cc/td/doc/product/mels/15540x/12_2_sv
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table Of Contents

Configuring Point-to-Point Topologies

About Point-to-Point Topologies

Multiple Trunk Support

Configuring a Point-to-Point Topology with Splitter Protection

Patch Connections

Transparent Interfaces

APS

Configuring a Point-to-Point Topology with Line Card Protection

Node 1

Configuring an Unprotected Point-to-Point Topology

Patch Connections

Transparent Interfaces


Configuring Point-to-Point Topologies


This chapter describes how to configure point-to-point topologies. This chapter contains the following sections:

About Point-to-Point Topologies

Configuring a Point-to-Point Topology with Splitter Protection

Configuring a Point-to-Point Topology with Line Card Protection

Configuring an Unprotected Point-to-Point Topology

About Point-to-Point Topologies

In a point-to-point topology, two Cisco ONS 15540 ESPx systems are connected to each other in the network. Each of the systems originates and terminates all configured channels. You can use splitter protection to protect against fiber failure, or line card protection to protect against both the fiber and transponder failures. To also protect against client failure, you can implement protection on the client equipment itself.


Note Client protection implementation is beyond the scope of this document.


Up to 32 client signals in splitter protection mode, or 16 client signals in line card protection mode, are optically multiplexed at each end and are multiplexed onto a single fiber pair. Figure 9-1 shows an example of this topology using two DWDM fiber links, one working and one protection.

Figure 9-1 Protected Point-to-Point Topology Example

Figure 9-2 shows an example of an unprotected point-to-point topology using one unprotected DWDM fiber link.

Figure 9-2 Unprotected Point-to-Point Topology Example

Point-to-point topologies have many common applications, including extending the reach of Gigabit Ethernet or SONET in long-haul transport.


Note Point-to-point topologies support an intermediate add/drop node only in an unprotected configuration. If add/drop with protection is required, a ring configuration should be used.


For more information on point-to-point topologies, refer to the Cisco ONS 15540 ESPx Planning Guide.

Multiple Trunk Support

You can connect two or more trunk fibers to you Cisco ONS 15540 ESPx and support multiple point-to-point topologies or a combination of point-to-point topologies and ring topologies. The configuration of the shelf is the same for all trunks except for the OSC support. If one of the topologies uses the OSC as the APS message channel, it is unavailable for management for the other topologies. In that case, you can use either the in-band message channel, if available, or an IP connection.

Configuring a Point-to-Point Topology with Splitter Protection

Figure 9-3 shows how the modules are installed in the shelf for a 32-channel point-to-point topology. Thirty-two client signals of any supported protocol are carried over the trunk fiber, which is protected. This scenario assumes that splitter protection is being used and the working path is through slot 0 on both nodes.

Figure 9-3 Shelf Configuration for Splitter Protected 32-Channel Point-to-Point Topology

Figure 9-4 shows how the terminal mux/demux modules are cabled for the 32-channel splitter protected point-to-point configuration.

Figure 9-4 Terminal Mux/Demux Module Cabling with OSC for Splitter Protected 32-Channel Point-to-Point Topology

Patch Connections

Node1# configure terminal
Node1(config)# patch wave 0 oscfilter 0/0
Node1(config)# patch wave 1 oscfilter 1/0

Node1(config)# patch wavepatch 2/0/0 filter 0/0/0
Node1(config)# patch wavepatch 2/1/0 filter 0/0/1
Node1(config)# patch wavepatch 2/2/0 filter 0/0/2
Node1(config)# patch wavepatch 2/3/0 filter 0/0/3
Node1(config)# patch wavepatch 2/0/1 filter 1/0/0
Node1(config)# patch wavepatch 2/1/1 filter 1/0/1
Node1(config)# patch wavepatch 2/2/1 filter 1/0/2
Node1(config)# patch wavepatch 2/3/1 filter 1/0/3

Node1(config)# patch wavepatch 3/0/0 filter 0/0/4
Node1(config)# patch wavepatch 3/1/0 filter 0/0/5
Node1(config)# patch wavepatch 3/2/0 filter 0/0/6
Node1(config)# patch wavepatch 3/3/0 filter 0/0/7
Node1(config)# patch wavepatch 3/0/1 filter 1/0/4
Node1(config)# patch wavepatch 3/1/1 filter 1/0/5
Node1(config)# patch wavepatch 3/2/1 filter 1/0/6
Node1(config)# patch wavepatch 3/3/1 filter 1/0/7

Node1(config)# patch wavepatch 4/0/0 filter 0/0/8
Node1(config)# patch wavepatch 4/1/0 filter 0/0/9
Node1(config)# patch wavepatch 4/2/0 filter 0/0/10
Node1(config)# patch wavepatch 4/3/0 filter 0/0/11
Node1(config)# patch wavepatch 4/0/1 filter 1/0/8
Node1(config)# patch wavepatch 4/1/1 filter 1/0/9
Node1(config)# patch wavepatch 4/2/1 filter 1/0/10
Node1(config)# patch wavepatch 4/3/1 filter 1/0/11

Node1(config)# patch wavepatch 5/0/0 filter 0/0/12
Node1(config)# patch wavepatch 5/1/0 filter 0/0/13
Node1(config)# patch wavepatch 5/2/0 filter 0/0/14
Node1(config)# patch wavepatch 5/3/0 filter 0/0/15
Node1(config)# patch wavepatch 5/0/1 filter 1/0/12
Node1(config)# patch wavepatch 5/1/1 filter 1/0/13
Node1(config)# patch wavepatch 5/2/1 filter 1/0/14
Node1(config)# patch wavepatch 5/3/1 filter 1/0/15

Node1(config)# patch wavepatch 8/0/0 filter 0/0/16
Node1(config)# patch wavepatch 8/1/0 filter 0/0/17
Node1(config)# patch wavepatch 8/2/0 filter 0/0/18
Node1(config)# patch wavepatch 8/3/0 filter 0/0/19
Node1(config)# patch wavepatch 8/0/1 filter 1/0/16
Node1(config)# patch wavepatch 8/1/1 filter 1/0/17
Node1(config)# patch wavepatch 8/2/1 filter 1/0/18
Node1(config)# patch wavepatch 8/3/1 filter 1/0/19

Node1(config)# patch wavepatch 9/0/0 filter 0/0/20
Node1(config)# patch wavepatch 9/1/0 filter 0/0/20
Node1(config)# patch wavepatch 9/2/0 filter 0/0/22
Node1(config)# patch wavepatch 9/3/0 filter 0/0/23
Node1(config)# patch wavepatch 9/0/1 filter 1/0/20
Node1(config)# patch wavepatch 9/1/1 filter 1/0/20
Node1(config)# patch wavepatch 9/2/1 filter 1/0/22
Node1(config)# patch wavepatch 9/3/1 filter 1/0/23

Node1(config)# patch wavepatch 10/0/0 filter 0/0/24
Node1(config)# patch wavepatch 10/1/0 filter 0/0/25
Node1(config)# patch wavepatch 10/2/0 filter 0/0/26
Node1(config)# patch wavepatch 10/3/0 filter 0/0/27
Node1(config)# patch wavepatch 10/0/1 filter 1/0/24
Node1(config)# patch wavepatch 10/1/1 filter 1/0/25
Node1(config)# patch wavepatch 10/2/1 filter 1/0/26
Node1(config)# patch wavepatch 10/3/1 filter 1/0/27

Node1(config)# patch wavepatch 11/0/0 filter 0/0/28
Node1(config)# patch wavepatch 11/1/0 filter 0/0/29
Node1(config)# patch wavepatch 11/2/0 filter 0/0/30
Node1(config)# patch wavepatch 11/3/0 filter 0/0/31
Node1(config)# patch wavepatch 11/0/1 filter 1/0/28
Node1(config)# patch wavepatch 11/1/1 filter 1/0/29
Node1(config)# patch wavepatch 11/2/1 filter 1/0/30
Node1(config)# patch wavepatch 11/3/1 filter 1/0/31

Transparent Interfaces

Node1(config)# interface transparent 2/0/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit

Node1(config)# interface transparent 2/1/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit
Node1(config)# interface wave 2/1
Node1(config-if)# laser frequency 192200
Node1(config-if)# exit

Node1(config)# interface transparent 2/2/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit

Node1(config)# interface transparent 2/3/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit
Node1(config)# interface wave 2/3
Node1(config-if)# laser frequency 192400
Node1(config-if)# exit

Node1(config)# interface transparent 3/0/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit

Node1(config)# interface transparent 3/1/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit
Node1(config)# interface wave 3/1
Node1(config-if)# laser frequency 192700
Node1(config-if)# exit

Node1(config)# interface transparent 3/2/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit

Node1(config)# interface transparent 3/3/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit
Node1(config)# interface wave 3/3
Node1(config-if)# laser frequency 192900
Node1(config-if)# exit

Node1(config)# interface transparent 4/0/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit

Node1(config)# interface transparent 4/1/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit
Node1(config)# interface wave 4/1
Node1(config-if)# laser frequency 193200
Node1(config-if)# exit

Node1(config)# interface transparent 4/2/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit

Node1(config)# interface transparent 4/3/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit
Node1(config)# interface wave 4/3
Node1(config-if)# laser frequency 193400
Node1(config-if)# exit

Node1(config)# interface transparent 5/0/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit

Node1(config)# interface transparent 5/1/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit
Node1(config)# interface wave 5/1
Node1(config-if)# laser frequency 193700
Node1(config-if)# exit

Node1(config)# interface transparent 5/2/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit

Node1(config)# interface transparent 5/3/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit
Node1(config)# interface wave 5/3
Node1(config-if)# laser frequency 193900
Node1(config-if)# exit

Node1(config)# interface transparent 8/0/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit

Node1(config)# interface transparent 8/1/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit
Node1(config)# interface wave 8/1
Node1(config-if)# laser frequency 194200
Node1(config-if)# exit

Node1(config)# interface transparent 8/2/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit

Node1(config)# interface transparent 8/3/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit
Node1(config)# interface wave 8/3
Node1(config-if)# laser frequency 194400
Node1(config-if)# exit

Node1(config)# interface transparent 9/0/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit

Node1(config)# interface transparent 9/1/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit
Node1(config)# interface wave 9/1
Node1(config-if)# laser frequency 194700
Node1(config-if)# exit

Node1(config)# interface transparent 9/2/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit

Node1(config)# interface transparent 9/3/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit
Node1(config)# interface wave 9/3
Node1(config-if)# laser frequency 194900
Node1(config-if)# exit

Node1(config)# interface transparent 10/0/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit

Node1(config)# interface transparent 10/1/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit
Node1(config)# interface wave 10/1
Node1(config-if)# laser frequency 195200
Node1(config-if)# exit

Node1(config)# interface transparent 10/2/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit

Node1(config)# interface transparent 10/3/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit
Node1(config)# interface wave 10/3
Node1(config-if)# laser frequency 195400
Node1(config-if)# exit

Node1(config)# interface transparent 11/0/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit

Node1(config)# interface transparent 11/1/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit
Node1(config)# interface wave 11/1
Node1(config-if)# laser frequency 195700
Node1(config-if)# exit

Node1(config)# interface transparent 11/2/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit

Node1(config)# interface transparent 11/3/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit
Node1(config)# interface wave 11/3
Node1(config-if)# laser frequency 195900
Node1(config-if)# exit

APS

Node1(config)# redundancy
Node1(config-red)# associate interface wavepatch */*/0 wavepatch */*/1 enable
Node1(config-red)# end

Node1# copy system:running-config nvram:startup-config

Repeat the entire preceding configuration on node 2.

Configuring a Point-to-Point Topology with Line Card Protection

Figure 9-5 shows how the modules are installed in the shelf for a 16-channel point-to-point topology with line card protection. Sixteen client signals of any supported protocol are carried over the trunk fiber, which is also protected.


Note For information about configuring nodes with more than 16 channels and line card protection, see "Configuring Dual Shelf Nodes."


Figure 9-5 Shelf Configuration for Line Card Protected 16-Channel Point-to-Point Topology

Figure 9-6 shows how the terminal mux/demux modules are cabled for the 16-channel line card protected point-to-point configuration.

Figure 9-6 Terminal Mux/Demux Module Cabling with OSC for Line Card Protected 16-Channel Point-to-Point Topology

Node 1

Patch Connections

Node1# configure terminal
Node1(config)# patch wave 0 oscfilter 0/0
Node1(config)# patch wave 1 oscfilter 1/1

Node1(config)# patch thru 0/0 wdm 0/1
Node1(config)# patch thru 0/1 thru 1/0
Node1(config)# patch wdm 1/0 thru 1/1

Node1(config)# patch wavepatch 2/0/0 filter 0/0/0
Node1(config)# patch wavepatch 2/1/0 filter 0/0/1
Node1(config)# patch wavepatch 2/2/0 filter 0/0/2
Node1(config)# patch wavepatch 2/3/0 filter 0/0/3

Node1(config)# patch wavepatch 3/0/0 filter 0/0/4
Node1(config)# patch wavepatch 3/1/0 filter 0/0/5
Node1(config)# patch wavepatch 3/2/0 filter 0/0/6
Node1(config)# patch wavepatch 3/3/0 filter 0/0/7

Node1(config)# patch wavepatch 4/0/0 filter 0/1/8
Node1(config)# patch wavepatch 4/1/0 filter 0/1/9
Node1(config)# patch wavepatch 4/2/0 filter 0/1/10
Node1(config)# patch wavepatch 4/3/0 filter 0/1/11

Node1(config)# patch wavepatch 5/0/0 filter 0/1/12
Node1(config)# patch wavepatch 5/1/0 filter 0/1/13
Node1(config)# patch wavepatch 5/2/0 filter 0/1/14
Node1(config)# patch wavepatch 5/3/0 filter 0/1/15

Node1(config)# patch wavepatch 8/0/0 filter 1/0/0
Node1(config)# patch wavepatch 8/1/0 filter 1/0/1
Node1(config)# patch wavepatch 8/2/0 filter 1/0/2
Node1(config)# patch wavepatch 8/3/0 filter 1/0/3

Node1(config)# patch wavepatch 9/0/0 filter 1/0/4
Node1(config)# patch wavepatch 9/1/0 filter 1/0/5
Node1(config)# patch wavepatch 9/2/0 filter 1/0/6
Node1(config)# patch wavepatch 9/3/0 filter 1/0/7

Node1(config)# patch wavepatch 10/0/0 filter 1/1/8
Node1(config)# patch wavepatch 10/1/0 filter 1/1/9
Node1(config)# patch wavepatch 10/2/0 filter 1/1/10
Node1(config)# patch wavepatch 10/3/0 filter 1/1/11

Node1(config)# patch wavepatch 11/0/0 filter 1/1/12
Node1(config)# patch wavepatch 11/1/0 filter 1/1/13
Node1(config)# patch wavepatch 11/2/0 filter 1/1/14
Node1(config)# patch wavepatch 11/3/0 filter 1/1/15

Transparent Interfaces

Node1(config)# interface transparent 2/0/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit

Node1(config)# interface transparent 2/1/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit
Node1(config)# interface wave 2/1
Node1(config-if)# laser frequency 192200
Node1(config-if)# exit

Node1(config)# interface transparent 2/2/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit

Node1(config)# interface transparent 2/3/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit
Node1(config)# interface wave 2/3
Node1(config-if)# laser frequency 192400
Node1(config-if)# exit

Node1(config)# interface transparent 3/0/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit

Node1(config)# interface transparent 3/1/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit
Node1(config)# interface wave 3/1
Node1(config-if)# laser frequency 192700
Node1(config-if)# exit

Node1(config)# interface transparent 3/2/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit

Node1(config)# interface transparent 3/3/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit
Node1(config)# interface wave 3/3
Node1(config-if)# laser frequency 192900
Node1(config-if)# exit

Node1(config)# interface transparent 4/0/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit

Node1(config)# interface transparent 4/1/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit
Node1(config)# interface wave 4/1
Node1(config-if)# laser frequency 193200
Node1(config-if)# exit

Node1(config)# interface transparent 4/2/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit

Node1(config)# interface transparent 4/3/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit
Node1(config)# interface wave 4/3
Node1(config-if)# laser frequency 193400
Node1(config-if)# exit

Node1(config)# interface transparent 5/0/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit

Node1(config)# interface transparent 5/1/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit
Node1(config)# interface wave 5/1
Node1(config-if)# laser frequency 193700
Node1(config-if)# exit

Node1(config)# interface transparent 5/2/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit

Node1(config)# interface transparent 5/3/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit
Node1(config)# interface wave 5/3
Node1(config-if)# laser frequency 193900
Node1(config-if)# exit

Node1(config)# interface transparent 8/0/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit

Node1(config)# interface transparent 8/1/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit
Node1(config)# interface wave 8/1
Node1(config-if)# laser frequency 192200
Node1(config-if)# exit

Node1(config)# interface transparent 8/2/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit

Node1(config)# interface transparent 8/3/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit
Node1(config)# interface wave 8/3
Node1(config-if)# laser frequency 192400
Node1(config-if)# exit

Node1(config)# interface transparent 9/0/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit

Node1(config)# interface transparent 9/1/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit
Node1(config)# interface wave 9/1
Node1(config-if)# laser frequency 192700
Node1(config-if)# exit

Node1(config)# interface transparent 9/2/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit

Node1(config)# interface transparent 9/3/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit
Node1(config)# interface wave 9/3
Node1(config-if)# laser frequency 192900
Node1(config-if)# exit

Node1(config)# interface transparent 10/0/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit

Node1(config)# interface transparent 10/1/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit
Node1(config)# interface wave 10/1
Node1(config-if)# laser frequency 193200
Node1(config-if)# exit

Node1(config)# interface transparent 10/2/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit

Node1(config)# interface transparent 10/3/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit
Node1(config)# interface wave 10/3
Node1(config-if)# laser frequency 193400
Node1(config-if)# exit

Node1(config)# interface transparent 11/0/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit

Node1(config)# interface transparent 11/1/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit
Node1(config)# interface wave 11/1
Node1(config-if)# laser frequency 1953700
Node1(config-if)# exit

Node1(config)# interface transparent 11/2/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit

Node1(config)# interface transparent 11/3/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit
Node1(config)# interface wave 11/3
Node1(config-if)# laser frequency 193900
Node1(config-if)# exit

APS

Use the following commands to configure y-cable protection. The working path is through slot 0.

Node1(config)# redundancy
Node1(config-red)# associate group channel1
Node1(config-red-aps)# aps working transparent 2/0/0
Node1(config-red-aps)# aps protection transparent 8/0/0
Node1(config-red-aps)# aps y-cable
Node1(config-red-aps)# aps enable
Node1(config-red-aps)# exit
Node1(config-red)# associate group channel2
Node1(config-red-aps)# aps working transparent 2/1/0
Node1(config-red-aps)# aps protection transparent 8/1/0
Node1(config-red-aps)# aps y-cable
Node1(config-red-aps)# aps enable
Node1(config-red-aps)# exit
Node1(config-red)# associate group channel3
Node1(config-red-aps)# aps working transparent 2/2/0
Node1(config-red-aps)# aps protection transparent 8/2/0
Node1(config-red-aps)# aps y-cable
Node1(config-red-aps)# aps enable
Node1(config-red-aps)# exit
Node1(config-red)# associate group channel4
Node1(config-red-aps)# aps working transparent 2/3/0
Node1(config-red-aps)# aps protection transparent 8/3/0
Node1(config-red-aps)# aps y-cable
Node1(config-red-aps)# aps enable
Node1(config-red-aps)# exit
Node1(config-red)# associate group channel5
Node1(config-red-aps)# aps working transparent 3/0/0
Node1(config-red-aps)# aps protection transparent 9/0/0
Node1(config-red-aps)# aps y-cable
Node1(config-red-aps)# aps enable
Node1(config-red-aps)# exit
Node1(config-red)# associate group channel6
Node1(config-red-aps)# aps working transparent 3/1/0
Node1(config-red-aps)# aps protection transparent 9/1/0
Node1(config-red-aps)# aps y-cable
Node1(config-red-aps)# aps enable
Node1(config-red-aps)# exit
Node1(config-red)# associate group channel7
Node1(config-red-aps)# aps working transparent 3/2/0
Node1(config-red-aps)# aps protection transparent 9/2/0
Node1(config-red-aps)# aps y-cable
Node1(config-red-aps)# aps enable
Node1(config-red-aps)# exit
Node1(config-red)# associate group channel8
Node1(config-red-aps)# aps working transparent 3/3/0
Node1(config-red-aps)# aps protection transparent 9/3/0
Node1(config-red-aps)# aps y-cable
Node1(config-red-aps)# aps enable
Node1(config-red-aps)# exit
Node1(config-red)# associate group channel9
Node1(config-red-aps)# aps working transparent 4/0/0
Node1(config-red-aps)# aps protection transparent 10/0/0
Node1(config-red-aps)# aps y-cable
Node1(config-red-aps)# aps enable
Node1(config-red-aps)# exit
Node1(config-red)# associate group channel10
Node1(config-red-aps)# aps working transparent 4/1/0
Node1(config-red-aps)# aps protection transparent 10/1/0
Node1(config-red-aps)# aps y-cable
Node1(config-red-aps)# aps enable
Node1(config-red-aps)# exit
Node1(config-red)# associate group channel11
Node1(config-red-aps)# aps working transparent 4/2/0
Node1(config-red-aps)# aps protection transparent 10/2/0
Node1(config-red-aps)# aps y-cable
Node1(config-red-aps)# aps enable
Node1(config-red-aps)# exit
Node1(config-red)# associate group channel12
Node1(config-red-aps)# aps working transparent 4/3/0
Node1(config-red-aps)# aps protection transparent 10/3/0
Node1(config-red-aps)# aps y-cable
Node1(config-red-aps)# aps enable
Node1(config-red-aps)# exit
Node1(config-red)# associate group channel13
Node1(config-red-aps)# aps working transparent 5/0/0
Node1(config-red-aps)# aps protection transparent 11/0/0
Node1(config-red-aps)# aps y-cable
Node1(config-red-aps)# aps enable
Node1(config-red-aps)# exit
Node1(config-red)# associate group channel14
Node1(config-red-aps)# aps working transparent 5/1/0
Node1(config-red-aps)# aps protection transparent 11/0/0
Node1(config-red-aps)# aps y-cable
Node1(config-red-aps)# aps enable
Node1(config-red-aps)# exit
Node1(config-red)# associate group channel15
Node1(config-red-aps)# aps working transparent 5/2/0
Node1(config-red-aps)# aps protection transparent 11/2/0
Node1(config-red-aps)# aps y-cable
Node1(config-red-aps)# aps enable
Node1(config-red-aps)# exit
Node1(config-red)# associate group channel16
Node1(config-red-aps)# aps working transparent 5/3/0
Node1(config-red-aps)# aps protection transparent 11/3/0
Node1(config-red-aps)# aps y-cable
Node1(config-red-aps)# aps enable
Node1(config-red-aps)# end

Node1# copy system:running-config nvram:startup-config

Repeat the entire preceding configuration on node 2.

Configuring an Unprotected Point-to-Point Topology

Figure 9-7 shows how the modules are installed in the shelf for a 32-channel point-to-point topology without protection.

Figure 9-7 Shelf Configuration for Unprotected 32-Channel Point-to-Point Topology

Figure 9-8 shows how the terminal mux/demux modules are cabled for the 32-channel unprotected point-to-point configuration.

Figure 9-8 Terminal Mux/Demux Module Cabling with OSC for Unprotected 32-Channel Point-to-Point Topology

Patch Connections

Node 1

Node1# configure terminal
Node1(config)# patch wave 0 oscfilter 0/0

Node1(config)# patch wavepatch 2/0/0 filter 0/0/0
Node1(config)# patch wavepatch 2/1/0 filter 0/0/1
Node1(config)# patch wavepatch 2/2/0 filter 0/0/2
Node1(config)# patch wavepatch 2/3/0 filter 0/0/3

Node1(config)# patch wavepatch 3/0/0 filter 0/0/4
Node1(config)# patch wavepatch 3/1/0 filter 0/0/5
Node1(config)# patch wavepatch 3/2/0 filter 0/0/6
Node1(config)# patch wavepatch 3/3/0 filter 0/0/7

Node1(config)# patch wavepatch 4/0/0 filter 0/0/8
Node1(config)# patch wavepatch 4/1/0 filter 0/0/9
Node1(config)# patch wavepatch 4/2/0 filter 0/0/10
Node1(config)# patch wavepatch 4/3/0 filter 0/0/11

Node1(config)# patch wavepatch 5/0/0 filter 0/0/12
Node1(config)# patch wavepatch 5/1/0 filter 0/0/13
Node1(config)# patch wavepatch 5/2/0 filter 0/0/14
Node1(config)# patch wavepatch 5/3/0 filter 0/0/15

Node1(config)# patch wavepatch 8/0/0 filter 0/0/16
Node1(config)# patch wavepatch 8/1/0 filter 0/0/17
Node1(config)# patch wavepatch 8/2/0 filter 0/0/18
Node1(config)# patch wavepatch 8/3/0 filter 0/0/19

Node1(config)# patch wavepatch 9/0/0 filter 0/0/20
Node1(config)# patch wavepatch 9/1/0 filter 0/0/20
Node1(config)# patch wavepatch 9/2/0 filter 0/0/22
Node1(config)# patch wavepatch 9/3/0 filter 0/0/23

Node1(config)# patch wavepatch 10/0/0 filter 0/0/24
Node1(config)# patch wavepatch 10/1/0 filter 0/0/25
Node1(config)# patch wavepatch 10/2/0 filter 0/0/26
Node1(config)# patch wavepatch 10/3/0 filter 0/0/27

Node1(config)# patch wavepatch 11/0/0 filter 0/0/28
Node1(config)# patch wavepatch 11/1/0 filter 0/0/29
Node1(config)# patch wavepatch 11/2/0 filter 0/0/30
Node1(config)# patch wavepatch 11/3/0 filter 0/0/31

Node 2

Node2# configure terminal
Node2(config)# patch wave 0 oscfilter 0/0

Node1(config)# patch wavepatch 2/0/0 filter 0/0/0
Node1(config)# patch wavepatch 2/1/0 filter 0/0/1
Node1(config)# patch wavepatch 2/2/0 filter 0/0/2
Node1(config)# patch wavepatch 2/3/0 filter 0/0/3

Node1(config)# patch wavepatch 3/0/0 filter 0/0/4
Node1(config)# patch wavepatch 3/1/0 filter 0/0/5
Node1(config)# patch wavepatch 3/2/0 filter 0/0/6
Node1(config)# patch wavepatch 3/3/0 filter 0/0/7

Node1(config)# patch wavepatch 4/0/0 filter 0/0/8
Node1(config)# patch wavepatch 4/1/0 filter 0/0/9
Node1(config)# patch wavepatch 4/2/0 filter 0/0/10
Node1(config)# patch wavepatch 4/3/0 filter 0/0/11

Node1(config)# patch wavepatch 5/0/0 filter 0/0/12
Node1(config)# patch wavepatch 5/1/0 filter 0/0/13
Node1(config)# patch wavepatch 5/2/0 filter 0/0/14
Node1(config)# patch wavepatch 5/3/0 filter 0/0/15

Node1(config)# patch wavepatch 8/0/0 filter 0/0/16
Node1(config)# patch wavepatch 8/1/0 filter 0/0/17
Node1(config)# patch wavepatch 8/2/0 filter 0/0/18
Node1(config)# patch wavepatch 8/3/0 filter 0/0/19

Node1(config)# patch wavepatch 9/0/0 filter 0/0/20
Node1(config)# patch wavepatch 9/1/0 filter 0/0/20
Node1(config)# patch wavepatch 9/2/0 filter 0/0/22
Node1(config)# patch wavepatch 9/3/0 filter 0/0/23

Node1(config)# patch wavepatch 10/0/0 filter 0/0/24
Node1(config)# patch wavepatch 10/1/0 filter 0/0/25
Node1(config)# patch wavepatch 10/2/0 filter 0/0/26
Node1(config)# patch wavepatch 10/3/0 filter 0/0/27

Node1(config)# patch wavepatch 11/0/0 filter 0/0/28
Node1(config)# patch wavepatch 11/1/0 filter 0/0/29
Node1(config)# patch wavepatch 11/2/0 filter 0/0/30
Node1(config)# patch wavepatch 11/3/0 filter 0/0/31

Transparent Interfaces

Node 1

Node1(config)# interface transparent 2/0/0
Node1(config-if)# encapsulation sonet oc12
Node1(config-if)# monitor enable
Node1(config-if)# exit

Configure the remaining transparent interfaces in the shelf the same as node 1 in the "Configuring a Point-to-Point Topology with Splitter Protection" section.


Node1# copy system:running-config nvram:startup-config

Node 2

Node2(config)# interface transparent 2/0/0
Node2(config-if)# encapsulation sonet oc12
Node2(config-if)# monitor enable
Node2(config-if)# end

Configure the remaining transparent interfaces in the shelf the same as node 1 in the "Configuring a Point-to-Point Topology with Splitter Protection" section.

Node2# copy system:running-config nvram:startup-config

hometocprevnextglossaryfeedbacksearchhelp

Posted: Thu Feb 16 04:04:35 PST 2006
All contents are Copyright © 1992--2006 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.