This chapter describes how to use the Command Line Interface(CLI) to configure such functions as IP addressing and SNMP management for the Catalyst 2900. An IP address must be assigned if you need to use Telnet to connect to the switch or use SNMP network management for the switch. Up to eight simultaneous Telnet sessions are possible. If your Telnet station or SNMP network management workstation is on a different network from the switch, a static routing table entry must also be added to the routing table. Use the set ip route command to set the static routing table entry.
The Catalyst 2900 features you can customize have default values that will most likely suit your environment, and you will probably not need to change them. The default values of these features are set as follows:
The section listed below describes how to perform the initial configuration on the Catalyst 2900.
You configure the switch through the CLI interface using three basic types of commands: set, show, and clear. Use the set commands to establish switch parameters. After each set command, use the show command to verify that you have entered the correct values and configured the switch correctly. If you make errors, use the set or clear command to overwrite or erase the parameter.
For a list of available commands, type set help, show help, or clear help. To display the command usage, type the command and the word help, as the following example shows:
Console> (enable) set spantree hello help
Usage: set spantree hello <interval> [vlan]
(interval = 1..10, vlan = 1..1000)
Refer to the end of Chapter 4, "Configuring Ethernet and Fast Ethernet Software," for an example of a single switch configuration.
Before you can begin your configuration, you will need the following information:
After installing and connecting the switch, perform the following steps to start up and access the switch. (Refer to the Catalyst 2900 User Guide publication for details about how to install and connect the Catalyst 2900 to a terminal.)
Task | Command |
---|---|
Turn ON the power to the switch and the console terminal. The information shown in Figure 3-1 appears on the screen. | None |
Access the console port using the console terminal. | None |
At the Enter password prompt, press Return. | None |
Enter privileged mode. | enable |
At the Enter password prompt, press Return. | None |
BOOTROM Version 1.1, Dated May 22 1995 15:17:09
Boot date: 05/22/95 BOOT time: 15:17:09
Executing from RAM
Cisco Systems Console
Sending RARP request with address 00:40:0b:a0:05:b8
Sending bootp request with address 00:40:0b:a0:05:b8
Sending RARP request with address 00:40:0b:a0:05:b8
Sending bootp request with address 00:40:0b:a0:05:b8
Sending RARP request with address 00:40:0b:a0:05:b8
Sending bootp request with address 00:40:0b:a0:05:b8
Sending RARP request with address 00:40:0b:a0:05:b8
Sending bootp request with address 00:40:0b:a0:05:b8
Sending RARP request with address 00:40:0b:a0:05:b8
Sending bootp request with address 00:40:0b:a0:05:b8
Sending RARP request with address 00:40:0b:a0:05:b8
Sending bootp request with address 00:40:0b:a0:05:b8
Sending RARP request with address 00:40:0b:a0:05:b8
Sending bootp request with address 00:40:0b:a0:05:b8
Sending RARP request with address 00:40:0b:a0:05:b8
Sending bootp request with address 00:40:0b:a0:05:b8
Sending RARP request with address 00:40:0b:a0:05:b8
Sending bootp request with address 00:40:0b:a0:05:b8
Sending RARP request with address 00:40:0b:a0:05:b8
Sending bootp request with address 00:40:0b:a0:05:b8
No bootp or rarp response received
Console>
Console> enable
Enter password:
Console> (enable)
Although not required, several system parameters should be set as part of the initial system setup. To set the system parameters, perform the following steps in privileged mode:
Task | Command |
---|---|
Set the system contact. | set system contact contact_string |
Set the system location string. | set system location location_string |
Set the system name. | set system name name_string |
Set the system clock. | set time day_of_week mm/dd/yy hh:mm:ss |
Set the system prompt. | set prompt prompt_string |
Set password protection for accessing the command line in normal mode. | set password |
Set password protection for accessing the command line in privileged mode. | set enablepass |
To set the interface type, perform the following steps in privileged mode:
Task | Command |
---|---|
If you are using a local network connection to the console port, set the logical port sc0. | set interface sc0 up
set interface sc0 ip_address [netmask [broadcast]] |
If you are using a SLIP connection to the console port, set the slip port sl0. Figure 3-2 for an example. | set interface sl0 up
set interface slip_address dest_address |
Configure static routes. For example, you need to configure static routes if your Telnet station or SNMP network management workstation is on a different network from the switch. | set ip route destination gateway [metric] |
Configure a default route, if desired. Refer to the set interface and set ip route Command Example 3-2. | set ip route destination gateway metric |
Check the status of the configuration of the switch. See Figure 3-3 for an example. Refer to the set interface and set ip route Command Example 3-3. | show interface |
Display the route table entries of the configuration. See Figure 3-4 for an example. | show ip route |
Console> (enable) set interface sc0 up
Interface sc0 administratively up.
Console> (enable) set interface sc0 192.200.11.44 255.255.255.0 \
192.200.11.255
Interface sc0 IP address and netmask set.
Console> (enable) set interface sl0 up
Interface sl0 administratively up.
Console> (enable) set interface sl0 192.200.10.45 192.200.10.103
Interface sl0 SLIP and destination address set.
Console> (enable) set interface sc0 5
Interface sc0 vlan set.
Console> (enable) set ip route default 192.122.173.42 1
Route added.
The default configuration is as follows:
Console> (enable) show interface
sl0: flags=10<DOWN,POINTOPOINT>
vlan1 inet 0.0.0.0 netmask 0.0.0.0 broadcast 0.0.0.0
sc0: flags=863<UP,BROADCAST,RUNNING>
inet 0.0.0.0 netmask 0.0.0.0 broadcast 0.0.0.0
Console> (enable)
After the set interface command has been executed, the show interface command shows the following configuration:
Console> (enable) show interface
sl0: flags=10<DOWN,POINTOPOINT>
inet 192.200.10.45 netmask 192.200.10.103 broadcast 192.200.10.103
sc0: flags=863<UP,BROADCAST,RUNNING>
inet 192.200.11.44 netmask 255.255.255.0 broadcast 192.200.11.255
Console> (enable)
Console> (enable) show ip route
Redirect
--------
enabled
Destination Gateway Flags Use Interface
--------------- --------------- ------ ---------- ---------
default 192.22.74.102 UG 59444 sc0
192.22.74.0 192.22.74.223 U 5 sc0
Console> (enable)
To configure the console port for SLIP, perform the following steps:
Task | Command |
---|---|
Access the switch from a remote host with Telnet. | None |
Set the IP address of the console port. | set interface slip_address dest_address |
Enable the SLIP for the console port. | slip attach |
IP address information can be set using BOOTP protocol. You can configure a BOOTP server with the MAC and IP addresses of the switch. When the switch boots, it automatically retrieves the IP address from the BOOTP server.
The switch performs a BOOTP request only if the current IP address is set to 0.0.0.0. (This is the default for a new switch or a switch that has had its configuration file cleared using the clear config all command.)
To configure a workstation as a BOOTP server, you must determine the MAC address of the switch and add that MAC address to the BOOTP configuration file on the server. The following steps provide an example of creating a BOOTP server on a Sun workstation:
Task | Command |
---|---|
Install the BOOTP server code on the workstation, if it is not already installed. | None |
Obtain the first address in the MAC address range for VLAN 1 in module 1 (the supervisor module). Figure 3-5 shows an example of the show module command output. Choose the last address in the range on line 1 under the MAC-Address(es) heading. In this example, the correct MAC address shown for module 1 is 00-04-0b090-b5-00. | show module |
Add an entry in the BOOTP configuration file (usually /usr/etc/bootptab) for each Catalyst 2900. Press Return after each entry to create a blank line between each entry. In the example in Figure 3-6, ht is hardware type, ha is hardware address (use the first address in the MAC address range), sm is the network subnet mask, and ip is IP address. | None |
Console> show module
Mod Module-Name Ports Module-Type Model Serial-Num Status
--- -------------------- ----- --------------------- -------- --------- -------
1 2 100BaseTX Supervisor WS-X2900 002477455 ok
2 12 100BaseTX Ethernet WS-X2902 002567322 ok
Mod MAC-Address(es) Hw Fw Sw
--- ---------------------------------------- ------ ------ ----------------
1 00-40-0b-b2-f4-00 thru 00-40-0b-b2-f7-ff 1.81 2.112 2.126
2 00-40-0b-d5-04-8c thru 00-40-0b-d5-04-97 1.4 1.2 2.126
catalyst-1:\
ht=ether:\
ha=0040b90b500:\
sm=255.255.255.0:\
ip=197.22.74.223
Simple Network Management Protocol (SNMP), an application-layer protocol, facilitates the exchange of management information bases (MIBs) between network devices. SNMP community strings authenticate access to the MIB and function as embedded "passwords." For an SNMP message to be processed, the community string must match one of following three community-string modes configured in the switch:
The switch sends a trap to the receiver (such as an SNMP manager or workstation) under the following conditions:
The set snmp trap command enters the IP address of the receiving station into the trap receiver table, which can hold up to ten addresses. When you enter addresses in the table, you must specify the community string that will appear in the trap message. You can control whether or not the switch issues a trap by using the set snmp trap enable or set snmp trap disable command.
To configure the switch to be managed using an SNMP network management workstation, perform the following steps:
Task | Command |
---|---|
Configure the SNMP community strings. See Figure 3-7 for an example. | set snmp community read-only | read-write | read-write-all community_string |
Assign a trap receiver address and community. If you enter incorrect information, use the clear snmp trap command to delete the entry. Then reenter the set snmp trap command again. | set snmp trap rcvr_address rcvr_community |
If desired, configure the switch so that it issues an authentication trap. | set snmp trap enable |
Check the SNMP settings using the show snmp command. See Figure 3-8 for an example. | show snmp |
Console> (enable) set snmp community read-only public
SNMP read-only community string set.
Console> (enable) set snmp community read-write private
SNMP read-write community string set.
Console> (enable) set snmp community read-write-all secret
SNMP read-write-all community string set.
To enable RMON on the Catalyst please use the following command:
Console> (enable) set snmp rmon enable
SNMP RMON support enabled.
Console> (enable) set snmp
Set snmp commands:
----------------------------------------------------------------------
set snmp community Set SNMP community string
set snmp help Show this message
set snmp rmon Set SNMP RMON
set snmp trap Set SNMP trap information
Console> (enable) set snmp trap
Usage:
set snmp trap <enable|disable> [all|module|chassis|bridge|repeater|auth|vtp]
set snmp trap <rcvr_address> <rcvr_community>
(rcvr_address is ipalias or IP address, rcvr_community is string)
Console> (enable) set snmp trap enable all
All SNMP traps enabled.
Console> (enable)
Console> show snmp
RMON: Enabled
Traps Enabled: Chassis
Port Traps Enabled: None
Community-Access Community-String
---------------- --------------------
read-only public
Trap-Rec-Address Trap-Rec-Community
---------------- --------------------
192.122.173.42 public
Console>
To configure the switch for remote monitoring (RMON) perform the following steps:
Task | Command |
---|---|
Activate SNMP remote monitoring support. See Figure 3-9 for an example. | set snmp rmon enable |
Check the SNMP settings using the show snmp command. Refer to Figure 3-10 for an example. | show snmp |
Console> (enable) set snmp rmon enable
SNMP RMON support enabled.
Console> show snmp
RMON: Enabled
Traps Enabled: Chassis
Port Traps Enabled: None
Community-Access Community-String
---------------- --------------------
read-only public
Trap-Rec-Address Trap-Rec-Community
---------------- --------------------
192.122.173.42 public
Console>
VLANs allow ports on the same or different switches to be grouped so that traffic is confined to members of that group only. This feature restricts broadcast, unicast, and multicast traffic (flooding) to only ports included in a certain VLAN. You can set up VLANs for an entire management domain from a single Catalyst 2900. A maximum of 250 VLANs can be active at any time.
Setting up VLANs for a management domain requires two tasks, as follows:
The set vtp and set vlan commands use Virtual Trunk Protocol (VTP) to set up VLANs across an entire management domain. The default configuration has all switched Ethernet ports and Ethernet repeater ports grouped as VLAN 1.
By default, the Catalyst 2900 is in the no-management domain state. They remain in this state until they are configured with a management domain or receive an advertisement for a domain. If a switch receives an advertisement, it inherits the management domain name and configuration revision number; it ignores advertisements with a different management domain or a smaller configuration revision number and checks all received advertisements with the same domain for consistency. While a Catalyst 2900 is in the no-management domain state, it is a VTP client: that is, it learns from received advertisements.
The set vtp command sets up the management domain. It establishes a management domain name or transparent, VLAN trunk protocol mode of operation (server or client), interval between VLAN advertisements, and password value. There is no default domain name (the value is set to null). The default advertisement interval is five minutes. The default VLAN trunk protocol mode of operation is set to server.
By default, the management domain is set to non-secure mode without a password. Adding a password sets the management domain to secure mode. A password might be configured on each Catalyst 2900 in the management domain when in secure mode.
Caution A management domain with a password does not function properly if the password is not assigned from each Catalyst 2900 in the domain. |
The set vlan command uses the following parameters to create a VLAN in the management domain:
The Catalyst 2900 uses the security association identifier (SAID) parameter of the set vlan command to identify each VLAN.The default SAID for VLAN 1 is 100001, for VLAN 2 is 100002, for VLAN 3 is 100003, and so on. The default maximum transmission unit (mtu) is 1,500 bytes. The default state is active on an 802.10 trunk.
When translating from one VLAN type to another, the Catalyst 2900 requires a different VLAN number for each of the media type.
To create a VLAN across a networking domain, perform the following steps in privileged mode:
Task | Command |
---|---|
Define the VLAN management domain, indicating the domain name, VLAN trunk protocol mode of operation, interval between VLAN advertisements, and password value. Figure 3-13 shows an example of the set vtp command. | set vtp [domain name] [mode mode] [interval interval] [passwd passwd] |
Verify that the VLAN management domain configuration is correct. Figure 3-12 shows a sample display of the show vtp domain command. | show vtp domain |
Define the VLAN, indicating the parameters described above: VLAN number, name, type, maximum transmission unit, SAID, state, ring number, and number to indicate whether source routing should be set to transparent or bridging. A maximum of 250 VLANs can be set at any time. Figure 3-13 shows an example of the set vlan command. | set vlan vlan_num [name name] [type type] [mtu mtu] [said said] [state state] [ring ring_number] [ [parent vlan_num] [stp stp_type] [translation vlan_num] |
Verify that the VLAN configuration is correct. | show vlan |
Console (enable) set vtp
Usage:
set vtp [domain <name>][mode <mode>][interval <interval>]
[passwd <passwd>]
(name: 1-32 characters, mode = (client, server, transparent),
interval = 120-600 sec, passwd : 0-64 characters)
Console> (enable) set vtp domain engineering mode client interval 160
VTP: domain engineering modified
Console> (enable)
Console> show vtp domain
Domain Name Domain Index VTP Version Local Mode
------------------------------ ------------ ----------- -----------
engineering 1 1 client
Last Updater Vlan-count Max-vlan-storage Config Revision Notifications
--------------- ---------- ---------------- --------------- -------------
172.20.25.130 5 256 0 disabled
Console> (enable) set vlan
Usage:
set vlan <vlan_num> <mod/ports...>
set vlan <vlan_num> [name <name>][type <type>][mtu <mtu>][said <said>]
[state <state>] [ring <ring_number>]
[parent <vlan_num>]
[stp <stp_type>] [translation <vlan_num>]
(An example of mod/ports is 1/1,2/1-12,3/1-2,4/1-12
type = (ethernet, token_ring,tr_net)
name = 1..32 characters, status = (active, suspend)
vlan_num = 1..1005)
Console> (enable) set vlan 3 name engineering type ethernet mtu 1500 said 3
VTP: vlan addition successful
Console> (enable)
Console> (enable) show vlan
VLAN Name Type Status Mod/Ports
---- -------------------------- ----- --------- ----------------
1 default enet active 2/1-24
3 vlan3 enet active
55 vlan55 enet active
88 vlan88 tring active
1002 token-ring-default tring active
1003 trnet-default trnet active
VLAN SAID MTU RingNo BridgeNo StpNo Parent Trans1 Trans2
---- ---------- ----- ------ -------- ----- ------ ------ ------
1 100001 1500 0 0 0 0 0 0
3 100003 1500 0 0 0 0 0 0
55 100085 1500 0 0 0 0 0 0
66 100102 4500 5000 0 0 5000 0 0
88 100088 1500 0 0 0 0 0 0
99 100099 1500 0 0 0 0 0 0
1002 101002 4500 0 0 0 0 1 1003
1003 101003 4500 0 0 0 0 1 1002
1004 101004 4500 0 1004 0 0 0 0
1005 101005 4500 0 1005 0 0 0 0
Use the set trunk command to configure trunks on ports and to configure the mode for the trunk: on, off, desirable, or auto. To establish a trunk, the port on each Catalyst 2900 must be configured as a trunk port. To establish trunks, perform the following steps in privileged mode:
Task | Command |
---|---|
Establish trunks on specific ports. Set the trunk to on to make it a trunk port, off to make it a non-trunk port, desirable to make it a trunk port if the port it is connected to allows trunking, or auto to make it a trunk port if the port it is connected to becomes set for trunking. Figure 3-15 shows an example of the set trunk command. Port 1 on module 1 is configured as a trunk. | set trunk mod_num/port_num [ on | off | desirable | auto ] [ vlans ] |
Verify that the trunk configuration is correct by using the show trunk command. | show trunk |
Console> (enable) set trunk 1/2 5
Port 1/2 allowed vlans modified to 1-5.
Console> (enable) set trunk 1/1 desirable
Port 1/1 mode set to desirable.
Port 1/1 has become a trunk.
Console> (enable) show trunk
Port Mode Status
------- --------- ------------
1/1 desirable trunking
1/2 auto not-trunking
3/1 auto not-trunking
3/2 auto not-trunking
3/3 auto not-trunking
3/4 auto not-trunking
3/5 auto not-trunking
3/6 auto not-trunking
3/7 auto not-trunking
3/8 auto not-trunking
3/9 auto not-trunking
3/10 auto not-trunking
3/11 auto not-trunking
3/12 auto not-trunking
Port Vlans allowed
------- ---------------------------------------------------------------
1/1 1-1000
1/2 1-5
3/1 1-1000
3/2 1-1000
3/3 1-1000
3/4 1-1000
3/5 1-1000
3/6 1-1000
3/7 1-1000
3/8 1-1000
3/9 1-1000
3/10 1-1000
3/11 1-1000
3/12 1-1000
Port Vlans active
------- ---------------------------------------------------------------
1/1 1,55
1/2 1
3/1 1
3/2 1
3/3 1
3/4 1
3/5 1
3/6 1
3/7 1
3/8 1
3/9 1
3/10 1
3/11 1
3/12 1
Console> (enable)
After you have configured the IP address(es), test for connectivity between the switch and a host. The host can reside anywhere in your network. To test for connectivity, perform the following steps:
Task | Command |
---|---|
Test the configuration using the ping command. The ping command sends an echo request to the host specified in the command line. | ping host |
If necessary, reset the configuration to its default values and reenter the configuration information. | clear config |
For example, to test connectivity from the switch to a workstation with an IP address of 192.34.56.5, enter the command ping 192.34.56.5. If the switch receives a response, the following message is displayed:
192.34.56.5 is alive
|