Release Notes address closed issues, caveats, and new features for the Cisco ONS 15200 SNM software. For detailed information regarding features, capabilities, and software introduced with this release, refer to the documents listed in the "Related Documentation" section. For the most current version of the Release Notes for Cisco ONS 15200 Release 1.1, visit the following URL:
http://www.cisco.com/univercd/cc/td/doc/product/ong/15200/15200rnt/index.htm
July, 2002
New Features and Functionality
Obtaining Technical Assistance
This section documents changes that have been added to the Release Notes for Cisco ONS 15200 Release 1.1 since the production of the Cisco ONS 15200 System Software CD for Release 1.1.
This document details additions, changes, and removals since release 1.1(2)
The following new features and functionality have been added to the ONS 15200 Software Release 1.1(3) software.
The Element ID has been replaced with the CLIP name to improve event log information.
Only the root cause of a fault is reported, subsequent fault(s) will be suppressed and displayed with normal, if read by the user.
The limitation of the maximum number of 10 simultaneous PM sessions has been increased to 64 simultaneous PM sessions.
A new web interface page has been added to show the power levels for all CLIPs managed by the SNM.
The global alarms Web interface page now provides links to alarming CLIPs.
The main path view Web interface page now provides active path information.
When you try to create more than 100 users from the Web interface or the CLI, an error message appears notifying you of this limitation.
The users are now presented in alphabetic order in the Web interface and the CLI.
The Netscape System Explorer applet resizing problems (Win/Unix) has been resolved.
The Web interface now reports qdbs.cfg version mismatch and Network configuration mismatch errors.
The allowed ranges for the thresholds are presented under the view where you change the threshold. It is also possible to change all thresholds in the same operation.
The software CLI enables the operator to re-read the MCU backplane jumper settings by entering configure MCU xxxxx, and then applying upload.
After you have performed remove SNM_xxxxx or insert SNM_xxxx, there is no need to perform a commit SNM SNM_xxxxx, because this is now done automatically.
This section describes ONS 15200 system limitations and restrictions.
The role of the CIM is to reflect the summary status of the CLIPs that the SNM manages.
CLIPs that the SNM observes but not manages, are not included in the summary calculation, even if those CLIPs are located in the same MCU as the NCB.
The CIM status displayed in the Web interface and the real status will not be the same in one casewhen viewing an MCU with a remote NCB. The CIM is not lit in the Web interface.
The MCU and SCU summary pages show the NAM status. The NAM status viewed in the Web interface will correspond to the status displayed by the real NAM with two exceptions:
1. The Web interface will not show the real status if the SNM only observes the CLIP.
2. There are discrepancies related to the FW version.
High Alarm | High Warning | Low warning | Low Alarm | |
---|---|---|---|---|
Client laser bias current | Red | Yellow | Yellow | Red |
Client input power | Red | Yellow | Yellow | Red |
DWDM Peltier element current | Yellow1 | Yellow | Yellow | Yellow1 |
DWDM laser temperature | Red | Yellow | Yellow | Red |
DWDM laser bias current | Red | Yellow | Yellow | Red |
DWDM A input power | Red2 | Yellow | Yellow | Standby: Yellow Active: Red |
DWDM laser output power | Red | Yellow | Yellow | Red |
DWDM B input power | Red2 | Yellow | Yellow | Standby: Yellow Active: Red |
Board temperature | Red | Yellow | Yellow | Red |
The following procedure describes how to configure a new 1.1 system from scratch. This procedure must be repeated for all NCBs in the system.
Step 2 Verify that you have the proper NCB (P/N and Rev no.) SNM Release 1.1(3) requires a minimum NCB board level of 800-09474-02.
a. Enter configure system mode by typing config system and press Enter.
b. Type version and press Enter
c. Verify that the NCB part number shown has -02 at the end. If it has -01, contact TAC to get the board replaced.
d. Type exit and press Enter.
Step 3 Type show inventory and press Enter. The only thing that should show up is the NCB board you are connected to. Observe the name of the NCB/SNM.
Step 4 Verify the name of the NCB/SNM. If the name is SNM_0, this NCB board can not run 1.1(3) software properly. Contact TAC to get the NCB board replaced.
Step 5 Set unitid on the NCB, by configuring the SNM. At the NCB:> prompt, type configure SNM SNM_xxxxx and press Enter.
Step 6 Set unitid to either SNM_1 or SNM_2, according to preference. If two NCBs share the same CAN bus, they must have different unitids.
a. Type unitid SNM_1 or unitid SNM_2 and press Enter.
b. Type commit and press Enter to save the changes to the file.
c. Type exit when finished to get back to the login prompt.
Step 7 After about 15 seconds, type show inventory and press Enter to display the inventory. This should allow the system enough time to collect the inventory information.
Step 8 Set the SNM to primary, secondary, or unassigned manager according to your preference.
To assign a primary manager:
a. At the NCB:> prompt, go into network configuration mode by typing configure network and press Enter.
b. Type configure CLIP CLIP_xxxxx and press Enter.
c. Type primary this and press Enter.
d. Type exit and press Enter to get back to configure network mode.
To assign a secondary manager:
a. If not in network configuration mode, enter it by typing configure network and press Enter at the prompt.
b. Type configure CLIP CLIP_xxxxx and press Enter.
c. Type secondary this and press Enter.
d. Type exit and press Enter to get back to configure network mode.
Step 9 Define your MCUs/SCUs (containers).
To create an MCU or SCU from configuration network mode, type create mcu <neid> or create scu <neid> and press Enter. (<neid> is an identifier, an arbitrary number unique for the SCU/MCU.)
To name the MCU:
a. At the mcu_x:# prompt, type name <your_choice_of_MCU_name> and press Enter.
b. Type commit and press Enter to save the changes to the file.
c. Type exit and press Enter to get back to the network configuration menu.
To name the SCU:
a. At the scu_z:# prompt, type name <your_choice_of_SCU_name> and press Enter.
b. Type commit and press Enter to save the changes to the file.
c. Type exit and press Enter to get back to the network configuration menu.
Step 10 Insert your CLIPs and SNMs into the defined containers.
From the configuration network mode, insert your CLIPs and SNMs assigned to a particular MCU by performing the following:
a. Type configure mcu <mcuname_of_mcu_to_be_configured> and press Enter.
b. Type insert CLIP_xxxxx and press Enter, and repeat this step for all CLIPs concerned.
c. Type insert SNM_yyyyy and press Enter if applicable.
d. Type commit and press Enter to save the changes to the file.
e. Type exit and press Enter to get to network configuration mode
f. Repeat for all MCUs.
From the configuration network mode, insert the CLIP assigned to a particular SCU by performing the following:
a. Type configure scu <scuname_of_scu_to_be_configured> and press Enter.
b. Type insert CLIP_xxxxx and press Enter.
c. Type commit and press Enter to save the changes to the file.
d. Type exit and press Enter to get to network configuration mode
e. Repeat for all SCUs.
Step 11 Optional CLIP and SNM name assignment.
To assign a CLIP name:
a. At the configure network prompt, type configure CLIP CLIP_xxxxx and press Enter.
b. Type name <what_you_want_the_CLIP_to_be_called> and press Enter.
c. Type commit and press Enter to save the changes to the file.
d. Type exit and press Enter.
e. Repeat for all CLIPs you want to assign a name.
To assign a SNM name:
a. At the configure network prompt, type configure SNM SNM_yyyyy and press Enter.
b. Type name <what_you_want_the_SNM_to_be_called> and press Enter.
c. Type commit and press Enter to save the changes to the file.
d. Type exit and press Enter.
Step 12 At the configure network prompt, issue a commit network and press Enter to create a network.cfg file for the network.
Step 13 Type show inventory and press Enter. Verify that all of the expected hardware in your system appears in the inventory.
Review the notes listed below before deploying the ONS 15200. Caveats with DDTS bug tracking numbers are known system limitations that are scheduled to be addressed in a subsequent release. Caveats without DDTS bug tracking numbers are provided to point out procedural or situational considerations when deploying the product.
Component: SNM software
Detail: The CLI and Web interface do not clear alarms even though the value is between lwt and hwt.
Workaround: Perform an upload.
Resolution: This issue will be resolved in a future release.
Component: Software documentation
Detail: The Release 1.1 documentation does not include a procedure describing how to add SCUs or CLIPs to an existing ring.
Workaround: Use the following Web interface procedure to add an SCU and CLIP to an existing ring.
1. Use the Web interface to login to the NCB.
3. At the blank, last line of the table, enter the SCU name and NE ID and click Submit.
4. Click on the newly created SCU to view the SCU information. In the lower half of the screen you can insert a CLIP in the SCU.
5. Click Insert. A CLIP will appear in the lower half of the screen.
6. Select the new CLIP and click Submit.
7. Repeat steps 2 through 6 for each additional CLIP you wish to add to the SCU.
Resolution: This procedure will be added to the documentation in a future revision.
Component: SNM software
Detail: When a CLIP is removed from an MCU or when the DWDM-side fiber is disconnected, the SNMP agent sends an OutOfService trap. When the CLIP is reinserted or the fiber is reconnected, the SNMP agent sends an InService trap. After receiving the trap, CTM tries to upload inventory and alarm information for the CLIP. Because the Var Binds are null, CTM cannot upload the information successfully.
Workaround: If the alarm information is incorrect, mark the NE as Under Maintenance and click Save. Then, mark it as In Service and click Save.
Resolution: This issue will be resolved in a future release.
Component: Software documentation
Detail: When turning up a path between two CLIPs, it is possible that the clients may not be able to communicate with each other because of datarate mismatch.
Workaround: If you wish to change the CLIP datarate, always start with the CLIP that is the farthest away from the NCB.
It is preferable to remove the client input signal before changing data rate or to change the datarate on a path level rather than a CLIP level.
Resolution: This note will be added to the documentation in a future revision.
Component: NEC firmware
Detail: Some pairs of clips show toggling QPP alarms if the signal between them is Gigabit Ethernet, but
datarate is set to STM-16/OC-48 in the management interface (CLI). When the expected datarate is set incorrectly, the clock and data recovery function will not work. It will transmit noise, which will modulate the DWDM signal and thus disturb the QPP signal directly.
Workaround: Be sure to always set the datarate correctly.
Resolution: None.
Component: NEC firmware
Detail: Alarms are not cleared in WEB and CLI for values that are around 1.5 dB from thresholds in normal operating range. To avoid flickering alarms, threshold hysteresis is implemented. The present value is fluctuating above and below the threshold during the time of the hysteresis, 2 seconds.
Workaround: None.
Resolution: This issue will be resolved in a future release.
Component: NEC firmware
Detail: The ONS 15200 system uses in-band signaling (QPP) for management communication. A protected CLIP transmits identical signals on both the alternative connections, including QPP. QPP is terminated/re-transmitted in each node, including the regenerator nodes. Unfortunately the QPP protocol definition does not currently include information, identifying to which of the alternative paths a message was addressed. Thus there is a possible addressing conflict. A further problem is that a protected CLIP assumes that it receives identical QPP messages on both the incoming QPP links, which is not the case when there are regenerating CLIPs along the alternative paths. The CLIP will randomly pick packets from either of the incoming links. Due to the above described problems it is not currently possible to manage a network with regeneration in protected paths.
Workaround: None in SNM 1.1(1). In 1.1(2) it is possible to set pinglevel to one, thereby limiting management to one CAN bus. An NCB is required in each node.
Resolution: This issue will be resolved in a future release.
Component: Clip-board
Detail: No CLEI label on clip front. All current clips are affected.
Workaround: None.
Resolution: This issue will be resolved in a future release.
Component: Web interface
Detail: When you disconnect a patch cord to an active path with no standby and then look at the clip status on a clip one QPP away, the Web interface logged out.
Workaround: Login again.
Resolution: This issue will be resolved in a future release.
Component: SNM software
Detail: Several NCBs can be configured (configure snm snm_xxxxx) with identical unit ID. No check or negotiation is done by the SNM software to verify that the unit ID is not already used.
Workaround: Make sure each unit ID is only used once.
Resolution: This issue will be resolved in a future release.
Component: SNM software
Detail: CIM board LED does not exhibit expected red LED when the System has data rate mismatch alarm on a path.
Workaround: None.
Resolution: This issue will be resolved in a future release.
Component: Web interface
Detail: A reset of the Daylight Savings Time on and off configuration after a reboot occurs when the configuration of Daylight Savings Time on and off is executed from the Web interface.
Workaround: Set the Daylight Savings Time on and off from the CLI.
Resolution: This issue will be resolved in a future release.
Component: SNM software
Detail: An NCB can be displayed with a red LED (on web), with only two minor alarms in the system (protected clip with loss of power on one side). The NCB (snm) itself is displayed with NE Status normal in the snm_name Summary page. Under some circumstances, the presented alarm level is too high and under others the level is too low.
Workaround: None.
Resolution: This issue will be resolved in a future release.
Component: SNM software
Detail: With alarms client Rx power, client laserbias, dwdm loc, dwdm rxpower, dcn qpp and dcn qppb, the NAM under the clip exhibit red LED, but the CIM exhibit yellow LED.
Workaround: None.
Resolution: This issue will be resolved in a future release.
Component: SNM software
Detail: The CIM did not present the right status when Client Rx Power = High warning was created on a CLIP. Additionally, the Web interface presented the wrong CIM status as well.
Workaround: None.
Resolution: This issue will be resolved in a future release.
Component: CLI software
Detail: When performing a commit network and show discrepancy, you do not get the empty set. Clips with names other than their native name (i.e. clip_xxxxx) will show up as discrepancies.
Workaround: None.
Resolution: This issue will be resolved in a future release.
Component: Web interface
Detail: Under special circumstances, the Web interface locks. You are unable to login to the system via the Web interface. This occurs when there is a lot of internal traffic in the system and if you cycle through pages too quickly.
Workaround: Use the CLI to unlock the Web interface by performing a manual reboot with the CLI.
Resolution: This issue will be resolved in a future release.
Component: Web interface
Detail: When working in the Web interface, a path was shown as a bold line instead of a thin line when one of the paths around the ring was lost.
Workaround: None.
Resolution: This issue is resolved in release 1.1(3).
Component: NEC firmware
Detail: Clips on pinglevel four can not be managed from the NCB. Appears in systems with mixed FW versions 0.3(8) and 1.2(2), if the path from the NCB to the clip starts via FW version 0.3(8), and passes through a clip on the second CAN bus (pinglevel three) with FW version 1.2(2). The clip talking to this clip will not be managable.
Workaround: Avoid mixing firmware 0.3(8) and 1.2(2) as described.
Resolution: This issue is resolved in release 1.1(3).
Component: SNM software
Detail: If you disconnect the DWDM-side fiber from a clip in the MCU where the NCB sending traps resides, the associated remote CLIP will generate a DwdmLOC alarm with a severity of Unknown. The alarm appears in the Alarm Log, but not in the Alarm Browser.
Workaround: Using CTM, mark the NE as Under Maintenance and click Save. Then, mark the NE as In Service and click Save.
Resolution: This issue is resolved in release 1.1(3).
Component: SNM software
Detail: A clipDwdmRxPower-Severity alarm is sent for a protected CLIP. A corresponding cease will never be sent for this alarm. This problem occurs if you disconnect the DWDM-side fiber for a protected CLIP. The SNMP agent sends a clipDwdmRxPower-Severity alarm for the associated SCU.
Workaround: Using CTM, wait several minutes; then, mark the NE as Under Maintenance and click Save. Then, mark it as In Service and click Save.
Resolution: This issue is resolved in release 1.1(3).
Component: SNM software
Detail: You are not able to turn off Daylight Savings Time (DLST_on) after have configured it to be on.
Workaround: Set DLST_on equal to DLST_off.
Resolution: This issue is resolved in release 1.1(3).
Component: SNM software
Detail: Malformed SNMP traps can cause NCB resets. See PSIRT notification on SNMP vulnerabilities.
Workaround: Do not activate the SNMP interface i.e don't create any communities via the CLI interface.
Resolution: This issue is resolved in release 1.1(3).
Component: Web interface
Detail: The yellow LED is lit on the CIM, even though no active alarms were raised in CLI, Web interface and MM.
Workaround: None.
Resolution: This issue is resolved in release 1.1(3).
Component: Web interface
Detail: The CIM card is not marked yellow or red in the Web interface during testing.
Workaround: None.
Resolution: This issue is resolved in release 1.1(3).
Component: SNM software
Detail: The configuration of the unitid is not saved when performing a reboot of the system.
Workaround: None.
Resolution: This issue is resolved in release 1.1(3).
Component: CLI software
Detail: In the web browser all users are displayed, but in the CLI only 100 users are displayed. More than 100 users have been created. (This should actually be disallowed by the system, but is possible due to a bug.) Using the CLI command 'sh user' exactly 100 users are shown. The oldest users are not shown.
Workaround: Delete users. The system is not supposed to support more than 100 users!
Resolution: This issue is resolved in release 1.1(3).
Component: Web interface
Detail: The web browser gives you the choice to insert an NCB into an MCU, although the rack ID of the NCB does not match the rack ID of the MCU. After pressing the insert button for a slot in an MCU the pop-up showing the possible boards to insert in that slot is activated. The pop-up list gives alternatives, which should not be allowed as the corresponding boards have incorrect values for the rack ID attributes.
Workaround: None.
Resolution: This issue is resolved in release 1.1(3).
Component: SNM software
Detail: When setting the datarate on the path (i.e. any clip-clip connection) to Gigabit Ethernet or STM-16/OC-48 from the Web or CLI interfaces, the GUI shows that a change occurs. However, if an actual Gigabit Ethernet signal is applied, no traffic will pass through. All required actions in software have not been carried out properly.
Workaround: Set the datarate on the individual clips, starting with the clip farthest away from the NCB.
As an alternative for Gigabit Ethernet (not STM-16/OC-48), the 2R/3R boards can be set to operate in pass-through mode. For large systems where multiple regenerations are needed, this can not be done because only one regeneration is supported in 2R/3R mode.
Resolution: This issue is resolved in release 1.1(3).
Component: CLI software
Detail: When an administrative user sets the parameter pwd_set no, there is no change in the file where the information is stored (snm.cfg). If the parameter pwd_set no is implemented, it will only be effective as long as reboot or power cycling is avoided. Since the operator is allowed to reboot the system, an operator not allowed to change his/her password can do so by first rebooting and then, when the system has reverted to the default parameter pwd_set yes, the user can reset his/her password.
Workaround: Change and replace the snm.cfg file. To change the file: use the ftp command get to copy the snm.cfg file to a computer (requires admin privileges), replace the line pwd_set yes with the line pwd_set no, and replace the snm.cfg file on the NCB board (with the ftp command put). Doing so carries out the intended CLI function.
If it later is preferred to go back to the initial setting of pwd_set yes, the process above has to be performed to write pwd_set yes in the snm.cfg file and put the file back onto the NCB board.
Resolution: This issue is resolved in release 1.1(3).
For additional information on the Cisco ONS 15200, refer to the following documents.
Cisco ONS 15200 Product Description
Cisco ONS 15200 Module Handbook
Cisco ONS 15200 Installation, Setup, and Test Manual
Cisco ONS 15200 Maintenance Manager Installation and Operations Guide
Cisco ONS 15200 Web Interface Software User Manual
Cisco ONS 15200 Command Line Interface Manual
The following sections provide sources for obtaining documentation from Cisco Systems.
You can access the most current Cisco documentation on the World Wide Web at the following sites:
Optical networking-related documentation, including the Cisco ONS 15200 Release Notes, is available in a CD-ROM package that ships with your product. The Optical Networking Product Documentation CD-ROM, a member of the Cisco Connection Family, is updated as required. Therefore, it might be more current than printed documentation. To order additional copies of the Optical Networking Product Documentation CD-ROM, contact your local sales representative or call customer service. The CD-ROM package is available as a single package or as an annual subscription. You can also access Cisco documentation on the World Wide Web at http://www.cisco.com, http://www-china.cisco.com, or http://www.europe.cisco.com.
Cisco documentation is available in the following ways:
If you are reading Cisco product documentation on the World Wide Web, you can submit technical comments electronically. Click Feedback in the tool bar and select Documentation. After you complete the form, click Submit to send it to Cisco.
You can e-mail your comments to bug-doc@cisco.com.
To submit your comments by mail, use the response card behind the front cover of your document, or write to the following address:
Attn Document Resource Connection
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-9883
We appreciate your comments.
Cisco provides Cisco.com as a starting point for all technical assistance. Customers and partners can obtain documentation, troubleshooting tips, and sample configurations from online tools. For Cisco.com registered users, additional troubleshooting tools are available from the TAC website.
Cisco.com is the foundation of a suite of interactive, networked services that provides immediate, open access to Cisco information and resources at anytime, from anywhere in the world. This highly integrated Internet application is a powerful, easy-to-use tool for doing business with Cisco.
Cisco.com provides a broad range of features and services to help customers and partners streamline business processes and improve productivity. Through Cisco.com, you can find information about Cisco and our networking solutions, services, and programs. In addition, you can resolve technical issues with online technical support, download and test software packages, and order Cisco learning materials and merchandise. Valuable online skill assessment, training, and certification programs are also available.
Customers and partners can self-register on Cisco.com to obtain additional personalized information and services. Registered users can order products, check on the status of an order, access technical support, and view benefits specific to their relationships with Cisco.
To access Cisco.com, go to the following website:
The Cisco TAC website is available to all customers who need technical assistance with a Cisco product or technology that is under warranty or covered by a maintenance contract.
If you have a priority level 3 (P3) or priority level 4 (P4) problem, contact TAC by going to the TAC website:
P3 and P4 level problems are defined as follows:
In each of the above cases, use the Cisco TAC website to quickly find answers to your questions.
To register for Cisco.com, go to the following website:
http://www.cisco.com/register/
If you cannot resolve your technical issue by using the TAC online resources, Cisco.com registered users can open a case online by using the TAC Case Open tool at the following website:
http://www.cisco.com/tac/caseopen
If you have a priority level 1 (P1) or priority level 2 (P2) problem, contact TAC by telephone and immediately open a case. To obtain a directory of toll-free Cisco TAC telephone numbers for your country, go to the following URL:
http://www.cisco.com/warp/public/687/Directory/DirTAC.shtml
This document is to be used in conjunction with the documents listed in the "Related Documentation" section.
CCIP, the Cisco Powered Network mark, the Cisco Systems Verified logo, Cisco Unity, Follow Me Browsing, FormShare, Internet Quotient, iQ Breakthrough, iQ Expertise, iQ FastTrack, the iQ Logo, iQ Net Readiness Scorecard, Networking Academy, ScriptShare, SMARTnet, TransPath, and Voice LAN are trademarks of Cisco Systems, Inc.; Changing the Way We Work, Live, Play, and Learn, Discover All That's Possible, The Fastest Way to Increase Your Internet Quotient, and iQuick Study are service marks of Cisco Systems, Inc.; and Aironet, ASIST, BPX, Catalyst, CCDA, CCDP, CCIE, CCNA, CCNP, Cisco, the Cisco Certified Internetwork Expert logo, Cisco IOS, the Cisco IOS logo, Cisco Press, Cisco Systems, Cisco Systems Capital, the Cisco Systems logo, Empowering the Internet Generation, Enterprise/Solver, EtherChannel, EtherSwitch, Fast Step, GigaStack, IOS, IP/TV, LightStream, MGX, MICA, the Networkers logo, Network Registrar, Packet, PIX, Post-Routing, Pre-Routing, RateMUX, Registrar, SlideCast, StrataView Plus, Stratm, SwitchProbe, TeleRouter, and VCO are registered trademarks of Cisco Systems, Inc. and/or its affiliates in the U.S. and certain other countries.
All other trademarks mentioned in this document or Web site are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other company. (0203R)
Copyright © 2002, Cisco Systems, Inc.
All rights reserved.
Posted: Thu Jul 18 11:10:34 PDT 2002
All contents are Copyright © 1992--2002 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.