Network Configuration Example


This section shows an example network configuration.


Note The device configurations shown in this section include some features and functions not described in this publication. For complete software configuration information, refer to the Software Configuration Guide for your switch. For complete command syntax descriptions, refer to the Command Reference for your switch.


Network Topology and Configuration

Figure 6-1 shows the example network topology.

The IP addressing and hardware configuration for the network is described in the following tables:

Table 6-1—Shows the VLAN and IP subnetwork scheme for the network

Table 6-2—Shows the Catalyst 5509 hardware configuration

Table 6-3—Shows the Catalyst 4003 hardware configuration

Table 6-4—Shows the Catalyst 5505 hardware configuration

Table 6-5—Shows the switch supervisor engine IP addresses

Table 6-6—Shows the RSM VLAN interface IP addresses

Figure 6-1 Example Network Topology

Table 6-1 VLANs and IP Subnetworks

VLAN
VLAN Name
IP Subnetwork
Hosts
Servers

1

default

10.10.1.0/24

0

0

10

Corporate

10.10.10.0/24

20

2

20

DevEng

10.10.20.0/24

90

1

30

Mfg

10.10.30.0/24

30

1

40

QA

10.10.40.0/24

45

0

50

Finance&Admin

10.10.50.0/24

30

0

60

Sales&Mktg

10.10.60.0/24

35

0


Table 6-2 Catalyst 5509 Hardware

Slot
Module

1

Supervisor Engine III (with 2-port 1000-Mbps Gigabit Ethernet uplinks)

3

Route Switch Module (RSM)

5-6

10/100-Mbps Fast Ethernet modules (12-port)

7-9

10-Mbps Ethernet modules (48-port)


Table 6-3 Catalyst 4003 Hardware

Slot
Module

1

Supervisor engine

2-3

1000-Mbps Gigabit Ethernet modules (6-port)


Table 6-4 Catalyst 5505 Hardware

Slot
Module

1

Supervisor Engine III (with 4-port 10/100-Mbps Fast Ethernet uplinks)

2

10/100-Mbps Fast Ethernet module (12-port)

3-5

10-Mbps Ethernet modules (48-port)


Table 6-5 Switch IP Addresses

Switch
In-Band (sc0) Interface IP Address

Catalyst 5509

10.10.1.10/24

Catalyst 4003

10.10.1.20/24

Catalyst 5505

10.10.1.30/24


Table 6-6 RSM IP Addresses

Interface
IP Address

VLAN 1

10.10.1.1/24

VLAN 10

10.10.10.1/24

VLAN 20

10.10.20.1/24

VLAN 30

10.10.30.1/24

VLAN 40

10.10.40.1/24

VLAN 50

10.10.50.1/24

VLAN 60

10.10.60.1/24


5509-ER-F1 (Catalyst 5509) Configuration

This section shows the configuration for 5509-ER-F1:

Enter password: <Return>
Console> enable

Enter password: <Return>
Console> (enable) set system name 5509-ER-F1
System name set.
5509-ER-F1> (enable) set system location 1st Floor Equipment Room
System location set.
5509-ER-F1> (enable) set system contact sysadmin@bigcorp.com
System contact set.
5509-ER-F1> (enable) set time 04/30/1999 9:30:00
Fri Apr 30 1999, 09:30:00
5509-ER-F1> (enable) set password
Enter old password: <Return>
Enter new password: <new_login_password>
Retype new password: <new_login_password>
Password changed.
5509-ER-F1> (enable) set enablepass
Enter old password: <Return>
Enter new password: <new_enable_password>
Retype new password: <new_enable_password>
Password changed.
5509-ER-F1> (enable) set banner motd %
5509-ER-F1 (Catalyst 5509)
Access Restricted
%
MOTD banner set
5509-ER-F1> (enable) set interface sc0 10.10.1.10/24
Interface sc0 IP address set.
5509-ER-F1> (enable) set ip route default 10.10.1.1
Route added.
5509-ER-F1> (enable) set ip dns server 10.10.10.100
10.10.10.100 added to DNS server table as primary server.
5509-ER-F1> (enable) set ip dns domain bigcorp.com
Default DNS domain name set to bigcorp.com
5509-ER-F1> (enable) set ip dns enable
DNS is enabled
5509-ER-F1> (enable) set vtp domain BigCorp mode server
VTP domain BigCorp modified
5509-ER-F1> (enable) set vlan 10 name Corporate
Vlan 10 configuration successful
5509-ER-F1> (enable) set vlan 20 name DevEng
Vlan 20 configuration successful
5509-ER-F1> (enable) set vlan 30 name Mfg
Vlan 30 configuration successful
5509-ER-F1> (enable) set vlan 40 name QA
Vlan 40 configuration successful
5509-ER-F1> (enable) set vlan 50 name Finance&Admin
Vlan 50 configuration successful
5509-ER-F1> (enable) set vlan 60 name Sales&Mktg
Vlan 60 configuration successful
5509-ER-F1> (enable) set module name 1 Supervisor III
Module name set.
5509-ER-F1> (enable) set port flowcontrol 1/1-2 send off
Ports 1/1-2 flow control send administration status set to off
(ports will not send flowcontrol to far end)
5509-ER-F1> (enable) set port flowcontrol 1/1-2 receive off
Ports 1/1-2 flow control receive administration status set to off
(ports will not allow far end to send flowcontrol)
5509-ER-F1> (enable) set port negotiation 1/1-2 enable
Ports 1/1-2 negotiation enabled
5509-ER-F1> (enable) set port name 1/1-2 GEC 802.1Q Trunk
Ports 1/1-2 name set.
5509-ER-F1> (enable) set port channel 1/1-2 desirable
Port(s) 1/1-2 channel mode set to desirable.
5509-ER-F1> (enable) set trunk 1/1 desirable dot1q
Port(s) 1/1 trunk mode set to desirable.
Port(s) 1/1 trunk type set to dot1q.
5509-ER-F1> (enable) set module name 3 RSM (RSM-ER-F1)
Module name set.
5509-ER-F1> (enable) set module name 5 Fast Ether Uplinks
Module name set.
5509-ER-F1> (enable) set port name 5/1-4 FEC ISL Trunk
Ports 5/1-4 name set.
5509-ER-F1> (enable) set port speed 5/1-4 100
Ports 5/1-4 transmission speed set to 100Mbps.
5509-ER-F1> (enable) set port duplex 5/1-4 full
Ports 5/1-4 set to full-duplex.
5509-ER-F1> (enable) set port flowcontrol 5/1-4 send off
Ports 5/1-4 flow control send administration status set to off
(ports will not send flowcontrol to far end)
5509-ER-F1> (enable) set port flowcontrol 5/1-4 receive off
Ports 5/1-4 flow control receive administration status set to off
(ports will not allow far end to send flowcontrol)
5509-ER-F1> (enable) set port negotiation 5/1-4 enable
Ports 5/1-4 negotiation enabled
5509-ER-F1> (enable) set port channel 5/1-4 desirable
Port(s) 5/1-4 channel mode set to desirable.
5509-ER-F1> (enable) set trunk 5/1 desirable isl
Port(s) 5/1 trunk mode set to desirable.
Port(s) 5/1 trunk type set to isl.
5509-ER-F1> (enable) set module name 6 DevEng 100Mb Hosts
Module name set.
5509-ER-F1> (enable) set port name 6/1 DE Sparc Ultra
Port 6/1 name set.
5509-ER-F1> (enable) set port name 6/2-7 DE Sparc20
Ports 6/2-7 name set.
5509-ER-F1> (enable) set port name 6/8-12 DE NT Workstation
Ports 6/8-12 name set.
5509-ER-F1> (enable) set port speed 6/1-12 100
Ports 6/1-12 transmission speed set to 100Mbps.
5509-ER-F1> (enable) set port duplex 6/1-12 full
Ports 6/1-12 set to full-duplex.
5509-ER-F1> (enable) set port flowcontrol 6/1-12 send desired
Ports 6/1-12 flow control send administration status set to desired
(ports will send flowcontrol to far end if far end supports it)
5509-ER-F1> (enable) set port flowcontrol 6/1-12 receive desired
Ports 6/1-12 flow control receive administration status set to desired
(ports will allow far end to send flowcontrol if far end supports it)
5509-ER-F1> (enable) set port channel 6/1-12 off
Port(s) 6/1-12 channel mode set to off.
5509-ER-F1> (enable) set trunk 6/1-12 off
Port(s) 6/1-12 trunk mode set to off.
5509-ER-F1> (enable) set spantree portfast 6/1-12 enable

Warning: Spantree port fast start should only be enabled on ports connected
to a single host. Connecting hubs, concentrators, switches, bridges, etc. to
a fast start port can cause temporary spanning tree loops. Use with caution.

Spantree ports 6/1-12 fast start enabled.
5509-ER-F1> (enable) set vlan 20 6/1-12
VLAN 20 modified.
VLAN 1 modified.
VLAN Mod/Ports
---- -----------------------
20 1/1-2
5/1-4
6/1-12
5509-ER-F1> (enable) set module name 7 Corp/Mfg 10Mb Hosts
Module name set.
5509-ER-F1> (enable) set port name 7/1-12 Corp Win98 PC
Ports 7/1-12 name set.
5509-ER-F1> (enable) set port name 7/13-48 Mfg Win98 PC
Ports 7/13-48 name set.
5509-ER-F1> (enable) set port duplex 7/1-48 full
Ports 7/1-48 set to full-duplex.
5509-ER-F1> (enable) set spantree portfast 7/1-48 enable

Warning: Spantree port fast start should only be enabled on ports connected
to a single host. Connecting hubs, concentrators, switches, bridges, etc. to
a fast start port can cause temporary spanning tree loops. Use with caution.

Spantree ports 7/1-48 fast start enabled.
5509-ER-F1> (enable) set vlan 10 7/1-12
VLAN 10 modified.
VLAN 1 modified.
VLAN Mod/Ports
---- -----------------------
10 1/1-2
5/1-4
7/1-12
5509-ER-F1> (enable) set vlan 30 7/13-48
VLAN 30 modified.
VLAN 1 modified.
VLAN Mod/Ports
---- -----------------------
30 1/1-2
5/1-4
7/13-48
5509-ER-F1> (enable) set module name 8 DevEng 10Mb Hosts
Module name set.
5509-ER-F1> (enable) set port name 8/1-48 DevEng WinNT PC
Ports 8/1-48 name set.
5509-ER-F1> (enable) set port duplex 8/1-48 full
Ports 8/1-48 set to full-duplex.
5509-ER-F1> (enable) set spantree portfast 8/1-48 enable

Warning: Spantree port fast start should only be enabled on ports connected
to a single host. Connecting hubs, concentrators, switches, bridges, etc. to
a fast start port can cause temporary spanning tree loops. Use with caution.

Spantree ports 8/1-48 fast start enabled.
5509-ER-F1> (enable) set vlan 20 8/1-48
VLAN 20 modified.
VLAN 1 modified.
VLAN Mod/Ports
---- -----------------------
20 1/1-2
5/1-4
6/1-12
8/1-48
5509-ER-F1> (enable) set module name 9 DevEng 10Mb Hosts
Module name set.
5509-ER-F1> (enable) set port name 9/1-48 DevEng WinNT PC
Ports 9/1-48 name set.
5509-ER-F1> (enable) set port duplex 9/1-48 full
Ports 9/1-48 set to full-duplex.
5509-ER-F1> (enable) set spantree portfast 9/1-48 enable

Warning: Spantree port fast start should only be enabled on ports connected
to a single host. Connecting hubs, concentrators, switches, bridges, etc. to
a fast start port can cause temporary spanning tree loops. Use with caution.

Spantree ports 9/1-48 fast start enabled.
5509-ER-F1> (enable) set vlan 20 9/1-48
VLAN 20 modified.
VLAN 1 modified.
VLAN Mod/Ports
---- -----------------------
20 1/1-2
5/1-4
6/1-12
8/1-48
9/1-48
5509-ER-F1> (enable)

4003-ER-F1 (Catalyst 4003) Configuration

This section shows the configuration for 4003-ER-F1:

Enter password: <Return>
Console> enable

Enter password: <Return>
Console> (enable) set system name 4003-ER-F1
System name set.
4003-ER-F1> (enable) set system location 1st Floor Equipment Room
System location set.
4003-ER-F1> (enable) set system contact sysadmin@bigcorp.com
System contact set.
4003-ER-F1> (enable) set time 04/30/1999 9:45:00
Fri Apr 30 1999, 09:45:00
4003-ER-F1> (enable) set password
Enter old password: <Return>
Enter new password: <new_login_password>
Retype new password: <new_login_password>
Password changed.
4003-ER-F1> (enable) set enablepass
Enter old password: <Return>
Enter new password: <new_enable_password>
Retype new password: <new_enable_password>
Password changed.
4003-ER-F1> (enable) set banner motd %
4003-ER-F1 (Catalyst 4003)
Access Restricted
%
MOTD banner set
4003-ER-F1> (enable) set interface sc0 10.10.1.20/24
Interface sc0 IP address set.
4003-ER-F1> (enable) set ip route default 10.10.1.1
Route added.
4003-ER-F1> (enable) set ip dns server 10.10.10.100
10.10.10.100 added to DNS server table as primary server.
4003-ER-F1> (enable) set ip dns domain bigcorp.com
Default DNS domain name set to bigcorp.com
4003-ER-F1> (enable) set ip dns enable
DNS is enabled
4003-ER-F1> (enable) set vtp domain BigCorp mode client
VTP domain BigCorp modified
4003-ER-F1> (enable) set module name 1 Supervisor
Module name set.
4003-ER-F1> (enable) set module name 2 Gig Uplinks
Module name set.
4003-ER-F1> (enable) set port flowcontrol 2/1-2 send off
Ports 2/1-2 flow control send administration status set to off
(ports will not send flowcontrol to far end)
4003-ER-F1> (enable) set port flowcontrol 2/1-2 receive off
Ports 2/1-2 flow control receive administration status set to off
(ports will not allow far end to send flowcontrol)
4003-ER-F1> (enable) set port negotiation 2/1-2 enable
Ports 2/1-2 negotiation enabled
4003-ER-F1> (enable) set port name 2/1-2 GEC 802.1Q Trunk
Ports 2/1-2 name set.
4003-ER-F1> (enable) set port channel 2/1-2 desirable
Port(s) 2/1-2 channel mode set to desirable.
4003-ER-F1> (enable) set trunk 2/1 desirable dot1q
Port(s) 2/1-2 trunk mode set to desirable.
Port(s) 2/1-2 trunk type set to dot1q.
4003-ER-F1> (enable) set module name 3 Gig Server Links
Module name set.
4003-ER-F1> (enable) set port name 3/1-2 Corporate Server
Ports 3/1-2 name set.
4003-ER-F1> (enable) set port name 3/3 DevEng Server
Port 3/3 name set.
4003-ER-F1> (enable) set port name 3/4 QA Server
Port 3/4 name set.
4003-ER-F1> (enable) set port flowcontrol 3/1-4 send desired
Ports 3/1-4 flow control send administration status set to desired
(ports will send flowcontrol to far end if far end supports it)
4003-ER-F1> (enable) set port flowcontrol 3/1-4 receive desired
Ports 3/1-4 flow control receive administration status set to desired
(ports will allow far end to send flowcontrol if far end supports it)
4003-ER-F1> (enable) set port channel 3/1-2 off
Port(s) 3/1-2 channel mode set to off.
4003-ER-F1> (enable) set port channel 3/3-4 off
Port(s) 3/3-4 channel mode set to off.
4003-ER-F1> (enable) set trunk 3/1-4 off
Port(s) 3/1-4 trunk mode set to off.
4003-ER-F1> (enable) set spantree portfast 3/1-4 enable

Warning: Spantree port fast start should only be enabled on ports connected
to a single host. Connecting hubs, concentrators, switches, bridges, etc. to
a fast start port can cause temporary spanning tree loops. Use with caution.

Spantree ports 3/1-4 fast start enabled.
4003-ER-F1> (enable) set vlan 10 3/1-2
VLAN 10 modified.
VLAN 1 modified.
VLAN Mod/Ports
---- -----------------------
10 2/1-2
3/1-2
4003-ER-F1> (enable) set vlan 20 3/3
VLAN 20 modified.
VLAN 1 modified.
VLAN Mod/Ports
---- -----------------------
20 2/1-2
3/3
4003-ER-F1> (enable) set vlan 40 3/4
VLAN 40 modified.
VLAN 1 modified.
VLAN Mod/Ports
---- -----------------------
40 2/1-2
3/4
4003-ER-F1> (enable)

RSM-ER-F1 (RSM) Configuration


Note For complete configuration procedures for the Route Switch Module (RSM), refer to the Software Configuration Guide for the Catalyst 5000 family switches.


This section shows the configuration for RSM-ER-F1:

5509-ER-F1> (enable) session 3
Trying Router-3...
Connected to Router-3.
Escape character is '^]'.

Router>enable
Router#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Router(config)#hostname RSM-ER-F1
RSM-ER-F1(config)#enable password extra_secret_word
RSM-ER-F1(config)#line vty 0 6
RSM-ER-F1(config-line)#password secret_word
RSM-ER-F1(config-line)#ip domain-name bigcorp.com
RSM-ER-F1(config)#ip name-server 10.10.10.100
RSM-ER-F1(config)#ip domain-lookup
RSM-ER-F1(config)#interface vlan 1
RSM-ER-F1(config-if)#description default (vlan1) VLAN interface
RSM-ER-F1(config-if)#ip address 10.10.1.1 255.255.255.0
RSM-ER-F1(config-if)#no shutdown
RSM-ER-F1(config-if)#interface vlan 10
RSM-ER-F1(config-if)#description Corporate (vlan10) VLAN interface
RSM-ER-F1(config-if)#ip address 10.10.10.1 255.255.255.0
RSM-ER-F1(config-if)#no shutdown
RSM-ER-F1(config-if)#interface vlan 20
RSM-ER-F1(config-if)#description DevEng (vlan20) VLAN interface
RSM-ER-F1(config-if)#ip address 10.10.20.1 255.255.255.0
RSM-ER-F1(config-if)#no shutdown
RSM-ER-F1(config-if)#interface vlan 30
RSM-ER-F1(config-if)#description Mfg (vlan30) VLAN interface
RSM-ER-F1(config-if)#ip address 10.10.30.1 255.255.255.0
RSM-ER-F1(config-if)#no shutdown
RSM-ER-F1(config-if)#interface vlan 40
RSM-ER-F1(config-if)#description QA (vlan40) VLAN interface
RSM-ER-F1(config-if)#ip address 10.10.40.1 255.255.255.0
RSM-ER-F1(config-if)#no shutdown
RSM-ER-F1(config-if)#interface vlan 50
RSM-ER-F1(config-if)#description Finance&Admin (vlan50) VLAN interface
RSM-ER-F1(config-if)#ip address 10.10.50.1 255.255.255.0
RSM-ER-F1(config-if)#no shutdown
RSM-ER-F1(config-if)#interface vlan 60
RSM-ER-F1(config-if)#description Sales&Mktg (vlan60) VLAN interface
RSM-ER-F1(config-if)#ip address 10.10.60.1 255.255.255.0
RSM-ER-F1(config-if)#no shutdown
RSM-ER-F1(config-if)#^Z
RSM-ER-F1#copy running-config startup-config
Building configuration...
[OK]
RSM-ER-F1#

5505-WC-F2 (Catalyst 5505) Configuration

This section shows the configuration for 5505-WC-F2:

Enter password: <Return>
Console> enable

Enter password: <Return>
Console> (enable) set system name 5505-WC-F2
System name set.
5505-WC-F2> (enable) set system location 2nd Floor Wiring Closet
System location set.
5505-WC-F2> (enable) set system contact sysadmin@bigcorp.com
System contact set.
5505-WC-F2> (enable) set time 04/30/1999 10:00:00
Fri Apr 30 1999, 10:00:00
5505-WC-F2> (enable) set password
Enter old password: <Return>
Enter new password: <new_login_password>
Retype new password: <new_login_password>
Password changed.
5505-WC-F2> (enable) set enablepass
Enter old password: <Return>
Enter new password: <new_enable_password>
Retype new password: <new_enable_password>
Password changed.
5505-WC-F2> (enable) set banner motd %
5505-WC-F2 (Catalyst 5505)
Access Restricted
%
MOTD banner set
5505-WC-F2> (enable) set interface sc0 10.10.1.30/24
Interface sc0 IP address set.
5505-WC-F2> (enable) set ip route default 10.10.1.1
Route added.
5505-WC-F2> (enable) set ip dns server 10.10.10.100
10.10.10.100 added to DNS server table as primary server.
5505-WC-F2> (enable) set ip dns domain bigcorp.com
Default DNS domain name set to bigcorp.com
5505-WC-F2> (enable) set ip dns enable
DNS is enabled
5505-WC-F2> (enable) set vtp domain BigCorp mode client
VTP domain BigCorp modified
5505-WC-F2> (enable) set module name 1 Supervisor III
Module name set.
5505-WC-F2> (enable) set port name 1/1-4 FEC ISL Trunk
Ports 1/1-4 name set.
5505-WC-F2> (enable) set port speed 1/1-4 100
Ports 1/1-4 transmission speed set to 100Mbps.
5505-WC-F2> (enable) set port duplex 1/1-4 full
Ports 1/1-4 set to full-duplex.
5505-WC-F2> (enable) set port flowcontrol 1/1-4 send off
Ports 1/1-4 flow control send administration status set to off
(ports will not send flowcontrol to far end)
5505-WC-F2> (enable) set port flowcontrol 1/1-4 receive off
Ports 1/1-4 flow control receive administration status set to off
(ports will not allow far end to send flowcontrol)
5505-WC-F2> (enable) set port negotiation 1/1-4 enable
Ports 1/1-4 negotiation enabled
5505-WC-F2> (enable) set port channel 1/1-4 desirable
Port(s) 1/1-4 channel mode set to desirable.
5505-WC-F2> (enable) set trunk 1/1 desirable isl
Port(s) 1/1 trunk mode set to desirable.
Port(s) 1/1 trunk type set to isl.
5505-WC-F2> (enable) set module name 2 QA 100Mb Hosts
Module name set.
5505-WC-F2> (enable) set port name 2/1-4 QA Sparc20
Port 2/1-4 name set.
5505-WC-F2> (enable) set port name 2/5-12 QA NT Workstation
Ports 2/5-12 name set.
5505-WC-F2> (enable) set port speed 2/1-12 100
Ports 2/1-12 transmission speed set to 100Mbps.
5505-WC-F2> (enable) set port duplex 2/1-12 full
Ports 2/1-12 set to full-duplex.
5505-WC-F2> (enable) set port flowcontrol 2/1-12 send desired
Ports 2/1-12 flow control send administration status set to desired
(ports will send flowcontrol to far end if far end supports it)
5505-WC-F2> (enable) set port flowcontrol 2/1-12 receive desired
Ports 2/1-12 flow control receive administration status set to desired
(ports will allow far end to send flowcontrol if far end supports it)
5505-WC-F2> (enable) set port channel 2/1-12 off
Port(s) 2/1-12 channel mode set to off.
5505-WC-F2> (enable) set trunk 2/1-12 off
Port(s) 2/1-12 trunk mode set to off.
5505-WC-F2> (enable) set spantree portfast 2/1-12 enable

Warning: Spantree port fast start should only be enabled on ports connected
to a single host. Connecting hubs, concentrators, switches, bridges, etc. to
a fast start port can cause temporary spanning tree loops. Use with caution.

Spantree ports 2/1-12 fast start enabled.
5505-WC-F2> (enable) set vlan 40 2/1-12
VLAN 40 modified.
VLAN 1 modified.
VLAN Mod/Ports
---- -----------------------
40 1/1-4
2/1-12
5505-WC-F2> (enable) set module name 3 QA 10Mb Hosts
Module name set.
5505-WC-F2> (enable) set port name 3/1-48 QA WinNT PC
Ports 3/1-48 name set.
5505-WC-F2> (enable) set port duplex 3/1-48 full
Ports 3/1-48 set to full-duplex.
5505-WC-F2> (enable) set spantree portfast 3/1-48 enable

Warning: Spantree port fast start should only be enabled on ports connected
to a single host. Connecting hubs, concentrators, switches, bridges, etc. to
a fast start port can cause temporary spanning tree loops. Use with caution.

Spantree ports 3/1-48 fast start enabled.
5505-WC-F2> (enable) set vlan 40 3/1-48
VLAN 40 modified.
VLAN 1 modified.
VLAN Mod/Ports
---- -----------------------
40 1/1-4
2/1-12
3/1-48
5505-WC-F2> (enable) set module name 4 Corp/F&A 10Mb Hosts
Module name set.
5505-WC-F2> (enable) set port name 4/1-12 Corp Win98 PC
Ports 4/1-12 name set.
5505-WC-F2> (enable) set port name 4/13-48 F&A Win98 PC
Ports 4/13-48 name set.
5505-WC-F2> (enable) set port duplex 4/1-48 full
Ports 4/1-48 set to full-duplex.
5505-WC-F2> (enable) set spantree portfast 4/1-48 enable

Warning: Spantree port fast start should only be enabled on ports connected
to a single host. Connecting hubs, concentrators, switches, bridges, etc. to
a fast start port can cause temporary spanning tree loops. Use with caution.

Spantree ports 4/1-48 fast start enabled.
5505-WC-F2> (enable) set vlan 10 4/1-12
VLAN 10 modified.
VLAN 1 modified.
VLAN Mod/Ports
---- -----------------------
10 1/1-4
4/1-12
5505-WC-F2> (enable) set vlan 50 4/13-48
VLAN 50 modified.
VLAN 1 modified.
VLAN Mod/Ports
---- -----------------------
50 1/1-4
4/13-48
5505-WC-F2> (enable) set module name 5 S&M 10Mb Hosts
Module name set.
5505-WC-F2> (enable) set port name 5/1-48 S&M Win98 PC
Ports 5/1-48 name set.
5505-WC-F2> (enable) set port duplex 5/1-48 full
Ports 5/1-48 set to full-duplex.
5505-WC-F2> (enable) set spantree portfast 5/1-48 enable

Warning: Spantree port fast start should only be enabled on ports connected
to a single host. Connecting hubs, concentrators, switches, bridges, etc. to
a fast start port can cause temporary spanning tree loops. Use with caution.

Spantree ports 5/1-48 fast start enabled.
5505-WC-F2> (enable) set vlan 60 5/1-48
VLAN 60 modified.
VLAN 1 modified.
VLAN Mod/Ports
---- -----------------------
60 1/1-4
5/1-48

5505-WC-F2> (enable)