Configuring Trunk and Uplink Card Interfaces


This chapter describes how to configure 2.5-Gbps ITU trunk cards, 10-Gbps ITU trunk cards, and 10-Gbps uplink cards on the Cisco ONS 15530. This chapter includes the following sections:

Configuring 2.5-Gbps ITU Trunk Card Interfaces

Configuring 10-Gbps ITU Trunk Card Interfaces

Configuring 10-Gbps Uplink Card Interfaces

About Cross Connections

Configuring Cross Connections

About Alarm Thresholds

Configuring Alarm Thresholds

About Patch Connections

Configuring Patch Connections


Note To ensure the installed Cisco IOS software supports your hardware and provides the software features you wish to use, see the "New and Changed Information" section on page xiii. Also refer to the "Hardware Supported" section and "Feature Set" section of the latest release notes for the Cisco ONS 15530.


Configuring 2.5-Gbps ITU Trunk Card Interfaces

To configure the 2.5-Gbps ITU trunk card interface, perform the following tasks, beginning in global configuration mode:

 
Command
Purpose

Step 1

Switch(config)# interface waveethernetphy slot/0

Switch(config-if)#

Selects the interface to configure and enters interface configuration mode.

Step 2

Switch(config-if)# laser frequency number

Selects one of the two frequencies in GHz supported by the laser. The default is the lower frequency for the 2.5-Gbps ITU trunk card. (Optional)

Step 3

Switch(config-if)# [no] loopback [facility | terminal]

Enables or disables internal loopback for testing and defect isolation. (Optional)

Step 4

Switch(config-if)# [no] laser control safety enable

Enables or disables laser safety control.

Step 5

Switch(config-if)# [no] laser shutdown

Turns the laser on and off. (Optional)

Note The laser must warm up for 2 minutes before carrying traffic.

Step 6

Switch(config-if)# [no] cdl defect-indication force hop-endpoint

Enables or disables hop endpoint for in-band message channel defect indications when APS is not configured (Optional).

Step 7

Switch(config-if)# no shutdown

Enables the interface.

Step 8

Switch(config-if)# exit

Switch(config)

Returns to global configuration mode.

Step 9

Switch(config)# interface wavepatch slot/0/0

Switch(config-if)#

Selects the interface to configure and enters interface configuration mode.

Step 10

Switch(config-if)# optical threshold power receive {low | high} {alarm | warning} value [severity {critical | major | minor | not alarmed | not reported}]

Specifies the optical power receive threshold value in units of 0.1 dBm. The default values are as follows:

Low alarm: -28 dBm

Low warning: -26 dBm

High warning: -10 dBm

High alarm: -8 dBm

Alarm severity: major

Warning severity: not alarmed

Step 11

Switch(config-if)# [no] shutdown

Enables or disables the interface.

Repeat Step 9and Step 11 on wavepatch slot/0/1 for splitter 2.5-Gbps ITU trunk cards.


Caution Loopbacks on waveethernetphy interfaces disrupt service. Use this feature with care.

Note For configuration information for the ethernetdcc interface, see the "Configuring IP on Ethernetdcc Interfaces for the In-Band Message Channel" section on page 12-12.


Example

The following example shows how to configure 2.5-Gbps ITU trunk card waveethernetphy interfaces:

Switch(config)# interface waveethernetphy 10/0 Switch(config-if)# cdl defect-indication force hop-endpoint Switch(config-if)# no shutdown

Displaying the 2.5-Gbps ITU Trunk Card Interface Configuration

To display the configuration of 2.5-Gbps ITU trunk card interfaces, use the following EXEC command:

Command
Purpose

show interfaces {waveethernetphy slot/0 | wavepatch slot/0/port}

Displays the interface configuration.


Examples

The following example shows how to display the configuration of a waveethernetphy interface:

Switch# show interfaces waveethernetphy 1/0 WaveEthernetPhy1/0 is up, line protocol is up Channel: 1 Frequency: 192.1 Thz Wavelength: 1560.61 nm Active Wavepatch : Wavepatch1/0/0 Splitter Protected : No Signal quality : Good Receive power level : -6.45 dBm Laser shut down : No Osc physical port : No Wavelength used for inband management: No Loopback not set

Configured threshold Group: None CDL HEC error count: 0 CRC error count: 0 Code violation and running disparity error count( 64b66b cvrd): 0

Defect Indication Status : up Configured Node Behavior : Hop Terminating Current Node Behavior : Hop Terminating Defect Indication Receive : FDI-H FDI-E Defect Indication Transmit : BDI-H

Tx Frames sent to N/W : 218707020912

Tx Frames rcvd from Client : 0 Tx CRC Errors : 0 Tx HEC Errors : 0 Tx QuadPHY sybl Errs : 4257380395 Tx Dropped Frames : 0 Tx Oversize Frames : 0 Tx Undersize Frames : 0 Tx Idle Frames from Fabric : 0 Tx Generated CDL Idle Frames : 218720041509 (having an SII of 255)

Rx Frames rcvd from N/W : 218719304600

Rx Frames sent to Client : 647 Rx CRC Errors : 0 Rx HEC Errors : 0 Rx MII (Decoder) Errors : 0 Rx Dropped Frames : 0 Rx Oversize Frames : 0 Rx Undersize Frames : 0 Rx Total Drpd Idle Frames : 218719303953 Rx Dropped CDL Idle Frames : 218719301229 (having an SII of 255)

Last clearing of "show interface" counters never Hardware is data_enabled_port Switch#sh int wavepatch 1/0/0 Wavepatch1/0/0 is up, line protocol is up Receiver power level: -6.46 dBm

Optical threshold monitored for : Receive Power (in dBm) Threshold exceeded for : High Warning and High Alarm Low alarm value = -28.0 (default) Low Alarm Severity = major Low warning value = -26.0 (default) Low Warning Severity = not alarmed High alarm value = -8.0 (default) High Alarm Severity = major High warning value = -10.0 (default) High Warning Severity = not alarmed Hardware is passive_port

The following example shows how to display the configuration of a wavepatch interface:

Switch# show interfaces wavepatch 1/0/0 Wavepatch1/0/0 is up, line protocol is up Receiver power level: -6.46 dBm

Optical threshold monitored for : Receive Power (in dBm) Threshold exceeded for : High Warning and High Alarm Low alarm value = -28.0 (default) Low Alarm Severity = major Low warning value = -26.0 (default) Low Warning Severity = not alarmed High alarm value = -8.0 (default) High Alarm Severity = major High warning value = -10.0 (default) High Warning Severity = not alarmed Hardware is passive_port

Configuring 10-Gbps ITU Trunk Card Interfaces

To configure the 10-Gbps ITU trunk card interface, perform the following tasks, beginning in global configuration mode:

 
Command
Purpose

Step 1

Switch(config)# interface waveethernetphy slot/0

Switch(config-if)#

Selects the interface to configure and enters interface configuration mode.

Step 2

Switch(config-if)# [no] loopback [facility | terminal]

Enables or disables internal loopback for testing and defect isolation. (Optional)

Step 3

Switch(config-if)# [no] laser shutdown

Turns the laser on and off. (Optional)

Note The laser must warm up for 2 minutes before carrying traffic.

Step 4

Switch(config-if)# [no] cdl defect-indication force hop-endpoint

Enables or disables hop endpoint for in-band message channel defect indications when APS is not configured. (Optional)

Step 5

Switch(config-if)# no shutdown

Enables the interface.

Step 6

Switch(config-if)# exit

Switch(config)

Returns to global configuration mode.

Step 7

Switch(config)# interface wavepatch slot/0/0

Switch(config-if)#

Selects the interface to configure and enters interface configuration mode.

Step 8

Switch(config-if)# optical threshold power receive {low | high} {alarm | warning} value [severity {critical | major | minor | not alarmed | not reported}]

Specifies the optical power receive threshold value in units of 0.1 dBm. The default values are as follows:

Low alarm: -22 dBm

Low warning: -20 dBm

High warning: -10 dBm

High alarm: -8 dBm

Alarm severity: major

Warning severity: not alarmed

Step 9

Switch(config-if)# [no] shutdown

Enables or disables the interface.

Repeat Step 7 and Step 9 on wavepatch slot/0/1 for splitter 10-Gbps ITU trunk cards.


Caution Loopbacks on waveethernetphy interfaces disrupt service. Use this feature with care.

Note For configuration information for the ethernetdcc interface, see the "Configuring IP on Ethernetdcc Interfaces for the In-Band Message Channel" section on page 12-12.


Example

The following example shows how to configure 10-Gbps ITU trunk card waveethernetphy interfaces:

Switch(config)# interface waveethernetphy 10/0 Switch(config-if)# cdl defect-indication force hop-endpoint Switch(config-if)# no shutdown

Displaying the 10-Gbps ITU Trunk Card Interface Configuration

To display the configuration of 10-Gbps ITU trunk card interfaces, use the following EXEC command:

Command
Purpose

show interfaces {waveethernetphy slot/0[.subinterface] | wavepatch slot/0/port}

Displays the interface configuration.


Examples

The following example shows how to display the configuration of a waveethernetphy interface:

Switch# show interfaces waveethernetphy 10/0 WaveEthernetPhy10/0 is down, line protocol is down Channel:30 Frequency:195.7 Thz Wavelength:1531.90 nm Active Wavepatch :Wavepatch10/0/1 Splitter Protected :No Signal quality :Loss of lock Receive power level :-35.0 dBm Laser Bias Current :91 mA Laser Temperature :31.0 degree C Laser shut down :No Osc physical port :No Wavelength used for inband management:No Loopback not set

Configured threshold Group:None CDL HEC error count:0 Number of times SF threshold exceeded:0 Number of times SD threshold exceeded:0 CRC error count:0 Number of times SF threshold exceeded:0 Number of times SD threshold exceeded:0 Code violation and running disparity error count( 64b66b cvrd):0 Number of times SF threshold exceeded:0 Number of times SD threshold exceeded:0

Defect Indication Status :up Configured Node Behavior :None Current Node Behavior :Path Terminating Defect Indication Receive : None Defect Indication Transmit :BDI-H

Total Tx Frames Sent to N/W: 0 Tx Gen CDL Idle Frame: 1843017892

Rx Frames rcvd from N/W: 0 Rx CRC Errors: 0 Rx HEC Errors: 0 Rx XGMII Errors: 0 Rx IPG drpd pkts: 0 Rx Idle Packets : 0 Rx Oversize Frames : 0 Rx Undersize Frames : 0

Rx SII mismatch drpd data Frames : 0 Rx SII mismatch drpd idle Frames : 0

Last clearing of "show interface" counters never Hardware is data_enabled_port

The following example shows how to display the configuration of a waveethernetphy subinterface:

Switch# show interfaces waveethernetphy 10/0.1 WaveEthernetPhy10/0.1 is down, line protocol is down

Tx Frames Sent to N/W: 0 Tx HEC Errors: 0 Tx CRC Errors: 0 Tx QuadPHY sybl Errs: 55688870321 Tx Dropped Frames: 0 Tx Oversize Frames: 0 Tx Undersize Frames: 0 Tx Rcvd Idle Packets: 0

Rx Frames Sent to Clnt: 0 Rx FIFO full drpd pkts: 0 Rx Gen Idle pkt cnt: 0

Last clearing of "show interface" counters never Hardware is data_enabled_port

The following example shows how to display the configuration of a wavepatch interface:

Switch# show interfaces wavepatch 3/0/0 Wavepatch3/0/0 is up, line protocol is up Receiver power level:-9.86 dBm Optical threshold monitored for :Receive Power (in dBm) Threshold exceeded for :High Warning Low alarm value = -22.0 (default) Low Alarm Severity = major Low warning value = -20.0 (default) Low Warning Severity = not alarmed High alarm value = -8.0 (default) High Alarm Severity = major High warning value = -10.0 (default) High Warning Severity = not alarmed Hardware is passive_port

Configuring 10-Gbps Uplink Card Interfaces

To configure the 10-Gbps uplink card interface, perform the following tasks, beginning in global configuration mode:

 
Command
Purpose

Step 1

Switch(config)# interface tengigethernetphy slot/0

Switch(config-if)#

Selects the interface to configure and enters interface configuration mode.

Step 2

Switch(config-if)# [no] loopback [facility | terminal]

Enables or disables internal loopback for testing and defect isolation. (Optional)

Step 3

Switch(config-if)# [no] laser shutdown

Turns the laser on and off. (Optional)

Step 4

Switch(config-if)# [no] cdl defect-indication force hop-endpoint

Enables or disables hop endpoint for in-band message channel defect indications when APS is not configured. (Optional)

Step 5

Switch(config-if)# [no] shutdown

Enables or disables the interface.


Caution Loopbacks on tengigethernetphy interfaces disrupt service. Use this feature with care.

Note For configuration information for the ethernetdcc interface, see the "Configuring IP on Ethernetdcc Interfaces for the In-Band Message Channel" section on page 12-12.


Example

The following example shows how to configure 10-Gbps uplink card interfaces:

Switch(config)# interface tengigethernetphy 10/0 Switch(config-if)# cdl defect-indication force hop-endpoint Switch(config-if)# no shutdown

Displaying the 10-Gbps Uplink Card Interface Configuration

To display the configuration of 10-Gbps uplink card interfaces, use the following EXEC command:

Command
Purpose

show interfaces tengigethernetphy slot/0[.subinterface]

Displays the interface configuration.


Example

The following example shows how to display the configuration of an tengigethernetphy interface:

Switch# show interfaces tengigethernetphy 3/0 TenGigEthernetPhy3/0 is up, line protocol is up Signal quality :Good laser shut down :Off Osc physical port :No Loopback not set Wavelength used for inband management:No

Configured threshold Group:None CDL HEC error count:0 Number of times SF threshold exceeded:0 Number of times SD threshold exceeded:0 CRC error count:0 Number of times SF threshold exceeded:0 Number of times SD threshold exceeded:0 Code violation and running disparity error count( 64b66b cvrd):0 Number of times SF threshold exceeded:0 Number of times SD threshold exceeded:0

Defect Indication Status :up Configured Node Behavior :None Current Node Behavior :Path Terminating Defect Indication Receive : None Defect Indication Transmit : None

Total Tx Frames Sent to N/W: 48297 Tx Gen CDL Idle Frame: 2173636535

Rx Frames rcvd from N/W: 0 Rx CRC Errors: 0 Rx HEC Errors: 0 Rx XGMII Errors: 0 Rx IPG drpd pkts: 0 Rx Idle Packets : 1836560218 Rx Oversize Frames : 0 Rx Undersize Frames : 0

Rx SII mismatch drpd data Frames : 0 Rx SII mismatch drpd idle Frames : 1842816773

Last clearing of "show interface" counters never Hardware is data_enabled_port

The following example shows how to display the configuration of a tengigethernetphy subinterface:

Switch# show interfaces tengigethernetphy 3/0.4 TenGigEthernetPhy3/0.4 is up, line protocol is up

Tx Frames Sent to N/W: 0 Tx HEC Errors: 0 Tx CRC Errors: 0 Tx QuadPHY sybl Errs: 37831687439 Tx Dropped Frames: 0 Tx Oversize Frames: 0 Tx Undersize Frames: 0 Tx Rcvd Idle Packets: 0

Rx Frames Sent to Clnt: 0 Rx FIFO full drpd pkts: 0 Rx Gen Idle pkt cnt: 0

Last clearing of "show interface" counters never Hardware is data_enabled_port

About Cross Connections

The client signal follows a path of interface optical cross connections through the Cisco ONS 15530. Figure 7-1 shows an example of cross connections. Knowing the path of a signal through the shelf helps with system management and troubleshooting.

Figure 7-1 Optical Cross Connection Example

Configuring Cross Connections

The aggregated signal from the ESCON aggregation cards and the 8-port FC/GE aggregation cards passes through the switch fabric to the 2.5-Gbps ITU trunk card, 10-Gbps ITU trunk card, or the 10-Gbps uplink card. To establish a cross connection through the switch fabric, perform the following steps, beginning in global configuration mode:

 
Command
Purpose

Step 1

Switch(config)# connect interface1 interface2

Creates a cross connection between two interfaces through the switch fabric.

Example

The following example shows how to configure a cross connection between an ESCON aggregation card and a 2.5-Gbps ITU trunk card:

Switch(config)# connect portgroup 2/0/0 waveethernetphy 3/0

The following example shows how to configure a cross connection between an ESCON aggregation card and a 10-Gbps ITU trunk card:

Switch(config)# connect portgroup 2/0/0 waveethernetphy 3/0.1

The following example shows how to configure a cross connection between an ESCON aggregation card and a 10-Gbps uplink card:

Switch(config)# connect portgroup 2/0/0 tengigethernetphy 3/0.1

Displaying the Cross Connection Configuration

To display the cross connection configuration, use the following privileged EXEC command:

Command
Purpose

show connect [edge | intermediate [sort-channel | interface interface]]

Displays the signal cross connection configuration through the system.


Examples

The following example shows the cross connections within a system for an ESCON signal:

Switch# show connect Index Client Intf Trunk Intf Kind C2TStatus T2CliStatus ----- --------------- --------------- ----------- ---------- --------- 15 Port3/0/0 WaveE8/0.1 Provisioned Up Up

The following example shows the cross connections within a system for a transponder signal:

Switch# show connect intermediate client/ wave wave wdm wave client patch filter trk channel ------------ ------------ ------- ------ ----- ------- Trans7/0/0 Wave7/0 7/0/0* 0/0/0 0/0 25 7/0/1

About Alarm Thresholds

You can configure thresholds on the 2.5-Gbps ITU trunk card, 10-Gbps ITU trunk card, and 10-Gbps uplink interfaces that issue alarm messages to the system if the thresholds are exceeded.

Every second, the monitoring facility updates the counters that correspond to the alarm thresholds. When the signal degrades, or fails entirely, the system issues alarms to the console. These alarms can help isolate failures in the system and in the network.

You can configure more than one threshold list on an interface. The threshold lists cannot have overlapping counters so that only one counter is set for the interface. Also, the threshold list name cannot begin with the text string "default" because the it is reserved for use by the system.

Configuring Alarm Thresholds

To configure alarm thresholds on the 2.5-Gbps ITU trunk card, 10-Gbps ITU trunk card, and 10-Gbps uplink card interfaces, perform the following steps, beginning in global configuration mode:

 
Command
Purpose

Step 1

Switch(config)# threshold-list name

Switch(config-t-list)#

Creates or selects the threshold list to configure and enters threshold list configuration mode.

Note You cannot modify an existing threshold list if it is associated with an interface.

Step 2

Switch(config-t-list)# notification-throttle timer seconds

Configures the SNMP notification timer. The default value is 5 seconds. (Optional)

Step 3

Switch(config-t-list)# threshold name {cvrd | cdl hec | crc | sonet-sdh section cv | tx-crc} {failure | degrade} [index value]

Switch(config-threshold)#

Specifies a threshold type to modify and enters threshold configuration mode.

Step 4

Switch(config-threshold)# value rate value

Specifies the threshold rate value. This value is the negative power of 10 (10-n).

Step 5

Switch(config-threshold)# description text

Specifies a description of the threshold. The default value is the null string. (Optional)

Step 6

Switch(config-threshold)# exit

Switch(config-t-list)#

Returns to threshold list configuration mode.

Repeat Step 3 through Step 6 to configure more thresholds in the threshold list.

Step 7

Switch(config-t-list)# exit

Switch(config)#

Returns to global configuration mode.

Step 8

Switch(config)# interface interface

Switch(config-if)#

Selects the interface to configure and enters interface configuration mode.

Step 9

Switch(config-if)# threshold-group name

Configures the threshold list on the interface.

Table 7-1 lists the threshold error rates in errors per second.

Table 7-1 Threshold Values for Monitored Rates in Errors Per Second 

Rate
10-Gbps CVRD
10-Gbps CDL HEC
2.5-Gbps CVRD
2.5-Gbps CDL HEC

3

12,443,900

457901

19,968,416

1628

4

1,249,438

46765

2,055,776

166

5

124,944

4686

206,176

17

6

10,312

468

20,624

17

7

1031

47

2,064

17

8

103

4.7

208

17

9

10

0.47

24

17


Example

The following example shows how to create an alarm threshold list and configure that list for 10-Gbps ITU trunk card interfaces:

Switch# configure terminal Switch(config)# threshold-list cvrd-counters Switch(config-t-list)# threshold name cvrd degrade Switch(config-threshold)# value rate 9 Switch(config-threshold)# exit Switch(config-t-list)# threshold name cvrd failure Switch(config-threshold)# value rate 7 Switch(config-threshold)# exit Switch(config-t-list)# exit Switch(config)# interface waveethernetphy 10/0 Switch(config-if)# threshold-group cvrd-counters

Displaying the Alarm Threshold Configuration

To display the configuration of a threshold list and the threshold group for an interface, use the following EXEC commands:

Command
Purpose

show threshold-list [name]

Displays the threshold group configuration.

show interfaces {waveethernetphy slot/subcard | tengigethernetphy slot/subcard}

Displays the interface configuration.


Examples

The following example shows how to display the configuration of a threshold group:

Switch# show threshold-list cvrd-counters

Threshold List Name: cvrd-counters Notification throttle timer : 5 (in secs) Threshold name : CVRD Severity : Degrade Value : 10e-9 APS Trigger : Not set Threshold name : CVRD Severity : Failure Value : 10e-7 APS Trigger : Not set

The following example shows how to display the threshold group information for an interface:

Switch# show interfaces waveethernetphy 10/0 WaveEthernetPhy10/0 is administratively down, line protocol is down Channel: 3 Frequency: 192.3 Thz Wavelength: 1558.98 nm Active Wavepatch : Wavepatch10/0/0 Splitter Protected : No Receive power level : -8.38 dBm Laser shut down : No Osc physical port : No Wavelength used for inband management: No Loopback not set

Configured threshold Group(s): cvrd-counters Threshold monitored for: 64b66b cvrd SF set value: 10e-7 (1031 in 1 secs) SD set value: 10e-9 (10 in 1 secs) CDL HEC error count: 0 CRC error count: 0 Code violation and running disparity error count( 64b66b cvrd): 0 Number of times SF threshold exceeded: 0 Number of times SD threshold exceeded: 0

Defect Indication Status : down Configured Node Behavior : None Current Node Behavior : Path Terminating Defect Indication Receive : FDI-H FDI-E Defect Indication Transmit : FDI-H FDI-E

MTU Size: 10232 bytes

Total Tx Frames Sent to N/W: 0 Tx Gen CDL Idle Frame: 540367537118

Rx Frames rcvd from N/W: 0 Rx IPG drpd pkts: 0 Rx Idle Packets : 0 Rx Oversize Frames : 0 Rx Undersize Frames : 0

Rx SII mismatch drpd data Frames : 0 Rx SII mismatch drpd idle Frames : 0

Last clearing of "show interface" counters never Hardware is data_enabled_port

About Patch Connections

Because the mux/demux modules are passive devices, the Cisco ONS 15530 does not detect its optical patch connection configuration. For system management purposes, you must also configure the patch connection configuration using the CLI.

Configuring Patch Connections

To configure patch connections between link cards within the same shelf, use the following global configuration commands:

Command
Purpose

patch wavepatch slot1/subcard1/port1 filter slot2/subcard2/port2

or

patch filter slot1/subcard1/port1 wavepatch slot2/subcard2/port2

Configures the patch connection between a 2.5-Gbps ITU trunk card or 10-Gbps ITU trunk card and an OADM module.

patch thru slot/subcard1 thru slot/subcard2

Configures the patch connection between two OADM modules.

patch wave slot/subcard oscfilter slot/subcard

or

patch oscfilter slot/subcard wave slot/subcard

Configures the patch connection between the wave interface on the OSC module and the oscfilter interface on the OADM module. This is only required if an OSC module is present.



Note If you correctly patch your cards, patch command configuration is not necessary for the signal to pass from the client to the trunk fiber.


Example

The following example shows how to configure the patch connections between line cards in a shelf with two OSC cards in slot  4, two OADM modules with OSC in slot  0, and a splitter 2.5-Gbps ITU trunk card or 10-Gbps ITU trunk card in slot 3:

Switch# configure terminal Switch(config)# patch thru 0/0 thru 0/1 Switch(config)# patch wave 4/0 oscfilter 0/0 Switch(config)# patch wave 4/1 oscfilter 0/1 Switch(config)# patch wavepatch 3/0/0 filter 0/0/1 Switch(config)# patch wavepatch 3/0/1 filter 0/1/1