cc/td/doc/product/lan/cat5000/hardware
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Specifications
Catalyst 5002 Switch
Catalyst 5000 and Catalyst 5505 Switches
Catalyst 5509 Switch
Catalyst 5500 Switch

Specifications


This appendix provides technical specifications for these Catalyst 5000 family switches:

Refer to the Catalyst 5000 Family Module Installation Guide for switching module and interface port specifications.

Catalyst 5002 Switch

Catalyst 5002 switch specifications are provided in Table A-1.

Table A-1   Catalyst 5002 Switch Specifications

Item Specification
Environmental

 

 

Temperature, ambient operating

32°F (0°C) to 104°F (40°C)

Temperature, ambient nonoperating and storage

-40 to 158°F (-40 to 70°C)

Humidity (RH), ambient (noncondensing) operating

10% to 90%

Humidity (RH), ambient (noncondensing) nonoperating and storage

5% to 95%

Altitude, operating and nonoperating

Sea level to 10,000 ft. (3050 m)

Switching Components

Backplane

1.2 Gbps

Microprocessor

Supervisor Engines I and II: 25-MHz 68EC040 for the NMP1

Supervisor Engines II G and III G: 37.5-MHz MCF5102 for the NMP

Memory

Supervisor Engine I

Supervisor Engine II

Supervisor Engine II G

Supervisor Engine III G

DRAM2: 20 MB; Flash (onboard)-4 MB;
NVRAM-256 KB

DRAM: 16 MB; Flash (onboard)-8 MB;
NVRAM-256 KB

DRAM: 32 MB; Flash (onboard)-8 MB;
NVRAM-256 KB

DRAM: 32 MB; Flash (onboard)-8 MB;
NVRAM-256 KB

Physical Characteristics

Dimensions (H x W x D)

5.75 x 17 x 18 in. (14.6 x 43.18 x 46.72 cm)

Weight

35 lb (15.9 kg) with 2 power supplies, 1 switching module, and 1 supervisor engine

Shock and Vibration

 

Shock

54 inches per second (1.37 meters per second)

Vibration

0.35 g from 3 to 500 Hz

 

AC Power without Power Factor Correction

 

 

Power supply output capacity

155W maximum

System power dissipation

155W maximum configuration, 120W typical

System heat dissipation

850 Btus3/hr

AC-input voltage

100 to 240 VAC

AC frequency

50 to 60 Hz

AC-input current

5.0A maximum

Power supply output

+5.15V @ 26A, +12V @ 1.5A, +24V @ 0.1A

AC Power with Power Factor Correction

 

 

Power supply output capacity

175W maximum

System power dissipation

175W maximum configuration, 100W typical

System heat dissipation

950 Btus/hr

AC-input voltage

90 to 264 VAC autoranging

AC frequency

47 to 63 Hz

AC-input current

3.0A maximum @ 110 VAC, 1.5A maximum @
220 VAC

Power supply output

+5.15V @ 30A, +12V @ 1.5A, +24V @ 0.1A

DC Power

 

 

Power supply output capacity

175W maximum

System power dissipation

175W maximum, 120W typical

DC-input voltage
Typical range (U.S. and Canada)
Typical range (International)

-48 VDC to -60 VDC continuous
-48 VDC (nominal) -56 VDC (high) -40.5 VDC (low)
-60 VDC (nominal) -72 VDC (high) -55 VDC (low)

DC-input current

6A

Power supply output

+5.15V @ 30A, +12V @ 1.5A, +24V @ 0.1A

DC power-cable wire gauge

14 AWG 90\xb0 C copper conductors

Airflow

200 lfm4 through system fan assembly

Agency Approvals
  Safety


  EMI5


UL6 1950, CSA7-C22.2 No. 950, EN860950, and IEC9 950, TS10 001, AS/NZS11 3260, CE12 Marking,
EN 60825, IEC 60825, 21CFR1040

FCC13 Part 15, Class A (CFR14 47) (USA), ICES15-003 Class A (Canada), EN55022 Class A (Europe), CISPR22 Class A (International), AS/NZS 3548 Class A (Australia), and VCCI Class A (Japan) with UTP16


EN55022 Class B (Europe), CISPR22 Class B (International), AS/NZS 3548 Class B, and VCCI17 Class B (Japan) with FTP18 cables

1NMP = network management processor

2DRAM = dynamic random-access memory

3Btus = British thermal units

4lfm = linear feet per minute

5EMI = electromagnetic interference

6UL = Underwriters Laboratory

7CSA = Canadian Standards Association

8EN = European Norm

9IEC = International Electrotechnical Commission

10TS = Technical Specification

11AS/NZS = Standards Australia/Standards New Zealand

12CE = European Compliance

13FCC = Federal Communications Commission

14CFR = Code of Federal Regulations

15ICES = International Commerce Exchange Systems

16UTP = unshielded twisted-pair

17VCCI = Voluntary Control Council for Information Technology Equipment

18FTP = foil twisted-pair

Catalyst 5000 and Catalyst 5505 Switches

The specifications for the Catalyst 5000 and Catalyst 5505 switches are provided in Table A-2.

Table A-2   Catalyst 5000 Switch and Catalyst 5505 Switch Specifications

Item Specification
Environmental

Temperature, ambient operating

32°F (0°C) to 104°F (40°C)

Temperature, ambient nonoperating and storage

-40 to 150\xb0 F (-40 to 70\xb0 C)

Humidity (RH), ambient (noncondensing) operating

10% to 90%

Humidity (RH), ambient (noncondensing) nonoperating and storage

5% to 95%

Altitude, operating and nonoperating

Sea level to 10,000 ft. (3050 m)

Switching Components

Backplane

Catalyst 5000 switch-1.2 Gbps

Catalyst 5505 switch-3.6 Gbps

Switching Components (continued)

Microprocessor

Supervisor Engines I and II: 25-MHz 68EC040 for the NMP1

Supervisor Engine III, Supervisor Engine III F: 150-MHz IDT R4700 RISC

Supervisor Engines II G and III G: 37.5-MHz MCF5102 for the NMP

Memory

 

Supervisor Engine I (Catalyst 5000 switch only)

Supervisor Engine II

Supervisor Engine II G

Supervisor Engine III

Supervisor Engine III F

Supervisor Engine III G

DRAM2: 20 MB; Flash (onboard)-4 MB;
NVRAM3-256 KB

DRAM: 16 MB; Flash (onboard)-8 MB;
NVRAM-256 KB

DRAM: 32 MB; Flash (onboard)-8 MB;
NVRAM-256 KB

DRAM: 64 MB; Flash (onboard)-8 MB; Flash PC Card-16 MB or 20 MB; NVRAM-512 KB

DRAM: 32 MB; Flash (onboard)-8 MB;
NVRAM-512 KB

DRAM: 32 MB; Flash (onboard)-8 MB;
NVRAM-256 KB

Physical Characteristics

Dimensions (H x W x D)

10.4 x 17.25 x 18.4 in. (26.4 x 43.1 x 46.0 cm)
Chassis depth including cable guide is 21.64 in.
(55.0 cm)

Weight

Chassis only: 43 lb (19.5 kg)
Chassis fully configured with 1 supervisor engine, 4 switching modules, and 2 power supplies: 84 lb
(39 kg)

Shock and Vibration

 

 

Shock

42 inches per second (1.07 meters per second)

Vibration

0.35 g from 3 to 500 Hz

 

Power

Power supply output capacity

376W maximum (AC-input or DC-input power supplies)

System power dissipation (AC and DC supplies)

350W maximum configuration, 250W typical with maximum configuration

System heat dissipation (AC supply)

563W (1919 Btus4/hr)

System heat dissipation (DC supply)

600W (2040 Btus/hr)

 

AC-input voltage

100 to 127/200 to 240 VAC wide input with power factor corrector

DC-input voltage
Typical range (U.S. and Canada)
Typical range (International)

-48 VDC to -60 VDC continuous
-48 VDC (nominal) -54 VDC (high) -42 VDC (low)
-60 VDC (nominal) -72 VDC (high) -52 VDC (low)

AC frequency

50 to 60 Hz

DC power-cable wire gauge

10 to 12 AWG 90\xb0 C copper conductors

AC-input current

8/4A with full configuration (maximum of 0.8 kVA)

DC-input current

12.0A maximum @ 48V (nominal)
10.0A maximum @ 60V (nominal)

Power supply output

+5.15V @ 70A, +12V @ 2A, +24V @ 0.12A

Airflow

200 lfm5 through system fan assembly

Agency Approvals
  Safety


  EMI6


UL7 1950, CSA8-C22.2 No. 950, EN960950, and IEC10 950, TS11 001, AS/NZS12 3260 CE13 Marking,
EN 60825, IEC 60825, 21CFR1040

FCC14 Part 15, Class A (CFR15 47) (USA), ICES16-003 Class A (Canada), EN55022 Class A (Europe), CISPR22 Class A (International), AS/NZS 3548 Class A (Australia), and VCCI Class A (Japan) with UTP17


EN55022 Class B (Europe), CISPR22 Class B (International), AS/NZS 3548 Class B, and VCCI18 Class B (Japan) with FTP19 cables

1NMP = network management processor

2DRAM = dynamic random-access memory

3NVRAM = nonvolatile RAM

4Btus = British thermal units

5lfm = linear feet per minute

6EMI = electromagnetic interference

7UL = Underwriters Laboratory

8CSA = Canadian Standards Association

9EN = European Norm

10IEC = International Electrotechnical Commission

11TS = Technical Specification

12AS/NZS = Standards Australia/Standards New Zealand

13CE = European Compliance

14FCC = Federal Communications Commission

15CFR = Code of Federal Regulations

16ICES = International Commerce Exchange Systems

17UTP = unshielded twisted-pair

18VCCI = Voluntary Control Council for Information Technology Equipment

19FTP = foil twisted-pair

Catalyst 5509 Switch

Catalyst 5509 switch specifications are provided in Table A-3.

Table A-3   Catalyst 5509 Switch Specifications

Item Specification
Environmental

Temperature, ambient operating

32°F (0°C) to 104°F (40°C)

Temperature, ambient nonoperating and storage

-40 to 158°F (-40 to 70°C)

Humidity (RH), ambient (noncondensing) operating

10% to 90%

Humidity (RH), ambient (noncondensing) nonoperating and storage

5% to 95%

Altitude, operating and nonoperating

Sea level to 10,000 ft. (3050 m)

Switching Components

Backplane

3.6 Gbps

Microprocessor

Supervisor Engine II: 25-MHz 68EC040 for the NMP1

Supervisor Engine III, Supervisor Engine III F: 150-MHz IDT R4700 RISC

Supervisor Engines II G and III G: 37.5-MHz MCF5102 for the NMP

Memory

Supervisor Engine II

Supervisor Engine II G

Supervisor Engine III

Supervisor Engine III F

Supervisor Engine III G

DRAM2: 16 MB; Flash (onboard)-8 MB;
NVRAM3-256 KB

DRAM: 32 MB; Flash (onboard)-8 MB;
NVRAM-256 KB

DRAM: 64 MB; Flash (onboard)-8 MB; Flash PC Card-16 MB or 20 MB; NVRAM-512 KB

DRAM: 32 MB; Flash (onboard)-8 MB;
NVRAM-512 KB

DRAM: 32 MB; Flash (onboard)-8 MB;
NVRAM-256 KB

Physical Characteristics

Dimensions (H x W x D)

20 x 17.25 x 18.4 in. (50.8 x 43.1 x 46.0 cm)
Chassis depth including cable guide is 21.64 in.
(55.0 cm)

Weight

Chassis only: 55 lb (24.9 kg)

Chassis fully configured with 1 supervisor engine, 4 switching modules, and 2 power supplies: 135 lb (61.2 kg)

Shock and Vibration

Shock

42 inches per second (1.07 meters per second)

Vibration

0.35 g from 3 to 500 Hz

 

Power

Power supply output capacity

805W maximum (AC-input or DC-input power supplies)

System power dissipation (AC and DC supplies)

805W maximum configuration, 600W typical with maximum configuration

System heat dissipation (AC supply)

1150W (3920 Btus4/hr) maximum

System heat dissipation (DC supply)

1150W (3920 Btus/hr) maximum

AC-input voltage

100 to 240 VAC wide input with power factor corrector

DC-input voltage
Typical range (U.S. and Canada)
Typical range (International)

-48 VDC to -60 VDC continuous
-48 VDC (nominal) -54 VDC (high) -42 VDC (low)
-60 VDC (nominal) -72 VDC (high) -52 VDC (low)

AC frequency

50 to 60 Hz

DC power-cable wire gauge

10 AWG 90\xb0 C copper conductors

AC-input current

12-6A (805W power supply) or 16-7A (1100W power supply)

DC-input current

25.0A (1100W power supply) or 40.0A (1200W power supply)

Power supply output

+5.15V @ 140A, +12V @ 4A, +24V @ 1.5A

Airflow

200 lfm5 through system fan assembly

Agency Approvals
  Safety


  EMI6


UL7 1950, CSA8-C22.2 No. 950, EN960950, and IEC10 950, TS11 001, AS/NZS12 3260 CE13 Marking,
EN 60825, IEC 60825, 21CFR1040

FCC14 Part 15, Class A (CFR15 47) (USA), ICES16-003 Class A (Canada), EN55022 Class A (Europe), CISPR22 Class A (International), AS/NZS 3548 Class A (Australia), and VCCI Class A (Japan) with UTP17


EN55022 Class B (Europe), CISPR22 Class B (International), AS/NZS 3548 Class B, and VCCI18 Class B (Japan) with FTP19 cables

1NMP = network management processor

2DRAM = dynamic random-access memory

3NVRAM = nonvolatile random-access memory

4Btus = British thermal units

5lfm = linear feet per minute

6EMI = electromagnetic interference

7UL = Underwriters Laboratory

8CSA = Canadian Standards Association

9EN = European Norm

10IEC = International Electrotechnical Commission

11TS = Technical Specification

12AS/NZS = Standards Australia/Standards New Zealand

13CE = European Compliance

14FCC = Federal Communications Commission

15CFR = Code of Federal Regulations

16ICES = International Commerce Exchange Systems

17UTP = unshielded twisted-pair

18VCCI = Voluntary Control Council for Information Technology Equipment

19FTP = foil twisted-pair

Catalyst 5500 Switch

Catalyst 5500 switch specifications are provided in Table A-4.

Table A-4   Catalyst 5500 Switch Specifications

Item Specification
Environmental

 

 

Temperature, ambient operating

32°F (0°C) to 104°F (40°C)

Temperature, ambient nonoperating and storage

-40°F (-40°C) to 158°F (70°C)

Humidity (RH), ambient (noncondensing) operating

10% to 90%

Humidity (RH), ambient (noncondensing) nonoperating and storage

5% to 95%

Altitude, operating and nonoperating

Sea level to 10,000 ft (3050 m)

Vibration, operating

5 to 200 Hz, 0.5 g (1 oct/min)

Vibration, nonoperating

5 to 200 Hz, 1 g (1 oct/min)
200 to 500 Hz, 2 g (1 oct/min)

Switching Components

Backplane

3.6 Gbps
5-Gbps cell-based switching fabric for ATM

Switching Components (continued)

Microprocessor

Supervisor Engine II: 25-MHz 68EC040 for the NMP1

Supervisor Engine III, Supervisor Engine III F: 150-MHz IDT R4700 RISC

Supervisor Engines II G and III G: 37.5-MHz MCF5102 for the NMP

Memory

 

Supervisor Engine II

Supervisor Engine II G

Supervisor Engine III

Supervisor Engine III F

Supervisor Engine III G

DRAM2: 16 MB; Flash (onboard)-8 MB;
NVRAM3-256 KB

DRAM: 32 MB; Flash (onboard)-8 MB;
NVRAM-256 KB

DRAM: 64 MB; Flash (onboard)-8 MB; Flash PC Card-16 MB or 20 MB; NVRAM-512 KB

DRAM: 32 MB; Flash (onboard)-8 MB;
NVRAM-512 KB

DRAM: 32 MB; Flash (onboard)-8 MB;
NVRAM-256 KB

Physical Characteristics

Dimensions (H x W x D)

25 x 17.25 x 18.4 in. (62.5 x 43.1 x 46.0 cm)
Depth including cable guide: 21.64 in. (55.0 cm)

Weight

Chassis only: 61 lb (22.75 kg)
Full configuration: 13 switching modules and 2 power supplies, 176 lb (65.65 kg)

Shock and Vibration

 

 

Shock

21 inches per second (0.53 meters per second)

Vibration

0.35 g from 3 to 500 Hz

Power

Power supply output capacity

1100W maximum (AC-input or DC-input power supplies)

System power dissipation

1100W maximum configuration, 750W typical with maximum configuration

System heat dissipation

1571W (5360 Btus4/hr)

AC-input voltage

100 to 240 VAC wide input with power factor corrector

DC-input voltage
Typical range (U.S. and Canada)
Typical range (International)

-48 VDC to -60 VDC continuous
-48 VDC (nominal) -54 VDC (high) -42 VDC (low)
-60 VDC (nominal) -72 VDC (high) -52 VDC (low)

AC frequency

50 to 60 Hz

DC power-cable wire gauge

8 AWG 90\xb0 C copper conductors

AC-input current

16-7A with full configuration (maximum of 1.8 kVA)

DC-input current

35A or 40A

Power supply output

200A @ +5.15V, 6 A @ +12V, 2A @ +24V

Airflow

200 lfm5 through system fan assembly

Agency Approvals
  Safety


  EMI6

UL7 1950, CSA8-C22.2 No. 950, EN960950, and IEC10 950, TS11 001, AS/NZS12 3260 CE13 Marking,
EN 60825, IEC 60825, 21CFR1040

FCC14 Part 15, Class A (CFR15 47) (USA), ICES16-003 Class A (Canada), EN55022 Class A (Europe), CISPR22 Class A (International), AS/NZS 3548 Class A (Australia), and VCCI Class A (Japan) with UTP17


EN55022 Class B (Europe), CISPR22 Class B (International), AS/NZS 3548 Class B, and VCCI18 Class B (Japan) with FTP19 cables

1NMP = network management processor

2DRAM = dynamic random-access memory

3NVRAM = nonvolatile random-access memory

4Btus = British thermal units

5lfm = linear feet per minute

6EMI = electromagnetic interference

7UL = Underwriters Laboratory

8CSA = Canadian Standards Association

9EN = European Norm

10IEC = International Electrotechnical Commission

11TS = Technical Specification

12AS/NZS = Standards Australia/Standards New Zealand

13CE = European Compliance

14FCC = Federal Communications Commission

15CFR = Code of Federal Regulations

16ICES = International Commerce Exchange Systems

17UTP = unshielded twisted-pair

18VCCI = Voluntary Control Council for Information Technology Equipment

19FTP = foil twisted-pair


hometocprevnextglossaryfeedbacksearchhelp
Posted: Sat Jan 18 13:25:53 PST 2003
All contents are Copyright © 1992--2002 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.