This chapter discusses the provisioning procedures for the Cisco ONS 15216 EDFA2 using SNMP and a proprietary command line interface named the ASH shell. See Chapter 8, "Provisioning in the TL1 Shell" for provisioning information using TL1 commands in the TL1 shell.
The provisioning procedure for the ONS 15216 EDFA2 in the ASH shell is as follows:
1. Log In via EIA/TIA-232 Port Using HyperTerminal
3. Log In via LAN Port Using Telnet (Optional)
5. Set Power Bus Mode (Simplex or Duplex)
6. Verify Amplifier Operational Status
7. Set Gain
9. Set Password
10. Add Users
11. Save Changes
12. Log Off
13. Recover Default Password
The following sections describe these steps in detail.
4.1 Log In via EIA/TIA-232 Port Using HyperTerminal
Logging in through the EIA/TIA-232 port is required to set the ONS 15216 EDFA2 IP address before there can be access via the LAN port. (See "Log In via LAN Port Using Telnet (Optional)" section.)
Step 1 Connect to the EIA/TIA-232 port on the front panel. See "EIA/TIA-232 Connection Procedure" section on page 3-7 for line connection and HyperTerminal setup instructions.
Step 2 Open HyperTerminal. (HyperTerminal can be found in the Microsoft Windows Accessories menu.)
Step 3 If you see the login window shown in Example 4-1, skip to Step 4.
By default the ONS 15216 EDFA2 is in TL1 shell, so this step may be required to proceed in ASH shell. When in TL1 shell, the screen opens to a simple prompt (sidtidname:ONS15216 EDFA2>). To change to ASH shell, log in using the procedure in "Log In via EIA/TIA-232 Port Using HyperTerminal" section on page 8-1, and then enter the following command at the hostname prompt:
Welcome to ONS15216 EDFA2 Console (v2.1.0)
sidtidname:ONS15216 EDFA2> ED-NE-GEN:::123:::CLI=ASH;
Then enter the following command at the hostname prompt:
sidtidname:ONS15216 EDFA2> INIT-SYS::ALL:1234::1;
The ONS 15216 EDFA2 should log you off and then bring up the ASH shell login window.
Step 4 Check that the ONS 15216 EDFA2 login window appears as shown in Example 4-1.
Example 4-1 ASH Shell Login Window
-- LOGIN ---------------------------------------------------- sysname
ONS15216 EDFA2 Optical Amplifier
--------------------------------
Software Version 2.1.0
Copyright (c) 2000-2001 Cisco Systems, Inc.
Username: { }
Password: { }
[Login]
Step 5 Enter both a user name and password.
The default user name and password is CISCO15 with no password (press Enter).
Note For security reasons, it is recommended to change the password from its default value. See Set Password or Set Password, page 8-10.
Step 6 Press Enter when [Login] becomes highlighted. Example 4-2 displays the login response.
Example 4-2 ASH Shell Login Response
Welcome to ONS15216 EDFA2 Console (v2.1.0)
ash:hostname:ONS15216 EDFA2>
An EIA/TIA-232 link to the ONS 15216 EDFA2 is established. The user can now provision the ONS 15216 EDFA2.
4.2 Set IP Address
Before connecting the ONS 15216 EDFA2 to a LAN, it is mandatory to set the ONS 15216 EDFA2 IP address through a local serial communication interface using the EIA/TIA-232 port on the front of the module.
Step 1 If you do not know the ONS 15216 EDFA2's IP address, subnet mask, gateway address, or host name, contact your network administrator.
Step 2 At the command prompt, enter the snmp row set local cerent15216EdfaSromIpMgmtGroup command (displayed in Example 4-3) and press Enter.
Example 4-3 Setting IP Address, Subnet Mask, Gateway Address, and Host Name
ash:hostname:ONS15216 EDFA2> snmp row set local cerent15216EdfaSromIpMgmtGroup
cerent15216EdfaSromIpMgmtEnetAddress 0.0.0.0
cerent15216EdfaSromIpMgmtEnetSubNetMask 0.0.0.0
cerent15216EdfaSromIpMgmtDefaultRouterAddress 0.0.0.0
cerent15216EdfaSromIpMgmtHostName ""
Because row set is being used in this command, the user is prompted row by row to enter the IP address, the subnet mask, the gateway address, and the host name (community ID).
Step 3 The changes must be saved prior to terminating the session. See "Save Changes" section.
Step 4 The system must be rebooted to make the IP address active. Use the processor reset command. (See "processor reset Command" section on page 6-11.)
4.3 Log In via LAN Port Using Telnet (Optional)
Provisioning of the ONS 15216 EDFA2 can be accomplished entirely through the EIA/TIA-232 port using CLI commands. After an IP address is assigned, it may be easier to provision the ONS 15216 EDFA2 using Telnet or an SNMP manager. A Telnet client is needed for CLI commands over IP. A generic SNMP manager is required for SNMP management over IP. After connecting the ONS 15216 EDFA2 to the network through its RJ-45 LAN port (see "LAN Interface (Ethernet)" section on page 3-14), the user can configure the module to accept SNMP and CLI commands via Telnet using the following procedure:
Step 1 Connect to the LAN port on the front panel. See "LAN Connection Procedure" section on page 3-14.
Step 2 Click the Microsoft Windows Start menu and select Run.
Step 3 In the text field, type the following:
telnet <ONS 15216 EDFA2 IP address> 8023
Specifying port 8023 ensures login through the ASH shell. If no port is specified, the ONS 15216 EDFA2 responds in the shell that the ONS 15216 EDFA2 is set to. (TL1 is the default shell.)
Step 4 Log in again using Step 4 through Step 6 in "Log In via EIA/TIA-232 Port Using HyperTerminal" section.
You are now connected to the ONS 15216 EDFA2 via Telnet.
4.4 Set Date and Time
Use the snmp attribute set local cerent15216EdfaRtcDateAndTimeLocalString command to set the date, time, and time zone. Entries must follow this format: "yyyy-m-d,h:m:s.s +h:m". Following the space, the time zone is set as +/- hours from Greenwich Mean Time (GMT) (also designated as universal coordinated time (UTC)) followed by a colon and minutes ahead for daylight savings. For example, Pacific Daylight Time would be -8:60 and Greenwich Mean Time would be +0:0. See Example 4-4.
Example 4-4 Setting the Date and Time
ash:hostname:ONS15216 EDFA2> snmp attribute set local cerent15216EdfaRtcDateAndTimeLocalString "2002-6-30,14:8:30.0 -8:60"
4.5 Set Power Bus Mode (Simplex or Duplex)
The ONS 15216 EDFA2 allows users to set a simplex (one power source-Bus A) or duplex (redundant power source-Bus A and Bus B) Power Bus mode. Use the snmp attribute set local cerent15216EdfaPowerBusMode command to set the desired Power Bus mode. The default mode is duplex. See Example 4-5.
Example 4-5 Setting the Power Bus Mode
ash:hostname:ONS15216 EDFA2> snmp attribute set local cerent15216EdfaPowerBusMode simplex
4.6 Verify Amplifier Operational Status
To ensure that the amplifier is working correctly on the optical level, you must verify the amplifier operational status. Use the snmp table display local cerent15216EdfaOverallStatusGroup command to verify amplifier operational status. Example 4-6 displays the output of this command.
Example 4-6 Verifying the Amplifier Operations Status
ash:hostname:ONS15216 EDFA2> snmp table display local cerent15216EdfaOverallStatusGroup
CLASS CERENT-15216-EDFA-MIB.cerent15216EdfaOverallStatusGroup ::=
{
cerent15216EdfaInPoweruW = 279;
cerent15216EdfaInPowerdBm = -1555;
cerent15216EdfaOutPowermW = 476;
cerent15216EdfaOutPowerdBm = 678;
cerent15216EdfaConstGainOverallGainMeasured = 219;
cerent15216EdfaVariableGainPreAttenuationMeasured = 10;
};
The input power (signal) should be consistent with the input power measured during the optical connection procedure. See the "Optical Connection Procedure" section on page 3-3 for more information. The output power value should be 22 dB greater than the input, assuming that the default gain setting is 22 dB.
Note An input power higher than -5 dBm will return a Gain Out of Range alarm that can be cleared by correctly setting the gain value. For more information, refer to Table 2-2.
4.7 Set Gain
To ensure that the ONS 15216 EDFA2 output signal is received by the transceiver in the network element, it is important that the gain is set correctly.
The desired output power per channel is dependent on the number of channels traversed in the amplifier. The user sets the gain of the amplifier depending on the input power (signal) level, the network application, and the required receiver specifications necessary for error-free operation. Gain range is provided in Table 3-1.
To set the amplifier gain, enter the snmp attribute set local cerent15216EdfaConstGainOverallGain gainvalue command, where gainvalue is the desired gain multiplied by ten. For example, if the desired gain is 20 dB, the gainvalue would be set to 200. Example 4-7 shows the command used to set the gain.
Example 4-7 Setting the Gain
ash:hostname:ONS15216 EDFA2> snmp attribute set local cerent15216EdfaConstGainOverallGain 200
Note Prior to changing or implementing gain changes, consult with the Cisco TAC to ensure proper network operation.
4.8 Set Alarm Thresholds
Alarm thresholds are set so that the network operator can be notified when valid alarms occur via the RJ-45 ALARM OUT and RJ-45 LAN ports on the front panel of the ONS 15216 EDFA2. (See Figure 4-1.)
Figure 4-1 ONS 15216 EDFA2 Front Panel
Alarms are reported for the following conditions:
•Loss or degradation of electrical power
•Pump laser overheating, excessive pump current
•Loss or degradation of optical input
Alarms can be connected to a network operations center (NOC) network management system (NMS) via a network element miscellaneous discrete input and/or office alarm panel/system.
For a full description of alarm threshold command attributes, refer to Chapter 5, "SNMP MIB Installation and Configuration" or Chapter 6, "ASH Commands."
To display the alarm thresholds, use the snmp table display local cerent15216EdfaCfgGroup command ( Example 4-8). This command returns the current alarm threshold default values.
Example 4-8 Displaying the Alarm Thresholds
ash:hostname:ONS15216 EDFA2> snmp table display local cerent15216EdfaCfgGroup
CLASS CERENT-15216-EDFA-MIB.cerent15216EdfaCfgGroup ::=
{
cerent15216EdfaCfgSaved = false;
cerent15216EdfaLpoutSetpoint = 0;
cerent15216EdfaLpoutDeviation = 200;
cerent15216EdfaLpoutHysteresis = 100;
cerent15216EdfaLOSThreshold = -2600;
cerent15216EdfaLOSHysteresis = 100;
cerent15216EdfaCtmpMin = -5;
cerent15216EdfaCtmpMinHysteresis = 1;
cerent15216EdfaCtmpMax = 65;
cerent15216EdfaCtmpMaxHysteresis = 1;
cerent15216EdfaCLEI = "";
cerent15216EdfaPowerBusMode = duplex;
cerent15216EdfaPowerBusDCVoltageMin = 410;
cerent15216EdfaPowerBusDCVoltageMax = 560;
};
To set the alarm thresholds, use the snmp row set local cerent15216EdfaCfgGroup command. After this command is entered, the user is prompted to modify each attribute, row by row, until all attributes are set. Alarm threshold attributes are described in Table 4-1.
4.9 Set Password
To restrict access to the ONS 15216 EDFA2, use the user passwd set command to change the default user password. The password must be a string of up to 10 characters, where at least 2 are non-alphabetic characters and at least 1 is a special character. With the exception of the administrator access level (read_write_admin), users can only modify their own passwords. For additional information on user levels, refer to Table 6-1. Example 4-9 displays the command.
Example 4-9 Changing Current User's Password
ash:hostname:ONS15216 EDFA2> user passwd set
Password =
****
New Password =
******
Confirm New Password =
******
Note The default user name for the administrator level is CISCO15 with no default password. To start a session for this user name, press Enter.
4.10 Add Users
Use the user entry create command to add new users to the ONS 15216 EDFA2. The syntax is to enter the command followed by the user name and then the access level (read, read_write, read_write_admin) as shown in Example 4-10. The ONS 15216 EDFA2 responds with a request for the password.
Passwords must be an ASCII string of up to 10 characters, where at least 2 are non-alphabetic characters with at least one special character. Special characters are +, #, and % (defined in Telcordia GR-831-CORE).
Example 4-10 Adding a New User
ash:hostname:ONS15216 EDFA2> user entry create janedoe read_write
New Password =
*********
Confirm New Password =
*********
4.11 Save Changes
To ensure that the provisioning changes are set, you must save your changes prior to terminating the session. To save changes, use the snmp attribute set local cerent15216EdfaOpSaveConfig perform command ( Example 4-11).
Example 4-11 Saving Changes
ash:hostname:ONS15216 EDFA2> snmp attribute set local cerent15216EdfaOpSaveConfig perform
Most SNMP configuration attributes require the above save command before terminating the session (does not apply to TL1 shell). The exceptions to this save requirement (the attributes that are automatically saved) are shown below:
•cerent15216EdfaPowerBusMode
•cerent15216EdfaPowerBusDCVoltageMin
•cerent15216EdfaPowerBusDCVoltageMax
•cerent15216EdfaConstGainOverallGain
•cerent15216EdfaVariableGainPreAttenuation
•SromIpMgmtGroup attributes:
–cerent15216EdfaSromIpMgmtEnetAddress
–cerent15216EdfaSromIpMgmtEnetSubNetMask
–cerent15216EdfaSromIpMgmtDefaultRouterAddress
–cerent15216EdfaSromIpMgmtHostName
•BootTable attributes:
–cerent15216EdfaBootModuleIndex
–cerent15216EdfaBootEntryIndex
–cerent15216EdfaBootType
–cerent15216EdfaBootIpAddress
–cerent15216EdfaBootFileName
4.12 Log Off
At the end of a session, the user must log off of the ONS 15216 EDFA2. To log off, use the logoff command. This is shown in Example 4-12.
Example 4-12 Logging Off
ash:hostname:ONS15216 EDFA2> logoff
4.13 Recover Default Password
If the root password for CISCO15 is lost, there is a procedure to reset it to regain full administrative control of the ONS 15216 EDFA2. The user must be connected to the ONS 15216 EDFA2 by serial communication, perform a hard power reset, and then performs a series of commands within 60 seconds of rebooting, according to the following procedure.
Warning The ONS 15216 EDFA2 ceases its optical amplification function when power is off during this process. Traffic should be rerouted before this procedure begins.
Note If the ONS 15216 EDFA2 firmware is not version 2.1.0 or greater, the CISCO15 user resets to read_write access level, not read_write_admin, which has full administrative control. Contact Cisco TAC for assistance.
Step 1 Connect to the EIA/TIA-232 port.
Step 2 Open HyperTerminal. (HyperTerminal can be found in the Microsoft Windows Accessories menu.)
Step 3 Perform hard power reset of the ONS 15216 EDFA2 (disconnect and reconnect power).
Step 4 While the dots are present in the HyperTerminal window during the reboot process, enter Ctrl C on the keyboard.
The ONS 15216 EDFA2 should boot from the firmware image. The prompt is %.
Step 5 At the hostname prompt, enter the following command (must be done within 60 seconds of rebooting):
hostname:edfaboot%user passwd set CISCO15 default
Step 6 At the hostname prompt, enter the following command:
hostname:edfaboot%login CISCO15
Step 7 At the hostname prompt, enter the following command:
hostname:edfaboot%processor reset
After the processor reset, the default CISCO15 login password will be the default (the Enter key).