cc/td/doc/product/lan/cat2950/1219ea1
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Technical Specifications

Technical Specifications

Table A-1, Table A-2, Table A-3, and Table A-4 list the technical specifications for the Catalyst 2950 switches. Table A-5 and Table A-6 list the regulatory agency approvals.


Table A-1: Technical Specifications for Catalyst 2950-12, 2950-24, 2950C-24, 2950SX-24, and 2950T-24 Switches

Environmental Ranges

Operating temperature

32 to 113°F (0 to 45°C)

Storage temperature

-13 to 158°F (-25 to 70°C)

Operating humidity

10 to 85% (noncondensing)

Operating altitude

Up to 10,000 ft (3000 m)

Storage altitude

Up to 15,000 ft (4570 m)

Power Requirements

AC input voltage

100 to 127/200 to 240 VAC
(autoranging) 50 to 60 Hz

DC input voltages for the Cisco RPS 300 Redundant Power System (RPS)

+12V

@4.5A

Power consumption

30W (maximum)

102 Btus per hour

Physical Dimensions

Weight

6.5 lb (3 kg)

Dimensions
(H x W x D)

1.72 x 17.5 x 9.52 in.
(4.36 x 44.45 x 24.18 cm)


Table A-2: Technical Specifications for Catalyst 2950G-12-EI, 2950G-24-EI, and 2950G-48-EI Switches
Catalyst 2950G-12-EI and 2950G-24-EI Switches Catalyst 2950G-48-EI Switch

Environmental Ranges

Operating temperature

32 to 113°F
(0 to 45°C)

32 to 113°F
(0 to 45°C)

Storage temperature

-13 to 158°F
(-25 to 70°C)

-13 to 158°F
(-25 to 70°C)

Operating humidity

10 to 85% (noncondensing)

10 to 85% (noncondensing)

Operating altitude

Up to 10,000 ft (3000 m)

Up to 10,000 ft (3000 m)

Storage altitude

Up to 15,000 ft (4570 m)

Up to 15,000 ft (4570 m)

Power Requirements

AC input voltage

100 to 127/200
to 240 VAC (autoranging)
50 to 60 Hz

100 to 127/200
to 240 VAC (autoranging)
50 to 60 Hz

DC input voltage for the Cisco RPS 300

+12V

@4.5A

+12V

@4.5A

Power consumption

30W (maximum)

102 Btus per hour

45W (maximum)

154 Btus per hour

Physical Dimensions

Weight

6.5 lb (3 kg)

10.5 lb (4.8 kg)

Dimensions
(H x W x D)

1.72 x 17.5 x 9.52 in.
(4.36 x 44.45 x 24.18 cm)

1.72 x 17.5 x 13 in.
(4.36 x 44.45 x 33.02 cm)


Table A-3: Technical Specifications for Catalyst 2950G-24-EI-DC Switch

Environmental Ranges

Operating temperature

32 to 113°F (0 to 45°C)

Storage temperature

-13 to 158°F (-25 to 70°C)

Operating humidity

10 to 85% (noncondensing)

Operating altitude

Up to 10,000 ft (3000 m)

Storage altitude

Up to 15,000 ft (4570 m)

Power Requirements

Power consumption

30W

DC input voltage

-36 to -72 VDC

Wire gauge for power connection

18 AWG1 (6 AWG for protective earth)

Branch circuit protection

5A

Physical Dimensions

Weight

6.5 lb (3 kg)

Dimensions
(H x W x D)

1.72 x 17.5 x 9.52 in.
(4.36 x 44.45 x 24.18 cm)

1AWG = American Wire Gauge

Table A-4: Fiber-Port Specifications for Catalyst 2950C-24 and Catalyst 2950SX-24 Switches

Fiber-Port Power Levels

Catalyst 2950C-24

Catalyst 2950SX-24

Optical transmitter wavelength

1300 nm1

850 nm

Optical receiver sensitivity

-34.5 to 31.8 dBm2

-13.5 dBm

Optical transmitter power for 50/125-micron cabling

-23.5 to -14 dBm

-9.5 to -4 dBm

Optical transmitter power for 62.5/125-micron cabling

-20 to -14 dBm

-9.5 to -4 dBm

1nm = nanometers
2dBm = decibel milliwatt


Table A-5: Catalyst 2950 Switch Agency Approvals
Safety EMC

UL 60950/CSA 22.2 No. 950

FCC Part 15 Class A

IEC 60950/EN 60950

EN 55022: 1998 (CISPR22) Class A

AS/NZS 3260, TS001

EN 55024: 1998 (CISPR24)

CE

VCCI Class A

AS/NZS 3548 Class A

CE

CNS 13438 Class A

MIC

CLEI code


Table A-6: Catalyst 2950G-24-EI-DC Switch Agency Approvals
NEBS

Bellcore GR-1089-CORE

Bellcore GR-63-CORE

Bellcore SR-3580 Level 3


hometocprevnextglossaryfeedbacksearchhelp
Posted: Tue Sep 10 22:12:18 PDT 2002
All contents are Copyright © 1992--2002 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.