Confirming the Installation

Confirming the Installation

This section describes procedures used to confirm that the hardware and software installation and configuration procedures were successful. The following procedures are discussed:

Using the Module LEDs

This section describes the LEDs used to confirm and troubleshoot operation of the Catalyst 2900 modules. The LEDs on the supervisor engine module indicate the system power and processor status; LEDs on the switching modules indicate the status of the individual switching module and their interfaces.

Status LEDs

When the Catalyst 2900 is plugged in it runs a series of diagnostic tests. During this period, the status LED is orange. If the switch passes all the tests, the status LED is green. If any tests fail, the status LED turns red. The status LED will also be orange when it is explicitly disabled with the system software.

Supervisor Engine Module LEDs

The LEDs on the supervisor engine module reflect how the system's various components are operating and are described in Table 7-1. For a description of the power supply shutdown conditions and threshold status levels, refer to the section "Environmental Monitoring" in the chapter "What Is the Catalyst 2900?."

The supervisor engine module LEDs are shown in Figure 7-1.


Figure 7-1: Supervisor Engine Module LEDs




Table  7-1: Supervisor Engine Module LEDs
LED Description
Status The switch performs a series of self-tests and diagnostic tests.
If all the tests pass, the status LED is green.
If any test fails, the status LED is red.
During system boot or if the module is disabled, the LED is orange.
Fan Indicates whether or not the fans are operational.
If the fans are operational, the fan LED is green.
If the fans are not operational, the fan LED is red.
PS If the power supply is operational, the PS LED is green.
If the power supply detects an anomaly, the PS LED is red.
100 Mbps Green--Indicates that the port is operating at 100 Mbps.
Link Green--The port is operational.
Orange--The link has been disabled by software.
Orange flashing--The link is bad and has been disabled.
Off--No signal is detected.

Switch Load Meter

The switch load-meter LEDs provide a visual indication (as an approximate percentage) of the current traffic load over the backplane. (See Figure 7-2.)


Figure 7-2: Switch Load LED



10/100BaseTX LEDs

The LEDs provide status information for the module and individual 10/100 Mbps Fast Ethernet interface connections. The LEDs are shown in Figure 7-3 and described in Table 7-3.


Figure 7-3: 10/100 Mbps Fast Ethernet Switching Module LEDs




Table  7-2:
10/100 Mbps Fast Ethernet Module LED Descriptions
LED Description
Status The switch performs a series of self-tests and diagnostic tests.
If all the tests pass, the Status LED is green.
If any test fails, the Status LED is red (or orange for a minor fault).
During system boot or if the module is disabled, the LED is orange.
During self-test diagnostics, the LED will be orange.
If the module is disabled, the LED will be orange.
100-Mbps Green --Indicates that the port is operating at 100-mbps.
Link (bottom LED) Green --Indicates the port is operational (signal detected).
Orange--Link disabled by software.
Orange flashing--Port bad and disabled (hardware failure).
Off--No signal detected.

100BaseFX 12 Port LEDs

The LEDs on the faceplate of the Fast Ethernet switching module (100BaseFX 12 port), shown in Figure 7-4, are described in Table 7-3.


Figure 7-4: 100BaseFX LEDs




Table  7-3:
100BaseFX LED Descriptions
LED Description
Status The switch performs a series of self-tests and diagnostic tests.
If all the tests pass, the status LED is green.
If any test fails, the status LED is red (or orange for a minor fault or if manually disabled).
Link Green--the port is operational.
Orange--the link has been disabled by software.
Orange flashing--the link is bad and has been disabled.
Off--no signal is detected.

Using the ping Command

Enter the ping command to send Internet Control Message Protocol (ICMP) echo request packets to another node on the network to confirm the connection to that node.

ping -s host [packet_size] [packet_count]
Syntax Description
-s Causes ping to send one datagram per second, printing one line of output for every response received. The ping command does not return any output when no response is received.
host The IP address or IP alias of the host.
packet_size (Optional) The number of bytes in a packet, from 1 to 2,000 bytes, with a default of 56 bytes. The actual packet size is eight bytes larger because the switch adds header information.
packet_count (Optional) The number of packets to send.
Usage Guidelines

Enter Ctrl-C to stop pinging.

Following are sample results of the ping command:

Example

In the following example, a host with IP alias elvis is pinged a single time, then pinged once per second until Ctrl-C is entered to stop pinging:

Console> ping elvis elvis is alive Console> ping -s elvis ping elvis: 56 data bytes 64 bytes from elvis: icmp_seq=0. time=11 ms 64 bytes from elvis: icmp_seq=1. time=8 ms 64 bytes from elvis: icmp_seq=2. time=8 ms 64 bytes from elvis: icmp_seq=3. time=7 ms 64 bytes from elvis: icmp_seq=4. time=11 ms 64 bytes from elvis: icmp_seq=5. time=7 ms 64 bytes from elvis: icmp_seq=6. time=7 ms ^C ----elvis PING Statistics---- 7 packets transmitted, 7 packets received, 0% packet loss round-trip (ms) min/avg/max = 7/8/11 Console>

Using the show system Command

Enter the show system command to display the power supply, fan, temperature alarm, system, and modem status; the number of days, hours, minutes, and seconds since the last system restart; the baud rate; the MAC address range; and the system name, location, and contact.

Example

In the following example, the system status and other information is displayed:

Console> show system PS-Status Fan-Status Temp-Alarm Sys-Status Uptime d,h:m:s --------- ---------- ---------- ---------- -------------- ok ok off ok 27,17:05:50 Modem Baud MAC-Address-Range -------- ----- ------------------------------------- disabled 9600 00-06-3c-e4-0a-00 to 00-60-3e-e4-0d-ff System Name System Location System Contact ------------------------ ------------------------ ---------------------- WBU-Catalyst-2900 5 Closet 202 1/F Luis x5529 Console>

Using the show configuration Command

Enter the show config command to display the current system configuration:

Console> show config begin set password $1$FMFQ$HfZR5DUszVHIRhrz4h6V70 set enablepass $1$FMFQ$HfZR5DUszVHIRhrz4h6V70 set prompt Console> ! #system set system baud 9600 set system modem disable set system name Catalyst 2900 set system location Sunnyvale, CA set system contact Bob Lewis ! #snmp set snmp rmon enable set snmp community read-only public set snmp community read-write private set snmp community read-write-all secret set snmp trap 171.69.194.181 public set snmp trap disable ! #vlan/trunk clear trunk all ! set vlan 1 1/1-2,2/1-24 ! #trunks ! #MAC filters clear filter all ! #cam set cam agingtime 0 ! #spantree #vlan 1 set spantree enable 1 set spantree fwddelay 20 1 set spantree hello 2 1 set spantree maxage 20 1 set spantree priority 45 1 set spantree portpri 1/1 32 set spantree portcost 1/1 100 set spantree portpri 1/2 32 set spantree portcost 1/2 100 set spantree portpri 2/1 32 set spantree portcost 2/1 100 . . . set spantree portpri 2/12 32 set spantree portcost 2/12 100 ! #vlan trunk/monitor ! #ip set interface sc0 192.122.174.220 255.255.255.0 192.122.174.255 set redirect enable set route 0.0.0.0 192.122.174.102 1 set arp agingtime 1200 ! #cdp set cdp 1/1 enable 60 set cdp 1/2 enable 60 set cdp 2/1 enable 60 set cdp 2/2 enable 60 set cdp 2/3 enable 60 . . . set cdp 2/12 enable 60 ! #ipalias set ipalias default 0.0.0.0 set ipalias cres 192.122.173.42 set ipalias calypso 171.69.194.181 ! #alias ! #port monitoring set monitor 1 1/1 both set monitor disable ! #module 1 set port enable 1/1 set port name 1/1 set port duplex 1/1 auto set port speed 1/1 10 set port level 1/1 auto set port enable 1/2 set port name 1/2 set port duplex 1/2 10 set port speed 1/2 100 set port level 1/2 auto ! #module 2 set module enable 2 ! set port enable 2/1 set port name 2/1 auto set port duplex 2/1 100 set port level 2/1 100 set port enable 2/2 set port name 2/2 set port duplex 2/2 10 set port level 2/2 auto . . set port enable 2/12 set port name 2/12 set port duplex 2/12 10 set port level 2/12 10 ! end

Using the show port Command

Enter the show port command to display the current system configuration: Console> show port Port Name Status Vlan Level Duplex Speed Type ---- ----------- -------- -------- ------ ------ ------ ----------- 1/1 ready 1 normal half 100 100 BASE-TX 1/2 ready 1 normal half 100 100 BASE-TX 2/1 network ready 1 normal half 10 10 BASE-T 2/2 connect 1 normal half 10 10 BASE-T 2/3 connect 1 normal half 10 10 BASE-T 2/4 connect 1 normal half 10 10 BASE-T 2/5 connect 1 normal half 10 10 BASE-T 2/6 connect 1 normal half 10 10 BASE-T 2/7 connect 1 normal half 10 10 BASE-T 2/8 connect 1 normal half 10 10 BASE-T 2/9 connect 1 normal half 10 10 BASE-T 2/10 connect 1 normal half 10 10 BASE-T 2/11 connect 1 normal half 10 10 BASE-T 2/12 connect 1 normal half 10 10 BASE-T Port Align-Err FCS-Err Xmit-Err Rcv-Err ---- ---------- ---------- ---------- ---------- 1/1 0 0 0 0 1/2 0 0 0 0 2/1 0 0 0 0 2/2 0 0 0 0 2/3 0 0 0 0 2/4 0 0 0 0 2/5 0 0 0 0 2/6 0 0 0 0 2/7 0 0 0 0 2/8 0 0 0 0 2/9 0 0 0 0 2/10 0 0 0 0 2/11 0 0 0 0 2/12 0 0 0 0 Port Single-Col Multi-Coll Late-Coll Excess-Col Carri-Sens Giants ---- ---------- ---------- ---------- ---------- ---------- ---------- 1/1 0 0 0 0 0 0 1/2 0 0 0 0 0 0 2/1 0 0 0 0 0 0 2/2 0 0 0 0 0 0 2/3 0 0 0 0 0 0 2/4 0 0 0 0 0 0 2/5 0 0 0 0 0 0 2/6 0 0 0 0 0 0 2/7 0 0 0 0 0 0 2/8 0 0 0 0 0 0 2/9 0 0 0 0 0 0 2/10 0 0 0 0 0 0 2/11 0 0 0 0 0 0 2/12 0 0 0 0 0 0 Last-Time-Cleared -------------------------- Fri Apr 28 1995, 16:34:25 Console>

Console> (enable) show port
Port Name Status Vlan Level Duplex Speed Type
---- -------------------- ---------- ---------- ------ ------ ----- --------------
1/1 Management Port notconnect 1 normal half 100 100 BASE-TX
1/2 InterSwitchLink connected trunk normal half 100 100 BASE-TX
2/1 Dennis connected 10 normal a-half a-10 10/100 BASE-TX
2/2 Luis notconnect 10 normal auto auto 10/100 BASE-TX
2/3 Iris notconnect 10 normal auto auto 10/100 BASE-TX
2/4 Nancy connected 10 normal a-half a-10 10/100 BASE-TX
2/5 Arthur notconnect 20 normal auto auto 10/100 BASE-TX
2/6 Ron notconnect 20 normal auto auto 10/100 BASE-TX
2/7 Connie disabled 20 normal auto auto 10/100 BASE-TX
2/8 Bill notconnect 20 normal auto auto 10/100 BASE-TX
2/9 notconnect 20 normal auto auto 10/100 BASE-TX
2/10 notconnect 20 normal auto auto 10/100 BASE-TX
2/11 notconnect 20 normal auto auto 10/100 BASE-TX
2/12 notconnect 20 normal full auto 10/100 BASE-TX

Port Align-Err FCS-Err Xmit-Err Rcv-Err
---- ---------- ---------- ---------- ----------
1/1 0 0 0 0
1/2 1 0 0 0
2/1 0 0 0 0
2/2 0 0 0 0
2/3 0 0 0 0
2/4 30 0 0 0
2/5 0 0 0 0
2/6 0 0 0 0
2/7 0 0 0 0
2/8 0 0 0 0
2/9 0 0 0 0
2/10 0 0 0 0
2/11 0 0 0 0
2/12 0 0 0 0

Port Single-Col Multi-Coll Late-Coll Excess-Col Carri-Sens Giants
---- ---------- ---------- ---------- ---------- ---------- ----------
1/1 0 0 0 0 0 0
1/2 680 418 0 1 0 -
2/1 756 99 0 0 0 0
2/2 0 0 0 0 0 0
2/3 0 0 0 0 0 0
2/4 409 403 0 11 0 1256
2/5 0 0 0 0 0 0
2/6 0 0 0 0 0 0
2/7 0 0 0 0 0 0
2/8 0 0 0 0 0 0
2/9 0 0 0 0 0 0
2/10 0 0 0 0 0 0
2/11 0 0 0 0 0 0
2/12 0 0 0 0 0 0

Last-Time-Cleared
--------------------------
Wed Dec 27 1995, 16:09:47
Console> (enable)