Introduction

The Cisco 6100/6130 digital subscriber line access multiplexer (DSLAM) is a central office (CO) grade multiplexer that offers cost effective, high-speed services to the residential, telecommuter, and business markets. The Cisco 6100/6130 system is part of the Cisco leadership architecture that transcends the DSL service profitability barrier.

The Cisco 6100/6130 DSLAM

Module Software Versions for Release 3.1.0

Table 1 contains the individual module software versions (and ROM versions, as applicable) that the system part number SF-6100-3.1.0 comprises for Release 3.1.0.


Table 1: Software Versions for Release 3.1.0
Release 3.1.0 Component Software Version

System controller module software

9651-001-41

NI-1 module software

9601-001-34

DS3 STM1 software

9601-005-13

CAP ATU-C module software

9101-001-30

DMT-2 ATU-C module main software

9101-003-08

DMT-2 ATU-C module DSP2 software

5385-579-97

STU-C module software

9101-008-05

Flexi ATU-C module software (DMT mode)

9101-005-11

Flexi ATU-C module software (CAP mode)

9101-004-11

LIM3 controller module software

9651-002-12

RDF4

9100-003-25

1STM = subtending host module
2DSP = digital signal processor
3LIM = line interface module
4RDF = release definition file

The ViewRunner management software (ViewRunner for Windows or ViewRunner for HP OpenView) Release 3.x.x is required to fully support the feature set of the Cisco 6100/6130 with NI-1 system Release 3.1.0.

To determine the module software versions, use the ViewRunner management software.


Note   To upgrade from version 2.x.x to version 3.x.x of the Cisco 6100/6130 node software, you must use ViewRunner version 3.0.0 software.

Hardware and Software Compatibility

This section details the compatibility of the following Cisco 6100 Series system elements:

ViewRunner Management and Cisco 6100/6130 with NI-1 Software Compatibility

Table 2 summarizes the compatibility among Cisco 6100 Series system and ViewRunner management software releases.


Table 2: ViewRunner Management Software and Cisco 6100/6130 with NI-1 System Release Compatibility
Cisco 6100/6130 with NI-1 System Release1,2
3.1.0 3.0.0 2.4.2 2.4.1 2.4.0 2.3.x 2.2.1/2.2.5 2.2.0
ViewRunner for Windows Release

3.1.0

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

3.0.0

Yes3

Yes

Yes

Yes

Yes

Yes

Yes

Yes

2.4.1

No

No

Yes

Yes

Yes

No

No

No

2.4.0

No

No

No

No

Yes

No

No

No

2.3.5

No

No

No

No

No

Yes3

Yes

Yes

2.3.0

No

No

No

No

No

No

Yes3

Yes

2.2.1

No

No

No

No

No

No

Yes

Yes

2.2.0

No

No

No

No

No

No

No

Yes

ViewRunner for HP OpenView Release

3.1.0

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

3.0.0

Yes3

Yes

Yes

Yes

Yes

Yes

Yes

Yes

2.4.1

No

No

Yes

Yes

Yes

Yes

Yes

Yes

2.4.0

No

No

No

No

Yes

Yes

Yes

Yes

2.3.5

No

No

No

No

No

Yes3

Yes

Yes

2.3.0

No

No

No

No

No

No

Yes3

Yes

2.2.0

No

No

No

No

No

No

No

Yes

1The Cisco 6130 chassis feature support is present in Release 2.4.0 or later.
2Systems with a Cisco 6100 installed must connect to the network through a POTS splitter. Therefore, a Cisco 6100 cannot support a Direct Connect without a POTS splitter configuration.
3The most recent FCM file may be required. ViewRunner will detect and display a warning if a newer FCM is required.


Note   Cisco recommends upgrading the ViewRunner management software as new releases become available.

Cisco 6100/6130 with NI-1 Chassis and Configuration Compatibility

There are two different chassis available with the Cisco 6100/6130 with NI-1 system:

Table 3 shows the configurations in which each of the chassis can be used.


Table 3: Cisco 6100/6130 with NI-1 System Chassis and Configuration Compatibility
Chassis Direct Connect with a POTS Splitter Configuration Direct Connect Without a POTS Splitter Configuration DOH Configuration
With a Cisco 6120 With a Siecor POTS Splitter1

Cisco 61302

Yes

Yes

Yes

No

Cisco 61003

Yes

Yes

No

Yes

1The Siecor ADSL POTS Splitter Rack-Mount Shelf is compatible with the Cisco 6100 and Cisco 6130 chassis. The Siecor POTS splitter provides secondary lightning protection from tip to ring. However, secondary lightning protection is not provided from tip to ground or ring to ground.
2The Cisco 6130 chassis feature support is present in Release 2.4.0 or later.
3Systems with a Cisco 6100 installed must connect to the network through a POTS splitter (Cisco 6120 or Siecor POTS splitter). Therefore, a Cisco 6100 cannot support a Direct Connect without a POTS splitter configuration.

Module Compatibility

Following are the four types of Cisco 6100/6130 modules:

Table 4 shows the configurations where the Cisco 6100/6130 modules can operate.


Table 4: Cisco 6100 Series Module and Configuration Compatibility
Module Direct Connect with a POTS Splitter Configuration Direct Connect Without a POTS Splitter Configuration DOH Configuration1 Siecor POTS Splitter2
Cisco 6130 Cisco 6100 Cisco 6130 Cisco 6100 Cisco 6130 Cisco 6100

Dual-port CAP ATU-C

No

Yes

No

No

No

Yes

Yes

Dual-port DMT-2 ATU-C3,4

Yes

Yes

Yes

No

No

No

Yes

Quad-port flexi ATU-C5

Yes

Yes

Yes

No

No

No

Yes

Quad-port STU-C6,7

No

No

Yes

No

No

No

No

1The DOH configuration feature is not supported in Release 2.4.x with a Cisco 6100 or a Cisco 6130.
2The Siecor ADSL POTS splitter is compatible with a Cisco 6100 or a Cisco 6130 in a Direct Connect with a POTS splitter configuration.
3
The DMT-2 ATU-C module feature support is not available for the Cisco 6100 chassis prior to Release 2.4.1.
4If you install DMT-2 ATU-C modules in the Cisco 6100/6130, you must install all DMT POTS modules in the POTS splitter chassis.
5The flexi ATU-C module feature support is present in Release 3.0.0 or later.
6Symmetrical digital subscriber line (SDSL) does not support POTS.
7The STU-C module feature support is present in Release 2.4.1 or later.

Table 5 shows interoperability between a variety of modules and Cisco's customer premises equipment (CPE).


Table 5: Cisco 6100 Series Module and CPE Compatibility
Module Recommended CPE Alternative CPE Works with Limitations

Quad-port flexi (CAP)

  • Cisco 678 CBOS 2.3.0

  • Cisco 675 CBOS 2.3.0

  • Cisco 675 CBOS 2.2.0
    (no 17 kilobaud/68 kilobaud)

  • Cisco 675 CBOS 2.1.0
    (no 17 kilobaud/68 kilobaud)

  • Cisco 675 CBOS 2.0.1
    (no 17 kilobaud/68 kilobaud)

Cisco 605 PCI 210 Production

Quad-port flexi (DMT)

Cisco 678 CBOS 2.3.0

None

Quad-port flexi
(DMT G.lite)

Cisco 678 CBOS 2.3.0

None

Dual-port CAP

  • Cisco 678 CBOS 2.3.0

  • Cisco 675 CBOS 2.3.0

  • Cisco 675 CBOS 2.2.0
    (no 17 kilobaud/68 kilobaud)

  • Cisco 675 CBOS 2.1.0
    (no 17 kilobaud/68 kilobaud)

  • Cisco 675 CBOS 2.0.1
    (no 17 kilobaud/68 kilobaud)

Cisco 605 PCI 210 Production

Dual-port DMT (ADI)

Cisco 677

Cisco 627

Dual-port DMT G.lite (ADI)

Not Supported

None

Quad-port STU-C

Cisco 673 (Ethernet to DSL)

Cisco 633 (Frame Relay to DSL)

New Features

This section details the new features for the following releases:

New Features in Release 3.1.0

This release consists of resolving open caveats and releasing software support for a newer version of the flexi ATU-C module hardware. For more information on these caveats, see the "Resolved Caveats" section.

Table 6 details the module intermixing configurations in a Cisco 6100/6130 chassis for Release 3.1.0.


Note   You can only intermix the flexi ATU-C (CAP) and the flexi ATU-C (DMT-2) modules in the same chassis half.


Table 6: Cisco 6100/6130 Module Intermixing
Module Combination Cisco 6100 Chassis Cisco 6130 Chassis

Dual-port DMT-2 ATU-C and
quad-port STU-C

Not supported

Supported

Dual-port DMT-2 ATU-C and
dual-port CAP ATU-C

Supported

Not supported

Dual-port CAP ATU-C and
quad-port flexi ATU-C (DMT mode)

Supported

Not supported

Dual-port CAP ATU-C and
quad-port flexi ATU-C (CAP mode)

Supported

Not supported

Dual-port DMT-2 and
quad-port flexi ATU-C (DMT mode)

Supported

Supported

Dual-port DMT-2 and
quad-port flexi ATU-C (CAP mode)

Supported

Supported

Dual-port CAP ATU-C and
quad-port STU-C

Not supported

Not supported

Quad-port flexi ATU-C (CAP mode) and quad-port flexi ATU-C (DMT mode)

Supported

Supported

Quad-port flexi ATU-C (CAP mode) and quad-port STU-C

Not supported

Supported

Quad-port flexi ATU-C (DMT mode) and quad-port STU-C

Not supported

Supported


Note   For a description of ViewRunner software features, refer to the Release Notes for ViewRunner for Windows Release 3.1.0 and the Release Notes for ViewRunner for HP OpenView Release 3.1.0.

New Features in Release 3.0.0


Note   Release 3.0.0 merges all of the features and functionality of Releases 2.4.x, 2.3.x, and 2.2.5 in addition to the features described in the following sections.

The following items are new node software features for Release 3.0.0. For feature details, refer to the Release Notes for the Cisco 6100 Series System Release 3.0.0 located on the World Wide Web at http://www.cisco.com/univercd/cc/td/doc/product/dsl_prod/c6100/relnotes/7810305.htm

Release 3.0.0 brings support for a new Cisco 6100/6130 module—the Cisco 6100 Series quad-port flexi ATU-C. Flexi refers to support for both DMT-2 modulation (ANSI T1.413 Issue 2), CAP modulation, and G.lite. The module is designed for ADSL over POTS through a POTS splitter or for a direct connection to the customer loop. Loop characteristics will determine the actual data rates.

A fan tray is required when you are using either of the following chassis:

A major alarm event occurs when a fan tray is not present. If you are installing more than one chassis, a fan tray must be installed under each chassis. For more information about the fan tray, refer to the Cisco 6130 with NI-1 Direct Connect Installation Guide or the Cisco 6100 with NI-1 Direct Connect Installation Guide.


Note   For more information on installing and using the quad-port flexi ATU-C module, see the Quad-Port Flexi ATU-C Module FRU Installation and Replacement Notes.

Limitations and Restrictions

The following limitations and restrictions apply to Release 3.0.0 and Release 3.1.0:


Table 7: Feature Comparison and Caveats—Dual-Port CAP ATU-C and Quad-Port Flexi CAP ATU-C Modules
Feature Dual-Port CAP ATU-C Module Quad-Port Flexi CAP ATU-C Module

Line Rate

Supported

Supported with caveat: Rarely CPE retrains at 952 instead of 1088 kbps upstream. (CSCdp85772)

Margin

Supported

Supported

PSD1

Supported

Supported

Reed-Solomon

Supported

Supported

136 kilobaud downstream

Supported

Supported

17 kilobaud and 68 kilobaud upstream

Supported

Supported

1PSD = power spectral density


Table 8: Feature Comparison and Caveats—Dual-port DMT-2 ATU-C and Quad-port Flexi DMT-2 ATU-C Modules
Feature Dual- Port DMT-2 ATU-C Module Quad-Port Flexi DMT-2 ATU-C Module

Line Rate

Supported with caveat: Cannot train upstream @ 128, 256, 512, 640, 768 kbps (CSCdm59472 and CSCdm81817)

Supported

Margin

Supported with caveat: Cannot set margin below 6. (CSCdm43638)

Supported

PSD

Supported with caveat: Always use default setting of -40 dbm/Hz. (CSCdm36644)

If you select the -46 dbm/Hz or the-49 dbm/Hz setting, the module uses the default setting of -40 dbm/Hz. (CSCdm69047)

Supported with caveat: All settings are mapped to full power (except -49 dbm/Hz) and will automatically attenuate down to a lower power when necessary.

Overhead Framing

Supported with the following settings:
0—Full, Asynchronous
1—Full, Synchronous
2—Reduced, Separate
3—Reduced, Merged

Supported with caveat:
3—Reduced, Merged
Modes 0, 1, and 2 are not supported at this time. (CSCdp39444)

Training Mode

Supported with caveat:
Standard only (CSCdm36621)

Supported with caveat:
Standard only (CSCdp53139)

Interleaved Delay

Supported with caveat:
0, 250, 500, 1 K, 2 K, 4 K, 8 K microseconds work, all other settings equal maximum. (CSCdm76074)

Supported with the following settings:
250, 500, 1 K, 2 K, 4 K, 8 K, 16 K, 32 K, 64 K microseconds. (CSCdr23589)

FEC1 Redundancy

Not supported (CSCdm23668)

Supported with the following settings:
0, 2, 4 ,6, 8, 12, 14, 16 bytes

Trellis Code

Supported with caveat: Trellis enabled causes data problems. (CSCdm69068)

Supported with caveat: Enable Trellis for rates over 7.6 Mbps. (CSCdp67298)

Bit Swapping

Not supported (CSCdm77285)

Not supported (CSCdp39437)

Latency Path

Supported with caveat:
Fast = Interleaved at 0 Delay.
(CSCdp27472)

Supported

1FEC = forward error correction

Important Notes

There are no important notes for Release 3.1.0.


Note   For important notes for Release 3.0.0, refer to the Release Notes for the Cisco 6100 Series System Release 3.0.0 located on the World Wide Web at http://www.cisco.com/univercd/cc/td/doc/product/dsl_prod/c6100/relnotes/7810305.htm

Open Caveats

The caveats listed in Table 9 are open as of Release 3.1.0.


Table 9: Open Caveats as of Release 3.1.0
DDTS Entry Description

CSCdk46493
CSCdk49143

When four VCs are sending data simultaneously and are configured on one port, the bandwidth is not distributed fairly.

Impact: If four VCs are configured for one line port and sending data simultaneously, the bandwidth for some of the VCs is not distributed fairly among each of the VCs. Users on some of those VCs may not get their provisioned bandwidth.

Workaround: There is no workaround. The network interface does not perform per-VC queuing.

CSCdk53830

The counter "Failed Trains due to nontimer enabled CPE" not visible while the system is in Direct Connect mode.

Impact: If the system is in Direct Connect mode, you do not know how many times a line port failed to train because the CPE gear is not timer enabled.

Workaround: None.

CSCdk53848

Life Line not preserved when POTS splitter card is removed.

Impact: When the POTS card is removed, phone service is lost.

Workaround: Do not remove the POTS card.

CSCdk55611

If you specify a bad TFTP Server IP Address from the Boot ROM Menu Screen, the system controller will fail the download and will not run.

Impact: The system controller will not load with the proper image if you specify a bad TFTP Server IP Address from the Boot ROM Menu Screen.

Workaround: The user must specify the proper TFTP Server IP Address during downloads.

CSCdk92817

CLI password command accepts illegal passwords. The command line interface accepts function keys as legal password characters.

Impact: In password command, enter "123<F1>" when prompted for new password and then "123" when prompted to Reenter password. You will receive an error message that "passwords don't match".

Workaround: Do not enter function keys for password characters.

CSCdm01442

PVC idle cell count incorrect.

Impact: The PVC idle cell count currently is a little off when determining if a subscriber is idle or not.

Workaround: Customer can add a 2 percent cell buffer when setting the PVC idle mark value.

CSCdm03741

Inaccurate time stamp given in event log as to the time that the network interface module was inserted.

Impact: Occurs very rarely after network interface power cycle.

Workaround: None.

CSCdm08281

A random set of modems fails to attempt to train after power cycle.

Impact: Occurs after power cycle of the system controller, or software download. Rate of occurrence is 1/4 of 1 percent.

Workaround: Lock/Unlock the offending modem port. Alternatively, the module may be removed and reinserted.

CSCdm21026

Reseating OC-3 network interface generates a buffer overflow msg in VR4W.

Impact: When a network interface is reseated in the chassis, a message is generated in the ViewRunner log indicating the following error:

Buffer overflow in the cell buffer on the subtend module

This occurs whenever a network interface is reseated. Even though the message refers to a subtend module, you do not need to be present for this message to appear.

Workaround: None required. This is a spurious error message that does not affect operations in any way.

CSCdm23668

FEC Redundancy bytes has no effect.

When a subscriber is configured for any of the FEC Redundancy bytes values under the DMT-2 modem parameters, there are no variation in the trained rate and error correction rate.

Impact: None.

Workaround: There is no workaround. This problem is due to a limitation with third-party hardware. There is currently no scheduled date from the vendor for resolution of the problem.

CSCdm25685

No support for G.dmt and G.lite.

Impact: G.lite or G.dmt cannot be configured for dual-port DMT-2 cards. This is true for all conditions.

Workaround: No workaround. G.lite and G.dmt are not supported in this release for dual-port DMT-2. They are scheduled to be part of a future release. This problem is due to a limitation with third-party hardware. There is currently no scheduled date from the vendor for resolution of the problem.

CSCdm36644

9000-9350 ft/-34 dBMHz, CPE cannot train.

Impact: Setting a subscriber to a PSD setting other than the default value of -40 dB may cause unpredictable results. In particular, a setting of -34 dB will cause the subscriber to continually retrain.

Workaround: Leave the subscriber PSD setting at the default of -40 dB. This problem is due to a limitation with third-party hardware. There is currently no scheduled date from the vendor for resolution of the problem.

CSCdm40771

Could not login to network interface debug mode after creating 1600 PVCs and 1.

Impact: Cannot login to network interface debug mode after creating 1600 PVCs and 1500 transit subscribers. Occurs after creating greater than 1600 subscribers and 1100 transit subscribers.

Workaround: None. Due to memory limitations, you cannot enter network interface debug mode after exceeding this number of subscribers and transit subscribers. The fix is scheduled to be incorporated in the next major release.

CSCdm41552

SDSL downstream traffic contention between odd and even ports.

When odd ports (1 and 3) and even ports (2 and 4) are used concurrently, there is traffic contention between the ports of the same pair downstream, for example, between 1 and 3 or between 2 and 4. One of the ports may experience significant packet loss downstream. There is no contention for upstream traffic.

Impact: The contention happens only for downstream traffic.

Workaround: Shape the downstream traffic rate to the trained rate on a per-PVC basis on the router that is directly terminating the PVC on the upstream side of the network interface. For example, on a Cisco 7200 router that has the PVC to a network interface, enter the IOS command "ubr rate" under the PVC, where the rate is the trained rate for the SDSL port in kilobits per second.

CSCdm41964

DMT-2 line card FE Corrected Blocks don't match CPE.

Impact: When corrected/uncorrected blocks are checked at the CO side then compared with similar statistics on the CPE side, the values may not necessarily match. Other statistics may also be out of sync. This can occur with any kind of connection.

Workaround: None. There are slight differences in the manner in which the firmware reports statistics to the CO and the CPE side. The discrepancies are not severe enough to impact accurate reporting of general functionality. This problem is due to a limitation with third-party hardware. There is currently no scheduled date from the vendor for resolution of the problem.

CSCdm43638

DMT-2 fails to meet T1.413 loop midCSA 6—cannot set margin of 3.

Impact: When running T1.413 MidCSA 6 loop, the required rate cannot be met. MidCSA 6 requires a margin setting of 3; however, there is no way to set the margin below 6. Although you can set the value below 6 in ViewRunner, the margin will remain at 6.

Workaround: None. This problem is due to a limitation with third-party hardware. There is currently no scheduled date from the vendor for resolution of the problem.

CSCdm46110

DS3 subtending bandwidth is less than 40.7 Mbps.

Impact: When a rate greater than 40.2 Mbps of traffic is sent through the DS3 subtend ports, traffic will be sent no faster than 40.2 Mbps. This occurs only when attempting to send traffic at a rate greater than 40.2 Mbps through the subtend ports.

Workaround: None. This change was needed to keep cells from being lost due to the inability of the subtend ports to handle traffic greater than 40.2 Mbps.

CSCdm52542

DMT Downstream file transfer performance overly impacted by upstream rate.

Impact: When the downstream rate is set much higher than the upstream rate—for example, 1544/96—the data transfer rates will likely not be as high as would be expected for downstream data transfers. This occurs when upstream rates are set very low relative to downstream rates, and particularly for file transfers that require acknowledgements, such as FTP.

Workaround: Do not set very low upstream rates, such as below 256 K, when using high downstream rates.

CSCdm59472

DMT cannot train at 128 K increment for upstream.

Impact: When a subscriber is configured for an upstream rate that is an increment of 128 K such as 128 K, 256 K, and so on, the trained rate will always be at least 32 K below the configured rate. This only occurs with upstream increments of 128 K.

Workaround: There is no workaround to obtain an increment of 128 K. If a higher rate is desired, setting the next higher rate will allow this. For example, to get greater than 128 K, provision for 160 K, which will result in a 160 K trained rate.

CSCdm69047

DMT Setting PSD -43 = -52; -46 = -40; -49 = -40.

Impact: Setting the PSD to -46 dB or -49 dB in ViewRunner results in the downstream PSD still being the default of -40 dB. This occurs only with DMT-2.

Workaround: None. The inability to set PSD lower than -43 dB is due to a limitation with third-party hardware. There is currently no scheduled date from the vendor for resolution of the problem. Cisco strongly recommends that the default PSD of -40 dB be used.

CSCdm69068

DMT with trellis enable, CB/UB go down, but intermittent high ES1 .

Impact: Trellis coding enabled for a subscriber causes the connection to show up with a high ratio of corrected/uncorrected blocks and excessive ES counts. This occurs when trellis coding is enabled at both the CO and CPE so that trellis is then active for the connection.

Workaround: Do not enable trellis for the subscriber. This problem is due to a limitation with third-party hardware. There is currently no scheduled date from the vendor for resolution of the problem.

CSCdm76074

DMT 16000, 32000 and 64000 interleave all equal maximum.

Impact: Setting interleave for DMT-2 line cards to 16000, 32000 or 64000 all results in the maximum interleave setting being used. This will show up on the CPE output as interleave = 64. This occurs whenever any of these interleave settings are utilized.

Workaround: None. This is the maximum interleave that currently can be obtained with DMT-2 in the Cisco 6130. This problem is due to a limitation with third-party hardware. There is currently no scheduled date from the vendor for resolution of the problem.

CSCdm77282

DMT-2 margins cannot be set lower than 6 dB.

Impact: Setting margin for DMT-2 lower than 6 does not change the actual setting, which will still be 6 dB. This occurs with any DMT-2 margin setting less than 6 dB.

Workaround: None. This problem is due to a limitation with third-party hardware. There is currently no scheduled date from the vendor for resolution of the problem.

CSCdm77285

Enabling DMT-2 Bit swapping has no effect.

Impact: This occurs under all circumstances whenever bit swapping is set.

Workaround: None. Bit swapping is not supported in the current release. This problem is due to a limitation with third-party hardware. There is currently no scheduled date from the vendor for resolution of the problem.

CSCdm81817

DMT-2 various mode, upstream rate combos cause high ES, CB.

Impact: Excessively high corrected/uncorrected block ratios and ES counts are seen when the following combinations are provisioned for a subscriber: overhead framing mode-2, 64 kbps upstream; or overhead framing mode-3, 96 kbps upstream.

The high error rates only occur with the overhead framing mode-2, 64 kbps upstream, or overhead framing mode-3, 96 kbps upstream combinations.

Workaround: Do not provision a subscriber with either of these combinations of overhead framing mode and upstream rate. This problem is due to a limitation with third-party hardware. There is currently no scheduled date from the vendor for resolution of the problem.

CSCdm87044

ATU-C generates IPC to SMB Unable to allocate buffer!

Impact: After training up 64 modems at 864/8032 and requesting "status x" from all 64 ATU-C channels (via serial ports), the following error occurs for all ATUCs:

2DMT2_0.1> IPCtoSMB: Unable to allocate buffer!

This problem will also occur if

  • All 64 CPEs are in operational mode.

  • The subscribers are all ready to train at 864/8032; 3) The subscribers are unlocked simultaneously using CommandRunner. As the Cisco 6100 begins training units, the buffer error will occur.

Workaround: None required for the status command via the serial port issue because this requires special connectors that are not available to customers. For the problem with issuing "unlock all" in CommandRunner, the workaround is to not unlock all of the line modules or subscribers at once. They should be unlocked in batches of less than 8 at a time.

CSCdp12216

Flexi CAP port 1 & 3, 2 & 4 pairing loss of packets.

Impact: In NI-1 systems, each card is allocated two 9.1 Mbps data streams by the network interface. When quad-port cards are used, one network interface data stream is shared by ports 1 and 3 and the other is shared by ports 2 and 4. This means that the aggregate downstream rate of two ports that are sharing a network interface data stream cannot exceed 9.1 Mbps without data loss in the network interface.

Workaround: None.

CSCdp27472

2xDMT module does not support the fast path option. It has been set up not to break but it is still using the interleaver. The vendors firmware does not support the fast path at this time. It has been reproduced when implemented by running the interleaved path with a depth of 0. This simulates the fast path.

Impact: There will be a slight delay. Less than running with an interleaver delay but more than running the fast path.

Workaround: None.

CSCdp37068

Flexi cards (both CAP & DMT) occasionally download their images twice before they can come up.

Impact: Very minimal. This does not cause any problems, other than taking twice the amount of time that it normally takes to download an image.

Workaround: None. Wait until the flexi card comes up after the second download.

CSCdp39437

Bit swapping for the flexi DMT ATU-C module is not supported in this release of the GlobeSpan firmware.

Impact: Selecting bit swapping from the subscriber option menu will have no effect.

Workaround: None.

CSCdp39444

Framing modes 0, 1, and 2 for the flexi DMT ATU-C module are not supported in this release of the GlobeSpan firmware.

Impact: User will not see the effect of selecting the framing mode 0, 1 and 2.

Workaround: Select mode 3 only.

CSCdp52726

SDSL overhead causes 16 K lower throughput.

Impact: When SDSL is utilized, measured rates will be 16 K lower than the trained line rate. This only occurs with SDSL.

Workaround: None. Because of the nature of SDSL, overhead causes the traffic rate to be 16 K lower than the trained line rate.

CSCdp53139

The flexi DMT ATU-C module does not support Fast Train in G.lite mode.

Impact: Fast retrain is not supported in the current GlobeSpan firmware. Selecting fast train from the subscriber options menu will have no effect.

Workaround: None.

CSCdp53238

Flexi DMT problems with 0 loop, 0 delay

Impact: Running on loops under 1.8 kft with trellis or Reed-Solomon disabled can lead to data loss due to CRC errors and to dropped links.

Workaround: To correct this behavior, enable trellis and Reed-Solomon at under 1.8 kft line lengths.

CSCdp67298

DMT: Intermittent CRC HEC, esp short loops

Impact: Intermittently, certain trains result in RS Corrected Bytes, CRC and HEC counters to rise. The problems arise at lengths between 0 to 1800 ft and 5500 to 6000 feet with trellis off and when trained greater than 7680 kbps down.

Workaround:

    1. Enabling trellis coding on the CO corrects this issue. The default setting for trellis is disabled in ViewRunner but is enabled on the 678.

    2. Lowering the provisioned rate for the subscriber to 7680/864 kbps or lower.

CSCdp74006

2xDMT2 won't train at 7680, 7744, 7808, 7872, 7936, and 8000. This is because the vendors firmware does not support the symbol rate (S) = 1/2. This is the symbol rate that is selected for these configurations. If the line is provisioned for a high bit rate and a high FEC redundancy byte count, then this can occur. The line will not train at the provisioned rate. It may be possible that the line will train higher than the provisioned rate.

Impact: There is not an impact while attempting to pass data. The only impact is that the line will not train at the provisioned downstream bit rate.

Workaround: None.

CSCdp74033

Wrong actual Upstream PSD Mask reported for dual-port DMT. The vendors firmware does not currently support remote reporting of the CPE PSD setting. The firmware simply reports a PSD setting of -82 dBMHz, which is the lowest possible value.

Impact: There is no impact on traffic. This simply means that the CO (61xx) cannot read the transmit PSD setting on the CPE device. This is simply a performance reporting problem.

Workaround: In most configurations, it may be possible to telnet to the CPE and use its CLI to view the PSD setting.

CSCdp78366

In the OC-3 network interface, if previously connected CPEs are powered off, the Tx and Rx cell counts as shown by ViewRunner or through the network interface keep incrementing.

Impact: The cell counts shown might not indicate that of the actual traffic.

Workaround: None.

CSCdp79172

TFTP failed after clearing NVRAM and Flash. Sometimes when the system controller is booting it displays an error message "TFTP: de_open failed for DEV_TFTP Error Code: 0x10060002". This message is displayed when the system controller does not get a response from the TFTP server (when there are problems in the network). However, the system controller would recover from the failure if the network becomes stable and the TFTP server is able to communicate with it.

Impact: Because the system controller recovers from the failure, the TFTP succeeds in the next attempt. The impact is a slight delay while booting.

Workaround: None.

CSCdp79941

Some STU-C modules lose packets during 12-hour traffic run.

Impact: This is an ongoing problem that is occurring in the current 2.4.x release. The data loss is minimal and should be recoverable. This is being investigated and will be fixed in the next release.

Workaround: None.

CSCdp79976

Some Cisco 677s dropped train with the dual-port DMT line card during traffic.

This has occurred occasionally on a Cisco 6100 loaded fully with 32 dual-port DMT-2 cards provisioned at 2560/864 kbps, some ports occasionally drop train when traffic is run for around 12 hours.

Impact: Because the ports that drop the train retrain and come up immediately, the impact is minimal.

Workaround: None. The problem has occurred only on a fully loaded Cisco 6100/6130 with 32 DMT-2 cards.

CSCdp81373

System controller is not up after pulling power off/on 6100 during TFTP upgrade. If power is switched off and the Ethernet connection is also pulled down when the system controller is doing a TFTP of images while upgrading, the system controller will not come up after the power is switched on.

Impact: None. This is a stress-test case and not a real-world scenario.

Workaround: System controller has to be rebooted from the system controller boot prompt.

CSCdp84935

Occasionally a flexi CAP ATU-C module port may drop train 1 to 2 seconds after it has successfully trained. It seems to always retrain to the same rates on the second try.

Impact: If the port drops train and then retrains, it could add 6 to 10 seconds to the total train time. The cause of this problem is still under investigation, so the solution/fix is still unknown.

Workaround: None.

CSCdp85772

Intermittently, two (out of 112) flexi CAP ATU-C module ports do not train at 1088 after the system controller is reset.

Impact: The flexi CAP ATU-C module trains at a lower rate than 1088.

Workaround: None.

CSCdp85795

Flexi line ports drop train during overnight traffic.

Impact: Since the ports will retrain to the correct rate again and the lost cells can be recovered with error handling, this is a low severity DDTS that will be investigated and fixed in the next release.

Workaround: Error handling should automatically recover any lost cells when the port retrains.

CSCdr17543

Flexi DMT does not pass Mid-CSA T1.413 CAT1 Loop.

Impact: MidCSA6 T1.413 Category 1 performance is not met by 0.7 dB, the DSL system vendor is currently working on improving its performance but it is well known that not a single vendor currently meets this specification. Subsequent releases of software will address this issue.

Workaround: None.

CSCdr19535

2xDMT2 Upstream rate of 32 does not pass data.

Impact: This is the lowest upstream bit rate available and as such should not impact most users who will train at much higher upstream rates. This will be fixed in a future release.

Workaround: Provision for a higher upstream bit rate.

CSCdr19781

2xDMT Actual margins less than provisioned for up and down.

Impact: It is a reporting problem, no operational impact.

Workaround: None.

CSCdr23589

When a Flexi DMT subscriber is provisioned with a short interleave delay (less than 8000 usec's) and a long line length (greater than ~10,000 ft), passing traffic will generate CRC errors, HEC errors and lost data in the downstream direction only. Upstream traffic works fine.

Impact: Errors in downstream traffic when interleave delay is less than 8000 usec and long line lengths (more than 10 k).

Workaround: Force the subscriber to train at a lower downstream rate.

Note   For more information on this DDTS, please contact your Cisco marketing representative.

CSCdr25430

The CLI command "ds vc x y" reports wrong for 2nd STM port transit subscriber.

Impact: The queries on vpi values for trsub connected to subtend port 2 fail.

Workaround:

    1. At NI user interface type "ds all" to get ConnTag(s) of all active connections.

    2. Query on the ConnTag gives the necessary info.

CSCdr28130

In DOH configuration, if the CPE signature of the subscriber is set to a high value, the CPE Rejects counter on the subscriber would not get incremented whenever the CPE tries to train. A major alarm would be asserted against the line port to which the subscriber is connected.

Impact: Impact of the bug is low. Only the counter that can be viewed by the user will not be incremented.

Workaround: None.

CSCdr31073

4xSDSL loses packets when at 18K length and 1168 Kbps line rate.

Impact: This happens only at very long lengths (18k) 24AWG wire.

Workaround: Try to train at relatively lower length or lower line rate.

CSCdr35250

Some commands from NI cut-through redirect output to NI serial session.

Impact: The response of these few commands is not displayed on the console of the cut-through session. Instead, the response is displayed on any serial sessions open to the NI at that instance.

Workaround: None.

CSCdr35295

Cell leakage on trunk port when DS3 internal loopback enabled.

Impact: Cell loss only when in loopback testing mode.

Workaround: None.

CSCdr35687

Between one and four frames are lost (per minute) downstream on a G.lite port when the downstream margin is set between 0 and 4 dB when the line length is 15000 feet of 26 AWG. There were no losses at 2 k or 9350 feet.

Impact: Loss of frames in downstream G.lite, at lower margins (less than 4) and 15 k plus line lengths.

Workaround: Use higher margin than 4 dB.

CSCdr43807

Wrong alarm asserted when inserting 2xDMT preprovisioned for Flexi DMT.

Impact: "No image exists for the module type present in the slot." This alarm is being reported instead of "A module was inserted in the slot that did not match the type that was preprovisioned for the slot."

Workaround: None.

CSCne01131

During a network interface reset, active OC-3 cell flow may cause network interface alarm and network interface shutdown on power-up.

Impact: If the fiber is currently plugged in and active, during install or reset of the system, then the network interface may shut down. The following alarm in ViewRunner is provided to alert the user of this problem: "ATM SWITCH POLLING RATE IS INADEQUATE, CELLS DROPPED."

Workaround: Disconnect fiber and restart network interface.

CSCne01901

Infrequently, in a single LIM chassis system, if you replace a LIM controller, this causes ViewRunner to display two LIM chassis.

Impact: Displays a LIM chassis, which does not exist.

Workaround: Delete second LIM chassis.

CSCne01912
CSCne01913

DS3 subtending port does not block data flow upon port or module lock. Unimplemented feature at this time.

Impact: Cannot block data by unlocking subtend port.

Workaround: To block the data, pull out the DS3 cable.

CSCne02176

When locked, Cisco 6100 modules still respond with alarms when pulled from chassis.

Impact: No system impact; unimplemented feature.

Workaround: None.

CSCne02362
CSCne02112

System control IP information becomes corrupted after save or after BOOTP is completed.

Impact: Only an installation impact when you use the BOOTP capability.

Workaround: Reenter the system controller IP address in the boot menu.

1ES = errored second

Resolved Caveats

The caveats listed in Table 10 are resolved in Release 3.1.0.


Table 10: Resolved Caveats in Release 3.1.0
DDTS ID Description

CSCdm26031

CM is allocating temporary memory from the long term region.

CSCdm26032

Trace logging is using long term memory for temporary storage.

CSCdp36370

Flexi (CAP or DMT) module retrains on all four ports simultaneously.

CSCdp57414

2xCAP and flexi (CAP) cannot train upstream @ 1088 with margin = 6/6.

CSCdp70154

Flexi has intermittent single-port retrains (CAP or DMT).

CSCdp79960

All 4 ports dropped train on STU-C module while there is no traffic.

CSCdp80537

Minor alarms appear when the SDSL boards are in normal condition after changing the right chassis half from CAP/DMT-2 to SDSL after upgrading to Release 3.0.

CSCdp84274

Actual margins less than provisioned margins (flexi CAP and 2xCAP).

CSCdp86453

Dual-port CAP & flexi CAP fail to train to a valid rate if provision invalid.

CSCdp87713

Dual-port CAP line card showing actual downstream transmit PSD as -38 when provisioned for -49. The actual transmit PSD should be less than or equal to the provisioned transmit PSD mask.

CSCdp88314

Default Q priority in subscriber PVC is voice instead of data.

While creating a PVC for a subscriber without passing value for lrSubscrPvcQPriority, the default value assigned by the node software is QP1 instead of QP3 as mentioned in the MIB. This is seen only while using MIB browsers other than ViewRunner.

CSCdp88713

Flexi DMT module trains to lower rate than provisioned when the interleaved delay is set to 250 microseconds.

Configuring the interleave delay to be 250 microseconds decreases the maximum achievable upstream rate to 736 to 768 kbps (depending on other configuration options).

CSCdp91694

Alarm severity levels for certain events are incorrect.

The following alarms have incorrect severity levels:

  • DS3:102: PLCP loss of frame error detected—Minor (should be Critical)

  • OC3:60: Loss of frame condition—Info (should be Critical)

  • OC3:48: Loss of cell delineation—Info (should be Critical)

  • OC3:55: Auto protection switch byte is corrupted 3 of 12 bytes—Minor (should be Info)

  • OC3:54: Auto protection switch—Critical (should be Info)

CSCdp94778

Flexi and 678 retrain improperly with G.96.

CSCdp99119

Flexi does not pass T1.413 test loops.

CSCdr05558

On a DOH system, the MIB variable lrPoolTotalMinutes always equals zero.

CSCdr06376

DOH BlockedMinutes counter never increments.

CSCdr26178

4xSDSL line card does not pass or stops passing data.

CSCdr33953

Flexi DMT reports wrong margin when connected to Alcetel-based CPE.

CSCdr34506

Flexi DMT not using symbols/code word parameters from system controller.

Related Documentation

The following sections list the CO and CPE publications that relate to the Cisco DSL product family.

CO Publications

A complete list of all released Cisco 6100 Series system with NI-1 related documentation is available on the World Wide Web at http://www.cisco.com/univercd/cc/td/doc/product/dsl_prod/c6100/index.htm.

The following ViewRunner management software is used to provision and manage the Cisco 6100 Series system with NI-1. A complete list of all released ViewRunner documentation is available on the Word Wide Web.

CPE Publications

The Cisco CPE, also known as the Cisco 600 Series, is part of the Cisco end-to-end DSL product family. CPE comprises modems and routers at the customer site primarily used by home office and corporate LAN personnel. Most CPE uses the Cisco Broadband Operating System (CBOS) as its operating system. CBOS provides a comprehensive command set and web interface that allow you to configure your Cisco CPE modem or router.

A complete list of all released Cisco 600 Series documentation is available on the World Wide Web at http://www.cisco.com/univercd/cc/td/doc/product/dsl_prod/c600s/index.htm.

Obtaining Documentation

The following sections provide sources for obtaining documentation from Cisco Systems.

World Wide Web

You can access the most current Cisco documentation on the World Wide Web at http://www.cisco.com, http://www-china.cisco.com, or http://www-europe.cisco.com.

Documentation CD-ROM

Cisco documentation and additional literature are available in a CD-ROM package, which ships with your product. The Documentation CD-ROM is updated monthly. Therefore, it is probably more current than printed documentation. The CD-ROM package is available as a single unit or as an annual subscription.

Ordering Documentation

Registered CCO users can order the Documentation CD-ROM and other Cisco Product documentation through our online Subscription Services at http://www.cisco.com/cgi-bin/subcat/kaojump.cgi.

Nonregistered CCO users can order documentation through a local account representative by calling Cisco's corporate headquarters (California, USA) at 408 526-4000 or, in North America, call 800 553-NETS (6387).

Obtaining Technical Assistance

Cisco provides Cisco Connection Online (CCO) as a starting point for all technical assistance. Warranty or maintenance contract customers can use the Technical Assistance Center. All customers can submit technical feedback on Cisco documentation using the web, e-mail, a self-addressed stamped response card included in many printed docs, or by sending mail to Cisco.

Cisco Connection Online

Cisco continues to revolutionize how business is done on the Internet. Cisco Connection Online is the foundation of a suite of interactive, networked services that provides immediate, open access to Cisco information and resources at anytime, from anywhere in the world. This highly integrated Internet application is a powerful, easy-to-use tool for doing business with Cisco.

CCO's broad range of features and services helps customers and partners to streamline business processes and improve productivity. Through CCO, you will find information about Cisco and our networking solutions, services, and programs. In addition, you can resolve technical issues with online support services, download and test software packages, and order Cisco learning materials and merchandise. Valuable online skill assessment, training, and certification programs are also available.

Customers and partners can self-register on CCO to obtain additional personalized information and services. Registered users may order products, check on the status of an order and view benefits specific to their relationships with Cisco.

You can access CCO in the following ways:

You can e-mail questions about using CCO to cco-team@cisco.com.

Technical Assistance Center

The Cisco Technical Assistance Center (TAC) is available to warranty or maintenance contract customers who need technical assistance with a Cisco product that is under warranty or covered by a maintenance contract.

To display the TAC web site that includes links to technical support information and software upgrades and for requesting TAC support, use www.cisco.com/techsupport.

To contact by e-mail, use one of the following:

Language E-mail Address

English

tac@cisco.com

Hanzi (Chinese)

chinese-tac@cisco.com

Kanji (Japanese)

japan-tac@cisco.com

Hangul (Korean)

korea-tac@cisco.com

Spanish

tac@cisco.com

Thai

thai-tac@cisco.com

In North America, TAC can be reached at 800 553-2447 or 408 526-7209. For other telephone numbers and TAC e-mail addresses worldwide, consult the following web site: http://www.cisco.com/warp/public/687/Directory/DirTAC.shtml.

Documentation Feedback

If you are reading Cisco product documentation on the World Wide Web, you can submit technical comments electronically. Click Feedback in the toolbar and select Documentation. After you complete the form, click Submit to send it to Cisco.

You can e-mail your comments to bug-doc@cisco.com.

To submit your comments by mail, for your convenience many documents contain a response card behind the front cover. Otherwise, you can mail your comments to the following address:

Cisco Systems, Inc.
Document Resource Connection
170 West Tasman Drive
San Jose, CA 95134-9883

We appreciate and value your comments.

This document is to be used in conjunction with the Related Documentation publication.

Access Registrar, AccessPath, Any to Any, AtmDirector, Browse with Me, CCDA, CCDE, CCDP, CCIE, CCNA, CCNP, CCSI, CD-PAC, the Cisco logo, Cisco Certified Internetwork Expert logo, CiscoLink, the Cisco Management Connection logo, the Cisco NetWorks logo, the Cisco Powered Network logo, Cisco Systems Capital, the Cisco Systems Capital logo, Cisco Systems Networking Academy, the Cisco Systems Networking Academy logo, the Cisco Technologies logo, ConnectWay, Fast Step, FireRunner, Follow Me Browsing, FormShare, GigaStack, IGX, Intelligence in the Optical Core, Internet Quotient, IP/VC, Kernel Proxy, MGX, Natural Network Viewer, NetSonar, Network Registrar, the Networkers logo, Packet, PIX, Point and Click Internetworking, Policy Builder, Precept, RateMUX, ScriptShare, Secure Script, ServiceWay, Shop with Me, SlideCast, SMARTnet, SVX, The Cell, TrafficDirector, TransPath, ViewRunner, Virtual Loop Carrier System, Virtual Voice Line, VlanDirector, Voice LAN, Wavelength Router, Workgroup Director, and Workgroup Stack are trademarks; Changing the Way We Work, Live, Play, and Learn, Empowering the Internet Generation, The Internet Economy, and The New Internet Economy are service marks; and Aironet, ASIST, BPX, Catalyst, Cisco, Cisco IOS, the Cisco IOS logo, Cisco Systems, the Cisco Systems logo, the Cisco Systems Cisco Press logo, Enterprise/Solver, EtherChannel, EtherSwitch, FastHub, FastLink, FastPAD, FastSwitch, GeoTel, IOS, IP/TV, IPX, LightStream, LightSwitch, MICA, NetRanger, Post-Routing, Pre-Routing, Registrar, StrataView Plus, Stratm, TeleRouter, and VCO are registered trademarks of Cisco Systems, Inc. or its affiliates in the U.S. and certain other countries. All other trademarks mentioned in this document are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any of its resellers. (0004R)

Copyright © 2000, Cisco Systems, Inc.
All rights reserved.


hometocprevnextglossaryfeedbacksearchhelp
Posted: Mon Sep 16 16:39:39 PDT 2002
All contents are Copyright © 1992--2002 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.