This document contains the following sections:
Upon receipt of, and before opening the line interface module (LIM), inspect the package for any damage that might have occurred during shipping. If the package shows any signs of external damage or rough handling, notify your carrier's representative.
When unpacking the LIM be sure to keep all original packing materials. They might be needed for storing, transporting, or returning the product.
Note All products returned to Cisco, under warranty, must be packed in their original packing materials. |
The LIM package should include the following:
Caution All modules are susceptible to electrostatic discharge (ESD) even while installed. Take the necessary precautions to minimize electrostatic damage while handling modules. |
The LIM is designed to be installed into the CISCO 8110 LIM slots, and operates as the Line Interface for the different Line types supported by the CISCO 8110.
A standard CISCO 8110 configuration will include two LIMs. Each of these modules has handles for insertion or extraction from the unit. The third module, placed in the far-right-hand side slot is a hot standby module.
To connect the cables, use the following procedures:
Warning When LIM LIM-155SM-I ,LIM-155SM-L, LIM-155SM-XL, , LIM-155SM-I-SH, LIM-155SM-L-SH or LIM-155SM-XL-SH are used the CISCO 8110 is a Class 1 Laser Product Take the necessary precautions to avoid dangerous radiation hazards if these modules are not handled properly. |
To connect your CISCO 8110 unit optical interfaces:
Step 2 Snap the cables into the LIM ports on the front panel of your CISCO 8110 unit.
Step 3 Snap the other end of the cable into the ATM switch or other ATM equipment. Be sure that each cable connects to Tx on one end and Rx on the other.
Caution Electrical cables should be 26 AWG or lower. |
To connect your CISCO 8110 unit electrical BNC interfaces:
You may want to mark the ends of the cable so you can identify the wires.
Step 2 Attach the cables into the LIM ports on the front panel of your CISCO 8110 unit.
Step 3 Attach the other end of the cable into the ATM switch or other ATM equipment. Be sure that each cable connects to Tx on one end and Rx on the other.
To connect your CISCO 8110 unit electrical RJ-45 interfaces:
The RJ-45 pin out should be as follows:
T1/E1 Pinouts | UTP Pinouts | ||
---|---|---|---|
Pin | Signal | Pin | Signal |
1 | Rx Tip | 1 | Tx+ |
2 | Rx Ring | 2 | Tx- |
4 | Tx Tip | 7 | Rx+ |
5 | Tx Ring | 8 | Rx- |
Step 2 Attach the cables into the LIM ports on the front panel of your CISCO 8110 unit.
Step 3 Attach the other end of the cable into the ATM switch or other ATM equipment. Be sure that each cable connects to Tx on one end and Rx on the other.
Note Please make sure that the JMP1 pins are not shorted. This option (shorted JMP 1 pins) may be used only when using a coax cable. |
This section includes the following:
To install a LIM in your CISCO 8110:
Step 2 Place the module's card edges into the right and left module guides at the front of the CISCO 8110 Slide in the module until it makes contact with the backplane, then push firmly to mate the connectors solidly with the backplane.
Step 3 Secure the module's front panel to the CISCO 8110 chassis using the mounting screws on the right and left of the module's front panel.
Step 4 Securely install and fasten each module to facilitate the installation of the one next to it.
Step 5 Configure the module type to the actual LIM type, using the console or the in-band management application.
Step 6 Change the module state to active, using the console or the in-band management application.
To remove a LIM in your CISCO 8110:
Step 2 Unscrew the right and left mounting screws on the front panel of the module.
Step 3 Remove the module by pulling evenly its mounting screws.
Step 4 Use faceplate panels, supplied with the CISCO 8110 Unit to protect unused slots from dust and reduce electromagnetic radiation.
Caution The CISCO 8110 ventilation mechanism is not effective if empty slots are not covered with faceplate panels. |
Caution If you store modules outside the CISCO 8110 for an extended period of time, place them in the original packaging (or equivalent packaging providing ESD protection). |
When changing from one type of LIM to another (e.g. from STM-1 to E3) use the following procedure:
Step 2 Remove the module
Step 3 Insert the new LIM
Step 4 Change the LIM module type by using the console or the in-band management application.
Step 5 Change the module state to active, using the console or the in-band management application
LEDIndicator | Status | Explanation |
---|---|---|
ALM | On Off | Alarm present in LIM. No alarm in LIM. |
Tx | Off On Weak On Strong | No cells transmitted in LIM port. LIM transmitter enabled, no ATM cells transmitted. User cells are being transmitted. |
Rx | Off On Weak On Strong Flashing | No cells detected in LIM port. LIM synchronized to received signal. No ATM cells detected. Error during SelfTest |
NOTES:
1. OUT of SERVICE - all LEDs are off
2. ACTIVE MODE - Tx and Rx active (for no alarm)
3. ACTIVE MODE - Tx +ALM active (with alarm)
4. STANDBY MODE - All LEDs off (including ALM)
You can access the most current Cisco documentation on the World Wide Web at http://www.cisco.com, http://www-china.cisco.com, or http://www-europe.cisco.com.
Cisco documentation and additional literature are available in a CD-ROM package, which ships with your product. The Documentation CD-ROM is updated monthly. Therefore, it is probably more current than printed documentation. The CD-ROM package is available as a single unit or as an annual subscription.
Registered CCO users can order the Documentation CD-ROM and other Cisco Product documentation through our online Subscription Services at http://www.cisco.com/cgi-bin/subcat/kaojump.cgi.
Nonregistered CCO users can order documentation through a local account representative by calling Cisco's corporate headquarters (California, USA) at 408 526-4000 or, in North America, call 800 553-NETS (6387).
Cisco provides Cisco Connection Online (CCO) as a starting point for all technical assistance. Warranty or maintenance contract customers can use the Technical Assistance Center. All customers can submit technical feedback on Cisco documentation using the web, e-mail, a self-addressed stamped response card included in many printed docs, or by sending mail to Cisco.
Cisco continues to revolutionize how business is done on the Internet. Cisco Connection Online is the foundation of a suite of interactive, networked services that provides immediate, open access to Cisco information and resources at anytime, from anywhere in the world. This highly integrated Internet application is a powerful, easy-to-use tool for doing business with Cisco.
CCO's broad range of features and services helps customers and partners to streamline business processes and improve productivity. Through CCO, you will find information about Cisco and our networking solutions, services, and programs. In addition, you can resolve technical issues with online support services, download and test software packages, and order Cisco learning materials and merchandise. Valuable online skill assessment, training, and certification programs are also available.
Customers and partners can self-register on CCO to obtain additional personalized information and services. Registered users may order products, check on the status of an order and view benefits specific to their relationships with Cisco.
You can access CCO in the following ways:
You can e-mail questions about using CCO to cco-team@cisco.com.
The Cisco Technical Assistance Center (TAC) is available to warranty or maintenance contract customers who need technical assistance with a Cisco product that is under warranty or covered by a maintenance contract.
To display the TAC web site that includes links to technical support information and software upgrades and for requesting TAC support, use www.cisco.com/techsupport.
To contact by e-mail, use one of the following:
Language | E-mail Address |
---|---|
English | tac@cisco.com |
Hanzi (Chinese) | chinese-tac@cisco.com |
Kanji (Japanese) | japan-tac@cisco.com |
Hangul (Korean) | korea-tac@cisco.com |
Spanish | tac@cisco.com |
Thai | thai-tac@cisco.com |
In North America, TAC can be reached at 800 553-2447 or 408 526-7209. For other telephone numbers and TAC e-mail addresses worldwide, consult the following web site: http://www.cisco.com/warp/public/687/Directory/DirTAC.shtml.
If you are reading Cisco product documentation on the World Wide Web, you can submit technical comments electronically. Click Feedback in the toolbar and select Documentation. After you complete the form, click Submit to send it to Cisco.
You can e-mail your comments to bug-doc@cisco.com.
To submit your comments by mail, for your convenience many documents contain a response card behind the front cover. Otherwise, you can mail your comments to the following address:
Cisco Systems, Inc.
Document Resource Connection
170 West Tasman Drive
San Jose, CA 95134-9883
We appreciate and value your comments.
This document is to be used in conjunction with the Installing the Line Interface Module on the Cisco 8110 Broadband Network Termination Unit publication.
Access Registrar, AccessPath, Are You Ready, ATM Director, Browse with Me, CCDA, CCDE, CCDP, CCIE, CCNA, CCNP, CCSI, CD-PAC, CiscoLink, the Cisco NetWorks logo, the Cisco Powered Network logo, Cisco Systems Networking Academy, Fast Step, FireRunner, Follow Me Browsing, FormShare, GigaStack, IGX, Intelligence in the Optical Core, Internet Quotient, IP/VC, iQ Breakthrough, iQ Expertise, iQ FastTrack, iQuick Study, iQ Readiness Scorecard, The iQ Logo, Kernel Proxy, MGX, Natural Network Viewer, Network Registrar, the Networkers logo, Packet, PIX, Point and Click Internetworking, Policy Builder, RateMUX, ReyMaster, ReyView, ScriptShare, Secure Script, Shop with Me, SlideCast, SMARTnet, SVX, TrafficDirector, TransPath, VlanDirector, Voice LAN, Wavelength Router, Workgroup Director, and Workgroup Stack are trademarks of Cisco Systems, Inc.; Changing the Way We Work, Live, Play, and Learn, Empowering the Internet Generation, are service marks of Cisco Systems, Inc.; and Aironet, ASIST, BPX, Catalyst, Cisco, the Cisco Certified Internetwork Expert Logo, Cisco IOS, the Cisco IOS logo, Cisco Press, Cisco Systems, Cisco Systems Capital, the Cisco Systems logo, Collision Free, Enterprise/Solver, EtherChannel, EtherSwitch, FastHub, FastLink, FastPAD, IOS, IP/TV, IPX, LightStream, LightSwitch, MICA, NetRanger, Post-Routing, Pre-Routing, Registrar, StrataView Plus, Stratm, SwitchProbe, TeleRouter, are registered trademarks of Cisco Systems, Inc. or its affiliates in the U.S. and certain other countries.
All other brands, names, or trademarks mentioned in this document/website are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any of its resellers. (0008R)
Copyright © 2000 Cisco Systems, Inc.
All rights reserved.
Posted: Tue Mar 13 09:30:06 PST 2001
All contents are Copyright © 1992--2001 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.