This appendix lists the hardware and software specifications of the NEMI, settings for an external modem, and the SNMP protocols for the wavelength channel modules (WCMs). This appendix includes the following sections:
The NEMI software consists of the following:
Note NEMI software can be upgraded through Ethernet or serial ports. Flash memory can be reprogrammed through an Ethernet or serial port connection. Refer to the Cisco Metro 1500 Series Software Configuration Guide for more NEMI information. |
The modem should be connected by a cable that can transmit all the signals listed in Table C-1 to the NEMI DB9 serial connector.
Signal | Description | Pin |
---|---|---|
RxD | Receive data | 2 |
TxD | Transmit data | 3 |
DTR | Data terminal ready | 4 |
GND | Signal ground | 5 |
DSR | Data set ready | 6 |
RTS | Request To Send | 7 |
CTS | Clear To Send | 8 |
RI | Ring indicator | 9 |
When a WCM is installed, the data marked "Automatic Read" is automatically supplied to the NEMI. See Table C-2 through Table C-7.
Feature | SNMP Management |
---|---|
Serial no. | Automatic Read |
Channel location | Automatic Read |
Clock (yes/no) | Automatic Read |
Cooled laser (yes/no) | Automatic Read |
Power supply available (yes/no) | Automatic Read |
Fan available (yes/no) | Automatic Read |
Feature | SNMP Management |
---|---|
Power supply failure (yes/no) | Automatic Read |
Fan failure (yes/no) | Automatic Read |
Environmental temperature (of converter card) | Automatic Read |
Laser temperature (stabilized laser only) | Automatic Read |
Laser current (stabilized laser only) | Automatic Read |
Receiver or Transmitter | Feature | SNMP Management |
---|---|---|
Local receiver | Loss of signal | Read |
Remote receiver | Loss of signal | Read |
Local transmitter | Status of laser (on/off) | Read |
Remote transmitter | Status of laser (on/off) | Read |
Feature | SNMP Management |
---|---|
Enable (on/off) | Read/Write1 |
Read clock setting (125, 155, or 200, 266) Mbps | Read |
Set clock to (125, 155, 200, 266) Mbps | Write1 |
Clock Synchronized (yes/no) | Read |
1This option is not writable by SNMP, but by management programs. |
Feature | SNMP Management |
---|---|
Enable (on/off) | Read/Write1 |
Read clock setting (155, 622, 1244, 1062, 1250) Mbps | Read |
Set clock to (155, 622, 1244, 1062, 1250) Mbps | Write1 |
Clock synchronized (yes/no) | Read |
1This option is not writable by SNMP, but by management programs. |
Feature | SNMP Management |
---|---|
Enable (on/off) | Not supported |
Read clock setting | Read |
Set clock | Not supported |
Clock synchronized | Read |
Posted: Thu Aug 9 15:58:54 PDT 2001
All contents are Copyright © 1992--2001 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.