Table B-1 Trap Descriptions
Trap
|
Description
|
SNMPv2-MIB:coldStart
|
An alarm with a severity of "minor" is generated against the uBR when a cold start occurs.
|
SNMPv2-MIB:warmStart
|
Description: An alarm with a severity of "minor" is generated against the uBR when a warm start occurs.
|
SNMPv2-MIB:linkDown [interface, port objects]
|
An alarm with a severity of "major" is generated against the uBR when the interface is down.
|
SNMPv2-MIB:linkUp [interface, port objects]
|
An alarm with a severity of "normal" is generated against the uBR when the interface is up.
|
SNMPv2-MIB:authenticationFailure
|
An alarm with a severity of "warning" is generated against the uBR upon SNMP authentication failure.
|
SNMPv2-MIB:egpNeighborLoss
|
An alarm with a severity of "warning" is generated against the uBR when there is an egp neighbor loss.
|
CISCO-DOCS-EXT-MIB: cdxCmtsCmOnOffNotification
|
An alarm with a severity of "critical" is generated when a cable modem becomes offline, and an alarm with a severity of "normal" is generated when a cable modem comes online.
|
CISCO-SYSLOG-MIB: clogMessageGenerated
|
An alarm with a severity of "informational" is generated when the CMTS CM Poller finishes polling for the current cycle.
|
CISCO-CONFIG-MAN-MIB: ciscoConfigManEvent
|
An alarm with a severity of "informational" is generated as notification of a configuration management event as recorded in the ccmHistoryEventTable.
|
ENTITY-MIB. my:entConfigChange
|
An alarm with a severity of "informational" is generated when the value of entLastChangeTime changes.
|
CISCO-ENVMON-MIB: ciscoEnvMonShutdownNotification
|
An alarm with a severity of "critical" is generated if the environmental monitor detects that a testpoint is reaching a critical state and is about to initiate a shutdown.
|
CISCO-ENVMON-MIB: ciscoEnvMonVoltageNotification
|
An alarm with a severity of "critical" is generated if the voltage measured at a given testpoint is outside the normal range for the testpoint (at the warning, critical, or shutdown stage).
|
CISCO-ENVMON-MIB: ciscoEnvMonTemperatureNotification
|
An alarm with a severity of "critical" is generated if the temperature measured at a given testpoint is outside the normal range for the testpoint (at the warning, critical, or shutdown stage).
|
CISCO-ENVMON-MIB: ciscoEnvMonFanNotification
|
An alarm with a severity of "critical" is generated if any one of the fans in the fan array (where it exists) fails.
|
CISCO-ENVMON-MIB: ciscoEnvMonRedundantSupplyNotification
|
An alarm with a severity of "critical" is generated if the redundant power supply (where one exists) fails.
|
CISCO-FLASH-MIB: ciscoFlashCopyCompletionTrap
|
An alarm with a severity of "informational" is generated upon completion of a flash copy operation if such a trap was requested when the operation was initiated.
|
CISCO-FLASH-MIB: ciscoFlashPartitioningCompletionTrap
|
An alarm with a severity of "informational" is generated upon completion of a partitioning operation if such a trap was requested when the operation was initiated.
|
CISCO-FLASH-MIB: ciscoFlashMiscOpCompletionTrap
|
An alarm with a severity of "informational" is generated upon completion of a miscellaneous flash operation (enumerated in ciscoFlashMiscOpCommand) if such a trap was requested when the operation was initiated.
|
CISCO-FLASH-MIB: ciscoFlashDeviceChangeTrap
|
An alarm with a severity of "informational" is generated whenever removable Flash device is inserted or removed.
|