Table A-1gives a detailed description of the workgroup CDDI/FDDI EISA HP adapter specifcations.
Single Attachment FDDI EISA HP Adapter | Single Attachment CDDI EISA HP Adapter | |
---|---|---|
Physical dimensions: | ||
Height Depth Width Weight | 4.5" (11.4 cm) 10.3" (26.2 cm) 0.75" (1.9 cm) 9 oz. (255 g) | 4.5" (11.4 cm) 10.3" (26.2 cm) 0.75" (1.9 cm) 9.5 oz. (270 g) |
Power requirements | +5V @ 2A (maximum) +12V @ 150 mA (maximum) | +5V @ 1.8A (maximum) +12V @ 150 mA (maximum) |
Thermal dissipation | 9.3 watts (maximum) | 8.3 watts (maximum) |
Environmental conditions: | ||
Operating temperature Storage temperature Relative humidity | 32 to 104ºF (0 to 40ºC) -40 to 167ºF (-40 to 75ºC) 10 to 90% (non-condensing) | 32 to 104ºF (0 to 40ºC) -40 to 167ºF (-40 to 75ºC) 10 to 90% (non-condensing) |
EMI certifications | FCC Class A (47 CFR, Part 15), CE Mark, and VCCI Class 2 | FCC Class A (47 CFR, Part 15), CE Mark, and VCCI Class 2 |
Network connector | MIC | RJ-45 |
Station-to-station cabling | Up to 2 kilometers of either 62.5/125-micron or 50/125-micron multimode fiber | Category 5 UTP: up to 100 meters IBM Type 1 STP: up to 100 meters |
Faceplate indicators | Status, ringop | Status, ringop |
EISA compliance | EISA specification 3.12 | EISA specification 3.12 |
Dual Attachment FDDI EISA HP Adapter | Dual Attachment CDDI EISA HP Adapter | |
---|---|---|
Physical dimensions: | ||
Height Depth Width Weight | 4.4" (11.4 cm) 13.25" (33.6 cm) 0.75" (1.9 cm) 9 oz. (255 g) | 4.4" (11.4 cm) 13.25" (33.6 cm) 0.75" (1.9 cm) 9.5 oz. (270 g) |
Power requirements | +5V @ 2A (maximum) | +5V @ 550 mA (maximum) +12V @ 60 mA (maximum) |
Thermal dissipation | 9.3 watts (maximum) | 8.3 watts (maximum) |
Environmental conditions: | ||
Operating temperature Storage temperature Relative humidity | 32 to 104ºF (0 to 40ºC) -40 to 167ºF (-40 to 75ºC) 10 to 90% (non-condensing) | 32 to 104ºF (0 to 40ºC) -40 to 167ºF (-40 to 75ºC) 10 to 90% (non-condensing) |
EMI certifications | FCC Class A (47 CFR, Part 15), CE Mark, and VCCI Class 2 | FCC Class A (47 CFR, Part 15), CE Mark, and VCCI Class 2 |
Network connector | MIC | RJ-45 |
Faceplate indicators | Status, ringop | Status, ringop |
EISA compliance | EISA Specification 3.12 | EISA Specification 3.12 |
|