Caution After downloading the new software you must reset the switch. The Catalyst 3920 is not operational while it is resetting. Before starting this procedure, make sure the network will not be effected. |
The download procedures depend on the download method you choose. This chapter provides information about the following:
When using TFTP to update the Catalyst 3920 software, remember the following:
Step 1 Copy the binary file cat3900-main-gz.x-y-z.bin from CCO to the TFTP server and prepare the TFTP server.
Step 2 If you have not already done so, start a console session as described in the "Planning for Configuration and Management" chapter.
Step 3 Select Download/Upload on the Main Menu. The Download/Upload panel (Figure 9-1) is displayed.
Step 4 Select TFTP Download/Upload. The TFTP Download/Upload panel (Figure 9-2) is displayed.
Step 5 Fill in the following fields:
Step 6 Select Main Image Download. The Main Image Download panel (Figure 9-3) is displayed.
Step 7 Specify the path and filename as it exists on the TFTP server.
Step 8 Select Execute Main Image Network Download.
Step 9 If the Catalyst 3920 is participating in a stack, you will be prompted to specify whether you want to download the new software to a single switch or to the entire stack.
Step 10 Enter Y or N to confirm the download when the following message is displayed:
Please confirm new code download via network (Y or N):
Step 11 Press Enter when you see the message:
Download complete - reset switch to activate new software.
Press <Enter> to continue......
Step 12 Reset the Catalyst 3920 to activate the new code by selecting Reset on the Main Menu panel or by pressing the Reset button.
Step 1 If you have not already done so, start a console session as described in the section "Planning for Configuration and Management."
Step 2 Select Download/Upload on the Main Menu. The Download/Upload panel (Figure 9-1) is displayed.
Step 3 Select TFTP Download/Upload. The TFTP Download/Upload panel (Figure 9-2) is displayed.
Step 4 Fill in the following fields:
Step 5 Select the desired option.
To store the current configuration on the TFTP server, do the following:
To retrieve configuration information that has been stored on a TFTP server:
Step 6 Confirm the download or upload.
Step 7 Press Enter when you see the message:
Download complete - reset switch to activate new software.
Press <Enter> to continue......
Step 8 Reset the Catalyst 3920 to activate the new code by selecting the Reset option on the Main Menu panel or by pressing the Reset button.
Step 1 Insert the upgrade disk in your terminal drive.
Step 2 If you have not already done so, start a console session as described in the "Planning for Configuration and Management" chapter.
Step 3 Select Download/Upload on the Main Menu. The Download/Upload panel (Figure 9-1) is displayed.
Step 4 Select Serial Link Download. The Serial Link Download panel (Figure 9-6) is displayed.
Step 5 Select Main Image Download.
Step 6 Confirm the download. The download takes approximately 12 minutes at 9600 baud.
When the download is complete, the following messages appear:
Console: Beginning Xmodem download of main image
Console: Waiting for binary file.... Done
Console: Preparing Flash....Done.
Console: Saving Main Image into Flash...Done
Please confirm switch reset (Y or N):
Step 7 Enter Y to confirm the reset. The procedure is complete.
This section provides information on initiating the download procedure with the System Request Menu.
Follow these steps to begin a software upgrade:
Step 1 If you have not already done so, start a console session as described in the "Planning for Configuration and Management" chapter and advance to the Copyright panel.
Step 2 Press the System Request button (SYSREQ). The System Request Menu is displayed.
Step 3 Select your download option from the console.
Step 4 The following messages appear:
SYSREQ: Beginning Xmodem download of main (or boot) image
SYSREQ: Waiting for binary file....
Step 5 Use a terminal emulator program on your PC to download the binary file using Xmodem protocol. The download takes approximately 12 minutes at 9600 baud.
When the download is complete, the following messages appear:
SYSREQ: Beginning Xmodem download of main image
SYSREQ: Waiting for binary file.... Done
SYSREQ: Preparing Flash....Done.
SYSREQ: Saving Main Image into Flash...Done
SYSREQ: Press any key to return to System Request menu.
Step 6 Once the download is complete, press any key.
Step 7 On the System Request Menu, select Reset the system to reset the Catalyst 3920.
Posted: Tue Oct 12 13:45:17 PDT 1999