|
Table A-1, Table A-2, Table A-3, and Table A-4 list the technical specifications for the Catalyst 2950 switches. Table A-5 and Table A-6 list the regulatory agency approvals.
Environmental Ranges | ||
| Operating temperature | 32 to 113°F (0 to 45°C) |
| Storage temperature | -13 to 158°F (-25 to 70°C) |
| Operating humidity | 10 to 85% (noncondensing) |
| Operating altitude | Up to 10,000 ft (3000 m) |
| Storage altitude | Up to 15,000 ft (4570 m) |
Power Requirements | ||
| AC input voltage | 100 to 127/200 to 240 VAC |
| DC input voltages | +12V |
| Power consumption | 30W (maximum) 102 Btus per hour |
Physical Dimensions | ||
| Weight | 6.5 lb (3 kg) |
| Dimensions | 1.72 x 17.5 x 9.52 in. |
Catalyst 2950G-12-EI and 2950G-24-EI Switches | Catalyst 2950G-48-EI Switch | ||
---|---|---|---|
Environmental Ranges | |||
| Operating temperature | 32 to 113°F | 32 to 113°F |
| Storage temperature | -13 to 158°F | -13 to 158°F |
| Operating humidity | 10 to 85% (noncondensing) | 10 to 85% (noncondensing) |
| Operating altitude | Up to 10,000 ft (3000 m) | Up to 10,000 ft (3000 m) |
| Storage altitude | Up to 15,000 ft (4570 m) | Up to 15,000 ft (4570 m) |
Power Requirements | |||
| AC input voltage | 100 to 127/200 | 100 to 127/200 |
| DC input voltage | +12V | +12V |
| Power consumption | 30W (maximum) 102 Btus per hour | 45W (maximum) 154 Btus per hour |
Physical Dimensions | |||
| Weight | 6.5 lb (3 kg) | 10.5 lb (4.8 kg) |
| Dimensions | 1.72 x 17.5 x 9.52 in. | 1.72 x 17.5 x 13 in. |
Environmental Ranges | ||
| 32 to 113°F (0 to 45°C) | |
| Storage temperature | -13 to 158°F (-25 to 70°C) |
| 10 to 85% (noncondensing) | |
| Operating altitude | Up to 10,000 ft (3000 m) |
| Up to 15,000 ft (4570 m) | |
| Power consumption | 100W |
| DC input voltage | -36 to -72 VDC |
| Wire gauge for power connection | 12 or 14 AWG1 (6 AWG for protective earth) |
| Branch circuit protection | 5A |
Physical Dimensions | ||
| Weight | 6.5 lb (3 kg) |
| Dimensions | 1.72 x 17.5 x 9.52 in. |
1AWG = American Wire Gauge |
Fiber-Port Power Levels | ||
| Optical transmitter wavelength | 1300 nm1 |
| Optical receiver sensibility | -14 dBm2 |
| Optical transmitter power | -19 to -14 dBm |
| Transmit | -19 to -14 dBm |
1nm = nanometers 2dBm = decibel milliwatt |
Safety | EMC |
UL 1950/CSA 22.2 No. 950 | FCC Part 15 Class A |
IEC 60950/EN 60950 | EN 55022: 1998 (CISPR22) Class A |
AS/NZS 3260, TS001 | EN 55024: 1998 (CISPR24) |
CE | VCCI Class A |
| AS/NZS 3548 Class A |
| CE |
| CNS 13438 Class A |
| MIC |
NEBS |
Bellcore GR-1089-CORE |
Bellcore GR-63-CORE |
Posted: Mon Dec 17 18:37:05 PST 2001
All contents are Copyright © 1992--2001 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.