H Commands
hw-module

H Commands


The commands shown in this chapter apply to the Catalyst 8540 MSR, Catalyst 8510 MSR, and LightStream 1010 ATM switch routers. Where an entire command or certain attributes of a command have values specific to a particular switch or switch router, an exception is indicated by the following callouts:

Refer to Appendix D of this command reference for a detailed list of commands that have been removed, changed or replaced.

hw-module

To reset a specific port adapter, use the hw-module EXEC command.

hw-module {slot number | subslot subslot/subcard} reset

Syntax Description

slot number

Physical slot number of the port adapter you want to reset.

subslot subslot/ subcard

Indicates either a half-width card or daughter card attached to full-width cards. If the subcard is not specified, in the case of a half-width card, both the cards in the slot are reset. In case of full-width cards, the motherboard in the slot is reset.

reset

Reset is performed on the hardware module selected using slot or subslot options.

Defaults

None

Command Modes

EXEC

Command History

Release  Modification 

12.0(1a)W5(5b)

New command

Usage Guidelines

If the subcard is not provided, both subcards in the slot are reset. In the case of a full-width card, the motherboard in the selected slot is reset. The subcard argument indicates a specific subcard in a selected slot. If the subcard is not given, the full-width card in the selected slot is reset.

This command is available to reset port adapters only. The hw-module command cannot be used to reset route processor controllers and switch controllers.


Caution   If any active connections are configured on this port, they will be lost until the port adapter restarts. The running configuration is restored only when the port adapter returns to normal operation.

Examples

The following example resets the port adapter in slot 3.

Switch# hw-module slot 3 reset

Related Commands

Command  Description 