cc/td/doc/product/mels/15540
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table Of Contents

Specifications

Chassis Specifications

Channel to Wavelength Mapping

Mux/Demux Motherboard Specifications

4-Channel OADM Module Specifications

8-Channel OADM Module Specifications

16-Channel OADM Module Specifications

Line Card Motherboard Specifications

2.5-Gbps Transponder Module Specifications

Type 2 Extended Range Transponder Module Specifications

SFP Optics Specifications


Specifications


This appendix describes the specifications for the line card motherboards and transponder modules, and the mux/demux motherboards and modules used in the Cisco ONS 15540 ESP system. This appendix includes the following sections:

Chassis Specifications

Channel to Wavelength Mapping

Mux/Demux Motherboard Specifications

4-Channel OADM Module Specifications

8-Channel OADM Module Specifications

16-Channel OADM Module Specifications

Line Card Motherboard Specifications

2.5-Gbps Transponder Module Specifications

Type 2 Extended Range Transponder Module Specifications


Note Cisco recommends you to use the Cisco MetroPlanner tool to design your DWDM networks. For more information about optical power budgets and network planning, refer to the Cisco ONS 15540 ESP Planning Guide and the Cisco MetroPlanner DWDM Operations Guide.


Chassis Specifications

Table A-1 lists the specifications for the Cisco ONS 15540 ESP chassis.

Table A-1 Cisco ONS 15540 ESP Specifications 

Description
Specification
Environmental

Temperature, ambient operating

32 to 104°F (0° to +40°C)

Humidity (RH1 ), ambient (noncondensing) operating

90 to 95 percent

Physical Characteristics

Dimensions (H x W x D)

24.5 x 17.3 x 12 in.
(62.2 x 43.9 x 30.4 cm)

Weight

Chassis and Power Cord: 51 lbs (23.1 kg)
Chassis fully loaded:153 lbs (69.40 kg)

Optical ports

SC, MU, MT-RJ, LC, MPX

Fan assembly

2.5A at -48 VDC

Processor card

5.5 lbs (2.50 kg)
18 x 9 in. (45.7 x 22.9 cm)

AC-Input Power

AC-input voltage

100 to 240 VAC (nominal)
85 to 264 VAC (full range)

Current maximum

13.2A (100 VAC), 6.6A (200 VAC)

Power consumption maximum

1320W

Heat dissipation

4500 BTU/hr

DC-Input Power

DC-input voltage

-48 to -60 VDC (nominal)
-40.5 to -72 VDC (full range)

Power consumption maximum

1125W

Heat dissipation

3840 BTU/hr

1 RH = relative humidity


Channel to Wavelength Mapping

Table A-2 lists the channels, wavelengths, and frequencies for each band.

Table A-2 Channel to Wavelength Mapping 

Cisco ONS 15540 ESP
Band
Cisco ONS 15540 ESP Channel
ITU Channels
ITU Wavelength1
ITU Frequency2

OSC3

 

19

1562.23

191.900

A

1

21

1560.61

192.100

2

22

1559.79

192.200

3

23

1558.98

192.300

4

24

1558.17

192.400

B

5

26

1556.55

192.600

6

27

1555.75

192.700

7

28

1554.94

192.800

8

29

1554.13

192.900

C

9

31

1552.52

193.100

10

32

1551.72

193.200

11

33

1550.92

193.300

12

34

1550.12

193.400

D

13

36

1548.51

193.600

14

37

1547.72

193.700

15

38

1546.92

193.800

16

39

1546.12

193.900

E

17

41

1544.53

194.100

18

42

1543.73

194.200

19

43

1542.94

194.300

20

44

1542.14

194.400

F

21

46

1540.56

194.600

22

47

1539.77

194.700

23

48

1538.98

194.800

24

49

1538.19

194.900

G

25

51

1536.61

195.100

26

52

1535.82

195.200

27

53

1535.04

195.300

28

54

1534.25

195.400

H

29

56

1532.68

195.600

30

57

1531.90

195.700

31

58

1531.12

195.800

32

59

1530.33

195.900

1 Wavelengths in vacuum in nm

2 Frequency in THz, 100 GHz grid

3 OSC = optical supervisory channel


Mux/Demux Motherboard Specifications

Table A-3 lists the specifications for the mux/demux motherboard.

Table A-3 Mux/Demux Motherboard Specifications  

Description
Specification

Fiber type

SM1 9 micron

Connector

MU

Output wavelength

1562.23 nm, ITU channel

Dimensions

3.7 x 9 in. (9.4 x 22.9 cm)

Weight

3.5 lbs (1.59 kg)

Receiver
Minimum
Maximum

Receive sensitivity

-19 dBm

 

Receive overload

 

-1.5 dBm

Input wavelength

1530.33 nm

1562.23 nm

Optical reflectance

-27 dB

 

Side mode suppression

30 dB

 

Transmitter
Minimum
Maximum

Transmitter power

4 dBm

8 dBm

Output wavelength

1530.33 nm

1560.61 nm

Dispersion tolerance

 

1800 ps/nm2 3

1 SM = single mode

2 ps/nm = picoseconds per nanometer

3 1800 ps/nm at OC-48 rate


4-Channel OADM Module Specifications

Table A-4 lists the specifications for the 4-channel and 4-channel with OSC OADM module.

Table A-4 4-Channel and 4-Channel with OSC Mux/Demux Modules 

Description
Specification

Dimensions

1.0 x 3.3 x 7.7 in. (+1.5 in. for handle)
(2.5 x 8.4 x 19.6 cm [+3.8 cm for handle])

Weight

0.5 lbs (.23 kg)

Fiber

ITU-T G.652 compliant

OSC1

1562.23 nm

Connector

MU

Operating temperature

32 to 104°F (0 to 40°C)

Storage temperature

-40 to 85°F (-40 to 29.4°C)

Channel mapping

Bands A to H2

Maximum relative humidity

90 to 95%

1 OSC = optical supervisory channel.

2 See Table A-2 for band A to H wavelengths.


8-Channel OADM Module Specifications

Table A-5 lists the specifications for the 8-channel and 8-channel with OSC OADM module.

Table A-5 8-Channel and 8-Channel with OSC OADM Modules 

Description
Specification

Dimensions

1.0 x 3.3 x 7.7 in. (+1.5 in. for handle)
(2.5 x 8.4 x 19.6 cm [+3.8 cm for handle])

Weight

1.0 lbs (0.45 kg)

Fiber

ITU-T G.652 compliant

OSC1

1562.23 nm

Connector

MU

Operating temperature

32 to 104°F (0 to 40°C)

Storage temperature

-40 to 85°F (-40 to 29.4°C)

Channel mapping

Channels AB, CD, EF, and GH2

Maximum relative humidity

90 to 95%

1 OSC = optical supervisory channel.

2 See Table A-2 for band A to H wavelengths.


16-Channel OADM Module Specifications

Table A-6 lists the specifications for the 16-channel OADM module.

Table A-6 16-Channel OADM Modules 

Description
Specification

Dimensions

1.0 x 6.6 x 7.7 in. (+1.5 in.for handle)
(2.5 x 2.0 x 19.6 cm [+3.8 cm for handle])

Weight

1.5 lbs (0.68 kg)

Fiber

ITU-T G.652 compliant

OSC1

1562.23 nm

Connectors

MU

Operating temperature

0 to 65°C

Storage temperature

-40 to 85 °C

Wavelengths

32, ITU G.692

1 OSC = optical supervisory channel


Line Card Motherboard Specifications

Table A-7 lists the specifications for the 2.5-Gbps line card motherboard.

Table A-7 2.5-Gbps Line Card Motherboard Specifications

Description
Specification

Dimensions

18 x 9 in. (45.72 x 22.86 cm)


Table A-8 lists the specifications for the 10-Gbps line card motherboard.

Table A-8 10-Gbps Line Card Motherboard Specifications

Description
Specification

Dimensions

1.3 x 9.1 x 18.1 in. (3.3 x 23.11 x 45.97 cm)


2.5-Gbps Transponder Module Specifications

Table A-9 lists the client side optical specifications for the 2.5-Gbps transponder module.

Table A-9 2.5-Gbps SM and MM Transponder Client Side Specifications 

Description
Specification

Dimensions

3 x 7.5 in. (7.6 x 19.1 cm)

Weight

 

Connector

SC

Trunk connector

MUJ

Receiver
Single Mode
Multimode
Minimum
Maximum
Minimum
Maximum

Bit rate

16 Mbps

2.5 Gbps

16 Mbps

622 Mbps

Receive sensitivity

 -19 dBm

 

-25 dBm

 

Receive overload

 

-1.5 dBm

 

-8 dBm

Input wavelength

1249 nm

1600 nm

1249 nm

1600 nm

Transmitter power

-5 dBm

0 dBm

-5 dBm

0 dBm

Output wavelength

1260 nm

1360 nm

1260 nm

1360 nm


Table A-10 lists the trunk side optical specifications for the 2.5-Gbps transponder module.

Table A-10 2.5-Gbps Trunk Side Optical Specifications 

Description
Specification

Fiber type

ITU-T G.652 compliant

Connector

MUJ

Receiver
Minimum
Maximum

OSNR 1 , 2

19 dB

 

Receive sensitivity 2

-28 dBm

 

Receive overload

 

-8 dBm

Input wavelength

1260 nm

1580 nm

Transmitter
Minimum
Maximum

Transmitter power

4 dBm

8 dBm

Dispersion tolerance

 

1800 ps/nm3

1 OSNR = optical signal-to-noise ratio.

2 Add the proper network-level penalty to the OSNR and/or receive power based on your actual network topology characteristics, such as dispersion.

3 ps/nm = picoseconds per nanometer.


 

Type 2 Extended Range Transponder Module Specifications

Table A-11 lists the specifications for the Type 2 extended range transponder modules.

Table A-11 Type 2 Extended Range Transponder Module Specifications  

Description
Specification

Fiber

ITU-T G.652 compliant

Receiver Specifications
Minimum
Maximum

OSNR1

19 db

 

Receive sensitivity 1

-28 dBm

 

Receive overload

 

-8 dBm

Input wavelength

1430 nm

1580 nm

Transmitter Specification
Minimum
Maximum

Output power

5 dBm

10 dBm

Dispersion tolerance

 

3200 ps/nm

1 Add the proper network level penalty to the OSNR and/or receive power based on your actual network topology characteristics, such as dispersion.


SFP Optics Specifications

Table A-12 lists the specifications for the Cisco ONS 15540 ESP fixed rate SFP optics.


Note Only use Cisco-certified SFP optics for the Type 2 extended range transponders.


Table A-12 Fixed Rate SFP Optics Specifications 

Description
Specification
Part number
15500-XVRA-01A2

ESCON, OC-3/STM-1 MM

Dimensions (H x W x D)

0.486 x 0.522 x 2.24 in. (1.23 x 1325.9 x 5.69 cm)

Data rate

155 Mbps, 200 Mbps

Wavelength

1310 nm

Fiber type

MM, 50/125 µm, 62.5/125 µm

Connector type

MT-RJ

Receiver
Minimum
Maximum

Receive sensitivity

-33 dBm

-14 dBm

Input wavelength

1280 nm

1380 nm

Transmitter
Minimum
Maximum

Transmitter power

-19.5 dBm

-15 dBm

Output wavelength

1280 nm

1380 nm

Part number
15500-XVRA-02C1

Gigabit Ethernet, Fibre Channel (1 Gbps), and FICON (1-Gbps) MM

Dimensions

0.486 x 0.522 x 2.24 in. (1.23 x 1325.9 x 5.69 cm)

Data rate

1.0625 Gbps, 1.25 Gbps

Wavelength

850 nm

 

Fiber type

MM, 50/125 µm, 62.5/125 µm

Connector type

LC

Receiver
Minimum
Maximum

Receive sensitivity

-18 dBm

 

Stressed receive sensitivity

-13.5 dBm

 

Input wavelength

770 nm

860 nm

Transmitter
Minimum
Maximum

Transmitter power

-9.5 dBm

-4 dBm

Output wavelength

830 nm

860 nm

Part number
15500-XVRA-03B1

Gigabit Ethernet, Fibre Channel (1 Gbps), and FICON (1Gbps) SM

Dimensions

0.486 x 0.522 x 2.24 in. (1.23 x 1325.9 x 5.69 cm)

Data rate

1.0625 Gbps, 1.25 Gbps

Wavelength

1310 nm

Fiber type

SM, 9/125 µm

Connector type

LC

Receiver
Minimum
Maximum

Input power

-20.5 dBm

-3 dBm

Input wavelength

1270 nm

1600 nm

Transmitter
Minimum
Maximum

Transmitter power

-9.5 dBm

-3 dBm

Output wavelength

1275 nm

1350 nm

Part number
15500-XVRA-03B2

Fibre Channel (1 Gbps and 2 Gbps) and FICON (1 Gbps and 2 Gbps) SM

Dimensions

0.486 x 0.522 x 2.24 in. (1.23 x 1325.9 x 5.69 cm)

Data rate

1.0625 Gbps, 2.125 Gbps

Wavelength

1310 nm

Fiber type

SM, 9/125 µm

Connector type

LC

Receiver
Minimum
Maximum

Receive sensitivity

-20.5 dBm

 

Input wavelength

1270 nm

1600 nm

Transmitter
Minimum
Maximum

Transmitter power

-9.5 dBm

-3 dBm

Output wavelength

1275 nm

1350 nm

Part number
15500-XVRA-02C2

Fibre Channel (1 Gbps and 2 Gbps) and FICON (1 Gbps and 2 Gbps) MM

Dimensions

0.486 x 0.522 x 2.24 in. (1.23 x 1325.9 x 5.69 cm)

Data rate

2.125 Gbps

Wavelength

850 nm

Fiber type

MM, 50/125 µm, 62.5/125 µm

Connector type

LC

Receiver
Minimum
Maximum

Receive sensitivity <= 1.06 Gbps)

-18 dBm

 

Receive sensitivity (> 1.06 Gbps)

-15 dBm

 

Stressed receive sensitivity (<= 1.06 Gbps)

-13.5 dBm

 

Stressed receive sensitivity (> 1.06 Gbps)

-12.1 dBm

-12.1 dBm

Input wavelength

770 nm

860 nm

Transmitter
Minimum
Maximum

Transmitter power

-9 dBm

-4 dBm

Output wavelength

830 nm

860 nm

Part number
15500-XVRA-06B1

OC-12/STM-4 SM

Dimensions

0.486 x 0.522 x 2.24 in. (1.23 x 1325.9 x 5.69 cm)

Data rate

622 Mbps

Wavelength

1310 nm

Fiber type

SM, 9/125 µm

Connector type

LC

Receiver
Minimum
Maximum

Receive sensitivity

-28 dBm

 

Receive overload

 

-7 dBm

Input wavelength

1100 nm

1600 nm

Transmitter
Minimum
Maximum

Transmitter power

-15 dBm

-8 dBm

Output wavelength

1260 nm

1360 nm

Part number
15500-XVRA-07B1

OC-48/STM-16 SM

Dimensions

0.486 x 0.522 x 2.24 in. (1.23 x 1325.9 x 5.69 cm)

Data rate

2.488 Mbps

Wavelength

1310 nm

Fiber type

SM, 9/125 µm

Connector type

LC

Receiver
Minimum
Maximum

Receive sensitivity

-18 dBm

 

Receive overload

 

-3 dBm

Input wavelength

1270 nm

1600 nm

Transmitter
Minimum
Maximum

Transmitter power

-9.5 dBm

-3 dBm

Output wavelength

1285 nm

1340 nm


Table A-13 lists the specifications for the Cisco ONS 15540 ESP variable rate SFP optics.


Note Only use Cisco-certified SFP optics for the Type 2 extended range transponders.


Table A-13 Variable Rate SFP Optics Specifications 

Description
Specification
Part number
15500-XVRA-10A1

Supported protocol encapsulations

Sysplex, Fast Ethernet, OC-3/STM-1, ESCON (MM)

Dimensions

0.486 x 0.522 x 2.24 in. (1.23 x 1325.9 x 5.69 cm)

Data rate

8 to 200 Mbps

Wavelength

1310 nm

Fiber type

MM 50/125 µm
MM 62.5/125 µm

Connector type

LC

Receiver
Minimum
Maximum

Receive sensitivity @10-12 BER1

-32 dBm

 

Receive sensitivity @10-15 BER

-29 dBm

 

Receive overload @10-12  BER

 

-14 dBm

Input wavelength

1100 nm

1600 nm

Transmitter
Minimum
Maximum

Transmitter power

-19 dBm

-14 dBm

Output wavelength

1280 nm

1380 nm

Part number
15500-XVRA-10B1

Supported protocol encapsulations

Sysplex, Fast Ethernet, OC-3/STM-1, ESCON (SM)

Dimensions

0.486 x 0.522 x 2.24 in. (1.23 x 1325.9 x 5.69 cm)

Data rate range

8 Mbps to 200 Mbps

Wavelength

1310 nm

Fiber type

SM, 9/125 µm

Connector type

LC

Receiver
Minimum
Maximum

Receive sensitivity @10-12 BER

-32 dBm

 

Receive overload @10-12  BER

 

-3 dBm

Input wavelength

1100 nm

1600 nm

Transmitter
Minimum
Maximum

Transmitter power

-8 dBm

-4 dBm

Output wavelength

1260 nm

1360 nm

Part number
15500-XVRA-11A1

Supported protocol encapsulations

ESCON, OC-12/STM-4

Dimensions

0.486 x 0.522 x 2.24 in. (1.23 x 1325.9 x 5.69 cm)

Data rate range

200 Mbps to 622 Mbps

Wavelength

1310 nm

Fiber type

MM 62.5/125 µm

Connector type

LC

Receiver
Minimum
Maximum

Receive sensitivity @10-10 BER

-26 dBm

 

Receive sensitivity @10-12 BER

-25 dBm

 

Maximum receive power @10-10  BER

 

-14

Input wavelength

1100 nm

1600 nm

Transmitter
Minimum
Maximum

Transmitter power

-20 dBm

-14 dBm

Output wavelength

1270 nm

1380 nm

Part number
15500-XVRA-11B1

Supported protocol encapsulations

ESCON, SONET OC-12, SDH STM-4, FC, GE

Dimensions

0.486 x 0.522 x 2.24 in. (1.23 x 1325.9 x 5.69 cm)

Data rate range

200 Mbps to 1.25 Gbps

Wavelength

1310 nm

Fiber type

SM, 9/125 µm

Connector type

LC

Receiver
Minimum
Maximum

Receive sensitivity @10-12 BER

-20 dBm

 

Maximum receive power @10-12 BER

 

-3 dBm

Input wavelength

1100 nm

1600 nm

Transmitter
Minimum
Maximum

Transmitter power

-9 dBm

-3 dBm

Output wavelength

1285 nm

1345 nm

Part number
15500-XVRA-12B1

Supported protocol encapsulations

Fibre Channel, FICON, GE, OC-48/STM-16

Dimensions

0.486 x 0.522 x 2.24 in (1.23 x 1325.9 x 5.69 cm)

Data rate range

1.062 Mbps to 2.488 Gbps

Wavelength

1310 nm

Fiber type

SM, 9/125 µm

Connector type

LC

Receiver
Minimum
Maximum

Receive sensitivity @10-10 BER

-18 dBm

 

Maximum receive power @10-10  BER

 

-3 dBm

Input wavelength

1100 nm

1600 nm

Transmitter
Minimum
Maximum

Transmitter power

-10 dBm

-3 dBm

Output wavelength

1266 nm

1360 nm

1 BER = bit error rate



hometocprevnextglossaryfeedbacksearchhelp

Posted: Wed Jul 5 18:20:13 PDT 2006
All contents are Copyright © 1992--2006 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.