Troubleshooting

Basic Diagnostic Procedures

Verifying the Power Connection

Verifying the Ethernet Connection

Verifying the Alarm Connection

Isolating the Problem

Reading the Front Panel LEDs

Password Recovery

Technical Support

Troubleshooting


This chapter discusses basic fault investigation and diagnostic (troubleshooting) procedures for the Cisco ONS 15501.

This chapter includes the following sections:

Basic Diagnostic Procedures

Isolating the Problem

Password Recovery

Technical Support

Basic Diagnostic Procedures

When a problem occurs over the network, use the following basic diagnostic procedures to determine if the Cisco ONS 15501 is the source of the problem:

Verify the power connection.

Verify the Ethernet connection.

Verify the alarm connection.

Verifying the Power Connection

To verify the power connection, follow these steps:


Step 1 Make sure that power is securely connected to the unit and that external AC power is being applied.

Step 2 Check for LED lamp activity on the front panel. Disregard the color or number of LEDs illuminated at this time. Verify only that one or more is on, indicating that the chassis is receiving power.

Step 3 Check the following areas for possible problems if no LEDs are on:

Verify that the power connection to the chassis is firmly made.

Verify that the circuit power switch(es) are in the ON position.

Verify that the external source AC power circuit breaker(s) are on.

Verify that the external power wires are delivering power correctly.


Verifying the Ethernet Connection

To verify the Ethernet connection, follow these steps:


Step 1 Make sure that the RJ-45 connector is in good working condition and plug it into the LAN port.

Step 2 Check for LED activity on the LAN port. The left LED is green when an Ethernet connection is established. The right LED flickers yellow when a signal is being transmitted to the Ethernet.

Step 3 Check the following areas for possible problems if no LEDs are on:

Verify that the RJ-45 connection to the chassis is firmly made.

Verify that the RJ-45 connector is in good working condition.

Verify that the external Ethernet source is on and delivering a signal.


Verifying the Alarm Connection

To verify the alarm connection, connect an ohmmeter to the ALARM OUT port, through an RJ-45 connector.

If the ohmmeter shows a reading of any kind, a connection is present. A very high resistance reading indicates that there are no alarm conditions; a low resistance reading indicates that alarm conditions do exist. See "Connector Pinouts."

Isolating the Problem

The key to troubleshooting the Cisco ONS 15501 is to isolate the problem to a specific component.

When troubleshooting, consider the following components of the Cisco ONS 15501:

Power supplyIncludes the power input wiring and associated switches and fuses.

Front panel indicatorsIncludes the LEDs on the front panel, which help to identify a failure.

Connecting cablesIncludes all of the interface cables that connect the equipment to any transmission circuit or external device.

Reading the Front Panel LEDs

The front panel LEDs provide the activity or alarm status of the interfaces or internal circuitry to which they correspond. If an LED is connected to an active circuit and registers an alarm condition or is not on, a problem may exist. Table 5-1 lists the front panel LEDs and what the conditions indicate.

Table 5-1 Cisco ONS 15501 Front Panel LEDs

LED
Status
Description

Power

Green

Power is on.

Fail

Red

The temperature is out-of-range or there is a failure in the pump laser or power supply. To determine if the red LED is on because of the temperature or an actual failure, use the status command and check if the temperature is NORMAL or OUT-OF-RANGE.

LOS (loss of signal)

Yellow

No signal is detected.



Warning Infra-red laser energy may be present on the cable connected to the receiving (Input) connector, at the transmitting (Output) optical fiber connector, or the monitoring (Optical Monitor) connector. To avoid potential damage to the eyes, do not look directly into this connector or cable. When an optical cable is not attached, place the supplied protective cap over the connector and the optical fiber cable.


If the LOS (loss of signal) LED is yellow, then the input optical signal has disappeared or has fallen below the detection level.

Check to see that the input optical cable is securely seated in its connector.

Connect an optical power meter on an optical spectrum analyzer to the Output Monitor optical connector and check for proper level of the outgoing signal.

Check with the distant transmitting end to determine if the signal is leaving that site at the proper level.

Check that the input power mean and trigger values are configured correctly for the actual desired input signal.

Password Recovery

If you have forgotten your passwords, you must power cycle the system and use the restore command to reset the passwords to the defaults. The restore command can only be entered from a session on the serial RJ-232 port, not from a Telnet session.


Caution Be sure not to lose the passwords. Powercycling the system disrupts data flow.

To recover the system passwords, follow these steps


Step 1 Power cycle the system.

Step 2 Press the Enter key within 15 seconds after the password prompt appears on a HyperTerminal session on the serial console port.

Step 3 Type the restore command and press the Enter key at the "edfa >" prompt.

Step 4 Answer yes to command prompts and press the Enter key.


The default user password is edfa and the default master password is edfa1. For security reasons, you should change both passwords as soon as possible. Log in with master privileges and use the set-user-pwd and set-master-pwd commands to change the passwords.

Technical Support

If the problem exists after you review the Cisco ONS 15501 status and attempt to reprovision the amplifier, contact the Cisco Technical Assistance Center (TAC). (See the preface for contact information.)