Cisco ONS 15530 TL1 Commands
Cisco IOS Release 12.1(12c)EV1
1   Alarms and Faults
2   Automatic Protection Switching
3   Cisco Discovery Protocol
4   Cross Connections
5   Generic Network Element Configuration
6   Interface Configuration (Escon)
7   Interface Configuration (Transparent, Wave, Wavepatch, Etherdcc, and VOA)
8   Interface Configuration (Tengigetherphy and Waveetherphy)
9   IP Configuration and Static Routes
10   Memory Management
11   Network Time Protocol
12   Optical Supervisory Channel Protocol
13   Optical Parameter Monitoring
14   Patch Configuration
15   Redundancy
16   Security
17   Threshold List Configuration
18   Topology Neighbor Configuration
19   Access Identifiers
20   Command Components
21   Where to Go Next

Quick Reference

Cisco ONS 15530 TL1 Commands


Cisco IOS Release 12.1(12c)EV1

This guide lists TL1 commands and autonomous messages by category. It includes basic descriptions and input and output formats supported by the Cisco ONS 15530 for Cisco IOS Release 12.1(12c)EV1.

TL1 commands conform to the following syntax:

a:b:c:d:e: ...z;

where:

The TID, AID, and CTAG route and control the TL1 command.

Other parameters provide additional information required to complete the action requested by the command.

1   Alarms and Faults

Table 1   Alarms and Faults

ALW-MSG-ALL

ALW-MSG-ALL:[<tid>]::<ctag>;

Allows the transmission of all autonomous messages.

INH-MSG-ALL

INH-MSG-ALL:[<tid>]::<ctag>;

Disallows transmission of autonomous messages.

RTRV-ALM-ALL

RTRV-ALM-ALL:[<tid>]:[<aid>]:<ctag>::[<ntfcncde>];

Retrieves the alarms for a specified component.

Output format:

      SID DATE TIME
M CTAG COMPLD
      "<aid>:<severity>,<alarm>,SA,,,,,:\"<text>\""

;

RTRV-ALM-ENV

RTRV-ALM-ENV:[<tid>]:[<aid>]:<ctag>::[<ntfcncde>];

Retrieves the environmental alarms on the system.

Output format:

      SID DATE TIME
M CTAG COMPLD
      ":<severity>,<alarm>,,,\"<text>\""
;

RTRV-COND-ALL

RTRV-COND-ALL:[<tid>]:[<aid>]:<ctag>;

Retrieves the current standing conditions associated with a specified component.

Output format:

      SID DATE TIME
M CTAG COMPLD
      "<aid>,<encap>:<severity>,<condtype>,NSA,,,,,\"<text>\""
;

RTRV-LOG

RTRV-LOG:[<tid>]::<ctag>::[<lognm>];

Retrieves the alarm log on the system.

Output format:

      SID DATE TIME
M CTAG COMPLD
"<text>"
;

/* RTRV-LOG */

2   Automatic Protection Switching

Table 2   Automatic Protection Switching

ENT-FFP-OCH

ENT-FFP-OCH:[<tid>]:<wkg_aid>,<prot_aid>:<ctag>:::[PROTID=<protid>],[PSDIRN=<psdirn>],
[RVRTV=<rvrtv>],[RVRTM=<rvrtm>],[ENSWOTM=<enswotm>],[YCABLE=<ycable>],
[MSGCH=<msgch>],[MSGHOLDTM=<msgholdtm>],[MSGHOLDCOUNT=<msgholdcount>],
[MSGMAXINTVTM=<msgmaxintvtm>],[FENDPROTID=<fendprotid>],
[FENDIPADDR=<fendipaddr>]: [<pst>];

Configures splitter protection and line card protection.

ED-FFP-OCH

ED-FFP-OCH:[<tid>]:<wkg_aid>,<prot_aid>:<ctag>:::[PSDIRN=<psdirn>],[RVRTV=<rvrtv>],
[RVRTM=<rvrtm>],[YCABLE=<ycable>],[ENSWOTM=<enswotm>],[MSGCH=<msgch>],
[MSGHOLDTM=<msgholdtm>],[MSGHOLDCOUNT=<msgholdcount>],
[MSGMAXINTVTM=<msgmaxintvtm>],[FENDPROTID=<fendprotid>],
[FENDIPADDR=<fendipaddr>]:[<pst>];

Edits the attributes associated with an APS group and puts the APS group in-service or out-of-service.

RTRV-FFP-OCH

RTRV-FFP-OCH:[<tid>]:[<wkg_aid>],[<prot_aid>]:<ctag>:::[PROTID=<protid>];

Retrieves the APS group information.

Output format:

      SID DATE TIME
M CTAG COMPLD
      "<wkg_aid>,<prot_aid>:ACTIVE=<active>,STANDBY=<standby>,PROTID=<protid>,
        PSDIRN=<psdirn>,RVRTV=<rvrtv>,RVRTM=<rvrtm>,ENSWOTM=<enswotm>,
        SRCHUPMIN=<srchupmin>,SRCHUPMAX=<srchupmax>,FENDDIRN=<fenddirn>,
        MSGCH=<msgch>,MSGCHCUR=<msgchcur>,MSGHOLDTM=<msgholdtm>,
        MSGCHST=<msgchst>,MSGHOLDCOUNT=<msgholdcount>,
        MSGMAXTM=<msgmaxtm>:<pst>"
;

DLT-FFP-OCH

DLT-FFP-OCH:[<tid>]:<wkg_aid>,<prot_aid>:<ctag>;

Deletes an APS group.

OPR-PROTNSW-OCH

OPR-PROTNSW-OCH:[<tid>]:<aid>:<ctag>::<sc>;

Requests a protection switchover or lockout.

RLS-PROTNSW-OCH

RLS-PROTNSW-OCH:[<tid>]:<aid>:<ctag>::;

Clears a protection switchover or lockout request.

3   Cisco Discovery Protocol

Table 3   Cisco Discovery Protocol

ED-NE-CDP

ED-NE-CDP:[<tid>]::<ctag>:::[CDP=<cdp>],[UPDATETIME=<updatetime>],
[HOLDTIME=<holdtime>],[SENDVER=<sendver>];

Changes global Cisco Discovery Protocol (CDP) attributes.

RST-NE-CDP

RST-NE-CDP:[<tid>]::<ctag>;

Restores all global CDP attribute settings to the default values.

RTRV-NE-CDP

RTRV-NE-CDP:[<tid>]::<ctag>;

Retrieves the global CDP information.

Output format:

      SID DATE TIME
M CTAG COMPLD
      ":CDP=<cdp>,UPDATETIME=<updatetime>,HOLDTIME=<holdtime>,SENDVER=<sendver>"
;

RTRV-CDPNBR

RTRV-CDPNBR:[<tid>]:[<aid>]:<ctag>;

Retrieves the neighbor information discovered by CDP on a specific port or on all ports on the system.

Output format:

      SID DATE TIME
M CTAG COMPLD
      "<aid>:NBRNAME=<nbrname>,NBRPORT=<nbrport>,CAPABILITY=<capability>,
        TTL=<ttl>"
;

4   Cross Connections

Table 4   Cross Connections

ENT-CRS-OCH

ENT-CRS-OCH:[<tid>]:<from_aid>,<to_aid>:<ctag>::[<cct>];

Creates a cross connection between two interfaces across the switch fabric.

DLT-CRS-OCH

DLT-CRS-OCH:[<tid>]:<from_aid>,<to_aid>:<ctag>;

Deletes a cross connection.

RTRV-CRS-OCH

RTRV-CRS-OCH:[<tid>]:<from_aid>,<to_aid>:<ctag>;

Retrieves the cross connection information between two interfaces.

Output format:

      SID DATE TIME
M CTAG COMPLD
      "<from_aid>,<to_aid>:<dirn>"
;

RTRV-CRS-ALL

RTRV-CRS-ALL:[<tid>]::<ctag>;

Retrieves the cross connection information for the system.

Output format:

      SID DATE TIME
M CTAG COMPLD
      "<from_aid>,<to_aid>:<dirn>"
;

5   Generic Network Element Configuration

Table 5   Generic Network Element Configuration

ED-NE-GEN

ED-NE-GEN:[<tid>]::<ctag>:::[CFGREG=<cfgreg>];

Configures the generic network element (NE) configuration information, such as the software configuration register value.

RTRV-NE-GEN

RTRV-NE-GEN:[<tid>]::<ctag>;

Retrieves the generic NE information.

Output format:

      SID DATE TIME
M CTAG COMPLD
      ":CURCFGREG=<curcfgreg>,NEWCFGREG=<newcfgreg>,SWVER=<swver>,
        SWNAME=<swname>,SYSFILE=<sysfile>,CMPLTIME=<cmpltime>,CMPLBY=<cmplby>"
;

INIT-SYS

INIT-SYS:[<tid>]:<aid>:<ctag>::;

Initializes or resets a CPU switch module.

SET-SID

SET-SID:[<tid>]::<ctag>::<sid>;

Changes the system identification code to the specified value.

RTRV-HDR

RTRV-HDR:[<tid>]::<ctag>;

Retrieves the system header information.

Output format:

      SID DATE TIME
M CTAG COMPLD
;

ED-DAT

ED-DAT:[<tid>]::<ctag>::[<date>],[<time>];

Edits the date and time on the system.

RTRV-TOD

RTRV-TOD:[<tid>]::<ctag>;

Retrieves the system time-of-date information.

Output format:

      SID DATE TIME
M CTAG COMPLD
      "<year>,<month>,<day>,<hour>,<minute>,<second>.<thousandths-of-second>,<timezone>"
;

6   Interface Configuration (Escon)

Table 6   Interface Configuration (Escon)

ED-ESCON

ED-ESCON:[<tid>]:<aid>:<ctag>:::[RXFLOWID=<rxflowid>],[TXFLOWID=<txflowid>],
[THRLISTNAME=<thrlistname>]:[<pst>];

Configures parameters for an escon interface.

RTRV-ESCON

RTRV-ESCON:[<tid>]:[<aid>]:<ctag>;

Retrieves the escon interface configuration information.

      SID DATE TIME
M CTAG COMPLD
      "<aid>:RXFLOWID=<rxflowid>,TXFLOWID=<txflowid>,THRLISTNAME=<thrlistname>,
        RXMAXFLOWID=<rxmaxflowid>,TXMAXFLOWID=<txmaxflowid>:<pst>"
;

RTRV-PM-ESCON

RTRV-PM-ESCON:[<tid>]:[<aid>]:<ctag>::[<montype>],,,[<tmper>];

Retrieves the performance monitoring parameters for an escon interface.

Output format:

      SID DATE TIME
M CTAG COMPLD
      "<aid>:<montype>,<count>,COMPL,,,<interval>"
;

INIT-REG-ESCON

INIT-REG-ESCON:[<tid>]:<aid>:<ctag>;

Clears the counters associated with an escon interface.

7   Interface Configuration (Transparent, Wave, Wavepatch, Etherdcc, and VOA)

Table 7   Interface Configuration (Transparent, Wave, Wavepatch, Etherdcc, and VOA)

ED-OCH

ED-OCH:[<tid>]:<aid>:<ctag>:::[ENCAP=<encap>],[RATE=<rate>],[FLC=<flc>],[LSC=<lsc>],
[OFC=<ofc>],[THRLISTNAME=<thrlistname>],[CDP=<cdp>],[LASERFREQ=<laserfreq>]:[<pst>];

Configures protocol encapsulation, clock rate, forward laser control, Open Fiber Control (OFC), threshold lists, Cisco Discovery Protocol (CDP), and interface state for a transparent interface.

Configures forward laser control, laser safety control, threshold lists, laser frequency, and interface state for a wave interface.

Configures the interface state for a wavepatch interface.

Configures the CDP and interface state for an etherdcc interface.

RTRV-OCH

RTRV-OCH:[<tid>]:[<aid>]:<ctag>;

Retrieves the interface configuration information.

Output format for a transparent interface:

      SID DATE TIME
M CTAG COMPLD
      "<aid>:ENCAP=<encap>,RATE=<rate>,THRLISTNAME=<thrlistname>,FLC=<flc>,
        OFC=<ofc>,CDP=<cdp>,LPBKTYPE=<lpbktype>:<pst>"
;

Output format for a wave interface:

      SID DATE TIME
M CTAG COMPLD
      "<aid>:THRLISTNAME=<thrlistname>,FLC=<flc>,LSC=<lsc>,LASERFREQ=<laserfreq>,
        LPBKTYPE=<lpbktype>:<pst>"
;

SET-PMMODE-OCH

SET-PMMODE-OCH:[<tid>]:<aid>:<ctag>::,,<pmstate>;

Enables and disables the performance monitoring for a transparent interface.

RTRV-PMMODE-OCH

RTRV-PMMODE-OCH:[<tid>]:[<aid>]:<ctag>;

Retrieves the performance monitoring configuration for a transparent interface.

Output format:

      SID DATE TIME
M CTAG COMPLD
      "<aid>:,,<pmmode>"
;

INIT-REG-OCH

INIT-REG-OCH:[<tid>]:[<aid>]:<ctag>;

Clears the counters associated with a transparent or wave interface.

OPR-LPBK-OCH

OPR-LPBK-OCH:[<tid>]:<aid>:<ctag>::,,,<lpbktype>;

Operates a loopback on a transparent or wave interface.

RLS-LPBK-OCH

RLS-LPBK-OCH:[<tid>]:<aid>:<ctag>::,,,<lpbktype>;

Releases a loopback on a transparent or wave interface.

SET-VOA

SET-VOA:[<tid>]:<aid>:<ctag>:::[ATTENMODE=<attenmode>],[DESATTEN=<desatten>],
[DESPOWER=<despower>];

Configures the attenuation or the desired power level on the variable optical attenuator (VOA) module interfaces.

RTRV-VOA

RTRV-VOA:[<tid>]:[<aid>]:<ctag>;

Retrieves the attenuation or power level configured for VOA module interfaces.

Output format:

      SID DATE TIME
M CTAG COMPLD
      "<aid>:ATTENMODE=<attenmode>,DESPOWER=<despower>,CURATTEN=<curatten>,
        CURPOWER=<curpower>,MINATTEN=<minatten>,MAXATTEN=<maxatten>:<pst>"
;

RTRV-PM-ENCAP

RTRV-PM-ENCAP:[<tid>]:[<aid>]:<ctag>::[<montype>],,,,[<tmper>],[<mondat>],[<montm>];

Retrieves the performance monitoring parameters related to error counters for transparent or wave interfaces.

Output format:

      SID DATE TIME
M CTAG COMPLD
      "<aid>:<error>,<count>,COMPL,,,<interval>,,"
;

8   Interface Configuration (Tengigetherphy and Waveetherphy)

Table 8   Interface Configuration (Tengigetherphy and Waveetherphy)

ED-GBE10

ED-GBE10:[<tid>]:<aid>:<ctag>:::[CDL=Y],[FLC=Y],[FRCENDHOP=<frcendhop>],
[THRLISTNAME=<thrlistname>]:[<pst>];

Configures the in-band message channel, forward laser control, forced end-of-hop, and alarm threshold lists on a tengigetherphy or waveetherphy interface.

RTRV-GBE10

RTRV-GBE10:[<tid>]:[<aid>]:<ctag>;

Retrieves the information for a tengigetherphy and waveetherphy interface.

Output format:

     SID DATE TIME
M CTAG COMPLD
     "<aid>:THRLISTNAME=<thrlistname>,FRCENDHOP=<frcendhop>,
       NODEBEHAVIOUR=<nodebehaviour>,LPBKTYPE=<lpbktype>:<pst>"
;

RTRV-PM-GBE10

RTRV-PM-GBE10:[<tid>]:[<aid>]:<ctag>::[<montype>],,,,[<tmper>],[<mondat>],[<montm>];

Retrieves the performance monitoring parameters for tengigetherphy and waveetherphy interfaces.

Output format:

     SID DATE TIME
M CTAG COMPLD
     "<aid>:<error>,<count>,COMPL,,,,<interval>"
;

INIT-REG-GBE10

INIT-REG-GBE10:[<tid>]:<aid>:<ctag>;

Clears the counters associated with a tengigetherphy or waveetherphy interface.

OPR-LPBK-GBE10

OPR-LPBK-GBE10:[<tid>]:<aid>:<ctag>::,,,<lpbktype>;

Operates a loopback on a tengigetherphy or waveetherphy interface.

RLS-LPBK-GBE10

RLS-LPBK-GBE10:[<tid>]:<aid>:<ctag>::,,,<lpbktype>;

Releases a loopback on a tengigetherphy or waveetherphy interface.

9   IP Configuration and Static Routes

Table 9   IP Configuration and Static Routes

ENT-IP

ENT-IP:[<tid>]:<aid>:<ctag>:::IPADDRTYPE=<ipaddrtype>,[IPADDR=<ipaddr>],
[IPMASK=<ipmask>],[IPUNIF=<ipunif>];

Configures a network management Ethernet (NME) port, an OSC wave interface, an etherdcc interface, or a loopback interface.

ED-IP

ED-IP:[<tid>]:<aid>:<ctag>:::IPADDR=<ipaddr>,IPMASK=<ipmask>;

Edits the IP address and subnet mask on an NME port, an OSC wave interface, an etherdcc interface, or a loopback interface.

DLT-IP

DLT-IP:[<tid>]:<aid>:<ctag>;

Deletes the IP configuration on an NME port, an OSC wave interface, an etherdcc interface, or a loopback interface.

RTRV-IP

RTRV-IP:[<tid>]:[<aid>]:<ctag>;

Retrieves the IP configuration information.

Output format:

      SID DATE TIME
M CTAG COMPLD
      "<aid>:IPADDRTYPE=<ipaddrtype>,IPADDR=<ipaddr>,IPMASK=<ipmask>"
;

ENT-IPROUTE-STATIC

ENT-IPROUTE-STATIC:[<tid>]::<ctag>:::PREFIXADDR=<prefixaddr>,
PREFIXMASK=<prefixmask>,[ROUTEIF=<routeif>],[ROUTEADDR=<routeaddr>];

Creates static IP routes.

DLT-IPROUTE-STATIC

DLT-IPROUTE-STATIC:[<tid>]::<ctag>:::PREFIXADDR=<prefixaddr>,
PREFIXMASK=<prefixmask>,[ROUTEIF=<routeif>],[ROUTEADDR=<routeaddr>];

Deletes static IP routes.

RTRV-IPROUTE

RTRV-IPROUTE:[<tid>]::<ctag>:::ROUTETYPE=<routetype>;

Retrieves the IP routing information.

Output format:

      SID DATE TIME
M CTAG COMPLD
      ":ROUTETYPE=<routetype>,PREFIXADDR=<prefixaddr>,PREFIXMASK=<prefixmask>,
        ROUTEIF=<routeif>"
;

INIT-REG-ETH

INIT-REG-ETH:[<tid>]:<aid>:<ctag>;

Clear the counters associated with an NME interface.

10   Memory Management

Table 10   Memory Management

CPY-MEM

CPY-MEM:[<tid>]::<ctag>::<frommem>,[<fromdev>],<tomem>,[<todev>]:
[CMDMODE=<cmdmode>];

Copies a file from one memory location to another.

DLT-MEM

DLT-MEM:[<tid>]:<aid>:<ctag>:::FILENAME=<filename>;

Deletes a file from BOOTFLASH, DISK-0, SBY-BOOTFLASH, or SBY-DISK-0.

RST-MEM

RST-MEM:[<tid>]:<aid>:<ctag>:::INDEX=<index>;

Recovers a file that was previously deleted from BOOTFLASH or SBY-BOOTFLASH memory, but not erased, using the DLT-MEM command.

SQUEEZE-MEM

SQUEEZE-MEM:[<tid>]:<aid>:<ctag>;

Permanently deletes files from and defragments BOOTFLASH or SBY-BOOTFLASH.

FORMAT-MEM

FORMAT-MEM:[<tid>]:<aid>:<ctag>:::[CMDMODE=<mode>];

Permanently formats BOOTFLASH or SBY-BOOTFLASH.

RTRV-MEM

RTRV-MEM:[<tid>]:[<aid>]:<ctag>:::[FILENAME=<file>],[STATUS=<status>];

Retrieves the information on all files on a Flash memory device.

Output format:

      SID DATE TIME
M CTAG COMPLD
      "<aid>:INDEX=<index>,ACCESS=<access>,SIZE=<size>,DATE=<date>,TIME=<time>,
        FILENAME=<filename>,STATUS=<status>"
;

RTRV-FILE

RTRV-FILE:[<tid>]::<ctag>:::FILENAME=<filename>],[LINES=<lines>],[OFFSET=<offset>];

Retrieves the contents of the configuration files.

Output format:

      SID DATE TIME
M CTAG COMPLD
      "<text>"
;

11   Network Time Protocol

Table 11   Network Time Protocol

SET-NTP

SET-NTP:[<tid>]::<ctag>:::[MASTER=<master>],[MSTRATUM=<mstratum>],
[MAXASSOC=<maxassoc>],[CLKPERIOD=<clkperiod>],[UPDCAL=<updcal>];

Configures the NTP attributes for the entire system.

ENT-NTPASSOC

ENT-NTPASSOC:[<tid>]::<ctag>:::ASSOCTYPE=<assoctype>,ASSOCIPADDR=<associpaddr>;

Configures the NTP associations for synchronizing system clocks over the network.

DLT-NTPASSOC

DLT-NTPASSOC:[<tid>]::<ctag>:::ASSOCTYPE=<assoctype>,ASSOCIPADDR=<associpaddr>;

Deletes an existing NTP association.

RTRV-NTPASSOC

RTRV-NTPASSOC:[<tid>]::<ctag>;

Retrieves the NTP parameters for an association.

Output format:

      SID DATE TIME
M CTAG COMPLD
      "ASSOCTYPE=<assoctype>,ASSOCIPADDR=<associpaddr>,
        ASSOCSTRATUM=<assocstratum>,ASSOCREFID=<assocrefid>,ASSOCPOLL=<assocpoll>,
        ASSOCREACH=<assocreach>,ASSOCDELAY=<assocdelay>,ASSOCOFFSET=<assocoffset>,
        ASSOCDISP=<assocdisp>"
;

RTRV-NTP

RTRV-NTP:[<tid>]::<ctag>;

Retrieves the NTP information for the system.

Output format:

      SID DATE TIME
M CTAG COMPLD
      "SYNCSTATE=<syncstate>,STRATUM=<stratum>,REFIPADDR=<refipaddr>,
        NOMFREQ=<nomfreq>,ACTFREQ=<actfreq>,PRECISION=<precision>,
        REFTIME=<reftime>,CLKOFFSET=<clkoffset>,ROOTDELAY=<rootdelay>,
        ROOTDISP=<rootdisp>,PEERDISP=<peerdisp>"
;

12   Optical Supervisory Channel Protocol

Table 12   Optical Supervisory Channel Protocol

ED-NE-OSCP

ED-NE-OSCP:[<tid>]::<ctag>:::[HELLOINTV=<hellointv>],[HELLOHLDWN=<hellohldwn>],
[INACTFCTR=<factor>];

Configures the OSCP.

RTRV-NE-OSCP

RTRV-NE-OSCP:[<tid>]::<ctag>;

Retrieves the configuration for OSCP.

Output format:

      SID DATE TIME
M CTAG COMPLD
      "HELLOINTV=<hellointv>,HELLOHLDWN=<hellohldwn>,INACTFCTR=<inactfctr>"
;

13   Optical Parameter Monitoring

Table 13   Optical Parameter Monitoring

RTRV-PM-rr

RTRV-PM-rr:[<tid>]:[<aid>]:<ctag>::[<montype>],[<monlev>],,[<dirn>],[<tmper>],[<mondat>],
[<montm>];

where rr can be OCH or WDM.

Retrieves the performance monitoring information for wavepatch and VOA module interfaces.

Output format:

      SID DATE TIME
M CTAG COMPLD
      "<aid>:<montype>,<value>,COMPL,,<dirn>,<interval>,<date>,<time>"
;

SET-TH-rr

SET-TH-rr:[<tid>]:[<aid>]:<ctag>::[<montype>],[<thlev>],,[<dirn>];

where rr can be OCH or WDM.

Configures a threshold level on the monitored optical parameters for wavepatch, waveetherphy, and VOA module interfaces.

SET-ATTR-rr

SET-ATTR-rr:[<tid>]:<aid>:<ctag>::[<ntfcncde>],[<condtype>],,[<dirn>];

where rr can be OCH or WDM.

Configures the severity associated with the thresholds configured using the SET-TH-rr command.

RTRV-TH-rr

RTRV-TH-rr:[<tid>]:[<aid>]:<ctag>::[<montype>];

where rr can be OCH or WDM.

Retrieves the optical threshold values configured on the wavepatch and VOA module interfaces.

Output format:

      SID DATE TIME
M CTAG COMPLD
      "<aid>:<montype>,,<dirn>,<value>"
;

RTRV-ATTR-rr

RTRV-ATTR-rr:[<tid>]:[<aid>]:<ctag>::[<ntfcncde>],[<condtype>],,[<dirn>];

where rr can be OCH or WDM.

Retrieves the severity levels assigned to the threshold values configured on the wavepatch and VOA module interfaces.

Output format:

      SID DATE TIME
M CTAG COMPLD
      "<aid>:<severity>,<condtype>,,<dirn>"
;

14   Patch Configuration

Table 14   Patch Configuration

ENT-PATCH

ENT-PATCH:[<tid>]:<from_aid>,<to_aid>:<ctag>::[<ctype>];

Configures a patch connection between two interfaces.

DLT-PATCH

DLT-PATCH:[<tid>]:<from_aid>,<to_aid>:<ctag>;

Deletes a patch configuration.

RTRV-PATCH

RTRV-PATCH:[<tid>]:[<from_aid>],[<to_aid>]:<ctag>;

Retrieves the patch configuration.

Output format:

      SID DATE TIME
M CTAG COMPLD
      "<from_aid>,<to_aid>:<dirn>"
;

15   Redundancy

Table 15   Redundancy

SW-DX-EQPT

SW-DX-EQPT:[<tid>]:<aid>:<ctag>::[<mode>];

Switches activity from the active CPU switch module to the standby CPU switch module.

ALW-SWDX-EQPT

ALW-SWDX-EQPT:[<tid>]:<aid>:<ctag>;

Enables switchovers and configuration synchronization between the active and standby CPU switch modules.

INH-SWDX-EQPT

INH-SWDX-EQPT:[<tid>]:<aid>:<ctag>;

Disables switchovers and configuration synchronization between the active and standby CPU switch modules.

RTRV-EQPT

RTRV-EQPT:[<tid>]:[<aid>]:<ctag>;

Retrieves the redundancy configuration.

Output format for CPU switch modules:

      SID DATE TIME
M CTAG COMPLD
      "<aid>:<clei>:PN=<pn>,SN=<sn>,OPN=<opn>,HWVER=<hwver>,SWVER=<swver>,
        FWVER=<fwver>,BOOTLDR=<bootldr>,ROMMONVER=<rommonver>,
        HWREDSTATE=<hwredstate>,SWREDSTATE=<swredstate>,,:<pst>,<sst>,<sst>"
;

Output format for transponder line cards:

      SID DATE TIME
M CTAG COMPLD
      "<aid>:<clei>:PN=<pn>,SN=<sn>,OPN=<opn>,HWVER=<hwver>,,FSWVER=<fwver>,,,,,
        LASERFREQLOW=<laserfreqlow>,LASERFREQHIGH=<laserfreqhigh>:<pst>,<sst>,<sst>"
;

RTRV-PM-EQPT

RTRV-PM-EQPT:[<tid>]:[<aid>]:<ctag>;

Retrieves the performance monitoring data for CPU switch modules.

Output format:

      SID DATE TIME
M CTAG COMPLD
      "<aid>:<montype>,<count>,,,,<time>"
;

16   Security

Table 16   Security

ENT-USER-SECU

ENT-USER-SECU:[<tid>]:<uid>:<ctag>::<pid>,,<uap>;

Create a user ID and sets the security parameters.

ED-USER-SECU

ED-USER-SECU:[<tid>]:<uid>:<ctag>::<newuid>,<newpid>,,<uap>;

Edits the user ID, password, or privilege level associated with a user ID.

DLT-USER-SECU

DLT-USER-SECU:[<tid>]:<uid>:<ctag>;

Deletes an existing user ID.

RTRV-USER-SECU

RTRV-USER-SECU:[<tid>]:<uid>:<ctag>;

Retrieves the security parameters associated with a user ID, except for the password.

Output format:

      SID DATE TIME
M CTAG COMPLD
      "<uid>:,<security>:"
;

ACT-USER

ACT-USER:[<tid>]:<uid>:<ctag>::<pid>;

Logs a user on to the system.

CANC-USER

CANC-USER:[<tid>]:<uid>:<ctag>;

Logs a user off the system.

ED-PID

ED-PID:[<tid>]:<uid>:<ctag>::<oldpid>,<newpid>;

Allows users to edit their own password.

17   Threshold List Configuration

Table 17   Threshold List Configuration

ENT-THR-OCH

ENT-THR-OCH:[<tid>]:<THRLISTNAME>:<ctag>:::ERRTYPE=<errtype>,THRTYPE=<thrtype>,
VALUE=<value>,[TRGAPS=<trgaps>],[INDEX=<index>],[DESC=<desc>];

Sets the thresholds for errors monitored for an interface.

ED-THR-OCH

ED-THR-OCH:[<tid>]:<THRLISTNAME>:<ctag>:::ERRTYPE=<errtype>,THRTYPE=<thrtype>,
[VALUE=<value>],[TRGAPS=<trgaps>],[DESC=<desc>];

Edits the parameters for an existing threshold in a threshold list.

DLT-THR-OCH

DLT-THR-OCH:[<tid>]:<THRLISTNAME>:<ctag>:::[ERRTYPE=<errtype>,
THRTYPE=<thrtype>];

Deletes an entire threshold list or thresholds within a list.

RTRV-THR-OCH

RTRV-THR-OCH:[<tid>]:[<thrlistname>]:<ctag>:::[ERRTYPE=<errtype>,THRTYPE=<thrtype>];

Retrieves the threshold information, either the complete threshold list or specific thresholds within the list.

Output format:

      SID DATE TIME
M CTAG COMPLD
      "<thrlistname>:ERRTYPE=<errtype>,THRTYPE=<thrtype>,VALUE=<value>,
        INDEX=<index>,TRGAPS=<trgaps>,DESCR=<descr>"
;

18   Topology Neighbor Configuration

Table 18   Topology Neighbor Configuration

ENT-NBR

ENT-NBR:[<tid>]:<aid>:<ctag>:::DSCVRY=<dscvry>,[LINKDIRN=<linkdirn>],
[NBRNAME=<nbrname>],[NBRPORT=<nbrport>],[NBRAGENTIP=<nbragentip>],
[PRXYPORT=<prxyport>;

Configures a physical neighbor on an interface.

DLT-NBR

DLT-NBR:[<tid>]:<aid>:<ctag>:::[LINKDIRN=<linkdirn>];

Deletes a neighbor entry for an interface or disables learning through CDP on an interface.

RTRV-NBR

RTRV-NBR:[<tid>]:[<aid>]:<ctag>;

Retrieves the physical neighbor information.

Output format:

      SID DATE TIME
M CTAG COMPLD
      "<aid>:DSCVRY=<dscrvy>,LINKDIRN=<linkdirn>,NBRNAME=<nbrname>,
        NBRPORT=<nbrport>,NBRAGENTIP=<nbragentip>"
;

19   Access Identifiers

Table 19   Access Identifiers

Slots

SLOT-[0-10]
SLOT-[5-6]
SLOT-[0-4,7-10]-[0-1]

Interfaces

TRANSPARENT-[1-4,7-10]-0-0
WAVE-[1-4,7-10]-[0-1]
WAVEPATCH-[1-4,7-10]-0-[0-1]
ESCON-[1-4,7-10]-0-[0-9]
PORTGROUP-[1-4,7-10]-0-0
VOAIN-[1-4,7-10]-[0-1]-[0-1]
VOAOUT-[1-4,7-10]-[0-1]-[0-1]
VOAFILTERIN-[1-4,7-10]-[0-1]-0-[1-2]
VOAFILTEROUT-[1-4,7-10]-[0-1]-0-[1-2]
VOABYPASSIN-[1-4,7-10]-[0-1]-0
VOABYPASSOUT-[1-4,7-10]-[0-1]-0
WAVEETHERPHY-[1-4,7-10]-0
WAVEETHERPHY-[1-4,7-10]-0-[1-4]
TENGIGETHERPHY-[1-4,7-10]-0
TENGIGETHERPHY-[1-4,7-10]-0-0
FILTER-0-[0-1]-[0-3]
OSCFILTER-0-[0-1]
THRU-0-[0-1]
WDM-0-[0-1]
ETHERDCC-[1-4,7-10]-0-0
FE-0
FE-SBY-0
LOOPBACK-[0-255]

Memory

BOOTFLASH
SBY-BOOTFLASH
DISK-[0-1]
SBY-DISK-[0-1]
PCMCIA-[0-1]
SBY-PCMCIA-[0-1]

20   Command Components

Table 20   Command Components

Component  Values 

ASSOCTYPE

PEER
SERVER

ATTENMODE

AUTO
MAN

CDP

N
Y

CLKPERIOD

0 TO 4294967295 clock ticks (2-32 second)

CMDMODE

FRCD
NORMAL

CONTYPE

ESS
SEFS-S
SESS
CVRD
CDLHEC

CTYPE

1WAY
2WAY

DESATTEN

17 to 300 tenths of dB

DESPOWER

-50 to 250 tenths of dBm

DSCRVY

CDP
MANUAL

ENCAP

ESCON
FC-1G
FC-2G
FDDI
FE
FICON
GIGE
OC3
OC12
OC48
STM1
STM4
STM16
SYSPLEX-CLO
SYSPLEX-ETR
SYSPLEX-ISC-COMP
SYSPLEX-ISC-PEER
TENGIGE
UNKNOWN

ENSWOTM

1 to 120 seconds

ERRTYPE

CDLHEC
CVRD
CVS

FLC

N
Y

FRCENDHOP

N
Y

FROMDEV

BOOFLASH
DISK-0
SBY-BOOTFLASH
SBY-DISK-0

HELLOHLDWN

150 to 30000 milliseconds

HELLOINTV

100 to 10000 milliseconds

HOLDTIME

10 to 255 seconds

INACTFCTR

1 to 50

INDEX

1 to 64

LINKDIRN

BOTH
RX
TX

LPBKTYPE

FACILITY
TERMINAL

LSC

N
Y

MASTER

N
Y

MAXASSOC

0 TO 4294967295 clock ticks (2-32 second)

MODE

FRCD
NORMAL

MSGCH

AUTO
DCC
IP
OSC

MSGHOLDCOUNT

2 to 10 messages

MSGHOLDTM

100 to 10000 milliseconds

MSGMAXINTVTM

1 to 120 seconds

MSTRATUM

1 to 16

NTFCNCDE

CR
MJ
MN

OFC

N
Y

PMSTATE

ON
OFF

PSDIRN

BI
UNI

RATE

16000 to 2500000 kHz

RVRTM

0 to 720 seconds

RXFLOWID

1 to 254

SENDVER

1 to 2

THRTYPE

ALMTHR
DEGR
EVTHR
FAIL

TODEV

BOOFLASH
DISK-0
SBY-BOOTFLASH
SBY-DISK-0

TRGAPS

N
Y

TXFLOWID

1 to 254

UAP

MAINT
PROV
RTRV
SUPER

UPDATETIME

5 to 254 seconds

UPDCAL

N
Y

VALUE

1 to 9

YCABLE

N
Y

21   Where to Go Next

Related Documentation

This guide is part of a documentation set that supports the Cisco ONS 15530 and the Cisco ONS 15540 ESPx. The other documents in the set are as follows:

Obtaining Documentation

Cisco provides several ways to obtain documentation, technical assistance, and other technical resources. These sections explain how to obtain technical information from Cisco Systems.

Cisco.com

You can access the most current Cisco documentation on the World Wide Web at this URL:

http://www.cisco.com/univercd/home/home.htm

You can access the Cisco website at this URL:

http://www.cisco.com

International Cisco web sites can be accessed from this URL:

http://www.cisco.com/public/countries_languages.shtml

Documentation CD-ROM

Cisco documentation and additional literature are available in a Cisco Documentation CD-ROM package, which may have shipped with your product. The Documentation CD-ROM is updated monthly and may be more current than printed documentation. The CD-ROM package is available as a single unit or through an annual subscription.

Registered Cisco.com users can order the Documentation CD-ROM (product number DOC-CONDOCCD=) through the online Subscription Store:

http://www.cisco.com/go/subscription

Ordering Documentation

You can find instructions for ordering documentation at this URL:

http://www.cisco.com/univercd/cc/td/doc/es_inpck/pdi.htm

You can order Cisco documentation in these ways:

http://www.cisco.com/en/US/partner/ordering/index.shtml

http://www.cisco.com/go/subscription

Documentation Feedback

You can submit comments electronically on Cisco.com. On the Cisco Documentation home page, click Feedback at the top of the page.

You can email your comments to bug-doc@cisco.com.

You can submit your comments by mail by using the response card behind the front cover of your document or by writing to the following address:

Cisco Systems
Attn: Customer Document Ordering
170 West Tasman Drive
San Jose, CA 95134-9883

We appreciate your comments.

Obtaining Technical Assistance

Cisco provides Cisco.com, which includes the Cisco Technical Assistance Center (TAC) Website, as a starting point for all technical assistance. Customers and partners can obtain online documentation, troubleshooting tips, and sample configurations from the Cisco TAC website. Cisco.com registered users have complete access to the technical support resources on the Cisco TAC website, including TAC tools and utilities.

Cisco.com

Cisco.com offers a suite of interactive, networked services that let you access Cisco information, networking solutions, services, programs, and resources at any time, from anywhere in the world.

Cisco.com provides a broad range of features and services to help you with these tasks:

To obtain customized information and service, you can self-register on Cisco.com at this URL:

http://www.cisco.com

Technical Assistance Center

The Cisco TAC is available to all customers who need technical assistance with a Cisco product, technology, or solution. Two levels of support are available: the Cisco TAC website and the Cisco TAC Escalation Center. The avenue of support that you choose depends on the priority of the problem and the conditions stated in service contracts, when applicable.

We categorize Cisco TAC inquiries according to urgency:

Cisco TAC Website

You can use the Cisco TAC website to resolve P3 and P4 issues yourself, saving both cost and time. The site provides around-the-clock access to online tools, knowledge bases, and software. To access the Cisco TAC website, go to this URL:

http://www.cisco.com/tac

All customers, partners, and resellers who have a valid Cisco service contract have complete access to the technical support resources on the Cisco TAC website. Some services on the Cisco TAC website require a Cisco.com login ID and password. If you have a valid service contract but do not have a login ID or password, go to this URL to register:

http://tools.cisco.com/RPF/register/register.do

If you are a Cisco.com registered user, and you cannot resolve your technical issues by using the Cisco TAC website, you can open a case online at this URL:

http://www.cisco.com/en/US/support/index.html

If you have Internet access, we recommend that you open P3 and P4 cases through the Cisco TAC website so that you can describe the situation in your own words and attach any necessary files.

Cisco TAC Escalation Center

The Cisco TAC Escalation Center addresses priority level 1 or priority level 2 issues. These classifications are assigned when severe network degradation significantly impacts business operations. When you contact the TAC Escalation Center with a P1 or P2 problem, a Cisco TAC engineer automatically opens a case.

To obtain a directory of toll-free Cisco TAC telephone numbers for your country, go to this URL:

http://www.cisco.com/warp/public/687/Directory/DirTAC.shtml

Before calling, please check with your network operations center to determine the level of Cisco support services to which your company is entitled: for example, SMARTnet, SMARTnet Onsite, or Network Supported Accounts (NSA). When you call the center, please have available your service agreement number and your product serial number.

Obtaining Additional Publications and Information

Information about Cisco products, technologies, and network solutions is available from various online and printed sources.

http://www.cisco.com/en/US/products/products_catalog_links_launch.html

http://www.ciscopress.com

http://www.cisco.com/en/US/about/ac123/ac114/about_cisco_packet_magazine.html

http://business.cisco.com/prod/tree.taf%3fasset_id=44699&public_view=true&kbns=1.html

http://www.cisco.com/en/US/about/ac123/ac147/about_cisco_the_internet_protocol_journal.htm l

http://www.cisco.com/en/US/learning/le31/learning_recommended_training_list.html

Corporate Headquarters

Cisco Systems, Inc.

170 West Tasman Drive

San Jose, CA 95134-1706

USA

www.cisco.com

Tel: 408 526-4000

800 553-NETS (6387)

Fax: 408 526-4100

 

European Headquarters

Cisco Systems International BV

Haarlerbergpark

Haarlerbergweg 13-19

1101 CH Amsterdam

The Netherlands

www-europe.cisco.com

Tel: 31 0 20 357 1000

Fax: 31 0 20 357 1100

 

Americas Headquarters

Cisco Systems, Inc.

170 West Tasman Drive

San Jose, CA 95134-1706

USA

www.cisco.com

Tel: 408 526-7660

Fax: 408 527-0883

 

Asia Pacific Headquarters

Cisco Systems, Inc.

Capital Tower

168 Robinson Road

#22-01 to #29-01

Singapore 068912

www.cisco.com

Tel: +65 317 7777

Fax: +65 317 7799

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cisco Systems has more than 200 offices in the following countries. Addresses, phone numbers, and fax numbers are listed on the

Cisco Web site at www.cisco.com/go/offices

 

 

 

 

 

 

 

 

 

 

 

 

 

 


Printed in the USA on recycled paper containing 10% postconsumer waste.

OL-3785-01

 

 

 

 

 

 


hometocprevnextglossaryfeedbacksearchhelp
Posted: Mon Jan 19 22:22:57 PST 2004
All contents are Copyright © 1992--2004 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.