cc/td/doc/product/lan/cat3900
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Physical Specifications

Physical Specifications

This appendix provides information about the following:

Switch Physical Specifications

This section lists the power requirements, acceptable operating parameters, and physical dimensions for the base Catalyst 3900 Token Ring Switch.

Power Requirements

The Catalyst 3900's auto-ranging power supply operates on line voltage in the range of 90 to 264 VAC (auto-sensing) and 47 to 63 Hz, 150 Watts maximum. An appropriate power cord for the country of installation is shipped with the Catalyst 3900.

Operating Environment

Table D-1 lists the operating parameters for a Catalyst 3900.


Table D-1: Catalyst 3900 Operating Parameters
Characteristic Value or Range

Operating temperature

50° F to 104° F (10° C to 40° C)

Operating relative humidity

8% to 80%

Maximum wet-bulb temperature

81° F (27° C)

Thermal dissipation

150 watts (maximum); 512 Btu/hr

Electrical power

1.5 A at 115V; 0.75 A at 230V

Leakage/starting

Current less than 3.5 mA/15 amperes/half cycle

Physical Dimensions

Table D-2 lists the physical dimensions of a Catalyst 3900.


Table D-2: Catalyst 3900 Physical Dimensions
Physical Feature Dimension

Rack mounted width

19 in. (482.6 mm)

Standalone width

17.38 in. (441.45 mm)

Depth

15.25 in. (387.35 mm)

Height

3.4 in. (86.36 mm)

Weight

16 lbs (7.26 kg)


Note Rack mount brackets and mounting hardware are included with the unit.

Stack Port Module Physical Specifications

Table D-3 lists the power requirements of the stack port module.


Table D-3:

Electrical power

8 watts maximum (at 5V DC Æ5%)

Stack Port Module Power Requirements

Table D-4 lists the operating parameters for the stack port module.


Table D-4: Stack Port Operating Parameters

Temperature

50° F to 104° F (10° C to 40° C)

Relative humidity

8% to 80%

Maximum wet-bulb temperature

81° F (27° C)

Calorific value

27 Btu/hr (7 kcal/hr)

Table D-5 lists the physical dimensions of the stack port module.


Table D-5: Stack Port Module Physical Dimensions

Width

170 mm (6.7 in.)

Depth

214 mm (8.4 in.)

Height

25 mm (1 in.)

Fiber Token Ring Module Physical Specifications

Table D-6 lists the power requirements of the fiber module.


Table D-6:

Electrical power

20 watts

Fiber Module Power Requirements

Table D-7 lists the operating parameters for the fiber Token Ring module.


Table D-7: Fiber Module Operating Parameters

Temperature

50° F to 104° F (10° C to 40° C)

Relative humidity

8% to 80%

Maximum wet-bulb temperature

81° F (27° C)

Table D-8 lists the physical dimensions of the fiber Token Ring module.


Table D-8: Fiber Module Physical Dimensions

Width

5.45 in. (138.4 mm)

Depth

8.06 in. (204.7 mm)

Height

1 in. (25.4 mm)

Weight

1 lb (.45 kg)

Table D-9 lists the optical power transmit and receive parameters of the fiber Token Ring module.


Table D-9: Fiber Module Transmit and Receive Parameters
Optical Power Minimum Typical Maximum

Transmit

-16.0 d

m (25.1 µ)

-14.5 d

m (35.5 µ)

-12.0 d

m (63.1 µ)

Receive

-31.0 d

m (0.8 µ)

-11.0 d

m (79.4 µ)

UTP/STP Token Ring Module Physical Specifications

Table D-10 lists the power requirements of the UTP/STP module.


Table D-10:

Electrical power

20 watts

UTP/STP Module Power Requirements

Table D-11 lists the operating parameters for the UTP/STP Token Ring module.


Table D-11: UTP/STP Module Operating Parameters

Temperature

50° F to 104° F (10° C to 40° C)

Relative humidity

8% to 80%

Maximum wet-bulb temperature

81° F (27° C)

Table D-8 lists the physical dimensions of the UTP/STP Token Ring module.


Table D-12: UTP/STP Module Physical Dimensions

Width

5.45 in. (138.4 mm)

Depth

8.06 in. (204.7 mm)

Height

1 in. (25.4 mm)

Weight

1 lb (.45 kg)

ATM Module Physical Specifications

Table D-13 lists the power requirements of the ATM module.


Table D-13:

Electrical power

5 amps at 5 volts DC or 25 watts

ATM Module Power Requirements

Table D-14 lists the operating parameters for the ATM module.


Table D-14: ATM Module Operating Parameters

Temperature

50° F to 104° F (10° C to 40° C)

Relative humidity

8% to 80%

Maximum wet-bulb temperature

81° F (27° C)

Table D-15 lists the physical dimensions of the ATM module.


Table D-15: ATM Module Physical Dimensions

Width

6.7 in. (170 mm.)

Depth

8.4 in. (214 mm)

Height

1 in. (25 mm.)

ISL Module Physical Specifications

Table D-16 lists the power requirements of the ISL module.


Table D-16: ISL Module Power Requirements

Power consumption

20 watts

Thermal dissipation

68 BTU/hr

Table D-17 describes the operating environment for the ISL module.


Table D-17: Operational Parameters

Temperature

50° F to 104° F (10° C to 40° C)

Relative humidity

8% to 80%

Maximum wet-bulb temperature

81° F (27° C)

Table D-18 lists the physical dimensions of the ISL module.


Table D-18: Physical Dimensions

Width

5.45 in. (138.4 mm)

Depth

8.06 in. (204.7 mm)

Height

1 in. (25.4 mm)

Weight

1 lb (.45 kg)

Table D-19 lists the electromagnetic interference (EMI) standards with which the ISL module complies.


Table D-19: EMI Standards

STP

FCC Class A (47 CFR, Part 15), ICES-003 Class A, EN 55022 Class A, CISPR22 Class A, AS/NZS 3548 Class A, and VCCI Class A

UTP

EN 55022 Class B; CISPR22 Class B, AS/NZS 3590 Class B, and VCCI Class B

Fiber

EN 55022 Class B; CISPR22 Class B, AS/NZS 3590 Class B, and VCCI Class B


Note The use of unshielded cables may cause undesired interference in situations where Class B emissions are required.


hometocprevnextglossaryfeedbacksearchhelp
Posted: Wed Oct 2 03:04:13 PDT 2002
All contents are Copyright © 1992--2002 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.