Command Summary for the MSC


Command Summary for the MSC


Table 4-1 provides an alphabetical list of some of the related commands to configure, monitor, and maintain MSCs on the Cisco 7304 router. For more information about the commands, see Chapter 18, "Command Reference" in this book and the Cisco IOS Release 12.2 command reference and master index publications.


Caution The debug hw-module subslot, debug tcam_mgr, test hw-module subslot, and test tcam-mgr subslot commands are not intended for production use and should be used only under the supervision of Cisco Systems technical support personnel. The test commands can produce unexpected operation of your SPA. For more information, see Chapter 18, "Command Reference."

Table 4-1 Command Summary 

Command
Purpose

Router# debug hw-module subslot slot/subslot {all | driver | fpga | if | mac | phy | tcam | force-intr}

Debugs a SPA and all of its interfaces.

Router# debug tcam_mgr {error | event | profile}

Debugs the TCAM manager.

Router# hw-module slot slot-number {start | stop}

Deactivates or reactivates a line card or MSC, and any installed SPAs in that MSC.

Router# hw-module subslot slot/subslot {start | stop}

Deactivates or reactivates a SPA and all of its interfaces.

Router# show c7300

Displays the types and status of cards (NSEs, line cards, MSCs, and SPAs) installed in a Cisco 7300 series router.

Router# show diag [slot-number | chassis | {subslot slot/subslot}]

Displays all hardware and diagnostic information for a line card, NSE, chassis, MSC, or SPA including IDPROM and FPGA version information.

Router# show environment [all | last | table]

Displays power supply, fan, voltage, and temperature information for the router.

Router# show hw-module subslot slot/subslot {brief | config | counters | errors | registers | status} {fpga | mac | phy | spi4} port

Displays diagnostic information about internal hardware devices for a SPA.

Router# show tcam-mgr subslot slot/subslot inst-info

Router# show tcam-mgr subslot slot/subslot region region-number [config | statistics]

Router# show tcam-mgr subslot slot/subslot {rx-dest-mac | rx-vlan}{alloc-mbus [summary] | table}

Displays TCAM manager information for a SPA.

Router# test hw-module subslot slot/subslot c2w {read device-address port subaddress bytes | write device-address port subaddress bytes}

Tests the Cisco 2 wire (c2w) device on a SPA.

Router# test hw-module subslot slot/subslot failed failure-code

Sends a failed event on a SPA.

Router# test hw-module subslot slot/subslot mac config port {1000mbps-gmii | 1000mbps-rgmii | 100mbps | 10mbps} {full | half} {copper | fiber}

Router# test hw-module subslot slot/subslot mac crc port {enable | disable}

Router# test hw-module subslot slot/subslot mac loopback port {line | none | spi3}

Tests the MAC device on a SPA.

Router# test hw-module subslot slot/subslot mdio {read phy-number phy-register-address | write phy-number phy-register-address}

Reads or writes to the PHY device registers through the MAC MII data input/output (MDIO) interface on a SPA.

Router# test hw-module subslot slot/subslot pause port {disable | enable | set { threshold {fpga fpga-pause-threshold-value | mac mac-pause-threshold-value } timer pause-timer-value}}

Enables, disables, and sets the pause frame-related configurations on a SPA.

Router# test hw-module subslot slot/subslot phy config port {copper | fiber} {1000mbps | 100mbps | 10mbps | auto} {auto | full | half} {autoneg | force}

Router# test hw-module subslot slot/subslot phy crossover port {auto | mdi | mdix}

Router# test hw-module subslot slot/subslot phy loopback port {internal | line | none}

Tests the physical interface (PHY) device on a SPA.

Router# test hw-module subslot slot/subslot policyram {read ram-virtual-address | write {ram-data | [{deny | permit} [tunnel [ignoreda]}

Tests the policy table used by the Field Programmable Gate Array (FPGA) device for ternary content addressable memory (TCAM) lookup on a SPA.

Router# test hw-module subslot slot/subslot tcam insert port {dmac addr hex-mac-address mask hex-mask | vlan vlan-id} {deny | permit}

Router# test hw-module subslot slot/subslot tcam lookup port {dmac addr hex-mac-address mask hex-mask | vlan vlan-id}

Router# test hw-module subslot slot/subslot tcam read tcam-virtual-address

Router# test hw-module subslot slot/subslot tcam remove {dmac addr hex-mac-address mask hex-mask | vlan vlan-id}

Router# test hw-module subslot slot/subslot tcam write {mask |value} tcam-virtual-address port lookup-type {dmac hex-mac-address | vlan vlan-id}

Tests the ternary content addressable memory (TCAM) device on a SPA.

Router# test hw-module subslot slot/subslot temperature sensor-number

Tests a temperature sensor on a SPA.

Router# test tcam-mgr subslot slot/subslot {delete | empty | fill}{rx-dest-mac | rx-vlan} value

Router# test tcam-mgr subslot slot/subslot insert [bottom | top]{rx-dest-mac | rx-vlan} value

Router# test tcam-mgr subslot slot/subslot fulltcam {off | on}

Router# test tcam-mgr subslot slot/subslot off

Router# test tcam-mgr subslot slot/subslot read mc-index value vc-index value

Tests the TCAM manager for a SPA.