cc/td/doc/product/lan/c2900xl/29_35xu
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Technical Specifications

Technical Specifications

Table A-1, Table A-2, and Table A-3, list the technical specifications for the Catalyst 3500 series XL switches. Table A-4 lists the regulatory agency approvals.

 


Table A-1: Technical Specifications for the Catalyst 3508G XL Switch
Environmental Ranges

Operating temperature

32 to 113°F (0 to 45°C)

Storage temperature

-4 to 149°F (-10 to 65°C)

Operating humidity

10 to 85% (noncondensing)

Operating altitude

Up to 10,000 ft (3000 m)

Storage altitude

Up to 15,000 ft (4570 m)

Power Requirements

AC input voltage

100 to 127/200 to 240 VAC
(autoranging) 50 to 60 Hz

DC input voltages

+3.3V

@14A,
+12V


@3A

Power consumption

82.2W
280 Btus per hour

Physical Dimensions

Weight

12 lb (5.45 kg)

Dimensions (H x W x D)

1.75 x 16 x 17.5 in.
(4.45 x 40.46 x 44.45 cm)

    
Table A-2: Technical Specifications for the Catalyst 3512, 3524, and 3548 XL Switches
Catalyst 3512 XL Catalyst 3524 XL Catalyst 3548 XL
Environmental Ranges

Operating temperature

32 to 113°F (0 to 45°C)

32 to 113°F (0 to 45°C)

32 to 113°F (0 to 45°C)

Storage temperature

-4 to 149°F (-10 to 65°C)

-4 to 149°F (-10 to 65°C)

-4 to 149°F (-10 to 65°C)

Relative humidity

10 to 85% (noncondensing)

10 to 85% (noncondensing)

10 to 85% (noncondensing)

Operating altitude

Up to 10,000 ft (3000 m)

Up to 10,000 ft (3000 m)

Up to 10,000 ft (3000 m)

Storage altitude

15,000 ft (4570 m)

15,000 ft (4570 m)

15,000 ft (4570 m)

Power Requirements

AC input voltage

100 to 127/200 to 240 VAC
(autoranging) 50 to 60 Hz

100 to 127/200 to 240 VAC
(autoranging) 50 to 60 Hz

100 to 127/200 to 240 VAC
(autoranging) 50 to 60 Hz

DC input voltages

+5V

@8.0A,
+12V


@0.5A

+5V

@10A,
+12V


@0.5A

+3.3V

@17A
+12V


@1.1A

Power consumption

50W
171 Btus per hour

75W
256 Btus per hour

100W
600 Btus per hour

Physical Dimensions

Weight

10.25 lb (4.65 kg)

8.5 lb (3.86 kg)

12 lb (5.45 kg)

Dimensions (H x D x W)

1.75 x 11.82 x 17.5 in.
(4.45 x 30.02 x 44.45 cm)

1.75 x 11.82 x 17.5 in.
(4.45 x 30.02 x 44.45 cm)

1.73 x 15.34 x 17.5 in
(4.39 x 39.0 x 44.45 cm)

   
Table A-3: Technical Specifications for the Catalyst 3524-PWR XL Switch
Environmental Ranges

Operating temperature

32 to 113°F (0 to 45°C)

Storage temperature

-4 to 149°F (-10 to 65°C)

Operating humidity

10 to 85% (noncondensing)

Operating altitude

Up to 10,000 ft (3000 m)

Storage altitude

Up to 15,000 ft (4570 m)

Power Requirements

AC input voltage

100 to 127/200 to 240 VAC
(autoranging) 50 to 60 Hz

DC input voltages

-48V

@3A,
+12V


@6A

Power consumption

325W1
1100 Btus per hour

Physical Dimensions

Weight

10.25 lb (4.65 kg)

Dimensions (H x W x D)

1.75 x 11.82 x 17.5 in.
(4.45 x 30.02 x 44.45 cm)

1The actual power consumption depends on the number of IP phones connected. 325W represents 24 IP phones connected.
   


Table A-4: Catalyst 3500 Series XL Agency Approvals
Safety EMC

UL to UL 1950, Third Edition

FCC Part 15 Class A

c-UL to CAN/CSA 22.2 No. 950-95, Third Edition

EN 55022 Class A (CISPR 22 Class A)

TUV/GS to EN 60950 with Amendment A1-A4 and A11

VCCI Class A

ACA/A2LA to AS/NZS 3260 and TS001-1997

AS/NZS 3548 Class A

CB to IEC 60950 with all country deviations

BSMI

NOM to NOM-019-SCFI

CE Marking

CE Marking


hometocprevnextglossaryfeedbacksearchhelp
Posted: Thu May 18 16:20:17 PDT 2000
Copyright 1989 - 2000©Cisco Systems Inc.