Table B-1 shows the traps supported for Cisco uBR7200 series universal broadband router and cable modem management.

Table B-1 Trap Descriptions 

Trap
Description

SNMPv2-MIB:coldStart

An alarm with a severity of "minor" is generated against the uBR when a cold start occurs.

SNMPv2-MIB:warmStart

Description: An alarm with a severity of "minor" is generated against the uBR when a warm start occurs.

SNMPv2-MIB:linkDown [interface, port objects]

An alarm with a severity of "major" is generated against the uBR when the interface is down.

SNMPv2-MIB:linkUp [interface, port objects]

An alarm with a severity of "normal" is generated against the uBR when the interface is up.

SNMPv2-MIB:authenticationFailure

An alarm with a severity of "warning" is generated against the uBR upon SNMP authentication failure.

SNMPv2-MIB:egpNeighborLoss

An alarm with a severity of "warning" is generated against the uBR when there is an egp neighbor loss.

CISCO-DOCS-EXT-MIB:
cdxCmtsCmOnOffNotification

An alarm with a severity of "critical" is generated when a cable modem becomes offline, and an alarm with a severity of "normal" is generated when a cable modem comes online.

CISCO-SYSLOG-MIB:
clogMessageGenerated

An alarm with a severity of "informational" is generated when the CMTS CM Poller finishes polling for the current cycle.

CISCO-CONFIG-MAN-MIB:
ciscoConfigManEvent

An alarm with a severity of "informational" is generated as notification of a configuration management event as recorded in the ccmHistoryEventTable.

ENTITY-MIB.
my:entConfigChange

An alarm with a severity of "informational" is generated when the value of entLastChangeTime changes.

CISCO-ENVMON-MIB:
ciscoEnvMonShutdownNotification

An alarm with a severity of "critical" is generated if the environmental monitor detects that a testpoint is reaching a critical state and is about to initiate a shutdown.

CISCO-ENVMON-MIB:
ciscoEnvMonVoltageNotification

An alarm with a severity of "critical" is generated if the voltage measured at a given testpoint is outside the normal range for the testpoint (at the warning, critical, or shutdown stage).

CISCO-ENVMON-MIB:
ciscoEnvMonTemperatureNotification

An alarm with a severity of "critical" is generated if the temperature measured at a given testpoint is outside the normal range for the testpoint (at the warning, critical, or shutdown stage).

CISCO-ENVMON-MIB:
ciscoEnvMonFanNotification

An alarm with a severity of "critical" is generated if any one of the fans in the fan array (where it exists) fails.

CISCO-ENVMON-MIB:
ciscoEnvMonRedundantSupplyNotification

An alarm with a severity of "critical" is generated if the redundant power supply (where one exists) fails.

CISCO-FLASH-MIB:
ciscoFlashCopyCompletionTrap

An alarm with a severity of "informational" is generated upon completion of a flash copy operation if such a trap was requested when the operation was initiated.

CISCO-FLASH-MIB:
ciscoFlashPartitioningCompletionTrap

An alarm with a severity of "informational" is generated upon completion of a partitioning operation if such a trap was requested when the operation was initiated.

CISCO-FLASH-MIB:
ciscoFlashMiscOpCompletionTrap

An alarm with a severity of "informational" is generated upon completion of a miscellaneous flash operation (enumerated in ciscoFlashMiscOpCommand) if such a trap was requested when the operation was initiated.

CISCO-FLASH-MIB:
ciscoFlashDeviceChangeTrap

An alarm with a severity of "informational" is generated whenever removable Flash device is inserted or removed.