cc/td/doc/product/mels/cmet1500
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

NEMI Software Specifications

NEMI Software Specifications

This appendix lists the hardware and software specifications of the NEMI, settings for an external modem, and the SNMP protocols for the wavelength channel modules (WCMs). This appendix includes the following sections:

NEMI Software

The NEMI software consists of the following:

The modem should be connected by a cable that can transmit all the signals listed in Table C-1 to the NEMI DB9 serial connector.


Table C-1: DB9 Serial Connector Signal
Signal Description Pin

RxD

Receive data

2

TxD

Transmit data

3

DTR

Data terminal ready

4

GND

Signal ground

5

DSR

Data set ready

6

RTS

Request To Send

7

CTS

Clear To Send

8

RI

Ring indicator

9

SNMP Features of WCMs

When a WCM is installed, the data marked "Automatic Read" is automatically supplied to the NEMI. See Table C-2 through Table C-7.


Table C-2: Configuration Data
Feature SNMP Management

Serial no.

Automatic Read

Channel location

Automatic Read

Clock (yes/no)

Automatic Read

Cooled laser (yes/no)

Automatic Read

Power supply available (yes/no)

Automatic Read

Fan available (yes/no)

Automatic Read


Table C-3: Monitoring of Technical Operation Conditions
Feature SNMP Management

Power supply failure (yes/no)

Automatic Read

Fan failure (yes/no)

Automatic Read

Environmental temperature (of converter card)

Automatic Read

Laser temperature (stabilized laser only)

Automatic Read

Laser current (stabilized laser only)

Automatic Read


Table C-4: WCM Receivers and Transmitters
Receiver or Transmitter Feature SNMP Management

Local receiver

Loss of signal

Read

Remote receiver

Loss of signal

Read

Local transmitter

Status of laser (on/off)

Read

Remote transmitter

Status of laser (on/off)

Read


Table C-5: Low-Speed Multiclock
Feature SNMP Management

Enable (on/off)

Read/Write1

Read clock setting (125, 155, or 200, 266) Mbps

Read

Set clock to (125, 155, 200, 266) Mbps

Write1

Clock Synchronized (yes/no)

Read

1This option is not writable by SNMP, but by management programs.


Table C-6: High-Speed Multiclock
Feature SNMP Management

Enable (on/off)

Read/Write1

Read clock setting (155, 622, 1244, 1062, 1250) Mbps

Read

Set clock to (155, 622, 1244, 1062, 1250) Mbps

Write1

Clock synchronized (yes/no)

Read

1This option is not writable by SNMP, but by management programs.


Table C-7: Fixed Clock Option
Feature SNMP Management

Enable (on/off)

Not supported

Read clock setting

Read

Set clock

Not supported

Clock synchronized

Read


hometocprevnextglossaryfeedbacksearchhelp
Posted: Thu Aug 9 15:58:54 PDT 2001
All contents are Copyright © 1992--2001 Cisco Systems, Inc. All rights reserved.