cc/td/doc/product/lan/c2900xl/29_35wc
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Technical Specifications

Technical Specifications

Table A-1, Table A-2, Table A-3, and Table A-4 list the technical specifications for the Catalyst  2900 series switches.

For switches that support modules (Catalyst 2912MF XL and 2924M XL), also refer to the Catalyst 2900 Series XL Modules Installation Guide and the Catalyst 2900 Series XL ATM Modules Installation Guide for additional specifications.

Table A-5 lists the agency approvals for EMI and safety.


Table A-1: Technical Specifications for the Catalyst 2912 XL and Catalyst 2912MF XL Switches

Catalyst 2912 XL Catalyst 2912MF XL
Environmental Ranges

Operating temperature

32 to 113°F (0 to 45°C)

32 to 113°F (0 to 45°C)

Storage temperature

-4 to 149°F (-10 to 65°C)

-4 to 149°F (-10 to 65°C)

Operating humidity

10 to 85% (noncondensing)

10 to 85% (noncondensing)

Operating altitude

Up to 10,000 ft (3000 m)

Up to 10,000 ft (3000 m)

Storage altitude

Up to 15,000 ft (4570m)

Up to 15,000 ft (4570 m)

Power Requirements

AC input voltage

100 to 127/200 to 240 VAC (autoranging) 50 to 60 Hz

100 to 127/200 to 240 VAC (autoranging) 50 to 60 Hz

DC input voltages

+5V

@9A, +12V


@0.5A

+5V

@12A, +12V


@0.75A

+5V


@22A, +12V


@0.75A
with two modules installed

Power consumption

70W (maximum)

239 Btus per hour

90W (maximum)
307 Btus per hour

170W with two modules installed
580 Btus per hour

Physical Dimensions

Weight

7 lb (3.2 kg)

14 lb (6.3 kg)

15.5 lb (7.1 kg) with two modules installed

Dimensions (H x W x D)

1.73 x 17.5 x 9.79 in.
(4.4 x 44.5 x 24.8 cm)

3.46 x 17.5 x 12 in.
(8.8 x 44.5 x 30.5 cm)

  
Table A-2: Technical Specifications for the Catalyst 2924 XL and Catalyst 2924C XL Switches

Catalyst 2924 XL Catalyst 2924C XL
Environmental Operating Ranges

Operating temperature

32 to 113°F (0 to 45°C)

32 to 113°F (0 to 45°C)

Storage temperature

-4 to 149°F (-10 to 65°C)

-4 to 149°F (-10 to 65°C)

Operating humidity

10 to 85% (noncondensing)

10 to 85% (noncondensing)

Operating altitude

Up to 10,000 ft (3000 m)

Up to 10,000 ft (3000 m)

Storage altitude

Up to 15,000 ft (4570 m)

Up to 15,000 ft (4570 m)

Power Requirements

AC input voltage

100 to 127/200 to 240 VAC
(autoranging) 50 to 60 Hz

100 to 127/200 to 240 VAC
(autoranging) 50 to 60 Hz

DC input voltages

+5V

@9A, +12V


@0.5A

+5V

@9A, +12V


@0.5A

Power consumption

70W (maximum)

239 Btus per hour

70W (maximum)

239 Btus per hour

Physical Dimensions

Weight

7 lb (3.2 kg)

7 lb (3.2 kg)

Dimensions (H x W x D)

1.73 x 17.5 x 9.79 in.
(4.4 x 44.5 x 24.8 cm)

1.73 x 17.5 x 9.79 in.
(4.4 x 44.5 x 24.8 cm)

Fiber-Port Power Levels

Optical transmitter wavelength

1300 nm1

Optical sensibility of the receiver

-14 dBm2

Optical power transmitter

-19 to -14 dBm

Transmit

-19 to -14 dBm

1nm = nanometers
2dBm = decibel milliwatt
  
Table A-3: Technical Specifications for the Catalyst 2924M XL Switches
Environmental Operating Ranges

Operating temperature

32 to 113°F (0 to 45°C)

Storage temperature

-4 to 149°F (-10 to 65°C)

Operating humidity

10 to 85% (noncondensing)

Operating altitude

Up to 10,000 ft (3000 m)

Storage altitude

Up to 15,000 ft (4570 m)

Power Requirements

AC input voltage

100 to 127/200 to 240 VAC
(autoranging) 50 to 60 Hz

DC input voltages

+5V

@12A, +12V


@0.55A

+5V


@22A, +12V


@0.75A
with two modules installed

Power consumption

90W (maximum)
307 Btus per hour

170W with two modules installed
580 Btus per hour

Physical Dimensions

Weight

13.5 lb (6.12 kg)

15 lb (6.8 kg) with two modules installed

Dimensions (H x W x D)

3.46 x 17.5 x 12 in.
(8.8 x 44.5 x 30.5 cm)


Table A-4: Technical Specifications for the Catalyst 2912 LRE XL and 2924 LRE XL Switches
Environmental Operating Ranges

Operating temperature

32 to 113°F (0 to 45°C)

Storage temperature

-13 to 158°F (-25 to 70°C)

Operating humidity

10 to 85% (noncondensing)

Operating altitude

Up to 10,000 ft (3000 m)

Storage altitude

Up to 15,000 ft (4570 m)

Power Requirements

AC input voltage

100 to 127/200 to 240 VAC
(autoranging) 50 to 60 Hz

DC input voltages

+12V

@12A

Power consumption

150W

Physical Dimensions

Weight

8.75 (4.00 kg)

Dimensions (H x W x D)

1.75 x 11.82 x 12 in
(4.45 x 30.02 x 30.48 cm)


Table A-5: Catalyst 2900 Series XL Agency Approvals
Safety EMI

UL 1950/CSA 22.2 No. 950

FCC Part 15 Class A

IEC 950/EN 60950

EN 55022 Class A (CISPR 22 Class A)

AS/NZS 3260, TS001

VCCI Class A

CE

AS/NZS 3548 Class A

BCIQ

CE


hometocprevnextglossaryfeedbacksearchhelp
Posted: Wed Feb 6 09:03:43 PST 2002
All contents are Copyright © 1992--2002 Cisco Systems, Inc. All rights reserved.