cc/td/doc/product/cable/vod/umg9820
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table Of Contents

Cisco uMG9820 Technical Specifications


Cisco uMG9820 Technical Specifications


Table A-1 lists the technical specifications for the Cisco uMG9820.

Table A-1 Technical Specifications for the Cisco uMG9820  

Characteristic
Value
Physical
Dimensions

1.72 in. high x 18.98 in. wide x 21.41 in. deep (43.7 x 444.5 x 342.9 mm)

Mounting standard

1 RU, 19 in.

Weight

17.9 lbs (8.1 kg) typical (fully loaded)

Electrical
Input voltage

100-240 VAC

Input frequency

50-60 Hz

Input current

3 A max. at 100 VAC input

AC power connector

IEC 320 standard 6.3-A power entry module, RFI filtered, with metric fuse holder

Standards
EMI standards

CFR47: 2000, FCC Part 15, Subpart B for Class A

Industry Canada ICES-003 for Class A

Safety standards

CAN/CSA-C22.2 No. 60950-00, UL 60950

Agency approvals

Refer to Cisco uMG9820 QAM Gateway Regulatory Compliance and Safety Information

Environmental
Temperature

Operating: 40-104ЧF (10-40ЧC)

Nonoperating: -40-158ЧF (-40-70ЧC)

Humidity (relative, noncondensing)

Operating: 20 to 90%

Nonoperating: 5 to 95%

Altitude

Operating: sea level to 6562 ft (2000 M)

Nonoperating: sea level to 15,748 ft (4800 M)

 
   
   
   
Inputs
Input interface

Redundant 1+1 port configuration

SFP module connectors

LAN protocol

IEEE 802.3z

Data rate per port

1000 Mbps

Data format

UDP datagram encapsulation of MPEG-2 SPTS

Maximum of 256 MPEG-2 SPTS encapsulated in UDP/IP

Up to six PIDs per program (including ECM PID)

Up to seven 188-byte MPEG-2 packets per UDP datagram

3-4 Mbps per SPTS (nominal)

Processing features
Function capability

PID remapping

PID filtering

MPEG-remultiplexing

PCR restamping

MPEG-2 PSI extraction, generation, and insertion

Input network jitter buffer (user-settable latency; max. 70 milliseconds)

Network management
Management connectors

RJ-45: 10BASE-T/100BASE-TX Ethernet for network management system (NMS)

RJ-45: 10BASE-T/100BASE-TX Ethernet for conditional access system (CAS)

EIA-232

Management protocols

BootP, DHCP

SNMP v1, v2c

TFTP

Telnet

Command-line interface (CLI)

RF output specifications
Modulation format

256QAM (64QAM not available in initial releases)

Framing structure, channel coding, modulation

Per ITU-T Recommendation J.83 Annex B

Output interface

F-connector (75-ohm impedance, nominal)

Monitor interface

MCX connector (50-ohm impedance, nominal)

Center frequency

225-900 MHz

Frequency step size

12.5 kHz

Frequency response

256QAM: 12% square-root raised-cosine shaping

64QAM: 18% square-root raised-cosine shaping (64QAM not available in initial releases)

Any 5-MHz band: +/- 0.25 dB

Any 7-MHz band: +/- 0.4 dB

Frequency accuracy over time/temperature

+/- 20 kHz

Channel-to-channel level accuracy

+/- 0.7 dB

Group delay

Any 5-MHz band: 8 nsec p-p max.

Output levels

Total average block1 power: 60 dBmV

Step size: 0.1 dB (typical)

Max. attenuated2 block power: 50 dBmV

Per-channel power: 57 dBmV

Gain control range

50-60 dBmV block power

Return loss

Inband: > 14 dB; 13 dB above 750 MHz

Spurious emissions and noise

In-channel, at max. power, center frequency +/- 3 MHz: < -48 dBc

Broadband (50-860 MHz): < -60 dBc (with respect to total block power, including harmonics)

Isolation

RF chain to RF chain: < 50 dBc

Noise (phase)
(standard 6-MHz CATV channels, double sideband)

1-10 kHz: < -40 dBc (< -50 dBc typical)

10-50 kHz: < -40 dBc (< -50 dBc typical)

50 kHz-3 MHz: < -51 dBc (< -55 dBc typical)

Noise (broadband)

< -9 dBmV (block power at 60 dBmV, plus average noise from all channels outside +/- 24 MHz from the band edges)

Noise (modulated adjacent)
(2x dual-block channel-output version)

+/- 3-3.75 MHz: < -58 dBc (-61 dBc typical)

+/- 3-3.75 MHz: < -59 dBc (-61 dBc typical)

+/- 9-15 MHz: < -60.5 dBc (-63 dBc typical)

1 A "block" represents the entire RF signal (12 MHz) from each QAM port. The signal consists of two adjacent 6-MHz-wide QAM channels.

2 An attenuator on the RF output provides up to 10 dB of attenuation (see "Gain Control Range," above).



hometocprevnextglossaryfeedbacksearchhelp

Posted: Thu Oct 7 15:58:22 PDT 2004
All contents are Copyright © 1992--2004 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.