain). The command fails if in other modes.
|
preatt
|
10 - 100
|
Gain pre-attenuation value in units of 10 dB when mode is other than GAINTEMP (sets cerent15216EdfaVariableGainPreAttenuation).
|
9.7.11 ED-ENV
Command
ED-ENV
Configures the ONS 15216 EDFA2 environmental (power bus) parameters.
Syntax
ED-ENV:[<tid>]:<aid>:<ctag>:::PWRBUSMODE=<pwrbusmode>;
Example 9-13 ED-ENV Command
Amp01:ONS15216 EDFA2> ED-ENV:Amp01:ALL:123:::PWRBUSMODE=SIMPLEX;
Table 9-18 ED-ENV Syntax Description
Parameter
|
Syntax
|
Description
|
aid
|
PWR-A
PWR-B
ALL
|
PWR-A, PWR-B, and ALL have same input effect.
|
pwrbusmode
|
|
Power bus mode. Possible values are:
|
SIMPLEX
|
Simplex mode. Requires power only to bus A. Sets cerent15216EdfaPowerBusMode to simplex.
|
DUPLEX
|
Duplex mode (default). Requires power to both bus A and bus B. Sets cerent15216EdfaPowerBusMode to duplex.
|
9.7.12 ED-NE-GEN
Command
ED-NE-GEN
Edit general parameters of the ONS 15216 EDFA2. Edits ONS 15216 EDFA2's sid (source identifier)/tid (target identifier), IP address, IP mask, and IP address of the default router. The ONS 15216 EDFA2 needs to be manually rebooted for the changes to take effect. (Use the INIT-SYS command to manually reboot after changing parameters.) Also edits the boot table content: to return to the TL1 shell from the ASH shell, use the ASH command shell type modify tl1 (step 3. in "Log In via RS-232 (EIA/TIA-232) Port Using HyperTerminal" section on page 8-1).
Syntax
ED-NE-GEN:[<tid>]::<ctag>:::[NAME=<name>],[IPADDR=<ipaddr>],[IPMASK=<ipmask>],[DEFRTR=<def
rtr>],[BOOTRECORDTYPE1=<bootrectype1>],[BOOTFILENAME1=<bootfilename1>],[BOOTIPADDR1=<booti
paddr1>],[BOOTRECORDTYPE2=<bootrectype2>],[BOOTFILENAME2=<bootfilename2>],[BOOTIPADDR2=<bo
otipaddr2>],[CLI=<cli>];
Example 9-14 ED-NE-GEN Command
Amp01:ONS15216 EDFA2> ED-NE-GEN:Amp01::123:::NAME=Amp01,IPADDR=192.167.3.4,IPMASK=255.255.
255.0,DEFRTR=192.167.3.20,BOOTRECORDTYPE2=TFTP,BOOTFILENAME2=15216EdfaSw_1.4.0,BOOTIPADDR2
=192.168.3.4,CLI=ASH;
Table 9-19 ED-NE-GEN Syntax Description
Parameter
|
Syntax
|
Description
|
name
|
string
|
System's sid/tid name (sysName).
|
ipaddr
|
string
|
IP address of the system (cerent15216EdfaSromIpMgmtEnetAddress).
|
ipmask
|
string
|
Subnet mask of the system (cerent15216EdfaSromIpMgmtEnetSubNetMask).
|
defrtr
|
string
|
IP address of the default router (cerent15216EdfaSromIpMgmtDefaultRouterAddress).
|
bootrectype1
|
|
Boot record type (cerent15216EdfaBootType for first entry). Possible values are:
|
FLASH
|
Boot from flash.
|
TFTP
|
Boot through TFTP.
|
bootfilename1
|
string
|
Boot file name (cerent15216EdfaBootFileName for first entry). File names are case sensitive.
|
bootipaddr1
|
string
|
IP address to boot from if bootrectype1 is set to TFTP (cerent15216EdfaBootIpAddress for first entry).
|
bootrectype2
|
|
Boot record type (cerent15216EdfaBootType for second entry). Possible values are:
|
FLASH
|
Boot from flash.
|
TFTP
|
Boot through TFTP.
|
bootfilename2
|
string
|
Boot file name (cerent15216EdfaBootFileName for second entry). File names are case sensitive.
|
bootipaddr2
|
string
|
IP address to boot from if bootrectype2 is set to TFTP (cerent15216EdfaBootIpAddress for second entry).
|
cli
|
|
Default type of command line interface for all EIA/TIA-232 and default telnet port user sessions with the ONS 15216 EDFA2. Possible values are:
|
TL1
|
TL1shell interface (manufacturer default).
|
ASH
|
ASH shell interface - ONS 15216 EDFA2's native interface.
|
9.7.13 ED-PID
Command
ED-PID
Edits password.
Syntax
ED-PID:[<tid>]:<uid>:<ctag>::<oldpid>,<newpid>;
Example 9-15 ED-PID Command
Amp01:ONS15216 EDFA2> ED-PID:Amp01:JOE:123::OLDPW,NEWPW;
Table 9-20 ED-PID Syntax Description
Parameter
|
Syntax
|
Description
|
uid
|
string
|
The user's identifier (user name).
|
oldpid
|
string
|
The user's old password.
|
newpid
|
string
|
The user's new private identifier (password). Must be a string of up to 10 characters, where at least 2 are non-alphabetic characters and at least 1 is a special character. Special characters are +, #, and %. (defined in Telcordia GR-831-CORE).
|
9.7.14 ED-USER-SECU
Command
ED-USER-SECU
Edits the user identifier, password and access level of an existing user. Per TR-835, only those data parameters that are to be edited are entered while those that are unaffected are omitted. If any position-defined parameter is omitted, a comma is to be used as the delimiter.
Syntax
ED-USER-SECU:[<tid>]:<uid>:<ctag>::<newuid>,<pid>,,<al>[:];
Example 9-16 ED-USER-SECU Command
Amp01:ONS15216 EDFA2> ED-USER-SECU:Amp01:jsmith:123::johnsmith,****,,RW;
Table 9-21 ED-USER-SECU Syntax Description
Parameter
|
Syntax
|
Description
|
uid
|
string
|
The user identifier (user name) of the existing user whose parameters are being modified.
|
newuid
|
string
|
New user identifier (user name) for the existing user. Can be any combination of up to 10 alphanumeric characters.
|
pid
|
string
|
The user's new private identifier (password). Must be a string of up to 10 characters, where at least 2 are non-alphabetic characters and at least 1 is a special character. Special characters are +, #, and %. (defined in Telcordia GR-831-CORE).
|
al
|
|
New access level of the user. See "Summary of Security Permissions for TL1 Commands" section for access level permissions.
|
R
|
Read only privileges.
|
RW
|
Read and write privileges.
|
RWA
|
Read, write, and administrative privileges.
|
9.7.15 ENT-USER-SECU
Command
ENT-USER-SECU
Creates a new user in the system; specifies the user identifier, password and access level of the new user.
Syntax
ENT-USER-SECU:[<tid>]:<uid>:<ctag>::<pid>,,<al>[:];
Example 9-17 ENT-USER-SECU Command
Amp01:ONS15216 EDFA2> ENT-USER-SECU:Amp01:jsmith:123::****,,RW;
Table 9-22 ENT-USER-SECU Syntax Description
Parameter
|
Syntax
|
Description
|
uid
|
string
|
The user identifier (user name) of the new user being created. Can be any combination of up to 10 alphanumeric characters.
|
pid
|
string
|
The user's private identifier (password). Must be a string of up to 10 characters, where at least 2 are non-alphabetic characters and at least 1 is a special character. Special characters are +, #, and %. (defined in Telcordia GR-831-CORE).
|
al
|
|
Access level of the user. See "Summary of Security Permissions for TL1 Commands" section for access level permissions.
|
R
|
Read only privileges.
|
RW
|
Read and write privileges.
|
RWA
|
Read, write, and administrative privileges.
|
9.7.16 INH-MSG-ALL
Command
INH-MSG-ALL
Prohibits the dispatch of some automatic messages from the ONS 15216 EDFA2 as specified in the parameters. Does not affect response from RTRV commands.
Syntax
INH-MSG-ALL:[<tid>]::<ctag>::[<ntfcncde>],[<condtype>][,];
Example 9-18 INH-MSG-ALL Command
Amp01:ONS15216 EDFA2> INH-MSG-ALL:Amp01::123::MJ,LOS;
Table 9-23 INH-MSG-ALL Syntax Description
Parameter
|
Syntax
|
Description
|
ntfncde
|
|
Notification code of the alarm or event that is to be allowed (maps to cerent15216EdfaAlarmPriority for active alarms). A null maps to none of the codes, i.e., with a null, all existing ntfncde inhibitions are kept unchanged. Possible values are:
|
CR
|
Critical alarm.
|
MJ
|
Major alarm.
|
MN
|
Minor alarm.
|
NA
|
No alarm.
|
CL
|
Cleared alarm.
|
condtype
|
|
Condition type of the alarm or event that is to be inhibited (maps to cerent15216EdfaLogEventID). ALL maps to all types. A null maps to none of the types, i.e., with a null, all existing condtype allowances are kept unchanged. Possible condtype and corresponding conddescr (in quotes) are:
|
LOS
|
"Loss of Signal" (input power) alarm (cerent15216EdfaAlarmLpin).
|
GAIN
|
"Gain Out of Range" alarm (cerent15216EdfaAlarmGain).
|
LPOUT
|
"Loss of Output Power" alarm (cerent15216EdfaAlarmLpout).
|
CTMP
|
"Case Temperature Out of Range" alarm (cerent15216EdfaAlarmCtmp).
|
LCRNT1
|
"Excessive Pump1 Current" alarm (cerent15216EdfaAlarmLcrnt1).
|
LCRNT2
|
"Excessive Pump2 Current" alarm (cerent15216EdfaAlarmLcrnt2).
|
LTMP1
|
"Excessive Pump1 Temperature" alarm (cerent15216EdfaAlarmLtmp1).
|
LTMP2
|
"Excessive Pump2 Temperature" alarm (cerent15216EdfaAlarmLtmp2).
|
POWERBUSA
|
"Power Bus A (voltage) Alarm" (cerent15216EdfaAlarmPowerBusA).
|
POWERBUSB
|
"Power Bus B (voltage) Alarm" (cerent15216EdfaAlarmPowerBusB).
|
CTRLMODE1
|
"Pump1 Control Mode Changed" (cerent15216EdfaControlMode for cerent15216EdfaPumpCfgPumpNumber=1).
|
CTRLMODE2
|
"Pump2 Control Mode Changed" (cerent15216EdfaControlMode for cerent15216EdfaPumpCfgPumpNumber=2).
|
|
GAINCHGD
|
"Overall Gain Changed" (cerent15216EdfaConstGainOverallGain).
|
LOSHYSTCHGD
|
"LOS (loss of signal) Hysteresis Changed" (cerent15216EdfaLOSHysteresis).
|
LOSTHCHGD
|
"LOS (loss of signal) Threshold Changed" (cerent15216EdfaLOSThreshold).
|
LPOUTCHGD
|
"Loss of Output Power Setpoint Changed" (cerent15216EdfaLpoutSetpoint).
|
LPOUTDEVCHGD
|
"Lpout (loss of output power) Deviation Changed" (cerent15216EdfaLpoutDeviation).
|
LPOUTHYSTCHGD
|
"Lpout (loss of output power) Hysteresis Changed" (cerent15216EdfaLpoutHysteresis).
|
PREATTCHGD
|
"Pre-attenuation Changed" (cerent15216EdfaVariableGainPreAttenuation).
|
PWRBUSMAXCHGD
|
"Power Bus Max (voltage) Changed" (cerent15216EdfaPowerBusDCVoltageMax).
|
PWRBUSMINCHGD
|
"Power Bus Min (voltage) Changed" (cerent15216EdfaPowerBusDCVoltageMin).
|
PWRBUSMODE
|
"Power Bus Mode Changed" (cerent15216EdfaPowerBusMode).
|
MAXCTMPCHGD
|
"Max Case Temperature Changed" (cerent15216EdfaCtmpMax).
|
MAXCTMPHYSTCHGD
|
"Max Ctmp (case temperature) Hysteresis Changed" (cerent15216EdfaCtmpMaxHysteresis).
|
MINCTMPCHGD
|
"Min Case Temperature Changed" (cerent15216EdfaCtmpMin).
|
MINCTMPHYSTCHGD
|
"Min Ctmp (case temperature) Hysteresis Changed" (cerent15216EdfaCtmpMinHysteresis).
|
CUTOVERRESET
|
(Software) "Reset after Cutover" (cerent15216EdfaOpCutover).
|
SOFTWARELOAD
|
(New) "Software Load" (cerent15216EdfaOpLoad).
|
SOFTWARERESET
|
"Software Reset" (cerent15216EdfaOpReset).
|
ALL
|
All condtype preceding.
|
9.7.17 INIT-SYS
Command
INIT-SYS
Reboots the system.
Syntax
INIT-SYS:[<tid>]:<aid>:<ctag>::<ph>;
Example 9-19 INIT-SYS Command
Amp01:ONS15216 EDFA2> INIT-SYS:Amp01:ALL:1234::1;
Table 9-24 INIT-SYS Syntax Description
Parameter
|
Syntax
|
Description
|
aid
|
string
EQPT
ALL
|
EQPT and ALL have same input effect.
|
ph
|
integer
1
|
Level of initialization. Always 1.
|
9.7.18 REPT ALM DWDM
Command
REPT ALM DWDM
Reports when a DWDM alarm is logged or cleared (derived from cerent15216EdfaAlarmState).
Note The REPT ALM DWDM messages for Loss of Signal, Gain Out of Range, and Loss of Output Power are prioritized (in the order just listed) so that only one message can be delivered at one time. For example, if the ONS 15216 EDFA2 detects both a loss of input signal and a loss of output power at the same time, it will deliver only the Loss of Signal message to the user. This prioritized filtering of alarms does not occur with the SNMP delivery of alarms of the ONS 15216 EDFA2.
Syntax
<sid> <date> <time>
<almcde> <atag> REPT ALM DWDM
"<aid>:<ntfcncde>,<condtype>,<srveff>,<ocrdat>,<ocrtm>,,:<conddescr>"
;
Example 9-20 REPT ALM DWDM Message
Amp01 2001-06-18 14:50:44
** 142 REPT ALM DWDM
"1:MJ,LOS,SA,6-18,14-50-44,,:\"Loss Of Signal\""
;
Table 9-25 REPT ALM DWDM Syntax Description
Parameter
|
Syntax
|
Description
|
time
|
hh:mm:ss
|
Time of origination of TL1 message.
|
almcde
|
|
The alarm severity code for the TL1 message. Possible values are:
|
*C
|
Critical alarm.
|
**
|
Major alarm.
|
*
|
Minor alarm.
|
A
|
No alarm. Occurs only when ntfncde is NA.
|
atag
|
0 - 999
|
An integer between 0 and 999 used as a sequence number in autonomous messages.
|
aid
|
|
Always 1.
|
1
|
Directly affecting the optical signal.
|
conddescr
|
|
Detailed text description of the event. The conddescr is 1 to 64 characters of ASCII text. See condtype below.
|
condtype
|
|
Condition type identifies the type of alarm (maps to cerent15216EdfaLogEventID). Possible condtype and corresponding conddescr (in quotes) are:
|
LOS
|
"Loss of Signal" (input power) alarm (cerent15216EdfaAlarmLpin).
|
GAIN
|
"Gain Out of Range" alarm (cerent15216EdfaAlarmGain).
|
LPOUT
|
"Loss of Output Power" alarm (cerent15216EdfaAlarmLpout).
|
date
|
yyyy-mm-dd
|
Date of origination of TL1 message.
|
ntfncde
|
|
Notification code (maps to cerent15216EdfaAlarmPriority). Possible values are:
|
CR
|
Critical alarm.
|
MJ
|
Major alarm.
|
MN
|
Minor alarm.
|
CL
|
Cleared alarm.
|
NA
|
No alarm.
|
ocrdat
|
m-d
|
Date (month-day) of the event occurrence (derived from cerent15216EdfaDateAndTimeString).
|
ocrtm
|
h-m-s
|
Time (hour-minute-second) of the event occurrence (derived from cerent15216EdfaDateAndTimeString).
|
sid
|
string
|
Source identifier uniquely identifies the source of a TL1 autonomous command.
|
srveff
|
|
Effect on service. Possible values are:
|
SA
|
Service affecting.
|
NSA
|
Non-service affecting.
|
9.7.19 REPT ALM ENV
Command
REPT ALM ENV
Reports when a power bus alarm is logged or cleared (derived from cerent15216EdfaAlarmState).
Syntax
<sid> <date> <time>
<almcde> <atag> REPT ALM ENV
"<aid>:<ntfcncde>,<condtype>,<ocrdat>,<ocrtm>,<conddescr>"
;
Example 9-21 REPT ALM ENV Message
Amp01 2001-06-18 14:48:44
** 141 REPT ALM ENV
"PWR-A:MN,PWRBUSA,6-18,14-48-44,\"Power Bus A Alarm\""
;
Table 9-26 REPT ALM ENV Syntax Description
Parameter
|
Syntax
|
Description
|
almcde
|
|
The alarm severity code for the TL1 message. Possible values are:
|
*C
|
Critical alarm.
|
**
|
Major alarm.
|
*
|
Minor alarm.
|
A
|
No alarm. Occurs only when ntfncde is NA.
|
atag
|
0 - 999
|
An integer between 0 and 999 used as a sequence number in autonomous messages .
|
aid
|
|
Possible values are:
|
PWR-A
|
Affecting Power Bus A (or both A and B).
|
PWR-B
|
Affecting Power Bus B.
|
conddescr
|
|
Detailed text description of the event. The conddescr is 1 to 64 characters of ASCII text. See condtype below.
|
condtype
|
|
Condition type identifies the type of alarm (maps to cerent15216EdfaLogEventID). Possible condtype and corresponding conddescr (in quotes) are:
|
PWRBUSA
|
"Power Bus A (voltage) Alarm" (cerent15216EdfaAlarmPowerBusA).
|
PWRBUSB
|
"Power Bus B (voltage) Alarm" (cerent15216EdfaAlarmPowerBusB).
|
date
|
yyyy-mm-dd
|
Date of origination of TL1 message.
|
ntfncde
|
|
Notification code (maps to cerent15216EdfaAlarmPriority). Possible values are:
|
CR
|
Critical alarm.
|
MJ
|
Major alarm.
|
MN
|
Minor alarm.
|
CL
|
Cleared alarm.
|
NA
|
No alarm.
|
ocrdat
|
m-d
|
Date (month-day) of the event occurrence (derived from cerent15216EdfaDateAndTimeString).
|
ocrtm
|
h-m-s
|
Time (hour-minute-second) of the event occurrence (derived from cerent15216EdfaDateAndTimeString).
|
sid
|
string
|
Source identifier uniquely identifies the source of a TL1 autonomous command.
|
time
|
hh:mm:ss
|
Time of origination of TL1 message.
|
9.7.20 REPT ALM EQPT
Command
REPT ALM EQPT
Reports when a general alarm (not directly affecting optical signal or power bus) is logged or cleared (derived from cerent15216EdfaAlarmState).
Syntax
<sid> <date> <time>
<almcde> <atag> REPT ALM EQPT
"<aid>:<ntfcncde>,<condtype>,<srveff>,<ocrdat>,<ocrtm>,,:<conddescr>"
;
Example 9-22 REPT ALM EQPT Message
Amp01 2001-06-18 14:48:44
* 141 REPT ALM EQPT
"EQPT:MN,LCRNT1,NSA,6-18,14-48-44,,:\"Excessive Pump1 Current\""
;
Table 9-27 REPT ALM EQPT Syntax Description
Parameter
|
Syntax
|
Description
|
almcde
|
|
The alarm severity code for the TL1 message. Possible values are:
|
*C
|
Critical alarm.
|
**
|
Major alarm.
|
*
|
Minor alarm.
|
A
|
No alarm. Occurs only when ntfncde is NA.
|
atag
|
0 - 999
|
An integer between 0 and 999 used as a sequence number in autonomous messages .
|
aid
|
|
Always EQPT.
|
EQPT
|
General parameters of the ONS 15216 EDFA2 (not directly affecting optical signal or power bus).
|
conddescr
|
|
Detailed text description of the event. The conddescr is 1 to 64 characters of ASCII text. See condtype below.
|
condtype
|
|
Condition type identifies the type of alarm (maps to cerent15216EdfaLogEventID). Possible condtype and corresponding conddescr (in quotes) are:
|
CTMP
|
"Case Temperature Out of Range" alarm (cerent15216EdfaAlarmCtmp).
|
LCRNT1
|
"Excessive Pump1 Current" alarm (cerent15216EdfaAlarmLcrnt1).
|
LCRNT2
|
"Excessive Pump2 Current" alarm (cerent15216EdfaAlarmLcrnt2).
|
LTMP1
|
"Excessive Pump1 Temperature" alarm (cerent15216EdfaAlarmLtmp1).
|
LTMP2
|
"Excessive Pump2 Temperature" alarm (cerent15216EdfaAlarmLtmp2).
|
date
|
yyyy-mm-dd
|
Date of origination of TL1 message.
|
ntfncde
|
|
Notification code (maps to cerent15216EdfaAlarmPriority). Possible values are:
|
CR
|
Critical alarm.
|
MJ
|
Major alarm.
|
MN
|
Minor alarm.
|
CL
|
Cleared alarm.
|
NA
|
No alarm.
|
ocrdat
|
m-d
|
Date (month-day) of the event occurrence (derived from cerent15216EdfaDateAndTimeString).
|
ocrtm
|
h-m-s
|
Time (hour-minute-second) of the event occurrence (derived from cerent15216EdfaDateAndTimeString).
|
sid
|
string
|
Source identifier uniquely identifies the source of a TL1 autonomous command.
|
srveff
|
|
Effect on service. Possible values are:
|
SA
|
Service affecting.
|
NSA
|
Non-service affecting.
|
time
|
hh:mm:ss
|
Time of origination of TL1 message.
|
9.7.21 REPT EVT DWDM / REPT EVT ENV / REPT EVT EQPT
Command
REPT EVT DWDM or REPT EVT ENV or REPT EVT EQPT
Reports autonomous events. Reports when an event is logged.
Syntax
<sid> <date> <time>
A <atag> REPT EVT <ccm>
"<aid>:<condtype>,<condeff>,<ocrdat>,<ocrtm>,,,,:<conddescr>"
;
Example 9-23 REPT EVT DWDM Message
Amp01 2001-06-18 14:48:44
A 141 REPT EVT DWDM
"1:CTRLMODE1,TC,6-18,14-48-44,,,,:\"Pump1 Control Mode Changed\""
;
Table 9-28 REPT EVT DWDM / REPT EVT ENV / REPT EVT EQPT Syntax Description
Parameter
|
Syntax
|
Description
|
atag
|
0 - 999
|
An integer between 0 and 999 used as a sequence number in autonomous messages .
|
aid
|
|
Possible values are:
|
1
|
Directly affecting the optical signal.
|
PWR-A
|
Affecting Power Bus A (or both A and B).
|
PWR-B
|
Affecting Power Bus B.
|
EQPT
|
General parameters of the ONS 15216 EDFA2 (not directly affecting optical signal or power bus).
|
conddescr
|
|
Detailed text description of the event. The conddescr is 1 to 64 characters of ASCII text. See condtype below.
|
condtype (ccm)
|
|
Condition type identifies the type of event (maps to cerent15216EdfaLogEventID). Possible condtype and corresponding conddescr (in quotes) are:
|
|
CTRLMODE1 (DWDM)
|
"Pump1 Control Mode Changed" (cerent15216EdfaControlMode for cerent15216EdfaPumpCfgPumpNumber=1).
|
|
CTRLMODE2 (DWDM)
|
"Pump2 Control Mode Changed" (cerent15216EdfaControlMode for cerent15216EdfaPumpCfgPumpNumber=2).
|
|
GAINCHGD (DWDM)
|
"Overall Gain Changed" (cerent15216EdfaConstGainOverallGain).
|
|
LOSHYSTCHGD (DWDM)
|
"LOS (loss of signal) Hysteresis Changed" (cerent15216EdfaLOSHysteresis).
|
|
LOSTHCHGD (DWDM)
|
"LOS (loss of signal) Threshold Changed" (cerent15216EdfaLOSThreshold).
|
|
LPOUTCHGD (DWDM)
|
"Loss of Output Power Setpoint Changed" (cerent15216EdfaLpoutSetpoint).
|
|
LPOUTDEVCHGD (DWDM)
|
"Lpout (loss of output power) Deviation Changed" (cerent15216EdfaLpoutDeviation).
|
|
LPOUTHYSTCHGD (DWDM)
|
"Lpout (loss of output power) Hysteresis Changed" (cerent15216EdfaLpoutHysteresis).
|
|
PREATTCHGD (DWDM)
|
"Pre-attenuation Changed" (cerent15216EdfaVariableGainPreAttenuation).
|
|
PWRBUSMAXCHGD (EVN)
|
"Power Bus Max (voltage) Changed" (cerent15216EdfaPowerBusDCVoltageMax).
|
|
PWRBUSMINCHGD (EVN)
|
"Power Bus Min (voltage) Changed" (cerent15216EdfaPowerBusDCVoltageMin).
|
|
PWRBUSMODE (EVN)
|
"Power Bus Mode Changed" (cerent15216EdfaPowerBusMode).
|
|
MAXCTMPCHGD (EQPT)
|
"Max Case Temperature Changed" (cerent15216EdfaCtmpMax).
|
condtype (ccm)
|
MAXCTMPHYSTCHGD (EQPT)
|
"Max Ctmp (case temperature) Hysteresis Changed" (cerent15216EdfaCtmpMaxHysteresis).
|
|
MINCTMPCHGD (EQPT)
|
"Min Case Temperature Changed" (cerent15216EdfaCtmpMin).
|
|
MINCTMPHYSTCHGD (EQPT)
|
"Min Ctmp (case temperature) Hysteresis Changed" (cerent15216EdfaCtmpMinHysteresis).
|
|
CUTOVERRESET (EQPT)
|
(Software) "Reset after Cutover" (cerent15216EdfaOpCutover).
|
|
SOFTWARELOAD (EQPT)
|
(New) "Software Load" (cerent15216EdfaOpLoad).
|
|
SOFTWARERESET (EQPT)
|
"Software Reset" (cerent15216EdfaOpReset).
|
condeff
|
string
TC
|
Effect of the condition. Always TC (transient condition).
|
date
|
yyyy-mm-dd
|
Date of origination of TL1 message.
|
ocrdat
|
m-d
|
Date (month-day) of the event occurrence (derived from cerent15216EdfaDateAndTimeString).
|
ocrtm
|
h-m-s
|
Time (hour-minute-second) of the event occurrence (derived from cerent15216EdfaDateAndTimeString).
|
sid
|
string
|
Source identifier uniquely identifies the source of a TL1 autonomous command.
|
srveff
|
|
Effect on service. Possible values are:
|
SA
|
Service affecting.
|
NSA
|
Non-service affecting.
|
time
|
hh:mm:ss
|
Time of origination of TL1 message.
|
9.7.22 REPT EVT FXFR
Command
REPT EVT FXFR
Reports autonomous events related to the FTP file transfer (see "COPY-RFILE" section). Reports when an event related to the file transfer is logged.
Syntax
<sid> <date> <time>
A <atag> REPT EVT FXFR
"<aid>:<filename>,<fxfr_status>[,<fxfr_rslt>][,<bytes_xfrd>]"
;
Example 9-24 REPT EVT FXFR Message
Amp01 2001-06-18 14:48:44
A 141 REPT EVT FXFR
"EQPT:VMRLS20.EXE,COMPLD,SUCCESS,8051"
;
Table 9-29 REPT EVT FXFR Syntax Description
Parameter
|
Syntax
|
Description
|
atag
|
0 - 999
|
An integer between 0 and 999 used as a sequence number in autonomous messages.
|
aid
|
|
Always EQPT.
|
EQPT
|
General parameters of the ONS 15216 EDFA2 (not directly affecting optical signal or power bus).
|
bytes_xfrd
|
|
Total number of bytes transferred when fxfr_status is COMPLD. See fxfr_status below.
|
filename
|
|
Identifies the name of the file that is being transferred.
|
fxfr_rslt
|
|
File transfer result indicates success or failure of the file transfer. This is displayed only when the file transfer has completed (i.e., fxfr_status is COMPLD). Possible values are:
|
SUCCESS
|
File transfer was successful.
|
FAILURE
|
File transfer failed.
|
fxfr_status
|
|
File transfer status of ONS 15216 EDFA2's file transfer at the current time. (The option IP (in progress) has not been implemented.) Possible values are:
|
START
|
File transfer has started.
|
COMPLD
|
File transfer has completed.
|
date
|
yyyy-mm-dd
|
Date of origination of TL1 message.
|
sid
|
string
|
Source identifier uniquely identifies the source of a TL1 autonomous command.
|
time
|
hh:mm:ss
|
Time of origination of TL1 message.
|
9.7.23 RTRV-ALM-ALL
Command
RTRV-ALM-ALL
Generates a report on all active alarms (except environmental (ENV) alarms as per Telcordia GR-833-CORE). Note that the ccm does not appear in the response for EQPT alarms.
Note The messages for Loss of Signal (LOS), Gain Out of Range (GAIN), and Loss of Output Power (LPOUT) are prioritized (in the order just listed) so that only one message can be delivered at one time. For example, if the ONS 15216 EDFA2 detects both a loss of input signal and a loss of output power at the same time, it will deliver only the Loss of Signal (LOS) message to the user. This prioritized filtering of alarms does not occur with the SNMP delivery of alarms of the ONS 15216 EDFA2.
Syntax
RTRV-ALM-ALL:[<tid>]::<ctag>::[<ntfcncde>],[<condtype>],[<srveff>][,,,,,];
<sid> <date> <time>
M <ctag> COMPLD
"<aid>,<ccm>:<ntfcncde>,<condtype>,<srveff>,<ocrdat>,<ocrtm>,,:<conddescr>"
;
Example 9-25 RTRV-ALM-ALL Command and Response
Amp01:ONS15216 EDFA2> RTRV-ALM-ALL:Amp01::229::MN,LCRNT1,NSA,,;
Amp01 2002-06-20 14:30:00
M 229 COMPLD
"1,DWDM:MJ,LOS,SA,6-20,14-25-30,,:\"Loss Of Signal\""
"EQPT,EQPT:MN,LCRNT1,NSA,6-20,14-25-30,,:\"Excessive Pump1 Current\""
;
Table 9-30 RTRV-ALM-ALL Syntax Description
Parameter
|
Syntax
|
Description
|
aid
|
|
Possible values are:
|
1
|
Directly affecting the optical signal
|
EQPT
|
General parameters of the ONS 15216 EDFA2 (not directly affecting optical signal or power bus)
|
conddescr
|
|
Detailed text description of the event. The conddescr is 1 to 64 characters of ASCII text. See condtype below
|
condtype (ccm)
|
|
Condition type identifies the type of alarm (maps to cerent15216EdfaLogEventID). Possible condtype and corresponding conddescr (in quotes) are:
|
LOS (DWDM)
|
"Loss of Signal" (input power) alarm (cerent15216EdfaAlarmLpin).
|
GAIN (DWDM)
|
"Gain Out of Range" alarm (cerent15216EdfaAlarmGain).
|
LPOUT (DWDM)
|
"Loss of Output Power" alarm (cerent15216EdfaAlarmLpout).
|
CTMP (EQPT)
|
"Case Temperature Out of Range" alarm (cerent15216EdfaAlarmCtmp).
|
LCRNT1 (EQPT)
|
"Excessive Pump1 Current" alarm (cerent15216EdfaAlarmLcrnt1).
|
LCRNT2 (EQPT)
|
"Excessive Pump2 Current" alarm (cerent15216EdfaAlarmLcrnt2).
|
LTMP1 (EQPT)
|
"Excessive Pump1 Temperature" alarm (cerent15216EdfaAlarmLtmp1).
|
LTMP2 (EQPT)
|
"Excessive Pump2 Temperature" alarm (cerent15216EdfaAlarmLtmp2).
|
date
|
yyyy-mm-dd
|
Date of origination of TL1 message.
|
ntfncde
|
|
Notification code (maps to cerent15216EdfaAlarmPriority). Possible values are:
|
CR
|
Critical alarm.
|
MJ
|
Major alarm.
|
MN
|
Minor alarm.
|
CL
|
Cleared alarm.
|
NA
|
No alarm.
|
ocrdat
|
m-d
|
Date (month-day) of the event occurrence (derived from cerent15216EdfaDateAndTimeString).
|
ocrtm
|
h-m-s
|
Time (hour-minute-second) of the event occurrence (derived from cerent15216EdfaDateAndTimeString).
|
sid
|
string
|
Source identifier uniquely identifies the source of a TL1 autonomous command.
|
srveff
|
|
Effect on service. Possible values are:
|
SA
|
Service affecting.
|
NSA
|
Non-service affecting.
|
time
|
hh:mm:ss
|
Time of origination of TL1 message.
|
9.7.24 RTRV-ALM-DWDM
Command
RTRV-ALM-DWDM
Generates a report on active DWDM alarms.
Note The messages for Loss of Signal (LOS), Gain Out of Range (GAIN), and Loss of Output Power (LPOUT) are prioritized (in the order just listed) so that only one message can be delivered at one time. For example, if the ONS 15216 EDFA2 detects both a loss of input signal and a loss of output power at the same time, it will deliver only the Loss of Signal (LOS) message to the user. This prioritized filtering of alarms does not occur with the SNMP delivery of alarms of the ONS 15216 EDFA2.
Syntax
RTRV-ALM-DWDM:[<tid>]:<aid>:<ctag>::[<ntfcncde>],[<condtype>],[<srveff>][,,,,,];
<sid> <date> <time>
M <ctag> COMPLD
"<aid>,<ccm>:<ntfcncde>,<condtype>,<srveff>,<ocrdat>,<ocrtm>,,:<conddescr>"
;
Example 9-26 RTRV-ALM-DWDM Command and Response
Amp01:ONS15216 EDFA2> RTRV-ALM-DWDM:Amp01:ALL:229::,,;
Amp01 2002-06-20 14:30:00
M 229 COMPLD
"1,DWDM:MJ,LOS,SA,6-20,14-25-30,,:\"Loss Of Signal\""
;
Table 9-31 RTRV-ALM-DWDM Syntax Description
Parameter
|
Syntax
|
Description
|
aid
|
|
1 and ALL have same input effect.
|
1
|
Directly affecting the optical signal.
|
ALL
|
Any or all of the preceding (command input only).
|
conddescr
|
|
Detailed text description of the event. The conddescr is 1 to 64 characters of ASCII text. See condtype below.
|
condtype
|
|
Condition type identifies the type of alarm (maps to cerent15216EdfaLogEventID). Possible condtype and corresponding conddescr (in quotes) are:
|
LOS
|
"Loss of Signal" (input power) alarm (cerent15216EdfaAlarmLpin).
|
GAIN
|
"Gain Out of Range" alarm (cerent15216EdfaAlarmGain).
|
LPOUT
|
"Loss of Output Power" alarm (cerent15216EdfaAlarmLpout).
|
date
|
yyyy-mm-dd
|
Date of origination of TL1 message.
|
ntfncde
|
|
Notification code (maps to cerent15216EdfaAlarmPriority). Possible values are:
|
CR
|
Critical alarm.
|
MJ
|
Major alarm.
|
MN
|
Minor alarm.
|
CL
|
Cleared alarm.
|
NA
|
No alarm.
|
ocrdat
|
m-d
|
Date (month-day) of the event occurrence (derived from cerent15216EdfaDateAndTimeString).
|
ocrtm
|
h-m-s
|
Time (hour-minute-second) of the event occurrence (derived from cerent15216EdfaDateAndTimeString).
|
sid
|
string
|
Source identifier uniquely identifies the source of a TL1 autonomous command.
|
srveff
|
|
Effect on service. Possible values are:
|
SA
|
Service affecting.
|
NSA
|
Non-service affecting.
|
time
|
hh:mm:ss
|
Time of origination of TL1 message.
|
9.7.25 RTRV-ALM-ENV
Command
RTRV-ALM-ENV
Generates a report on specific or all active environmental (power bus) alarms.
Syntax
RTRV-ALM-ENV:[<tid>]:<aid>:<ctag>::[<ntfcncde>],[<condtype>];
<sid> <date> <time>
M <ctag> COMPLD
"<aid>,<ccm>:<ntfcncde>,<condtype>,<ocrdat>,<ocrtm>,<conddescr>"
;
Example 9-27 RTRV-ALM-ENV Command and Response
Amp01:ONS15216 EDFA2> RTRV-ALM-ENV:Amp01:ALL:229::MN,PWRBUSA;
Amp01 2002-06-20 14:30:00
M 229 COMPLD
"PWR-A,ENV:MN,PWRBUSA,6-20,14-25-30,\"Power Bus A Alarm\""
;
Table 9-32 RTRV-ALM-ENV Syntax Description
Parameter
|
Syntax
|
Description
|
aid
|
|
Specifying PWR-A or PWR-B in input has a filter effect on the response.
|
PWR-A
|
Affecting Power Bus A (or both A and B).
|
PWR-B
|
Affecting Power Bus B.
|
ALL
|
Any or all of the preceding (command input only).
|
conddescr
|
|
Detailed text description of the event. The conddescr is 1 to 64 characters of ASCII text. See condtype below.
|
condtype
|
|
Condition type identifies the type of alarm (maps to cerent15216EdfaLogEventID). Possible condtype and corresponding conddescr (in quotes) are:
|
PWRBUSA
|
"Power Bus A (voltage) Alarm" (cerent15216EdfaAlarmPowerBusA).
|
PWRBUSB
|
"Power Bus B (voltage) Alarm" (cerent15216EdfaAlarmPowerBusB).
|
date
|
yyyy-mm-dd
|
Date of origination of TL1 message.
|
ntfncde
|
|
Notification code (maps to cerent15216EdfaAlarmPriority). Possible values are:
|
CR
|
Critical alarm.
|
MJ
|
Major alarm.
|
MN
|
Minor alarm.
|
CL
|
Cleared alarm.
|
NA
|
No alarm.
|
ocrdat
|
m-d
|
Date (month-day) of the event occurrence (derived from cerent15216EdfaDateAndTimeString).
|
ocrtm
|
h-m-s
|
Time (hour-minute-second) of the event occurrence (derived from cerent15216EdfaDateAndTimeString).
|
sid
|
string
|
Source identifier uniquely identifies the source of a TL1 autonomous command.
|
time
|
hh:mm:ss
|
Time of origination of TL1 message.
|
9.7.26 RTRV-ALM-EQPT
Command
RTRV-ALM-EQPT
Generates a report on all active alarms (except environmental alarms as per Telcordia GR-833-CORE).
Syntax
RTRV-ALM-EQPT:[<tid>]:<aid>:<ctag>::[<ntfcncde>],[<condtype>],[<srveff>][,,,,,];
<sid> <date> <time>
M <ctag> COMPLD
"<aid>:<ntfcncde>,<condtype>,<srveff>,<ocrdat>,<ocrtm>,,:<conddescr>"
;
Example 9-28 RTRV-ALM-EQPT Command and Response
Amp01:ONS15216 EDFA2> RTRV-ALM-EQPT:Amp01:ALL:229::MN,LCRNT1,NSA,,;
Amp01 2002-06-20 14:30:00
M 229 COMPLD
"EQPT:MN,LCRNT1,NSA,6-20,14-25-30,,:\"Excessive Pump1 Current\""
;
Table 9-33 RTRV-ALM-EQPT Syntax Description
Parameter
|
Syntax
|
Description
|
aid
|
|
EQPT and ALL have same input effect.
|
EQPT
|
General parameters of the ONS 15216 EDFA2 (not directly affecting optical signal or power bus).
|
ALL
|
Any or all of the preceding (command input only).
|
conddescr
|
|
Detailed text description of the event. The conddescr is 1 to 64 characters of ASCII text. See condtype below.
|
condtype
|
|
Condition type identifies the type of alarm (maps to cerent15216EdfaLogEventID). Possible condtype and corresponding conddescr (in quotes) are:
|
CTMP
|
"Case Temperature Out of Range" alarm (cerent15216EdfaAlarmCtmp).
|
LCRNT1
|
"Excessive Pump1 Current" alarm (cerent15216EdfaAlarmLcrnt1).
|
LCRNT2
|
"Excessive Pump2 Current" alarm (cerent15216EdfaAlarmLcrnt2).
|
LTMP1
|
"Excessive Pump1 Temperature" alarm (cerent15216EdfaAlarmLtmp1).
|
LTMP2
|
"Excessive Pump2 Temperature" alarm (cerent15216EdfaAlarmLtmp2).
|
date
|
yyyy-mm-dd
|
Date of origination of TL1 message.
|
ntfncde
|
|
Notification code (maps to cerent15216EdfaAlarmPriority). Possible values are:
|
CR
|
Critical alarm.
|
MJ
|
Major alarm.
|
MN
|
Minor alarm.
|
CL
|
Cleared alarm.
|
NA
|
No alarm.
|
ocrdat
|
m-d
|
Date (month-day) of the event occurrence (derived from cerent15216EdfaDateAndTimeString).
|
ocrtm
|
h-m-s
|
Time (hour-minute-second) of the event occurrence (derived from cerent15216EdfaDateAndTimeString).
|
sid
|
string
|
Source identifier uniquely identifies the source of a TL1 autonomous command.
|
srveff
|
|
Effect on service. Possible values are:
|
SA
|
Service affecting.
|
NSA
|
Non-service affecting.
|
time
|
hh:mm:ss
|
Time of origination of TL1 message.
|
9.7.27 RTRV-AO
Command
RTRV-AO
Retrieves autonomous output.
Allows the operating system to retrieve a copy of queued autonomous messages or missing autonomous messages. Examples of autonomous messages are REPT ALM and REPT EVT.
Users can retrieve up to the latest 1000 autonomous messages (alarms and events). Normally, users should limit the retrieval to less than 200 messages to prevent alarm reporting and other active users from being impacted. To retrieve more than 200 messages, it is recommended that the user saves the autonomous message log to a file using the CPY-MEM command and then get the file through FTP using the COPY-RFILE command.
If none of the stored automatic messages satisfy the selection criteria, then a complete normal response is sent. If one or more stored autonomous messages satisfy the criteria, then the messages should be reported in the normal response in ATAG order.
Syntax
RTRV-AO:[<tid>]::<ctag>:::[ATAGSEQ=<atagseq>][,MSGTYPE=<msgtype>];
Example 9-29 RTRV-AO Command
Amp01:ONS15216 EDFA2> RTRV-AO:Amp01::123:::ATAGSEQ=20&&30,MSGTYPE=EVT;
Table 9-34 RTRV-AO Syntax Description
Parameter
|
Syntax
|
Description
|
atagseq
|
|
atag is an integer between 0 and 999 used by the ONS 15216 EDFA2 to sequentially number in autonomous messages. atagseq can be a single atag number or a range of numbers in the form AA&&BB, where AA and BB are integers. If null, the 20 latest messages will be retrieved.
|
msgtype
|
|
Type of message. A null value means both ALM and EVT.
|
ALM
|
Alarm message.
|
EVT
|
Event message.
|
9.7.28 RTRV-COND-ALL
Command
RTRV-COND-ALL
Generates a report on the condition (state) of all alarms (except environmental alarms). Note that the ccm does not appear in the response for EQPT alarms.
Note The messages for Loss of Signal (LOS), Gain Out of Range (GAIN), and Loss of Output Power (LPOUT) are prioritized (in the order just listed) so that only one message can be delivered at one time. For example, if the ONS 15216 EDFA2 detects both a loss of input signal and a loss of output power at the same time, it will deliver only the Loss of Signal (LOS) message to the user. This prioritized filtering of alarms does not occur with the SNMP delivery of alarms of the ONS 15216 EDFA2.
Syntax
RTRV-COND-ALL:[<tid>]::<ctag>::[<condtype>][,,,];
<sid> <date> <time>
M <ctag> COMPLD
"<aid>,<ccm>:<ntfcncde>,<condtype>,<srveff>,<ocrdat>,<ocrtm>,,,<conddescr>"
;
Example 9-30 RTRV-COND-ALL Command and Response
Amp01:ONS15216 EDFA2> RTRV-COND-ALL:Amp01::229::LCRNT1;
Amp01 2002-06-20 14:30:00
M 229 COMPLD
"1,DWDM:MJ,LOS,SA,6-20,14-25-30,,,\"Loss Of Signal\""
"EQPT,EQPT:MN,LCRNT1,NSA,6-20,14-25-30,,,\"Excessive Pump1 Current\""
;
Table 9-35 RTRV-COND-ALL Syntax Description
Parameter
|
Syntax
|
Description
|
aid
|
|
Possible values are:
|
1
|
Directly affecting the optical signal.
|
EQPT
|
General parameters of the ONS 15216 EDFA2 (not directly affecting optical signal or power bus).
|
conddescr
|
|
Detailed text description of the event. The conddescr is 1 to 64 characters of ASCII text. See condtype below.
|
condtype (ccm)
|
|
Condition type identifies the type of alarm (maps to cerent15216EdfaLogEventID). Possible condtype and corresponding conddescr (in quotes) are:
|
LOS (DWDM)
|
"Loss of Signal" (input power) alarm (cerent15216EdfaAlarmLpin).
|
GAIN (DWDM)
|
"Gain Out of Range" alarm (cerent15216EdfaAlarmGain).
|
LPOUT (DWDM)
|
"Loss of Output Power" alarm (cerent15216EdfaAlarmLpout).
|
CTMP (EQPT)
|
"Case Temperature Out of Range" alarm (cerent15216EdfaAlarmCtmp).
|
LCRNT1 (EQPT)
|
"Excessive Pump1 Current" alarm (cerent15216EdfaAlarmLcrnt1).
|
LCRNT2 (EQPT)
|
"Excessive Pump2 Current" alarm (cerent15216EdfaAlarmLcrnt2).
|
LTMP1 (EQPT)
|
"Excessive Pump1 Temperature" alarm (cerent15216EdfaAlarmLtmp1).
|
LTMP2 (EQPT)
|
"Excessive Pump2 Temperature" alarm (cerent15216EdfaAlarmLtmp2).
|
date
|
yyyy-mm-dd
|
Date of origination of TL1 message.
|
ntfncde
|
|
Notification code (maps to cerent15216EdfaAlarmPriority). Possible values are:
|
CR
|
Critical alarm.
|
MJ
|
Major alarm.
|
MN
|
Minor alarm.
|
NA
|
No alarm.
|
ocrdat
|
m-d
|
Date (month-day) of the event occurrence (derived from cerent15216EdfaDateAndTimeString).
|
ocrtm
|
h-m-s
|
Time (hour-minute-second) of the event occurrence (derived from cerent15216EdfaDateAndTimeString).
|
sid
|
string
|
Source identifier uniquely identifies the source of a TL1 autonomous command.
|
srveff
|
|
Effect on service. Possible values are:
|
SA
|
Service affecting.
|
NSA
|
Non-service affecting.
|
time
|
hh:mm:ss
|
Time of origination of TL1 message.
|
9.7.29 RTRV-COND-DWDM
Command
RTRV-COND-DWDM
Generates a report on the condition (state) of DWDM alarms.
Note The messages for Loss of Signal (LOS), Gain Out of Range (GAIN), and Loss of Output Power (LPOUT) are prioritized (in the order just listed) so that only one message can be delivered at one time. For example, if the ONS 15216 EDFA2 detects both a loss of input signal and a loss of output power at the same time, it will deliver only the Loss of Signal (LOS) message to the user. This prioritized filtering of alarms does not occur with the SNMP delivery of alarms of the ONS 15216 EDFA2.
Syntax
RTRV-COND-DWDM:[<tid>]:<aid>:<ctag>::[<condtype>][,,,];
<sid> <date> <time>
M <ctag> COMPLD
"<aid>,<ccm>:<ntfcncde>,<condtype>,<srveff>,<ocrdat>,<ocrtm>,,,<conddescr>"
;
Example 9-31 RTRV-COND-DWDM Command and Response
Amp01:ONS15216 EDFA2> RTRV-COND-DWDM:Amp01:ALL:229::LOS;
Amp01 2002-06-20 14:30:00
M 229 COMPLD
"1,DWDM:MJ,LOS,SA,6-20,14-25-30,,,\"Loss Of Signal\""
;
Table 9-36 RTRV-COND-DWDM Syntax Description
Parameter
|
Syntax
|
Description
|
aid
|
|
1 and ALL have same input effect.
|
1
|
Directly affecting the optical signal.
|
ALL
|
Any or all of the preceding (command input only).
|
conddescr
|
|
Detailed text description of the event. The conddescr is 1 to 64 characters of ASCII text. See condtype below.
|
condtype
|
|
Condition type identifies the type of alarm (maps to cerent15216EdfaLogEventID). Possible condtype and corresponding conddescr (in quotes) are:
|
LOS
|
"Loss of Signal" (input power) alarm (cerent15216EdfaAlarmLpin).
|
GAIN
|
"Gain Out of Range" alarm (cerent15216EdfaAlarmGain).
|
LPOUT
|
"Loss of Output Power" alarm (cerent15216EdfaAlarmLpout).
|
date
|
yyyy-mm-dd
|
Date of origination of TL1 message.
|
ntfncde
|
|
Notification code (maps to cerent15216EdfaAlarmPriority). Possible values are:
|
CR
|
Critical alarm.
|
MJ
|
Major alarm.
|
MN
|
Minor alarm.
|
NA
|
No alarm.
|
ocrdat
|
m-d
|
Date (month-day) of the event occurrence (derived from cerent15216EdfaDateAndTimeString).
|
ocrtm
|
h-m-s
|
Time (hour-minute-second) of the event occurrence (derived from cerent15216EdfaDateAndTimeString).
|
sid
|
string
|
Source identifier uniquely identifies the source of a TL1 autonomous command.
|
srveff
|
|
Effect on service. Possible values are:
|
SA
|
Service affecting.
|
NSA
|
Non-service affecting.
|
time
|
hh:mm:ss
|
Time of origination of TL1 message.
|
9.7.30 RTRV-COND-ENV
Command
RTRV-COND-ENV
Generates a report on the condition (state) of environmental (power bus) alarms.
Syntax
RTRV-COND-ENV:[<tid>]:<aid>:<ctag>::[<condtype>][,,];
<sid> <date> <time>
M <ctag> COMPLD
"<aid>,<ccm>:<ntfcncde>,<condtype>,<srveff>,<ocrdat>,<ocrtm>,,,<conddescr>"
;
Example 9-32 RTRV-COND-ENV Command and Response
Amp01:ONS15216 EDFA2> RTRV-COND-ENV:Amp01:ALL:229::PWRBUSA;
Amp01 2002-06-20 14:30:00
M 229 COMPLD
"PWR-A,ENV:MN,PWRBUSA,NSA,6-20,14-25-30,,,\"Power Bus A Alarm\""
;
Table 9-37 RTRV-COND-ENV Syntax Description
Parameter
|
Syntax
|
Description
|
aid
|
|
Specifying PWR-A or PWR-B in input has a filter effect on the response.
|
PWR-A
|
Affecting Power Bus A (or both A and B).
|
PWR-B
|
Affecting Power Bus B.
|
ALL
|
Any or all of the preceding (command input only).
|
conddescr
|
|
Detailed text description of the event. The conddescr is 1 to 64 characters of ASCII text. See condtype below.
|
condtype
|
|
Condition type identifies the type of alarm (maps to cerent15216EdfaLogEventID). Possible condtype and corresponding conddescr (in quotes) are:
|
PWRBUSA
|
"Power Bus A (voltage) Alarm" (cerent15216EdfaAlarmPowerBusA).
|
PWRBUSB
|
"Power Bus B (voltage) Alarm" (cerent15216EdfaAlarmPowerBusB).
|
date
|
yyyy-mm-dd
|
Date of origination of TL1 message.
|
ntfncde
|
|
Notification code (maps to cerent15216EdfaAlarmPriority). Possible values are:
|
CR
|
Critical alarm.
|
MJ
|
Major alarm.
|
MN
|
Minor alarm.
|
NA
|
No alarm.
|
ocrdat
|
m-d
|
Date (month-day) of the event occurrence (derived from cerent15216EdfaDateAndTimeString).
|
ocrtm
|
h-m-s
|
Time (hour-minute-second) of the event occurrence (derived from cerent15216EdfaDateAndTimeString).
|
sid
|
string
|
Source identifier uniquely identifies the source of a TL1 autonomous command.
|
srveff
|
|
Effect on service. Possible values are:
|
SA
|
Service affecting.
|
NSA
|
Non-service affecting.
|
time
|
hh:mm:ss
|
Time of origination of TL1 message.
|
9.7.31 RTRV-COND-EQPT
Command
RTRV-COND-EQPT
Generates a report on the condition (state) of general alarms.
Syntax
RTRV-COND-EQPT:[<tid>]:<aid>:<ctag>::[<condtype>][,,,];
<sid> <date> <time>
M <ctag> COMPLD
"<aid>:<ntfcncde>,<condtype>,<srveff>,<ocrdat>,<ocrtm>,,,<conddescr>"
;
Example 9-33 RTRV-COND-EQPT Command and Response
Amp01:ONS15216 EDFA2> RTRV-COND-EQPT:Amp01:ALL:229::LCRNT1;
Amp01 2002-06-20 14:30:00
M 229 COMPLD
"EQPT:MN,LCRNT1,NSA,6-20,14-25-30,,,\"Excessive Pump1 Current\""
;
Table 9-38 RTRV-COND-EQPT Syntax Description
Parameter
|
Syntax
|
Description
|
aid
|
|
EQPT and ALL have same input effect.
|
EQPT
|
General parameters of the ONS 15216 EDFA2 (not directly affecting optical signal or power bus).
|
ALL
|
Any or all of the preceding (command input only).
|
conddescr
|
|
Detailed text description of the event. The conddescr is 1 to 64 characters of ASCII text. See condtype below.
|
condtype
|
|
Condition type identifies the type of alarm (maps to cerent15216EdfaLogEventID). Possible condtype and corresponding conddescr (in quotes) are:
|
CTMP
|
"Case Temperature Out of Range" alarm (cerent15216EdfaAlarmCtmp).
|
LCRNT1
|
"Excessive Pump1 Current" alarm (cerent15216EdfaAlarmLcrnt1).
|
LCRNT2
|
"Excessive Pump2 Current" alarm (cerent15216EdfaAlarmLcrnt2).
|
LTMP1
|
"Excessive Pump1 Temperature" alarm (cerent15216EdfaAlarmLtmp1).
|
LTMP2
|
"Excessive Pump2 Temperature" alarm (cerent15216EdfaAlarmLtmp2).
|
date
|
yyyy-mm-dd
|
Date of origination of TL1 message.
|
ntfncde
|
|
Notification code (maps to cerent15216EdfaAlarmPriority). Possible values are:
|
CR
|
Critical alarm.
|
MJ
|
Major alarm.
|
MN
|
Minor alarm.
|
NA
|
No alarm.
|
ocrdat
|
m-d
|
Date (month-day) of the event occurrence (derived from cerent15216EdfaDateAndTimeString).
|
ocrtm
|
h-m-s
|
Time (hour-minute-second) of the event occurrence (derived from cerent15216EdfaDateAndTimeString).
|
sid
|
string
|
Source identifier uniquely identifies the source of a TL1 autonomous command.
|
srveff
|
|
Effect on service. Possible values are:
|
SA
|
Service affecting.
|
NSA
|
Non-service affecting.
|
time
|
hh:mm:ss
|
Time of origination of TL1 message.
|
9.7.32 RTRV-DFLT-SECU
Command
RTRV-DFLT-SECU
Retrieves the timeout value(s) for user access level(s).
Syntax
RTRV-DFLT-SECU:[<tid>]:<aid>:<ctag>;
<sid> <date> <time>
M <ctag> COMPLD
"<aid>:AL=<al>,TMOUT=<timeout>"
;
Example 9-34 RTRV-DFLT-SECU Command and Response
Amp01:ONS15216 EDFA2> RTRV-DFLT-SECU:Amp01:ALL:123;
Amp01 2002-01-12 08:01:05
M 123 COMPLD
"EQPT:AL=R,TMOUT=60"
"EQPT:AL=RW,TMOUT=30"
"EQPT:AL=RWA,TMOUT=15"
;
Table 9-39 RTRV-DFLT-SECU Syntax Description
Parameter
|
Syntax
|
Description
|
date
|
yyyy-mm-dd
|
Date of origination of TL1 message.
|
time
|
hh:mm:ss
|
Time of origination of TL1 message.
|
aid
|
|
EQPT and ALL have same input effect.
|
EQPT
|
General parameters of the ONS 15216 EDFA2 (not directly affecting optical signal or power bus).
|
ALL
|
Any or all of the preceding (command input only).
|
al
|
|
Access level of the user. See "Summary of Security Permissions for TL1 Commands" section for access level permissions.
|
R
|
Read only privileges.
|
RW
|
Read and write privileges.
|
RWA
|
Read, write, and administrative privileges.
|
timeout
|
integer
|
Timeout in minutes.
|
9.7.33 RTRV-DWDM
Command
RTRV-DWDM
Retrieves the ONS 15216 EDFA2 optical control configuration.
Syntax
RTRV-DWDM:[<tid>]:<aid>:<ctag>;
<sid> <date> <time>
M <ctag> COMPLD
"<aid>:INPWRMICROW=<inputpoweruw>,INPWRDBM=<inputpowerdbm>,OUTPWRMILLIW=<outputpowermw>
,OUTPWRDBM=<outputpowerdbm>,PUMP1CTRLMODE=<pump1ctrlmode>,PUMP1CTRLVALUE=<pump1ctrlvalue>,
PUMP2CTRLMODE=<pump2ctrlmode>,PUMP2CTRLVALUE=<pump2ctrlvalue>,OVERALLGAINMEASURED=<gainmea
sured>,CONFIGGAIN=<gain>,PREATTMEASURED=<preattmeasured>"
;
Example 9-35 RTRV-DWDM Command and Response
Amp01:ONS15216 EDFA2> RTRV-DWDM:Amp01:ALL:123;
Amp01 2002-06-20 14:30:00
M 124 COMPLD
"1:INPWRMICROW=264,INPWRDBM=-1578,OUTPWRMILLIW=172,OUTPWRDBM=237,PUMP1CTRLMODE=GAINTEMP
,PUMP1CTRLVALUE=169,PUMP2CTRLMODE=GAINTEMP,PUMP2CTRLVALUE=169,OVERALLGAINMEASURED=169,CONF
IGGAIN=170,PREATTMEASURED=60"
;
Table 9-40 RTRV-DWDM Syntax Description
Parameter
|
Syntax
|
Description
|
date
|
yyyy-mm-dd
|
Date of origination of TL1 message.
|
time
|
hh:mm:ss
|
Time of origination of TL1 message.
|
aid
|
|
1 and ALL have same input effect.
|
1
|
Directly affecting the optical signal.
|
ALL
|
Any or all of the preceding (command input only).
|
inputpoweruw
|
0 - 99999
|
Input power (signal) in units of 10 microW (cerent15216EdfaInPoweruW).
|
inputpowerdbm
|
-999999 - 999999
|
Input power (signal) in units of 100 dBm (cerent15216EdfaInPowerdBm).
|
outputpowermw
|
0 - 999999
|
Output power in units of 100 mW (cerent15216EdfaOutPowermW).
|
outputpowerdbm
|
-99999 - 99999
|
Output power in units of 100 dBm (cerent15216EdfaOutPowerdBm).
|
pump1ctrlmode, pump2ctrlmode
|
|
Pump 1 or pump 2 control mode (maps to cerent15216EdfaPumpCfgControlMode for the corresponding pump). Possible values are:
|
GAINTEMP
|
Constant Gain Temperature Compensated mode (manufacturer default) (cerent15216EdfaPumpCfgControlMode set to constGainTempComp).
|
OPWR
|
Constant Output Power mode (cerent15216EdfaPumpCfgControlMode set to constOutputPower). A valid mode only for pump 2.
|
CRNT
|
Constant Pump Current mode (cerent15216EdfaPumpCfgControlMode set to constCurrent).
|
PWR
|
Constant Pump Power mode (cerent15216EdfaPumpCfgControlMode set to constPower).
|
IDLE
|
Pump is shut down (cerent15216EdfaPumpCfgControlMode set to idle).
|
pump1ctrlvalue, pump2ctrlvalue
|
|
Pump 1 or pump 2 control value. This value's interpretation depends on the control mode of the corresponding pump. Possible values are:
|
0 - 650
|
Output power in units of 10 mW when mode is OPWR (gets cerent15216EdfaPumpCfgConstOutPower).
|
0 - 300
|
Current value in mA when mode is CRNT (gets cerent15216EdfaPumpCfgConstPumpCurrent).
|
0 - 100
|
Pump power in mW when mode is PWR (gets cerent15216EdfaPumpCfgConstPumpPower).
|
gainmeasured
|
0 - 230
|
Value of gain in units of 10 dB when mode is GAINTEMP (gets cerent15216EdfaConstGainOverallGainMeasured).
|
gain
|
130 - 220
|
Value of gain setpoint in units of 10 dB when mode is GAINTEMP (gets cerent15216EdfaConstGainOverallGainMeasured). Same as OVERALLGAIN.
|
preattmeasured
|
0 - 110
|
Gain pre-attenuation value in units of 10 dB (gets cerent15216EdfaVariableGainPreAttenuationMeasured).
|
9.7.34 RTRV-ENV
Command
RTRV-ENV
Retrieves the ONS 15216 EDFA2 environmental parameter configuration.
Syntax
RTRV-ENV:[<tid>]:<aid>:<ctag>;
<sid> <date> <time>
M <ctag> COMPLD
"<aid>:PWRBUSMODE=<pwrbusmode>"
;
Example 9-36 RTRV-ENV Command and Response
Amp01:ONS15216 EDFA2> RTRV-ENV:Amp01:ALL:123;
Amp01 2002-06-20 14:30:00
M 123 COMPLD
"PWR-B:PWRBUSMODE=DUPLEX"
;
Table 9-41 RTRV-ENV Syntax Description
Parameter
|
Syntax
|
Description
|
date
|
yyyy-mm-dd
|
Date of origination of TL1 message.
|
time
|
hh:mm:ss
|
Time of origination of TL1 message.
|
aid
|
|
PWR-A, PWR-B, and ALL have same input effect.
|
PWR-A
|
Affecting Power Bus A (or both A and B).
|
PWR-B
|
Affecting Power Bus B.
|
ALL
|
Any or all of the preceding (command input only).
|
pwrbusmode
|
|
Power bus mode setting (cerent15216EdfaPowerBusMode). Possible values are:
|
SIMPLEX
|
Simplex mode. Requires power only to bus A (cerent15216EdfaPowerBusMode set to simplex).
|
DUPLEX
|
Duplex mode (manufacturer default). Requires power to both bus A and bus B (cerent15216EdfaPowerBusMode set to duplex).
|
9.7.35 RTRV-HDR
Command
RTRV-HDR
Retrieves header. Sends standard keep-alive message used to ping the ONS 15216 EDFA2. It also returns the current date, time, and sid/tid name of the ONS 15216 EDFA2 in the reply.
Syntax
RTRV-HDR:[<tid>]::<ctag>;
<sid> <date> <time>
M <ctag> COMPLD
;
Example 9-37 RTRV-HDR Command and Response
Amp01:ONS15216 EDFA2> RTRV-HDR:Amp01::100;
Amp01 2001-06-08 08:10:50
M 100 COMPLD
;
Table 9-42 RTRV-HDR Syntax Description
Parameter
|
Syntax
|
Description
|
date
|
yyyy-mm-dd
|
Date of origination of TL1 message.
|
time
|
hh:mm:ss
|
Time of origination of TL1 message.
|
9.7.36 RTRV-INV
Command
RTRV-INV
Retrieves the inventory information of the ONS 15216 EDFA2.
Syntax
RTRV-INV:[<tid>]:<aid>:<ctag>;
<sid> <date> <time>
M <ctag> COMPLD
"<aid>:CLEI=<cleicode>,DESCR=<descr>,NAME=<name>,HARDWAREREV=<hwrev>,
FIRMWAREREV=<fwrev>,SOFTWAREREV=<swrev>,SERIALNUM=<serialnum>,MFGNAME=<mfg>,MODELNAME=<mod
el>"
;
Example 9-38 RTRV-INV Command and Response
Amp01:ONS15216 EDFA2> RTRV-INV:Amp01:ALL:123;
Amp01 2002-01-12 08:01:05
M 123 COMPLD
"EQPT:CLEI=IPI01AA0AAA,DESCR=ONS15216EDFA2,NAME=Amp01,HARDWAREREV=v3.0.0,
FIRMWAREREV=v2.3.14,SOFTWAREREV=v2.3.0,SERIALNUM=DIT0533000P,MFGNAME=Cisco
Systems,MODELNAME=511112"
;
Table 9-43 RTRV-INV Syntax Description
Parameter
|
Syntax
|
Description
|
date
|
yyyy-mm-dd
|
Date of origination of TL1 message.
|
time
|
hh:mm:ss
|
Time of origination of TL1 message.
|
aid
|
|
EQPT and ALL have same input effect.
|
EQPT
|
General parameters of the ONS 15216 EDFA2 (not directly affecting optical signal or power bus).
|
ALL
|
Any or all of the preceding (command input only).
|
cleicode
|
string
|
CLEI code (cerent15216EdfaCLEI).
|
descr
|
string
|
System description (cerent15216EdfaPhysicalDescr).
|
fwrev
|
string
|
Firmware revision number (cerent15216EdfaPhysicalFirmwareRev).
|
hwrev
|
string
|
Hardware revision number (cerent15216EdfaPhysicalHardwareRev).
|
mfg
|
string
|
Manufacturer name (cerent15216EdfaPhysicalMfgName).
|
model
|
string
|
Model name (cerent15216EdfaPhysicalModelName).
|
name
|
string
|
System's sid/tid name (sysName).
|
serialnum
|
string
|
System serial number (cerent15216EdfaPhysicalSerialNum).
|
swrev
|
string
|
Software revision number (cerent15216EdfaPhysicalSoftwareRev).
|
9.7.37 RTRV-NE-GEN
Command
RTRV-NE-GEN
Retrieves general parameters of the ONS 15216 EDFA2. Retrieves sid/tid name, IP address and mask, and default router information. Also retrieves the boot table content.
Syntax
RTRV-NE-GEN:[<tid>]::<ctag>;
<sid> <date> <time>
M <ctag> COMPLD
"<aid>:NAME=<name>,IPADDR=<ipaddr>,IPMASK=<ipmask>,DEFRTR=<defrtr>,
BOOTRECORDTYPE1=<bootrectype1>, BOOTFILENAME1=<bootfilename1>,BOOTIPADDR1=<bootipaddr1>,
BOOTRECORDTYPE2=<bootrectype2>,BOOTFILENAME2=<bootfilename2>,
BOOTIPADDR2=<bootipaddr2>,CLI=<cli>"
;
Example 9-39 RTRV-NE-GEN Command and Response
Amp01:ONS15216 EDFA2> RTRV-NE-GEN:Amp01::123;
Amp01 2002-01-12 08:01:05
M 123 COMPLD
"EQPT:NAME=Amp01,IPADDR=172.22.87.100,IPMASK=255.255.255.0,DEFRTR=172.22
.87.2,BOOTRECORDTYPE1=FLASH,BOOTFILENAME1=15216EdfaSw_2.3.0,BOOTIPADDR1=0.0.0.0,
BOOTRECORDTYPE2=TFTP,BOOTFILENAME2=bin/15216EdfaSw_2.0.1,BOOTIPADDR2=1
72.22.128.249,CLI=TL1"
;
Table 9-44 RTRV-NE-GEN Syntax Description
Parameter
|
Syntax
|
Description
|
aid
|
|
Always EQPT.
|
EQPT
|
General parameters of the ONS 15216 EDFA2 (not directly affecting optical signal or power bus).
|
name
|
string
|
System's sid/tid name (sysName).
|
ipaddr
|
string
|
IP address of the system (cerent15216EdfaSromIpMgmtEnetAddress).
|
ipmask
|
string
|
Subnet mask of the system (cerent15216EdfaSromIpMgmtEnetSubNetMask).
|
defrtr
|
string
|
IP address of the default router (cerent15216EdfaSromIpMgmtDefaultRouterAddress).
|
bootrectype1
|
|
Boot record type (cerent15216EdfaBootType for first entry). Possible values are:
|
FLASH
|
Boot from flash.
|
TFTP
|
Boot through TFTP.
|
bootfilename1
|
string
|
Boot file name (cerent15216EdfaBootFileName for first entry). File names are case sensitive.
|
bootipaddr1
|
string
|
IP address to boot from if bootrectype1 is set to TFTP (cerent15216EdfaBootIpAddress for first entry).
|
bootrectype2
|
|
Boot record type (cerent15216EdfaBootType for second entry). Possible values are:
|
FLASH
|
Boot from flash.
|
TFTP
|
Boot through TFTP.
|
bootfilename2
|
string
|
Boot file name (cerent15216EdfaBootFileName for second entry). File names are case sensitive.
|
bootipaddr2
|
string
|
IP address to boot from if bootrectype2 is set to TFTP (cerent15216EdfaBootIpAddress for second entry).
|
cli
|
|
Default type of command line interface for all EIA/TIA-232 and default telnet port user sessions with the ONS 15216 EDFA2. Possible values are:
|
TL1
|
TL1shell interface (manufacturer default).
|
ASH
|
ASH shell interface - ONS 15216 EDFA2's native interface.
|
9.7.38 RTRV-RFILE
Command
RTRV-RFILE
Lists a specific file or all files on the flash file system of the ONS 15216 EDFA2.
Syntax
RTRV-RFILE:[<tid>]::<ctag>::[<localfilename>+];
<sid> <date> <time>
M <ctag> COMPLD
"<aid>:<localfilename>"
;
Example 9-40 RTRV-RFILE Command and Response (List all Files)
Amp01:ONS15216 EDFA2> RTRV-RFILE:Amp01::123;
Amp01 2002-01-12 08:01:05
M 123 COMPLD
"EQPT:snmp.cfg,15216EdfaSw_2.3.0,passwd"
;
Example 9-41 RTRV-RFILE Command and Response (List a Specific File)
Amp01:ONS15216 EDFA2> RTRV-RFILE:Amp01::123::snmp.cfg;
Amp01 2002-01-12 08:01:05
M 123 COMPLD
"EQPT:snmp.cfg"
;
Table 9-45 RTRV-RFILE Syntax Description
Parameter
|
Syntax
|
Description
|
aid
|
|
Always EQPT.
|
EQPT
|
General parameters of the ONS 15216 EDFA2 (not directly affecting optical signal or power bus).
|
localfilename
|
string
|
Name of the file on the flash file system of the ONS 15216 EDFA2 that is to be listed. A null value in the request means all files are to be listed. A null value in the response means the file specified does not exist. File names are case sensitive.
|
9.7.39 RTRV-TH-DWDM
Command
RTRV-TH-DWDM
Retrieves optical threshold and set point values for the ONS 15216 EDFA2.
Syntax
RTRV-TH-DWDM:[<tid>]:<aid>:<ctag>::[<thresholdtype>][,][,];
<sid> <date> <time>
M <ctag> COMPLD
"<aid>,DWDM:<thresholdtype>,,,<thresholdvalue>"
;
Example 9-42 RTRV-TH-DWDM Command and Response
Amp01:ONS15216 EDFA2> RTRV-TH-DWDM:Amp01:ALL:123::LPOUTDEV;
Amp01 2001-06-08 09:00:05
M 123 COMPLD
"1,DWDM:LPOUTDEV,,,1000"
;
Table 9-46 RTRV-TH-DWDM Syntax Description
Parameter
|
Syntax
|
Description
|
date
|
yyyy-mm-dd
|
Date of origination of TL1 message.
|
time
|
hh:mm:ss
|
Time of origination of TL1 message.
|
aid
|
|
1 and ALL have same input effect.
|
1
|
Directly affecting the optical signal.
|
ALL
|
Any or all of the preceding (command input only).
|
threshholdtype and thresholdvalue pairs
|
|
Type of threshold or set point that is to be retrieved. A null value is equivalent to ALL. Possible to specify values for one or more of the following:
|
LOSHYST
|
Loss of signal (input power) hysteresis (cerent15216EdfaLOSHysteresis).
thresholdvalue can be between 0 and 1000, with default of 100, in units of 100 dB.
|
LOSTH
|
Loss of signal (input power) threshold (cerent15216EdfaLOSThreshold).
thresholdvalue can be between -3100 and -1500, with default of -3000, in units of 100 dBm.
|
LPOUTDEV
|
Loss of output power deviation (cerent15216EdfaLpoutDeviation).
thresholdvalue can be between 0 and 1000, with default of 200, in units of 100 dB.
|
LPOUTHYST
|
Loss of output power hysteresis (cerent15216EdfaLpoutHysteresis).
thresholdvalue can be between 0 and 1000, with default of 100, in units of 100 dB.
|
LPOUTSETPT
|
Loss of output power set point (cerent15216EdfaLpoutSetpoint). This read-only value is only valid when amplifier is in Constant Output Power (OPWR) and Constant Pump Power (PWR) modes. Can be disregarded when in Constant Gain Temperature Compensated (GAINTEMP) or Constant Pump Current (CRNT) mode.
thresholdvalue is read-only and automatically determined by the pump control mode with a possible value between 0 and 1000 in units of 10 mW.
|
9.7.40 RTRV-TH-ENV
Command
RTRV-TH-ENV
Retrieves threshold values of the environmental (power bus) parameters of the ONS 15216 EDFA2.
Syntax
RTRV-TH-ENV:[<tid>]:<aid>:<ctag>::[<thresholdtype>][,];
<sid> <date> <time>
M <ctag> COMPLD
"<aid>,ENV:<thresholdtype>,,,<thresholdvalue>"
;
Example 9-43 RTRV-TH-ENV Command and Response
Amp01:ONS15216 EDFA2> RTRV-TH-ENV:Amp01:ALL:123::PWRBUSMIN;
Amp01 2002-07-16 14:24:29
M 123 COMPLD
"PWR-A,ENV:PWRBUSMIN,,,420"
;
Table 9-47 RTRV-TH-ENV Syntax Description
Parameter
|
Syntax
|
Description
|
date
|
yyyy-mm-dd
|
Date of origination of TL1 message.
|
time
|
hh:mm:ss
|
Time of origination of TL1 message.
|
aid
|
|
PWR-A, PWR-B, and ALL have same input effect.
|
PWR-A
|
Affecting Power Bus A (or both A and B).
|
PWR-B
|
Affecting Power Bus B.
|
ALL
|
Any or all of the preceding (command input only).
|
threshholdtype and thresholdvalue pairs
|
|
Type of threshold that is to be retrieved. A null value is equivalent to ALL. Possible to specify values for one or more of the following:
|
PWRBUSMIN
|
Power bus minimum voltage (cerent15216EdfaPowerBusDCVoltageMin).
thresholdvalue can be between 350 and 700, with default of 400, in units of -10 VDC.
|
PWRBUSMAX
|
Power bus maximum voltage (cerent15216EdfaPowerBusDCVoltageMax).
thresholdvalue can be between 350 and 700, with default of 570, in units of -10 VDC.
|
9.7.41 RTRV-TH-EQPT
Command
RTRV-TH-EQPT
Retrieves general threshold values for the ONS 15216 EDFA2.
Syntax
RTRV-TH-EQPT:[<tid>]:<aid>:<ctag>::[<thresholdtype>][,][,];
<sid> <date> <time>
M <ctag> COMPLD
"<aid>:<thresholdtype>,,,<thresholdvalue>"
;
Example 9-44 RTRV-TH-EQPT Command and Response
Amp01:ONS15216 EDFA2> RTRV-TH-EQPT:Amp01:ALL:123::MAXCTMP;
Amp01 2001-06-08 09:00:05
M 123 COMPLD
"EQPT:MAXCTMP,,,60"
;
Table 9-48 RTRV-TH-EQPT Syntax Description
Parameter
|
Syntax
|
Description
|
date
|
yyyy-mm-dd
|
Date of origination of TL1 message.
|
time
|
hh:mm:ss
|
Time of origination of TL1 message.
|
aid
|
|
EQPT and ALL have same input effect.
|
EQPT
|
General parameters of the ONS 15216 EDFA2 (not directly affecting optical signal or power bus).
|
ALL
|
Any or all of the preceding (command input only).
|
threshholdtype and thresholdvalue pairs
|
|
Type of threshold or set point that is to be retrieved. A null value is equivalent to ALL. Possible to specify values for one or more of the following:
|
MAXCTMP
|
Maximum case temperature (cerent15216EdfaCtmpMax).
thresholdvalue can be between 20 and 70, with default of 65 in units of °C.
|
MAXCTMPHYST
|
Maximum case temperature hysteresis (cerent15216EdfaCtmpMaxHysteresis).
thresholdvalue can be between 0 and 10, with default of 1, in units of °C.
|
MINCTMP
|
Minimum case temperature (cerent15216EdfaCtmpMin).
thresholdvalue can be between -10 and 10, with default of -5, in units of °C.
|
MINCTMPHYST
|
Minimum case temperature hysteresis (cerent15216EdfaCtmpMinHysteresis).
thresholdvalue can be between 0 and 10, with default of 1, in units of °C.
|
9.7.42 RTRV-TOD
Command
RTRV-TOD
Retrieves the date and time of the ONS 15216 EDFA2.
Syntax
RTRV-TOD:[<tid>]::<ctag>[::];
<sid> <date> <time>
M <ctag> COMPLD
"<tmody>,<tmtype>,<tmsrcdv>,<tmsrcst>"
;
Example 9-45 RTRV-TOD Command and Response
Amp01:ONS15216 EDFA2> RTRV-TOD:Amp01::123;
Amp01 2002-06-20 14:30:00
M 123 COMPLD
"2002,06,20,14,30,00,000,UTC,GPS,IS-ACT"
;
Table 9-49 RTRV-TOD Syntax Description
Parameter
|
Syntax
|
Description
|
date
|
yyyy-mm-dd
|
Date of origination of TL1 message.
|
time
|
hh:mm:ss
|
Time of origination of TL1 message.
|
tmody
format:
YYYY MM DD HH MM SS sss
|
01 - 12 01 - 31 00 - 23 00 - 59 00 - 59 000
|
Time of day of the format: YYYY,MM,DD,HH,MM,SS,sss
Current calendar year Month Day Hour Minutes Seconds Sub-seconds, currently fixed at 000.
|
tmtype
|
UTC
|
Type of time, currently fixed at universal coordinated time (UTC), which is the same as Greenwich Mean Time (GMT).
|
tmsrcdv
|
GPS
|
Time source deviation, currently fixed at GPS.
|
tmsrcst
|
IS-ACT
|
State of the time source, of the format <primaryState>-<secondaryState> (per Telcordia GR-1093-CORE), currently fixed at IS-ACT (In_Service, Active).
|
9.7.43 RTRV-USER-SECU
Command
RTRV-USER-SECU
Retrieves the access level of an existing user from the system. Does not return the password.
Syntax
RTRV-USER-SECU:[<tid>]:<uid>:<ctag>;
<sid> <date> <time>
M <ctag> COMPLD
"<uid>,<al>"
;
Example 9-46 RTRV-USER-SECU Command and Response
Amp01:ONS15216 EDFA2> RTRV-USER-SECU:Amp01:jsmith:123;
Amp01 2002-05-13 17:23:16
M 123 COMPLD
"jsmith,RW"
;
Table 9-50 RTRV-USER-SECU Syntax Description
Parameter
|
Syntax
|
Description
|
sid
|
string
|
Source identifier uniquely identifies the source of a TL1 autonomous command.
|
al
|
|
Access level of the user. See "Summary of Security Permissions for TL1 Commands" section for access level permissions.
|
R
|
Read only privileges.
|
RW
|
Read and write privileges.
|
RWA
|
Read, write, and administrative privileges.
|
uid
|
string
|
User identifier (user name) of the existing user. If no user identifier is specified and the current user has RWA access level, it will list all existing users and their security levels.
|
9.7.44 SET-ATTR-SECUDFLT
Command
SET-ATTR-SECUDFLT
Sets the timeout value of user sessions for users with a specific access level. If no communication occurs for this time, the user session is closed by the ONS 15216 EDFA2 TL1 agent. Users affected by changes to the timeout must log out and log in again for the change to take effect.
Syntax
SET-ATTR-SECUDFLT:[<tid>]::<ctag>::AL=<al>,TMOUT=<timeout>[,][,][,][,][,];
Example 9-47 SET-ATTR-SECUDFLT Command
Amp01:ONS15216 EDFA2> SET-ATTR-SECUDFLT:Amp01::123::AL=RW,TMOUT=45;
Table 9-51 SET-ATTR-SECUDFLT Syntax Description
Parameter
|
Syntax
|
Description
|
al
|
|
Access level for which the timeout is being set. See "Summary of Security Permissions for TL1 Commands" section for access level permissions.
|
R
|
Read only privileges.
|
RW
|
Read and write privileges.
|
RWA
|
Read, write, and administrative privileges.
|
timeout
|
0 - 99
|
Value of the timeout in minutes for the corresponding access level. Defaults are:
R = 60 min. RW = 30 min. RWA = 15 min.
0 means no timeout.
|
9.7.45 SET-TH-DWDM
Command
SET-TH-DWDM
Sets optical threshold values for the ONS 15216 EDFA2.
Syntax
SET-TH-DWDM:[<tid>]:<aid>:<ctag>::<thresholdtype>,<thresholdvalue>[,,];
Example 9-48 SET-TH-DWDM Command
Amp01:ONS15216 EDFA2> SET-TH-DWDM:Amp01:ALL:123::LOSTH,-1500;
Table 9-52 SET-TH-DWDM Syntax Description
Parameter
|
Syntax
|
Description
|
aid
|
|
1 and ALL have same input effect.
|
1
|
Directly affecting the optical signal.
|
ALL
|
Any or all of the preceding (command input only).
|
threshholdtype and thresholdvalue pairs
|
string
|
Type of threshold that is to be set. The threshold is set to the thresholdvalue that follows the comma. Possible to specify values for one or more of the following:
|
LOSHYST
|
Loss of signal (input power) hysteresis (cerent15216EdfaLOSHysteresis).
thresholdvalue can be between 0 and 1000, with default of 100, in units of 100 dB.
|
LOSTH
|
Loss of signal (input power) threshold (cerent15216EdfaLOSThreshold).
thresholdvalue can be between -3100 and -1500, with default of -3000, in units of 100 dBm.
|
LPOUTDEV
|
Loss of output power deviation (cerent15216EdfaLpoutDeviation).
thresholdvalue can be between 0 and 1000, with default of 200, in units of 100 dB.
|
LPOUTHYST
|
Loss of output power hysteresis (cerent15216EdfaLpoutHysteresis).
thresholdvalue can be between 0 and 1000, with default of 100, in units of 100 dB.
|
9.7.46 SET-TH-ENV
Command
SET-TH-ENV
Sets threshold values of the environmental (power bus) parameters of the ONS 15216 EDFA2.
Syntax
SET-TH-ENV:[<tid>]:<aid>:<ctag>::<thresholdtype>,<thresholdvalue>[,,];
Example 9-49 SET-TH-ENV Command
Amp01:ONS15216 EDFA2> SET-TH-ENV:Amp01:PWR-A:100::PWRBUSMIN,450;
Table 9-53 SET-TH-ENV Syntax Description
Parameter
|
Syntax
|
Description
|
aid
|
|
PWR-A, PWR-B, and ALL have same input effect.
|
PWR-A
|
Sets Power Bus A and Power Bus B.
|
PWR-B
|
Sets Power Bus A and Power Bus B.
|
ALL
|
Any or all of the preceding (command input only).
|
threshholdtype and thresholdvalue pairs
|
|
Type of threshold that is to be set. The threshold is set to the thresholdvalue that follows the comma. Possible to specify values for one or more of the following:
|
PWRBUSMIN
|
Power bus minimum voltage (cerent15216EdfaPowerBusDCVoltageMin).
thresholdvalue can be between 350 and 700, with default of 400, in units of -10 VDC.
The power bus threshold has a 1.0V tolerance and a 1.0V hysteresis. If the minimum threshold is configured at 400 (-40 VDC), the alarm will not raise until the voltage goes below -39 VDC and will not clear until the voltage goes above -41VDC.
|
PWRBUSMAX
|
Power bus maximum voltage (cerent15216EdfaPowerBusDCVoltageMax).
thresholdvalue can be between 350 and 700, with default of 570, in units of -10 VDC.
The power bus threshold has a 1.0V tolerance and a 1.0V hysteresis. If the maximum threshold is configured at 570 (-57 VDC), the alarm will not raise until the voltage goes above -58 VDC and will not clear until the voltage goes below -56 VDC.
|
9.7.47 SET-TH-EQPT
Command
SET-TH-EQPT
Sets general threshold values for the ONS 15216 EDFA2.
Syntax
SET-TH-EQPT:[<tid>]:<aid>:<ctag>::<thresholdtype>,<thresholdvalue>[,,];
Example 9-50 SET-TH-EQPT Command
Amp01:ONS15216 EDFA2> SET-TH-EQPT:Amp01:ALL:123::MAXCTMP,60;
Table 9-54 SET-TH-EQPT Syntax Description
Parameter
|
Syntax
|
Description
|
aid
|
|
EQPT and ALL have same input effect.
|
EQPT
|
General parameters of the ONS 15216 EDFA2 (not directly affecting optical signal or power bus).
|
ALL
|
Any or all of the preceding (command input only).
|
threshholdtype and thresholdvalue pairs
|
string
|
Type of threshold that is to be set. The threshold is set to the thresholdvalue that follows the comma. Possible to specify values for one or more of the following:
|
MAXCTMP
|
Maximum case temperature (cerent15216EdfaCtmpMax).
thresholdvalue can be between 20 and 70, with default of 65 in units of °C.
|
MAXCTMPHYST
|
Maximum case temperature hysteresis (cerent15216EdfaCtmpMaxHysteresis).
thresholdvalue can be between 0 and 10, with default of 1, in units of °C.
|
MINCTMP
|
Minimum case temperature (cerent15216EdfaCtmpMin).
thresholdvalue can be between -10 and 10, with default of -5, in units of °C.
|
MINCTMPHYST
|
Minimum case temperature hysteresis (cerent15216EdfaCtmpMinHysteresis).
thresholdvalue can be between 0 and 10, with default of 1, in units of °C.
|
9.7.48 STA-LOCL-RST
Command
STA-LOCL-RST
Instructs the ONS 15216 EDFA2 to restore all the manufacturing default settings. The files on the flash file system (FFS), the date and time, the sid/tid name (name), and the values of manufacturing calibration are not affected. This command must be followed by the INIT-SYS command to take effect.
Warning This command resets the IP address, deletes the user directory, reverts CISCO15 to the default password, and resets other parameters to restore the unit to its state as shipped from manufacturing.
Syntax
STA-LOCL-RST:[<tid>]::<ctag>;
Example 9-51 STA-LOCL-RST Command
Amp01:ONS15216 EDFA2> STA-LOCL-RST:Amp01::10;