cc/td/doc/product/lan/cat2950/12114az
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Overview
Features
Front-Panel Description
Rear-Panel Description
Management Options

Overview


This chapter provides information about these topics:

Features

The Catalyst 2950 switches are a family of Ethernet switches that you can use to connect workstations and other network devices, such as servers, routers, and other switches. All models of the switch are cluster-capable, but only some models are stackable. You can use switches with Gigabit interface converter (GBIC) module slots to create switch stacks by using Gigastack GBICs. Some switch models can be deployed as backbone switches, aggregating 10BASE-T, 100BASE-TX, Gigabit Ethernet, and Long-Reach Ethernet (LRE) traffic from other switches and network devices. Refer to the switch software configuration guide for examples that show how you might deploy the switches in your network.

Figure 2-1 through Figure 2-12 show the Catalyst 2950 switches.

These are the switch features:


Note    Refer to the Catalyst 2950 LRE switch release notes for a list of supported SFP modules for the Catalyst 2950 LRE switches.

1000BASE-SX GBIC

1000BASE-LX/LH GBIC

1000BASE-ZX GBIC

1000BASE-T GBIC (model WS-5483)

Coarse Wave Division Multiplexer (CWDM) fiber-optic GBIC

GigaStack GBIC

Certain Cisco LRE customer premises equipment (CPE) devices are not supported by certain Catalyst 2950 LRE switches. In Table 2-1, Yes means that the CPE is supported by the switch; No means that the CPE is not supported by the switch.

Table 2-1   LRE Switch and CPE Compatibility Matrix

LRE Devices  Catalyst 2950ST-8 LRE  Catalyst 2950ST-24 LRE  Catalyst 2950ST-24 LRE 997 

Cisco 575 LRE CPE

Yes

Yes

No

Cisco 576 LRE 997 CPE

No

No

Yes

Cisco 585 LRE CPE

Yes

Yes

No

Front-Panel Description

The switch front panel contains the ports, the LEDs, and the Mode button.

Other than the Catalyst 2950ST-24 LRE 997 switch, the front panel of the Catalyst 2950 LRE switches also contain the console port and AC power connector. On the Catalyst 2950ST-24 LRE 997 switch, the front panel contains a DC power connector (also referred to as the terminal block header), a DC ground lug, and an RJ-45 console port.

For more information about the power connectors on the LRE switches, see the "Power Connectors" section. For more information on the console port on these switches, see the "Console Port" section.

Figure 2-1 to Figure 2-12 show the switches.


Figure 2-1   Catalyst 2950-12 Switch



Figure 2-2   Catalyst 2950-24 Switch



Figure 2-3   Catalyst 2950C-24 Switch



Figure 2-4   Catalyst 2950G-12-EI Switch



Figure 2-5   Catalyst 2950G-24-EI Switch



Figure 2-6   Catalyst 2950G-24-EI-DC Switch



Figure 2-7   Catalyst 2950G-48-EI Switch



Figure 2-8   Catalyst 2950ST-8 LRE Switch



Figure 2-9   Catalyst 2950ST-24 LRE Switch



Figure 2-10   Catalyst 2950ST-24 LRE 997 Switch



Figure 2-11   Catalyst 2950SX-24 Switch



Figure 2-12   Catalyst 2950T-24 Switch



Figure 2-13   Catalyst 2950SX-48-SI Switch



Figure 2-14   Catalyst 2950T-48-SI Switch


10/100 Ports

The 10/100 ports use RJ-45 connectors and twisted-pair cabling. The ports can connect to these devices:

The 10/100 ports can be explicitly set to operate in any combination of half duplex, full duplex, 10 Mbps, or 100 Mbps. They can also be set for speed and duplex autonegotiation, compliant with IEEE 802.3U. In all cases, the cable length from a switch to an attached device cannot exceed 328 feet (100 meters).

When set for autonegotiation, a port senses the speed and duplex settings of the attached device and advertises its own capabilities. If the attached device supports autonegotiation, the port negotiates the best connection (that is, the fastest line speed that both devices support and full-duplex transmission, if the attached device supports it) and configures itself accordingly.

10/100/1000 Ports

The 10/100/1000 ports on Catalyst 2950T-24, Catalyst 2950T-48-SI, and Catalyst 2950 LRE switches use RJ-45 connectors and twisted-pair cabling. The ports can connect to these devices:

The 10/100/1000 ports on the Catalyst 2950T-24 switch can be explicitly set to operate at 10, 100, or 1000 Mbps, but only in full-duplex mode. The 10/100/1000 ports on the Catalyst 2950T-48-SI and Catalyst 2950 LRE switches can be explicitly set to operate at 10 or 100 Mbps in full- or half-duplex mode or at 1000 Mbps in full-duplex mode.

The 10/100/1000 ports can also be set for speed autonegotiation, compliant with IEEE 802.3AB. In all cases, the cable length from a switch to an attached device cannot exceed 328 feet (100 meters).


Note   On the Catalyst 2950 LRE switches, the four input uplink ports are bundled as two logical ports, each consisting of a copper 10/100/1000 port and a fiber-optic SFP module slot, respectively.

Within each logical port, you can use only the copper or the fiber-optic port at one time. If a Catalyst 2950 LRE switch senses more than two connections for both logical ports, the switch chooses the fiber-optic connections over the copper connections in default operation.

See the "SFP Module Slots" section for more information on LRE uplink logical ports.

100BASE-FX and 1000BASE-SX Ports

The 100BASE-FX and 1000BASE-SX ports both use 50/125- or 62.5/125-micron multimode fiber-optic cabling. The 100BASE-FX ports operate only at 100 Mbps in full-duplex mode, and the 1000BASE-SX ports operate only at 1000 Mbps in full-duplex mode.

In full-duplex mode, the cable length from a 100BASE-FX port on a switch to an attached device cannot exceed 6562 feet (2 kilometers). The cable length from a 1000BASE-SX port on a switch to an attached device cannot exceed 1804 feet (550 meters).

You can connect a 100BASE-FX or 1000BASE-SX port to an SC or ST port on a target device by using one of the MT-RJ fiber-optic patch cables listed in Table 3-1. Use the Cisco part numbers in Table 3-1 to order the patch cables that you need.

LRE Port

The LRE port (shown in Figure 2-8) uses one RJ-21 connector to connect up to 24 Cisco LRE CPE devices through structured or unstructured wiring, such as existing telephone lines. The link between the LRE switch port and each CPE device can reach speeds of up to 15 Mbps (full duplex) over distances of up to 4921 feet (1500 meters).

Certain Catalyst 2950 LRE switches support certain Cisco LRE CPE devices. Table 2-1 shows which LRE switches support which CPE devices.

You can connect the Cisco 575 LRE CPE and Cisco 585 LRE CPE devices to LRE ports on the same Catalyst 2950ST-8 LRE or 2950ST-24 LRE switch. You can connect the Cisco 576 LRE CPE 997 device only to LRE ports on a Catalyst 2950ST-24 LRE 997 switch. You can hot swap the CPE devices without powering down the switch or disrupting the other switch ports.

The default mode for each LRE port is speed autosensing and half-duplex operation. For information about configuring the LRE ports, refer to the switch software configuration guide.

If telephone services, such as voice or an Integrated Services Digital Network (ISDN), use the same cabling as LRE traffic, the LRE port must be connected to the patch panel through a plain old telephone service (POTS) splitter. The splitter routes LRE data (high-frequency) and voice (low-frequency) traffic from the telephone line to the switch and private branch exchange (PBX) switch or public switched telephone network (PSTN).

If the other telephone services are connected through a PBX switch, a non-homologated POTS splitter, such as the Cisco LRE 48 POTS Splitter, can be used. The PBX routes voice traffic to private telephone networks and the PSTN. For more information about the Cisco LRE 48 POTS Splitter (PS-1M-LRE-48), refer to the Installation and Warranty Notes for the Cisco LRE 48 POTS Splitter.

For limitations and restrictions when you use a POTS splitter with the Catalyst 2950 LRE switches and Cisco LRE CPE, see the "Limitations and Restrictions with POTS Splitters" section.

If the installation does not have a PBX, a homologated POTS splitter is required to connect directly to the PSTN. For more information about homologated POTS splitters, contact your Cisco sales representative.

If a connection to a telephone network is not required, a splitter is not needed, and the switch can connect directly to the patch panel.

For more information about the Cisco LRE CPE devices, refer to the Cisco LRE CPE Hardware Installation Guide.

GBIC Module Ports

The GBIC module slots support these modules:

For more information about these GBIC modules, refer to your GBIC module documentation.

SFP Module Slots

On the Catalyst 2950 LRE switch, the SFP module slots support the SFP modules listed in the Catalyst 2950 LRE switch release notes.

The Catalyst 2950 LRE switch has four physical input ports that are logically bundled as two ports. Each logical port consists of a copper 10/100/1000 port and a fiber-optic SFP module slot. These ports appear as a vertical column on the front panel and are labeled Uplink Port 1 and Uplink Port 2.

Within each port, you can use only one of the two physical ports, either the SFP module port or the 10/100/1000 port. For example, you can connect to either the SFP module port or the 10/100/1000 port on Uplink Port 1. If you connect to both, in default operation, the SFP module port has priority over the 10/100/1000 port. Using this example, a valid configuration would be connecting to the fiber-optic port on Uplink Port 1 and the copper port on Uplink Port 2.


Note   By using the media-type {sfp | rj45 | auto-select} interface configuration command at the CLI, you can configure the Catalyst 2950 LRE switch so that the SFP module port does not take precedence over the 10/100/1000 port. In that scenario, whichever media type establishes a link first has precedence over the other.

For more information about the media-type {sfp | rj45 | auto-select} command, refer to the switch command reference.

SFP Modules

The LRE switches use Ethernet SFP modules to establish uplink connections to other devices. The SFP modules are inserted into SFP module slots on the front of the Catalyst 2950 LRE switches. These transceiver modules are field-replaceable.

You use fiber-optic cables with LC or MT-RJ connectors to connect to fiber-optic SFP modules. You use Category 5 cable with RJ-45 connectors to connect to 1000BASE-T SFP modules.

The SFP modules support nominal wavelengths from 850 to 1550 nanometers (nm). Refer to the Catalyst 2950 LRE switch release notes for the list of supported SFPs.

When determining where to place the switch, be sure to observe these requirements:

Table 2-2   Fiber-Optic SFP Module Port Cabling Specifications

SFP Module  Wavelength (nanometers)  Fiber Type  Core Size (micron)  Modal Bandwidth (MHz/km)  Cable Distance 

1000BASE-SX

850

MMF

62.5
62.5
50
50

160
200
400
500

722 feet (220 m)
902 feet (275 m)
1640 feet (500 m)
1804 feet (550 m)

1000BASE-LX/LH

1300

MMF1

SMF

62.5
50
50
9/10

500
400
500

1804 feet (550 m)
1804 feet (550 m)
1804 feet (550 m)
32,810 feet (10 km)

1000BASE-ZX

1550

SMF

9/10

43.4 to 62 miles (70 to 100 km)2

A mode-conditioning patch cord is required. Using an ordinary patch cord with MMF, 1000BASE-LX/LH SFP modules, and a short link distance can cause transceiver saturation, resulting in an elevated bit error rate (BER). When using the LX/LH SFP module with 62.5-micron diameter MMF, you must also install a mode-conditioning patch cord between the SFP module and the MMF cable on both the sending and receiving ends of the link. The mode-conditioning patch cord is required for link distances greater than 984 feet (300 m).

1000BASE-ZX SFP modules can send up to 62 miles (100 km) by using dispersion-shifted SMF or low-attenuation SMF; the distance depends on the fiber quality, the number of splices, and the connectors.


Note   When using shorter distances of single-mode fiber cable, you might need to insert an inline optical attenuator in the link to avoid overloading the receiver.

When the fiber-optic cable span is less than15.43 miles (25 km), you should insert a 5-decibel (dB) or 10-dB inline optical attenuator between the fiber-optic cable plant and the receiving port on the 1000BASE-ZX SFP module at each end of the link.

Use only Cisco-approved SFP modules on the Catalyst 2950 LRE switch.


Note   Cisco-approved SFP modules have a serial EEPROM that contains the module serial number, the vendor name and ID, a unique security code, and cyclic redundancy check (CRC). When an SFP module is inserted in the switch, the switch software reads the EEPROM to check the serial number, vendor name, and vendor ID and recomputes the security code and CRC. If the serial number, the vendor name or ID, security code, or CRC is invalid, the switch places the interface in an error-disabled state.


Note   If you are using a non-Cisco approved SFP module, remove the module from the switch, and replace it with a Cisco-approved module.

For more information about these SFP modules, refer to your SFP module documentation.

LEDs

You can use the LEDs to monitor switch activity and performance. The locations and numbers of the LEDs vary among switch models. The location of the Mode button that you use to select the port mode also varies by model. See these figures:

All of the LEDs described in this section (except the utilization meter [UTIL]) are visible in the Cluster Management Suite (CMS). The switch software configuration guide describes how to use CMS to configure and to monitor individual switches and switch clusters.


Figure 2-15   LEDs on Catalyst 2950-12, 2950-24, 2950C-24, 2950SX-24, and 2950T-24 Switches



Figure 2-16   LEDs on Catalyst 2950G-12-EI, 2950G-24-EI, and 2950G-24-EI-DC Switches



Figure 2-17   LEDs on Catalyst 2950G-48-EI, 2950SX-48-SI, and 2950T-48-SI Switches



Figure 2-18   LEDs on Catalyst 2950ST-8 LRE and 2950ST-24 LRE Switches



Figure 2-19   LEDs on Catalyst 2950ST-24 LRE 997 Switches


System LED

The system LED shows whether the system is receiving power and functioning properly. Table 2-3 lists the LED colors and meanings.

Table 2-3   System LED

Color  System Status 

Off

System is not powered up.

Green

System is operating normally.

Amber

System is receiving power but is not functioning properly.

For information about the system LED colors during the power-on self-test (POST), see the "Connecting to a Power Source" section.

RPS LED

The RPS LED shows the RPS status. Table 2-4 lists the LED colors and meanings.

Table 2-4   RPS LED

Color  RPS Status 

Off

RPS is off or is not installed.

Solid green

RPS is connected and ready to provide back-up power.

Flashing green

RPS is connected but is unavailable because it is providing power to another device (redundancy has been allocated to a neighboring device).

Solid amber

RPS is in standby mode or in a fault condition. Press the Standby/Active button on the RPS, and the LED should turn green. If it does not, the RPS fan could have failed. Contact Cisco Systems.

Flashing amber

The internal power supply in a switch has failed, and the RPS is providing power to the switch (redundancy has been allocated to this device).

For more information about the Cisco RPS 300, refer to the Cisco RPS 300 Redundant Power System Hardware Installation Guide.

For more information about the Cisco RPS 675, refer to the Cisco RPS 675 Redundant Power System Hardware Installation Guide.

Port Mode and Port Status LEDs

To select or change the port mode, press the Mode button (see Figure 2-15 to Figure 2-18) to highlight the mode that you want. Release the button to enable the highlighted mode.

Each port has a port status LED, also called a port LED. These LEDs, as a group or individually, display information about the switch and the individual ports. The port modes (see Table 2-5) determine the type of information displayed.

Table 2-5   Port Mode LEDs

Mode LED  Port Mode  Description 

STAT

Port status

The port status. This is the default mode.

UTIL1

Switch utilization

The bandwidth in use by the switch.

DUPLX

Port duplex mode

The port duplex mode: half duplex or full duplex.

SPEED

Port speed

The port operating speed: 10 or 100 Mbps for 10/100 ports and 10, 100, or 1000 Mbps for 10/100/1000 ports.

A Catalyst 2950 LRE switch does not have a UTIL or a DUPLX LED.

When you change the port mode, the meanings of the port LED colors change. Table 2-6 explains how to interpret these colors for the non-LRE switches. Table 2-7 explains how to interpret the colors for the LRE switches. The port LEDs are off when the MODE is set to SPEED.

Table 2-6   Meaning of Port LED Colors in Different Modes for Non-LRE Switches

Port Mode  Color  Meaning 

STAT (port status)

Off

No link.

Solid green

Link present.

Flashing green

Activity. Port is sending or receiving data.

Alternating green-amber

Link fault. Error frames can affect connectivity, and errors such as excessive collisions, CRC errors, and alignment and jabber errors are monitored for a link-fault indication.

Solid amber

Port is not forwarding. Port was disabled by management, an address violation, or Spanning Tree Protocol (STP).

Note After a port is reconfigured, the port LED can remain amber for up to 30 seconds while STP checks the switch for possible loops.

UTIL (utilization)

Green

The current backplane utilization that is displayed over the amber LED background on a logarithmic scale.

Amber

The maximum backplane utilization since the switch was powered on.

Green and amber

See Figure 2-20 to Figure 2-24 for details.

Note If the current utilization exceeds the maximum utilization, the maximum utilization is automatically updated.

DUPLX

(half or full duplex)

Off

Port is operating in half duplex.

Green

Port is operating in full duplex.

SPEED

10/100 ports

Off

Port is operating at 10 Mbps.

Green

Port is operating at 100 Mbps.

10/100/1000 ports

Off

Port is operating at 10 Mbps.

Green

Port is operating at 100 Mbps.

Flashing green

Port is operating at 1000 Mbps.

1000BASE-X GBIC module ports

Off

Port is not operating.

Green

Port is operating at 1000 Mbps.

Table 2-7   Meaning of Port LED Colors in Different Modes for the LRE Switches

Port Mode  Color  Meaning 

STAT (port status)

Off

No link.

Solid green

Link present.

Note The LRE port LED turns green approximately 30 seconds after the LRE port detects a connection to an LRE CPE.

Flashing green

Activity. Port is sending or receiving data.

Alternating green-amber

Link fault. Error frames can affect connectivity, and errors such as excessive collisions, CRC errors, and alignment and jabber errors are monitored for a link-fault indication.

Solid amber

A link is established on a nonassigned LRE profile, or a port is not forwarding.

If a port is not forwarding, it was disabled by management, an address violation, or STP.

Note After a port is reconfigured, the port LED can remain amber for up to 30 seconds while STP checks the switch for possible loops.

DUPLX

(half or full duplex)

Off

Port is operating in half duplex.

Green

Port is operating in full duplex.

SPEED

10/100/1000 ports1 2

Off

Port is operating at 10 Mbps.

Green

Port is operating at 100 Mbps.

Flashing green

Port is operating at 1000 Mbps.

SFP modules1 2

Off

Port is operating at 10 Mbps

Green

Port is operating at 100 Mbps

Flashing green

Port is operating at 1000 Mbps

On an LRE switch, the LEDs for Uplink Port 1 and Uplink Port 2 correspond either to the SFP module port or to the 10/100/1000 port, depending on which is active.

If an LRE switch senses connections to both ports, by default, the switch chooses the fiber-optic connection over the copper connection.

For more information about GBIC LEDs, refer to your GBIC module documentation.

Figure 2-20 to Figure 2-24 show the bandwidth utilization percentages displayed by the right-most LEDs.


Note   The Catalyst 2950 LRE switch LEDs do not give utilization status.

If all LEDs on a Catalyst 2950-12, 2950-24, 2950C-24, 2950SX-24, or 2950T-24 switch are green (no amber showing), the switch is using 50 percent or more of the total bandwidth. If the far-right LED is off, the switch is using more than 25 but less than 50 percent of the total bandwidth, and so on. If only the far-left LED is green, the switch is using less than 0.0488 percent of the total bandwidth. (See Figure 2-20 and Figure 2-21.)


Figure 2-20   Bandwidth Utilization on Catalyst 2950-12 Switches



Figure 2-21   Bandwidth Utilization on Catalyst 2950-24, 2950C-24, 2950SX-24, and 2950T-24 Switches


If all LEDs on a Catalyst 2950G-12-EI switch are green (no amber showing), the switch is using 50 percent or more of the total bandwidth. If the LED for GBIC module slot 2 is off, the switch is using more than 25 but less than 50 percent of the total bandwidth. If LEDs for both GBIC module slots are off, the switch is using less than 25 percent of the total bandwidth, and so on. (See Figure 2-22.)


Figure 2-22   Bandwidth Utilization on Catalyst 2950G-12-EI Switches


If all LEDs on a Catalyst 2950G-24-EI or 2950G-24-EI-DC switch are green (no amber showing), the switch is using 50 percent or more of the total bandwidth. If the LED for GBIC module slot 2 is off, the switch is using more than 25 but less than 50 percent of the total bandwidth. If LEDs for both GBIC module slots are off, the switch is using less than 25 percent of the total bandwidth, and so on. (See Figure 2-23.)


Figure 2-23   Bandwidth Utilization on Catalyst 2950G-24-EI and 2950G-24-EI-DC Switches


If all LEDs on a Catalyst 2950G-48-EI, 2950SX-48-SI, or 2950T-48-SI switch are green, the switch is using 50 percent or more of the total bandwidth. If the LED for GBIC module slot 2 is off, the switch is using more than 25 but less than 50 percent of the total bandwidth. If LEDs for both GBIC module slots are off, the switch is using less than 25 percent of the total bandwidth, and so on. (See Figure 2-24.)


Figure 2-24   Bandwidth Utilization on Catalyst 2950G-48-EI, 2950SX-48-SI, and 2950T-48-SI Switches


Rear-Panel Description

Other than the Catalyst 2950G-24-EI-DC switch and the Catalyst 2950 LRE switches, the rear panel of a Catalyst 2950 switch has an AC power connector, an RPS connector, and an RJ-45 console port. (See Figure 2-25 and Figure 2-26.)

The rear panel of the Catalyst 2950G-24-EI-DC switch has a DC power connector (also referred to as the terminal block header), a DC ground lug, an RPS connector, and an RJ-45 console port. (See Figure 2-27.)

The rear panel of the Catalyst 2950ST-8 LRE, 2950ST-24 LRE, and 2950ST-24 LRE 997 switches has only an RPS connector. (See Figure 2-28.)


Figure 2-25   Catalyst 2950 Switch Rear Panel



Figure 2-26   Catalyst 2950G-48-EI, Catalyst 2950SX-48-SI, and Catalyst 2950T-48-SI Switch Rear Panel



Figure 2-27   Catalyst 2950G-24-EI-DC Switch Rear Panel



Figure 2-28   Catalyst 2950ST-8 LRE Switch, Catalyst 2950ST-24 LRE, and Catalyst 2950ST-24 LRE 997 Switch Rear Panel


Power Connectors

You can provide power to a switch by using the AC internal power supply, the DC-input power source, or the Cisco RPS.

Internal Power Supply Connector

The internal AC power supply is an autoranging unit that supports input voltages between 100 and 240 VAC. Other than for the Catalyst 2950G-24-EI-DC and the Catalyst 2950ST-24 LRE 997 switches, use the supplied AC power cord to connect the AC power connector to an AC power outlet.


Note   The AC power connector is on the front panel of the Catalyst 2950ST-8 LRE and Catalyst 2950ST-24 LRE switches.

You can order these L-shaped AC power cords from your Cisco sales representative:

DC Power Connector

The Catalyst 2950G-24-EI-DC and Catalyst 2950ST-24 LRE 997 switches have an internal DC-power converter. It has dual feeds (A and B) that are diode-OR-ed into a single power block. For installation instructions, see "Connecting to DC Power."


Caution   You must connect the Catalyst 2950G-24-EI-DC and 2950ST-24 LRE 997 switches only to a DC-input power source that has an input supply voltage from -36 to -72 VDC. If the supply voltage is not in this range, the switch might not operate properly or might be damaged.

Cisco RPS Connector

Specific Cisco RPS models support specific Catalyst 2950 switches:

Cisco RPS 300

The Cisco RPS 300 has two output levels: -48V and 12V with a total maximum output power of 300W. Use the supplied RPS connector cable to connect the RPS to the switch.


Warning Attach only the Cisco RPS 300 (model PWR300-AC-RPS-N1) to the RPS receptacle.

The RPS is a 300W redundant power system that can support six external network devices and provides DC power to one failed device at a time. It automatically senses when the internal power supply of a connected device fails and provides power to that device, preventing loss of network traffic.

For more information, refer to the Cisco RPS 300 documentation.

Cisco RPS 675

The Cisco RPS 675 has two output levels: -48V and 12V with a total maximum output power of 675W. Use the supplied RPS connector cable to connect the RPS to the switch.


Warning Attach only the Cisco RPS 675 (model PWR675-AC-RPS-N1=) to the RPS receptacle.

The RPS is a 675W redundant power system that can support six external network devices and provides DC power to one failed device at a time. It automatically senses when the internal power supply of a connected device fails and provides power to that device, preventing loss of network traffic.

For more information, refer to the Cisco RPS 675 documentation.

Console Port

You can connect a switch to a PC through the console port and the supplied RJ-45-to-DB-9 adapter cable. If you want to connect a switch to a terminal, you need to provide an RJ-45-to-DB-25 female DTE adapter. You can order a kit (part number ACS-DSBUASYN=) with that adapter from Cisco. For console-port and adapter-pinout information, see the "Cable and Adapter Specifications" section.

Management Options

Catalyst 2950 switches offer these management options:

CMS is made up of three web-based applications that you use to manage switches. You can use Cluster Builder, which includes Cluster View, and Cluster Manager to create, configure, and monitor switch clusters. You can also use Device Manager to manage individual and standalone switches. For more information, refer to the switch software configuration guide and the CMS online help.

You can manage switches by using command-line entries. To access the CLI, connect a PC or a terminal directly to the console port on the switch. If the switch is attached to your network, you can use a Telnet connection to manage the switch from a remote location. For more information, refer to the switch command reference.

For quick setup instructions that use the CLI, go to "Configuring the Switch with the CLI-Based Setup Program."

You can use the CiscoView device-management application to set configuration parameters and to view switch status and performance information. This application, which you purchase separately, can be a standalone application or part of an Simple Network Management Protocol (SNMP) network-management platform. For more information, refer to the documentation that came with your CiscoView application.

You can manage switches by using an SNMP-compatible management station running platforms such as HP OpenView and SunNet Manager. The switch supports a comprehensive set of management information base (MIB) extensions and MIB II, the IEEE 802.1D bridge MIB, and four Remote Monitoring (RMON) groups. For more information, refer to the documentation that came with your SNMP application.

The Cisco IE200 Series Configuration Registrar is a network management device that works with embedded Cisco Networking Services (CNS) agents in the switch software. You can automate initial configurations and configuration updates by generating switch-specific configuration changes, sending them to the switch, executing the configuration change, and logging the results. For more information, refer to the switch software configuration guide and the documentation that came with your application.