Table Of Contents
Guide to Supported Hardware for Cisco 7600 Series Routers with Cisco IOS Release 12.2SR
Distributed and Centralized Forwarding Cards
10-Gigabit Ethernet Switching Modules
Gigabit Ethernet Switching Modules
Small Form-Factor Pluggable Modules (SFPs)
10-Gigabit Ethernet Transceiver Modules
Gigabit Interface Converters (GBICs)
Power over Ethernet Daughtercards
10/100/1000 Ethernet Switching Modules
Fast Ethernet Switching Modules
Ethernet/Fast Ethernet (10/100) Switching Modules
Optical Services Modules (OSMs)
SPA Interface Processors (SIPs)
Circuit Emulation over Packet (CEoP) SPAs
Enhanced FlexWAN Module Port Adapters
Ethernet Services 20G Line Cards
Unsupported Supervisor Engines
Unsupported Policy Feature Cards and Distributed Forwarding Cards
Cisco Product Security Overview
Reporting Security Problems in Cisco Products
Product Alerts and Field Notices
Obtaining Technical Assistance
Definitions of Service Request Severity
Obtaining Additional Publications and Information
Guide to Supported Hardware for Cisco 7600 Series Routers with Cisco IOS Release 12.2SR
This publication lists the supported hardware for Cisco 7600 series routers with Cisco IOS Release 12.2SR.
Use this publication with the Release Notes for Cisco IOS Release 12.2SRA on the Cisco 7600 Series Routers.
Contents
This publication contains these sections:
•
Cisco Product Security Overview
•
Product Alerts and Field Notices
•
Obtaining Technical Assistance
•
Obtaining Additional Publications and Information
Document Revision History
Supported Hardware
These sections describe the hardware supported in Cisco IOS Release 12.2SR:
•
Distributed and Centralized Forwarding Cards
•
XENPAKs
•
Small Form-Factor Pluggable Modules (SFPs)
•
10-Gigabit Ethernet Transceiver Modules
•
Gigabit Interface Converters (GBICs)
•
Power over Ethernet Daughtercards
•
10/100/1000 Ethernet Switching Modules
•
Fast Ethernet Switching Modules
•
Ethernet/Fast Ethernet (10/100) Switching Modules
•
Optical Services Modules (OSMs)
•
SPA Interface Processors (SIPs)
•
Enhanced FlexWAN Module Port Adapters
•
Chassis
Note
•
Use the values in the "Power Required" column to determine the exact power requirements for your configuration to ensure that you are within the power budget.
•
Daughtercard power is shown separately.
•
Enter the show power command to display current system power usage.
Supervisor Engines
•
Route Switching Processor 720
Supervisor Engine 720
•
Supervisor Engine 720 Common Features
•
Supervisor Engine 720 with PFC3BXL
•
Supervisor Engine 720 with PFC3B
Supervisor Engine 720 Common Features
•
Integrated 720-Gbps Switch Fabric
•
64-MB bootflash device
•
2 CompactFlash Type II slots (disk0 and disk1)
Note
Some Supervisor Engine 720 Release 12.2SR images are larger than the bootflash device and must be stored on a CompactFlash card.
•
Two Ethernet uplink ports:
–
1-MB packet buffer per port
–
Port 1— Gigabit Ethernet SFP
–
Port 2—Configurable as Gigabit Ethernet SFP or 10/100/1000 Mbps RJ-45
•
QoS port architecture (Rx/Tx): 1p1q4t/1p2q2t
•
Port grouping:
–
Number of ports: 2
–
Number of port groups: 1
–
Port ranges per port group: 1-2
•
Supervisor Engine 720 requires a high-capacity fan tray (see the "Fan Trays" section)
Supervisor Engine 720 with PFC3BXL
Product ID
(append "=" for spares) Power
Required Product Description Minimum Software Version WS-SUP720-3BXL7.82 A@42 V
Supervisor Engine 720 with PFC3BXL:
•
1-GB DRAM
•
Policy Feature Card 3BXL (PFC3BXL); see the "RSP720-3C-10GE" section
•
Multilayer Switch Feature Card 3 (MSFC3):
–
1-GB DRAM
–
64-MB bootflash
12.2(33)SRA
Note
There are no memory upgrade options for WS-SUP720-3BXL.
Supervisor Engine 720 with PFC3B
Product ID
(append "=" for spares) Power
Required Product Description Minimum Software Version WS-SUP720-3B7.50 A@42 V
Supervisor Engine 720 with PFC3B:
•
512-MB DRAM
•
Policy Feature Card 3B (PFC3B); see the "RSP720-3C-10GE" section
•
Multilayer Switch Feature Card 3 (MSFC3):
–
512-MB DRAM
–
64-MB bootflash
12.2(33)SRA
Note
![]()
•
There are no memory-only upgrade options for WS-SUP720-3B.
•
Use WS-F6K-PFC3BXL= to upgrade a WS-SUP720-3B with a PFC3BXL. WS-F6K-PFC3BXL= includes 1 GB memory upgrades for the Supervisor Engine 720 and the MSFC3. Refer to this publication for more information:
http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/cfgnotes/78_16220.htm
Supervisor Engine 32
Note
Supervisor Engine 32 does not support this hardware:
•
WS-SUP720-3B
•
WS-F6K-PFC3BXL—Policy Feature Card 3BXL (PFC3BXL)
•
Distributed Forwarding Cards (DFCs) (installed DFCs do not power up with a Supervisor Engine 32)
•
Switch Fabric Modules
•
These switching modules:
–
WS-X6704-10GE—4-port 10-Gigabit Ethernet XENPAK
–
WS-X6748-SFP—48-port Gigabit Ethernet SFP
–
WS-X6724-SFP—24-port Gigabit Ethernet SFP
–
WS-X6816-GBIC—16-port Gigabit Ethernet GBIC
–
WS-X6748-GE-TX—48-port 10/100/1000 RJ-45
•
7600-SIP-600—SPA Interface Processor-600
•
Optical Services Modules (OSMs)
•
CISCO7603—3-slot chassis
•
These service modules:
–
WS-SVC-AON-1-K9—Application-Oriented Networking Module
–
WS-SVC-AGM-1-K9—Anomaly Guard Module
–
WS-SVC-ADM-1-K9—Traffic Anomaly Detector Module
–
WS-SVC-MWAM-1—Multi-Processor WAN Application Module
•
Supervisor Engine 32 does not support these software features and commands:
–
Protocol independent multicast (PIM) snooping designated-router flooding configurability
–
NetFlow version 9
–
Egress multicast replication
–
Multicast replication mode detection
–
All fabric configuration commands
Product ID
(append "=" for spares) Power
Required Product Description Minimum Software Version WS-SUP32-10GE-3B2.39 A@42 V
Supervisor Engine 32:
•
One 10/100/1000 Mbps RJ-45 port
•
WS-SUP32-10GE—two Gigabit Ethernet ports (requires XENPAKs)
•
WS-SUP32-GE—eight Gigabit Ethernet SFP ports (requires Gigabit Ethernet SFPs)
•
512-MB DRAM
•
256-MB bootflash
•
Policy Feature Card 3B (PFC3B); see the "RSP720-3C-10GE" section
•
Multilayer Switch Feature Card 2A (MSFC2A):
–
512-MB DRAM
–
64-MB bootflash
12.2(33)SRA
WS-SUP32-GE-3B1.89 A@42 V
Note
See this publication for Supervisor Engine 32 hardware information:
http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/6000hw/supe_gd/index.htm
Route Switching Processor 720
RSP 720 Common Features
•
Two Gigabit Ethernet uplink ports: port 1 supports a 1-Gbps small form pluggable (SFP) module; port 2 is configurable with either a 1-Gbps SFP module or a 10/100/1000-Mbps RJ-45
•
Integrated 720-Gbps switch fabric
•
Two CompactFlash Type II slots (on front panel) and 2-GB internal CompactFlash (1 GB each for RP and SP)
•
Requires larger power supplies and a high-speed fan tray
•
QoS port architecture (Rx/Tx) is 1p1q4t/1p2q2t
RSP720-3C-GE
RSP720-3CXL-GE
RSP720-3C-10GE
RSP720-3CXL-10GE
Policy Feature Cards
•
Policy Feature Card Guidelines and Restrictions
•
Distributed and Centralized Forwarding Cards
Policy Feature Card Guidelines and Restrictions
•
The PFC3 supports a theoretical maximum of 64,000 MAC addresses (32,000 MAC addresses recommended maximum).
•
You cannot use one type of PFC3 (PFC3BXL or PFC3B) on one supervisor engine and a different type on the other supervisor engine for redundancy. You must use identical policy feature cards for redundancy.
•
Enter the show platform hardware pfc mode command to display the PFC3 mode.
•
Enter the show platform earl-mode command to display the PFC3 mode.
•
PFC3B—These restrictions apply to a configuration with a PFC3B and these DFCs:
–
PFC3B and DFC3B—No restrictions.
–
PFC3B and DFC3BXL—The PFC3B restricts DFC3BXL functionality: after a reload with a DFC3BXL-equipped module installed, the DFC3BXL functions as a DFC3B.
•
PFC3BXL—These restrictions apply to a configuration with a PFC3BXL and these DFCs:
–
PFC3BXL and DFC3B—PFC3BXL functionality is restricted by the DFC3B: after a reload with a DFC3B-equipped module installed (whether powered up or down), the PFC3BXL functions as a PFC3B.
–
PFC3BXL and DFC3BXL—No restrictions.
•
The features that require the PFC3BXL or PFC3B are not supported in PFC3A mode (see the Release Notes for Cisco IOS Release 12.2SR on the Cisco 7600 Series Routers).
•
To use DFC3B-equipped switching modules with a PFC3BXL, the DFC3B-equipped switching modules must be installed at bootup.
Policy Feature Card 3BXL
Product ID
(append "=" for spares) Power
Required Product Description Minimum Software Version WS-F6K-PFC3BXL2.57 A@42 V
Policy Feature Card 3BXL (PFC3BXL)
Supported only with Supervisor Engine 720
12.2(33)SRA
Note
![]()
•
There are no memory upgrade options for WS-F6K-PFC3BXL.
•
Use WS-F6K-PFC3BXL= to upgrade a WS-SUP720 or WS-SUP720-3B with a PFC3BXL. WS-F6K-PFC3BXL= includes 1 GB memory upgrades for the Supervisor Engine 720 and the MSFC3. Refer to this publication for more information:
http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/cfgnotes/78_16220.htm
Policy Feature Card 3B
Product ID
(append "=" for spares) Power
Required Product Description Minimum Software Version WS-F6K-PFC3B2.25 A@42 V
Policy Feature Card 3B (PFC3B)
With Supervisor Engine 720
12.2(33)SRA
With Supervisor Engine 32
12.2(33)SRA
Note
![]()
•
There are no memory upgrade options for WS-F6K-PFC3B.
•
Use WS-F6K-PFC3BXL= to upgrade a WS-SUP720-3B with a PFC3BXL. WS-F6K-PFC3BXL= includes 1 GB memory upgrades for the Supervisor Engine 720 and the MSFC3. Refer to this publication for more information:
http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/cfgnotes/78_16220.htm
Policy Feature Card 3C
Policy Feature Card 3CXL
Distributed and Centralized Forwarding Cards
•
Centralized Forwarding Card (WS-X6700-CFC)
•
Distributed Forwarding Card 3BXL
•
Distributed Forwarding Card 3B
•
Distributed Forwarding Card 3CXL
•
Distributed Forwarding Card 3C
Note
See the "Route Switching Processor 720" section for Policy Feature Cards (PFC) and Distributed Forwarding Card (DFC) restrictions.
Centralized Forwarding Card (WS-X6700-CFC)
Distributed Forwarding Card 3BXL
WS-F6700-DFC3BXL
Product ID
(append "=" for spares) Power
Required Product Description Minimum Software Version WS-F6700-DFC3BXL3.30 A@42 V
Distributed Forwarding Card 3BXL (DFC3BXL) for use on CEF720 modules
Supported only with Supervisor Engine 720
12.2(33)SRA
Note
![]()
•
WS-F6700-DFC3BXL uses memory that is installed on the switching module.
•
Refer to this publication for information about WS-F6700-DFC3BXL upgrades:
http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/cfgnotes/78_15893.htm
WS-F6K-DFC3BXL
Product ID
(append "=" for spares) Power
Required Product Description Minimum Software Version WS-F6K-DFC3BXL1.47 A@42 V
Distributed Forwarding Card 3BXL (DFC3BXL) for use on dCEF256 and CEF256 modules
Supported only with Supervisor Engine 720
12.2(33)SRA
Note
![]()
•
Refer to this publication for information about WS-F6K-DFC3BXL memory upgrades:
http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/cfgnotes/78_12409.htm
•
Supervisor Engine 720 supports a WS-F6K-DFC3BXL on these WS-X6516-GBIC switching module hardware revisions:
–
Lower than 5.0
–
5.5 and higher
•
Supervisor Engine 720 does not support a DFC3 on WS-X6516-GBIC switching module hardware revisions 5.0 through 5.4. With a Supervisor Engine 720 and with a DFC3 installed, WS-X6516-GBIC switching module hardware revisions 5.0 through 5.4 do not power up.
•
With a Supervisor Engine 720 but without a DFC3, WS-X6516-GBIC switching module hardware revisions 5.0 through 5.4 operate in bus mode.
•
Refer to external field notice 24494 for more information about Supervisor Engine 720 and a DFC3 on WS-X6516-GBIC switching modules:
Distributed Forwarding Card 3B
WS-F6700-DFC3B
Product ID
(append "=" for spares) Power
Required Product Description Minimum Software Version WS-F6700-DFC3B3.00 A@42 V
Distributed Forwarding Card 3B (DFC3B) for use on CEF720 modules
Supported only with Supervisor Engine 720
12.2(33)SRA
Note
![]()
•
WS-F6700-DFC3B uses memory that is installed on the switching module.
•
Refer to this publication for information about WS-F6700-DFC3B upgrades:
http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/cfgnotes/78_15893.htm
WS-F6K-DFC3B
Product ID
(append "=" for spares) Power
Required Product Description Minimum Software Version WS-F6K-DFC3B1.67 A@42 V
Distributed Forwarding Card 3B (DFC3B) for use on dCEF256 and CEF256 modules
Supported only with Supervisor Engine 720
12.2(33)SRA
Note
![]()
•
Refer to this publication for information about WS-F6K-DFC3B memory upgrades:
http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/cfgnotes/78_12409.htm
•
Supervisor Engine 720 supports a WS-F6K-DFC3B on these WS-X6516-GBIC switching module hardware revisions:
–
Lower than 5.0
–
5.5 and higher
•
Supervisor Engine 720 does not support a DFC3 on WS-X6516-GBIC switching module hardware revisions 5.0 through 5.4. With a Supervisor Engine 720 and with a DFC3 installed, WS-X6516-GBIC switching module hardware revisions 5.0 through 5.4 do not power up.
•
With a Supervisor Engine 720 but without a DFC3, WS-X6516-GBIC switching module hardware revisions 5.0 through 5.4 operate in bus mode.
•
Refer to external field notice 24494 for more information about Supervisor Engine 720 and a DFC3 on WS-X6516-GBIC switching modules:
Distributed Forwarding Card 3CXL
Distributed Forwarding Card 3C
10-Gigabit Ethernet Switching Modules
Product ID
(append "=" for spares) Power
Required Product Description Minimum Software Version WS-X6704-10GE6.28 A@42 V
4-port 10-Gigabit Ethernet XENPAK
•
CEF720 with WS-X6700-CFC (adds 0.75 A@42 V)
•
dCEF720 with WS-F6700-DFC3BXL (adds 3.30 A@42 V)
•
dCEF720 with WS-F6700-DFC3B (adds 3.00 A@42 V)
•
Supports egress multicast replication
•
QoS port architecture (Rx/Tx):
–
With DFC3: 8q8t/1p7q8t
–
With CFC: 1q8t/1p7q8t
•
Number of ports: 4
Number of port groups: 4
Port ranges per port group: 1 port in each groupSupported only with Supervisor Engine 720
12.2(33)SRA
Note
![]()
•
WS-X6704-10GE requires one of the following:
–
WS-F6700-DFC3BXL (3.30 A@42 V)
–
WS-F6700-DFC3B (3.00 A@42 V)
–
WS-X6700-CFC (0.75 A@42 V)
•
WS-X6704-10GE ships with WS-X6700-CFC installed unless ordered with WS-F6700-DFC3BXL or WS-F6700-DFC3B.
•
WS-X6704-10GE is supported in the WS-C6503-E chassis.
•
WS-X6704-10GE is not supported in the WS-C6503 and CISCO7603 chassis.
•
In a 13-slot chassis, WS-X6704-10GE is supported only in slots 9 through 13 and does not power up in other slots.
•
On WS-X6704-10GE ports, Spanning Tree Protocol (STP) bridge protocol data units (BPDUs) are not exempt from Traffic Storm Control suppression. Do not configure Traffic Storm Control on STP-protected WS-X6704-10GE ports that interconnect network devices.
WS-X6502-10GE3.30 A@42 V
1-port 10-Gigabit Ethernet
•
With Supervisor Engine 720:
–
dCEF256 with WS-F6K-DFC3BXL (adds 1.47 A@42 V)
–
dCEF256 with WS-F6K-DFC3B (adds 1.67 A@42 V)
•
QoS port architecture (Rx/Tx): 1p1q8t/1p2q1t
•
Number of ports: 1
Number of port groups: 1
Port ranges per port group: 1 port in 1 group
With Supervisor Engine 720
12.2(33)SRA
With Supervisor Engine 32
12.2(33)SRA
Note
WS-X6502-10GE does not support Inter-Switch Link (ISL) encapsulation.
Optical Interface Module (OIM) for WS-X6502-10GE WS-G648810GBASE-LR serial 1310 nm long-reach OIM
12.2(33)SRA
WS-G648310GBASE-ER serial 1550 nm extended-reach OIM
12.2(33)SRA
Product ID
(append "=" for spares) Power
Required Product Description Minimum Software Version10.58A @42 V
8-port 10-Gigabit Ethernet X2module
•
dCEF720
•
Supports egress multicast replication
•
QoS port architecture (Rx/Tx): 8q4t/1p7q4t
•
Dual switch-fabric connections
Fabric Channel #1: Ports 2, 3, 6, 8
Fabric Channel #2: Ports 1, 4, 5, 7•
Number of ports: 8
Number of port groups: 8
Port ranges per port group: 1 port in each group11.28A @ 42V
Supported only with Supervisor Engine 720, Route Switch Processor 720, and RSP720-10GE.
12.2(33)SRC
X2 Modules Supported in Gigabit Ethernet SPAs
X2-10GB-SR
12.2(33)SRC
X2-10GB-CX4
12.2(33)SRC
X2-10GB-LX4
12.2(33)SRC
X2-10GB-ER
12.2(33)SRC
X2-10GB-LR
12.2(33)SRC
Note
![]()
•
To configure WS-X6708-10GE port oversubscription, refer to the hw-module oversubscription command in the command reference at this URL:
http://www.cisco.com/en/US/products/ps6922/prod_command_reference_list.html
•
Installation of a WS-X6708-10GE switching module in a chassis other than the following prevents operation at levels that are fully NEBS-compliant:
–
WS-C6509-NEB-A with dual fan tray
–
CISCO7609 with dual fan tray
•
WS-X6708-10G-3C and WS-X6708-10G-3CXL are the orderable product IDs.
•
The front panel is labeled WS-X6708-10GE.
•
Cisco IOS software commands display WS-X6708-10GE with either WS-F6700-DFC3C or WS-F6700-DFC3CXL.
•
WS-X6708-10GE ports do not support VACL capture. (CSCsb59015)
•
WS-X6708-10GE is not supported in the WS-C6503 and CISCO7603 chassis.
•
In a 13-slot chassis, WS-X6708-10GE is supported only in slots 9 through 13 and does not power up in other slots.
•
On WS-X6708-10GE ports, STP BPDUs are not exempt from Traffic Storm Control suppression. Do not configure Traffic Storm Control on STP-protected WS-X6708-10GE ports that interconnect network devices.
XENPAKs
X2 Modules
Gigabit Ethernet Switching Modules
Product ID
(append "=" for spares) Power
Required Product Description Minimum Software Version WS-X6748-SFP5.32 A@42 V
48-port Gigabit Ethernet SFP
•
CEF720 with WS-X6700-CFC (adds 0.75 A@42 V)
•
dCEF720 with WS-F6700-DFC3BXL (adds 3.30 A@42 V)
•
dCEF720 with WS-F6700-DFC3B (adds 3.00 A@42 V)
•
Supports egress multicast replication
•
QoS architecture:
–
With DFC3: 2q8t/1p3q8t
–
With CFC: 1q8t/1p3q8t
•
Number of ports: 48
Number of port groups: 4
Port ranges per port group:
1, 3, 5, 7, 9, 11, 13, 15, 17, 19, 21, 23
2, 4, 6, 8, 10, 12, 14, 16, 18, 20, 22, 24
25, 27, 29, 31, 33, 35, 37, 39, 41, 43, 45, 47
26, 28, 30, 32, 34, 36, 38, 40, 42, 44, 46, 48Supported only with Supervisor Engine 720
12.2(33)SRA
Note
![]()
•
WS-X6748-SFP requires one of the following:
–
WS-F6700-DFC3BXL (3.30 A@42 V)
–
WS-F6700-DFC3B (3.00 A@42 V)
–
WS-X6700-CFC (0.75 A@42 V)
•
WS-X6748-SFP ships with WS-X6700-CFC installed unless ordered with WS-F6700-DFC3BXL or WS-F6700-DFC3B.
•
WS-X6748-SFP is supported in the WS-C6503-E chassis.
•
WS-X6748-SFP is not supported in the WS-C6503 and CISCO7603 chassis.
•
In a 13-slot chassis, WS-X6748-SFP is supported only in slots 9 through 13 and does not power up in other slots.
•
On WS-X6748-SFP ports, STP BPDUs are not exempt from Traffic Storm Control suppression. Do not configure Traffic Storm Control on STP-protected WS-X6748-SFP ports that interconnect network devices.
•
See the "Small Form-Factor Pluggable Modules (SFPs)" section.
WS-X6724-SFP2.23 A@42 V
24-port Gigabit Ethernet SFP
•
CEF720 with WS-X6700-CFC (adds 0.75 A@42 V)
•
dCEF720 with WS-F6700-DFC3BXL (adds 3.30 A@42 V)
•
dCEF720 with WS-F6700-DFC3B (adds 3.00 A@42 V)
•
Supports egress multicast replication
•
QoS architecture:
–
With DFC3: 2q8t/1p3q8t
–
With CFC: 1q8t/1p3q8t
•
Number of ports: 24
Number of port groups: 2
Port ranges per port group: 1-12, 13-24Supported only with Supervisor Engine 720
12.2(33)SRA
Note
![]()
•
WS-X6724-SFP requires one of the following:
–
WS-F6700-DFC3BXL (3.30 A@42 V)
–
WS-F6700-DFC3B (3.00 A@42 V)
–
WS-X6700-CFC (0.75 A@42 V)
•
WS-X6724-SFP ships with WS-X6700-CFC installed unless ordered with WS-F6700-DFC3BXL or WS-F6700-DFC3B.
•
WS-X6724-SFP is supported in the WS-C6503-E chassis.
•
WS-X6724-SFP is not supported in the WS-C6503 and CISCO7603 chassis.
•
On WS-X6724-SFP ports, STP BPDUs are not exempt from Traffic Storm Control suppression. Do not configure Traffic Storm Control on STP-protected WS-X6724-SFP ports that interconnect network devices.
•
See the "Small Form-Factor Pluggable Modules (SFPs)" section.
WS-X6816-GBIC3.84 A@42 V
16-port Gigabit Ethernet GBIC
•
dCEF256
•
QoS port architecture (Rx/Tx): 1p1q4t/1p2q2t
Number of ports: 16
Number of port groups: 2
Port ranges per port group: 1-8, 9-16With Supervisor Engine 720
12.2(33)SRA
Note
![]()
•
WS-X6816-GBIC requires one of these for use with Supervisor Engine 720:
–
WS-F6K-DFC3BXL (adds 1.47 A@42 V)
–
WS-F6K-DFC3B (adds 1.67 A@42 V)
•
In a 13-slot chassis, WS-X6816-GBIC is supported only in slots 9 through 13 and does not power up in other slots.
WS-X6516A-GBIC3.62 A@42 V
16-port Gigabit Ethernet GBIC
•
CEF256
•
With Supervisor Engine 720:
–
dCEF256 with WS-F6K-DFC3BXL (adds 1.47 A@42 V)
–
dCEF256 with WS-F6K-DFC3B (adds 1.67 A@42 V)
•
1-MB per-port packet buffers
•
Supports egress multicast replication
•
QoS port architecture (Rx/Tx): 1p1q4t/1p2q2t
•
Number of ports: 16
Number of port groups: 2
Port ranges per port group: 1-8, 9-16With Supervisor Engine 720
12.2(33)SRA
With Supervisor Engine 32
12.2(33)SRA
WS-X6516-GBIC3.40 A@42 V
16-port Gigabit Ethernet GBIC
•
CEF256
•
With Supervisor Engine 720:
–
dCEF256 with WS-F6K-DFC3BXL (adds 1.47 A@42 V)
–
dCEF256 with WS-F6K-DFC3B (adds 1.67 A@42 V)
•
512-KB per-port packet buffers
•
QoS port architecture (Rx/Tx): 1p1q4t/1p2q2t
•
Number of ports: 16
Number of port groups: 2
Port ranges per port group: 1-8, 9-16With Supervisor Engine 720
12.2(33)SRA
With Supervisor Engine 32
12.2(33)SRA
Note
![]()
•
Supervisor Engine 720 supports a DFC3 on these WS-X6516-GBIC hardware revisions:
–
Lower than 5.0
–
5.5 and higher
•
Supervisor Engine 720 does not support a DFC3 on WS-X6516-GBIC hardware revisions 5.0 through 5.4. With a Supervisor Engine 720 and with a DFC3 installed, WS-X6516-GBIC hardware revisions 5.0 through 5.4 do not power up.
•
With a Supervisor Engine 720 but without a DFC3, WS-X6516-GBIC hardware revisions 5.0 through 5.4 operate in bus mode.
•
Refer to external field notice 24494 for more information:
WS-X6416-GBIC2.81 A@42 V
16-port Gigabit Ethernet GBIC
•
QoS port architecture (Rx/Tx): 1p1q4t/1p2q2t
•
Number of ports: 16
Number of port groups: 2
Port ranges per port group: 1-8, 9-16With Supervisor Engine 720
12.2(33)SRA
With Supervisor Engine 32
12.2(33)SRA
WS-X6416-GE-MT2.50 A@42 V
16-Port Gigabit Ethernet MT-RJ
•
QoS port architecture (Rx/Tx): 1p1q4t/1p2q2t
•
Number of ports: 16
Number of port groups: 2
Port ranges per port group: 1-8, 9-16With Supervisor Engine 720
12.2(33)SRA
With Supervisor Engine 32
12.2(33)SRA
WS-X6316-GE-TX5.15 A@42 V
16-port Gigabit Ethernet RJ-45
•
QoS port architecture (Rx/Tx): 1p1q4t/1p2q2t
•
Number of ports: 16
Number of port groups: 2
Port ranges per port group: 1-8, 9-16With Supervisor Engine 720
12.2(33)SRA
With Supervisor Engine 32
12.2(33)SRA
Note
Supervisor Engine 32 does not support WS-X6316-GE-TX.
WS-X6408A-GBIC2.00 A@42 V
8-port Gigabit Ethernet GBIC
•
QoS port architecture (Rx/Tx): 1p1q4t/1p2q2t
•
Number of ports: 8
Number of port groups: 1
Port ranges per port group: 1-8With Supervisor Engine 720
12.2(33)SRA
With Supervisor Engine 32
12.2(33)SRA
WS-X6408-GBIC2.00 A@42 V
8-port Gigabit Ethernet GBIC
•
QoS port architecture (Rx/Tx): 1q4t/2q2t
•
Number of ports: 8
Number of port groups: 1
Port ranges per port group: 1-8With Supervisor Engine 720
12.2(33)SRA
With Supervisor Engine 32
12.2(33)SRA
Small Form-Factor Pluggable Modules (SFPs)
These sections describe SFPs:
Gigabit Ethernet SFPs
See the Unsupported Hardware section for information about unsupported DWDM-SFPs.
Fast Ethernet SFPs
Note
Only WS-X6148-FE-SFP supports these Fast Ethernet SFPs.
Product ID
(append "=" for spares) Product Description Minimum Software Version GLC-FE-100FX100BASEFX SFP
12.2(33)SRA
GLC-FE-100LX100BASELX SFP
12.2(33)SRA
10-Gigabit Ethernet Transceiver Modules
Gigabit Interface Converters (GBICs)
Note
The support listed in this section applies to all modules that use GBICs, including OSM LAN ports and OSM Gigabit Ethernet WAN ports.
Power over Ethernet Daughtercards
Note
•
The Power over Ethernet (PoE) daughtercard "Power Required" values do not include the power drawn by phones.
•
Refer to this publication for more information about POE:
http://www.cisco.com/en/US/products/hw/switches/ps708/products_white_paper0900aecd80233a77.shtml
Product ID
(append "=" for spares) Power
Required Product Description Minimum Software Version WS-F6K-FE48X2-AF0.42 A@42 V
IEEE 802.3af PoE daughtercard for WS-X6148X2-RJ-45 and WS-X6196-RJ-21.
With Supervisor Engine 720
12.2(33)SRA
With Supervisor Engine 32
12.2(33)SRA
WS-F6K-GE48-AF0.18 A@42 V
IEEE 802.3af PoE daughtercard for WS-X6548-GE-TX and WS-X6148-GE-TX
With Supervisor Engine 720
12.2(33)SRA
WS-F6K-GE48-AF0.18 A@42 V
IEEE 802.3af PoE daughtercard for WS-X6148-RJ-45 and WS-X6148-RJ-21
With Supervisor Engine 720
12.2(33)SRA
WS-F6K-VPWR-GE0.42 A@42 V
PoE daughtercard for WS-X6548-GE-TX and WS-X6148-GE-TX
With Supervisor Engine 720
12.2(33)SRA
WS-F6K-VPWRNone
PoE daughtercard for WS-X6348-RJ-45, WS-X6348-RJ-21V, WS-X6148-RJ-45, and WS-X6148-RJ-21
With Supervisor Engine 720
12.2(33)SRA
10/100/1000 Ethernet Switching Modules
Product ID
(append "=" for spares) Power
Required Product Description Minimum Software Version WS-X6748-GE-TX7.00 A@42 V
48-port 10/100/1000 RJ-45
•
CEF720 with WS-X6700-CFC (adds 0.75 A@42 V)
•
dCEF720 with WS-F6700-DFC3BXL (adds 3.30 A@42 V)
•
dCEF720 with WS-F6700-DFC3B (adds 3.00 A@42 V)
•
Supports egress multicast replication
•
QoS architecture:
–
With DFC3: 2q8t/1p3q8t
–
With CFC: 1q8t/1p3q8t
•
Number of ports: 48
Number of port groups: 4
Port ranges per port group: 1-12, 13-24, 25-36, 37-48Supported only with Supervisor Engine 720
12.2(33)SRA
Note
![]()
•
WS-X6748-GE-TX requires one of the following:
–
WS-F6700-DFC3BXL (3.30 A@42 V)
–
WS-F6700-DFC3B (3.00 A@42 V)
–
WS-X6700-CFC (0.75 A@42 V)
•
WS-X6748-GE-TX ships with WS-X6700-CFC installed unless ordered with WS-F6700-DFC3BXL or WS-F6700-DFC3B.
•
WS-X6748-GE-TX is supported in the WS-C6503-E chassis.
•
WS-X6748-GE-TX is not supported in the WS-C6503 and CISCO7603 chassis.
•
In a 13-slot chassis, WS-X6748-GE-TX is supported only in slots 9 through 13 and does not power up in other slots.
•
On WS-X6748-GE-TX ports, STP BPDUs are not exempt from Traffic Storm Control suppression. Do not configure Traffic Storm Control on STP-protected WS-X6748-GE-TX ports that interconnect network devices.
WS-X6548-GE-TX
2.98 A@42 V
48-port 10/100/1000 Mbps
•
RJ-45
•
CEF256
•
WS-X6548-GE-TX supports WS-F6K-VPWR-GE and WS-F6K-GE48-AF
•
WS-X6548V-GE-TX supports WS-F6K-VPWR-GE
•
WS-X6548-GE-45AF has WS-F6K-GE48-AF
•
QoS port architecture (Rx/Tx): 1q2t/1p2q2t
Number of ports: 48
Number of port groups: 2
Port ranges per port group: 1-24, 25-48WS-X6548V-GE-TX
3.40 A@42 V
WS-X6548-GE-45AF
3.16 A@42 V
With Supervisor Engine 720
(except WS-F6K-GE48-AF)12.2(33)SRA
WS-F6K-GE48-AF with Supervisor Engine 720
12.2(33)SRA
With Supervisor Engine 32
12.2(33)SRA
WS-F6K-GE48-AF with Supervisor Engine 32
12.2(33)SRA
Note
![]()
•
More than 1 Gbps of traffic per EtherChannel is supported on the WS-X6548-GE-TX (and voice-power daughtercard-equipped) switching modules.
•
WS-X6548-GE-TX and WS-X6548V-GE-TX do not support these features:
–
ISL trunking
–
Jumbo frames
–
802.1Q tunneling
–
Traffic storm control
WS-X6148A-GE-TX
2.50 A@42 V
48-port 10/100/1000 Mbps
•
RJ-45
•
WS-X6148A-GE-TX supports WS-F6K-GE48-AF
•
WS-X6148A-GE-45AF has WS-F6K-GE48-AF
•
QoS port architecture (Rx/Tx): 1q2t/1p2q2t
•
Number of ports: 48
Number of port groups: 2
Port ranges per port group: 1-24, 25-48 WS-X6148-GE-45AF2.68 A@42 V
With Supervisor Engine 720
12.2(33)SRA
With Supervisor Engine 32
12.2(33)SRA
Note
WS-X6148A-GE-TX and WS-X6148A-GE-45AF do not support these features:
•
More than 1 Gbps of traffic per EtherChannel
•
WS-F6K-DFC3B, or WS-F6K-DFC3BXL
•
ISL trunking
•
Jumbo frames
•
802.1Q tunneling
•
Traffic storm control
WS-X6148-GE-TX
2.47 A@42 V
48-port 10/100/1000 Mbps
WS-X6148V-GE-TX
2.89 A@42 V
•
RJ-45
WS-X6148-GE-45AF2.65 A@42 V
•
WS-X6148-GE-TX supports WS-F6K-VPWR-GE and WS-F6K-GE48-AF
•
WS-X6148V-GE-TX has WS-F6K-VPWR-GE
•
WS-X6148-GE-45AF has WS-F6K-GE48-AF
•
QoS port architecture (Rx/Tx): 1q2t/1p2q2t
•
Number of ports: 48
Number of port groups: 2
Port ranges per port group: 1-24, 25-48With Supervisor Engine 720
(except WS-F6K-GE48-AF)12.2(33)SRA
WS-F6K-GE48-AF with Supervisor Engine 720
12.2(33)SRA
With Supervisor Engine 32
12.2(33)SRA
WS-F6K-GE48-AF with Supervisor Engine 32
12.2(33)SRA
Note
WS-X6148-GE-TX, WS-X6148V-GE-TX, and WS-X6148-GE-45AF do not support these features:
•
More than 1 Gbps of traffic per EtherChannel
•
WS-F6K-DFC3B, or WS-F6K-DFC3BXL
•
ISL trunking
•
Jumbo frames
•
802.1Q tunneling
•
Traffic storm control
WS-X6516-GE-TX3.45 A@42 V
16-port 10/100/1000BASE-T
•
CEF256
•
With Supervisor Engine 720:
–
dCEF256 with WS-F6K-DFC3BXL (adds 1.47 A@42 V)
–
dCEF256 with WS-F6K-DFC3B (adds 1.67 A@42 V)
•
QoS port architecture (Rx/Tx): 1p1q4t/1p2q2t
•
Number of ports: 16
Number of port groups: 2
Port ranges per port group: 1-8, 9-16With Supervisor Engine 720
12.2(33)SRA
With Supervisor Engine 32
12.2(33)SRA
Fast Ethernet Switching Modules
Product ID
(append "=" for spares) Power
Required Product Description Minimum Software Version WS-X6148-FE-SFP2.30 A@42 V
48-port 100BASE-FX
•
Requires Fast Ethernet SFPs
•
QoS port architecture (Rx/Tx): 1p1q4t/1p3q8t
With Supervisor Engine 720
12.2(33)SRA
With Supervisor Engine 32
12.2(33)SRA
WS-X6524-100FX-MM1.90 A@42 V
24-port 100FX Ethernet multimode
•
CEF256
•
With Supervisor Engine 720:
–
dCEF256 with WS-F6K-DFC3BXL (adds 1.47 A@42 V)
–
dCEF256 with WS-F6K-DFC3B (adds 1.67 A@42 V)
•
QoS port architecture (Rx/Tx): 1p1q0t/1p3q1t
•
Number of ports: 24
Number of port groups: 1
Port ranges per port group: 1-24With Supervisor Engine 720
12.2(33)SRA
With Supervisor Engine 32
12.2(33)SRA
WS-X6324-100FX-SM1.52 A@42 V
24-port 100FX Ethernet
WS-X6324-100FX-MM1.52 A@42 V
•
Single-mode and multimode MT-RJ
•
128-KB per-port packet buffers
•
QoS port architecture (Rx/Tx): 1q4t/2q2t
•
Number of ports: 24
Number of port groups: 2
Port ranges per port group: 1-12, 13-24With Supervisor Engine 720
12.2(33)SRA
With Supervisor Engine 32
12.2(33)SRA
WS-X6224-100FX-MT1.90 A@42 V
24-port 100FX Ethernet Multimode MT-RJ
•
QoS port architecture (Rx/Tx): 1q4t/2q2t
•
Number of ports: 24
Number of port groups: 2
Port ranges per port group: 1-12, 13-24With Supervisor Engine 720
12.2(33)SRA
With Supervisor Engine 32
12.2(33)SRA
Ethernet/Fast Ethernet (10/100) Switching Modules
Product ID
(append "=" for spares) Power
Required Product Description Minimum Software Version WS-X6548-RJ-452.90 A@42 V
48-port 10/100TX RJ-45
•
CEF256
•
With Supervisor Engine 720:
–
dCEF256 with WS-F6K-DFC3BXL (adds 1.47 A@42 V)
–
dCEF256 with WS-F6K-DFC3B (adds 1.67 A@42 V)
•
QoS port architecture (Rx/Tx): 1p1q0t/1p3q1t
•
Number of ports: 48
Number of port groups: 1
Port ranges per port group: 1-48With Supervisor Engine 720
12.2(33)SRA
With Supervisor Engine 32
12.2(33)SRA
WS-X6548-RJ-212.90 A@42 V
48-port 10/100TX RJ-21
•
CEF256
•
With Supervisor Engine 720:
–
dCEF256 with WS-F6K-DFC3BXL (adds 1.47 A@42 V)
–
dCEF256 with WS-F6K-DFC3B (adds 1.67 A@42 V)
•
QoS port architecture (Rx/Tx): 1p1q0t/1p3q1t
•
Number of ports: 48
Number of port groups: 1
Port ranges per port group: 1-48With Supervisor Engine 720
12.2(33)SRA
With Supervisor Engine 32
12.2(33)SRA
WS-X6148X2-RJ-45
2.65 A@42 V
96-port 10/100TX RJ-45
WS-X6148X2-45AF2.92 A@42 V
•
QoS port architecture (Rx/Tx): 1p1q0t/1p3q1t
•
WS-X6148X2-RJ-45 supports WS-F6K-FE48X2-AF
•
WS-X6148X2-45AF has WS-F6K-FE48X2-AF
With Supervisor Engine 720
12.2(33)SRA
With Supervisor Engine 32
12.2(33)SRA
WS-X6196-RJ-212.74 A@42 V
96-port 10/100TX RJ-21
WS-X6196-21AF3.16 A@42 V
•
QoS port architecture (Rx/Tx): 1p1q0t/1p3q1t
•
WS-X6196-RJ-21 supports WS-F6K-FE48X2-AF
•
WS-X6196-21AF has WS-F6K-FE48X2-AF
With Supervisor Engine 720
12.2(33)SRA
With Supervisor Engine 32
12.2(33)SRA
WS-X6348-RJ-452.39 A@42 V
48-port 10/100TX RJ-45
WS-X6348-RJ-45V2.39 A@42 V
•
128-KB per-port packet buffers
•
QoS port architecture (Rx/Tx): 1q4t/2q2t
•
WS-X6348-RJ-45 supports WS-F6K-VPWR
•
WS-X6348-RJ-45V has WS-F6K-VPWR
•
Number of ports: 48
Number of port groups: 4
Port ranges per port group: 1-12, 13-24, 25-36, 37-48With Supervisor Engine 720
12.2(33)SRA
With Supervisor Engine 32
12.2(33)SRA
WS-X6348-RJ-21V2.39 A@42 V
48-port 10/100TX RJ-21
•
128-KB per-port packet buffers
•
QoS port architecture (Rx/Tx): 1q4t/2q2t
•
Has WS-F6K-VPWR
•
Number of ports: 48
Number of port groups: 4
Port ranges per port group: 1-12, 13-24, 25-36, 37-48With Supervisor Engine 720
12.2(33)SRA
With Supervisor Engine 32
12.2(33)SRA
WS-X6248-RJ-452.69 A@42 V
48-port 10/100TX RJ-45
•
QoS port architecture (Rx/Tx): 1q4t/2q2t
•
Number of ports: 48
Number of port groups: 4
Port ranges per port group: 1-12, 13-24, 25-36, 37-48With Supervisor Engine 720
12.2(33)SRA
With Supervisor Engine 32
12.2(33)SRA
WS-X6248A-TEL2.69 A@42 V
48-port 10/100TX RJ-21
•
128-KB per-port packet buffers
•
QoS port architecture (Rx/Tx): 1q4t/2q2t
•
Number of ports: 48
Number of port groups: 4
Port ranges per port group: 1-12, 13-24, 25-36, 37-48With Supervisor Engine 720
12.2(33)SRA
With Supervisor Engine 32
12.2(33)SRA
WS-X6248-TEL2.69 A@42 V
48-port 10/100TX RJ-21
•
QoS port architecture (Rx/Tx): 1q4t/2q2t
•
Number of ports: 48
Number of port groups: 4
Port ranges per port group: 1-12, 13-24, 25-36, 37-48With Supervisor Engine 720
12.2(33)SRA
With Supervisor Engine 32
12.2(33)SRA
WS-X6148A-RJ-45
WS-X6148A-45AF2.39 A@42 V
2.57 A@42 V48-port 10/100TX RJ-45
•
128-KB per-port packet buffers
•
QoS port architecture (Rx/Tx): 1q4t/2q2t
•
WS-X6148A-RJ-45 supports WS-F6K-GE48-AF
•
WS-X6148A-45AF has WS-F6K-GE48-AF
•
Number of ports: 48
Number of port groups: 4
Port ranges per port group: 1-12, 13-24, 25-36, 37-48With Supervisor Engine 720
12.2(33)SRA
With Supervisor Engine 32
12.2(33)SRA
WS-X6148-RJ-452.39 A@42 V
48-port 10/100TX RJ-45
WS-X6148-RJ-45V2.39 A@42 V
128-KB per-port packet buffers
WS-X6148-45AF2.57 A@42 V
QoS port architecture (Rx/Tx): 1q4t/2q2t
•
WS-X6148-RJ-45 supports WS-F6K-VPWR and WS-F6K-GE48-AF
•
WS-X6148-RJ-45V has WS-F6K-VPWR
•
WS-X6148-45AF has WS-F6K-GE48-AF
•
Number of ports: 48
Number of port groups: 4
Port ranges per port group: 1-12, 13-24, 25-36, 37-48With Supervisor Engine 720
(except with WS-F6K-GE48-AF)12.2(33)SRA
WS-F6K-GE48-AF with Supervisor Engine 720
12.2(33)SRA
With Supervisor Engine 32
12.2(33)SRA
WS-F6K-GE48-AF with Supervisor Engine 32
12.2(33)SRA
WS-X6148-RJ-212.39 A@42 V
48-port 10/100TX RJ-21
WS-X6148-RJ-21V2.39 A@42 V
•
128-KB per-port packet buffers
WS-X6148-21AF2.57 A@42 V
•
QoS port architecture (Rx/Tx): 1q4t/2q2t
•
WS-X6148-RJ-21 supports WS-F6K-VPWR and WS-F6K-GE48-AF
•
WS-X6148-RJ-21V has WS-F6K-VPWR
•
WS-X6148-21AF has WS-F6K-GE48-AF
•
Number of ports: 48
Number of port groups: 4
Port ranges per port group: 1-12, 13-24, 25-36, 37-48With Supervisor Engine 720
(except WS-F6K-GE48-AF)12.2(33)SRA
WS-F6K-GE48-AF with Supervisor Engine 720
12.2(33)SRA
With Supervisor Engine 32
12.2(33)SRA
WS-F6K-GE48-AF with Supervisor Engine 32
12.2(33)SRA
Ethernet Switching Modules
Optical Services Modules (OSMs)
•
OSM Guidelines and Restrictions
•
CT3/T1 Channelized/Unchannelized
OSM Guidelines and Restrictions
•
Supervisor Engine 32 does not support OSMs.
•
OSMs require a minimum of 128 MB of synchronous dynamic random-access memory (SDRAM) —Refer to this publication for memory upgrade procedures:
http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/hardware/osmodule/app_upgr.htm
•
OSMs are CEF256 modules.
•
OSM WAN port numbering starts with 1.
•
On OSMs with Gigabit Ethernet GBIC Layer 2 LAN ports:
–
OSM LAN port numbering starts with 1.
–
The LAN ports are in a single port group.
•
The OSM-2+4GE-WAN+ and the OC-12 Packet-over-SONET OSMs have been tested with the service modules and WS-SUP720.
Gigabit Ethernet WAN
OC-48 Packet over SONET
Note
Also has four Layer 2 LAN ports.
OC-48 DPT/Packet over SONET
Note
Also has four Layer 2 LAN ports.
OC-12 Packet over SONET
Note
Also has four Layer 2 LAN ports.
OC-3 Packet over SONET
Note
Also has four Layer 2 LAN ports.
OC-12 Channelized
Note
Also has four Layer 2 LAN ports.
CT3/T1 Channelized/Unchannelized
Note
OSM-12CT3/T1 has mini-SMB connectors for use with 75-ohm copper coaxial cable.
OC-12 ATM
Note
Also has four Layer 2 LAN ports.
SPA Interface Processors (SIPs)
Note
See the Release Notes for Cisco IOS Release 12.2SR on the Cisco 7600 Series Routers for information about additional procedures required to support SIPs with Cisco IOS Release 12.2(33)SRA and later releases.
Shared Port Adapters (SPAs)
These sections describe SPAs:
•
POS SPAs
•
ATM SPAs
•
Circuit Emulation over Packet (CEoP) SPAs
Ethernet SPAs
These sections describe Ethernet SPAs:
Ten Gigabit Ethernet SPAs
Gigabit Ethernet SPAs
Fast Ethernet SPAs
POS SPAs
ATM SPAs
Serial SPAs
Circuit Emulation over Packet (CEoP) SPAs
Services SPA Carrier (SSC)
Services SPAs
Enhanced FlexWAN Module
Product ID
(append "=" for spares) Power
Required Product Description Minimum Software Version WS-X6582-2PA2.50 A@42 V
Enhanced FlexWAN Module; CEF256
With Supervisor Engine 720
12.2(33)SRA
With Supervisor Engine 32
12.2(33)SRA
Note
See the Release Notes for Cisco IOS Release 12.2SR on the Cisco 7600 Series Routers for information about additional procedures required to support WS-X6582-2PA with Cisco IOS Release 12.2(33)SRA and later releases.
Enhanced FlexWAN Module Port Adapters
Product ID
(append "=" for spares) Product Description Minimum Software Version PA-2FE-TX, -FX2-port Fast Ethernet port adapter (supported only in WS-X6582-2PA)
12.2(33)SRA
PA-1FE-TX, -FX1-port Fast Ethernet port adapter (supported only in WS-X6582-2PA)
12.2(33)SRA
PA-POS-1OC31-port Packet over SONET OC3c/STM1 port adapter
12.2(33)SRA
PA-POS-2OC32-port POS OC3c/STM1 port adapter
12.2(33)SRA
SFPs for PA-POS-2OC3 SFP-OC3-MMShort range, multimode fiber
12.2(33)SRA
SFP-OC3-IR1Intermediate range, single-mode fiber
12.2(33)SRA
SFP-OC3-LR1Long range, single-mode fiber
12.2(33)SRA
PA-A6-OC3MM1-port ATM OC-3c/STM-1 multimode port adapter, enhanced
12.2(33)SRA
PA-A6-OC3SMI1-port ATM OC-3c/STM-1 single-mode (IR) port adapter, enhanced
12.2(33)SRA
PA-A6-OC3SML1-port ATM OC-3c/STM-1 single-mode (LR) port adapter, enhanced
12.2(33)SRA
PA-A6-T31-port ATM DS3 port adapter, enhanced
12.2(33)SRA
PA-A6-E31-port ATM E3 port adapter, enhanced
12.2(33)SRA
PA-POS-OC3MM
PA-POS-OC3SMI
PA-POS-OC3SMLPacket over SONET (OC-3) port adapters
12.2(33)SRA
PA-A3-OC3MM
PA-A3-OC3SMI
PA-A3-T3
PA-A3-OC3SML
PA-A3-E3
PA-A3-8T1IMA
PA-A3-8E1IMAATM with traffic shaping port adapters
12.2(33)SRA
PA-T3
PA-T3+
PA-2T3
PA-2T3+
PA-E3
PA-2E3
PA-MC-T3
PA-MC-E3
PA-MC-2T3+T3/E3 (clear-channel and channelized) port adapters
12.2(33)SRA
PA-4T+
PA-8T-V35
PA-8T-X21
PA-8T-232
PA-MC-2E1/120
PA-MC-8T1
PA-MC-8E1/120
PA-MC-2T1
PA-MC-4T1T1/E1 port adapters
12.2(33)SRA
PA-4E1G/75
PA-4E1G/120T1/E1 port adapters
12.2(33)SRA
PA-MC-8TE1+Multichannel T1/E1 8PRI port adapters
12.2(33)SRA
PA-H
PA-2HHSSI port adapters
12.2(33)SRA
PA-MC-STM-1Multichannel STM-1 port adapters
12.2(33)SRA
Ethernet Services 20G Line Cards
Service Modules
•
Traffic Anomaly Detector Module
•
Persistent Storage Device (PSD) Module
•
Multi-Processor WAN Application Module (MWAM)
•
Content Services Gateway (CSG) Module
•
Intrusion Detection System Modules (IDSMs)
•
Network Analysis Modules (NAMs)
•
Application Control Engine (ACE) Module
•
Service Application Module for IP
Anomaly Guard Module
Product ID
(append "=" for spares) Power
Required Product Description Minimum Software Version WS-SVC-AGM-1-K94.00 A@42 V
Anomaly Guard Module
With Supervisor Engine 720
12.2(33)SRA
With Route Switching Processor 720-1GE
12.2(33)SRC
With Route Switching Processor 720-1GE
12.2(33)SRC
Note
![]()
•
Supervisor Engine 32 does not support WS-SVC-AGM-1-K9.
•
WS-SVC-AGM-1-K9 runs its own software—Refer to this publication:
http://www.cisco.com/univercd/cc/td/doc/product/secure/ad_g/jaffa/jaffaagd.htm
Traffic Anomaly Detector Module
Product ID
(append "=" for spares) Power
Required Product Description Minimum Software Version WS-SVC-ADM-1-K94.00 A@42 V
Traffic Anomaly Detector Module
With Supervisor Engine 720
12.2(33)SRA
With Route Switching Processor 720-1GE
12.2(33)SRC
With Route Switching Processor 720-1GE
12.2(33)SRC
Note
![]()
•
Supervisor Engine 32 does not support WS-SVC-ADM-1-K9.
•
WS-SVC-ADM-1-K9 runs its own software—Refer to this publication:
http://www.cisco.com/univercd/cc/td/doc/product/secure/ad_g/jaffa/jaffatad.htm
Persistent Storage Device (PSD) Module
Product ID
(append "=" for spares) Power
Required Product Description Minimum Software Version WS-SVC-PSD-14.00 A@42 V
Persistent Storage Device Module
With Supervisor Engine 720
12.2(33)SRA
With Supervisor Engine 32
12.2(33)SRC
Note
![]()
•
WS-SVC-PSD-1 runs its own software—See this publication for more information:
•
http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/relnotes/ol_4781.htm
•
WS-SVC-PSD-1 maintains state when an NSF with SSO redundancy mode switchover occurs.
•
Route Switching Processor 720 does not support WS-SVC-PSD-1.
Multi-Processor WAN Application Module (MWAM)
Product ID
(append "=" for spares) Power
Required Product Description Minimum Software Version WS-SVC-MWAM-13.57 A@42 V
Multi-Processor WAN Application Module
With Supervisor Engine 720
12.2(33)SRA
With Supervisor Engine 32
12.2(33)SRC
Note
![]()
•
Route Switching Processor 720 does not support WS-SVC-MWAM-1.
•
WS-SVC-MWAM-1 runs its own software—See this publication for more information:
http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/relnotes/mwam/index.htm
•
WS-SVC-MWAM-1 maintains state when an NSF with SSO redundancy mode switchover occurs.
Content Services Gateway (CSG) Module
Product ID
(append "=" for spares) Power
Required Product Description Minimum Software Version WS-SVC-CSG-13.00 A@42 V
Content Services Gateway (CSG) Module
With Supervisor Engine 720
12.2(33)SRA
With Supervisor Engine 32
12.2(33)SRC
Explanation
•
WS-SVC-CSG-1 runs its own software—Refer to this publication for more information:
http://www.cisco.com/univercd/cc/td/doc/product/wireless/moblwrls/csg/index.htm
Firewall Services Module
Product ID
(append "=" for spares) Power
Required Product Description Minimum Software Version WS-SVC-FWM-1-K94.09 A@42 V
Firewall Services Module; CEF256
With Route Switching Processor 720-1GE
12.2(33)SRC
With Supervisor Engine 720
12.2(33)SRA
With Supervisor Engine 32
12.2(33)SRA
Note
![]()
•
Supervisor Engine 32 requires Firewall Services Module Software Release 2.3(3) or a later rebuild.
•
WS-SVC-FWM-1-K9 runs its own software—See this publication for more information:
http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/mod_icn/fwsm/index.htm
•
With Firewall Services Module Software Release 2.3(1), WS-SVC-FWM-1-K9 maintains state when an NSF with SSO redundancy mode switchover occurs.
•
WS-SVC-FWM-1-K9 does not maintain state when a single router mode with stateful switchover (SRM with SSO) redundancy mode switchover occurs.
Intrusion Detection System Modules (IDSMs)
Product ID
(append "=" for spares) Power
Required Product Description Minimum Software Version WS-SVC-IDSM2-K92.50 A@42 V
Intrusion Detection System Module 2; CEF256
With Supervisor Engine 720
12.2(33)SRA
With Route Switching Processor 720-1GE
12.2(33)SRC
With Supervisor Engine 32
12.2(33)SRC
Note
![]()
•
WS-SVC-IDSM2-K9 runs its own software—See this publication for more information:
http://www.cisco.com/univercd/cc/td/doc/product/iaabu/csids/csids10/4029_02.htm
•
WS-SVC-IDSM2-K9 has been tested with OSM-2+4GE-WAN+ and the OC-12 Packet-over-SONET OSMs.
Network Analysis Modules (NAMs)
Product ID
(append "=" for spares) Power
Required Product Description Minimum Software Version WS-SVC-NAM-23.47 A@42 V
Network Analysis Module 2; CEF256
With Supervisor Engine 720
12.2(33)SRC
With Supervisor Engine 32
12.2(33)SRC
With Route Switching Processor 720-1GE
12.2(33)SRC
WS-SVC-NAM-12.89 A@42 V
Network Analysis Module 1; CEF256
With Supervisor Engine 720
12.2(33)SRA
With Supervisor Engine 32
12.2(33)SRA
With Route Switching Processor 720-1GE
12.2(33)SRC
Note
![]()
•
WS-SVC-NAM-2 and WS-SVC-NAM-1 run their own software—See this publication for more information:
http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/relnotes/78_15353.htm
•
WS-SVC-NAM-2 and WS-SVC-NAM-1 have been tested with OSM-2+4GE-WAN+ and the OC-12 Packet-over-SONET OSMs.
Application Control Engine (ACE) Module
Service Application Module for IP
Wireless Services Module (WiSM)
Product ID
(append "=" for spares) Power
Required Product Description Minimum Software Version WS-SVC-WISM-1-K96.07 A@42 V
Wireless Services Module (WiSM)
With Supervisor Engine 720
12.2(33)SRC
With Route Switching Processor 720-1GE
12.2(33)SRC
•
WS-SVC-WISM-1-K9 runs its own software—See these publications:
•
http://www.cisco.com/univercd/cc/td/doc/product/wireless/control/c44/index.htm
•
See the WS-SVC-WISM-1-K9 software release notes for information about the minimum required WS-SVC-WISM-1-K9 software version.
Note
![]()
•
Supervisor Engine 32 does not support WS-SVC-WISM-1-K9.
•
RSP720 does not support WS-SVC-WISM-1-K9.
•
In a 13-slot chassis, WS-SVC-WISM-1-K9 is supported only in slots 9 through 13 and does not power up in other slots.
Fan Trays
Note
The fan trays required by the Supervisor Engine 720 are supported only with the power supplies listed in the " WS-C6503, WS-C6503-E, and CISCO7603 Power Supplies" and " CISCO7603-S Power Supplies" sections.
Note
Enter the show environment status | include fan command or the show environment cooling command to display information about the installed fan trays.
High-Capacity Fan Trays
These high-capacity fan trays support the Supervisor Engine 720.
Product ID
(append "=" for spares) Power
Allocated at 42 V Product Description Minimum
Software
Version WS-C6503-E-FAN1.37 A@42 V
High-capacity fan tray for WS-C6503-E chassis
12.2(33)SRA
FAN-MOD-3HS2.98 A@42 V
12.2(33)SRA
FAN-MOD-6HS4.29 A@42 V
High-capacity fan tray for CISCO7606 chassis
12.2(33)SRA
WS-C6506-E-FAN2.35 A@42 V
High-capacity fan tray for WS-C6506-E chassis
12.2(33)SRA
WS-C6K-6SLOT-FAN212 V fan
High-capacity fan tray for WS-C6506 chassis
12.2(33)SRA
FAN-MOD-095.75 A@42 V
High-capacity fan tray for WS-C6509-NEB-A and CISCO7609 chassis
12.2(33)SRA
WS-C6509-E-FAN3.58 A@42 V
High-capacity fan tray for WS-C6509-E chassis
12.2(33)SRA
WS-C6K-9SLOT-FAN212 V fan
High-capacity fan tray for WS-C6509 chassis
12.2(33)SRA
WS-C6K-13SLT-FAN27.10 A@42 V
12.2(33)SRA
Power Supplies
•
WS-C6504-E and CISCO7604 Power Supplies
•
WS-C6503, WS-C6503-E, and CISCO7603 Power Supplies
CISCO7606 Power Supplies
CISCO7606-S Power Supplies
Product ID
(append "=" for spares) Product Description Minimum Software Version PWR-2700-AC2700 W AC power supply
12.2(33)SRB1
PWR-2700-DC2700 W DC power supply
12.2(33)SRB1
WS-C6504-E and CISCO7604 Power Supplies
Product ID
(append "=" for spares) Product Description Minimum Software Version PWR-2700-DC/42700 W DC power supply
12.2(33)SRA
WS-C6503, WS-C6503-E, and CISCO7603 Power Supplies
CISCO7603-S Power Supplies
Product ID
(append "=" for spares) Product Description Minimum Software Version PWR-1500-DC1500 W DC input (PWR-1500-DC)
12.2(33)SRB1
All Other Power Supplies
Product ID
(append "=" for spares) Product Description Minimum Software Version WS-CAC-6000W6000 W AC power supply
12.2(18)SXD
PWR-4000-DC4000 W DC power supply
12.2(33)SRA
WS-CAC-4000W4000 W AC power supply
12.2(33)SRA
+WS-CAC-3000W3000 W AC power supply
Note
![]()
•
Required with Supervisor Engine 720 in WS-C6509-NEB or OSR7609.
•
Included in the WS-6509-NEB-UPGRD= upgrade kit.
12.2(33)SRA
WS-CAC-3000W3000 W AC power supply
12.2(33)SRA
WS-CAC-2500W2500 W AC power supply
12.2(33)SRA
WS-CDC-2500W2500 W DC power supply
12.2(33)SRA
PWR-6000-DC6000 W DC power supply
12.2(33)SRB
Chassis
Note
Cisco IOS Release 12.2SR is developed for and intended to run on Cisco 7600 series routers. If you are interrested in running this release on Cisco Catalyst 6500 series switches, contact your account team.
13-Slot Chassis
Product ID
(append "=" for spare) Product Description Minimum Software Version WS-C6513Catalyst 6513 chassis:
•
13 slots
•
64 chassis MAC addresses
•
Use with Supervisor Engine 720 requires WS-C6K-13SLT-FAN2
•
Does not support WS-C6500-SFM
•
These modules are supported only in slots 9 through 13 and do not power up in other slots:
With Supervisor Engine 720
12.2(33)SRA
With Supervisor Engine 32
12.2(33)SRA
CISCO7613Cisco 7613 chassis:
•
13 slots
•
64 chassis MAC addresses
•
Use with Supervisor Engine 720 requires WS-C6K-13SLT-FAN2
•
Does not support WS-C6500-SFM
•
These modules are supported only in slots 9 through 13 and do not power up in other slots:
With Supervisor Engine 720
12.2(33)SRA
With Supervisor Engine 32
12.2(33)SRA
With Route Switch Processor 720
12.2(33)SRB
9-Slot Chassis
Product ID
(append "=" for spare) Product Description Minimum Software Version WS-C6509-ECatalyst 6509 chassis:
•
9 horizontal slots
•
1024 chassis MAC addresses
•
Requires WS-C6509-E-FAN
•
Requires 2500 W or higher power supply
With Supervisor Engine 720
12.2(33)SRA
With Supervisor Engine 32
12.2(33)SRA
WS-C6509Catalyst 6509 chassis:
•
9 horizontal slots
•
1024 chassis MAC addresses
•
Use with Supervisor Engine 720 requires WS-C6K-9SLOT-FAN2
•
WS-CAC-6000W limited to 4000 W in WS-C6509
With Supervisor Engine 720
12.2(33)SRA
With Supervisor Engine 32
12.2(33)SRA
WS-C6509-NEB-ACatalyst 6509-NEB chassis
•
9 vertical slots
•
64 chassis MAC addresses
•
No fan tray upgrade required for use with Supervisor Engine 720
With Supervisor Engine 720
12.2(33)SRA
With Supervisor Engine 32
12.2(33)SRA
CISCO7609Cisco 7609 chassis
•
9 vertical slots
•
64 chassis MAC addresses
•
No fan tray upgrade required for use with Supervisor Engine 720
With Supervisor Engine 720
12.2(33)SRA
With Supervisor Engine 32
12.2(33)SRA
With Route Switch Processor 720
12.2(33)SRB
CISCO7609-SCisco 7609-S chassis
•
9 vertical slots
•
64 chassis MAC addresses
•
FAN-MOD-9SHS high-speed fan module
•
No fan tray upgrade required for use with Supervisor Engine 720
With Supervisor Engine 720
12.2(33)SRB
With Supervisor Engine 32
12.2(33)SRB
With Route Switch Processor 720
12.2(33)SRB
6-Slot Chassis
Product ID
(append "=" for spare) Product Description Minimum Software Version WS-C6506-ECatalyst 6506 chassis:
•
6 slots
•
1024 chassis MAC addresses
•
Requires WS-C6506-E-FAN
•
Requires 2500 W or higher power supply
With Supervisor Engine 720
12.2(33)SRA
With Supervisor Engine 32
12.2(33)SRA
WS-C6506Catalyst 6506 chassis:
•
6 slots
•
1024 chassis MAC addresses
•
Use with Supervisor Engine 720 requires WS-C6K-6SLOT-FAN2
•
WS-CAC-6000W limited to 4000 W in WS-C6506
With Supervisor Engine 720
12.2(33)SRA
With Supervisor Engine 32
12.2(33)SRA
CISCO7606Cisco 7606 chassis:
•
6 slots
•
64 chassis MAC addresses
•
Use with Supervisor Engine 720 requires FAN-MOD-6HS
With Supervisor Engine 720
12.2(33)SRA
With Supervisor Engine 32
12.2(33)SRA
With Route Switch Processor 720
12.2(33)SRB
CISCO7606-SCisco 7606-S chassis
•
6 vertical slots
•
64 chassis MAC addresses
•
FAN-MOD-6SHS high-speed fan module
•
No fan tray upgrade required for use with Supervisor Engine 720
With Supervisor Engine 720
12.2(33)SRB1
With Supervisor Engine 32
12.2(33)SRB1
With Route Switch Processor 720
12.2(33)SRB1
4-Slot Chassis
3-Slot Chassis
Product ID
(append "=" for spare) Product Description Minimum Software Version WS-C6503-E•
3 slots
•
64 chassis MAC addresses
•
Use with Supervisor Engine 720 requires WS-C6503-E-FAN
•
WS-C6503-E supports:
•
WS-C6503-E does not support:
With Supervisor Engine 720
12.2(33)SRA
With Supervisor Engine 32
12.2(33)SRA
CISCO7603-SCisco 7603-S chassis
•
3 slots
•
64 chassis MAC addresses
•
FAN-MOD-3SHS high-speed fan module
•
No fan tray upgrade required for use with Supervisor Engine 720
With Supervisor Engine 720
12.2(33)SRB1
With Supervisor Engine 32
12.2(33)SRB1
With Route Switch Processor 720
12.2(33)SRB1
Unsupported Hardware
The following hardware is not supported:
•
See the "Supervisor Engine 32" section for information about hardware that is not supported with the Supervisor Engine 32.
•
1000BASE-BX10 SFP (GLC-BX-U, GLC-BX-U)
•
The SFP-GE-S, SFP-GE-L, SFP-GE-Z, and SFP-GE-T are not supported on WS-X67xx-SFPs or on Supervisor Engine 720 uplink GE ports.
•
With a Supervisor Engine 720, WS-X6516-GBIC hardware revisions 5.0 through 5.4 with a DFC3 installed.
Supervisor Engine 720 supports a DFC3 on these WS-X6516-GBIC hardware revisions:
–
Lower than 5.0
–
5.5 and higher
With a Supervisor Engine 720 and a DFC3 installed, WS-X6516-GBIC hardware revisions 5.0 through 5.3 do not power up. Without a DFC3, WS-X6516-GBIC hardware revisions 5.0 through 5.4 operate in bus mode.
Refer to external field notice 24494 for more information:
http://www.cisco.com/warp/public/770/fn24494.shtml
Additionally, the following hardware is not supported:
Unsupported Service Modules
•
WS-X6381-IDS—Intrusion Detection System (IDS) Module
•
WS-X6380-NAM—Network Analysis Module (NAM)
•
WS-SVC-WLAN-1-K9—Wireless LAN Service Module
•
WS-SVC-IPSEC-1—IPsec VPN Acceleration Services Module
•
WS-SVC-WEBVPN-K9—WebVPN Services Module
•
WS-SVC-CMM—Communication Media Module
•
WS-X6066-SLB-S-K9—Content Switching Module with SSL (CSM-S)
•
WS-X6066-SLB-APC—Content Switching Module (CSM)
•
WS-SVC-AON-1-K9—Application-Oriented Networking Module (AON)
•
WS-SVC-SSL-1—Secure Sockets Layer (SSL) Services Module
Unsupported Port Adapters
–
WS-SVC-CMM-24FXS—24-Port FXS Interface Port Adapter
–
WS-SVC-CMM-ACT—Adhoc Conferencing and Transcoding Port Adapter
–
WS-SVC-CMM-6T1—6-Port T1 Interface Port Adapter
–
WS-SVC-CMM-6E1—6-Port E1 Interface Port Adapter
Unsupported Supervisor Engines
•
Supervisor Engine 1 (WS-X6K-S1A-MSFC2, WS-X6K-SUP1A-MSFC)
•
Supervisor Engine 2 (WS-X6K-S2U-MSFC2, WS-X6K-S2-MSFC2)
Unsupported Policy Feature Cards and Distributed Forwarding Cards
•
PFC2
•
PFC3A (WS-F6K-PFC3A)
•
DFC3A (WS-F6700-DFC3A )
Unsupported Line Cards
•
FlexWAN module (WS-X6182-2PA)
•
OSM-4GE-WAN-GBIC
•
OSM-1OC48-POS-SS, SI, SL
•
OSM-4OC12-POS-MM, SI, SL
•
OSM-2OC12-POS-MM, SI, SL
•
OSM-16OC3-POS-MM, SI, SL
•
OSM-8OC3-POS-MM, SI, SL
•
OSM-4OC3-POS-SI
•
OSM-2OC12-ATM-MM, SI
Unsupported Service Modules
•
WS-X6624-FXS, WS-X6608-T1, and WS-X6608-E1 voice modules
•
WS-X6101-OC12-MMF and WS-X6101-OC12-SMF ATM LANE modules
•
WS-X6302-MSM—Multilayer Switch Module
Unsupported Chassis
•
Catalyst 6000 series chassis
•
WS-C6509-NEB—Catalyst 6509-NEB chassis
•
OSR-7609—Cisco 7609 chassis
•
CISCO7603—Cisco 7603 chassis
•
WS-C6503—Catalyst 6503 chassis
Unsupported Power Supplies
These power supplies cannot support high-capacity fan trays:
–
WS-CAC-1300W
–
WS-CDC-1300W
–
WS-CAC-1000W
Note
Unsupported modules remain powered down if detected and do not affect system behavior.
Related Documentation
The following publications are available for the Cisco 7600 series routers:
•
Cisco 7600 Series Router Installation Guide
•
Cisco 7600 Series Router Module Installation Guide
•
Cisco 7600 Series Router SIP, SSC, and SPA Hardware Installation Guide
•
Cisco 7600 Series Router SIP, SSC, and SPA Software Configuration Guide
•
Cisco 7600 Series Router Cisco IOS Command Reference
•
Cisco 7600 Series Internet Router System Message Guide
•
Release Notes for Cisco IOS Release 12.2SRA on the Cisco 7600 Series Routers
•
Cisco IOS Configuration Guides and Command References—Use these publications to help you configure Cisco IOS software features not described in the Cisco 7600 series router publications:
–
Configuration Fundamentals Configuration Guide
–
Configuration Fundamentals Command Reference
–
Bridging and IBM Networking Configuration Guide
–
Bridging and IBM Networking Command Reference
–
Interface Configuration Guide
–
Interface Command Reference
–
Network Protocols Configuration Guide, Parts 1, 2, and 3
–
Network Protocols Command Reference, Parts 1, 2, and 3
–
Security Configuration Guide
–
Security Command Reference
–
Switching Services Configuration Guide
–
Switching Services Command Reference
–
Voice, Video, and Home Applications Configuration Guide
–
Voice, Video, and Home Applications Command Reference
–
Software Command Summary
–
Software System Error Messages
–
Debug Command Reference
–
Internetwork Design Guide
–
Internetwork Troubleshooting Guide
–
Configuration Builder Getting Started Guide
The Cisco IOS Configuration Guides and Command References are located at this URL:
http://www.cisco.com/univercd/cc/td/doc/product/software/ios122/index.htm
•
For information about MIBs, go to this URL:
http://www.cisco.com/public/sw-center/netmgmt/cmtk/mibs.shtmlObtaining Documentation
Cisco documentation and additional literature are available on Cisco.com. This section explains the product documentation resources that Cisco offers.
Cisco.com
You can access the most current Cisco documentation at this URL:
http://www.cisco.com/techsupport
You can access the Cisco website at this URL:
You can access international Cisco websites at this URL:
http://www.cisco.com/public/countries_languages.shtml
Product Documentation DVD
The Product Documentation DVD is a library of technical product documentation on a portable medium. The DVD enables you to access installation, configuration, and command guides for Cisco hardware and software products. With the DVD, you have access to the HTML documentation and some of the PDF files found on the Cisco website at this URL:
http://www.cisco.com/univercd/home/home.htm
The Product Documentation DVD is created and released regularly. DVDs are available singly or by subscription. Registered Cisco.com users can order a Product Documentation DVD (product number DOC-DOCDVD= or DOC-DOCDVD=SUB) from Cisco Marketplace at the Product Documentation Store at this URL:
http://www.cisco.com/go/marketplace/docstore
Ordering Documentation
You must be a registered Cisco.com user to access Cisco Marketplace. Registered users may order Cisco documentation at the Product Documentation Store at this URL:
http://www.cisco.com/go/marketplace/docstore
If you do not have a user ID or password, you can register at this URL:
http://tools.cisco.com/RPF/register/register.do
Documentation Feedback
You can provide feedback about Cisco technical documentation on the Cisco Support site area by entering your comments in the feedback form available in every online document.
Cisco Product Security Overview
Cisco provides a free online Security Vulnerability Policy portal at this URL:
http://www.cisco.com/en/US/products/products_security_vulnerability_policy.html
From this site, you will find information about how to do the following:
•
Report security vulnerabilities in Cisco products
•
Obtain assistance with security incidents that involve Cisco products
•
Register to receive security information from Cisco
A current list of security advisories, security notices, and security responses for Cisco products is available at this URL:
To see security advisories, security notices, and security responses as they are updated in real time, you can subscribe to the Product Security Incident Response Team Really Simple Syndication (PSIRT RSS) feed. Information about how to subscribe to the PSIRT RSS feed is found at this URL:
http://www.cisco.com/en/US/products/products_psirt_rss_feed.html
Reporting Security Problems in Cisco Products
Cisco is committed to delivering secure products. We test our products internally before we release them, and we strive to correct all vulnerabilities quickly. If you think that you have identified a vulnerability in a Cisco product, contact PSIRT:
•
For emergencies only — security-alert@cisco.com
An emergency is either a condition in which a system is under active attack or a condition for which a severe and urgent security vulnerability should be reported. All other conditions are considered nonemergencies.
•
For nonemergencies — psirt@cisco.com
In an emergency, you can also reach PSIRT by telephone:
•
1 877 228-7302
•
1 408 525-6532
Tip
We encourage you to use Pretty Good Privacy (PGP) or a compatible product (for example, GnuPG) to encrypt any sensitive information that you send to Cisco. PSIRT can work with information that has been encrypted with PGP versions 2.x through 9.x.
Never use a revoked encryption key or an expired encryption key. The correct public key to use in your correspondence with PSIRT is the one linked in the Contact Summary section of the Security Vulnerability Policy page at this URL:
http://www.cisco.com/en/US/products/products_security_vulnerability_policy.html
The link on this page has the current PGP key ID in use.
If you do not have or use PGP, contact PSIRT to find other means of encrypting the data before sending any sensitive material.
Product Alerts and Field Notices
Modifications to or updates about Cisco products are announced in Cisco Product Alerts and Cisco Field Notices. You can receive these announcements by using the Product Alert Tool on Cisco.com. This tool enables you to create a profile and choose those products for which you want to receive information.
To access the Product Alert Tool, you must be a registered Cisco.com user. Registered users can access the tool at this URL:
http://tools.cisco.com/Support/PAT/do/ViewMyProfiles.do?local=en
To register as a Cisco.com user, go to this URL:
http://tools.cisco.com/RPF/register/register.do
Obtaining Technical Assistance
Cisco Technical Support provides 24-hour-a-day award-winning technical assistance. The Cisco Support website on Cisco.com features extensive online support resources. In addition, if you have a valid Cisco service contract, Cisco Technical Assistance Center (TAC) engineers provide telephone support. If you do not have a valid Cisco service contract, contact your reseller.
Cisco Support Website
The Cisco Support website provides online documents and tools for troubleshooting and resolving technical issues with Cisco products and technologies. The website is available 24 hours a day at this URL:
http://www.cisco.com/en/US/support/index.html
Access to all tools on the Cisco Support website requires a Cisco.com user ID and password. If you have a valid service contract but do not have a user ID or password, you can register at this URL:
http://tools.cisco.com/RPF/register/register.do
Note
Before you submit a request for service online or by phone, use the Cisco Product Identification Tool to locate your product serial number. You can access this tool from the Cisco Support website by clicking the Get Tools & Resources link, clicking the All Tools (A-Z) tab, and then choosing Cisco Product Identification Tool from the alphabetical list. This tool offers three search options: by product ID or model name; by tree view; or, for certain products, by copying and pasting show command output. Search results show an illustration of your product with the serial number label location highlighted. Locate the serial number label on your product and record the information before placing a service call.
Tip
Displaying and Searching on Cisco.com
If you suspect that the browser is not refreshing a web page, force the browser to update the web page by holding down the Ctrl key while pressing F5.
To find technical information, narrow your search to look in technical documentation, not the entire Cisco.com website. After using the Search box on the Cisco.com home page, click the Advanced Search link next to the Search box on the resulting page and then click the Technical Support & Documentation radio button.
To provide feedback about the Cisco.com website or a particular technical document, click Contacts & Feedback at the top of any Cisco.com web page.Submitting a Service Request
Using the online TAC Service Request Tool is the fastest way to open S3 and S4 service requests. (S3 and S4 service requests are those in which your network is minimally impaired or for which you require product information.) After you describe your situation, the TAC Service Request Tool provides recommended solutions. If your issue is not resolved using the recommended resources, your service request is assigned to a Cisco engineer. The TAC Service Request Tool is located at this URL:
http://www.cisco.com/techsupport/servicerequest
For S1 or S2 service requests, or if you do not have Internet access, contact the Cisco TAC by telephone. (S1 or S2 service requests are those in which your production network is down or severely degraded.) Cisco engineers are assigned immediately to S1 and S2 service requests to help keep your business operations running smoothly.
To open a service request by telephone, use one of the following numbers:
Asia-Pacific: +61 2 8446 7411
Australia: 1 800 805 227
EMEA: +32 2 704 55 55
USA: 1 800 553 2447For a complete list of Cisco TAC contacts, go to this URL:
http://www.cisco.com/techsupport/contacts
Definitions of Service Request Severity
To ensure that all service requests are reported in a standard format, Cisco has established severity definitions.
Severity 1 (S1)—An existing network is "down" or there is a critical impact to your business operations. You and Cisco will commit all necessary resources around the clock to resolve the situation.
Severity 2 (S2)—Operation of an existing network is severely degraded, or significant aspects of your business operations are negatively affected by inadequate performance of Cisco products. You and Cisco will commit full-time resources during normal business hours to resolve the situation.
Severity 3 (S3)—Operational performance of the network is impaired while most business operations remain functional. You and Cisco will commit resources during normal business hours to restore service to satisfactory levels.
Severity 4 (S4)—You require information or assistance with Cisco product capabilities, installation, or configuration. There is little or no effect on your business operations.
Obtaining Additional Publications and Information
Information about Cisco products, technologies, and network solutions is available from various online and printed sources.
•
The Cisco Online Subscription Center is the website where you can sign up for a variety of Cisco e-mail newsletters and other communications. Create a profile and then select the subscriptions that you would like to receive. To visit the Cisco Online Subscription Center, go to this URL:
http://www.cisco.com/offer/subscribe
•
The Cisco Product Quick Reference Guide is a handy, compact reference tool that includes brief product overviews, key features, sample part numbers, and abbreviated technical specifications for many Cisco products that are sold through channel partners. It is updated twice a year and includes the latest Cisco channel product offerings. To order and find out more about the Cisco Product Quick Reference Guide, go to this URL:
•
Cisco Marketplace provides a variety of Cisco books, reference guides, documentation, and logo merchandise. Visit Cisco Marketplace, the company store, at this URL:
http://www.cisco.com/go/marketplace/
•
Cisco Press publishes a wide range of general networking, training, and certification titles. Both new and experienced users will benefit from these publications. For current Cisco Press titles and other information, go to Cisco Press at this URL:
•
Internet Protocol Journal is a quarterly journal published by Cisco for engineering professionals involved in designing, developing, and operating public and private internets and intranets. You can access the Internet Protocol Journal at this URL:
•
Networking products offered by Cisco, as well as customer support services, can be obtained at this URL:
http://www.cisco.com/en/US/products/index.html
•
Networking Professionals Connection is an interactive website where networking professionals share questions, suggestions, and information about networking products and technologies with Cisco experts and other networking professionals. Join a discussion at this URL:
http://www.cisco.com/discuss/networking
•
"What's New in Cisco Documentation" is an online publication that provides information about the latest documentation releases for Cisco products. Updated monthly, this online publication is organized by product category to direct you quickly to the documentation for your products. You can view the latest release of "What's New in Cisco Documentation" at this URL:
http://www.cisco.com/univercd/cc/td/doc/abtunicd/136957.htm
•
World-class networking training is available from Cisco. You can view current offerings at this URL:
Posted: Thu Feb 14 13:08:06 PST 2008
All contents are Copyright © 1992--2008 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.