|
Table Of Contents
Determining Your Software Release
Release Names, Versions, and Part Numbers
New Features in Release 12.0(28)W5(30a)
New Features in Release 12.0(28)W5(30)
New Features in Release 12.0(27)W5(29)
New Features in Release 12.0(26)W5(28)
New Features in Release 12.0(24)W5(26c)
New Features in Release 12.0(24)W5(26b)
New Features in Release 12.0(24)W5(26)
New Features in Release 12.0(22)W5(25)
New Features in Release 12.0(20)W5(24b)
New Features in Release 12.0(20)W5(24a)
New Features in Release 12.0(20)W5(24)
New Features in Release 12.0(19)W5(23)
New Features in Release 12.0(18)W5(22)
New Features in Release 12.0(16)W5(21)
New Features in Release 12.0(13)W5(19c)
New Features in Release 12.0(10)W5(18b)
New Features in Release 12.0(7)W5(15c)
New Features in Release 12.0(5)W5(13d)
New Features in Release 12.0(4a)W5(11a)
New Features in Release 12.0(1a)W5(9)
New Features in Release 12.0(1a)W5(6f)
Caveat Symptoms and Workaround
Obtaining Technical Assistance
Cisco Technical Support Website
Definitions of Service Request Severity
Obtaining Additional Publications and Information
Release Notes for the Catalyst 8510 and LightStream 1010 ATM Switch for Cisco IOS Release 12.0(28)W5(30a)
May 31, 2004
Catalyst 8510 and LightStream 1010 ATM Switch Cisco for IOS Release 12.0(28)W5(30a)
Text Part Number: OL-5989-01 Rev. A0
This document describes the features and caveats for Cisco IOS Release 12.0(28)W5(30a) for the Catalyst 8510 and LightStream 1010 ATM switch.
Note All information pertains to both the Catalyst 8510 and LightStream 1010 ATM switch platforms, unless differences between the platforms are noted in the text.
Contents
This document includes the following sections:
• Caveats
• Caveat Symptoms and Workaround
• Obtaining Technical Assistance
• Obtaining Additional Publications and Information
Introduction
The Catalyst 8510 and LightStream 1010 ATM switch provide switched ATM connections to individual workstations, servers, LAN segments, or other ATM switches and routers using fiber-optic, unshielded twisted-pair (UTP), and coaxial cable.
The Catalyst 8510 CSR belongs to a class of high-performance Layer 3 switch routers. It is optimized for the campus LAN or intranet and provide both wirespeed Ethernet routing and switching services.
Note The ATM switch processors (hardware version 4.0 or higher) and all port adapters can be installed in the Catalyst 5500 switch chassis.
System Requirements
This section describes the system requirements for Cisco IOS Release 12.0 and includes the following sections:
• Determining Your Software Release
• Release Names, Versions, and Part Numbers
Memory Requirements
Catalyst 8510 MSR and LightStream 1010
The DRAM memory configuration is 64-MB DRAM (MEM-ASP64M), which is the default for both the Catalyst 8510 and the LightStream 1010 ATM switch platforms.
Catalyst 8510 CSR
Table 1 lists the default Flash and DRAM memory for the Catalyst 8510 CSR, as well as memory upgrade options.
Table 1 Catalyst 8500 CSR Default Memory and Upgrade Options
Memory Type Catalyst 8510 CSR Defaults Upgrade OptionsFlash memory
16 MB
MEM-ASP-FLC16M=
MEM-ASP-FLC20M=DRAM
64 MB
None
To download and store a copy of the Catalyst 8510 CSR software image, we recommend using a minimum 20 MB Flash PC Card, which will allow you to have two or more images installed at the same time.
The Catalyst 8510 CSR boots from its onboard Flash memory by default. To change this default to boot from a Flash PC Card instead, you must change the configuration register setting to 0x2102. Refer to the Layer 3 Switching Software Feature and Configuration Guide for more information.
Hardware Supported
Table 2 lists the interfaces supported by both the Catalyst 8510 MSR and LightStream 1010 ATM switch and their minimum software release requirements. All platform specific requirements are noted in the table. Table 3 lists this information for the Catalyst 8510 CSR.
Note Although minimum software versions are listed, we strongly recommend that you use the latest available software release for all Catalyst 8510 and LightStream 1010 hardware.
Table 2 Catalyst 8510 MSR and LightStream 1010 Interface Modules and Minimum Software Required
Part Number Description Minimum Software Version RequiredWAI-OC3-4MM
4-port STS-3c/STM-1 multimode fiber port adapters
WAS1-1
WAI-OC3-4SS
4-port STS-3c/STM-1 single-mode fiber port adapters
WAS1-1
WAI-OC3-4U5
4-port STS-3c/STM-1 UTP-5 port adapters
WAS1-1
WAI-OC3-4SSLR
4-port STS-3c/STM-1 SMF long reach port adapters
WAS3-2
WAI-OC3-1S3M
OC-3 mix port adapter module, 1 IR+ port and 3 MM ports
WAS3-1
WAI-OC12-1MM
1-port STS-12c/STM-4c multimode fiber port adapters
WAS1-2
WAI-OC12-1SS
1-port STS-12c/STM-4c SMF port adapters
WAS1-1
WAI-OC12-1SSLR
1-port STS-12c/STM-4c SMF long reach port adapters
WAS3-2
WAI-ATM25-12P
12-port ATM 25 port adapters with 96-pin telco cable
WAS3-2
WAI-T3-2BNC
2-port DS-3 port adapters
WAS1-1
WAI-E3-2BNC
2-port E3 port adapters
WAS1-1
WAI-T3-4BNC
4-port DS-3 port adapters
WAS3-1
WAI-E3-4BNC
4-port E3 port adapters
WAS3-3
WAI-T1-4RJ48
4-port T1 (ATM) with RJ-48 interface port adapters
WAS3-1
WAI-E1-4RJ48
4-port E1 (ATM) with RJ-48 interface port adapters
WAS3-1
WAI-E1-4BNC
4-port E1 (ATM) with BNC interface port adapters
WAS3-1
WAI-T1C-4RJ48
4-port T1 (circuit emulation) with RJ-48 interface port adapters
WAS3-1
WAI-E1C-4RJ48
4-port E1 (circuit emulation) with RJ-48 interface port adapters
WAS3-1
WAI-E1C-4BNC
4-port E1 (circuit emulation) with BNC interface port adapters
WAS3-1
L1010-PWR-DC
Power supply DC
WAS3-1
L1010-ASP-B-FC1
WAS1-3
L1010-ASP-B-FCPFQ
WAS4-1
L1010-ASP-C-FC1
Hot-swappable ASP with FC-PCQ
W5-5
L1010-ASP-C-FCPFQ
Hot-swappable multiservice switch route processor
W5-5
C85MS-4E1-FRRJ48
4-port CE1 with RJ-48c interface Frame Relay port adapters
W5-5
WS-X5165
ATM-Fabric Integration Module for the Catalyst 5500
W5-5
C85MS-1DS3-FRBNC
1-port CDS3 Frame Relay port adapter
W5-9
C85MS-ATM25-4P
4-port 25-Mbps port adapter
W5-9
C85MS-8T1-IMA
8-port T1 port adapter with IMA4
Catalyst 8510:
S851R2-12.0.4WLightStream 1010:
SL10R2-12.0.4WC85MS-8E1-IMA-120
8-port E1 port adapter with IMA4
Catalyst 8510:
S851R2-12.0.4WLightStream 1010:
SL10R2-12.0.4WC8510-ARM-64K
ATM router module
S851R2-12.0.10W5
C8510-ACL
ACL6 daughter card
S851R2-12.0.10W5
C85GE-8X-64K=
8-port Gigabit Ethernet 64K
S851R2-12.0.10W5
C85GE-1X-16K=
1-port Gigabit Ethernet 16K
S851R2-12.0.10W5
C85GE-1X-64K=
1-port Gigabit Ethernet 64K
S851R2-12.0.10W5
C85FE-8T-16K=
8-port 10/100 Fast Ethernet with RJ-45 16K
S851R2-12.0.10W5
C85FE-8T-64K=
8-port 10/100 Fast Ethernet with RJ-45 64K
S851R2-12.0.10W5
C85FE-8F-16K=
8-port 10/100 Fast Ethernet with MT-RJ 16K
S851R2-12.0.10W5
C85FE-8F-64K=
8-port 10/100 Fast Ethernet with MT-RJ 64K
S851R2-12.0.10W5
1 ASP = ATM switch processor.
2 FC-PCQ = feature card per-class queuing.
3 FC-PFQ = feature card per-flow queuing.
4 IMA = inverse multiplexing over ATM.
5 The LightStream 1010 ATM switch requires the ASP-C with FC-PFQ to support the ATM router module.
6 ACL = access control list.
Determining Your Software Release
To determine the version of Cisco IOS software currently running on either the Catalyst 8510 or the LightStream 1010 ATM switch, log into the switch and enter the show version EXEC command. The following is sample output from the show version command. The version number is indicated on the second line:
Cisco Internetwork Operating System Software
IOS (tm) LS1010 W5-5 Software (LS1010-WP-M), Version 12.0(28)W5(30a)
Additional command output lines include more information, such as processor revision numbers, memory amounts, hardware IDs, and partition information.
Other Firmware Code
Some of the port adapters supported on the Catalyst 8510 and LightStream 1010 ATM switch have upgradable FPGA and functional images. The FPGA and functional images include caveat fixes, but in most cases, it is not necessary to upgrade. The release notes that describe the caveats from the functional images are available on the World Wide Web at the following URL:
http://www.cisco.com/univercd/cc/td/doc/product/l3sw/8540/rel_12_0/w5_6f/rel_note/fpga_rn/index.htm
For information describing the firmware update process, refer to the ATM Switch Router Software Configuration Guide.
Feature Set Tables
The Cisco IOS release software is packaged in feature sets (also called software images) depending on the platform. Each feature set contains a specific set of Cisco IOS features. Those features are listed by release number in the following tables:
• Table 4— Feature Sets Supported by the Catalyst 8510 MSR and LightStream 1010 ATM Switch
• Table 5— Feature Sets Supported by the Catalyst 8510 CSR Part 1—Releases 12.0(28)W5(30a) through 12.0(13)W5(20)
• Table 6— Feature Sets Supported by the Catalyst 8510 CSR Part 2—Releases 12.0(10)W5(19c) through 12.0(1a)W5(6f)
Note All Catalyst 8510 CSR features are also applicable to the Catalyst 8510 MSR.
Table 4 Feature Sets Supported by the Catalyst 8510 MSR and LightStream 1010 ATM Switch
Feature Set 12.0(28)W5(30a), 12.0(28)W5(30), 12.0(27)W5(29), 12.0(26)W5(28), 12.0(24)W5(26c), 12.0(24)W5(26b),and 12.0(24)W5(26) 12.0(20)W5(24b), 12.0(20)W5(24a), 12.0(20)W5(24), 12.0(19)W5(23), 12.0(18)W5(22), 12.0(16)W5(21),
and 12.0(13)W5(19c) 12.0
(10)
W5
(18b) 12.0
(7)
W5
(15c) 12.0
(4a)W5(
11a) 12.0
(1a)
W5
(9) 12.0
(1a)
W5
(5b) 11.3
(3a)
WA4
(6)Left-justified E.164 AFI support
X
X
x
x
x
x
x
x
SNMP1
X
X
x
x
x
x
x
x
Asynchronous support
X
X
x
x
x
x
x
x
X
X
x
x
x
x
x
x
IP4
X
X
x
x
x
x
x
x
NTP5
X
X
x
x
x
x
x
x
TACACS+6
X
X
x
x
x
x
x
x
Telnet
X
X
x
x
x
x
x
x
Point-to-point and point-to-multipoint permanent VCCs7 and VPCs8
X
X
x
x
x
x
x
x
Point-to-point and
point-to-multipoint switched
VCCs and VPCs (UNI 3.0)X
X
x
x
x
x
x
x
Point-to-point and point-to-multipoint switched VCCs and VPCs (UNI 3.1)
X
X
x
x
x
x
x
x
Point-to-point and point-to-multipoint switched VCCs and VPCs (UNI 4.0)
X
X
x
x
x
x
x
x
Multipoint-to-point UNI signaling
X
X
x
x
x
x
x
x
Soft VCCs and VPCs
X
X
x
x
x
x
x
x
VP tunneling
X
X
x
x
x
x
x
x
VPI/VCI range support in ILMI 4.0
X
X
x
x
x
x
x
x
PNNI hierarchy
X
X
x
x
x
x
x
x
ILMI version 4.0
X
X
x
x
x
x
x
x
IISP9
X
X
x
x
x
x
x
x
LANE10 client (LEC11 ) and LANE Services (LES12 /BUS13 /LECS14 ) on ASP15
X
X
x
x
x
x
x
x
Token Ring LANE services
X
X
x
x
x
x
x
x
ATM ARP16 server on ASP
X
X
x
x
x
x
x
x
ATM ARP client on ASP
X
X
x
x
x
x
x
x
ATM tag switch router (TSR)
X
X
x
x
x
x
x
x
Port snooping
X
X
x
x
x
x
x
x
OAM17 F4 and F5
X
X
x
x
x
x
x
x
E.164 address translation
X
X
x
x
x
x
x
x
E.164 autoconversion
X
X
x
x
x
x
x
x
Circuit emulation
X
X
x
x
x
x
x
x
ATM access lists
X
X
x
x
x
x
x
x
ATM accounting
X
X
x
x
x
x
x
x
ATM RMON18
X
X
x
x
x
x
x
x
Multiple, weighted, dynamic thresholds for selective packet marking and discard
X
X
x
x
x
x
x
x
Shaped VP tunnels for CBR traffic (FC-PFQ only)
X
X
x
x
x
x
x
x
Substitution of other service categories in shaped VP tunnels (FC-PFQ feature cards only)
X
X
x
x
x
x
x
x
Dual leaky bucket policing (FC-PFQ feature cards only)
X
X
x
x
x
x
x
x
Scheduler/Service Class/PVC configuration for FC-PFQ feature cards
X
X
x
x
x
x
x
x
Logical multicast support (up to 254 leaves per output port, per point-to-multipoint VC) (FC-PFQ feature cards only)
X
X
x
x
x
x
x
x
Network clocking enhancements for smooth switchover (FC-PFQ feature cards only)
X
X
x
x
x
x
x
x
Per-VC or per-VP nondisruptive snooping (FC-PFQ feature cards only)
X
X
x
x
x
x
x
x
Support for non-zero MCR19 on ABR connections (FC-PFQ feature cards only)
X
X
x
x
x
x
x
x
Access lists on ILMI registration
X
X
x
x
x
x
x
x
CUGs
X
X
x
x
x
x
x
x
ATM soft restart
X
X
x
x
x
x
x
x
ATM accounting enhancements
X
X
x
x
x
x
x
x
CISCO-SYSLOG-MIB support
X
X
x
x
x
x
x
x
CISCO-CONFIG-COPY-MIB support
X
X
x
x
x
x
x
x
Signaling diagnostics and MIB
X
X
x
x
x
x
x
x
Supplemental AToM MIB
X
X
x
x
x
x
x
x
E1 Frame Relay Port Adapter
X
X
x
x
x
x
x
Frame Relay to ATM Interworking Features on the Channelized E1 Port Adapter
X
X
x
x
x
x
x
Hierarchical VP Tunnels
X
X
x
x
x
x
x
Remote logging for accounting
X
X
x
x
x
x
x
Tag Switching VC-Merge on Non-UBR VP Tunnels and Hierarchical VP Tunnels
X
X
x
x
x
x
x
PNNI Complex Node Representation
X
X
x
x
x
x
x
Support for ATM-Fabric Integration Module in Catalyst 5500
X
X
x
x
x
x
x
PNNI explicit paths
X
X
x
x
x
x
PNNI alternate link selection
X
X
x
x
x
x
Tag switching CoS
X
X
x
x
x
x
Network Clock Distribution Protocol
X
X
x
x
x
x
Simple Gateway Control Protocol
X
X
x
x
x
x
Inverse Multiplexing over ATM (IMA) groups
X
X
x
x
x
ATM End System Address (AESA) gateway
X
X
x
x
x
ATM overbooking
X
X
x
x
x
Framing overhead
X
X
x
x
x
NCDP MIB Support
X
X
x
x
L3-ATM routing and bridging via RFC 1483 (ATM router module)20
X
X
x
ACL support via ACL daughter card
X
X
x
Point-to-point subinterfaces, only point-to-multipoint subinterfaces are supported
X
X
SNMP provisioning of ATM interface traps to an SNMP Host
X
1 SNMP = Simple Network Management Protocol.
2 PPP = Point-to-Point Protocol.
3 SLIP = Serial Line Internet Protocol.
4 IP = Internet Protocol.
5 NTP = Network Time Protocol.
6 TACACS+ = Terminal Access Controller Access Control System Plus.
7 VCCs = virtual channel connections.
8 VPCs = virtual path connections.
9 IISP = Interim-Interswitch Signaling Protocol.
10 LANE = LAN emulation.
11 LEC = LAN emulation client.
12 LES = LAN emulation server.
13 BUS = broadcast and unknown server.
14 LECS = LAN emulation configuration server.
15 ASP = ATM switch processor.
16 ARP = Address Resolution Protocol.
17 OAM = Operation, Administration, and Maintenance.
18 RMON = Remote Monitoring.
19 MCR = minimum cell rate.
20 You can download the Catalyst 8510 software image on a LightStream 1010 ATM switch to support L3-ATM (via the ATM router module). However, the LightStream 1010 ATM switch software image does not include support for the ATM router module.
Release Names, Versions, and Part Numbers
Table 7 lists the release names, versions, and part numbers used with the Catalyst 8510 MSR and LightStream 1010 ATM switch. Platform-specific information is noted in the table. Table 8 lists the release names, versions, and part numbers used with the Catalyst 8510 CSR.
New and Changed Information
This section includes new features that appear in this and previous releases of Cisco IOS release 12.0W5 software. The new features are sorted by release number.
New Features in Release 12.0(28)W5(30a)
Catalyst 8510 MSR and LightStream 1010
No new features are available for the Catalyst 8510 MSR and LightStream 1010 switch in Cisco IOS Release 12.0(28)W5(30a).
Catalyst 8510 CSR
No new features are available for the Catalyst 8510 CSR switch in Cisco IOS Release 12.0(28)W5(30a).
New Features in Release 12.0(28)W5(30)
Catalyst 8510 MSR and LightStream 1010
No new features are available for the Catalyst 8510 MSR and LightStream 1010 switch in Cisco IOS Release 12.0(28)W5(30).
Catalyst 8510 CSR
No new features are available for the Catalyst 8510 CSR switch in Cisco IOS Release 12.0(28)W5(30).
New Features in Release 12.0(27)W5(29)
Catalyst 8510 MSR and LightStream 1010
No new features are available for the Catalyst 8510 MSR and LightStream 1010 switch in Cisco IOS Release 12.0(27)W5(29).
Catalyst 8510 CSR
No new features are available for the Catalyst 8510 CSR switch in Cisco IOS Release 12.0(27)W5(29).
New Features in Release 12.0(26)W5(28)
Catalyst 8510 MSR and LightStream 1010
No new features are available for the Catalyst 8510 MSR and LightStream 1010 switch in Cisco IOS Release 12.0(26)W5(28).
Catalyst 8510 CSR
No new features are available for the Catalyst 8510 CSR switch in Cisco IOS Release 12.0(26)W5(28).
New Features in Release 12.0(24)W5(26c)
Catalyst 8510 MSR and LightStream 1010
No new features are available for the Catalyst 8510 MSR and LightStream 1010 switch in Cisco IOS Release 12.0(24)W5(26c).
Catalyst 8510 CSR
No new features are available for the Catalyst 8510 CSR switch in Cisco IOS Release 12.0(24)W5(26c).
New Features in Release 12.0(24)W5(26b)
Catalyst 8510 MSR and LightStream 1010
No new features are available for the Catalyst 8510 MSR and LightStream 1010 switch in Cisco IOS Release 12.0(24)W5(26b).
Catalyst 8510 CSR
No new features are available for the Catalyst 8510 CSR switch in Cisco IOS Release 12.0(24)W5(26b).
New Features in Release 12.0(24)W5(26)
Catalyst 8510 MSR and LightStream 1010
The following new feature is available for the Catalyst 8510 MSR and LightStream 1010 ATM switch in Cisco IOS Release 12.0(24)W5(26).
•SNMP provisioning of ATM interface event traps to an SNMP host
Catalyst 8510 CSR
No new features are available for the Catalyst 8510 CSR switch in Cisco IOS Release 12.0(24)W5(26).
New Features in Release 12.0(22)W5(25)
Catalyst 8510 MSR and LightStream 1010
No new features are available for the Catalyst 8510 MSR and LightStream 1010 ATM switch in Cisco IOS Release 12.0(22)W5(25).
Catalyst 8510 CSR
No new features are available for the Catalyst 8510 CSR switch in Cisco IOS Release 12.0(22)W5(25).
New Features in Release 12.0(20)W5(24b)
Catalyst 8510 MSR and LightStream 1010
No new features are available for the Catalyst 8510 MSR and LightStream 1010 ATM switch in Cisco IOS Release 12.0(20)W5(24b).
Catalyst 8510 CSR
No new features are available for the Catalyst 8510 CSR switch in Cisco IOS Release 12.0(20)W5(24b).
New Features in Release 12.0(20)W5(24a)
Catalyst 8510 MSR and LightStream 1010
No new features are available for the Catalyst 8510 MSR and LightStream 1010 ATM switch in Cisco IOS Release 12.0(20)W5(24a).
Catalyst 8510 CSR
No new features are available for the Catalyst 8510 CSR switch in Cisco IOS Release 12.0(20)W5(24a).
New Features in Release 12.0(20)W5(24)
Catalyst 8510 MSR and LightStream 1010
No new features are available for the Catalyst 8510 MSR and LightStream 1010 ATM switch in Cisco IOS Release 12.0(20)W5(24).
Catalyst 8510 CSR
No new features are available for the Catalyst 8510 CSR switch in Cisco IOS Release 12.0(20)W5(24).
New Features in Release 12.0(19)W5(23)
Catalyst 8510 MSR and LightStream 1010
No new features are available for the Catalyst 8510 MSR and LightStream 1010 ATM switch in Cisco IOS Release 12.0(19)W5(23).
Catalyst 8510 CSR
No new features are available for the Catalyst 8510 CSR switch in Cisco IOS Release 12.0(19)W5(23).
New Features in Release 12.0(18)W5(22)
Catalyst 8510 MSR and LightStream 1010
No new features are available for the Catalyst 8510 MSR and LightStream 1010 ATM switch in Cisco IOS Release 12.0(18)W5(22).
Catalyst 8510 CSR
No new features are available for the Catalyst 8510 CSR switch in Cisco IOS Release 12.0(18)W5(22).
New Features in Release 12.0(16)W5(21)
Catalyst 8510 MSR and LightStream 1010
No new features are available for the Catalyst 8510 MSR and LightStream 1010 ATM switch in Cisco IOS Release 12.0(16)W5(21).
Catalyst 8510 CSR
No new features are available for the Catalyst 8510 CSR switch in Cisco IOS Release 12.0(16)W5(21).
New Features in Release 12.0(13)W5(19c)
Catalyst 8510 MSR and LightStream 1010
No new features are available for the Catalyst 8510 MSR and LightStream 1010 ATM switch in Cisco IOS Release 12.0(13)W5(19c).
Catalyst 8510 CSR
No new features are available for the Catalyst 8510 CSR switch in Cisco IOS Release 12.0(16)W5(19c).
New Features in Release 12.0(10)W5(18b)
Catalyst 8510 MSR and LightStream 1010
The following new features are available for the Catalyst 8510 MSR and LightStream 1010 ATM switch in Cisco IOS Release 12.0(10)W5(18b):
•Layer 3 ATM routing and bridging with RFC 1483 on the ATM router module
Note You can download the Catalyst 8510 software image on a LightStream 1010 ATM switch to support Layer 3 ATM (via the ATM router module). However, the LightStream 1010 image does not include support for the ATM router module.
•ACL support via the ACL daughter card (Catalyst 8510)
See the " Related Documentation" section for a list of documents that describe this feature.
Catalyst 8510 CSR
The following new features are available for the Catalyst 8510 CSR in Cisco IOS Release 12.0(10)W5(18b):
•Access Control List (ACL) daughter card
•ACL software features
See the " Related Documentation" section for a list of documents that describe this feature.
New Features in Release 12.0(7)W5(15c)
Catalyst 8510 MSR and LightStream 1010
The following new feature is available for the Catalyst 8510 MSR and LightStream 1010 ATM switch in Cisco IOS Release 12.0(7)W5(15c):
•NCDP MIB support
See the " Related Documentation" section for a list of documents that describe this feature.
New Features in Release 12.0(5)W5(13d)
Catalyst 8510 CSR
The following new features are available for the Catalyst 8510 CSR in Cisco IOS Release 12.0(5)W5(13d):
•BGPx4 routing protocol
•IP multicast scalability
•Bridging/IRB over 802.1Q
•Support for 16 bridge groups with up to 32 interfaces within each bridge group
•Support for the 1000BASE-ZX extended reach GBIC
See the " Related Documentation" section for a list of documents that describe these features.
New Features in Release 12.0(4a)W5(11a)
Catalyst 8510 MSR
The following new features are available for the Catalyst 8510 and LightStream 1010 ATM switch in Cisco IOS Release 12.0(4a)W5(11a):
•Inverse Multiplexing over ATM (IMA) Port Adapters
•ATM Overbooking
•Framing Overhead
•AESA Gateway
See the " Related Documentation" section for a list of documents that describe these features.
Catalyst 8510 CSR
The following new features are available for the Catalyst 8510 CSR in Cisco IOS Release 12.0(4a)WX5(11a):
•Support for Appletalk routing
•SPF Neighbor Optimizations
See the " Related Documentation" section for a list of documents that describe these features.
New Features in Release 12.0(1a)W5(9)
Catalyst 8510 MSR and LightStream 1010
The following new features are available for the Catalyst 8510 and LightStream 1010 ATM switch in Cisco IOS Release 12.0(1a)W5(9):
•Network Clock Distribution Protocol (NCDP)
•Simple Gateway Control Protocol (SGCP)
•PNNI Alternate Link Selection
•PNNI Explicit Paths
•Channelized DS3 Frame Relay Port Adapter
•Four-port 25-Mbps Port Adapter
•Tag Switching CoS
See the " Related Documentation" section for a list of documents that describe these features.
New Features in Release 12.0(1a)W5(6f)
Catalyst 8510 CSR
There are no new features for the Catalyst 8510 CSR for Cisco IOS Release 12.0(1a)W5(6f).
Caveats
This section lists the caveats and corrected caveats for each release. Use Table 9 to determine the status of a particular caveat and its relevancy to your software release for Catalyst 8510 MSR and LightStream 1010. Use Table 10 to determine the status of a particular caveat and its relevance to your software release for Catalyst 8510 CSR. In the tables, "C" indicates a fixed caveat, and "O" indicates an open caveat. Platform specific caveats are appropriately indicated.
Table 9 Caveats and Caveats Corrected Reference for Catalyst 8510 MSR and LightStream 1010
DDTS Number 12.0(28)W5(30a) 12.0(28)W5(30) 12.0(27)W5(29) 12.0(26)W5(28) 12.0(24)W5(26c) 12.0(24)W5(26b) 12.0(24)W5(26) 12.0(22)W5(25) 12.0(20)W5(24b) 12.0(20)W5(24a) 12.0(20)W5(24) 12.0(19)W5(23) 12.0(18)W5(22) 12.0(16)W5(21) 12.0(13)W5(19c) 12.0(10)W5(18b) 12.0(7)W5(15c) 12.0(4a)W5(11a) 12.0(1a)W5(9) 12.0(1a)W5(5b)C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
C
C
C
C
C
C
C
C
C
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
O
C
C
C
C
C
C
O
O
O
O
O
O
O
O
C
C
C
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
O
O
O
O
C
C
C
O
O
O
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
O
O
O
C
C
C
O
O
O
O
O
O
O
O
O
C
C
C
O
O
O
O
C
C
C
C
C
C
C
C
C
O
O
O
C
C
C
O
O
O
O
(Catalyst 8510
MSR)
O
O
O
O
O
O
O
O
O
O
O
O
(LightStream 1010)
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
O
O
O
O
C
C
C
O
O
O
O
O
O
O
O
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
O
O
O
O
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
O
O
O
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
CSCdu56774 · Catalyst 8510 MSR)
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
CSCdu37838 · Catalyst 8510 MSR)
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
CSCdu26719 · (Catalyst 8510 MSR)
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
CSCdu20618 · (LightStream 1010)
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
O
C
C
C
C
C
C
C
O
O
O
O
O
O
O
C
C
C
C
C
C
C
O
O
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
O
O
O
O
O
O
O
O
C
C
C
C
C
C
C
O
O
O
O
O
O
O
O
C
C
C
O
O
O
O
O
O
O
O
O
O
O
O
C
C
C
O
O
O
O
O
O
O
O
O
O
O
O
C
C
C
O
O
O
O
O
O
O
O
O
O
O
O
C
C
C
C
C
C
C
O
O
O
O
O
O
O
O
O
O
O
O
O
C
C
C
C
C
C
C
O
O
O
O
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
O
O
O
O
O
O
O
O
O
O
O
O
C
C
C
C
C
C
C
O
O
O
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
O
O
O
O
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
O
O
O
O
O
O
C
C
C
C
O
O
O
O
O
O
O
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
C
C
C
C
C
C
C
O
O
O
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
CSCds43859 · (Catalyst 8510 MSR)
C
C
C
O
O
O
O
O
O
O
O
O
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
C
C
C
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
C
C
C
C
C
C
C
O
O
O
O
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
O
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
O
O
C
C
C
C
C
C
C
O
O
O
O
O
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
C
C
C
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
C
C
C
O
O
O
O
O
O
O
O
O
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
C
C
C
C
C
O
O
O
O
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
C
C
C
O
O
O
O
O
O
O
O
O
O
O
O
O
O
C
C
C
O
O
O
O
O
O
O
O
O
O
O
O
O
O
C
C
C
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
O
O
O
O
O
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
C
C
C
O
O
O
O
O
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
CSCdp80826 · (LightStream 1010)
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
C
C
C
O
O
O
O
O
O
O
O
O
O
O
O
O
O
C
C
C
O
O
O
O
O
O
O
O
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
CSCdp30288 · (Catalyst 8510 MSR)
C
C
C
O
O
O
O
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
O
O
O
O
O
O
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
O
O
O
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
CSCdm43851 ·
(Catalyst 8510)C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
CSCdk87959 ·
(Catalyst 8510)C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
O
O
C
C
C
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
C
C
C
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
C
C
C
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
C
C
C
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
O
O
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
C
C
C
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
Caveat Symptoms and Workaround
This section contains listings of the caveats for the Cisco IOS software for the Catalyst 8510 MSR and LightStream 1010 switches.
•The maximum number of ELAN LES/BUS pairs that the ATM switch processor interface supports is 10.
•On configuring a Frame Relay NIW/SIW PVC, a small number of discarded frames are seen occasionally due to CRC errors. These discards happen even without passing traffic.
•CSCin67939
Symptom: The wrong payload pattern in idle cells might be transmitted from DS-3 and E3 interfaces.
As per I.361 Recommendation (of the ITU-T), the payload pattern of idle cell is "01101010" or "0x6A". But, in DS-3 and E3 interfaces of the Catalyst 8540 MSR, Catalyst 8510 MSR, and LightStream 1010 ATM switches the payload pattern of idle cell is set as "00000000" or "0x00". This is incorrect as per the ITU-T specification.
Some interoperability issues with other devices might appear if those devices expect only the "0x6A" pattern.
Workaround: None.
•CSCin67191
Symptom: Using the show vc command displays garbage data for TVC(I) type interfaces with multiple leaves. Data for TVC(O) type interfaces with multiple leaves are displayed correctly.
Note There is no functionality impact.
Workaround: Use the show atm vc command instead of the show vc command.
•CSCin67022
Symptom: A burst of noise on the physical link can cause the PNNI Hello for the link to stick in the down state on one end of the link and in the attempt state on the other end.
Workaround: Use the shutdown and no shutdown commands on the interface (or sub-interface) to cause the PNNI Hello to come up.
•CSCin37548
Symptom: The following issues could be seen on the simultaneous execution of certain PNNI CLIs:
The switch reloads when:
a. Through a console session run the show atm pnni topology command and wait for the more prompt to appear. Next, through a Telnet session delete the lowest level node. Press the Space key on the console session.
b. Through a console session run the show atm pnni neighbor command and wait for the more prompt to appear. Now through a telnet session delete the lowest level node. Press the Space key on the console session.
c. Through a console session run the show atm pnni background routes admin-weight command and wait for the more prompt to appear. Now through a telnet session delete the lowest level node. Press the Space key on the console session.
d. Through a console session run the show atm pnni exp-path detail command and wait for the more prompt to appear. Through a Telnet session delete all the explicit paths. Press the Space key on the console session.
The following issues are also seen:
e. Through a console session run the show atm pnni topology detail command and wait for the more prompt to appear. Now through a telnet session delete the lowest level node. Pressing Space key on the console session causes spurious memory access.
f. Through a console session run the show atm pnni aggregation node border-detail exception-detail command and wait for the more prompt to appear. Now through a telnet session delete the lowest level node. Press the Space key on the console session. The output is not aborted gracefully.
g. Through a console session run the show atm pnni database command and wait for the more prompt to appear. Through a Telnet session delete the lowest level node. Press the Space key on the console session. The output is not aborted gracefully.
h. Through a console session run the show atm pnni explicit-paths detail command and wait for the more prompt to appear. Through a Telnet session delete the lowest level node. Pressing the space bar on the console causes spurious memory access and tracebacks are seen.
Workaround: None.
•CSCin36885
Symptom: On a Catalyst 8510 MSR, if an OC-3 interface is overbooked and configured with PVCs that consume more than 599 Mbps of bandwidth, during bootup these PVCs are lost from the running configuration.
The following error message appears during bootup for every PVC that is rejected.
%connection creation fails: specified traffic/resource parameters are invalid
Workaround: Configure the PVCs that were lost once the switch boots up.
•CSCin14721
Symptom: The CBR interface module sends a "remote alarm" to the peer interface if the line flaps continuously. This causes the peer interface to change to "yellow alarm" state.
Workaround: Enter the shutdown and no shutdown commands on the CBR interface.
•CSCin13787
Symptom: When bursty traffic is sent to the ARM via a carrier module installed 1-port OC-12 interface module in a peer Catalyst 8540 MSR, the ARM interface displays underruns and drops packets.
Workaround: None.
•CSCin13430
Symptom: A memory leak might occur during an "atmSoft_timerProcess". With every "soft-vc" retry the holding memory on "atmsig CC" and "atm soft CV timer" increases and the "free" memory decreases. The free memory might fall to as low as 700K at times.
Workaround: None.
•CSCin12494
Symptom: The switch might reload if the show atm snoop-vc EXEC command is entered after an inverse multiplexing over ATM (IMA) interface that is being snooped is deleted.
Workaround: None.
•CSCin07783
Symptom: A fully utilized IMA group with eight E1 links is configured between two switches. The eight Soft-VCs are configured between the switches so that they each use the resources offered by an E1 link. When traffic is flowing across the links and three of the links of the IMA group on one switch are shutdown, traffic stops flowing through all Soft-VCs. Then, soon after, the three links are shutdown. Then, all Soft-VCs are torn down and none of the VCs come up again. They continue to remain in the NOT CONNECTED state.
Workaround: None.
•CSCin06808
Symptom: The switch crashes when using an ATM interface to snoop a tag-switching interface and you perform all of the following processes:
1. Configure snooping on the interface.
2. Unconfigure snooping on the interface.
3. Configure snooping on the interface again.
4. Shutdown the interface used for snooping.
Also, the following errors messages appear:
–"%ATMCORE-3-INTERNAL_ERROR: snoopDeInstall: close hw conn failure"
–"%AAL5-3-INTERNAL_ERROR: aal5send: mmc_queuecell failed"
Workaround: None.
•CSCin06080 (LightStream 1010)
Symptom: On a LightStream 1010 switch with an E1 interface connection, Detailed Device Report shows "slot number: N/A" but should display the actual interface slot number.
Workaround: None.
•CSCin04998
Symptom: If the ARM interface (on the Catalyst 8510) receives incomplete bridged PDU, the interface becomes portstuck.
Workaround: Configure the epc port-reload command for automatic recovery of portstuck.
•CSCin04617
Symptom: On the Catalyst 8540, Catalyst 8510 MSR, and the LightStream 1010 switches, Frame Relay traffic stops flowing through previously configured PVCs when you reload the image or reboot the switch. However, the VC appears up.
Workaround: None.
•CSCin03109
Symptom: If tag-switching is disabled on an interface being snooped and a show atm snoop-vc command is executed, the switch reloads.
Workaround: None.
•CSCin01661
Symptom: When the VCI range for tag switching is configured on an ATM interface, these VCI values are not reused when a new bind request is received.
Workaround: Disable and reenable tag switching on ATM interface.
•CSCin01222
Symptom: When you create a PVC with InARP configured, the PVCs was not linked to InARP chain. This means the broadcast packets are not sent through the InArp PVCs that are terminated on ATM0 interface. Because of this, routing updates are not sent causing OSPF/EIGRP neighbors to not be established.
Workaround: None.
•CSCee43876
Symptom: Soft PVC call setup might fail going through third-party ATM switches. These third-party ATM switches might use Extended QoS Information Element (0xEC) with "Acceptable Backward Peak-to-Peak Cell Delay Variation Identifier" without the corresponding cumulative forward and/or backward Peak-to-Peak CDV.
Workaround: None.
•CSCee23976
Symptom: A LightStream 1010 ATM switch might crash and display "0x602D5E58:usecdelay(0x602d5e10)".
Workaround: None.
•CSCee21006
Symptom: On an interface module with a soft-VC configured, if an interface is shut down or if the interface module is removed from the chassis the following cause code appears in the "debug atm sig-all" display of subsequent soft-VC requests:
cause = normal call clearing, location = User
This cause code is not correct. The "Resource Unavailable class definitions" cause code should appear.
Workaround: None.
•CSCee04449
Symptom: The Catalyst 8510 MSR might experience a memory leak on the Pool Manager and Frame Relay LMI.
Workaround: None.
•CSCed59895
Symptom: The CISCO-PROCESS-MIB is not present in Cisco IOS Release 12.0(4.6)W5(13) and Cisco IOS Release 12.0(24)W5(26c). You must configure SNMP on the switch.
Workaround: None.
•CSCed44734
Symptom: Using SNMP to create a Soft VC fails if the source leg is on a VP-Tunnel.
The UNDO_FAILED_ERROR appears and NOT CONNECTED appears in the X-Interface column of the show atm vc interface command display.
Workaround: None.
•CSCed38527
Symptom: A vulnerability in the Transmission Control Protocol (TCP) specification (RFC793) has been discovered by an external researcher. The successful exploitation enables an adversary to reset any established TCP connection in a much shorter time than was previously discussed publicly. Depending on the application, the connection may get automatically re-established. In other cases, a user will have to repeat the action (for example, open a new Telnet or SSH session). Depending upon the attacked protocol, a successful attack may have additional consequences beyond terminated connection which must be considered. This attack vector is only applicable to the sessions which are terminating on a device (such as a router, switch, or computer) and not to the sessions that are only passing through the device (for example, transit traffic that is being routed by a router). In addition, this attack vector does not directly compromise data integrity or confidentiality.
All Cisco products which contain TCP stack are susceptible to this vulnerability.
This advisory is available at http://www.cisco.com/warp/public/707/cisco-sa-20040420-tcp-ios.shtml, and it describes this vulnerability as it applies to Cisco products that run Cisco IOS® software.
A companion advisory that describes this vulnerability for products that do not run Cisco IOS software is available at http://www.cisco.com/warp/public/707/cisco-sa-20040420-tcp-nonios.shtml.
Workaround: None.
•CSCed27956
Symptom: A vulnerability in the Transmission Control Protocol (TCP) specification (RFC793) has been discovered by an external researcher. The successful exploitation enables an adversary to reset any established TCP connection in a much shorter time than was previously discussed publicly. Depending on the application, the connection may get automatically re-established. In other cases, a user will have to repeat the action (for example, open a new Telnet or SSH session). Depending upon the attacked protocol, a successful attack may have additional consequences beyond terminated connection which must be considered. This attack vector is only applicable to the sessions which are terminating on a device (such as a router, switch, or computer) and not to the sessions that are only passing through the device (for example, transit traffic that is being routed by a router). In addition, this attack vector does not directly compromise data integrity or confidentiality.
All Cisco products which contain TCP stack are susceptible to this vulnerability.
This advisory is available at http://www.cisco.com/warp/public/707/cisco-sa-20040420-tcp-ios.shtml, and it describes this vulnerability as it applies to Cisco products that run Cisco IOS® software.
A companion advisory that describes this vulnerability for products that do not run Cisco IOS software is available at http://www.cisco.com/warp/public/707/cisco-sa-20040420-tcp-nonios.shtml.
Workaround: None.
•CSCec80061
Symptom: A switched virtual circuit (SVC) may not get established causing ping command failures between routers. This symptom is observed in Cisco IOS Release 12.3.
Workaround: None.
•CSCeb52110
Symptom: On a Catalyst 8510 MSR running Cisco IOS Release 12.1(7a)EY, if you OIR the CES interface module the route processor might crash.
Workaround: None.
•CSCeb29970
Symptom: When establishing soft-VP between switches, if a VP number is used by the previous switch and if that switch sends an error stating that "VPI" is already used, then the switch receiving that error should use a different VPI number during its next retry attempt. For example
Switch-1 (1/0/0)-------(1/0/0) Switch-2 (1/1/1)---------(1/1/1) Switch-3 (1/1/0)
1. Assume a soft-VP call is getting initiated by Switch-1.
2. Assume that the node ID of Switch-3 is higher than Switch-2.
3. Assume that the Switch-2 ATM1/1/1 interface has a PVP configured with VPI 4 (ATM PVP 4).
In this scenario, when a call is initiated by Switch-1, it is forwarded by Switch-2 to Switch-3. Because the node ID of Switch-3 is higher than Switch-2, Switch-3 requests a VP number. If the request is for VPI 4 on Switch-3's ATM1/1/1, it will reach Switch-2's ATM1/1/1. Because there was a PVP configured on Switch-2's ATM1/1/1 interface with PVP 4, it is rejected stating that VPI is "unavailable". This error is sent to both Switch-1 and Switch-3. So, during the next attempt when Switch-3 requests a VPI number, it should request a different VPI number from 4.
Workaround: None.
•CSCeb13499
Symptom: Problems occur in CISCO-ATM-IF-PHYS-MIB implementation:
1. ciscoAtmIfPhysLineFebeErrors returns Path FEBE errors instead of Line FEBE
errors.
2. ciscoAtmIfPhysPathFebeErrors returns Line FEBE errors instead of Path FEBE
errors.
This only happens with OC-3/STM1 or OC-12/STM4 interfaces.
Workaround: Poll ciscoAtmIfPhysLineFebeErrors when you need Path FEBE errors and poll ciscoAtmIfPhysPathFebeErrors when you need Line FEBE errors.
•CSCea74771
Symptom: The ATM interface does not reset the VCI/VPI connection after restart.
Workaround: None.
•CSCea72899
Symptom: Soft PVC does not come up.
If a Soft PVC originates from a LightStream 1010 switch directly connected to an Alcatel switch, the Soft PVC never comes up. If the call originated from the Alcatel side, the Soft PVC comes up with no problem.
Note This occurs if the LightStream 1010 switch is running Cisco IOS Release 12.0(24)W5(26b) or LightStream 1010.
For example:
At UNI ATM interface:
atm soft-vc 1 455 dest-add xx.348f.8001.bbfc.0000.0ba0.6f10.4080.210a.2a01.00 1 455 rx-cttr 1 tx-cttr 1
Alcatel switch directly connected, ATM NNI, PNNI up and adjacency up:
show atm pnni neighbor
---
Neighbor Name: unknown, Node number: 40
Neighbor Node Id: 88:160:xx.348F8001BBFC00000BA06F10.408021810A00.00
Neighboring Peer State: Full
Link Selection For CBR : minimize blocking of future calls
Link Selection For VBR-RT : minimize blocking of future calls
Link Selection For VBR-NRT: minimize blocking of future calls
Link Selection For ABR : balance load
Link Selection For UBR : balance load
Port Remote Port Id Hello state
ATM12/0/3 1281000 2way_in (Flood Port)
---
Switch# show atm route
P I 40 0 UP 0 39.348f.8001.bbfc.0000.0ba0.6f10/104
---
But, if the show atm pnni dtl node 40 ubr command is used:
*Apr 10 23:11:21.218: PNNI: UBR route request from ATM_OWNER_UNKNOWN
*Apr 10 23:11:21.218: PNNI: To node 88:160:xx.
348F8001BBFC00000BA06F10.408021810A00.00
*Apr 10 23:11:21.218: PNNI: selected target node 40
*Apr 10 23:11:21.218: priority: 2 (40 0) pnni-remote-internal
*Apr 10 23:11:21.218: PNNI: Compute On-Demand Route Based On Admin Weight
*Apr 10 23:11:21.218: PNNI: Failed To Find An On-Demand Route,
Code: PNNI_RESOURCE_UNAVAILABLE
*Apr 10 23:11:21.218: PNNI: No Route To
88:160:xx.348F8001BBFC00000BA06F10.408021810A00.00
*Apr 10 23:11:21.218: PNNI: Send Source Route Reply
To Requestor: Code PNNI_RESOURCE_UNAVAILABLE
---
When the call is initiated from the LightSteam 1010 switch, nothing comes up over to the Alcatel switch. At the same time, when the call is initiated from the Alcatel switch, the Soft PVC comes up:
Switch# show atm vc interface atm 9/1/1
Interface VPI VCI Type X-Interface X-VPI X-VCI Encap Status
ATM9/1/1 0 5 PVC ATM13/0/0 0 72 QSAAL UP
ATM9/1/1 0 16 PVC ATM13/0/0 0 40 ILMI UP
>>Alcatel Init <<<<
ATM9/1/1 0 400 SoftVC ATM12/0/3 0 227 UP
>> LS1010 Init <<<<
ATM9/1/1 1 455 SoftVC NOT CONNECTED
Workaround: None.
•CSCea66219
Symptom: A memory leak occurs in the ATMSIG processes. This is observed using the show processes memory command. The ATMSIG processes hold increasing amounts of memory and free memory is decreasing.
Note This occurs on LightStream 1010 or Catalyst 8540 switches running Cisco IOS Release 12.0(24)W5(26b), Cisco IOS Release 12.1(12c)E1, or Cisco IOS Release 12.1(13)E.
Workaround: None. The switch must be rebooted to recover.
•CSCea48476
Symptom: POD fails with ATMDIAG_UNEXPECTED_PIF_INTERRUPT_ERROR.
POD (Parallel Optical Device) errors might occur in some LightStream 1010 switches.These errors occurred but the ports where the POD errors appeared were up and working. This problem appears to be a false error reported by POD.Workaround: None.
•CSCea33651 (LightStream 1010)
Symptom: After upgrading the LightStream 1010 software from Cisco IOS Release 12.0(13)W5(19c) to Cisco IOS Release 12.0(24)W5(26b) on the head-end, it is no longer able to successfully make an ATM call to the client (running Cisco IOS Release 12.0(8)). But, the client can make the call to the head-end.
These are Soft-VCs running over a PVP. The Soft-VCs NOT running over a PVP do not seem to be affected by the upgrade.
After downgrading back to Cisco IOS Release 12.0(13)W5(19c), the switch calls are established as they should from the head-ends.
Workaround: None.
•CSCea33595
Symptom: On a LightStream 1010 switch running Cisco IOS Release version 120-24.W5.26b, might crash due to a system restarted by bus error at PC 0x6063F9C8, address 0xD0D0D15.
Workaround: None.
•CSCea30004
Symptom: Whenever you attempt to update the Access Control List (ACL) attached to the management interface (Ethernet2/0/0) on the LightStream 1010 ATM switch the following error message appears:
ACL is not supported
ACL functionality on the interface is not affected.
Workaround: None.
•CSCea02355
Symptom: Cisco routers and switches running Cisco IOS software and configured to process Internet Protocol version 4 (IPv4) packets are vulnerable to a Denial of Service (DoS) attack. A rare sequence of crafted IPv4 packets sent directly to the device may cause the input interface to stop processing traffic once the input queue is full. No authentication is required to process the inbound packet. Processing of IPv4 packets is enabled by default. Devices running only IP version 6 (IPv6) are not affected. A workaround is available.
Cisco has made software available, free of charge, to correct the problem.
Workaround: This advisory is available at http://www.cisco.com/warp/public/707/cisco-sa-20030717-blocked.shtml
•CSCdz34607
Symptom: Ethernet interface modules fail Online Access Test after upgrade from Cisco IOS Release 12.0.5.W5.13 to Cisco IOS Release 12.0.22.W5.25.
Workaround: This access test failure is caused by the incompatibility of hardware version (4.1) and firmware version (2.1) of the Ethernet interface modules installed in the switch. By upgrading to the latest firmware version (3.3), this problem can be resolved.
•CSCdy81832
Symptom: Cell drops occur at an OC-12 interface module with a Hierarchical VP tunnel if the hierarchical VP tunnel is configured on interface 0, the primary Route Processor is in slot 8, and the secondary Route Processor has come up in slot 4.
This same problem might occur if a hierarchical VP tunnel is defined on interface 9, the primary Route Processor is in slot 4, and the secondary Route Processor has come up in slot 8.
This happens when the secondary Route Processor boots up and there is a Hierarchical VP tunnel on any of the interfaces that share the same MSC as the secondary Route Processor.
This does not occur if the Redundant Route Processor is never booted.
Workaround: Use slot 2 or slot 11 for OC-12 interface module with the hierarchical VP tunnel.
•CSCdy81424
Symptom: Same problem as DDTS CSCdx58649 · except the fix was not committed to the LightStream 1010 image.
Workaround: None.
•CSCdy80652
Symptom: Input errors on interface ATM0 are incrementing one per minute. Only Input errors counter is incrementing and no other counters (for example, CRC and other errors).
Workaround: None.
•CSCdy57099
Symptom: The Catalyst 8500 MSR switch might experience a memory leak with the IP Simple Network Management Protocol (SNMP) process.
Workaround: None.
•CSCdy50426
Symptom: After upgrading to Cisco IOS Release 12.0(20)W05(24b), your LightStream 1010 switch might lose PNNI neighbors. When the "Auto-Config" function becomes stuck, it causes PNNI neighbor loss and prevents Soft-PVCs from connecting.
Note ILMI and QSAAL do come up.
Workaround: Use the shutdown and no shutdown commands on the interfaces or reboot the switch to recover.
•CSCdy45231
Symptom: The IMA interface module does not generate a syslog message when the link goes down.
Workaround: None.
•CSCdy44850
Symptom: The network-clock-select priority system command disappears from the saved configuration after a reload.
After you enter the command in configuration mode, the parser automatically adds the keyword "clock" at the end of the command line. This causes the command to fail when reloading the configuration.
Workaround: None.
•CSCdy10719
Symptom: Hosts that do not transmit data frequently and are connected to the Catalyst 8500 switch through an 8-port Gigabit Ethernet module are intermittently unreachable.
The connectivity to the hosts eventually recovers.
Workaround: None.
•CSCdy10600
Symptom: Enable optipoll by default on switches running 12.0W5 based images to permanently remove ILMI/SNMP timing issues for ILMI keepalive messages.
Workaround: None.
•CSCdy07314
Symptom: A Catalyst 8500 MSR running Cisco IOS version 12.0(20)W5(24b) might crash with a bus error in the SNMP code.
Workaround: Disabling polling chassis MIBs might prevent the crash.
•CSCdx94423
Symptom: If you disconnect the transmit cable from an E1 CBR interface on a Catalyst 8540, the interface still appears up/up. No indication of error messages appear in the log files.
When the transmit cable is reconnected, it starts to transmit traffic again. However, if the transmit cable is disconnected multiple times, the link does not pass traffic even when the transmit cable is reconnected.
Workaround: Use the shutdown and no shutdown commands on the interface and it returns to normal, or disconnect the receive cable and reconnect it.
•CSCdx93120
Symptom: On a Cisco 6400 Node Switch Processor (NSP) running Cisco IOS Release 12.2(2)B and its derivatives, using the atm ping command to test a valid and active VP might fail with the following message:
Jun 20 15:56:17.742: %ATMCORE-3-INTERNAL_ERROR: atmCore_oamRcvPing: No match.
The failure occurs when running the ping towards specific destination ATM switches, and is dependent on the format of the loopback cell received from the destination ATM switches. The occurrence of this problem is difficult to predict and depends on the particular ATM switch implementation of the destination switch.
Workaround: None.
•CSCdx91019
Symptom: A Cisco 6400 NSP, running Cisco IOS Release 12.1(5)DB or 12.2(2)B, displays the following error message when you use the atm ping interface atm slot/subslot/port VPI VCI end-loopback command and enter the wrong VP/VC combination:
connection doesn't exist
Any future atm ping commands to any connections (both valid and invalid) always result in the same error message and the ping commands fails. It fails even if the connection is valid, and even if a VP ping is used (for example, no VC number is specified).
You can still use the IP ping command to diagnose the connectivity between the NRP2 (Node Route Processor 2) and NSP.
Workaround: None.
•CSCdx70586
Symptom: Loopback not working properly on ATM T1 interface module. Duplicate of DDTS CSCdw22559 ·.
Workaround: None.
•CSCdx61473
Symptom: A LightStream 1010 switch running Cisco IOS Release 12.0(19)W5(23) might display the following error messages in the log:
%SYS-2-NOBLOCK: idle with blocking disabled.
-Process= "ATMSIG Client", ipl= 0, pid= 77
CEST: %SYS-2-BLOCKHUNG: Task hung with blocking disabled, value = 0x1.
-Process= "ATMSIG Client", ipl= 0, pid= 77
Functionality of the switch is not affected.
Workaround: None.
•CSCdx58649
Symptom: Avaya PBX and Definity PBX interoperability testing.
The following caveats exist for signalled ATM point-to-multipoint (P2MP) connections and the debugging of issues related to them on the Catalyst 8500 ATM switches:
–Hardware processing to release connection IDs (VPI/VCI) on low-rate P2MP connections can be slow. When add party /drop party are issued in quick succession on such a connection, insufficient time is spent waiting for completion, which causes an unnecessary rejection of the add party. There is no workaround for this issue.
–When a slave NNI node (in terms of connection ID allocation) proposes a connection to the master, and the master then uses the proposed VPI/VCI itself (intending to give the slave-proposed-VC another connection ID), two SVCs end up owning the same underlying VC. The result is a dangling half-leg and possibly allocated bandwidth that is never returned. There is no workaround for this issue.
–Handling of unexpected values in the second byte of the ATM signalling message-type field is to drop the message. This is incorrect. There is no workaround.
–Several debug messages received during "error" debugging are normal events. This causes clogging of the log buffer with nonerrored messages. This is for "mmc errors" and "atm sig cc-errors".
Workaround: None.
•CSCdx47684
Symptom: On the LightStream 1010 switch, a PNNI PVC link on an NNI interface might flap after the link stabilizes and the ATM PNNI VC component does not come back up.
Workaround: "Bounce" the PNNI process using the no atm router pnni and atm router pnni configuration commands to disable and enable the PNNI processes.
•CSCdx40271
Symptom: An unexpected reload of the LightStream 1010 occurs when you try to set the MIB object pnniSummaryAddressSuppress (PNNI-MIB).
This occurs when there is a summary for an ATM address prefix and you are still trying to set a summary suppress for the same ATM address prefix through the SNMP interface.
Workaround: None.
•CSCdx29693
Symptom: An ARM configured with subinterface and PVCs loses IP connectivity over the active PVCs.
Workaround: Delete and reconfigure the PVC configuration to restore connectivity.
•CSCdx11136
Symptom: Power-on diagnostics fail on the Catalyst 8510 MSR when Cisco IOS Release 12.1(10)E or higher is loaded in the bootflash.
Workaround: None.
•CSCdx06532
Symptom: A SNMP get-request on the MIB object pnniLinkIfIndex that is defined in the PNNI-MIB module returns 0.
This symptom is observed on PNNI interfaces of Cisco ATM switches. The symptom does not occur on virtual path tunnel interfaces.
Workaround: None.
•CSCdx04773
Symptom: When the Cisco ATM switch is running UNI 4.0 with a Fore or Marconi switch, it might release a call because of unsupported traffic parameters.
This occurs when the Cisco ATM switch is connected to the other vendor equipment and configured to operate with UNI 4.0 version across the link and as a non-negotiated link. If any traffic parameter values are modified, the Cisco ATM switch treats this as a fatal error and releases the call.
Workaround: Hardcode the UNI version to 3.1
•CSCdw95262
Symptom: On Frame Relay soft VCs, all frames sent with DE (discard eligibility) bit set are dropped at the serial interface even when the UPC is configured as "tag-drop" for the Soft VC.
Workaround: None.
•CSCdw93109
Symptom: When using ATM Frame Relay IWF on a Catalyst 8500 MSR running Release 12.0(18)W5(22) or later, the output queue of the pseudo-ATM interface might go to 40/40 and remain there even if no traffic is going through the switch on the ATM-FR circuits.
Note A reload might be required to clean that counter but connectivity is not impacted.
Workaround: None.
•CSCdw90604 (LightStream 1010)
Symptom: Interoperability problem between LightStream 1010 and Compaq Server with ATM NIC if you pull out the optical fiber connection and reconnect it. If you do so, ILMI keeps restarting, and never stabilizes. You can use the shutdown command on the interface, then disconnect and reconnect the fiber optic connection and use the no shutdown command on the ATM interface to eliminate the problem. These commands cause ILMI to restart correctly.
Note Using the shutdown and no shutdown commands on the LightStream 1010 ATM interface after the disconnection and reconnection does not solve the problem.
Workaround: Follow these steps:
1. Reboot the server.
2. Use the shutdown and no shutdown commands on the des ATM-Switch-Interfaces.
3. Restart the ATM-NIC (only the NIC interface).
4. Bind the TCP-Stack.•CSCdw86290
Symptom: On an ATM router module (ARM) that is running Cisco IOS Release 12.0(13)W5(19c), the ARM port may become stuck when a backup server is moved to a different switch.
Workaround: Configure the epc port-reload global configuration command for autorecovery on the stuck ARM port.
•CSCdw84976
Symptom: When a port on a Catalyst 8510 CSR is configured as a snoop (monitor) port, the traffic on the snoop port becomes corrupted. Sniffing the same traffic on the attached Catalyst switch shows that the traffic itself is not corrupted. The problem occurs because the snoop port does not give reliable information to the monitoring station attached to that port.
Workaround: None.
•CSCdw84540
Symptom: LightStream 1010 switches running 12.0(X)W5 IOS may not completely adhere to the ITU-T Q.2971 "B-ISDN DSS2 UNI Layer 3 Specification for Point-to-Multipoint Call/Connection Control." This could affect interoperability.
Workaround: Configure UNI Version 3.1 on the LightStream 1010 ATM interfaces if the point-to-multipoint interoperability issue is observed.
•CSCdw70257
Symptom: A switch configured for IMA bundling may not log link up and down messages. Only messages displaying the clock changes are logged as in the following example:
04:23:21: %CLOCKSW: Switching from ATM1/1/1 to ATM1/1/0
04:24:26: %CLOCKSW: Unswitching from ATM1/1/0 to System
04:25:21: %CLOCKSW: Switching from System to ATM1/1/1
04:26:06: %CLOCKSW: Unswitching from ATM1/1/1 to System
As each interface recovers revertive clocking the messages appear correctly and source is recovered. Messages appear incorrectly if there are multiple links going up and down and only CLOCKSW messages are received without reporting status of the interface.
The correct physical status can be viewed properly with the show ima interface and show ima interface atm card/subcard/port detail commands. These commands accurately display the status of the port with usual counters.
Note This behavior is not seen when the switch is configured as stand alone.
Workaround: None.
•CSCdw65903
Symptom: An error can occur with management protocol processing.
Workaround: Use the following URL for further information: http://www.cisco.com/cgi-bin/bugtool/onebug.pl?bugid=CSCdw65903
•CSCdw43258 (LightStream 1010)
Symptom: If you use the show version command on a LightStream 1010 switch with a faulty PCMCIA card, the following error message might appear:
%SYS-3-CPUHOG: Task ran for 3708 msec (343/19), process = Virtual Exec, PC = %600AB140. -Traceback= 600AB148 60038620 60038D1C 60038734 600384D8 60038D1C 60038734 6044C190 6005809C 60057DDC 6004BF74
Workaround: Use a different flash PCMCIA card.
•CSCdw41639
Symptom: The switch silently drops OAM F5 with OAM intercept enabled.
The switch might drop OAM (Operation Administration and Maintenance) F5 END Loopback cells with its default configuration of OAM intercept.
Workaround: Disable OAM intercept to avoid dropping F5 OAM cells.
•CSCdw36579
Symptom: OIR of port adapters does not work as expected using 12.0 mainline software on the LightStream 1010.
Workaround: Use the latest W5 image or do not OIR the port adapters individually. OIR the carrier module, remove the port adapter and then reinstall the carrier module.
•CSCdw33641
Symptom: The console might hang if you use the hw-module subslot x/y reset command on the Frame Relay E1 port adapter.
Workaround: Shutdown all the controllers in the port adapter before issuing the hw-module subslot x/y reset command
•CSCdw27916
Symptom: Rate scheduling is the only scheduling algorithm used for CBR PCR. When use the show atm interface atm x/x/x command, CBR shows up as using WRR queue C2 instead of C1.
Workaround: None.
•CSCdw27572
Symptom: A LightStream 1010 running Cisco IOS Release 12.0(19)W5(23) might show an alignment error.
Workaround: None.
•CSCdw25030
Symptom: After upgrading to Cisco IOS Release 12.0(19)W5(23) the following error message appears in the system log:
*Nov 25 15:47:31: ACL Daughter Card detected on the PAMin Slot [9]
*Nov 25 15:47:32: ipc_send2wire: No Mlet code for type: 111
*Nov 25 15:47:32: ipc_send2wire: No Mlet code for type: 111
This has no effect on the switch.
Workaround: None.
•CSCdw22559
Symptom: When an IMA interface module is installed in the switch chassis, and if "loopback PIF" is configured on any OC-3 or OC-12 interface, loopback is NOT reflected when queried through SNMP. Loopback is NOT actually being set.
Workaround: None.
•CSCdw22219 (LightStream 1010)
Symptom: If PNNI continuously receives a high rate of corrupted PTSP packets over a long period of time, it can cause a large number of internal node numbers to be generated for false Node IDs. If the number of internal node numbers reaches 1032, it can cause a switch crash.
Under normal conditions, PTSP packets should have a very low rate of being corrupted. But if PNNI interfaces are tunneled through a network where the connections are rate limited to a too low rate, it can force cell drops which can corrupt packets.
Workaround: Troubleshoot and remove the cause of PTSP packet corruption.
•CSCdw21076 (LightStream 1010)
Symptom: A LightStream 1010 switch might crash due to a fatal alignment error during upgrade to IOS release 12.0(19)W5(23) if a Frame Relay interface module is installed.
Workaround: Revert to IOS Release 12.0(18)W5(22) to solve the problem.
•CSCdw15274
Symptom: A high number of cells stuck in the memory buffer causes the CPU to miss the periodic poll of a certain module or interface, leading to a port stuck message. Occurrences are random and there is no predetermined sequence of events that causes this to happen. On an initial diagnosis, it appears to be traffic related.
Workaround: None.
•CSCdw10699
Symptom: The output of the show memory command displays incorrect values for PrevF and NextF fields. This may result in the Exec stack getting corrupted. This has no impact on the performance of the switch.
Workaround: None.
•CSCdw09740
Symptom: For Frame Relay terminating PVCs on Catalyst 8540 MSR, Catalyst 8510 MSR, and LightStream 1010 switches, effective "Inverse ARP Frequency" value will be 60,000 times greater than the actual intended value.
Workaround: None.
•CSCdv89300
Symptom: Two Catalyst 8500 switches are connected with only one level of PNNI hierarchy on one switch (level:56) and three levels on the other switch (levels:56,64 and 104) and the switches are at the same peer group at the highest level. There are 15 CBR shaped tunnels and 15 unshaped tunnels on the connecting link between the switches. In this situation, UBR Soft-VCs are not set up between the switches when there are more than 10 CBR shaped tunnels configured on the link between the switches. Plus, memory is held up because of the Soft-VC setup retries. Eventually the amount of memory held up inhibits you from executing certain commands.
Workaround: None.
•CSCdv70086
Symptom: A Catalyst 8510 CSR might produce power supply error messages when writing to the bootflash:
kockopes#copy slot0:cat8510c-in-mz_120-18_W5_22.bin bootflash:
Destination filename [cat8510c-in-mz_120-18_W5_22.bin]? CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCC CCCCCCCCCCCCCCC
00:08:37: %CI-3-PSFAIL: Power supply 1 failureCCCCCCCCCCCCCCCCCCCCCCCC
00:08:40: %CI-6-PSOK: Power supply 1 OKCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCC
Workaround: None.
•CSCdv63139
Symptom: A Catalyst 8500 switch rejects SVC video calls. After first video call is built, all other video calls are rejected, and a message similar to the following is generated when a debug atm sig-all atm x/y/z command is entered:
ATMSIG(0/0/0:11 11,35 - 0023/00):
(vcnum:0) building cause code - cause = (0x23)requested VPCI/VCI not available, IE_cause = (0x23)requested VPCI/VCI not available, location = Private Network 1d02h: ATMSIG(0/0/0:11 11,35 - 0023/00):
(vcnum:0) Output Release Complete msg, Call Initiated(N1) state 1d02h: SIG->CC: Svc Event Release Completed, State Dead 1d02h:
ATMSIG(0/0/0:11 11,35 - 0023/00): (vcnum:0) Call Initiated(N1) -> Dead
Workaround: Upgrade the 8500 switches to Cisco IOS Release 12.1(7a)EY.
•CSCdv49358
Symptom: When a CES circuit carrying traffic is removed, there is no warning message shown.
Workaround: None.
•CSCdv44896
Symptom: When using snmpwalk and the getbulk operation on the MIB tree, a memory leak occurs.
Workaround: None.
•CSCdv41809
Symptom: On the CES module interface, the status reads UP/UP and the status of PVC to that interface is UP in even though there is no physical connection at that port.
Workaround: Perform shutdown and no shutdown on the interface to clear the erroneous status.
•CSCdv35065 (LightStream 1010)
Symptom: PNNI goes to "down" state on all interfaces and all adjacencies are lost.
Workaround: None.
•CSCdv25341
Symptom: A Catalyst 8540 MSR and Catalyst 8510 MSR connected via 8-port inverse multiplexing over ATM (IMA) port adapter modules change clocking configuration after the T1 interfaces bounce, resulting in a loss of synchronous clocking over the T1 IMA links. If synchronous clocking is required for circuit emulation service (CES), the CES circuit might report overruns or underruns.
Workaround: The Catalyst 8540 MSR and Catalyst 8510 MSR can be reloaded to return the clocking configuration to the original values. The T1 interfaces can be removed from the IMA group, and then can be added back and bounced. The txtiming values under the show controllers will change back to 0x2 and synchronous clocking is restored.
•CSCdv22655
Symptom: The following error message does not specify the offending CAM/or port adapter module.:
%OIR-3-LONGSTALL: Long bus stall (20000 s), the new PAM may not seated properly, Please remove it and try again
Workaround: None.
•CSCdv22476
Symptom: On Frame Relay to ATM Soft-VC PVC connections the Frame Relay UNI interface status is incorrect. The Soft-VC PVC status is marked Active only when the Soft-VC is established and its connection state is UP. If the Soft VC is not connected, the source end of Soft-VC indicates PVC status as INACTIVE instead of ACTIVE, while destination end of Soft-VC does not exists and hence indicates the PVC status as DELETED.
Workaround: None.
•CSCdv21398
Symptom: The Management Information Base (MIB) object "ifAdminStatus" shows "UP" for an ADMIN DOWN E1 Controller after a reload or a route processor switchover.
Workaround: Enter the no shutdown/shutdown command sequence on the controller.
•CSCdv15294
Symptom: On the Frame Relay interface module, if any DROPS occur, the INPUT/OUTPUT ERROR counter is incremented instead of INPUT/OUTPUT DROPS counter.
Workaround: None.
•CSCdv15245
Symptom: When Frame Relay ATM Soft-VC is set up in Frame Relay/ATM Network Interworking (FRF.5), the usage parameter control (UPC) on the passive side always sets to PASS, irrespective of the setting on the serial interface that is set by entering the frame-relay upc-intent tag-drop command. The default is PASS; when this is changed to tag-drop, the configuration does not reflect the change, and entering the show vc int serial command always shows the UPC intent as PASS.
Workaround: None.
•CSCdv12317
Symptom: You might need to specify a minimum VPI on Catalyst 8500 switches when it is communicating with a Cisco Broadband Switch Module (BXM) Series switch. If you don not, a Soft PVC might not be torn down because the Virtual Switch Interface (VSI) on the BXM interface uses VPI 0.
Workaround: None.
•CSCdv11126 (LightStream 1010)
Symptom: Single bit Errors have been observed on CES circuits originating on the same interface module if two other circuits would always carry non-spec-conform AAL1 SNP for SN=0. Only this very high number of SNP errors in 1/8 of all AAL1 cells causes the issue. Multiple SNP corrections that could be seen in production networks are handled correctly without data-loss or corruption.
This is an interoperability issue with a Lucent PSAX 2300.
•CSCdv09975
Symptom: When the shutdown/no shutdown command sequence is entered for a port in a CES card, a burst of bit errors can be observed on the circuit on some other port of the same port adapter.
Workaround: None.
•CSCdv08899
Symptom: On the Catalyst 8540 MSR and LightStream 1010 platforms, the option to set loop timing on OC-12 ports is not available.
Workaround: None.
•CSCdv06370
Symptom: Not all of the contents of the atmVcCrossConnectTable can be seen after the removal and re-insertion of a module. The message:
%ATMCORE-3-INTERNAL_ERROR: ATOM ERROR: ifCB_p=NULL for lowIf
is seen on the console during some SNMP get operations.
Workaround: None.
•CSCdv05916
Symptom: When an E1 IMA (inverse multiplexing over ATM) adapter is inserted into a chassis in which several other IMA adapters have already been added, the clock cannot be derived from the network.
Workaround: None.
•CSCdu83797
Symptom: Some point-to-multipoint crossconnnect entries are missing from the atmVcCrossConnectTable when the point-to-multipoint root if-index is higher than the if-index of the leaves.
Workaround: None.
•CSCdu83707
Symptom: Interfaces with Tag enabled get stuck in the TDP not ready state.
Workaround: None. The only way to bring up the Tag on such interfaces is via system reload.
•CSCdu77737
Symptom: A Catalyst 8510 reloads by bus error.
Workaround: None.
•CSCdu74491
Symptom: After reloading core switches, all neighboring switches running 12.0(16)W6(21) and 12.0(16)W6(21a) crash and a message similar to the following is generated:
Jul 14 02:48:23: %ATMSIG-3-FAILXCONN: Xconnect failed, xconn fail -Traceback= 6054A204 6054C0A0 60556188 60545538 6054561C 6009930C 600992F8 Jul 14 02:48:23: ATMSIG(9/1/0:0 0,78 - 0209/62): (vcnum:0) XConnected failed To Jul 14 02:48:23: ATMSIG(ATM13/0/0 0,64 - 0018/62): (vcnum:64) Jul 14 02:48:23: ATMSIG: CONNECTION MANAGER/CAC Xconn install request Port A - (9/1/0) : 0 vpi = 0; vci = 78 Port B - (13/0/0) : 0 vpi = 0; vci = 64; new vpi = 0; new vci = 64 existing vpi/vci for leg B Jul 14 02:48:23: ATMSIG: CONNECTION MANAGER/CAC Xconn install result CONN_INSTALL_RESULT_HW_FAIL
Workaround: None.
•CSCdu69809
Symptom: A port of a 4-port DS3 port adaptor for the LightStream 1010 and the Catalyst 8540 is in a yellow or red alarm state, and stops sending DS3 framing for a brief time when the alarm is cleared from the interface and the interface transitions to an up/up state. The loss of frame (LOF) can be seen when the Acterna tool TBERD is connected to the TX port of the DS3 port. This symptom occurs only on the Catalyst 8540 MSR and LightStream 1010.
Workaround: None.
•CSCdu65431
Symptom: If the ASP or 8515 MSRP installed in a Catalyst 5500 is OIR removed from the chassis, an installed OC-12 single-mode intermediate reach port adapter continues to send the cells on the OC-12 interface. The result is that the interface of an ATM device connected to this interface will continue to report an up/up state even though the interface is reporting constant errors. This affects all Cisco IOS versions for the 8510 MSR and LightStream 1010. The port adapters with the part numbers WAI-OC12-1SSLR= and WAI-OC12-1MM= do not exhibit this problem.
Workaround: None.
•CSCdu57105
Symptom: When using Cisco IOS Release 12.0(16)W5.21, a system crash with a bus error at imapam_mmcport_init occurs after the creation of the 131st interface.
Workaround: Remove any unused modules from the chassis so that additional virtual interfaces can be created.
•CSCdu56774
Symptom: 4-path load balancing is missing for Ethernet processor interfaces.
Workaround: None.
•CSCdu55104
Symptom: After an online insertion and removal (OIR) of a carrier module in the 8540 MSR, the input/output packet counters for the corresponding interfaces show incorrect values.
Workaround: Do not perform OIRs, or clear the counters on that interface.
•CSCdu37838
Symptom: The spanning tree protocol of a bridge-group cannot be changed.
Workaround: Deconfigure the bridge-group and then reconfigure it with a different spanning tree protocol.
•CSCdu35316
Symptom: When a user specifies a Soft PVP configured as VBR-NRT Service category in the ingress port, the service category at the egress interface of that switch is seen as UBR rather than VBR_NRT.
Workaround: None.
•CSCdu26719
Symptom: A Catalyst 85xx running Cisco IOS Release 12.0(13)W5(19c) experiences high multiservice route processor utilization when Internetwork Packet Exchange (IPX) networks are added to Bridge Group Virtual Interface (BVI) interfaces; as more IPX networks are added, multiservice route processor utilization increases.
Workaround: If configuring bridging over ATM router module subinterfaces, configure a map-list for the bridged virtual circuit, using the keyword "bridge".
For example:
interface ATM3/0/0.50 multipoint
no ip directed-broadcast
map-group b50
atm pvc 2 50 pd on interface ATM0/0/0 1 50
bridge-group 50
map-list b50
bridge atm-vc 50 broadcast
•CSCdu24272
Symptom: On ATM switches, the loopback IP address is not exchanged during ILMI negotiation with the neighboring switches. Consequently, the output of the show atm ilmi-status command indicates 0.0.0.0 as the peer IP address, even though a loopback address is configured.
Workaround: Configure the IP address on an Ethernet interface.
•CSCdu20618
Symptom: One side of a circuit emulation service (CES) E1 port of a LightStream 1010 switch connection remains consistently in the YELLOW alarm or ALARM INTEGRATION state.
Workaround: None.
•CSCdu16973
Symptom: When running cell-mode MPLS on a network of switch routers with redundant paths, conversion to MPLS after a routing change might take up to 4.5 minutes. OSPS converges normally.
Workaround: None.
•CSCdu10985
Symptom: An ARM interface might not bridge between ATM and the native VLAN.
Workaround: Configure some other non-functional VLAN as native.
•CSCdu09850
Symptom: On a Catalyst 8540 performing an ATM-Frame Relay internetworking function, the ATM-Frame Relay does not propagate when the Local Management Interface (LMI) indicates a permanent virtual connection (PVC) as inactive.
Workaround: None.
•CSCdu07640
Symptom: The no ip route-cache cef command might disappear from the running configuration of the BVI interface after reloading the switch router.
Workaround: None.
•CSCdu04045
Symptom: The entry for atmSoftPVccRetryThreshold feature has an incorrect default value of 0, rather than the correct default value of 1 that is shown in the ATM Soft PVC Management Information Base (MIB). A value of zero indicates that an infinite number of call attempts are required to increment the atmSoftPvcCallFailures object and thus disables alarms for the Soft PVCC.
Workaround: Set the atmSoftPVccRetryThreshold value to 1.
•CSCdu03975
Symptom: There is a noise problem with the CES PAM hardware version one.
Workaround: None.
•CSCdu02569
Symptom: When slot 0 is configured as the ARP client, the client might release the SVC within one minute of a ping.
Workaround: Use the subinterfaces of slot 0 as the ARP client instead.
•CSCdt93866
Symptom: Sending a crafted control NTP packet might cause a buffer overflow.
Workaround: Include the "ntp access-group serve-only" line in the configuration of the router.
•CSCdt91430
Symptom: Under a heavy load the switch router might misorder cells going out OC12 port adapter modules.
Workaround: Use the four-port OC12 modules designed for the Catalyst.
•CSCdt91339
Symptom: Attempts to create multipoint connections via the atmVcCrossConnectTable in the ATM Management Information Base (MIB) are unsuccessful.
Workaround: None.
•CSCdt86157
Symptom: The SNMP polling of the MIB object atmVplOperstatus (in Virtual Path MIB) for VP tunnels shows that the VPL is DOWN, even when the tunnel is UP (as shown by the CLI).
Workaround: None.
•CSCdt85859
Symptom: In bridging, the aging time of ethernet process interfaces is always set 300 seconds, despite what it is configured for.
Workaround: None.
•CSCdt81270
Symptom: The one-Port OC12 port adapter module might cause cell corruption. This will inevitably lead to packet corruption wherever segmentation and reassembly is performed to put the cells back into frames.
Workaround: None.
•CSCdt80934
Symptom: When a static route is added to and deleted from an interface that already has a static route connected to it, the packets are process-switched.
Workaround: Enter the clear ip route command.
•CSCdt78847
Symptom: On PVCs on a VP tunnel, attempts to configure usage parameter control (UPC) values other than "pass" might not succeed.
Workaround: Do not define the VP tunnel, just configure PVCs on the VPI.
•CSCdt78491
Symptom: Online Diagnostic Snake tests might send ILMI traps when an interface becomes active. This can cause clients on other inter-faces to reset ILMI.
Workaround: Disable the snake test by entering the no diagnostics online snake command in global configuration mode.
•CSCdt73634
Symptom: Cell memory might get stuck when ABR, IMA, and hierarchical VPs are combined.
Workaround: Enter the shutdown command on the IMA interface. Take the first link on the IMA interface out of IMA group. Enter the no shutdown command followed by the shutdown command on the interface. Enter the no shutdown command on the IMA interface.
•CSCdt71010
Symptom: ifTable Indexes might not match MIB-II table indexes.
Workaround: None.
•CSCdt70190
Symptom: If a switch processor switch over occurs, the IMA interface will remain in a waiting state. After this, entering the shutdown command and then the no shutdown command on the IMA interface will bring it to the "going down" state.
Workaround: To avoid this issue, disable online diagnostics before a switch processor switch over.
•CSCdt67260
Symptom: The switch router might crash when being polled by SNMP.
Workaround: None.
•CSCdt62555
Symptom: When using PNNI, another vendor's equipment might send an invalid PTSE update. If the switch router receives one of these invalid updates, the PNNI neighborship might not re-establish.
Workaround: None.
•CSCdt62368
Symptom: On Catalyst 5500 switches, the fabric integration module (FIM) loses ILMI prefix when more than 30 LANE clients that are configured on the FIM go down. The FIM eventually recovers the same ILMI prefix.
Workaround: None.
•CSCdt62215
Symptom: After resetting an E1 device connected to the CES port there might not be connectivity about Layer one.
Workaround: Enter the shutdown command followed by the no shutdown command on the CBR interface.
•CSCdt56793
Symptom: The Puma Driver might not update the ingress/egress heartbeat register pointers. Because of this, it might not poll these registers to monitor the ingress/egress health. In cases where the firmware crashes, it might not immediately detect the failure.
Workaround: None.
•CSCdt49005
Symptom: SVC signalling across a VP tunnel might not work after a reload.
Workaround: None.
•CSCdt47944
Symptom: When configuring Frame Relay Connection Traffic Table rows, if the values specified for traffic parameters PIR and BC are close to the maximum allowed, the MBS value computed for their corresponding ATM traffic table row might be incorrect.
Workaround: None.
•CSCdt47492
Symptom: On the OC-3c port adapter module, ILMI might remain in the "waitdevtype" state after a redundancy fail over.
Workaround: If the problem is seen on port 1-3, bring up port 0. If the problem is seen on port 5-7, bring up port 4. If the problem is seen on port 9-11, bring up port 8. If the problem is seen on port 14-15, bring up port 12. The port can be brought up by connecting a loopback cable, or just by using that port.
•CSCdt46026
Symptom: A switch router with OC3 port adapters and five Fast Ethernet interface modules might boot up with the following error message:
epif_aal5_fastsend: bad vcinfo This message may appear 100s
of times and slow down the boot process. Normal operation does not seem affected
once the 8500 has finished booting.
Workaround: None.
•CSCdt44930
Symptom: When a switch router sends a tag distribution protocol (TDP) bind request and does not receive an answer, the TVC remains unconnected. This might cause scalability problems in large networks because over time these TVCs might use up a large number of resources.
Workaround: Add a timer to clean up the VCs.
•CSCdt40530
Symptom: Switch routers running Cisco IOS Release 12.0(13)W5(19) or earlier might experience a memory leak when used with an NMS (Network Management System) running SNMP whenever it accesses PNNI tables.
Workaround: Turn off NMS polling of PNNI tables and instead use the CLI for determining any PNNI information.
•CSCdt24278
Symptom: The ATM router module sets the CLP of all cells to 1 when bridging is configured over a 1483 PVC. This occurs to cells being transmitted over the 1483 PVC only.
Workaround: None.
•CSCdt22167
Symptom: When a significant amount of traffic is pumped in an egress direction, it exhausts the resources on the data buffers in the egress direction, and a cell backlog occurs on the switching fabric. This results in periodic poll messages being sent to the firmware, declaring the firmware to be dead.
Workaround: Issue a shutdown/no shutdown command on the interface module or OIR the interface module.
•CSCdt18467
Symptom: The port stuck message might log to the system log.
Workaround: None.
•CSCdt15978
Symptom: The Telnet response over an ISL trunk might be very slow. This is because small ISL frames (under 94 bytes) are not padded, and some devices drop ISL frames that are smaller than 94 bytes.
Workaround: None.
•CSCdt15931
Symptom: System reloads are observed on the ATM switch processor that is running Cisco IOS Release 12.0(13)WA(19a). Reloads occur only on the Cisco Catalyst 5500 series switches that incorporate the WS-X5165 fabric integration module (FIM).
The following error message will occur:
%ALIGN-1-FATAL: Illegal access to a low address
*** System received a Bus Error exception ***
All other 12.0(X)W5(X) images will function normally with the WS-X5165 (FIM) installed.
Workaround: Update to Cisco IOS release 12.0(13)W5(19b).
•CSCdt10494
Symptom: An ATM router module interface indicates outgoing packets when that interface is administratively down.
Workaround: None. This does not impact functionality.
•CSCdt13517
Symptom: The switch router might stop switching some VCs and log error messages like the following:
12:37:34.793: ATMSIG(12/1/0:0 0,37 - 274610/00): (vcnum:0) XConnected failed To Jan 9 12:37:34.793: ATMSIG(12/0/1:0 0,268 - 398903/00): (vcnum:0) Jan 9 12:37:34.793: ATMSIG: CONNECTION MANAGER/CAC Xconn install request Port A - (12/1/0) : 0 vpi = 0; vci = 37 Port B - (12/0/1) : 0 vpi = 0; vci = 268; new vpi = 0; new vci = 268 existing vpi/vci for leg B Jan 9 12:37:34.793: ATMSIG: CONNECTION MANAGER/CAC Xconn install result CONN_INSTALL_RESULT_HW_FAIL
Workaround: Reload the switch router.
•CSCdt10494
Symptom: An ARM interface might indicate outgoing packets when that interface is administratively down. This does not impact functionality.
Workaround: None.
•CSCdt10434
Symptom: When there is a lot of signaling svc setup and teardown on an nni tunnel, interface calls might fail with a vpi/vci collision.
Workaround: Use a regular interface (no tunnels).
•CSCdt05674
Symptom: Continuous messages that state the port is dead, followed by a series of continuous tracebacks, will appear on the LightStream 1010 ATM switch. This occurs when the switch has an FC-PCQ feature card that has a lot of connections or a lot of LANE traffic running through it, and it displays these messages when an interface carrying most of that traffic is shut down at the peer switch.
Workaround: Update to Cisco IOS Release 12.0(13)W5(19c).
•CSCdt04356
Symptom: On a switch router performing the Frame Relay/ATM Network Internetworking function, when the Local Management Interface (LMI) indicates a PVC is inactive on an NNI interface, this information is not propagated by the Frame Relay/ATM software.
Workaround: None.
•CSCdt00616
Symptom: The atm ds4-scramble command might not program the PHY chip in the scrambling mode. This causes data loss if the other end is in scrambling mode.
Workaround: Disable scrambling at the other end.
•CSCds85282
Symptom: Power-on diagnostics hang, and the IOS is unable to boot, when ARM, Fast Ethernet, and OC-12 cards are all installed in the same chassis.
Workaround: None.
•CSCds78385
Symptom: IPX traceroute might skip the middle hop when the middle router is the Catalyst 8540 switch router.
Workaround: None.
•CSCds69507
Symptom: When an OIR is performed on an ARM module, the HSRP configuration might get lost.
Workaround: None.
•CSCds57303
Symptom: The ATM User-Network Interface (UNI) does not include a cumulative round-trip time parameter in the ABR call setup. This situation might cause interoperability issues with different vendor products.
Workaround: None.
•CSCds55768
Symptom: In multi-vendor environment, if the IMA side of another company's product does not support the test pattern specified in Inverse Multiplexing for ATM (IMA) Specification Version 1.1 by the ATM Forum, the Cisco IMA interface does not function.
Workaround: None.
•CSCds51590
Symptom: The OAM configuration for a frame-relay PVC is not preserved across the reload. If an OAM AIS/RDI is enabled on the ATM interface that carries a frame-relay PVC from a 1CT3 serial interface, and the system is reloaded with this saved configuration, the OAM is no longer enabled on the frame-relay PVCs.
Workaround: Update to Cisco IOS Release 12.0(13)W5(19c).
•CSCds51004
Symptom: The circuit emulation service (CES) address does not change when the switch router address is changed. When the global switch ATM address prefixes are added or deleted (via the atm address command), addresses registered for existing CES circuits are not changed.
Workaround: None.
•CSCds44008
MAC address is not present in the CAM table on bridging tests.
Symptom: Under certain conditions, a Catalyst 8510 CSR might not have a certain MAC address in the CAM table. This would lead to flooding of Layer 2 traffic for a short time until the MAC addresses are learned.
Workaround: Issue clear bridge group command.
•CSCds43859
Symptom: Although packets are being sent out from an ATM OC-12 interface module, the 5-minute output rate shown using the show interface atm command indicates 0 bits/sec output. This is not consistent with the output rate shown under the show atm traffic command.
Workaround: None.
•CSCds40925
Symptom: When the show atm interface traffic command is entered on a subinterface, the total number of cells that has passed might show incorrectly as zero.
Workaround: None.
•CSCds39855
Symptom: When the primary clock source is in the "unlockable"' state, and the clock fails over to the secondary clock, the router never reverts to the primary clock source, even when the connection is clean and the clock source is present.
Workaround: None.
•CSCds38890
Symptom: The present configuration does not work properly for frame reject (FRMR) and acknowledgement timeout messages. Occasionally a file transfer works normally, but most of the time it does not.
Workaround: None.
•CSCds37204
Symptom: Under heavy traffic conditions, the switch router might not respond to the Marconi switch poll in a timely manner, and the Integrated Local Management Interface (ILMI) signaling and Service-Specific Connection-Oriented Protocol (SSCOP) signaling restart, and all virtual circuits are torn down.
Workaround: None.
•CSCds33901
Symptom: When the reset button is pushed, the switch router might not boot the main-image, and eventually goes into ROMMON.
Workaround: None.
•CSCds35355
Symptom: A switch router running SNMP might have massive memory failures. SNMP might consume all memory and it will appear to be fragmented.
Workaround: None.
•CSCds29865
Symptom: When HSRP is configured on the eight-port Gigabit Ethernet interface module, HSRP connectivity might be disrupted after a remote link failure is followed by a link restoration.
Workaround: Configure another HSRP group with a higher number and move the standby configuration to that group.
•CSCds28912
Symptom: IP traffic is not sent over a PVC if AAL5 MUX encapsulation is used on a point-to-point subinterface on the Catalyst 8540 MSR. If the deb atm errors command is enabled, the following error messages will appear:
point-to-point interface does not have a VCD
Workaround: None.
•CSCds08237
Symptom: The hierarchical VP tunnel configuration fails on a WAI-OC3-1S3M mixed mode port adapter module when it is in slot 0 subslot 1 of the C85MS-SCAM-2P carrier module. Slot 0 subslot 0 of the carrier module can either be empty or have another card in it, and hierarchical VP tunnel configuration will still fail. However, if the mixed mode pam is inserted in slot 0 subslot 0 of the carrier module, then the hierarchical VP tunnel can be configured.
Workaround: None.
•CSCds07238
Symptom: 64-bit octet counters might not be supported in the ifXTable.
Workaround: None.
•CSCds04747
The switch router might be vulnerable to the successful prediction of TCP Initial Sequence Numbers.
Symptom: The switch router might be vulnerable to the successful prediction of TCP Initial Sequence Numbers. This vulnerability only applies to the security of TCP connections that originate or terminate on the affected Cisco device itself; it does not apply to TCP traffic forwarded through the affected device, in transit between two other hosts.
Workaround: Update to Cisco IOS Release 12.0(13)W5(19c).
•CSCds00513
Symptom: When serial interfaces on a Frame Relay/ATM internetworking port adapter are oversubscribed, and significant data bursts occur simultaneously on multiple VCs on multiple serial interfaces, one serial interface might get stuck.
Workaround: Enter the hw-module slot/subslot command.
•CSCdr97847
Symptom: No SNMP trap exists corresponding to the following syslog message:
%ATM-4-ILMIKEEPALIVEFAIL.
Workaround: Enable syslog traps on switch to capture these failures
•CSCdr96966
Symptom: When attempting to monitor the status of each module in the switch router, using SNMP and querying two object indentifiers (OIDs), does not display all modules in the ciscoLS1010ModuleOperStatus field. The modules that are reported as unknown are seen when the show hardware command is entered.
Workaround: None.
•CSCdr96613
Symptom: After replacing an ATM 155-Mbps multimode port adapter with an ATM 155-Mbps single-mode port adapter, the SNMP agent might not correctly refresh the AtmIftable: it still returns the old ciscoAtmIfPortType information for the new module. Stopping SNMP and then restarting the SNMP agent does not correctly refresh the table.
Workaround: Reload the switch router.
•CSCdr86285
Symptom: The output of the EXEC command show atm controllers atm 2/0/0 is incorrect. Interfaces with spurious card/subcard/port IDs are displayed, duplicating valid interface displays.
Workaround: None.
•CSCdr86044
Symptom: Release message uses the wrong cause and diag information.
Workaround: None.
•CSCdr81329
Symptom: When the network clock module quality is not accurate the NCDP will automatically disable. It is normal behavior of ncdp.
You can check the ncdp status with the following:
switch#sh ncdp port atm2/0/0
port data --(35)-----ATM2/0/0--------------
port_id : 35
state : disabled
^^^^^^^^
Workaround: None.
•CSCdr78226
Symptom: A Catalyst 8540 with an ARM module, might take a software forced crash when attempting to establish EIGRP adjacencies.
Workaround: None.
•CSCdr76839
Symptom: Insufficient options for the show vc traffic and show vp traffic commands.
Workaround: None.
•CSCdr68605
Symptom: The following message can appear when a peer devices transmits an incorrect signalling packet:
SYS-2-BADSHARE: Bad refcount in datagram_done
This can lead to a memory corruption.
Workaround: None.
•CSCdr68425
Symptom: Cannot create a soft VC with 95% of PVP.
Workaround: None.
•CSCdr66855
Two-port enhanced Gigabit Ethernet interface module does not come up when the system is booted.
Symptom: If the peer device has a non-HP GBIC and is not seated properly, the "Optical Detect" LED will be OFF on this device.
Workaround: Issue the shutdown and no shutdown commands or reseat the GBICs after a power cycle.
•CSCdr66338
Symptom: The static bridge command might disappear from the running configuration.
Workaround: None.
•CSCdr64482
Problem with GBIC SX with no negotiation auto.
Symptom: The 1000BASE-SX GBIC interface of a Catalyst 8540 CSR does not support the no negotiate auto mode when connected to a Catalyst 5500 with the same GBIC.
Workaround: None.
•CSCdr63428
%IPC-5-NULL: Recd. msg Dest Port=0x0, seq = 3FF,ipc_process_message
Symptom: The above message might appear when booting the switch router with IPX traffic. The switch router will recover from this.
Workaround: None.
•CSCdr62978
HSRP interface does not preempt after the shutdown and no shutdown commands are issued.
Symptom: An HSRP interface configured for "preempt" might not become active after reset. No error message is given.
Workaround: Set higher priority for "preempt" interfaces as a second decision instance.
•CSCdr62898
Symptom: Per-VC drop counters are not consistent. This applies only to non-packet discard connections. The inconsistencies are between the three per-VC statistics: total RX cell drops, RX UPC violations, and RX clp0 q full drops. The total of RX UPC violations and RX Clp0 q full drops exceeds the total RX cell drops count. However, the total RX cell drops is accurate.
Workaround: None.
•CSCdr61171
Symptom: A timeout system crash can occur when a shutdown/no shutdown command sequence is issued on an interface with several bridge groups configured. The following console message appears:
%SYS-2-WATCHDOG: Process aborted on watchdog timeout, process = PIM Process.
Workaround: None.
•CSCdr59877
Symptom: The output of the show interface ethernet command might display a `lost carrier' count that is the same as that for the collision counter on that Ethernet interface. This is a counter error only, and does not actually indicate a lost carrier.
Workaround: None.
•CSCdr59347
Symptom: If two Catalyst 8540 CSRs with two-port Gigabit Ethernet interface modules are connected back-to-back, packets are lost. On one side the counters might show input and output increasing, but the other side shows only output packets increasing. The Address Resolution Protocol (ARP) from the other side is lost, and the ability to ping the other side is lost.
Workaround: Reset the GBIC.
•CSCdr58338
%LSS-4-INTERNAL_WARNING: lss_record_ri_ingress: Illegal channel %d
Symptom: The above message might appear when changing the trunk encapsulation type of a Gigabit EtherChannel (GEC) from ISL to 802.1q, when GEC is configured for novell-ether encapsulation and ports are receiving IPX wire speed traffic. No functionality problems are observed.
Workaround: None.
•CSCdr56798
Forwarding large packets on the ATM uplink can cause a port to be stuck on the enhanced Gigabit Ethernet ports.
Symptom: Due to a hardware limitation, any packets larger than 6K could potentially cause a port stuck. After a port is stuck, the normal port stuck recovery mechanism applies.
Workaround: None.
•CSCdr54230
Symptom: When running Border Gateway Protocol (BGP), the BGP peers of the receiving border router might detect a mismatch in the code, and issue a notification message to reset their session. This does not affect the receiving border router.
Workaround: None.
•CSCdr54231
Symptom: Notifications sent or received are only visible if the debug ip bgp command is configured. This might limit the ability to diagnose problems.
Workaround: None.
•CSCdr51414
Symptom: In a switch equipped with circuit emulation service port adapters, the shutdown of the CBR interface does not affect the device connected to it.
Workaround: None.
•CSCdr50435
Symptom: IP PIM Sparse-Mode using multipoint signaling over ATM might fail when the PNNI path is switched to the redundant link.
Workaround: Use regular point-to-point SVC connections instead of multipoint signaling, or use IP PIM Dense Mode.
•CSCdr49975
Symptom: Cannot set ifAdminStatus object on CES interfaces.
Workaround: None.
•CSCdr48014
Symptom: Open Shortest Path First (OSPF) updates might be corrupted on a Cisco 7500 series router using Multiprotocol Label Switching (MPLS) with Cisco Express Forwarding (CEF) output features enabled (including "service policy output"). IP routes are temporarily deleted from the IP routing table and a loss of connectivity might occur.
Workaround: Configure the ip cef global configuration command, save the configuration by using the copy running-config start-config command, and reload the switch. An alternative workaround would be to enter the memory cache-policy io uncached command. However, entering this command might affect packet switching performance.
•CSCdr45513
Symptom: When the switch router is reloaded, you must enter the shutdown command followed by the no shutdown command on the CBR ports in order to activate the CBR ports.
Workaround: None.
•CSCdr44264
Symptom: The switch crashed after a shutdown/no shutdown command sequence on interface ATM 0 when 230 SVCs were configured on the route processor port.
Workaround: None.
•CSCdr43326
Symptom: The atmVcCrossConnectAdminStatus entries might disappear.
Workaround: None.
•CSCdr43159
Some interfaces in the outgoing interface list of the IOS multicast table might not forward traffic.
Symptom: When the Catalyst 8540 CSR has both Protocol Independent Multicast (PIM) joins and IGMP joins coming in, one of the interfaces in the outgoing interface list of the IOS multicast table might not forward traffic. This is caused by a disconnect in the sequence of events between IOS multicast code and the Catalyst 8540 CSR specific light stream inter process communication subsystem (LSS) multicast code.
Workaround: Enter the clear ip multicast-routing command and configure static multicast groups on the interfaces sending PIM joins.
•CSCdr36952
Symptom: The switch router will crash and hang when ip http server is configured and a browser connects to http://<router-ip>/%%. This defect can be exploited to produce a denial of service (DoS) attack. This information has been announced on public Internet mailing lists which are widely read by both security professionals and by security "hackers," and should be considered public information.
Workaround: Disable the IP http server with the following command: no ip http server
Alternatively, the administrator can block port 80 connections to the switch router via access lists or other firewall methods. For further information, refer to the security advisory available at http://www.cisco.com/warp/public/707/advisory.html.•CSCdr36422
Symptom: VP Tunnel deletions leave behind stray SVC blocks.
Workaround: None.
•CSCdr35301
Symptom: ifOutOctets wrapping at 3000000 on an ATM interface.
Workaround: None.
•CSCdr32958
Symptom: CPU hog by OIR handler.
Workaround: None.
•CSCdr30421
Symptom: Multicast stats shows an incorrect rate in kbps.
Workaround: None.
•CSCdr28797
Symptom: HVPT: Incorrect scheduling values installed for low PCR. When a HVPT with a PCR of 2 kbps is configured on a OC-3 interface, this results in the cell starving of WKVC on the main interface.
Workaround: None.
•CSCdr26204
Symptom: When a switch is running release 12.0(4a)W5(11a) and the OSPF area range command is used, the summary LSA created might get stuck in the database and not be flushed after the command is removed from the configuration.
Workaround: None.
•CSCdr25535
Symptom: A failure trap is not generated when an IMA group gets deleted. The function which sends the trap is called from the alarms processing action function. In case of group deletion the driver stops sending alarm processing commands and thus it will not sense any group state changes that cause a trap to be generated.
Workaround: None.
•CSCdr20326
Symptom: DS3 Frame Relay port adapter firmware hangs with 16 channel groups oversubscribed.
Workaround: None.
•CSCdr20193
Symptom: 8540msr reload by bus error in handle_new_collect
Workaround:
•CSCdr07165
Symptom: A bus error exception might occur when adding parties to a root connection.
Workaround: None.
•CSCdr02365
Symptom: The output from the show bridge commands are incomplete.
Workaround: None.
•CSCdr01726
Symptom: The ILMI status of shaped and hierarchical tunnel subinterfaces that are down (not shutdown) appear stuck in the Restarting state after a shutdown/no shutdown command sequence.
Workaround: None.
•CSCdr00623
Symptom: Soft PVCs might be disabled on subinterfaces.
Workaround: None.
•CSCdr00483
Symptom: The Frame Relay/ATM port leg might go out of sync while attempting to delete a connection and port snooping is enabled.
Workaround: Disable snooping on the ATM port before attempting to delete a Frame Relay PVC.
•CSCdr00463
Symptom: The show controller command does not reflect T1 loopback configuration.
Workaround: None.
•CSCdp97152
Symptom: The switch might fail to periodically send poll PDUs when running 12.0 code with UNI version set to 3.0. This might result in no_response_timer expirations and flapping of the SSCOP link.
Workaround: Configure UNI 3.1 on the interface.
•CSCdp95194
Symptom: A LightStream 1010 configured for MPLS (tag switching) and running the Cisco IOS 12.0(9) maintenance software release does not correctly increment counters on outgoing TVCs, although the data are being correctly sent out of the TVC.
Workaround: Upgrade to Cisco IOS Release 12.0(4a)W5(11a) or higher.
•CSCdp94338
Symptom: ATM Feature request for ILMI-STATUS SNMP MIB.
Workaround: None.
•CSCdp86120
IPC not freed after continuous failure.
Symptom: When a port is temporarily stuck (such as egress starvation for a slightly extended period of time) there might be a memory leak. This happens very rarely when a port is temporarily stuck repeatedly.
Workaround: Schedule a reboot when the available memory goes down to a very low value. This caveat is fixed in Cisco IOS Release 12.0(5)W5(13b) and later releases.
•CSCdp85211
Symptom: ATM signalling would not generate the connect ACK message and would result in conformance test failure.
Workaround: None.
•CSCdp84968
Allocated VCs are not released if current VC leaf cannot be added.
Symptom: Under some very heavy stressful conditions with IP multicast, when the mcast fan-out expansion fails, the VCs do not release correctly.
Workaround: Stop the traffic and enter the clear ip mroute* command.
•CSCdp82442
Addition of SR3 and SR5 to the show controller counters command.
Symptom: Added code to display the SR3 and SR5 registers. No impact to functionality.
Workaround: The show controller counters command is enhanced in Cisco IOS Release 12.0(5)W5(13b) and later releases.
•CSCdp81517
Inconsistency with IPX EIGRP.
Symptom: If you are using IPX EIGRP, you might experience an inconsistency in SAP updates on a remote router if the serial interface is brought down for a brief time and then brought up.
Workaround: Enter the clear ip eigrp neighbors EXEC command or enter the no ipx linkup-request sap command for the serial interfaces.
•CSCdp80826
Symptom: OAM F5 loopback cells do not pass across 25-Mbps port adapter interfaces.
Workaround: Configure the global configuration command no atm oam intercept end-to-end on the switch.
•CSCdp80179
Commit new IPX cross encapsulation algorithm. Disable per packet load balancing.
Symptom: When IPX packets are sent to the system, and the system does cross encapsulation for IPX packets, it might lead to a stuck port situation if the IPX protocol length is wrong (or corrupt).
Workaround: Remove the interface module and reinstall it.
•CSCdp79109
Symptom: The switch might have spurious memory access tags after configuring and unconfiguring tag switching on different ATM interfaces. This is not known to impact tag switching functionality on the switch. The following message might appear on the console:
*** gd03_tag_stress: Mon Jan 31 08:35:12 2000 949336512 comment Spurious
memory accesses on gd03_r55_11: count = 1 ***
*** gd03_tag_stress: Mon Jan 31 08:35:12 2000 949336512 comment 1C
1 0x60254C28 0x60236140 0x6009868C 0x60098678
Workaround: None.
•CSCdp79042
Symptom: A switch router with the Per-Class Queueing Feature Card (PCQ FC) might not count received cells per VC on transit VCs.
Workaround: None.
•CSCdp77640
IPX node address of BVI interface becomes invalid.
Symptom: IPX node address of BVI is sometimes made invalid after a long period of time.
Workaround: Enter the shutdown and no shutdown commands on the BVI interface to recover. The node entry is programmed properly back in the table.
•CSCdp75662
There are memory leaks when the process to enqueue message fails.
Symptom: There are memory leaks under certain conditions when the process to enqueue message fails.
Workaround: Upgrade to Cisco IOS Release 12.0(5)W5(13b) or a later release.
•CSCdp75180
Symptom: The switch does not correctly handle extended QoS and end-to-end transit delay IE. This occurs primarily when operating with third-party vendor equipment.
Workaround: None.
•CSCdp74432
The message memory is not freed if the packet buffer is exhausted.
Symptom: When buffer pool exhaustion happens under heavy stress and buffer allocation fails there is a leakage of memory because of queued messages.
Workaround: Upgrade to Cisco IOS Release 12.0(5)W5(13b) or a later release.
•CSCdp72650
Symptom: Multiple tags for the default route might occur with VC-merge.
Workaround: Do not use the tag-switching ip default-route command to assign tags to the default route.
•CSCdp72498
BVI input queue gets wedged and blocks traffic on a bridge group.
Symptom: Under very specific traffic conditions, the input queue on the BVI interface might become wedged (that is, the input queue count is larger than the queue depth). This affects traffic from the same bridge group.
Workaround: Increase the hold queue on the BVI interface. Depending on the rate at which the input queue fills up, this might be temporary. Or redesign the network (remove BVI).
•CSCdp70087
Symptom: When the system receives a lot of bad IPX packets, it sometimes produces a spurious memory access error. This does not impact functionality.
Workaround: Upgrade to Cisco IOS Release 12.0(5)W5(13b) or a later release.
•CSCdp66611
Symptom: VP associated signalling code point not supported between the switch router and the Vswitch on UNI 4.0/IISP interfaces. This is an interoperability problem with the V switch. When the tunnels are configured on UNI/IISP interface, the switch router sends connection Id IE with the VP associated signaling code point. This code point is not supported on UNI/IISP links. Hence the Vswitch releases the call.
Workaround: Use the atm signalling vpci [value] command to configure the value of VPCI that is carried in the signaling messages within a VP tunnel.
•CSCdp66533
Symptom: Connected route associated with Ethernet interface might be intermittently missing from routing table.
Workaround: None.
•CSCdp66044
Symptom: When a port is stuck there is no debugging aid.
Workaround: Upgrade to Cisco IOS Release 12.0(5)W5(13b) or a later release.
•CSCdp64865
Symptom: When the ipx down command is entered, the IPX routing flag is still on.
Workaround: Upgrade to Cisco IOS Release 12.0(5)W5(13b) or a later release.
•CSCdp63799
Symptom: New SVC or soft PVC calls from a Catalyst 8510 MSR switch or
LightStream 1010 ATM switch to a Fore ATM switch across a PNNI interface fail to connect. Connections initiated from the Fore switch do not fail.Workaround: None.
•CSCdp61799
Symptom: Under high traffic conditions the system crashed after failing to queue IPC messages.
Workaround: Reboot the system.
•CSCdp61681
Symptom: Counter values from the show controllers command are not descriptive enough for troubleshooting purposes. Each counter should have a label indicating the purpose of the counter.
Workaround: The output has been improved in Cisco IOS Release 12.0(5)W5(13b) and later releases.
•CSCdp57307
Symptom: A Cisco Catalyst 5000 might treat the link between the physical interface and the port channel interface as a multi-drop link when the MAC address of members of a port channel is different from the MAC address of the Port Channel (PO) itself.
Workaround: Delete the members of the port channel and then add them back.
•CSCdp57023
Symptom: The ifAdminStatus remains UP even when the controller is ADMINDOWN.
Workaround: None.
•CSCdp54010
Symptom: Some of the interface counters display a lower value for packet counters. Increasing the frequency of poll for statistics resolves the problem. This is needed only in two-port Gigabit Ethernet interface modules because of separate channels. This does not affect functionality.
Workaround: Upgrade to Cisco IOS Release 12.0(5)W5(13b) or later.
•CSCdp53470
Symptom: ATMVcCrossConnectLowHighIfIndex implementation problem inconsistent with RFC 1695.
Workaround: None.
•CSCdp52147
Symptom: When configuring a port channel, set the hold-queue size of the port channel to 300 and save it to NVRAM. On physical interfaces and port channels, the default hold-queue size is 75. The port channel hold-queue size should be 300. If the queue size of the port channel is not reset, there might be occasional packet drops bound to the route processor.
Workaround: None.
•CSCdp51216
Symptom: When an IMA card is present, and the system runs out of memory for any reason, the system might also crash.
Workaround: None.
•CSCdp50167
Symptom: IMA group fails to come up intermittently, especially after reload and on E1 IMA links.
Workaround: Go to one of the IMA interfaces and give the following command:
Switch(config-if)# fwmon "altrap 00 ff 00 ff 00 ff"
If the group still remains down, it indicates a persisting alarm on the line. The line configuration has to be checked to clear the problem.
•CSCdp49173
Symptom: When hundreds of TVCs in bidirectional mode are repeatedly configured and unconfigured on a switch router, VC resources might be exhausted.
Workaround: None.
•CSCdp48903
The show epc ipmcast command sometimes reports an incorrect value.
Symptom: The packet statistics displayed by the show epc ipmcast command sometimes report an incorrect value. This does not impact any functionality.
Workaround: Upgrade to Cisco IOS Release 12.0(5)W5(13b) or a later release.
•CSCdp43220
Symptom: When configuring the snmp trap receiver with the snmp-server host command, the following error message might appear:
%Bad oid failed to create host entry when configuring snmp host
Workaround: This error message only occurs when SNMP is initially configured on the switch and it is the first time that the snmp-server command is issued. If the command is entered again the error message is not seen.
•CSCdp43184
Symptom: The status of the PVC on the DCE is always ACTIVE. The PVC is not INACTIVE when interface (DTE) is shutdown.
Workaround: None.
•CSCdp34836
Symptoms: Sometimes during FEC learning, entries might not be learned right away. During this 3-4 minute period there might be flooding. After that, the entries will be learned and packets will be switched.
Workaround: None.
•CSCdp31976
Symptom: If a switch processor switchover is initiated from a console port, some commands might still be able to be entered from a connection through a Telnet or a vty session.
Workaround: Wait until the switchover is complete before issuing any commands from a vty port.
•CSCdp31368
Symptom: The arp timeout interface command disappears from the running configuration after a reboot.
Workaround: Upgrade to Cisco IOS Release 12.0(5)W5(13b) or a later release.
•CSCdp30288
Symptom: The following message is sometimes seen:
Received malformed TLV
Workaround: None; this message is harmless.
•CSCdp29185
Symptom: Some VCs remain DOWN after NVRAM configuration on system reload.
Workaround: The ping succeeds only if the PVC is deleted and re-installed.
•CSCdp23213
Symptom: After a switch processor switchover, input/output packet counters have an invalid value.
Workaround: None.
•CSCdp20982
Symptom: The FDL configuration on an IMA interface is not restored after an OIR of the port adapter.
Workaround: Reconfigure the FDL after an OIR.
•CSCdp20865
Symptom: Performing a shutdown/no shutdown command sequence on an ARM interface, especially when it has configured a large number of LANE clients, might cause an error message like this to appear:
%LANE-3-LANE_ERROR: lecs finder: ILMI hung on interface ATM1/0/0
It indicates an internal timeout occurred. It should try to self-cover and not affect any normal operations.
Workaround: None.
•CSCdp20230
Symptom: Software forced crash in logger_buffer_init.
Workaround: None.
•CSCdp16253
Symptom: The loopback configured on an ATM interface is retained even after that interface becomes a member of an IMA group.
Workaround: Enter a no ima command on the interface, followed by a no shutdown command to bring up the ATM interface. The loopback can be disabled now. Enter the shutdown command on the ATM interface and configure the interface as a member of an IMA group.
•CSCdp15454
Symptom: PNNI load balances connections among alternate paths to a common destination as long as they have the same cumulative admin weight or other cost. However, load balancing currently only takes place among alternate paths with the same number of hops.
Workaround: Configure background route computations. For soft-vcs, explicit paths can be used to manually load balance some connections on longer paths.
•CSCdp15220
Symptom: ASP failed in power-on diagnostics with ws-x5165 installed.
Workaround: If config-reg has to be 0x2101: insert a Flash PC card in either slot 0 or slot1 when reloading the cat5500, OR Set the config-reg to 0x2102.
•CSCdp14004
Symptom: In rare instances, a Catalyst 8510 CSR takes a software forced crash at a program counter value of 0x6004A4D64 when running Cisco IOS Release 12.0(1a)W5(6f). Because the conditions which trigger this crash are not currently known, it is strongly advised that the router be configured to write a core dump if such an instance happens.
Workaround: None.
•CSCdp04109
Symptom: The debug ncdp packets, debug ncdp errors, and debug ncdp events commands do not display any information when you access the switch through the Ethernet port.
Workaround: Access the switch using the console port.
•CSCdp03740
Symptom: Soft-VCs sometimes come up without ILMI active.
Workaround: None.
•CSCdm94019
Symptom: Under certain circumstances, the switch router might display inaccurate traffic statistics on NNI or UNI interfaces.
Workaround: None.
•CSCdm92990
Symptom: Despite having enough bandwidth, Resource Management might reject some
soft PVCs.Workaround: None.
•CSCdm91060
Symptom: The ILMI keepalive feature resets the interface on the second retry following a link failure. This behavior might occur despite having configured the system to allow up to five retries.
Workaround: None.
•CSCdm89519
Symptom: The Digital Crossconnect Unit (DCU) on the T1/E1 CES port adapter might malfunction unexpectedly.
Workaround: None.
•CSCdm87397
Symptom: On the Catalyst 8540 CSR running the W5(11) code or lower, adding logging source-interface and then removing logging source-interface might stop syslogs being sent out on Ethernet 0 (the management port). Syslogs continue to be sent out through the regular interface module ports.
Workaround: Do not configure the source-interface. If you configure the source-interface, do not remove the logging source interface. Rebooting the switch router resolves the state. An error syslog (LINK-3-UPDOWN) also corrects the problem.
•CSCdm80806
Symptom: Under certain conditions, the ATM link on an IMA port adapter might come up when the other end has been shut down.
Workaround: None.
•CSCdm80628
Symptom: A T1 CES interface does not send out a remote alarm indication (RAI) in the reverse direction upon detecting an alarm indication signal (AIS).
Workaround: None.
•CSCdm80015
Symptom: Under certain conditions, the line code violation (LCV) counter on an IMA port adapter might not be updated.
Workaround: None.
•CSCdm77939
Symptom: Under certain conditions, the ATM link on an IMA port adapter might come up with a different framing mode.
Workaround: None.
•CSCdm77907
Symptom: Under certain conditions, the ATM link on an IMA port adapter might come up with different line codes at both ends.
Workaround: Use the show controller command to list line code violations occurring on the line. Then use the shutdown command on the interface to clear the counter. Use the no shutdown command to reenable the interface.
•CSCdm60387
Symptom: On a router with a rev-B1 fast Ethernet interfaces, there is no way to turn off time-stamp refresh during destination address lookup. A source address is learned on a port in the initial spanning tree state. After the port goes into blocking state, a destination address lookup on the received packet keeps the entry alive. This is particularly true where the source and destination address are the same, as in the case of keepalive packets.
Workaround: None. This problem does not occur in routers with fast Ethernet interfaces later than rev-B1.
•CSCdm58868
Symptom: Following a system reload, the OC-3c and OC-12c port adapters come up without a problem. If a new module is inserted after the reload, the module is recognized but none of the ports send out any information. The input cell count increments, but the output cell count does not increment.
Workaround: None.
•CSCdm56393
Symptom: After resetting an ATM interface, the soft VCs terminating on that interface might not come up for certain VPI/VCI values.
Workaround: None.
•CSCdm52827
Symptom: Issuing the atm snoop interface command might cause the FC1 system to fail unexpectedly.
Workaround: None.
•CSCdm48886
Symptom: The switch router does not support a PVP tunnel with a VPI value of 0. The IOS relates subinterface 0 to the main interface so interface ATM x/y/z.0 represents the main interface ATM x/y/z. If the user attempts to create a PVP tunnel with a VPI value of 0, the system should return an error on interface ATM x/y/z.0.
Workaround: None.
•CSCdm46569
Symptom: For the 12.0(7)W5(15c) release, the units for the atm soft vc command are not backwards-compatible with the 12.0(4a)W5(11a) release.
Workaround: None.
•CSCdm43851
Symptom: When polling the sysObjectID of a Catalyst 8510, it returns 190, which is the sysObjectID of a Catalyst 8510 CSR. This situation causes a problem in CiscoWorks for Switched Internetworks (CWSI), because the MSR has ATM interfaces. By mistaking an MSR for a CSR, ATMDirector will not work with the Catalyst 8510.
Workaround: None.
•CSCdm44497
Symptom: On a PNNI signaling link, the Promina 4000 NET switch sends a message that prompts the system to send a CALL PROCEEDING message and then a RELEASE message with a cause code 8a ("VPCI/VCI unacceptable"). When the call goes out on a uni3.1 interface, this cause code should be mapped to VPI/VCI assignment failure. This mapping does not occur for PNNI links.
Workaround: None.
•CSCdm40533
Symptom: The device might lose its IP OSPF neighbor information and connections over a BVI interface after a few days of running, requiring a system reboot.
Workaround: None.
•CSCdm36800
Symptom: The CES ABCD bits are not user configurable when a fault occurs.
Workaround: None.
•CSCdm36790
Symptom: When forwarding a call setup from one VP tunnel to another, the switch router might drop certain information elements that are considered mandatory. This problem might cause compatibility problems with third-party equipment.
Workaround: None.
•CSCdm36745
Symptom: Configuring a channelized E1 (CE1) Frame Relay 2.048-Mbps ATM port adapter for clear E1 might cause the line code violation and LES counters to increment continually.
Workaround: None.
•CSCdm34634
Symptom: The soft PVC count might not be included in atmfAtmLayerConfiguredVCCs.
Workaround: None.
•CSCdm36648
Symptom: The device might lose IPX connectivity over a BVI interface, requiring the use of the clear ipx route* command to reestablish connectivity.
Workaround: None.
•CSCdm35971
Symptom: After executing an IPX ping with a timeout value of zero, subsequent IPX pings on the device will fail.
Workaround: None.
•CSCdm32706
Symptom: When a large number of bridge groups or bridge group members are configured and IRB is enabled on the devices, reloading one of the devices or configurations might lead to high route processor utilization. The side effect of this is temporary spanning-tree loops, leading to AAL5 buffer exhaustion problems.
Workaround: In this case, if IRB is enabled, you might need to increase the number of buffers on the device using the aal5 buffers command.
•CSCdm32506
Symptom: When entering the show running-config command, the switch router might fail unexpectedly due to a bus error.
Workaround: None.
•CSCdm29650
Symptom: Incorrect coding of the information element "call state."
Information element "call state" incorrectly sets the coding standard to 00 (ITU-T coding standard) instead of 11 as specified in the PNNI specification. This can cause compatibility problems with other vendors' implementations.
Workaround: None.
•CSCdm29529
Symptom: When soft VCs and PVCs on the same interface module or port adapter have more than one VCI configured, it is not possible to use a VCI value higher than 8191 on the LightStream 1010 ATM switch.
Workaround: Use VCI values lower than 8192.
•CSCdm29503
Symptom: The advertised priority is not updated for PGL if configured to match the advertised priority.
Workaround: None.
•CSCdm28633
HSRP MAC appears as a REMOTE entry in the CAM table for an ACTIVE router.
Symptom: When a peer switch with UPLINK FAST enabled is connected to a Catalyst 8500 bridge group interface, the virtual MAC address of HSRP for an ACTIVE device in one of the member interfaces of the bridge group is programmed as a REMOTE entry.
Workaround: Use the clear bridge command to update the CAM table.
•CSCdm26948
Removing adjacencies when bridge entry ages might lead to high route processor utilization.
Symptom: Adjacencies are removed when a bridge table entry ages out. This causes traffic to be routed to the route processor, which might lead to high route processor utilization.
Workaround: Set the ARP timeout value to be less than the bridge age timer.
•CSCdm25943
CPUHOG messages appear on a 16 EtherChannel subinterface configuration.
Symptom: With 16 or more subinterfaces on a port channel, the following configuration might cause CPUHOG messages to appear:
[no] ip routing
[no] ipx routing
[no] bridge irb
[no] bridge-g [bridge-group-no]
Workaround: No workaround is needed; the route processor HOG messages should not affect the functionality of the device.
•CSCdm23579
Symptom: The switch rejects calls with extended QoS parameters.
When ATM QoS for cdv is configured and you specify a soft VC (whether CBR or VBR-RT) from a UNI port which has negotiated a UNI 4.0 connection, this soft VC does not come up.
Workaround: None.
•CSCdm20257
Symptom: Under certain circumstances, the lane server-bus ethernet command might cause the following exception:
Unexpected exception, CPU signal 10, PC = 0x605CB430
Workaround: None.
•CSCdm19670
Symptom: 1CT3 and 4CE1 do not support DS1 MIB (RFC 1406). Also, 1CT3 does not support DS3 MIB (RFC 1407).
Workaround: None.
•CSCdm19073
Symptom: The granularity of the switch rate scheduler is such that rates are rounded down (when converting from bits per second to cells per second) when in fact they should be rounded up.
Workaround: None.
•CSCdm19018
Symptom: When a call setup traverses a switch running PNNI on the ingress side and IISP (3.0 or 3.1) on the egress side, the message might be corrupted.
Workaround: None.
•CSCdm15900
Symptom: The switch uses backward parameters in QoS IE for PtMP calls. This might cause incompatibility with other vendors' implementations.
Workaround: None.
•CSCdm11577
Symptom: The atm soft-vc command does not disable OAM intercept.
Workaround: When the ordering of OAM cells must be preserved in the cell-flow, OAM intercept must be disabled. Using the atm soft-vc command to disable this does not work for soft PVCs.
•CSCdm08234
Symptom: CES (CBR) might show the interface as up while in loss of signal (LOS). Also, it does not send AIS while the interface is shut down or after the uplink ATM has been broken (when configured as structured mode).
Workaround: None.
•CSCdm07874
Symptom: In release 11.3 on the Ibis port adapter, you cannot exceed the number of leaves in a p2mp connection beyond 32.
Workaround: None.
•CSCdm06168
Symptom: The switch router does not accept PVCs terminating on their CPU port over point-to-point subinterfaces.
Workaround: None.
•CSCdm04013
Symptom: AAL5 CRC errors are not accounted for at the physical interface. The show atm interface command does not display CRC errors seen at the physical interface level. These errors are not logged under AAL5 CRC.
Workaround: None.
•CSCdk93048
Formatting information is lost if an IOS image is downloaded to slot 0.
Symptom: When downloading an IOS image to the slot 0 Flash memory card on the Catalyst 8510 CSR by way of SNMP, the copy operation fails with a "copyUnknownFailure" message, and the formatting information on the Flash memory card is lost.
Workaround: When downloading an IOS image by way of SNMP, such as with the SWIM (Software Image Management) application of CiscoWorks2000, always use slot 1 instead of slot 0 as the target location of the IOS image.
•CSCdk90147
Symptom: A crash might occur while removing subinterfaces using the no interface command.
Workaround: None.
•CSCdk90091
Symptom: A software crash might occur on the switch running software release 11.2(15)WA3(6). The crash is related to PNNI; the crashing function is pnni_link_av.
Workaround: None.
•CSCdk89275
The show controllers command can bring down an interface.
Symptom: Occasionally, the show controllers interface-name command can bring down an interface and the line protocol. The condition that leads to this scenario is random and very infrequent. The end result is that routing/bridging stops on this interface.
Workaround: None.
•CSCdk88859
Symptom: The Frame Relay port adapter firmware might report CRC errors on a PVC if it receives traffic using the same VPI/VCI/DLCI as the PVC being configured. The errors only occur while the firmware is still configuring the VC. Once the PVC has been configured, the CRC errors are discontinued. Since the frames appear like zero-length AAL5 packets while the firmware is still configuring the VC, the firmware does not increment discard bytes, but only increments discard frames due to the CRC error counter.
Workaround: Do not allow traffic to pass on the VC while it is being configured on the port.
•CSCdk87959
Symptom: The switch router sends acctngFileFull trap every 10 seconds if the snmp-server enable trap atm is included in the configuration.
Workaround: Remove the snmp-server enable trap atm command from the configuration or use the no atmacct-deb command to turn off the sending of the misinforming trap.
•CSCdk84355
Symptom: Some ports on an ATM25 port adapter might on occasion go into an alarm state. Under certain conditions the ATM25 port adapter might go into an alarm state as indicated by the red LED on the port adapter.
Workaround: None.
•CSCdk84269
Symptom: TR-LEC currently processes all registration requests received on its control distribute VC. It should only be doing this if the LEC id in the registration message matches up with its own LEC id.
Workaround: None.
•CSCdk82832
The scheduler allocate command is not supported on the Catalyst 8500 CSR.
Symptom: Unpredictable results might occur if the route processor scheduler allocation is changed in the configuration file.
Workaround: Remove the scheduler allocate command from the configuration file. We recommend that you do not change the default values for this command.
•CSCdk73492
Route processor HOG message appears when activating OSPF on a large port channel configuration.
Symptom: A route processor HOG message appears when OSPF is activated on a port channel interface with more than 30 subinterfaces.
Workaround: The operation succeeds even if this message appears. No action is necessary.
•CSCdk72837
The default spanning tree path cost is incorrect on Gigabit Ethernet interfaces.
Symptom: Path costs on Gigabit Ethernet interfaces shown by the show span command do not match the expected default value of 100.
Workaround: Set the path costs manually. One option would be to set the path cost for Gigabit EtherChannel (GEC) ports to 1 and set the path cost for the non-GEC ports to 2.
•CSCdk82708
Symptom: When running tag switching, no tag is created for the default route.
Workaround: None.
•CSCdk79426
Symptom: Soft VPs and PVPs cannot coexist due to VPI allocation errors.
Workaround: None.
•CSCdk78881
Symptom: On a switch router running release 11.3(3a)WA4(6), if an atm ping command is entered after a VC is removed via a link failure, a bus error might cause the system to fail unexpectedly.
Workaround: Reload the system via power reset.
•CSCdk78469
Symptom: PNNI does not clean up and release some of its data structures properly, following process termination. A PNNI process is terminated when the associated node is either disabled or removed. As a result of not freeing the data structures, the associated memory is lost until the next reload.
Workaround: None.
•CSCdk77032
Symptom: The PNNI SNMP agent is not able to discover and allow PNNI-related configurations on ATM subinterfaces. An alignment error message is printed when an SNMP walk (or other SNMP get next) request is issued.
Workaround: None.
•CSCdk76280
Symptom: Connections with end-to-end delay IE included in the connect message might fail. Examples of these connections include UNI40, CBR, UBR-RT. When a switch router that is an intermediate switch passes a bad CONNECT message from one side to the other, the CONNECT message shows up as a CONNECT packet that is longer than the actual contents, with junk bytes at the end.
Workaround: None.
•CSCdk73733
Symptom: Power-on diagnostics will display an NVRAM-Config failure following the second power-cycle after you use the write erase command if the write memory command has not been used between power-cycles.
This failure will occur only if you use the write erase command and the power-on diagnostics runs twice without the write memory command being used.
Note Power-on diagnostics run only if the switch is powered on. Power-on diagnostics do not run when using the reload command.
Workaround: After using the write erase command, use the write memory command before power cycling the switch.
•CSCdk73583
Symptom: A switch router with 8 LAN emulation clients configured on the CPU, and 300 point-to-point and 60 point-to-multipoint connections could crash unexpectedly due to an infinite loop.
Workaround: None.
•CSCdk69639
Symptom: Disabling tag switching on an interface that carries tagged VCs (TVCs) does not remove the TVCs. Reenabling tag switching on that interface will put it in the "not TDP ready" state.
Workaround: None.
•CSCdk63547
Symptom: Frame Relay soft VC configuration is not possible using SNMP. You cannot configure Frame Relay soft VCs using the casfVcEndptTable in SNMP.
Workaround: None.
•CSCdk62547
Symptom: The DS1 MIB objects do not work for T1/E1 ATM cards.
Workaround: None.
•CSCdk56557
Symptom: Spurious memory access on show ip route command when SONICT interface is shutdown.
If you shutdown a 10-Mbps port and then use the show ip route command, spurious memory access appears in the print_route_preamble():
Workaround: None.
•CSCdk52436
Symptom: On a switch router configured with 32 MB RAM, IPC traffic between the port adapter driver and the firmware can experience a transient failure when the port adapter firmware crashes under heavy traffic conditions. The port adapter recovers from this transient failure if it is reset after waiting for about 2 minutes.
This IPC failure, which is due to an unexpected firmware crash under a heavy load, does not occur on a system configured with 64MB of RAM.
Workaround: None.
•CSCdk49213
Symptom: Frame Relay soft VC is not released when the line protocol goes down.
When the Local Management Interface (LMI) configured on a Frame Relay interface brings down the line protocol of that interface, the soft PVCs originating from or terminating on that Frame Relay interface are not torn down.
Workaround: None.
•CSCdk47516
Symptom: Tag switching and Tag Discovery Protocol (TDP) memory fragmentation. While running tag switching with a very large number of destinations, continuous toggling of VC Merge (which forces all the TDP sessions to restart) on the switch for a very long period of time (for example, overnight) causes memory fragmentation in the TDP process.
Workaround: None.
•CSCdk42052
Symptom: When loading a software image version 11.3 or later on a switch router with a software image version 11.2 or earlier, LEC and other LANE components might fail to come up if they are configured using an ATM address whose first 19 bytes are the same as the active ATM address of the switch.
The ATM address of the switch along with the first 128 values for its selector byte should be reserved for use by PNNI. Starting with the 11.3 software version, PNNI supports hierarchy and registers an ATM address for all PNNI nodes using the switch ATM address with various selector byte values.
Workaround: If LANE components fail to come up because their ATM addresses conflict with the reserved ATM addresses for PNNI, reconfigure the LANE components using different addresses. It is recommended that LANE applications use the addresses shown by the show lane default-atm-addresses command, which eliminates this problem.
•CSCdk41001
Symptom: The show controller atm card/subcard/port command displays the incorrect interface type after hot swapping the port adapter.
Workaround: None.
•CSCdk33601
Symptom: ADD Party over Tunnel does not work.
On a source node, if you are adding a subsequent leaf to a VP tunnel that is out of bandwidth, PNNI might reject the route request (for the leaf) leading to an eventual rejection of the ADD party by signaling.
Workaround: None.
•CSCdk27725
Symptom: Snooping error:
%ATMCORE-3-INTERNAL_ERROR:connUpdateFreeVxiMap:bitMapInfo
When snoop-VC is configured on a port the switch returns this internal error message:
%ATMCORE-3-INTERNAL_ERROR: connUpdateFreeVxiMap: bitMapInfo null ptr
Workaround: This message can be ignored; it does not affect the snooping functionality.
•CSCdk26482
Symptom: When using the show atm interface resource atm card/subcard/port.subport command, the following error message appears:
Tunnel:%ATMCORE-3-INTERNAL_ERROR: show_atm_int_rm: Cannot find phylo
This error message appears because the tunnel specified in the CLI has been deleted and the software has released all the structures pertaining to that tunnel.
Workaround: None.
•CSCdk25256
Symptom: A non-zero generic flow control (GFC) field is not reset to zero when passing through the switch router.
When cells with a non-zero GFC field are received on a PVC, they are switched on the exit port without changing the GFC field. The switch should reset to zero all GFC bits from cells received with non-zero GFC at the user network interface (UNI).
Workaround: None.
•CSCdk22791
Symptom: When a large amount of data is sent out of the Ethernet interface, the interface can become overwhelmed and start generating the following error message:
%SONICT-3-INTERNAL_ERROR: sonic_send: no free tbufs
The interface stops sending data and the transmitter remains stuck until a shutdown command followed by a no shutdown command sequence is entered on the interface.
Workaround: None.
•CSCdk22484
Symptom: ATM Accounting: Exception in validblock_diagnose because resources at destination switch were not available for soft VC setup.
Workaround: None.
•CSCdk17977
Symptom: A third party vendor, when running UNI 4.0, cannot connect a VC to a Cisco router running UNI 3.1 by way of a Catalyst 8510 or a LightStream 1010 ATM switch.
Workaround: None.
•CSCdk07378
Symptom: Funnel VCs can jeopardize quality of service (QoS) for services.
The current multipoint-to-point funnel implementation can compromise the QoS guarantees of other connections (guaranteed services) when the application that created the funnel SVC malfunctions. For example, if the application were to transmit traffic on more than one leg of the funnel SVC simultaneously, the rate scheduler on the output interface oversubscribes and, potentially, affects the peak cell rate (PCR), sustained cell rate (SCR), and maximum cell rate (MCR) guarantees for other VCs on the interface.
Workaround: None.
•CSCdk03049
Symptom: The show atm vc interface vpi vci command displays incorrect transmit (TX) cell counter values on the VC-merged leg of the connection.
Workaround: None.
•CSCdj85853
Symptom: When you set the ROM monitor environment variable boot to a nonexistent file (using the Cisco IOS command boot system flash) and the configuration register is set to 0x2102 (autoboot), the switch hangs during the subsequent reload command issued by the software.
Workaround: Power-cycle the switch; a break character is sent to the switch to force it to the ROM monitor prompt. You can then manually reboot the switch.
•CSCdj84981
Symptom: After hot swapping an OC-3 LR port adapter with an OC-3 MM port adapter, the system might fail unexpectedly.
Workaround: None.
•CSCdj84379
Symptom: The granularity provided by the FC-PFQ feature card scheduling hardware does not allow an exact match of all requested cell rates. To satisfy the traffic contract guarantee, the next higher available scheduling value is used. A shaped VP tunnel is used frequently to pass data to a WAN VP trunk, and limits the traffic transmission to the scheduled rate. This can cause cells to be dropped in the WAN. It might be better to do any dropping prior to multiplexing onto the VP, so that a packet discard can be performed. Packet discard cannot be performed on the VP trunk.
Workaround: None.
•CSCdj84344
Symptom: There is a small divergence in the measured output of the shaped VP tunnels at rates of 90 Mbps and above.
Workaround: None.
•CSCdj82930
Symptom: Open shortest path first (OSPF) does not recognize more than four parallel interfaces. This might cause some tag switching VCs (TVCs) to not get switched to other interfaces if a tunnel carrying the TVCs is shut down.
Workaround: Enter a clear ip route command on the switch on the interface that was shut, or a clear ip route command on all the switches to bring everything back up. If the clear ip route command does not bring everything back up, enter a shutdown/no shutdown command sequence on the UNI interfaces of the switch that had the closed physical interface.
•CSCdj80396
Symptom: While setting up a large number of calls, the system generates the following error message:
%SYS-3-CPUHOG: Task ran for 5852 msec (0/0), process = Exec, PC = 6008DBB4
Workaround: None.
•CSCdj71876
Symptom: Under some rare conditions (not yet identified), some ports might get stuck in the WaitDevType state.
Workaround: Reboot the switch.
•CSCdj71109
Symptom: The ATM switch does not currently support maxvc-number negotiation through ILMI.
Workaround: None.
•CSCdj68412
Symptom: If there are multiple parallel paths to the same destination on a switch router with a FC-PFQ feature card installed, the tag switching VCs (TVCs) should be load balanced on a per network prefix basis over these parallel paths (up to a maximum of 4 parallel paths) instead of being VC merged. Load balancing does not happen in some cases and the TVCs might be VC merge and go out of the switch as a single VC.
Workaround: None.
•CSCdj54954
Symptom: On a switch router equipped with an FC-PFQ, the maximum number of cells available for use is 64,511. The number of cells in the switch fabric is 65,535.
Workaround: None.
•CSCdj47998
Symptom: The Catalyst 8510 Ethernet or LightStream 1010 ATM switch does not receive CDP multicast packets. However, the switch router does send out CDP multicast packets.
Workaround: None.
•CSCdj42967
Symptom: When memory is almost or completely exhausted and a soft PVC goes down, it might not come back up, leaving it in a releasing or inactive state.
Workaround: None.
•CSCdj31762
Symptom: SNMP SET to a CES port causes the switch to hang.
If you attempt to do an SNMP SET on the ifAdminStatus of a virtual ATM port associated with a CES card, the switch stops working.
Workaround: None.
•CSCdj25772
Symptom: Cell loss might occur while hot swapping a power supply.
Workaround: None.
•CSCdj18678
Symptom: SNMP support of the ciscoAtmIfPhysEntryData table and LED information is not available on the 25-MB port adapter.
Workaround: None.
•CSCdj13565
Symptom: ATM RMON data collection is not supported on subinterfaces or tunnels. The atm rmon collect command is accepted on hardware interfaces only; it is ignored on subinterfaces. SNMP and NVGEN support (via PortSelTable) is not possible until the interface's MIB (RFC 1573) entries are added for tunnel subinterfaces. ATM RMON counters for a hardware interface do not include any of the traffic through tunnels configured on the interface.
Workaround: None.
•CSCdj11070
Symptom: When disabling the Cisco Discovery Protocol (CDP) on an ATM interface that has been configured as a LEC, the CDP configuration is not saved to NVRAM.
Workaround: None.
•CSCdj10889
Symptom: The call attempt counters for PortSelectGroups might not count the outgoing calls on its NNI interfaces because of switch crankback attempts. This might result in a discrepancy between the call attempt counters shown on PortSelectGroups representing the interface on which the call came in and the counters shown on the PortSelectGroups representing the interface over which an attempt was made to forward the call. This problem might occur when a call fails.
Workaround: None.
•CSCdj01757
Symptom: When one of the installed power supplies is powered OFF, and you are copying an image to bootflash, a power supply failure message appears.
Workaround: None.
•CSCdj01016
Symptom: You can create variable bit rate (VBR), available bit rate (ABR), and unspecified bit rate (UBR) VCs across the switch with peak cell rate (PCR) values greater than the interface line rate. However, the actual allocated bandwidth continues to be:
–VBR: sustained cell rate (SCR) + sustained-cell-rate-margin-factor x (PCR - SCR).
–ABR, UBR: no bandwidth is allocated.
Workaround: None.
•CSCdi92142
Symptom: A LECS, using Cisco IOS Version 11.2(X), expects all LESs to establish an individual control VC to the LECS in order to validate clients.
If different emulated Local Area Networks (ELANs), using Cisco IOS Release 11.1(X), are configured on multiple subinterfaces of the same physical interface, then all LESs multiplex the control messages (which validate the clients) into a single VC.
For example, see the following LES router configuration:
atm1/0.1 sysa_70k_31_a1.1_LAN sysa_70k_31_a1.1_LAN
atm1/0.2 sysa_70k_31_a1.2_LAN sysa_70k_31_a1.2_LAN
atm1/0.3 sysa_70k_31_a1.3_LAN sysa_70k_31_a1.3_LAN
atm1/0.4 sysa_70k_31_a1.4_LAN sysa_70k_31_a1.4_LAN
This configuration of an LECS sends the following warning messages to the console stating that an LES of one ELAN is attempting to obtain information about another ELAN:
%LANE-4-LECS_WARNING: interface ATM2/0/0: elan 'sysa_70k_31_a1.4_LAN' LES asking for elan
'sysa_70k_31_a1.1_LAN'
%LANE-4-LECS_WARNING: interface ATM2/0/0: elan 'sysa_70k_31_a1.4_LAN' LES asking for elan
'sysa_70k_31_a1.2_LAN'
%LANE-4-LECS_WARNING: interface ATM2/0/0: elan 'sysa_70k_31_a1.4_LAN' LES asking for elan
'sysa_70k_31_a1.3_LAN'
The clients are still allowed to join the ELAN. Disregard the warning messages.
Workaround: None.
•CSCdi82954
Symptom: The receiver circuitry on DS3 port adapters can interpret noise as a valid signal. This signal is framed incorrectly and does not contain real data. The DS3 controller interprets the signal as a bad signal instead of no signal, and the red RX LED lights up.
Workaround: None.
•CSCdi75584
Symptom: Under very heavy traffic conditions the switch might experience temporary queue cell failures. This should clear after the traffic congestion clears.
Workaround: None.
•CSCdi74229
Symptom: When more than 1000 SVCs are active on an interface and the shutdown command is entered, all SVCs on that interface are released and the following message appears:
%SYS-3-CPUHOG
This message indicates that the release process runs for a long time before returning control to the kernel, which can then schedule other tasks. This process does not affect normal operation of the switch.
Workaround: None.
•CSCdi55937
Symptom: Remote defect identification (RDI) cells sent by an end point in response to alarm indication signal (AIS) cells generated at an intermediate switch with a fault condition on an interface are not propagated beyond the intermediate switch. The intermediate switch removes the connection leg entries for both interfaces participating in the connection when a fault is discovered on one of the interfaces, even though the other interface might still be up. As a result, the RDI cells are dropped at the intermediate switch.
Workaround: None.
Interoperability
Starting with the following software releases, hardware and software functionality interoperability exists between CSR interface modules and MSR interface modules by way of the ATM router module on the MSR chassis running an MSR image:
•Cisco IOS Release 12.0(10)W5(18b) supports interoperability between CSR interface modules and MSR interface modules by way of the ATM router module on the Catalyst 8510 MSR running an MSR image.
Y2K Compliance
Related Documentation
The following sections describe the documentation available for the Catalyst 8510 and the LightStream 1010 ATM switch. Typically, these documents consist of hardware installation guides, software installation guides, Cisco IOS configuration and command references, system error messages, and feature modules, which are updates to the Cisco IOS documentation. Documentation is available as printed manuals or electronic documents, except for feature modules, which are available online only.
The most up-to-date documentation can be found on the Web through Cisco.com and the Documentation CD-ROM. These electronic documents might contain updates and modifications made after the hard-copy documents were printed.
These release notes should be used in conjunction with the documents listed in the following sections:
Platform Documents
The following list includes the platform-specific documentation available for the Catalyst 8510 and the LightStream 1010 ATM switch:
•Quick Reference Catalyst 8510 and LightStream 1010 Hardware Information
•ATM and Layer 3 Module Installation Guide
Software Documents
The following list includes the software documentation available for the Catalyst 8510 and the LightStream 1010 ATM switch:
•ATM and Layer 3 Switch Router Command Reference
•ATM and Layer 3 Quick Software Configuration Guide
•ATM Switch Router Configuration Guide
•Layer 3 Switching Software and Feature Configuration Guide
•Troubleshooting Guide
Obtaining Documentation
Cisco documentation and additional literature are available on Cisco.com. Cisco also provides several ways to obtain technical assistance and other technical resources. These sections explain how to obtain technical information from Cisco Systems.
Cisco.com
You can access the most current Cisco documentation at this URL:
http://www.cisco.com/univercd/home/home.htm
You can access the Cisco website at this URL:
You can access international Cisco websites at this URL:
http://www.cisco.com/public/countries_languages.shtml
Ordering Documentation
You can find instructions for ordering documentation at this URL:
http://www.cisco.com/univercd/cc/td/doc/es_inpck/pdi.htm
You can order Cisco documentation in these ways:
•Registered Cisco.com users (Cisco direct customers) can order Cisco product documentation from the Ordering tool:
http://www.cisco.com/en/US/partner/ordering/index.shtml
•Nonregistered Cisco.com users can order documentation through a local account representative by calling Cisco Systems Corporate Headquarters (California, USA) at 408 526-7208 or, elsewhere in North America, by calling 800 553-NETS (6387).
Documentation Feedback
You can send comments about technical documentation to bug-doc@cisco.com.
You can submit comments by using the response card (if present) behind the front cover of your document or by writing to the following address:
Cisco Systems
Attn: Customer Document Ordering
170 West Tasman Drive
San Jose, CA 95134-9883We appreciate your comments.
Obtaining Technical Assistance
For all customers, partners, resellers, and distributors who hold valid Cisco service contracts, Cisco Technical Support provides 24-hour-a-day, award-winning technical assistance. The Cisco Technical Support Website on Cisco.com features extensive online support resources. In addition, Cisco Technical Assistance Center (TAC) engineers provide telephone support. If you do not hold a valid Cisco service contract, contact your reseller.
Cisco Technical Support Website
The Cisco Technical Support Website provides online documents and tools for troubleshooting and resolving technical issues with Cisco products and technologies. The website is available 24 hours a day, 365 days a year at this URL:
http://www.cisco.com/techsupport
Access to all tools on the Cisco Technical Support Website requires a Cisco.com user ID and password. If you have a valid service contract but do not have a user ID or password, you can register at this URL:
http://tools.cisco.com/RPF/register/register.do
Submitting a Service Request
Using the online TAC Service Request Tool is the fastest way to open S3 and S4 service requests. (S3 and S4 service requests are those in which your network is minimally impaired or for which you require product information.) After you describe your situation, the TAC Service Request Tool automatically provides recommended solutions. If your issue is not resolved using the recommended resources, your service request will be assigned to a Cisco TAC engineer. The TAC Service Request Tool is located at this URL:
http://www.cisco.com/techsupport/servicerequest
For S1 or S2 service requests or if you do not have Internet access, contact the Cisco TAC by telephone. (S1 or S2 service requests are those in which your production network is down or severely degraded.) Cisco TAC engineers are assigned immediately to S1 and S2 service requests to help keep your business operations running smoothly.
To open a service request by telephone, use one of the following numbers:
Asia-Pacific: +61 2 8446 7411 (Australia: 1 800 805 227)
EMEA: +32 2 704 55 55
USA: 1 800 553 2447For a complete list of Cisco TAC contacts, go to this URL:
http://www.cisco.com/techsupport/contacts
Definitions of Service Request Severity
To ensure that all service requests are reported in a standard format, Cisco has established severity definitions.
Severity 1 (S1)—Your network is "down," or there is a critical impact to your business operations. You and Cisco will commit all necessary resources around the clock to resolve the situation.
Severity 2 (S2)—Operation of an existing network is severely degraded, or significant aspects of your business operation are negatively affected by inadequate performance of Cisco products. You and Cisco will commit full-time resources during normal business hours to resolve the situation.
Severity 3 (S3)—Operational performance of your network is impaired, but most business operations remain functional. You and Cisco will commit resources during normal business hours to restore service to satisfactory levels.
Severity 4 (S4)—You require information or assistance with Cisco product capabilities, installation, or configuration. There is little or no effect on your business operations.
Obtaining Additional Publications and Information
Information about Cisco products, technologies, and network solutions is available from various online and printed sources.
•Cisco Marketplace provides a variety of Cisco books, reference guides, and logo merchandise. Visit Cisco Marketplace, the company store, at this URL:
http://www.cisco.com/go/marketplace/
•The Cisco Product Catalog describes the networking products offered by Cisco Systems, as well as ordering and customer support services. Access the Cisco Product Catalog at this URL:
http://cisco.com/univercd/cc/td/doc/pcat/
•Cisco Press publishes a wide range of general networking, training and certification titles. Both new and experienced users will benefit from these publications. For current Cisco Press titles and other information, go to Cisco Press at this URL:
•Packet magazine is the Cisco Systems technical user magazine for maximizing Internet and networking investments. Each quarter, Packet delivers coverage of the latest industry trends, technology breakthroughs, and Cisco products and solutions, as well as network deployment and troubleshooting tips, configuration examples, customer case studies, certification and training information, and links to scores of in-depth online resources. You can access Packet magazine at this URL:
•iQ Magazine is the quarterly publication from Cisco Systems designed to help growing companies learn how they can use technology to increase revenue, streamline their business, and expand services. The publication identifies the challenges facing these companies and the technologies to help solve them, using real-world case studies and business strategies to help readers make sound technology investment decisions. You can access iQ Magazine at this URL:
http://www.cisco.com/go/iqmagazine
•Internet Protocol Journal is a quarterly journal published by Cisco Systems for engineering professionals involved in designing, developing, and operating public and private internets and intranets. You can access the Internet Protocol Journal at this URL:
•World-class networking training is available from Cisco. You can view current offerings at this URL:
http://www.cisco.com/en/US/learning/index.html
This document is to be used in conjunction with the documents listed in the "Related Documentation" section.
CCIP, CCSP, the Cisco Arrow logo, the Cisco Powered Network mark, Cisco Unity, Follow Me Browsing, FormShare, and StackWise are trademarks of Cisco Systems, Inc.; Changing the Way We Work, Live, Play, and Learn, and iQuick Study are service marks of Cisco Systems, Inc.; and Aironet, ASIST, BPX, Catalyst, CCDA, CCDP, CCIE, CCNA, CCNP, Cisco, the Cisco Certified Internetwork Expert logo, Cisco IOS, the Cisco IOS logo, Cisco Press, Cisco Systems, Cisco Systems Capital, the Cisco Systems logo, Empowering the Internet Generation, Enterprise/Solver, EtherChannel, EtherFast, EtherSwitch, Fast Step, GigaDrive, GigaStack, HomeLink, Internet Quotient, IOS, IP/TV, iQ Expertise, the iQ logo, iQ Net Readiness Scorecard, LightStream, Linksys, MeetingPlace, MGX, the Networkers logo, Networking Academy, Network Registrar, Packet, PIX, Post-Routing, Pre-Routing, ProConnect, RateMUX, Registrar, ScriptShare, SlideCast, SMARTnet, StrataView Plus, SwitchProbe, TeleRouter, The Fastest Way to Increase Your Internet Quotient, TransPath, and VCO are registered trademarks of Cisco Systems, Inc. and/or its affiliates in the United States and certain other countries.
All other trademarks mentioned in this document or Website are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other company. (0403R)
Copyright © 2004 Cisco Systems, Inc. All rights reserved.
Posted: Sun Jun 6 18:00:38 PDT 2004
All contents are Copyright © 1992--2004 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.