cc/td/doc/product/lan/c3550
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Release Notes for the
Catalyst 3550 Multilayer Switch
Cisco IOS Release 12.1(8)EA1c

Release Notes for the
Catalyst 3550 Multilayer Switch
Cisco IOS Release 12.1(8)EA1c

February 15, 2002

Cisco IOS Release 12.1(8)EA1c runs on all Catalyst 3550 multilayer switches.

These release notes include important information about this IOS release and any limitations, restrictions, and caveats that apply to it. Verify that these are the correct release notes for your switch:

For the complete list of Catalyst 3550 switch documentation, see the "Related Documentation" section.

This IOS release is part of a special release of Cisco IOS software that is not released on the same 8-week maintenance cycle that is used for other platforms. As maintenance releases and future IOS releases become available, they will be posted to Cisco.com (previously Cisco Connection Online [CCO]) in the Cisco IOS software area.

Contents

This document has these sections:

System Requirements

This section describes these system requirements for this IOS release:

Hardware Supported

Table 1 lists the hardware supported by this IOS release.


Table 1: Supported Hardware
Switch Description

Catalyst 3550-12T

10 Gigabit Ethernet 10/100/1000BASE-T ports and 2 Gigabit Interface Converter (GBIC)-based Gigabit Ethernet slots

Catalyst 3550-12G

10 GBIC-based Gigabit Ethernet slots and 2 10/100/1000BASE-T ports

Catalyst 3550-24

24 autosensing 10/100 Ethernet ports and 2 GBIC-based Gigabit Ethernet slots

Catalyst 3550-48

48 autosensing 10/100 Ethernet ports and 2 GBIC-based Gigabit Ethernet slots

GBIC modules

  • 1000BASE-SX GBIC

  • 1000BASE-LX/LH GBIC

  • 1000BASE-ZX GBIC

  • 1000BASE-T GBIC

  • GigaStack GBIC

Redundant power system

Cisco RPS 300 Redundant Power System

Software Compatibility

This section describes these software compatibility requirements for this IOS release:

Recommended Platform Configuration for Web-Based Management

Table 2 lists the recommended platforms for Web-based management.


Table 2: Recommended Platform Configuration for Web-Based Management
OS Processor Speed DRAM Number of Colors Resolution Font Size

Windows NT 4.01

Pentium 300 MHz

128 MB

65,536

1024 x 768

Small

Solaris 2.5.1

SPARC 333 MHz

128 MB

Most colors for applications

Small (3)

1Service Pack 3 or higher is required.

The minimum PC requirement is a Pentium processor running at 233 MHz with 64 MB of DRAM. The minimum UNIX workstation requirement is a Sun Ultra 1 running at 143 MHz with 64 MB of DRAM.

For information about supported operating systems, see the next section.

Operating System and Browser Support

You can access the web-based interfaces by using the operating systems and browsers listed in Table 3. The switch checks the browser version when starting a session to ensure that the browser is supported. If the browser is not supported, the switch displays an error message, and the session does not start.


Table 3: Supported Operating Systems and Browsers
Operating System Minimum Service Pack or Patch Netscape Communicator1 Microsoft Internet Explorer2

Windows 95

Service Pack 1

4.61, 4.7x

4.01a, 5.0, 5.5

Windows 98

Second Edition

4.61, 4.7x

4.01a, 5.0, 5.5

Windows NT 4.0

Service Pack 3 or later

4.61, 4.7x

4.01a, 5.0, 5.5

Windows 2000

None

4.61, 4.7x

4.01a, 5.0, 5.5

Solaris 2.5.1 or later

Sun-recommended patch cluster for the OS and Motif library patch 103461-24

4.61, 4.7x

Not supported

1Netscape Communicator versions 4.60 and 6.0 are not supported.
2Service Pack 1 or higher is required for Internet Explorer 5.5.


Note   If your browser is Internet Explorer and you receive an error message stating that the page might not display correctly because your security settings prohibit running activeX controls, this might mean that your security settings are set too high. To lower security settings, go to Tools > Internet Options, and select the Security tab. Select the indicated Zone, and move the Security Level for this Zone slider from High to Medium (the default).


Note   In Cluster Management displays, Internet Explorer versions 4.01 and 5.0 might not display edge devices that are not connected to the command switch. Other functionality is similar to that of Netscape Communicator.

Installing the Required Plug-In

A Java plug-in is required for the browser to access the Java-based Cluster Management Suite (CMS). Download and install the plug-in before you start CMS. Each platform, Windows and Solaris, supports three plug-in versions. For information on the supported plug-ins, see the "Windows 2000, Windows 95, Windows 98, and Windows NT 4.0 Platforms" section and the "Solaris Platforms" section.

You can download the recommended plug-ins from this URL: http://www.cisco.com/pcgi-bin/tablebuild.pl/java


Note   Uninstall older versions of the Java plug-ins before installing the Java plug-in.

If the Java applet does not initialize after you have installed the plug-in, open the Java Plug-in Control Panel (Start > Programs > Java Plug-in Control Panel), and verify these settings:

In the Proxies tab, verify that Use browser settings is checked and that no proxies are enabled.


Note   If you are running an Internet virus checker on Windows 2000 and the plug-in takes a long time to load, you can speed up CMS operation by disabling the virus checker filter option or download option or both.

On McAfee VirusScan, from the Start menu, to disable the VirusScan Internet Filter option, the Download Scan option, or both, select Start > Programs > Network Associates > Virus Scan Console > Configure.

or

From the taskbar, right-click the Virus Shield icon and in the Quick Enable menu, disable the options by deselecting Internet Filter or Download Scan.

Windows 2000, Windows 95, Windows 98, and Windows NT 4.0 Platforms

These Java plug-ins are supported on the Windows platform:

You can download these plug-ins from this URL:

http://www.cisco.com/pcgi-bin/tablebuild.pl/java


Note   If you start CMS without having installed the required Java plug-in, the browser automatically detects this. If you are using a supported Internet Explorer browser, it automatically downloads and installs the Java plug-in 1.3.0 (default). If you are using a supported Netscape browser, the browser displays a Cisco.com page that contains the Java plug-in and installation instructions. If you are using Windows 2000, Netscape Communicator might not detect the missing Java plug-in.

Solaris Platforms

These Java plug-ins are supported on the Solaris platform:


Caution   To avoid performance and compatibility issues, do not use Java plug-ins later than Java plug-in 1.3.1.

You can download these plug-ins and instructions from this URL:

http://www.cisco.com/pcgi-bin/tablebuild.pl/java

To install the Java plug-in, follow the instructions in the README_FIRST.txt file.

Creating Clusters with Different Releases of IOS Software

When a cluster consists of a mixture of other Catalyst switches, we strongly recommend using only the Catalyst 3550 switches as the command and standby command switches. When the command switch is a Catalyst 3550 switch, all standby command switches must also be Catalyst 3550 switches. The Catalyst 3550 switch that has the latest software should be the command switch. If the command switch is a Catalyst 3550 Gigabit Ethernet switch and the standby command switch is a Catalyst 3550 Fast Ethernet switch, command switch port speeds are reduced if the standby command switch takes over.

If your cluster has Catalyst 2950, Catalyst 2900 XL, and Catalyst 3500 XL switches, the Catalyst 2950 switch (with the latest software release) should be the command switch. The Catalyst 2950 switch that has the latest software should be the command switch.

If your switch cluster has Catalyst 1900, Catalyst 2820, Catalyst 2900 XL, and Catalyst 3500 XL switches, either the Catalyst 2900 XL or Catalyst 3500 XL (whichever has the latest software release) should be the command switch.

Table 4 lists the cluster capabilities and software versions for the switches.


Table 4: Switch Software and Cluster Capability
Switch IOS Release Cluster Capability

Catalyst 3550

Release 12.1(4)EA1 or later

Member or command switch

Catalyst 3500 XL

Release 12.0(5.1)XU or later

Member or command switch

Catalyst 2950

Release 12.0(5.2)WC(1) or later

Member or command switch

Catalyst 2900 XL (8-MB switches)

Release 12.0(5.1)XU or later

Member or command switch

Catalyst 2900 XL (4-MB switches)

Release 11.2(8.5)SA6 (recommended)

Member switch only

Catalyst 1900 and 2820

Release 9.00(-A or -EN) or later

Member switch only

Some versions of the Catalyst 2900 XL software do not support clustering and if you have a cluster with switches that are running different versions of IOS software, software features added on the latest release might not be reflected on switches running the older versions. For example, if you start Visual Switch Manager (VSM) on a Catalyst 2900 XL switch running Release 11.2(8)SA6, the windows and functionality can be different from a switch running Release 12.0(5)WC(1) or later.


Note   The CMS is not forward-compatible, which means that if a member switch is running a software version that is newer than the release running on the command switch, the new features are not available on the member switch. If your member switch is a new device that is running a software release that is later than software release on the command switch or a new switch model released after the software release running on the command switch, the member switch is displayed as an unknown device in the Front Panel view. You cannot configure any parameters or generate a report through CMS for that member; instead, you must launch the Device Manager application to perform configuration and obtain reports for that member.

Downloading Software

This section describes these procedures for downloading software:

Determining the Software Version and Feature Set

The IOS image is stored as a .bin file in a directory that is named with the IOS release. A subdirectory contains the HTML files needed for web management. The image is stored on the system board Flash device (flash:).

You can use the show version privileged EXEC command to see the software version that is running on your switch. In the display, check the line that begins with System image file is. It shows the directory name in Flash memory where the image is stored. A couple of lines below the image name, you see Running Layer 2/3 Switching Image if you are running the enhanced multilayer software image, or Running Layer 2 Switching Image Only if you are running the standard multilayer software image.


Note   Although the show version output always shows the software image running on the switch (Layer 2 or Layer 2/3), the model name shown at the end of this display is the factory configuration (SMI or EMI) and does not change if you upgrade the software image.

You can also use the dir filesystem: privileged EXEC command to see the directory names of other software images that you might have stored in Flash memory.

Which Files to Use

The upgrade procedures in these release notes describe how to perform the upgrade by using a combined .tar file. This file contains both the IOS image file and the HTML files (needed for the CMS). You must use the combined .tar file to upgrade the switch through the CMS.

The .tar file is an archive file from which you can extract files by using the tar command. You also use the .tar file to upgrade the system by using the archive download-sw privileged EXEC command.

Table 5 lists the software file names for this IOS release.


Table 5: Cisco IOS Software Files for Catalyst 3550 Switches
Filename Description

c3550-i9q3l2-mz.121-0.210.EA1c.tar

IOS image file and HTML files
This image, the standard multilayer software image (SMI), has Layer 2+ features only.

c3550-i5q3l2-mz.121-0.210.EA1c.tar

IOS image file and HTML files
This image, the enhanced multilayer software image (EMI), has both Layer 2 and Layer 3 features.


Note   All Catalyst 3550 Gigabit Ethernet switches ship with the enhanced multilayer software image (EMI) installed. This image is an orderable upgrade for Catalyst 3550 Fast Ethernet switches with the standard multilayer software image (SMI) pre-installed.

Upgrading a Switch by Using CMS

You can upgrade switch software by using CMS. From the menu bar, select Administration > Software Upgrade. For detailed instructions, click Help.

Upgrading a Switch by Using the CLI

This procedure is for copying the combined .tar file to the Catalyst 3550 switch. You copy the file to the switch from a TFTP server and extract the files. You can download an image file and replace or keep the current image.

To download software, and if necessary, the TFTP server application, follow these steps:


Step 1   Use Table 5 to identify the file that you want to download.

Step 2   Download the software image file.

If you have a SmartNet support contract, go to this URL and log in to download the appropriate files:

http://www.cisco.com/kobayashi/sw-center/sw-lan.shtml

If you do not have a SmartNet contract, go to this URL and follow the instructions to register on Cisco.com and download the appropriate files:

http://www.cisco.com/public/sw-center/sw-lan.shtml

Step 3   Download the Cisco TFTP server from the URL link from Step 2, if necessary. The information on this page describes how to download and configure the TFTP server.

Step 4   Copy the image to the appropriate TFTP directory on the workstation, and make sure the TFTP server is properly configured.

For more information, refer to Appendix B in the Catalyst 3550 Multilayer Switch Software Configuration Guide.

Step 5   Log in to the switch through the console port or a Telnet session.

Step 6   Check your VLAN 1 configuration by using the show interfaces vlan 1 privileged EXEC command, and verify that VLAN 1 is part of the same network as the TFTP server. (Check the Internet address is line near the top of the display.)

Step 7   Download the image file from the TFTP server to the switch. If you are installing the same version of software that is currently on the switch, overwrite the current image by using this privileged EXEC command:

archive download-sw /overwrite /reload tftp:[[//location]/directory]/image-name.tar

The /overwrite option overwrites the software image in Flash memory with the downloaded one.

The /reload option reloads the system after downloading the image unless the configuration has been changed and not been saved.

For //location, specify the IP address of the TFTP server.

For /directory/image-name.tar, specify the directory (optional) and the image to download. Directory and image names are case sensitive.

This example shows how to download an image from a TFTP server at 172.20.129.10 and to overwrite the image on the switch:

Switch# archive download-sw /overwrite tftp://172.20.129.10/c3550-i5q3l2-mz.121-8.EA1c.tar
Note   You can also download the image file from the TFTP server to the switch and keep the current image by replacing the /overwrite option with the /leave-old-sw option.


Recovering from Software Failure

In the software fails, you can reload the software. For detailed recovery procedures, refer to the "Troubleshooting" chapter in the Catalyst 3550 Multilayer Switch Software Configuration Guide.

Installation Notes

You can assign IP information to your switch by using the setup program, the Dynamic Host Configuration Protocol (DHCP)-based autoconfiguration (refer to the Catalyst 3550 Multilayer Switch Software Configuration Guide), or by manually assigning an IP address (refer to the Catalyst 3550 Multilayer Switch Software Configuration Guide).

This section describes these installation procedures:

Setting Up the Catalyst 3550 Initial Configuration

The first time that you access the switch, it runs a setup program that prompts you for an IP address and other configuration information necessary for the switch to communicate with the local routers and the Internet. This information is also required if you plan to use the CMS to configure and manage the switch.


Note   If the switch will be a cluster member managed through the IP address of the command switch, it is not necessary to assign IP information or a password. If you are configuring the switch as a standalone switch or as a command switch, you must assign IP information.

Follow these steps to create an initial configuration for the switch:


Step 1   Enter Yes at the first two prompts.

Would you like to enter the initial configuration dialog? [yes/no]: yes At any point you may enter a question mark '?' for help. Use ctrl-c to abort configuration dialog at any prompt. Default settings are in square brackets '[]'. Basic management setup configures only enough connectivity for management of the system, extended setup will ask you to configure each interface on the system. Would you like to enter basic management setup? [yes/no]: yes

Step 2   Enter a host name for the switch, and press Return.

On a command switch, the host name is limited to 28 characters; on a member switch to 31 characters. Do not use -n, where n is a number, as the last character in a host name for any switch.

Enter host name [Switch]: host_name

Step 3   Enter a secret password, and press Return.

The password can be from 1 to 25 alphanumeric characters, can start with a number, is case sensitive, allows spaces, but ignores leading spaces.

Enter enable secret: secret_password

Step 4   Enter an enable password, and press Return.

Enter enable password: enable_password

Step 5   Enter a virtual terminal (Telnet) password, and press Return.

The password can be from 1 to 25 alphanumeric characters, is case sensitive, allows spaces, but ignores leading spaces.

Enter virtual terminal password: terminal-password

Step 6   (Optional) Configure Simple Network Management Protocol (SNMP) by responding to the prompts.

Step 7   Enter the interface name (physical interface or VLAN name) of the interface that connects to the management network, and press Return. For this release, always use vlan 1 as that interface.

Enter interface name used to connect to the management network from the above interface summary: vlan 1

Step 8   Configure the interface by entering the switch IP address and subnet mask and pressing Return:

Configuring interface vlan 1: Configure IP on this interface? [yes]: yes IP address for this interface: 10.4.120.106 Subnet mask for this interface [255.0.0.0]: 255.255.255.0

Step 9   Enter Y to configure the switch as the cluster command switch. Enter N to configure it as a member switch or as a standalone switch.

If you enter N, the switch appears as a candidate switch in the CMS. In this case, the message in Step 10 is not displayed.

Would you like to enable as a cluster command switch? [yes/no]: yes

Step 10   Assign a name to the cluster, and press Return.

Enter cluster name: cluster_name

The cluster name can be 1 to 31 alphanumeric characters, dashes, or underscores.

The initial configuration appears:

The following configuration command script was created: hostname host-name enable secret 5 $1$LiBw$0Xc1wyT.PXPkuhFwqyhVi0 enable password enable-password line vty 0 15 password terminal-password snmp-server community public ! no ip routing ! interface vlan 1 no shutdown ip address 10.4.120.106 255.255.255.0 interface GigabitEthernet0/1 no ip address ! interface GigabitEthernet0/2 no ip address ! ...<output abbreviated> ! interface GigabitEthernet0/12 no ip address cluster enable cluster-name ! end

Step 11   These choices are displayed:

[0] Go to the IOS command prompt without saving this config. [1] Return back to the setup without saving this config. [2] Save this configuration to nvram and exit. Enter your selection [2]:2

Make your selection, and press Return.


After you complete the setup program, the switch can run the created default configuration. If you want to change this configuration or want to perform other management tasks, use one of these tools:

Configuring Browsers and Accessing CMS

For the browser to use CMS, a Java plug-in is required, as described in the "Installing the Required Plug-In" section. After you have assigned an IP address to the switch and installed the plug-in, you can access the switch from your browser and use the CMS to configure other switches. To use the web-based tools, see the "Software Compatibility" section to set up the appropriate browser options.

This section describes these installation procedures:

Configuring Netscape Communicator (All Versions)

Follow these steps to configure Netscape Communicator:


Step 1   Start Netscape Communicator.

Step 2   From the menu bar, select Edit > Preferences.

Step 3   In the Preferences window, click Advanced.

Step 4   Check the Enable Java, Enable JavaScript, and Enable Style Sheets check boxes.

Step 5   From the menu bar, select Edit > Preferences.

Step 6   In the Preferences window, click Advanced Cache, and select Every time.

Step 7   Click OK to return to the browser Home page.


Configuring Microsoft Internet Explorer (4.01)

Follow these steps to configure Microsoft Internet Explorer 4.01:


Step 1   Start Internet Explorer.

Step 2   From the menu bar, select View > Internet Options.

Step 3   In the Internet Options window, click the Advanced tab.

Step 4   In the Internet Options window, click the General tab.


Configuring Microsoft Internet Explorer (5.0)


Note   During the installation of this browser, make sure to check the Install Minimal or Customize Your Browser check box. In the Component Options window in the Internet Explorer 5 section, make sure to check the Microsoft Virtual Machine check box to display applets written in Java.

Follow these steps to configure Microsoft Internet Explorer 5.0:


Step 1   Start Internet Explorer.

Step 2   From the menu bar, select Tools > Internet Options.

Step 3   In the Internet Options window, click the Advanced tab.

Step 4   In the Internet Options window, click the General tab.


If you are using Microsoft Internet Explorer 5.0 to make configuration changes to the switch, note that this browser does not automatically reflect the latest configuration changes. Make sure that you click Refresh for every configuration change.

Displaying the CMS Access Page

After the browser is configured, display the CMS access page:


Step 1   Enter the switch IP address in the browser Location field (Netscape Communicator) or Address field (Internet Explorer), and press Return.

Step 2   Enter your username and password when prompted. The password provides level 15 access. The Cisco Systems Access page appears. For more information on setting passwords and privilege levels, refer to the Catalyst 3550 Multilayer Switch Software Configuration Guide.

Step 3   Click Web Console to launch the CMS applet.

If you access CMS from a standalone or a cluster-member switch, Device Manager appears.


New Features

This section describes the new supported hardware and the new software features for the Catalyst 3550 switches that are provided in IOS Release 12.1(8)EA1.

New Hardware Features

For a list of supported hardware, see the "Hardware Supported" section.

New Software Features

Cisco IOS Release 12.1(8)EA1 contains these new features or enhancements:

Limitations and Restrictions

You should review this section before you begin working with the switches. These are known limitations that will not be fixed, and there is not always a workaround. Some features might not work as documented, and some features could be affected by recent changes to the switch hardware or software.


Caution   Switches in a VTP domain always use the VLAN configuration of the switch with the highest VTP configuration revision number. If you add a switch that has a revision number higher than the revision number in the VTP domain, it can erase all VLAN information from the VTP server and VTP domain.

After updating a multicast boundary, the workaround is to use the clear ip mroute privileged EXEC command to delete any existing multicast routes that violate the updated boundary. (CSCdr79083)

When you remove an EtherChannel group, enter the no shutdown interface configuration command on the interfaces that belonged to the port group to bring them back on line. (CSCdt10825)

The workaround is to not configure the switch to operate with more than the maximum number of supported multicast routes. You can use the show sdm prefer and show sdm prefer routing privileged EXEC commands to view approximate maximum configuration guidelines for the current SDM template and the routing template. ((CSCdt63354))

The workaround is to disable the Port Aggregation Protocol (PAgP) on both devices by using the channel-group channel-group-number mode on interface configuration command. PAgP negotiation between these two devices is not reliable. (CSCdt78727)

When the security hardware ACL matches a packet on input, the match uses the original DSCP value. For output security ACLs, the security ACL hardware should match against the final, possibly changed, DSCP value as set by the QoS hardware. Under some circumstances, a match to a security ACL in hardware prevents the QoS hardware from rewriting the DSCP and causes the CPU to use the original DSCP.

If a security ACL is applied in software (because the ACL did not fit into hardware, and packets were sent to the CPU for examination), the match probably uses the new DSCP value as determined by the QoS hardware, regardless of whether the ACL is applied at the input or at the output. When packets are logged by the ACL, this problem can also affect whether or not a match is logged by the CPU even if the ACL fits into hardware and the permit or deny filtering was completed in hardware.

To avoid these issues, whenever the switch rewrites the DSCP of any packet to a value different from the original DSCP, security ACLs should not test against DSCP values in any of their access control elements (ACEs), regardless of whether the ACL is being applied to an IP access group or to a VLAN map. This restriction does not apply to ACLs used in QoS class maps.

If the switch is not configured to rewrite the DSCP value of any packet, it is safe to match against DSCP in ACLs used for IP access groups or for VLAN maps because the DSCP does not change as the packet is processed by the switch.

The DSCP field of an IP packet encompasses the two fields that were originally designated precedence and TOS (type of service). Statements relating to DSCP apply equally to either IP precedence or IP TOS. (CSCdt94355)

This problem has been fixed in hardware on Catalyst 3550-24 switches with motherboard assembly number 73-5700-08 or later. To determine the board level on your switch, enter the show version privileged EXEC. Motherboard information appears toward the end of the output display. (CSCdv68158)

If you use the ip igmp max-groups interface configuration command to set the maximum number of IGMP groups for an interface to 0, the port still receives group reports from reserved multicast groups (224.0.0.x) and their Layer 2 aliases (y.0.0.x). (CSCdv79832)

Important Notes

This section describes important information related to this IOS release.

Resize the browser window again when CMS is not busy.

The workaround is to remove all the jar_cache*.tmp files from the temporary directory. The path to the directory is different for different operating systems:

Solaris: /var/tmp
Windows NT and Windows 2000: \TEMP
Windows 95 and 98: \Windows\Temp

Open Caveats

This section describes these open caveats with possible unexpected activity in this IOS release:

Open IOS Caveats

This section describes the severity 3 IOS configuration caveats:

If you configure the DHCP server to allocate addresses from a pool to the switch, two devices on the network might have the same IP address. Pooled addresses are temporarily allocated to a device and are returned to the pool when not in use. If you save the configuration file after the switch receives such an address, the pooled address is saved, and the switch does not attempt to access the DHCP server after a reboot to receive a new IP address. As a result, two devices might have the same IP address.

The workaround is to make sure that you configure the DHCP server with reserved leases that are bound to each switch by the switch hardware address.

If you try to configure an ACL that uses the log keyword, an error is displayed, and a match none statement is added to the show class-map class-map-name display. Not only does the match none statement make the ACL useless, but any previously entered match commands for the same class map are not retained.

The workaround is to re-enter the old ACL without the log keyword.

When the switch is operating with equal-cost routes and it is required to learn more unicast routes than it can support, the CPU might run out of memory, and the switch might fail.

The workaround is to remain within the documented recommended and supported limits.

If Catalyst 3550 GBIC ports containing GigaStack GBICs are configured as routed ports with EtherChannel group assignments, they might not correctly join the channel group.

GigaStack GBICs are not supported as EtherChannel group members on the Catalyst 3550 switch. The workaround is to not configure channel-group settings on interfaces containing GigaStack GBICs.

You cannot set the vmVlanType object in CISCO-VLAN-MEMBERSHIP-MIB, which means that you cannot convert a port from static to dynamic access using SNMP.

The workaround is to use the switchport access vlan dynamic interface configuration command to to change an access port from static to dynamic.

The switch does not generate the vmVmpsChange trap in CISCO-VLAN-MEMBERSHIP-MIB, so there is no way to monitor VMPS change event by using SNMP.

There is no workaround.

If a routed interface is configured with a multicast boundary by using the ip multicast boundary interface configuration command, and there are ACLs configured, if the ACLs are modified or the multicast boundary is removed, this might not affect the existing multicast routes.

The workaround is to delete the multicast routing table by using the clear ip mroute * privileged EXEC command.

If you configure a trunk port for Dynamic Trunking Protocol (DTP) nonegotiate mode and change the encapsulation type from ISL to 802.1Q by using the switchport trunk encapsulation interface configuration command, the port becomes an access port and is no longer trunking.

There is no workaround.

The switch might fail while deleting 7000 multicast routes with the maximum number of SVIs supported by the SDM access template.

There is no workaround.

If you use the setup program for initial configuration and set an IP address for a specific port (making it a router port and not a switch port), the setup program does not write the no switchport interface configuration command to the configuration file, making the port unusable without manual reconfiguration.

The workaround is to not use the setup program for configuring routed ports. Always enter no when prompted with the Configure IP on this interface? message.

After you change connections between GigaStack ports, the link might not be established, and LEDs on the GigaStack GBIC might continue to blink for more than 2 minutes. (It is normal for the LEDs to blink for a short time.)

The workaround is to disconnect and reconnect one of the links connected to the GigaStack GBIC with the continuous blinking LEDs.

If a port is put into self-looped state, Spanning Tree Protocol (STP) remains in the blocking state after the self-looped condition is removed.

The workaround is to enter the shutdown interface configuration command followed by the no shutdown interface configuration command on the port in the blocking state.

If a stack contains both Catalyst 3550 switches and Catalyst 3500 XL or Catalyst 2900 XL switches, cross-stack UplinkFast does not function if the management VLAN on the Catalyst 3500 XL or Catalyst 2900 XL switches is changed to other than VLAN 1 (the default).

The workaround is to make sure that the management VLAN of all Catalyst 3500 XL or 2900 XL switches in the stack is set to VLAN 1.

After you have changed the system maximum transmission unit (MTU) size by using the system mtu global configuration command, the new MTU value is applied to all interfaces on the switch. However, the show interfaces privileged EXEC command still displays the default MTU size (1500 bytes), which could mislead you about the maximum MTU size on the interface.

The workaround is to use the show system mtu privileged EXEC command to verify the setting of the system MTU.

When you configure a switch port to block flooded traffic by using the switchport block interface configuration command, and then configure the port as a SPAN destination port by using the monitor session session_number destination interface interface_id global configuration command, the block settings might remain enabled during the SPAN session, causing traffic sent to unknown addresses to be blocked instead of forwarded to the destination port.

The workaround is to disable any switchport block settings on the port by using the no switchport block interface command before using the monitor session command to configure the port as a destination port.

When you use the sdm prefer global configuration command to select a template to be used for Switch Database Management (sdm) resource allocation, the new template takes effect after the next switch reload even if you did not save the configuration file.

The workaround, if you do not want the new template to take effect, is to use the no sdm prefer global configuration command to return to the previously configured template.

Using the standby mac-address interface configuration command has no effect on the MAC address used by HSRP on the Catalyst 3550 switch.

There is no workaround. The switch uses only the standard MAC address prefix for all HSRP standby groups.

If you use the system mtu global configuration command to increase the system MTU to more than 1500 bytes and if a VLAN map is configured that cannot be accommodated by hardware resources, frames larger than 1524 bytes might be sent to the CPU. These frames will be truncated at the CPU, and a truncated frame will be forwarded.

There is no workaround.

The copy running-config startup-config privileged EXEC command fails if the running configuration of the Catalyst 3550 exceeds 32 K. To save the configuration, you must increase the size of the simulated NVRAM by using the boot buffersize global configuration command. Because the change does not take effect until the switch reloads, the running configuration is lost and must be re-entered after the reload.

The workaround is to use the boot buffersize global configuration command to increase the size of the simulated NVRAM and then to reload the switch before applying the switch configuration.

The switch might reload when it is executing the no snmp-server host global configuration command. This is a rare condition that can happen if SNMP traps or informs are enabled and the SNMP agent attempts to send a trap to the host just as it is being removed from the configuration and if the IP address of the host (or the gateway to reach the host) has not been resolved by Address Resolution Protocol (ARP).

The workaround is to ensure that the target host or the next-hop gateway to that host is in the ARP cache (for example, by issuing a ping command) before removing it from the SNMP configuration.

Alternatively, disable all SNMP traps and informs before removing any hosts from the SNMP configuration.

A Gigabit fiber link might be disabled because of UniDirectional Link Detection (UDLD) if QoS is enabled on the interface and the bandwidth allocations prevent the transmission or reception of the UDLD frames.

The workaround is to disable UDLD on the affected interface.

When the switch is configured with login authentication with local usernames, memory use increases by 192 bytes with each login to the switch.

The workaround is to configure authentication, authorization, and accounting (AAA) authentication with the aaa new-model global configuration command and use the aaa authentication login global configuration command to configure login authentication methods.

SNMP returns errors or zero values for 64-bit counters in the IF-MIB.

The IF-MIB definition includes several objects of the type Counter64. Support for these objects has not yet been implemented on the Catalyst 3550 switch.

There is no workaround.

Packets denied by an output access list or a VLAN map on an output VLAN might be forwarded to the CPU for processing rather than dropped by hardware resources in the Catalyst 3550 if all these conditions are true:

Two possible workarounds exist:

When a GBIC port that has a GigaStack GBIC module installed is administratively down, you cannot bring up the link by using the no shutdown interface configuration command.

The workaround is to remove and re-insert the GigaStack GBIC.

Open Cluster Caveats

This section describes the severity 3 cluster configuration caveats:

When executing a remote command on a Catalyst 3550 member switch from a command switch that is not a Catalyst 3550 switch, if the command generates a lot of output and the output is paused and restarted, communication between the two switches might halt.

The workaround is to follow the documented cluster configuration guidelines, which recommend using a Catalyst 3550 switch as the command switch in mixed-model clusters.

The cluster setup privileged EXEC command, which is supposed to automatically build a cluster, can generate erroneous configuration scripts that do not form valid switch clusters.

The workaround when configuring clustering is to use CMS or the appropriate cluster global configuration commands to configure switch clustering.

Open Cluster Management Suite Caveats

This section describes the severity 3 CMS configuration caveats:

CMS performance degrades if the Topology View is open for several hours on a Solaris machine. The cause might be a memory leak.

The workaround is to close the browser, reopen it, and launch CMS again.

If you are printing a Topology View or Front Panel View that contains many devices and are running Solaris 2.6 with JDK1.2.2, you might get an Out of Memory error message.

The workaround is to close the browser, re-open it, and launch CMS again. Before you perform any other task, bring up the view that you want to print, and click Print in the CMS menu.

If you try to enable Port Fast on an interface that does not accept it—a trunk port, for example—no message warns you that Port Fast was not enabled.

There is no workaround.

If you select multiple FastEthernet ports on a Catalyst 3550 switch, the speed of 1000 Mbps is shown as an option in the Modify Port Settings window. Ignore this speed option.

You cannot modify the multicast groups that are shown in the IGMP Snooping window.

The workaround is to delete the group that you want to modify and then recreate it with the change that you want.

In the Port Statistics window, the statistics might appear on the wrong ports.

There is no workaround.

When an IP phone is connected to Customer Premise Equipment (CPE) that is connected to a Catalyst 2900-LRE-XL switch and Topology View is used to view the network, the IP phone is shown by itself without any connectivity to the CPE devices. This only happens when the IP phone is connected to a CPE; it does not happen if the IP phone is connected directly to a switch.

There is no workaround.

Resolved Caveats

This section describes caveats that have been resolved:

Resolved IOS Caveat in Release 12.1(8)EA1c

This IOS caveat was resolved in IOS Release 12.1(8)EA1c:

The switch no longer generates the debug message max_vbl_size_outgoing < 0 !! and initiates a traceback on the console when a tweaked SNMP packet is received.

Resolved Cluster Management Suite Caveat in Release 12.1(8)EA1c

This Cluster Management Suite caveat was resolved in IOS Release 12.1(8)EA1c:

A command switch no longer fails when it receives SNMP packets that have invalid variable bindings.

Resolved IOS Caveats in Release 12.1(8)EA1b

These IOS configuration caveats were resolved in IOS release 12.1(8)EAlb:

The Catalyst 3550 switch now uses the time period specified in a general multicast query instead of the configured MVR query response time to prune member ports, and there is no traffic disruption during general query intervals.

This message, where dec represents an internal implementation value in hexadecimal, is no longer incorrectly displayed when the CPU is forwarding a large number of frames:

    ETHCNTR-3-UNEXPECTED_EVENT: Request [dec] encountered event 1 in state 2
If you enter a global configuration mode command while in interface range configuration mode, this no longer causes the switch to reset if that global configuration mode command causes the parser to enter a submode of global configuration mode.

Pause frame counters are now displayed with the show interfaces interface-id privileged EXEC command.

You can now configure the cluster SNMP traps by using the snmp-server host global configuration command through the CLI, and you can monitor SNMP traps for the cluster on the Catalyst 3550 switch.

If you change an active QoS ACL or change an active class map to use a different ACL when the QoS ternary content addressable memory (TCAM) region is nearly full, the QoS ACL entries in the TCAM are not corrupted, and ACL based QoS classification behaves correctly on the switch.

When a Catalyst 3550 switch is redundantly connected to a network where the links to the Catalyst 3550 switch are misconfigured to be trunking with ISL encapsulation and the Catalyst 3550 switch is not trunking, ISL traffic is no longer flooded or dropped.

The switch now rejects QoS policer configurations beyond what it can support. The switch supports a policer traffic rate up to 1,000,000,000 bps even though the help string for the police rate-bps burst-byte [exceed-action {drop | policed-dscp-transmit}] policy-map class configuration command shows the traffic-rate range as 8,000 to 2,000,000,000. The switch can support a policer burst size up to 2,000,000 bytes, even though the help string for the police rate-bps burst-byte [exceed-action {drop | policed-dscp-transmit}] policy-map class configuration command shows the burst-size range as 8,000 to 512,000,000.

If you configure a policy map with class statements that match both a MAC ACL and an IP ACL (by using the match access-group acl-index-or-name class-map configuration command) and then remove the classes that match one protocol by using the no class class-map-name policy-map configuration command, the policy map is no longer detached from the interface.

If an IGMP group leave message is received within the query response interval after a general query, the group leave message is no longer ignored, and the pruning of member ports is not delayed until the next general query.

Changing the system MTU by using the system mtu global configuration command when there is a tunnel interface or loopback interface configured on the switch no longer causes the switch to reload.

An error can occur with management protocol processing. Please use the following URL for further information:

http://www.cisco.com/cgi-bin/bugtool/onebug.pl?bugid=CSCdw65903

Resolved Cluster Caveat in Release 12.1(8)EA1b

This cluster configuration caveat was resolved in IOS Release 12.1(8)EA1b:

When a switch is connected to the cluster command switch through a routed port, you are now able to add it to the cluster.

Resolved Cluster Management Suite Caveats in Release 12.1(8)EA1b

These Cluster Management Suite caveats were resolved in IOS Release 12.1(8)EA1b:

If you enable the STP bridge protocol data unit (BPDU) guard feature on a switch, also enable Port Fast on a port that connects to that switch, and then disconnect and reconnect that switch, you can now refresh the GUI without problems.

The device manager now launches properly if the HTTP port for the command switch is other than 80.

If you select an HSRP group in the Router Redundancy window and click Delete, the group is now correctly deleted.

You can now use CMS to configure dynamic-access ports on Catalyst 2900 XL switches that run IOS Release 11.2(8.6)SA6.

The burst rate and burst size that you request with the QoS wizard no longer appear to be configured incorrectly when you display them in the Policy Details window.

Documentation Updates

You can access all Catalyst 3550 documentation at this URL:

http://www.cisco.com/univercd/cc/td/doc/product/lan/c3550/index.htm

This section provides updates to the product documentation. These changes will be included in the next version of the documentation.

Errors

In the Catalyst 3550 Hardware Installation Guide, the model numbers for the Catalyst 3550-24 switches and the Catalyst 3550-48 are incorrect. These are the correct model numbers:

The SMI designation means that the switch ships with the standard multilayer software image (Layer 2+ features); the EMI designation means the switch ships with the enhanced multilayer software image (Layer 2+ and Layer 3 features.)

Additions

These additions have not yet been included in Catalyst 3550 documentation.

Korean Regulatory Statement

This Korean regulatory statement for the Catalyst 3550-12T and Catalyst 3550-12G switches has not yet been included in the Catalyst 3550 Multilayer Switch Hardware Installation Guide:


Warning This is a Class A Device and is registered for EMC requirements for industrial use. The seller or buyer should be aware of this. If this type was sold or purchased by mistake, it should be replaced with a residential-use type.


Adding a VTP Client to a VTP Domain

Before adding a VTP client to a VTP domain, always verify that its VTP configuration revision number is lower than the configuration revision number of the other switches in the VTP domain. If necessary, reset the switch configuration revision number to 0.


Caution   Switches in a VTP domain always use the VLAN configuration of the switch with the highest VTP configuration revision number. If you add a switch that has a revision number higher than the revision number in the VTP domain, it can erase all VLAN information from the VTP server and VTP domain.

Beginning in privileged EXEC mode, follow these steps to verify and reset the VTP configuration revision number on a switch before adding it to a VTP domain:

Command Purpose

Step 1 

show vtp status

Check the VTP configuration revision number.

If the number is 0, add the switch to the VTP domain.

If the number is greater than 0, follow these steps:

       a. Write down the domain name.

       b. Write down the configuration revision number.

       c. Continue with the next steps to reset the configuration revision number on the switch.

Step 2 

vlan database

Enter VLAN configuration mode.

Step 3 

vtp domain domain-name

Change the domain name from the original one displayed in Step 1 to a new name.

Step 4 

exit

The VLAN information on the switch is updated and the configuration revision number is reset to 0. You return to privileged EXEC mode.

Step 5 

show vtp status

Verify that the configuration revision number has been reset to 0.

Step 6 

vlan database

Enter VLAN configuration mode.

Step 7 

vtp domain domain-name

Enter the original domain name on the switch.

Step 8 

exit

The VLAN information on the switch is updated, and you return to privileged EXEC mode.

Step 9 

show vtp status

(Optional) Verify that the domain name is the same as in Step 1 and that the configuration revision number is 0.

After you have reset the configuration revision number, you can add the switch to the VTP domain.


Note   You can use the vtp transparent VLAN configuration command to disable VTP on the switch and then change its VLAN information without affecting the other switches in the VTP domain. For more information about using VTP transparent mode, refer to the Catalyst 3550 Multilayer Switch Software Configuration Guide.

Related Documentation

These documents provide complete information about the switch and are available from this Cisco.com site:

http://www.cisco.com/univercd/cc/td/doc/product/lan/c3550/index.htm

You can order printed copies of documents with a DOC-xxxxxx= number from the Cisco.com sites and from the telephone numbers listed in the "Ordering Documentation" section.

Obtaining Documentation

The following sections explain how to obtain documentation from Cisco Systems.

World Wide Web

You can access the most current Cisco documentation on the World Wide Web at the following URL:

http://www.cisco.com

Translated documentation is available at the following URL:

http://www.cisco.com/public/countries_languages.shtml

Documentation CD-ROM

Cisco documentation and additional literature are available in a Cisco Documentation CD-ROM package, which is shipped with your product. The Documentation CD-ROM is updated monthly and may be more current than printed documentation. The CD-ROM package is available as a single unit or through an annual subscription.

Ordering Documentation

Cisco documentation is available in the following ways:

http://www.cisco.com/cgi-bin/order/order_root.pl

http://www.cisco.com/go/subscription

Documentation Feedback

If you are reading Cisco product documentation on the World Wide Web, you can send us your comments by completing the online survey. When you display the document listing for this platform, click Give Us Your Feedback.

You can e-mail your comments to bug-doc@cisco.com.

To submit your comments by mail, use the response card behind the front cover of your document, or write to the following address:

Cisco Systems, Inc.
Attn: Document Resource Connection
170 West Tasman Drive
San Jose, CA 95134-9883

We appreciate your comments.

Obtaining Technical Assistance

Cisco provides Cisco.com as a starting point for all technical assistance. Customers and partners can obtain documentation, troubleshooting tips, and sample configurations from online tools by using the Cisco Technical Assistance Center (TAC) Web Site. Cisco.com registered users have complete access to the technical support resources on the Cisco TAC Web Site.

Cisco.com

Cisco.com is the foundation of a suite of interactive, networked services that provides immediate, open access to Cisco information, networking solutions, services, programs, and resources at any time, from anywhere in the world.

Cisco.com is a highly integrated Internet application and a powerful, easy-to-use tool that provides a broad range of features and services to help you to

You can self-register on Cisco.com to obtain customized information and service. To access Cisco.com, go to the following URL:

http://www.cisco.com

Technical Assistance Center

The Cisco TAC is available to all customers who need technical assistance with a Cisco product, technology, or solution. Two types of support are available through the Cisco TAC: the Cisco TAC Web Site and the Cisco TAC Escalation Center.

Inquiries to Cisco TAC are categorized according to the urgency of the issue:

Which Cisco TAC resource you choose is based on the priority of the problem and the conditions of service contracts, when applicable.

Cisco TAC Web Site

The Cisco TAC Web Site allows you to resolve P3 and P4 issues yourself, saving both cost and time. The site provides around-the-clock access to online tools, knowledge bases, and software. To access the Cisco TAC Web Site, go to the following URL:

http://www.cisco.com/tac

All customers, partners, and resellers who have a valid Cisco services contract have complete access to the technical support resources on the Cisco TAC Web Site. The Cisco TAC Web Site requires a Cisco.com login ID and password. If you have a valid service contract but do not have a login ID or password, go to the following URL to register:

http://www.cisco.com/register/

If you cannot resolve your technical issues by using the Cisco TAC Web Site, and you are a Cisco.com registered user, you can open a case online by using the TAC Case Open tool at the following URL:

http://www.cisco.com/tac/caseopen

If you have Internet access, it is recommended that you open P3 and P4 cases through the Cisco TAC Web Site.

Cisco TAC Escalation Center

The Cisco TAC Escalation Center addresses issues that are classified as priority level 1 or priority level 2; these classifications are assigned when severe network degradation significantly impacts business operations. When you contact the TAC Escalation Center with a P1 or P2 problem, a Cisco TAC engineer will automatically open a case.

To obtain a directory of toll-free Cisco TAC telephone numbers for your country, go to the following URL:

http://www.cisco.com/warp/public/687/Directory/DirTAC.shtml

This document is to be used in conjunction with the document listed in the "Related Documentation" section.

CCIP, the Cisco Powered Network mark, the Cisco Systems Verified logo, Cisco Unity, Fast Step, Follow Me Browsing, FormShare, Internet Quotient, iQ Breakthrough, iQ Expertise, iQ FastTrack, the iQ Logo, iQ Net Readiness Scorecard, Networking Academy, ScriptShare, SMARTnet, TransPath, and Voice LAN are trademarks of Cisco Systems, Inc.; Changing the Way We Work, Live, Play, and Learn, Discover All That's Possible, The Fastest Way to Increase Your Internet Quotient, and iQuick Study are service marks of Cisco Systems, Inc.; and Aironet, ASIST, BPX, Catalyst, CCDA, CCDP, CCIE, CCNA, CCNP, Cisco, the Cisco Certified Internetwork Expert logo, Cisco IOS, the Cisco IOS logo, Cisco Press, Cisco Systems, Cisco Systems Capital, the Cisco Systems logo, Empowering the Internet Generation, Enterprise/Solver, EtherChannel, EtherSwitch, GigaStack, IOS, IP/TV, LightStream, MGX, MICA, the Networkers logo, Network Registrar, Packet, PIX, Post-Routing, Pre-Routing, RateMUX, Registrar, SlideCast, StrataView Plus, Stratm, SwitchProbe, TeleRouter, and VCO are registered trademarks of Cisco Systems, Inc. and/or its affiliates in the U.S. and certain other countries.

All other trademarks mentioned in this document or Web site are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other company. (0201R)

Copyright © 2002, Cisco Systems, Inc.
All rights reserved.


hometocprevnextglossaryfeedbacksearchhelp
Posted: Sat Jul 6 15:38:32 PDT 2002
All contents are Copyright © 1992--2002 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.