cc/td/doc/product/lan/cat4000/12_2_13t
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Using Loss Plan Defaults

Using Loss Plan Defaults

This appendix describes the loss plan defaults on the Cisco Catalyst 4000 Access Gateway Module (AGM).

Default Loss and Gain Values

When the CLI indicates the default Transmit (T) Input gain / Receive (R) output loss pads is 0 dB, the actual level for each of the VIC modules is:

Transmission Loss Plan

This system does not have pre-configured transmission loss plan settings. Therefore, it is important to set the loss plan for your network with the fixed loss pads on each VIC module. Use the following commands to set the loss plan for your network:

Command Purpose

input gain value

Specifies in decibels the amount of gain to be inserted at the receiver side of the interface. Acceptable values are from -6 to 14.

output attenuation value

Specifies in decibels the amount of attenuation at the transmit side of the interface. Acceptable values are from 0 to 14.

For North American private network, see draft PN-4819 (to be published as TIA/EIA/TSB-122).


hometocprevnextglossaryfeedbacksearchhelp
Posted: Thu Dec 19 10:05:12 PST 2002
All contents are Copyright © 1992--2002 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.