cc/td/doc/product/lan/c3550/12120ea1
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Technical Specifications

Technical Specifications


This appendix lists the switch technical specifications in Table A-1 to Table A-5. The regulatory agency approvals are in Table A-6.

Table A-1   Switch Environmental and Physical Specifications

Environmental Ranges

Operating temperature

32 to 113° F (0 to 45° C)

Storage temperature

-13 to 158° F (-25 to 70° C)

Relative humidity

10 to 85% (noncondensing)

Operating altitude

Up to 10,000 ft (3049 m)

Storage altitude

Up to 15,000 ft (4573 m)

Physical Specifications

Weight

Catalyst 3550-12T and 3550-12G: 16 lb (7.26 kg)

Catalyst 3550-24: 11 lb (5 kg)

Catalyst 3550-24-DC and 3550-24-FX:
10.5 lb (4.8 kg)

Catalyst 3550-24PWR: 14 lb (6.35 kg)

Catalyst 3550-48: 13 lb (5.9 kg)

Physical Specifications

Dimensions (H x D x W)

Catalyst 3550-12T and 3550-12G:
2.63 x 15.9 x 17.5 in. (6.68 x 40.39 x 44.45 cm)

Catalyst 3550-24 and 3550-24-DC:
1.75 x 14.4 x 17.5 in. (4.45 x 36.58 x 44.45 cm)

Catalyst 3550-24-FX and 3550-48:
1.75 x 16.25 x 17.5 in. (4.45 x 41.28 x 44.45 cm)

Catalyst 3550-24PWR:
1.73 x 17.35 x 17.5 in. (4.4 x 44 x 44 cm)

Table A-2   Power Requirements for the Catalyst 3550-12T, 3550-12G, 3550-24, 3550-24-FX, and 3550-48 Switches

Power Requirements

AC input voltage

Catalyst 3550-12T and 3550-12G:
100 to 127/200 to 240 VAC (autoranging)
2.0 A/1.0 A, 50 to 60 Hz

Catalyst 3550-24, 3550-24-FX, and 3550-48:
100 to 127/200 to 240 VAC (autoranging)
1.6 A/0.9 A, 50 to 60 Hz

DC input voltages for RPS 300

Catalyst 3550-12T and 3550-12G: +12 V@13 A

Catalyst 3550-24: +12 V@8.5 A

Catalyst 3550-24-FX: +12 V@8.5 A

Catalyst 3550-48: +12 V@13 A

Power Requirements

DC input voltages for RPS 675

+12 V@25 A

Power consumption

Catalyst 3550-12T and 3550-12G: 190 W, 650 Btus per hour

Catalyst 3550-24: 65 W, 222 Btus per hour

Catalyst 3550-24-FX: 85 W, 290 Btus per hour

Catalyst 3550-48: 110 W, 375 Btus per hour

Table A-3   Power Requirements for the Catalyst 3550-24PWR Switch

Power Requirements

AC input voltage

100 to 127/200 to 240 VAC (autoranging)
5.5A/2.8 A, 50 to 60 Hz

DC input voltages for RPS 300

+12 V@7.5 A, -48V@7.8 A

DC input voltages for RPS 675

+12 V@25 A, -48V@7.8 A

Power consumption

525 W, 1790 Btus per hour

Table A-4   Power Requirements for the Catalyst 3550-24-DC

Power Requirements

Power consumption

55 W, 190 Btus per hour

DC input voltage

-36 to -72 VDC

DC input voltages for RPS 675

+12 V@13 A

Wire gauge for power connection

18 AWG (6 AWG for protective earth)

Branch circuit protection

5 A

Table A-5   Fiber-Port Specifications for Catalyst 3550-24-FX Switches

Fiber-Port Power Levels

 

Optical transmitter wavelength

1300 nm1

Optical receiver sensitivity for 50/125-micron cabling

-33.5 to -11.8 dBm2

Optical receiver sensitivity for 62.5/125-micron cabling

-33.5 to -11.8 dBm

Optical transmitter power for 50/125-micron cabling

-23.5 to -14 dBm

Optical transmitter power for 62.5/125-micron cabling

-20 to -14 dBm

nm = nanometers

dBm = decibel milliwatt

Table A-6   Catalyst 3550 Switch Agency Approvals

Safety  EMC 

UL to UL 60950, Third Edition

FCC Part 15 Class A

c-UL to CAN/CSA -C22.2 No. 60950-00, Third Edition

EN 55022 Class A (CISPR 22 Class A)

TUV/GS to EN 60950:2000

VCCI Class A

CB to IEC 60950 with all country deviations

AS/NZS 3548 Class A

NOM to NOM-019-SCFI

BSMI

CE Marking

CE Marking

NEBS1

EN55024

Bellcore GR-1089-CORE

EN50082-1

Bellcore GR-63-CORE

 

Bellcore GR-1089-CORE

 

Only Catalyst 3550-24-DC switch


hometocprevnextglossaryfeedbacksearchhelp
Posted: Mon Feb 9 09:04:54 PST 2004
All contents are Copyright © 1992--2004 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.