Table Of Contents
Release Notes for Cisco ONS 15530
for Cisco IOS Release 12.2(29)SV1Determining the Software Version
New Features in Release 12.2(29)SV1
New Features in Release 12.2(29)SV
New Features in Release 12.2(26)SV1
New Features in Release 12.2(26)SV
New Features in Release 12.2(25)SV
New Features in Release 12.2(24)SV
New Features in Release 12.2(23)SV
New Features in Release 12.2(22)SV
New Features in Release 12.2(18)SV2
New Features in Release 12.2(18)SV1
New Features in Release 12.2(18)SV
Open Caveats in Release 12.2(29)SV1
Resolved Caveats in Release 12.2(29)SV1
Resolved Caveats in Release 12.2(29)SV
Resolved Caveats in Release 12.2(26)SV1
Resolved Caveats in Release 12.2(26)SV
Resolved Caveats in Release 12.2(25)SV
Resolved Caveats in Release 12.2(24)SV
Resolved Caveats in Release 12.2(23)SV
Resolved Caveats in Release 12.2(22)SV
Resolved Caveats in Release 12.2(18)SV2
Resolved Caveats in Release 12.2(18)SV1
Resolved Caveats in Release 12.2(18)SV
Where to Find Safety and Warning Information
Cisco Optical Networking Product Documentation CD-ROM
Cisco Product Security Overview
Reporting Security Problems in Cisco Products
Obtaining Technical Assistance
Cisco Technical Support & Documentation Website
Definitions of Service Request Severity
Obtaining Additional Publications and Information
Release Notes for Cisco ONS 15530
for Cisco IOS Release 12.2(29)SV1
This document describes caveats for Cisco IOS Release 12.2(29)SV1 for the Cisco ONS 15530.
Date: May 15, 2006
Text Part Number: OL-10407-01
Contents
This document includes the following information:
• Caveats
• Limitations and Restrictions
• Where to Find Safety and Warning Information
• Cisco Product Security Overview
• Obtaining Technical Assistance
• Obtaining Additional Publications and Information
Introduction
The Cisco ONS 15530 is a DWDM multiservice aggregation platform that maximizes the carrying capacity of fiber by performing service aggregation of protocols such as ESCON, Fibre Channel, FICON, and Gigabit Ethernet. With the Cisco ONS 15530, users can take advantage of the availability of dark fiber to build a common infrastructure that supports data, SAN (storage area networking), and TDM (time-division multiplexing) traffic. For more information about DWDM technology and applications, refer to the Introduction to DWDM Technology publication and the Cisco ONS 15530 Planning Guide.
System Requirements
This section describes the system requirements for the Cisco ONS 15530 and includes the following sections:
• Determining the Software Version
Memory Requirements
The DRAM memory configuration is 64 MB, which is the default for the Cisco ONS 15530.
Hardware Supported
Table 1 lists the hardware components supported on the Cisco ONS 15530 and the minimum software version required. See the "Determining the Software Version" section.
Table 1 Cisco ONS 15530 Supported Hardware and Minimum Software Requirements
Component Part Number Description Minimum Software Version Required1Chassis
15530-CHAS-N
15530-CHAS-N chassis, NEBS version
12.1(10)EV1
15530-CHAS-E
15530-CHAS-E chassis, ETSI version
12.1(10)EV1
Power supplies
15530-PWR-AC
120 to 240 VAC power supply
12.1(10)EV1
15530-PWR-DC
Power supply -48 VDC
12.1(10)EV1
CPU switch module
15530-CPU
ONS 15530 CPU switch module
12.1(10)EV1
Carrier motherboard
15530-LCMB-0100
Carrier motherboard (supports OSC, WB-VOA, and PB-OE modules)
12.1(10)EV1
OADM modules without OSC
15530-MDXA-04A0
4-channel Band A
12.1(10)EV1
15530-MDXA-04B0
4-channel Band B
12.1(10)EV1
15530-MDXA-04C0
4-channel Band C
12.1(10)EV1
15530-MDXA-04D0
4-channel Band D
12.1(10)EV1
15530-MDXA-04E0
4-channel Band E
12.1(10)EV1
15530-MDXA-04F0
4-channel Band F
12.1(10)EV1
15530-MDXA-04G0
4-channel Band G
12.1(10)EV1
15530-MDXA-04H0
4-channel Band H
12.1(10)EV1
OADM modules with OSC
15530-MDXB-04A0
4-channel Band A
12.1(10)EV1
15530-MDXB-04B0
4-channel Band B
12.1(10)EV1
15530-MDXB-04C0
4-channel Band C
12.1(10)EV1
15530-MDXB-04D0
4-channel Band D
12.1(10)EV1
15530-MDXB-04E0
4-channel Band E
12.1(10)EV1
15530-MDXB-04F0
4-channel Band F
12.1(10)EV1
15530-MDXB-04G0
4-channel Band G
12.1(10)EV1
15530-MDXB-04H0
4-channel Band H
12.1(10)EV1
MM transponder line cards with splitter
15530-TSP1-0111
Ch 1-2—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-0311
Ch 3-4—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-0511
Ch 5-6—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-0711
Ch 7-8—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-0911
Ch 9-10—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-1111
Ch 11-12—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-1311
Ch 13-14—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-1511
Ch 15-16—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-1711
Ch 17-18—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-1911
Ch 19-20—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-2111
Ch 21-22—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-2311
Ch 23- 24—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-2511
Ch 25-26—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-2711
Ch 27-28—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-2911
Ch 29-30—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-3111
Ch 31-32—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
MM transponder line cards without splitter
15530-TSP1-0121
Ch 1-2—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-0321
Ch 3-4—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-0521
Ch 5-6—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-0721
Ch 7-8—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-0921
Ch 9-10—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-1121
Ch 11-12—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-1321
Ch 13-14—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-1521
Ch 15-16—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-1721
Ch 17-18—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-1921
Ch 19-20—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-2121
Ch 21-22—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-2321
Ch 23- 24—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-2521
Ch 25-26—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-2721
Ch 27-28—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-2921
Ch 29-30—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-3121
Ch 31-32—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
SM transponder line cards with splitter
15530-TSP1-0112
Ch 1-2—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-0312
Ch 3-4—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-0512
Ch 5-6—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-0712
Ch 7-8—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-0912
Ch 9-10—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-1112
Ch 11-12—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-1312
Ch 13-14— 1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-1512
Ch 15-16—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-1712
Ch 17-18—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-1912
Ch 19-20—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-2112
Ch 21-22—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-2312
Ch 23- 24—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-2512
Ch 23- 24—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-2712
Ch 25-26—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-2912
Ch 27-28—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-3112
Ch 29-30 —1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
SM transponder line cards without splitter
15530-TSP1-0122
Ch 1-2—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-0322
Ch 3-4—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-0522
Ch 5-6—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-0722
Ch 7-8—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-0922
Ch 9-10—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-1122
Ch 11-12—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-1322
Ch 13-14—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-1522
Ch 15-16—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-1722
Ch 17-18—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-1922
Ch 19-20—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-2122
Ch 21-22—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-2322
Ch 23- 24—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-2522
Ch 23- 24—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-2722
Ch 25-26—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-2922
Ch 27-28—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-3122
Ch 29-30 —1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
Aggregation cards
15530-LCMB-0200
ONS 15530 10-port ESCON aggregation card
12.1(10)EV1
15530-FCGE-8P
ONS 15530 8-port Fibre Channel/Gigabit Ethernet aggregation card
12.1(12c)EV
15530-FC-4P
ONS 15530 4-port 1-Gbps/2-Gbps FC aggregation card
12.2(23)SV
Muxponders
15530-MSMP-0112
Multi service muxponder splitter ch 1/2
12.2(25)SV
15530-MSMP-0122
Multi service muxponder nsplitter ch 1/2
12.2(25)SV
15530-MSMP-0312
Multi service muxponder splitter ch 3/4
12.2(25)SV
15530-MSMP-0322
Multi service muxponder nsplitter ch 3/4
12.2(25)SV
15530-MSMP-0512
Multi service muxponder splitter ch 5/6
12.2(25)SV
15530-MSMP-0522
Multi service muxponder nsplitter ch 5/6
12.2(25)SV
15530-MSMP-0712
Multi service muxponder splitter ch 7/8
12.2(25)SV
15530-MSMP-0722
Multi service muxponder nsplitter ch 7/8
12.2(25)SV
15530-MSMP-0912
Multi service muxponder splitter ch 9/10
12.2(25)SV
15530-MSMP-0922
Multi service muxponder nsplitter ch 9/10
12.2(25)SV
15530-MSMP-1112
Multi service muxponder splitter ch 11/12
12.2(25)SV
15530-MSMP-1122
Multi service muxponder nsplitter ch 11/12
12.2(25)SV
15530-MSMP-1312
Multi service muxponder splitter ch 13/14
12.2(25)SV
15530-MSMP-1322
Multi service muxponder nsplitter ch 13/14
12.2(25)SV
15530-MSMP-1512
Multi service muxponder splitter ch 15/16
12.2(25)SV
15530-MSMP-1522
Multi service muxponder nsplitter ch 15/16
12.2(25)SV
15530-MSMP-1712
Multi service muxponder splitter ch 17/18
12.2(25)SV
15530-MSMP-1722
Multi service muxponder nsplitter ch 17/18
12.2(25)SV
15530-MSMP-1912
Multi service muxponder splitter ch 19/20
12.2(25)SV
15530-MSMP-1922
Multi service muxponder nsplitter ch 19/20
12.2(25)SV
15530-MSMP-2112
Multi service muxponder splitter ch 21/22
12.2(25)SV
15530-MSMP-2122
Multi service muxponder nsplitter ch 21/22
12.2(25)SV
15530-MSMP-2312
Multi service muxponder splitter ch 23/24
12.2(25)SV
15530-MSMP-2322
Multi service muxponder nsplitter ch 23/24
12.2(25)SV
15530-MSMP-2512
Multi service muxponder splitter ch 25/26
12.2(25)SV
15530-MSMP-2522
Multi service muxponder nsplitter ch 25/26
12.2(25)SV
15530-MSMP-2712
Multi service muxponder splitter ch 27/28
12.2(25)SV
15530-MSMP-2722
Multi service muxponder nsplitter ch 27/28
12.2(25)SV
15530-MSMP-2912
Multi service muxponder splitter ch 29/30
12.2(25)SV
15530-MSMP-2922
Multi service muxponder nsplitter ch 29/30
12.2(25)SV
15530-MSMP-3112
Multi service muxponder splitter ch 31/32
12.2(25)SV
15530-MSMP-3122
Multi service muxponder nsplitter ch 31/32
12.2(25)SV
2.5-Gbps ITU trunk cards
15530-ITU3-0110
ONS 15530 Ch 1/2 2.5-Gbps ITU trunk card MU with splitter
12.1(12c)EV
15530-ITU3-0310
ONS 15530 Ch 3/4 2.5-Gbps ITU trunk card MU with splitter
12.1(12c)EV
15530-ITU3-0510
ONS 15530 Ch 5/6 2.5-Gbps ITU trunk card MU with splitter
12.1(12c)EV
15530-ITU3-0710
ONS 15530 Ch 7/8 2.5-Gbps ITU trunk card MU with splitter
12.1(12c)EV
15530-ITU3-0910
ONS 15530 Ch 9/10 2.5-Gbps ITU trunk card MU with splitter
12.1(12c)EV
15530-ITU3-1110
ONS 15530 Ch 11/12 2.5-Gbps ITU trunk card MU with splitter
12.1(12c)EV
15530-ITU3-1310
ONS 15530 Ch 13/14 2.5-Gbps ITU trunk card MU with splitter
12.1(12c)EV
15530-ITU3-1510
ONS 15530 Ch 15/16 2.5-Gbps ITU trunk card MU with splitter
12.1(12c)EV
15530-ITU3-1710
ONS 15530 Ch 17/18 2.5-Gbps ITU trunk card MU with splitter
12.1(12c)EV
15530-ITU3-1910
ONS 15530 Ch 19/20 2.5-Gbps ITU trunk card MU with splitter
12.1(12c)EV
15530-ITU3-2110
ONS 15530 Ch 21/22 2.5-Gbps ITU trunk card MU with splitter
12.1(12c)EV
15530-ITU3-2310
ONS 15530 Ch 23/24 2.5-Gbps ITU trunk card MU with splitter
12.1(12c)EV
15530-ITU3-2510
ONS 15530 Ch 25/26 2.5-Gbps ITU trunk card MU with splitter
12.1(12c)EV
15530-ITU3-2710
ONS 15530 Ch 27/28 2.5-Gbps ITU trunk card MU with splitter
12.1(12c)EV
15530-ITU3-2910
ONS 15530 Ch 29/30 2.5-Gbps ITU trunk card MU with splitter
12.1(12c)EV
15530-ITU3-3110
ONS 15530 Ch 31/32 2.5-Gbps ITU trunk card MU with splitter
12.1(12c)EV
15530-ITU3-0120
ONS 15530 Ch 1/2 2.5-Gbps ITU trunk card MU without splitter
12.1(12c)EV
15530-ITU3-0320
ONS 15530 Ch 3/4 2.5-Gbps ITU trunk card MU without splitter
12.1(12c)EV
15530-ITU3-0520
ONS 15530 Ch 5/6 2.5-Gbps ITU trunk card MU without splitter
12.1(12c)EV
15530-ITU3-0720
ONS 15530 Ch 7/8 2.5-Gbps ITU trunk card MU without splitter
12.1(12c)EV
15530-ITU3-0920
ONS 15530 Ch 9/10 2.5-Gbps ITU trunk card MU without splitter
12.1(12c)EV
15530-ITU3-1120
ONS 15530 Ch 11/12 2.5-Gbps ITU trunk card MU without splitter
12.1(12c)EV
15530-ITU3-1320
ONS 15530 Ch 13/14 2.5-Gbps ITU trunk card MU without splitter
12.1(12c)EV
15530-ITU3-1520
ONS 15530 Ch 15/16 2.5-Gbps ITU trunk card MU without splitter
12.1(12c)EV
15530-ITU3-1720
ONS 15530 Ch 17/18 2.5-Gbps ITU trunk card MU without splitter
12.1(12c)EV
15530-ITU3-1920
ONS 15530 Ch 19/20 2.5-Gbps ITU trunk card MU without splitter
12.1(12c)EV
15530-ITU3-2120
ONS 15530 Ch 21/22 2.5-Gbps ITU trunk card MU without splitter
12.1(12c)EV
15530-ITU3-2320
ONS 15530 Ch 23/24 2.5-Gbps ITU trunk card MU without splitter
12.1(12c)EV
15530-ITU3-2520
ONS 15530 Ch 25/26 2.5-Gbps ITU trunk card MU without splitter
12.1(12c)EV
15530-ITU3-2720
ONS 15530 Ch 27/28 2.5-Gbps ITU trunk card MU without splitter
12.1(12c)EV
15530-ITU3-2920
ONS 15530 Ch 29/30 2.5-Gbps ITU trunk card MU without splitter
12.1(12c)EV
15530-ITU3-3120
ONS 15530 Ch 31/32 2.5-Gbps ITU trunk card MU without splitter
12.1(12c)EV
10-Gbps ITU trunk cards with splitter (1550 nm)
15530-ITU2-0110
CH 1—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-0210
CH 2—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-0310
CH 3—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-0410
CH 4—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-0510
CH 5—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-0610
CH 6—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-0710
CH 7—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-0810
CH 8—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-0910
CH 9—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-1010
CH 10—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-1110
CH 11—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-1210
CH 12—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-1310
CH 13—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-1410
CH 14—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-1510
CH 15—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-1610
CH 16—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-1710
CH 17—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-1810
CH 18—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-1910
CH 19—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-2010
CH 20—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-2110
CH 21—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-2210
CH 22—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-2310
CH 23—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-2410
CH 24—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-2510
CH 25—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-2610
CH 26—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-2710
CH 27—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-2810
CH 28—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-2910
CH 29—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-3010
CH 30—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-3110
CH 31—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-3210
CH 32—10-Gbps ITU trunk card with splitter
12.1(10)EV1
10-Gbps ITU trunk cards without splitter
(1550 nm)15530-ITU2-0120
CH 1—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-0220
CH 2—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-0320
CH 3—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-0420
CH 4—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-0520
CH 5—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-0620
CH 6—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-0720
CH 7—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-0820
CH 8—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-0920
CH 9—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-1020
CH 10—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-1120
CH 11—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-1220
CH 12—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-1320
CH 13—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-1420
CH 14—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-1520
CH 15—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-1620
CH 16—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-1720
CH 17—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-1820
CH 18—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-1920
CH 19—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-2020
CH 20—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-2120
CH 21—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-2220
CH 22—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-2320
CH 23—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-2420
CH 24—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-2520
CH 25—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-2620
CH 26—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-2720
CH 27—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-2820
CH 28—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-2920
CH 29—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-3020
CH 30—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-3120
CH 31—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-3220
CH 32—10-Gbps ITU trunk card without splitter
12.1(10)EV1
10-Gbps ITU tunable trunk cards with splitter (1550 nm)
15530-10G-4CHA10
Band A—10-Gbps ITU tunable trunk card with splitter
12.2(26)SV
15530-10G-4CHB10
Band B—10-Gbps ITU tunable trunk card with splitter
12.2(26)SV
15530-10G-4CHC10
Band C—10-Gbps ITU tunable trunk card with splitter
12.2(26)SV
15530-10G-4CHD10
Band D—10-Gbps ITU tunable trunk card with splitter
12.2(26)SV
15530-10G-4CHE10
Band E—10-Gbps ITU tunable trunk card with splitter
12.2(26)SV
15530-10G-4CHF10
Band F—10-Gbps ITU tunable trunk card with splitter
12.2(26)SV
15530-10G-4CHG10
Band G—10-Gbps ITU tunable trunk card with splitter
12.2(26)SV
15530-10G-4CHH10
Band H—10-Gbps ITU tunable trunk card with splitter
12.2(26)SV
10-Gbps ITU tunable trunk cards without splitter (1550 nm)
15530-10G-4CHA20
Band A—10-Gbps ITU tunable trunk card without splitter
12.2(26)SV
15530-10G-4CHB20
Band B—10-Gbps ITU tunable trunk card without splitter
12.2(26)SV
15530-10G-4CHC20
Band C—10-Gbps ITU tunable trunk card without splitter
12.2(26)SV
15530-10G-4CHD20
Band D—10-Gbps ITU tunable trunk card without splitter
12.2(26)SV
15530-10G-4CHE20
Band E—10-Gbps ITU tunable trunk card without splitter
12.2(26)SV
15530-10G-4CHF20
Band F—10-Gbps ITU tunable trunk card without splitter
12.2(26)SV
15530-10G-4CHG20
Band G—10-Gbps ITU tunable trunk card without splitter
12.2(26)SV
15530-10G-4CHH20
Band H—10-Gbps ITU tunable trunk card without splitter
12.2(26)SV
10-GE uplink card
15530-10GE-UPLINK
ONS 15530 10-Gbps uplink, 1310nm with SC
12.1(10)EV1
WB-VOA module
15500-VOA-0100
Single wide-band variable optical attenuator
12.1(10)EV1
15500-VOA-0200
Dual wide-band variable optical attenuator
12.1(10)EV1
Single-band PB-OE module
15500-PEQ-01A0
Single-band optical equalizer Band A
12.1(10)EV1
15500-PEQ-01B0
Single-band optical equalizer Band B
12.1(10)EV1
15500-PEQ-01C0
Single-band optical equalizer Band C
12.1(10)EV1
15500-PEQ-01D0
Single-band optical equalizer Band D
12.1(10)EV1
15500-PEQ-01E0
Single-band optical equalizer Band E
12.1(10)EV1
15500-PEQ-01F0
Single-band optical equalizer Band F
12.1(10)EV1
15500-PEQ-01G0
Single-band optical equalizer Band G
12.1(10)EV1
15500-PEQ-01H0
Single-band optical equalizer Band H
12.1(10)EV1
Dual-band PB-OE module
15500-PEQ-02AB
Dual band optical equalizer Band AB
12.1(10)EV1
15500-PEQ-02CD
Dual band optical equalizer Band CD
12.1(10)EV1
15500-PEQ-02EF
Dual band optical equalizer Band EF
12.1(10)EV1
15500-PEQ-02GH
Dual band optical equalizer Band GH
12.1(10)EV1
Protection switch module
15530-PSM-01
ONS 15530 protection switch module
12.1(12c)EV
Pluggable SFPs
15500-XVRA-08D1
T1 1.544-Mbps
12.2(25)SV
15500-XVRA-09D1
E1 2.048-Mbps
12.2(25)SV
15500-XVRA-10A1
Low band (16 to 200 Mbps) variable rate, MM (1310 nm) with LC
12.1(12c)EV3
15500-XVRA-10A2
HT2 low band 8 to 200 Mbps
12.2(25)SV
15500-XVRA-10B1
Low band (16 to 200 Mbps) variable rate, SM
(1310 nm) with LC12.1(12c)EV3
15500-XVRA-10B2
HT low band 8 to 200-Mbps
12.2(25)SV
15500-XVRA-10E11
SDI & DVB-ASI
12.2(25)SV
15500-XVRA-11A2
HT mid band 200 to 622-Mbps
12.2(25)SV
15500-XVRA-11B1
Mid band (200 to 1250 Mbps) variable rate, SM
(1310 nm) with LC
12.1(12c)EV3
15500-XVRA-11B2
HT mid band 200 to 1.25-Gbps
12.2(25)SV
15500-XVRA-12B1
HT high band 1.062 to 2.488 Gbps
12.1(12c)EV3
15500-XVRA-02C1
Gigabit Ethernet3 , Fibre Channel (1 Gbps)4 , FICON (1 Gbps), MM
12.1(12c)EV
15500-XVRA-03B1
Gigabit Ethernet5 , Fibre Channel (1 Gbps)6 , FICON (1 Gbps), ISC-3 links compatibility mode, SM
12.1(12c)EV
15500-XVRA-03B2
Fibre Channel (1-Gbps and 2-Gbps), SM
12.1(12c)EV
15454-SFP-GEFC-SX
Fibre Channel (2-Gbps), Fibre Channel (1-Gbps), 1000BASE-LX Ethernet, MM
12.2(25)SV
15500-XVRA-11D1
Fast Ethernet (125 Mbps) Gigabit Ethernet (1.25 Gbps)
12.2(25)SV
SFP cable
SMB/BNC
MINISMB/BNC=
12.2(25)SV
AC cables
15500-CAB-AC=
AC North America (spare)
12.1(10)EV1
15500E-CAB-ACA=
ONS 15530 ETSI AC cable, Australia (spare)
12.1(10)EV1
15500E-CAB-ACE=
ONS 15530 ETSI AC cable, Europe (spare)
12.1(10)EV1
15500E-CAB-ACU=
ONS 15530 ETSI AC cable, UK (spare)
12.1(10)EV1
15500E-CAB-ACI=
ONS 15530 ETSI AC cable, Italy (spare)
12.1(10)EV1
15500E-CAB-ACR=
ONS 15530 ETSI AC cable, Argentina (spare)
12.1(10)EV1
Blank panel cover
15530-COV-MUX=
OADM blank panel cover
12.1(10)EV1
15530-COV-SLOT=
Full slot panel cover
12.1(10)EV1
15530-COV-PWR=
Power supply blank panel cover
12.1(10)EV1
15530-COV-OSC=
OSC blank panel cover
12.1(10)EV1
Fan assembly
15530-FT01=
Fan assembly (spare)
12.1(10)EV1
Air ramp baffle
15530-BAF-E=
Air baffle (spare) for 15530-CHAS-E chassis
12.1(10)EV1
CompactFlash card
MEM-15530FLC32M=
CompactFlash card 32 MB
12.1(10)EV1
Rack mount kit
15530-RKMT-E=
Chassis rack mount kit for 15530-CHAS-E
12.1(10)EV1
15530-RKMT-N23=
Chassis rack mount kit for 15530-CHAS-N (23 inch rack)
12.1(10)EV1
15530-RKMT-N19=
Chassis rack mount kit for 15530-CHAS-N (19 inch rack)
12.1(10)EV1
1 The software version listed might be deferred.
2 HT = high temperature.
3 1000BASE-SX.
4 FC-0-100-M5-SN-S and FC-0-100-M6-SN-S standards.
5 1000BASE-LX.
6 FC-0-100-SM-LC-S standard.
Determining the Software Version
Note We strongly recommend that you use the latest available software release for all Cisco ONS 15530 hardware.
To determine the version of Cisco IOS software currently running on a Cisco ONS 15530 system, log in to the system and enter the show version EXEC command. The following sample output is from the show version command. The software version number is shown on the second line of the sample output.
Switch# show version
Cisco Internetwork Operating System Software
IOS (tm) ONS-15530 Software (ONS15530-I-M), Version 12.2(29)SV1 <Information deleted>
Upgrading the System Image
To ensure proper system functioning, follow the system image upgrading procedure described in the Cisco ONS 15530 Software Upgrade Guide.
You can find the system images for the Cisco ONS 15530 at the following URL:
http://www.cisco.com/kobayashi/sw-center/sw-optical.shtml
Note Always set the configuration register to 0x2102 when upgrading the system image using the config-reg 0x2102 command in configuration mode.
Caution Improper system image upgrades can affect system functioning and redundancy. Always follow the recommended upgrade procedures.
Feature Set Table
The Cisco IOS Release software is packaged in feature sets (also called software images) depending on the platform. Each feature set contains a specific set of Cisco IOS features. Table 2 lists the Cisco IOS software feature sets available for the Cisco ONS 15530.
Table 2 Feature Sets Supported by the Cisco ONS 15530
Feature Set Introduced in This ReleaseInband message channel
12.1(10)EV2
Gigabit Ethernet
12.1(10)EV2
Fast Ethernet
12.1(10)EV2
Ethernet
12.1(10)EV2
ATM OC-3/STM-1, OC-12/STM-4, and OC-48/STM-16
12.1(10)EV2
12.1(10)EV2
POS3
12.1(10)EV2
IBM Sysplex coupling link
12.1(10)EV2
Fibre Channel (1 Gbps)
12.1(10)EV2
Fibre Channel (2 Gbps)
12.1(10)EV2
FDDI4
12.1(10)EV2
ESCON5 aggregation (2.5 Gbps)
12.1(10)EV2
FICON6 (1 Gbps)
12.1(10)EV2
FICON (2 Gbps)
12.1(10)EV2
Token ring
12.1(10)EV2
SNMP
12.1(10)EV2
CiscoView
12.1(10)EV2
Cisco Transport Manager
12.1(10)EV2
IP packets
12.1(10)EV2
OSCP7
12.1(10)EV2
APS8 channel protocol
12.1(10)EV2
Point-to-point
12.1(10)EV2
Hubbed ring
12.1(10)EV2
Meshed ring
12.1(10)EV2
IBM Sysplex ETR/CLO9
12.1(10)EV2
1-Gbps Fibre Channel/FICON aggregation into 2.5 Gbps transponder modules
12.1(12c)EV
1-Gbps IBM Sysplex Coupling Link aggregation into 2.5 Gbps transponder modules
12.2(18)SV
Gigabit Ethernet aggregation (2.5 Gbps)
12.1(12c)EV
Buffer credit support on the 8-port FC/GE aggregation card
12.2(18)SV
2-Gbps Fibre Channel protocol monitoring on transponder line cards
12.2(18)SV
2-Gbps FICON protocol monitoring on transponder line cards
12.2(18)SV
Functional image version diagnostics
12.2(18)SV
Autonegotiation for Gigabit Ethernet between the 8-port FC/GE aggregation card and the client equipment
12.2(18)SV
ISC links compatibility mode aggregation (2.5 Gbps) for the 8-port FC/GE aggregation card
12.2(18)SV
2-Gbps ISC links peer mode protocol monitoring on transponder line cards
12.2(22)SV
ISC links compatibility mode aggregation (2.5 Gbps) on the 4-port 1-Gbps/2-Gbps FC aggregation card
12.2(23)SV
1-Gbps and 2-Gbps ISC-3 peer mode support on the 4-port 1-Gbps/2-Gbps FC aggregation card
12.2(23)SV
2-Gbps Fibre Channel/FICON aggregation into 2.5-Gbps signals on 4-port 1-Gbps/2-Gbps FC aggregation cards
12.2(23)SV
Buffer credit support on the 4-port 1-Gbps/2-Gbps FC aggregation card
12.2(23)SV
1-Gbps ISC links peer mode on the transponder line card
12.2(23)SV
SSHv1 client and server support
12.2(24)SV
SNMPv3 support
12.2(24)SV
Counter preservation on CPU switch module switchovers
12.2(24)SV
1-Gbps peer mode ISC-3 on the 8-port FC/GE aggregation card
12.2(24)SV
8-port multi-service muxponder
12.2(25)SV
10-Gbps ITU tunable trunk card, which can be tuned to four channels
12.2(26)SV
End-to-end speed negotiation support on the 4-port 1-Gbps/2-Gbps FC aggregation card
12.2(29)SV
Oversubscription support on the 4-port 1-Gbps/2-Gbps FC aggregation card
12.2(29)SV
Superportgroup support on the 4-port 1-Gbps/2-Gbps FC aggregation card
12.2(29)SV
Performance history counter support on Cisco ONS 15530 line cards
12.2(29)SV
SSHv2 support on Cisco ONS 15530
12.2(29)SV
Critical temperature shutdown support on Cisco ONS 15530. Temperature alarm thresholds can be configured.
12.2(29)SV
1 SONET = Synchronous Optical Networking
2 SDH = Synchronous Digital Hierarchy
3 POS = Packet over SONET
4 FDDI = Fiber Distributed Data Interface
5 ESCON = Enterprise Systems Connection
6 FICON = Fiber Connection
7 OSCP = Optical Supervisory Channel Protocol
8 APS = Automatic Protection Switching
9 ETR/CLO = external timer reference/control link oscillator
New and Changed Information
This section lists new features that appear in this and previous releases of Cisco IOS Release 12.2. The new features are sorted by release number.
New Features in Release 12.2(29)SV1
There are no new features for this release.
New Features in Release 12.2(29)SV
The following new software features are available for the Cisco ONS 15530 in Cisco IOS Release 12.2(29)SV:
•End-to-end speed negotiation support on the 4-port 1-Gbps/2-Gbps FC aggregation card.
•Oversubscription support on the 4-port 1-Gbps/2-Gbps FC aggregation card.
•Superportgroup support on the 4-port 1-Gbps/2-Gbps FC aggregation card.
Note To enable end-to-end speed negotiation, oversubscription, or superportgroup, 4-port 1-Gbps/2-Gbps FC aggregation cards with Functional version 1.20 or later must be used at both ends.
•Performance history counter support on Cisco ONS 15530 line cards.
•SSHv2 support.
•Critical temperature shutdown and configurable temperature alarm thresholds are supported.
New Features in Release 12.2(26)SV1
There are no new features for this release.
New Features in Release 12.2(26)SV
The following new hardware is available for the Cisco ONS 15530 in Cisco IOS Release 12.2(26)SV:
•10-Gbps ITU tunable trunk card, with four channel tunability
New Features in Release 12.2(25)SV
The following new hardware is available for the Cisco ONS 15530 in Cisco IOS Release 12.2(25)SV:
•8-port multi-service muxponder
New Features in Release 12.2(24)SV
The following new software features are available for the Cisco ONS 15530 in Cisco IOS Release 12.2(24)SV:
•SSHv1 client and server support
•SNMPv3 support
•Counter preservation on CPU Switchovers
•ISC-3 1-Gbps (peer mode) support on the 8-port FC/GE aggregation card
New Features in Release 12.2(23)SV
The following new hardware is available for the Cisco ONS 15530 in Cisco IOS Release 12.2(23)SV:
•4-port 1-Gbps/2-Gbps FC aggregation card
The following new software feature is available for the Cisco ONS 15530 in Cisco IOS Release 12.2(23)SV:
•1-Gbps ISC-3 peer mode support on all ISC interfaces, except the 8-port FC/GE aggregation card
New Features in Release 12.2(22)SV
The following new software feature is available for the Cisco ONS 15530 in Cisco IOS Release 12.2(22)SV:
•2-Gbps ISC peer mode protocol monitoring on 2.5-Gbps transponder line cards
New Features in Release 12.2(18)SV2
No new features are available for this release.
New Features in Release 12.2(18)SV1
No new features are available for this release.
New Features in Release 12.2(18)SV
The following new software features are available for the Cisco ONS 15530 in Cisco IOS Release 12.2(18)SV:
•Autonegotiation between the 8-port FC/GE aggregation card and the client equipment for Gigabit Ethernet traffic
Note The 8-port FC/GE aggregation card does not support end-to-end pass through of autonegotiation parameters in functional image release 2.29 or earlier. End-to-end negotiation is supported in functional image release 2.30 or later.
•ISC links compatibility mode aggregation (2.5 Gbps)
•Buffer credits for Fibre Channel distance extension
•2-Gbps Fibre Channel protocol monitoring on 2.5-Gbps transponder modules
Note 2-Gbps Fibre Channel protocol monitoring requires transponder functional image
release 1.A3.•2-Gbps FICON protocol monitoring on 2.5-Gbps transponder modules
Note 2-Gbps Fibre Channel protocol monitoring requires transponder functional image
release 1.A3.•Data file with upgrade information for the ROMMON and functional images
•show upgrade-info functional-image command
•negotiation auto command
•flow control command
Caveats
This section describes open and resolved severity 1 and 2 caveats and some severity 3 caveats. The "Open Caveats" section lists open caveats that apply to the current release and may apply to previous releases. The "Resolved Caveats" sections list caveats resolved in a particular release, but open in previous releases.
Open Caveats in Release 12.2(29)SV1
•CSCsb85494
Symptom: CRC errors are observed on the FC client devices that are connected to the 4-port 1-Gbps/2-Gbps FC aggregation card when jumbo GE traffic is mixed on the same trunk.
Conditions: This symptom is seen when the GE traffic (with frame size greater than 1500 bytes) and the FC traffic from the 4-port 1-Gbps/2-Gbps FC aggregation card pass through the same 10-Gbps trunk card.
Workaround: None.
•CSCed74239
Symptom: Though the working trunk has a failure, the protection path may not become active for a Y-cable APS link when the client device is administratively shutdown and restarted.
Conditions: The symptom may be observed on some FC devices connected to the 2.5-Gbps transparent transponder cards.
Workaround: Configure a loopback interface on the client side to restore the traffic.
•CSCsc14597
Symptom: When end-to-end speed negotiation is enabled on all the twogigabitphy interfaces of the 4-port 1-Gbps/2-Gbps FC aggregation card and the FC client devices, the interface may lock to 1 Gbps even though the maximum negotiable speed is 2 Gbps.
Workaround: Perform any of the following operations:
–Perform shut/no shut on both the twogigabitphy interfaces of the 4-port 1-Gbps/2-Gbps FC aggregation card.
–Perform shut/no shut on the client interface.
–Perform encapsulation/no encapsulation on both the twogigabitphy interfaces of the 4-port 1-Gbps/2-Gbps FC aggregation card.
•CSCdz59146
Symptom: The ethernetdcc interface loses connectivity when splitter protection is configured and the waveethernetphy interface is shut down while the protection wavepatch interface is active and the working wavepatch interface is down.
Workaround: Do not shut down the waveethernetphy interface when the working wavepatch interface is down.
•CSCec25368
Symptom: The values returned for entPhysicalVendorType and entPhysicalName are wrong when a low-band single-mode SFP is present in an ESCON aggregation card. The values returned show a low-band multimode SFP instead.
Workaround: None.
•CSCee56524
Symptom: Tracebacks related to CPU switch module hog issues occur after installing an 8-port multi-service muxponder after booting up the box.
Workaround: None.
•CSCef74226
Symptom: When upgrading from Cisco IOS Release 12.1(10)EV4 or Cisco IOS Release 12.1(12c)EV to a later image using standard CPU switch module switchover procedure, the high water mark threshold for the ESCON aggregation card is not programmed to the new value. This might cause higher than expected delays on ESCON streams.
Workaround: Use the escon write <slot_no> 0x1C4 0x40 command to set the high water mark to the correct value for all ports on the ESCON aggregation card. Use the show controller port x/y/z command to display the new value.
•CSCef12108
Symptom: The Cisco ONS15530 might not allow you to connect to the standby CPU switch module due to an authentication failure. This occurs when AAA or a local database is used for user authentication as this information (AAA or local database) is not replicated from the active to the standby CPU switch module.
Workaround: None.
•CSCef87165
Symptom: An end-to-end link will remain down even if the initial condition that caused the fault is rectified if speed negotiation is enabled on the Fibre Channel switches, FLC is enabled on the corresponding multirate interfaces, and if the link between any one of the multirate interfaces and the FC switch goes down
Workaround: Disable FLC on the multirate interfaces.
•CSCeg06084
Symptom: When autonegotiation is enabled on the CuFE multirate port and the peer device is hardcoded to 100 Mbps full duplex, the link might not come up.
Workaround: Issue the no negotiation auto command to disable autonegotiation on the CuFE port on the 8-port multi-service muxponder.
•CSCeg23905
Symptom: A terminal loopback on a multirate interface might not work if the interface is in Loss of Light condition.
Workaround: Clear the Loss of Light condition and then configure terminal loopback.
•CSCeg32098
Symptom: The AMI linecoding and the line build out options to specify the cable length are not available for T1 and E1 encapsulations of multirate interfaces.
Workaround: None.
•CSCin81028
Symptom: Terminal and facility loopback do not work on the multirate interfaces after a CPU switch module switchover.
Workaround: Reconfigure the client encapsulation.
•CSCin82637
Symptom: Version compatibility check is not performed on the mux/demux modules and PSM. No warning is issued if there is a version mismatch in hardware and software.
Workaround: None.
•CSCin86897
Symptom: A temporary traffic interruption in 2.5G transparent transponders during ONS 15540 and 15530 CPU switchover. This depends on the software versions of the Active CPU before and after the switchover.
Conditions: This can occur when switching from a CPU that is running on IOS software without the fix for CSCec64326, to a CPU running on IOS software with the fix for CSCec64326. The fix for CSCec64326 involves changes to hardware settings, causing the temporary datahit.
Workaround: None. The problem will be fixed in a future release of IOS software.
•CSCsa75221
Symptom: On an ONS15530 system, the cross connections belonging to a 4-Port FC card are lost during software upgrade. This is found when upgrading from any IOS image released before 12.2(25)SV, to any IOS image released in or after 12.2(25)SV.
Workaround: None
•CSCsa99359
Symptom: For 15530 multirate cards, the 'encap mismatch' alarm asserts if the encapsulation configured on a multirate interface doesn't match with the encapsulation configured on the peer multirate interface. This alarm is not reported on the 'sh facility-alarm status ' output.
Workaround: None
•CSCsb01894
Symptom: In ONS 15530, the standby CPU gets reloaded while downgrading from 12.2(26)SV to 12.2(24)SV, if the counter syncing feature in the 8p-GEFC card is enabled.
Workaround: Disable counter syncing on the primary CPU that runs on 12.2(26)SV and then reload 12.2(24)SV on the standby CPU.
Resolved Caveats in Release 12.2(29)SV1
•CSCsb77838
Symptom: Though the working trunk has a failure, the protection path may not become active for a Y-cable APS link when the client device is administratively shutdown and restarted.
Condition: The symptom may be observed on some FC devices connected to the following cards:
–4-port 1-Gbps/2-Gbps FC aggregation cards in Cisco ONS 15530 running Cisco IOS Release 12.2(26)SV or later.
–8-port Fibre Channel/Gigabit Ethernet aggregation cards in Cisco ONS 15530 running Cisco IOS Release 12.2(26)SV or later.
Workaround: Configure a loopback interface on the client side to restore the traffic.
•CSCsd61174
Symptom: The active CPU may reload when a power failure is caused to a Cisco ONS 15530 linecard.
Condition: This symptom is observed rarely.
Workaround: None.
•CSCsd40488
Symptom: The performance history counters for the wave interface of the 2.5-Gbps transparent transponder linecards are not displayed.
Condition: None.
Workaround: None.
•CSCsd43471
Symptom: The CVRD thresholds are incorrectly displayed in the show interface output for FC 1 Gbps and FC 2 Gbps encapsulations. These thresholds are used in the 2.5-Gbps transparent transponder linecards, 4-port 1-Gbps/2-Gbps FC aggregation cards, and 8-port Fibre Channel/Gigabit Ethernet aggregation cards.
Condition: None.
Workaround: None.
•CSCsd12813
Symptom: The help string for the sdh encapsulation STM-16 rate configuration is incorrect for the 2.5-Gbps transparent transponder.
Condition: None.
Workaround: None.
•CSCin86829
Symptom: The PSM hardware supports optical power monitoring of the wdmsplit interfaces only for a specific range (0 to -24 dBm). The software does not extrapolate for the other power levels (up to 17 dBm) around the hardware supported range.
Condition: None.
Workaround: None.
•CSCsd21153
Symptom: Switch fabric protection may not get enabled for the 4-port 1-Gbps/2-Gbps FC aggregation card.
Condition: This problem occurs when keepalive timeout (KATO) is asserted on the twogigabitphy interfaces.
Workaround: None.
•CSCsa87583
Symptom: The switch fabric protection may not be enabled when the standby CPU is booted, and the following error message is displayed:
00:02:03: %SRC-3-AFOVEN_ERROR: Attempt to enable switch fabric protection autofailover on interface WaveEthernetPhy2/0.1 when port status is 3
Condition: This symptom is observed rarely.
Workaround: Reload the standby CPU.
Resolved Caveats in Release 12.2(29)SV
•CSCsb26802
Symptom: When a client or trunk laser fails, the show facility-alarm status command displays the Line laser failure detected error message. However, this error message does not indicate which laser has failed.
Condition: This symptom is observed on Cisco ONS 15530 cards when transparent transponders are present.
Workaround: None.
•CSCeg27643
Symptom: After a CPU switch module switchover, the trunk transmit laser comes up even if it was shut down before the switchover. The laser shutdown configuration is present in the running configuration, but the laser is still enabled.
Workaround: Issue the laser shutdown command again after the switchover.
•CSCin79007
Symptom: Even though forward laser control is not configured, the client laser is disabled if an OIR is performed when a keepalive timeout exists on the twogigabitphy interface. The laser is enabled when the keepalive timeout condition is cleared, but it is disabled whenever a keepalive timeout condition is asserted. The client laser shuts down because the keepalive timeout should only be seen under the following conditions:
–The portgroup is not cross-connected to a trunk port.
–Forward laser control (FLC) is configured on the client interface.
Condition: This behavior is seen only on the x/0/0 twogigabitphy interface of the 4-port 1-Gbps/2-Gbps FC aggregation card if it is removed and reinserted when the interface is in keepalive timeout condition.
Workaround: Change the encapsulation to a different value and then change back to the required encapsulation value.
•CSCee70185
Symptom: An informational warning is issued instead of a critical alarm when the line cards are shut down in response to a multiple fan failure event after issuing the environment-monitor shutdown fan command.
Workaround: None.
•CSCsa57880
Symptom: The client laser of the 8-port Fibre Channel/Gigabit Ethernet aggregation card interface that is connected to the ITU trunk card goes down momentarily, when splitter protection switching occurs on the ITU trunk card.
Conditions: This symptom occurs when the Forward Laser Control is enabled on the gigabitphy interface of the 8-port Fibre Channel/Gigabit Ethernet aggregation card.
Workaround: None.
•CSCsb34520
Symptom: Traffic passing through the 8-port FC/GE aggregation card takes a severe hit during a CPU switchover.
Conditions: This symptom occurs during a CPU switchover.
Workaround: None.
•CSCsb25277
A new
idle-pattern
CVRD
configuration option has been introduced for twogigabitphy interfaces of the 4-port 1-Gbps/2-Gbps FC aggregation card. If this option is enabled, the twogigabitphy interface will transmit code violations instead of link control frames on trunk APS switchover; thereby reducing the traffic hit.•CSCsb64798
A new
idle-pattern
CVRD
configuration option has been introduced for gigabitphy interfaces of the 8-port FC/GE aggregation card. If this option is enabled, the twogigabitphy interface will transmit code violations instead of link control frames on trunk APS switchover; thereby reducing the traffic hit.•CSCsc92821
Symptom: The crypto key on the secondary CPU gets deleted a few hours after it syncs up with the primary CPU. If a CPU switchover occurs after the crypto key is deleted, the SSH server gets disabled.
Conditions: None.
Workaround: None.
•CSCsd14510
Symptom: The node may crash if you OIR (Online Insertion and Removal) the SFP, or perform a no shut on the gigabitphy interface.
Conditions: This symptom is observed if you:
–OIR the SFP when FICON encapsulation and Tx CRC thresholds are configured on the gigabitphy interface.
–perform no shut on the gigabitphy interface when FICON encapsulation and Tx CRC thresholds are configured on all the gigabitphy interfaces while they are in the shut mode.
Workaround: Remove the Tx CRC threshold configuration on the gigabitphy interface.
•CSCsa71267
Symptom: The Cisco ONS 15530 system does not shutdown if the fan tray is removed or is faulty.
Conditions: None.
Workaround: None.
•CSCsb37681
Symptom: The Cisco ONS 15530 ITU3 2.5-Gbps trunk card may falsely report the following laser degradation alarms:
%LC_2P5G-3-LASER_DEGRADATION_ALARM: Optic Laser Degradation Alarm submit for Slot
%LC_2P5G-3-MIB_LASER_DEG_ALM: Laser Degradation Alarm ASSERT MAJOR 2.5
These alarms are logged for a short period (less than 30 seconds). When these alarms are present, neither the traffic nor the power level of the optical signal received at the peer node takes a hit.
Conditions: None.
Workaround: Ignore these false alarms.
•CSCsc48011
Symptom: The splitter APS for the ITU2 trunk card does not switchover to the protection card when the CVRD error thresholds are exceeded.
Conditions: None.
Workaround: None.
•CSCsc51135
Symptom: The following false error message is displayed if you configure the twogigabitphy interface of the 4-port 1-Gbps/2-Gbps FC aggregation card to operate at 2 Gbps:
Encap rate mismatched: [TwoGigabitPhy8/0/0, encap rate 2G].
SFP transciever support maximum rate is 1G. Performance at other rates is not guaranteed.
Conditions: This symptom is observed with high-band SM variable rate SFP optics.
Workaround: Ignore this false alarm.
•CSCsc80540
Symptom: The
show facilility-alarm status
command displays incorrect LSC information.Conditions: This condition occurs rarely when the optical switch of the ITU2 card fails.
Workaround: None.
•CSCsc87612
Symptom: A raised
High warning threshold exceeded
facility alarm is not cleared even after the alarm condition is removed.Conditions: This symptom is observed only when the receive signal level is greater than the high warning threshold value.
Workaround: To clear the alarm, you must:
–Reload the active CPU.
–Force an APS switchover.
•CSCsd12809
Symptom: The trunk side ITU laser of the 8-port multirate card may report false laser degradation alarms. These alarms are logged for a short period (less than 30 seconds). When these alarms are present, neither the traffic nor the power level of the optical signal received at the peer node takes a hit.
Conditions: None.
Workaround: Ignore these false alarms.
•CSCsb35798
Symptom: The Cisco ONS 15530 node may reload on performing shut/no shut on the wavee or wavepatch interface.
Conditions: This symptom is observed if the optical monitoring trap is enabled on the node.
Workaround: None.
Resolved Caveats in Release 12.2(26)SV1
•CSCei61732
Cisco IOS may permit arbitrary code execution after exploitation of a heap-based buffer overflow vulnerability. Cisco has included additional integrity checks in its software, as further described below, that are intended to reduce the likelihood of arbitrary code execution.
Cisco has made free software available that includes the additional integrity checks for affected customers.
This advisory is posted at http://www.cisco.com/warp/public/707/cisco-sa-20051102-timers.shtml.
•CSCuk58617
Symptom: The physical Performance Monitoring (PM) statistics may not be collected correctly.
Condition: This symptom is observed on a Cisco ONS15500 series card that is configured for SNMP when optical monitoring traps are enabled.
Workaround: None.
•CSCei25594
Symptom: Memory leak may occur when CiscoView is used to monitor a router.
Condition: This condition may be seen on routers running 12.2(26)SV.
Workaround: None.
Resolved Caveats in Release 12.2(26)SV
•CSCec73572
Symptom: Duplicate frames may be delivered to clients on the ONS15530, in the case of manual aps switchover (by operator command) with line card aps, from one trunk linecard to another.
Conditions: This could occur when the switchover is made from a trunk connected through shorter path to a trunk connected through longer path.
Workaround: None.
•CSCef97070
Symptom: The APS switch time is greater than 50 ms.
Condition: Several APS switching between w and p in a row.
Workaround: None.
•CSCeg02811
Symptom: The power-on diagnostics loopback tests of a Cisco ONS 15530 8-port FC/GE aggregation card (15530-FCGE-8P) may report failure.
Conditions: This symptom is observed very rarely when the Cisco ONS 15530 is booted immediately after a power-cycle.
Workaround: None. However, it does not affect any functionality.
•CSCeg11241
Symptom: The variable rate high-band single mode SFP (15500-XVRA-12B1) is reported as "unknown" in the system status outputs such as show interface and show controller. The Cisco IOS software allows the interface configuration to proceed normally and traffic is not affected. Traffic flows normally once the port configuration is completed.
Conditions: This symptom is observed in 15500-XVRA-12B1 (10-1844-xx) SFP transceiver, on 15530-FCGE-8P and 15530-FC-4P linecards. It is also observed with Cisco IOS versions up to and including 12.2(24)SV and 12.2(25)S1.
Workaround: None.
•CSCeg38355
Symptom: The standby CPU switch module might reload when you upgrade from Release 12.2(24)SV to Release 12.2(25)SV if you are using an 8-port GE/FC aggregation card with the counter synchronization feature enabled.
Workaround: Disable counter synchronization on the primary CPU switch module running Release 12.2(24)SV and then download Release 12.2(25)SV onto the standby CPU switch module.
•CSCeg84037
Symptom: When a CPU switchover is performed (or triggered) on an ONS 15540 or ONS 15530 system, the memory utilization on the new primary increases by 10MB. In such a case, the memory utilization may go up to 85%. This problem is seen only with 12.2 based images.
Workaround: None
•CSCin81342
Symptom: During a CPU switch module switchover, transparent transponders might experience temporary traffic interruption until the switchover is completed. The behavior is intermittent and not all transponders in a given chassis may be affected. This interruption might happen for the following types of protocol encapsulations:
–ETR/CLO
–100 Mbps Fast Ethernet / FDDI
–ESCON/SBCON
–1-Gbps FC/FICON
–1-Gbps ISC ((ISC-1, ISC-3 peer mode, 1 Gbps)
–2-Gbps FC/FICON
–2-Gbps ISC (ISC-3 peer mode, 2 Gbps).
•CSCin86185
Symptom: The received and transmit frame counts are not displayed for Gigabit Ethernet encapsulation on ONS 15530 8-port GigE/FC card.
Workaround: None.
•CSCsa45294
Symptom: Traffic is disrupted for one to two seconds on ONS 155xx transponders configured with Forward Laser Control, when a protection switchover occurs on a trunk Protection Switch Module (PSM). This exceeds the specification of 50ms maximum failover time for the optical transport layer.
Workaround: Disable FLC on trunk-to-client direction of transponder, if feasible for the service. This workaround does not apply for ISC, ETR or CLO services.
Resolution: This will be fixed in the future release of IOS software on ONS15530 and ONS15540, with a caveat that the following configuration will not be supported on the platform:
–Transponder motherboard or linecard with on-board optical splitter module (even if the optical splitter is disabled by configuration)
–Trunk protection with Protection Switch Module
–Forward Laser Control enabled on transponder
•CSCsa46389
Symptom: On an ONS 15540/15530 system with Protection Switch Module, if a CPU switch occurs with the APS state such that protect interface is active and working interface is standby, then after the new CPU comes up there will be an extra APS switch to working. This is seen with all ONS15540 and ONS15530 software based on 12.1 and 12.2.
Workaround: None
•CSCsa89956
Symptom: On an ONS 15530 system, the system may stop responding and reload, when a threshold group is configured on the waveethernetphy interface of an itu trunk card.
Conditions: This occurs only when the traffic is flowing with crc errors.
Workaround: None
Resolved Caveats in Release 12.2(25)SV
•CSCin76822
Symptom: If a failed subcard is replaced by a new one, the show diag online output continues to indicate that there was a 'previous failure' for this subcard. This should have been cleared when the new card was inserted. This is specific to subcards, for motherboards the older failures are cleared when a new card is inserted.
Workaround: None.
Resolved Caveats in Release 12.2(24)SV
•CSCdz82276
Symptom: A warning is issued if the card has an unknown functional image. Version compatibility checks need to be performed during system initialization. The hardware version compatibility should identify any mismatch between functional image versions and hardware versions. The software version compatibility should identify any mismatch between functional image and software image.
•CSCea52092
Symptom: After booting the system, optical power coming out of the OSC module seems to be null even though the laser is enabled.
Workaround: Perform an online removal and insertion of the OSC module or carrier motherboard.
•CSCec45305
Symptom: If the transparent interface on a multimode transponder line card is configured for Sysplex ETR traffic (encap sysplex etr command), the show interfaces transparent command output shows that forward laser control is set to off. Forward laser control is automatically enabled for Sysplex ETR.
Workaround: Add client input traffic and the trunk side laser will function.
•CSCec78648
Symptom: The show redundancy command is not valid on specific versions of the Cisco ONS 15530 software but the choice still exists.
Workaround: Use the show redundancy summary command.
•CSCed28094
Symptom: End-to-end GE autonegotiation is not supported by the 8-port FC/GE aggregation card.
Link defects such as a broken fiber from the 8-port FC/GE aggregation card to the client device at one end, which are not directly detected by the Cisco ONS 15530 and cause the client at one end to initiate autonegotiation, are not propagated to the client at the other end.
Any upper-layer processes that depend on bidirectional defect detection and propagation at the transport level might fail for certain classes of link defects.
Workaround: None.
Resolution: Upgrade the 8-port FC/GE aggregation card functional image to Release 2.30 or later.
•CSCee22677
Symptom: When a Cisco ONS 15530 is connected to a Catalyst 450x through the gigabitphy interface of the 8-port FC/GE aggregation card, it is possible that the link will remain down after the link goes down on any reason. Conditions for this to happen are as follows:
–Auto negotiation is disabled on both the GE interfaces, the Catalyst 4000 interface and the gigabitphy interface of the 8-port FC/GE aggregation card on the Cisco ONS 15530.
–FLC is enabled on the gigabitphy interface.
Workaround: Enable autonegotiation on the GE interface level of the Catalyst 4500 at no speed nonegotiate and at negotiation auto for the Cisco ONS 15530.
•CSCee50294
Symptom: Cisco IOS® devices running branches of Cisco IOS version 12.2S that have Dynamic Host Configuration Protocol (DHCP) server or relay agent enabled, even if not configured, are vulnerable to a denial of service where the input queue becomes blocked when receiving specifically crafted DHCP packets. Cisco is providing free fixed software to address this issue. There are also workarounds to mitigate this vulnerability. This issue was introduced by the fix included in CSCdx46180 and is being tracked by Cisco Bug ID CSCee50294.
This advisory is available at
http://www.cisco.com/warp/public/707/cisco-sa-20041110-dhcp.shtml.
Workaround: None.
•CSCee75578
Symptom: The GE optical link fails to come up between two Catalyst 65xx 8-port GBIC modules through the Cisco ONS155xx transparent transponders when Forward Laser Control (FLC) is enabled on the system. The link fails to come up irrespective of the type of protection scheme.
Workaround: Use a 16-port GBIC module on the Catalyst 65xx or deactivate FLC on the ONS155xx.
•CSCef28950
Symptom: The frame and bit 5-minute input and output rates are missing in the show interface command output of twogigabitphy interfaces on the 4-port 1-Gbps/2-Gbps FC aggregation cards configured for encapsulation for Sysplex ISC.
Workaround: None.
•CSCef28967
Symptom: Tx CRC counts are displayed in the show interface command output of twogigabitphy interfaces on the 4-port 1-Gbps/2-Gbps FC aggregation cards configured for encapsulation for Sysplex ISC, even though these counts are not monitored.
Workaround: Ignore the Tx CRC count in the show interface command output for ISC encapsulation.
•CSCin69960
Symptom: A receive failure might display a message that the laser is shut due to forward laser control.
Workaround: None.
Resolved Caveats in Release 12.2(23)SV
•CSCed38657
Symptom: DWDM links set at a 196.608-Mbps rate, or an uncommon rate close to this, may not work properly on the 2.5-Gbps transponder line card. Link initialization failures and bit errors may occur.
Workaround: None.
•CSCee24673
Symptom: High capacity counters are not implemented but are needed.
Workaround: None.
•CSCee34107
Symptoms: APS behavior for the aps clear command is inconsistent with the standard behavior when the following conditions occur:
–Traffic runs from the working link (link A) and you perform a manual switch to the protected link (link B), causing traffic to switch to link B.
–You enter the aps clear command for the aps-group; link A becomes active, regardless of whether the APS group is configured revertively or nonrevertively.
Workaround: None.
•CSCee59383
Symptom: The entitySensorMIB is not implemented.
Workaround: None.
•CSCeb70408
Symptom: The IDPROM values from the high band single-mode SFPs are not readable. The SFPs cannot be configured and cannot be used.
Workaround: None.
•CSCin73872
Symptom: The command for configuring optical thresholds on a voain interface is broken in Cisco IOS Release 12.2(22)SV for the Cisco ONS 15530. The command should be in the form:
optical threshold power receive after-attenuation [low|high] [alarm|warning] <val>
But in Cisco IOS release 12.2(22)SV only the following command can be specified in the interface configuration mode:
optical threshold power receive [low|high] [alarm|warning] <val>
The command is stored in an earlier format in the running configuration for the interface; hence upon reloading the chassis these threshold configurations are lost.
Workaround: Configure the optical threshold using this format:
optical threshold power receive [low|high] [alarm|warning] <val>
If the chassis has to be reloaded, then reconfigure the threshold command again when the box is rebooted.
•CSCin78329
Symptom: Power-on diagnostics may fail the credit-buffer-memory test for the 8-port FC/GE aggregation card on the first boot after power cycling the box. Subsequent reboots without power cycling pass the test. These test failures are spurious and can be ignored.
Workaround: Upgrade your Cisco ONS 15530 software to Cisco IOS Release 12.2(23)SV or later.
Resolved Caveats in Release 12.2(22)SV
•CSCec14447
Symptom: The 8-port GE/FC aggregation card laser is not in the proper state when a Tx-CRC threshold has been exceeded and FLC is configured.
Workaround: Issue the shutdown/no shutdown command sequence on the affected interface.
•CSCec42573
Symptom: In a y-cable APS configuration, interfaces on the 8-port GE/FC aggregation card configured for FICON encapsulation change to GE encapsulation when the saved configuration file is copied to the running configuration.
Workaround: Change the encapsulation back to FICON.
•CSCed33451
Symptom: After configuring a patch between a wavepatch interface and a wdmrelay interface, issuing a show connect intermediate command results in spurious memory access.
Workaround: Do not issue the show connect intermediate command when a patch between a wavepatch interface and a wdmrelay interface is configured.
•CSCed33852
Symptom: The system might reload unexpectedly when a faulty optical add/drop multiplexer (OADM) module is present in the chassis.
Workaround: Replace the faulty OADM module.
•CSCin64935
Symptom: A system might reload unexpectedly when you perform an online removal and reinsertion of a wide-band variable optical attenuator (WB-VOA) module.
Workaround: Do not remove and reinsert a WB-VOA module.
•CSCin65618
Symptom: The system might reload unexpectedly when you configure the alarm threshold on a waveethernetphy interface of a 2.5-Gbps ITU trunk card.
This symptom occurs after the following steps:
1. Configure an alarm threshold list with code violation running disparity (CVRD) signal degrade and failure thresholds and apply it to the waveethernetphy interface.
2. Remove the 2.5-Gbps ITU trunk card, remove the threshold configurations from the threshold list, and reinsert the 2.5-Gbps ITU trunk card.
3. Remove the 2.5-Gbps ITU trunk card again, configure a CVRD degrade threshold, remove the threshold list, and reinsert the 2.5-Gbps ITU trunk card.
After you have performed these steps, the shelf reloads.
Workaround: None.
•CSCin66424
Symptom: An APS switchover from a working interface to a protect interface might not occur for the following modules:
–10-Gbps uplink card
–10-Gbps ITU trunk card
–2.5-Gbps ITU trunk card
This symptom occurs with the following configurations:
–The card is configured for switch fabric based line card protection.
–The interfaces of the card have threshold groups that are configured for converged data link header error checksum (CDL HEC) errors or cyclic redundancy check (CRC) errors, or both.
–The CDL HEC error thresholds or CRC error thresholds, or both, are exceeded.
Workaround: Do not configure CDL HEC error thresholds, CRC error thresholds, or both. Instead, configure code violation running disparity (CVRD) error thresholds. In a configuration in which an APS switchover of a working interface to a protect interface is based on CDL HEC error thresholds, CRC error thresholds, or both, there is no workaround.
•CSCin68117
Symptom: The CLI does not support patch configurations between oscfilter interfaces and voaout interfaces.
Workaround: None.
•CSCeb18103
Symptom: OSC wave interface that is configured for laser safety control does not recover when the OSC link is down because of Loss of Light.
This occurs after the following sequence of events:
–The OSC wave interface is not configured with laser safety control.
–The OSC wave interface goes down with a Loss of Light condition.
–The OSC wave interfaces at both ends are configured for LSC, with more than 3 seconds elapsed between the configurations.
–The Loss of Light failure is resolved.
This problem does not appear if laser safety control is configured when the OSC wave interface is up.
Workaround: None.
Resolution: Upgrade the Cisco ONS 15530 mux/demux motherboard functional image to release 2.67 or later.
•CSCea52092
Symptom: An optical supervisory channel (OSC) module may not provide power even though the laser is enabled after you have booted the shelf.
Workaround: Remove and reinsert the carrier motherboard.
•CSCin60562
Symptom: If a row is created in cApsChanConfigTable using createAndWait, a set operation on an instance of cApsChanConfigIfIndex might modify another instance of that object.
Workaround: Use createAndGo to create the row.
Resolved Caveats in Release 12.2(18)SV2
•CSCeb87507
Symptom: In some instances the system crashes when it attempts to parse IP SNMP related commands.
Workaround: None.
•CSCed05346
Symptom: Bidirectional APS fails when the ethernetdcc interface is used as a message channel for trunk based protection if the PSM is connected directly to a wavepatch interface on an ITU trunk card or transponder line card rather than to the wdm interface on an OADM module.
Workaround: None.
•CSCed22589
Symptom: Link initialization failure due to Loss of Lock might occur for ESCON traffic on some transponder line cards due to a transient failure of the clock recovery unit. Only some transponder line cards are susceptible to this failure and not all. This is an initialization failure and not a run-time failure.
Workaround: None.
Resolved Caveats in Release 12.2(18)SV1
•CSCdz64021
Symptom: While performing an online removal and insertion of a protection card in a y-cable configuration, the local and remote working ports are flooded with CRC errors.
Workaround: Disconnect the standby branch of the y-cable configuration during the insertion of the standby line card or SFP optics.
•CSCec28182
Symptom: Tracebacks related to CPU switch module hog issues are seen when reprogramming the 2.5-Gbps transponder line card functional image.
Workaround: None.
•CSCec36614
Symptom: Performing an online removal and insertion on a tengigethernetphy interface or waveethernetphy interface when loopback is configured causes a loss of the loopback information on the hardware. However, the loopback CLI configuration is still present in the software.
Workaround: Remove and reinsert the line card, and then issue the loopback command.
•CSCec59409
Symptom: Issuing a Ctrl-U when connected to a raw TL1 port causes the system to crash.
Workaround: If a TL1port is unused, apply an IP ACL to the management Ethernet interface that blocks the incoming TCP connections to ports 3082 and 3083.
•CSCec88050
Symptom: Power-on diagnostics fail on the CPU switch module if a 2.5-ITU trunk card is installed in slot 1.
Workaround: None.
Resolved Caveats in Release 12.2(18)SV
•CSCdu53656
A Cisco device running Cisco IOS software and enabled for the Border Gateway Protocol (BGP) is vulnerable to a Denial of Service (DOS) attack from a malformed BGP packet. The BGP is not enabled by default, and must be configured to accept traffic from an explicitly defined peer. Unless the malicious traffic appears to be sourced from a configured, trusted peer, it would be difficult to inject a malformed packet. BGP MD5 is a valid workaround for this problem.
Cisco has made free software available to address this problem. For more details, refer to this advisory, available at http://www.cisco.com/warp/public/707/cisco-sa-20040616-bgp.shtml.
•CSCdz89270
Symptom: OFC (open fibre control) is not supported with Fibre Channel on the 8-port FC/GE aggregation card. The link might not initialize if an 8-port FC/GE aggregation card is used with older Fibre Channel equipment that employ OFC laser safety mechanisms.
Workaround: None.
•CSCea28131
A Cisco device running Cisco IOS software and enabled for the Border Gateway Protocol (BGP) is vulnerable to a Denial of Service (DOS) attack from a malformed BGP packet. The BGP is not enabled by default, and must be configured to accept traffic from an explicitly defined peer. Unless the malicious traffic appears to be sourced from a configured, trusted peer, it would be difficult to inject a malformed packet. BGP MD5 is a valid workaround for this problem.
Cisco has made free software available to address this problem. For more details, refer to this advisory, available at http://www.cisco.com/warp/public/707/cisco-sa-20040616-bgp.shtml.
•CSCeb19410
Symptom: An 8-port FC/GE aggregation card client interface laser may be off when it is configured in a disabled y-cable APS group.
Workaround: Enable and then disable the APS group. This activates the client interface laser.
•CSCec03715
Symptom: If the flow identifier on an esconphy interface is changed without deleting the old flow identifier, both the old and the new flow identifiers are present in the lookup table of the ESCON aggregation card. As a result, the old flow identifier cannot be reused on this ESCON aggregation card.
Workaround: Perform an online removal and insertion of the ESCON aggregation card or issue the following sequence of commands in interface configuration mode:
1. no cdl flow identifier
2. cdl flow identifier [OLD IDENTIFIER]
3. no cdl flow identifier
4. cdl flow identifier [NEW IDENTIFIER]
•CSCec34628
Symptom: Continuous optical power monitoring alarms cause memory leaks that lead to bus error exceptions and an unexpected reload.
Workaround: None.
Limitations and Restrictions
This section provides limitations and restrictions for Cisco ONS 15530 hardware and software.
Transponder Line Cards
This section contains limitations and restrictions that apply to transponder line cards.
•CRC errors might occur with 2-Gbps Fibre Channel on single-mode transponders when high input power levels are received from the client laser sources.
Data errors or link-down conditions for 2-Gbps Fibre Channel might occur when used with certain client laser sources. Transmitters in some client GBIC and SFP transceiver units might send large overshoots in optical power with signal bit transitions, causing momentary overload conditions on the transponder client side receiver. The average transmitted power level from the GBIC does not violate the overload specification of the transponder client side receiver, so a power meter does not detect the overload.
The workaround is to attenuate the signal from the client equipment to a recommended level of -12 dBm when transmitting 2-Gbps Fibre Channel services.
•Error-free transmission of some D1 video signals (defined by the SMPTE 259M standard) and test patterns (such as Matrix SDI) cannot be guaranteed by the Cisco 15500 Series because of the pathological pattern in D1 video. This well-known limitation is usually overcome by the D1 video equipment vendor, who uses a proprietary, second level of scrambling. No standards exist at this time for the second level of scrambling.
8-Port FC/GE Aggregation Card
This section contains limitation and restrictions that apply to 8-port FC/GE aggregation cards.
•IFCCs (InterFace Control Checks) are generated while extending the distance between an IBM mainframe and IBM 9032 Model 5 ESCON Director through FICON using an 8-port FC/GE aggregation card on a Cisco ONS 15530. These IFCCs are seen on the host side. They occur when the port is configured for FICON without flow control enabled.
The FICON bridge port (on the ESCON Director) expects to be connected directly to an N_Port of the host. Therefore, the bridge port expects the N_Port to send a minimum of six primitive signals (Idles and R_RDYs) between frames. Anything less than six primitive signals causes IFCCs to be generated on the ESCON Director, which in turn are logged on the host. The 8-port FC/GE aggregation card is pure transport and needs to delete and insert one IPG for frequency compensation. Hence, depending on the card, sometimes either five or seven idles are sent between frames. The 8-port FC/GE aggregation card cannot maintain six idles between every frame if the card is on slower side of the clock.
The workaround is to enable flow control using the flow control command on the gigabitphy interfaces.
CPU Switch Modules
This section contains limitations and restrictions that apply to CPU switch modules.
•If both CPU switch modules are removed, all aggregation cards, OSC modules, transponder line cards, ITU trunk cards, and uplink cards are shut down.
Note Traffic on pass through optical channels (which passively pass through the OADM modules) are not affected by the removal of the CPU switch modules.
Related Documentation
Use this release notes in conjunction with the following referenced publications:
•Regulatory Compliance and Safety Information for the Cisco ONS 15500 Series
Provides the regulatory compliance and safety information for the Cisco ONS 15500 Series.
•Cisco ONS 15530 Planning Guide
Provides detailed information on the Cisco ONS 15530 architecture and functionality.
•Cisco ONS 15530 Hardware Installation Guide
Provides detailed information about installing the Cisco ONS 15530.
•Cisco ONS 15530 Optical Transport Turn-Up and Test Guide
Provides acceptance testing procedures for Cisco ONS 15530 nodes and networks.
•Cisco ONS 15530 Cleaning Procedures for Fiber Optic Connections
Provides processes and procedures for cleaning the fiber optic connectors and component interfaces of the Cisco ONS 15530.
•Cisco ONS 15530 Command Reference
Provides commands to configure and manage the Cisco ONS 15530.
•Cisco ONS 15530 System Alarms and Error Messages
Describes the system alarms and error messages for the Cisco ONS 15530.
•Cisco ONS 15530 Troubleshooting Guide
Describes how to identify and resolve problems with the Cisco ONS 15530.
•Network Management for the Cisco ONS 15530
Provides information on the network management systems that support the Cisco ONS 15530.
•Cisco ONS 15530 TL1 Commands
Provides a full TL1 command and autonomous message set including parameters, AIDs, conditions and modifiers for the Cisco ONS 15530.
•MIB Quick Reference for the Cisco ONS 15500 Series
Describes the Management Information Base (MIB) objects and explains how to access Cisco public MIBs for the Cisco ONS 15500 Series.
•Cisco ONS 15530 Software Upgrade Guide
Describes how to upgrade system images and functional images on the Cisco ONS 15530.
•Introduction to DWDM Technology
Provides background information on the dense wavelength division multiplexing (DWDM) technology.
•Cisco IOS Configuration Fundamentals Configuration Guide
Provides useful information on the CLI (command-line interface) and basic shelf management.
Document Conventions
This publication uses the following conventions:
Note Means reader take note. Notes contain helpful suggestions or references to material not covered in the document.
Caution Means reader be careful. In this situation, the user might do something that could result in equipment damage or loss of data.
Where to Find Safety and Warning Information
For safety and warning information, refer to the Cisco Optical Transport Products Safety and Compliance Information document that accompanied the product. This publication describes the international agency compliance and safety information for the Cisco ONS 15xxx systems. It also includes translations of the safety warnings that appear in the ONS 15xxx system documentation.
Obtaining Documentation
Cisco documentation and additional literature are available on Cisco.com. Cisco also provides several ways to obtain technical assistance and other technical resources. These sections explain how to obtain technical information from Cisco Systems.
Cisco.com
You can access the most current Cisco documentation at this URL:
http://www.cisco.com/techsupport
You can access the Cisco website at this URL:
You can access international Cisco websites at this URL:
http://www.cisco.com/public/countries_languages.shtml
Product Documentation DVD
The Product Documentation DVD is a comprehensive library of technical product documentation on a portable medium. The DVD enables you to access multiple versions of installation, configuration, and command guides for Cisco hardware and software products. With the DVD, you have access to the same HTML documentation that is found on the Cisco website without being connected to the Internet. Certain products also have .PDF versions of the documentation available.
The Product Documentation DVD is available as a single unit or as a subscription. Registered Cisco.com users (Cisco direct customers) can order a Product Documentation DVD (product number DOC-DOCDVD= or DOC-DOCDVD=SUB) from Cisco Marketplace at this URL:
http://www.cisco.com/go/marketplace/
Cisco Optical Networking Product Documentation CD-ROM
Optical networking-related documentation, including Cisco ONS 15xxx product documentation, is available in a CD-ROM package that ships with your product. The Optical Networking Product Documentation CD-ROM is updated periodically and may be more current than printed documentation.
Ordering Documentation
Registered Cisco.com users may order Cisco documentation at the Product Documentation Store in the Cisco Marketplace at this URL:
http://www.cisco.com/go/marketplace/
Nonregistered Cisco.com users can order technical documentation from 8:00 a.m. to 5:00 p.m. (0800 to 1700) PDT by calling 1 866 463-3487 in the United States and Canada, or elsewhere by calling 011 408 519-5055. You can also order documentation by e-mail at tech-doc-store-mkpl@external.cisco.com or by fax at 1 408 519-5001 in the United States and Canada, or elsewhere at 011 408 519-5001.
Documentation Feedback
You can rate and provide feedback about Cisco technical documents by completing the online feedback form that appears with the technical documents on Cisco.com.
You can submit comments about Cisco documentation by using the response card (if present) behind the front cover of your document or by writing to the following address:
Cisco Systems
Attn: Customer Document Ordering
170 West Tasman Drive
San Jose, CA 95134-9883We appreciate your comments.
Cisco Product Security Overview
Cisco provides a free online Security Vulnerability Policy portal at this URL:
http://www.cisco.com/en/US/products/products_security_vulnerability_policy.html
From this site, you will find information about how to:
•Report security vulnerabilities in Cisco products.
•Obtain assistance with security incidents that involve Cisco products.
•Register to receive security information from Cisco.
A current list of security advisories, security notices, and security responses for Cisco products is available at this URL:
To see security advisories, security notices, and security responses as they are updated in real time, you can subscribe to the Product Security Incident Response Team Really Simple Syndication (PSIRT RSS) feed. Information about how to subscribe to the PSIRT RSS feed is found at this URL:
http://www.cisco.com/en/US/products/products_psirt_rss_feed.html
Reporting Security Problems in Cisco Products
Cisco is committed to delivering secure products. We test our products internally before we release them, and we strive to correct all vulnerabilities quickly. If you think that you have identified a vulnerability in a Cisco product, contact PSIRT:
•For Emergencies only — security-alert@cisco.com
An emergency is either a condition in which a system is under active attack or a condition for which a severe and urgent security vulnerability should be reported. All other conditions are considered nonemergencies.
•For Nonemergencies — psirt@cisco.com
In an emergency, you can also reach PSIRT by telephone:
•1 877 228-7302
•1 408 525-6532
Tip We encourage you to use Pretty Good Privacy (PGP) or a compatible product (for example, GnuPG) to encrypt any sensitive information that you send to Cisco. PSIRT can work with information that has been encrypted with PGP versions 2.x through 9.x.
Never use a revoked or an expired encryption key. The correct public key to use in your correspondence with PSIRT is the one linked in the Contact Summary section of the Security Vulnerability Policy page at this URL:
http://www.cisco.com/en/US/products/products_security_vulnerability_policy.html
The link on this page has the current PGP key ID in use.
If you do not have or use PGP, contact PSIRT at the aforementioned e-mail addresses or phone numbers before sending any sensitive material to find other means of encrypting the data.
Obtaining Technical Assistance
Cisco Technical Support provides 24-hour-a-day award-winning technical assistance. The Cisco Technical Support & Documentation website on Cisco.com features extensive online support resources. In addition, if you have a valid Cisco service contract, Cisco Technical Assistance Center (TAC) engineers provide telephone support. If you do not have a valid Cisco service contract, contact your reseller.
Cisco Technical Support & Documentation Website
The Cisco Technical Support & Documentation website provides online documents and tools for troubleshooting and resolving technical issues with Cisco products and technologies. The website is available 24 hours a day, at this URL:
http://www.cisco.com/techsupport
Access to all tools on the Cisco Technical Support & Documentation website requires a Cisco.com user ID and password. If you have a valid service contract but do not have a user ID or password, you can register at this URL:
http://tools.cisco.com/RPF/register/register.do
Note Use the Cisco Product Identification (CPI) tool to locate your product serial number before submitting a web or phone request for service. You can access the CPI tool from the Cisco Technical Support & Documentation website by clicking the Tools & Resources link under Documentation & Tools. Choose Cisco Product Identification Tool from the Alphabetical Index drop-down list, or click the Cisco Product Identification Tool link under Alerts & RMAs. The CPI tool offers three search options: by product ID or model name; by tree view; or for certain products, by copying and pasting show command output. Search results show an illustration of your product with the serial number label location highlighted. Locate the serial number label on your product and record the information before placing a service call.
Submitting a Service Request
Using the online TAC Service Request Tool is the fastest way to open S3 and S4 service requests. (S3 and S4 service requests are those in which your network is minimally impaired or for which you require product information.) After you describe your situation, the TAC Service Request Tool provides recommended solutions. If your issue is not resolved using the recommended resources, your service request is assigned to a Cisco engineer. The TAC Service Request Tool is located at this URL:
http://www.cisco.com/techsupport/servicerequest
For S1 or S2 service requests, or if you do not have Internet access, contact the Cisco TAC by telephone. (S1 or S2 service requests are those in which your production network is down or severely degraded.) Cisco engineers are assigned immediately to S1 and S2 service requests to help keep your business operations running smoothly.
To open a service request by telephone, use one of the following numbers:
Asia-Pacific: +61 2 8446 7411 (Australia: 1 800 805 227)
EMEA: +32 2 704 55 55
USA: 1 800 553-2447For a complete list of Cisco TAC contacts, go to this URL:
http://www.cisco.com/techsupport/contacts
Definitions of Service Request Severity
To ensure that all service requests are reported in a standard format, Cisco has established severity definitions.
Severity 1 (S1)—An existing network is down, or there is a critical impact to your business operations. You and Cisco will commit all necessary resources around the clock to resolve the situation.
Severity 2 (S2)—Operation of an existing network is severely degraded, or significant aspects of your business operations are negatively affected by inadequate performance of Cisco products. You and Cisco will commit full-time resources during normal business hours to resolve the situation.
Severity 3 (S3)—Operational performance of the network is impaired, while most business operations remain functional. You and Cisco will commit resources during normal business hours to restore service to satisfactory levels.
Severity 4 (S4)—You require information or assistance with Cisco product capabilities, installation, or configuration. There is little or no effect on your business operations.
Obtaining Additional Publications and Information
Information about Cisco products, technologies, and network solutions is available from various online and printed sources.
•The Cisco Product Quick Reference Guide is a handy, compact reference tool that includes brief product overviews, key features, sample part numbers, and abbreviated technical specifications for many Cisco products that are sold through channel partners. It is updated twice a year and includes the latest Cisco offerings. To order and find out more about the Cisco Product Quick Reference Guide, go to this URL:
•Cisco Marketplace provides a variety of Cisco books, reference guides, documentation, and logo merchandise. Visit Cisco Marketplace, the company store, at this URL:
http://www.cisco.com/go/marketplace/
•Cisco Press publishes a wide range of general networking, training and certification titles. Both new and experienced users will benefit from these publications. For current Cisco Press titles and other information, go to Cisco Press at this URL:
•Packet magazine is the Cisco Systems technical user magazine for maximizing Internet and networking investments. Each quarter, Packet delivers coverage of the latest industry trends, technology breakthroughs, and Cisco products and solutions, as well as network deployment and troubleshooting tips, configuration examples, customer case studies, certification and training information, and links to scores of in-depth online resources. You can access Packet magazine at this URL:
•iQ Magazine is the quarterly publication from Cisco Systems designed to help growing companies learn how they can use technology to increase revenue, streamline their business, and expand services. The publication identifies the challenges facing these companies and the technologies to help solve them, using real-world case studies and business strategies to help readers make sound technology investment decisions. You can access iQ Magazine at this URL:
http://www.cisco.com/go/iqmagazine
or view the digital edition at this URL:
http://ciscoiq.texterity.com/ciscoiq/sample/
•Internet Protocol Journal is a quarterly journal published by Cisco Systems for engineering professionals involved in designing, developing, and operating public and private internets and intranets. You can access the Internet Protocol Journal at this URL:
•Networking products offered by Cisco Systems, as well as customer support services, can be obtained at this URL:
http://www.cisco.com/en/US/products/index.html
•Networking Professionals Connection is an interactive website for networking professionals to share questions, suggestions, and information about networking products and technologies with Cisco experts and other networking professionals. Join a discussion at this URL:
http://www.cisco.com/discuss/networking
•World-class networking training is available from Cisco. You can view current offerings at this URL:
http://www.cisco.com/en/US/learning/index.html
This document is to be used in conjunction with the documents listed in the "Related Documentation" section.
Any Internet Protocol (IP) addresses used in this document are not intended to be actual addresses. Any examples, command display output, and figures included in the document are shown for illustrative purposes only. Any use of actual IP addresses in illustrative content is unintentional and coincidental.
© 2006 Cisco Systems, Inc. All rights reserved.
Posted: Mon May 15 01:18:23 PDT 2006
All contents are Copyright © 1992--2006 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.