Cisco Management Information Bases (MIBs) are archived in Cisco's FTP server and are accessible via anonymous FTP at the following location:
ftp://ftpeng.cisco.com/pub/mibs
The contents of this archive are mirrored in CCO. The Cisco 90 Series MIB is at the following location:
ftp://ftpeng.cisco.com/pub/mibs/v1/CISCO-90-MIB.my
Cisco90Series-MIB DEFINITIONS ::= BEGIN
IMPORTS
enterprises, Counter, TimeTicks
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212
TRAP-TYPE
FROM RFC-1215;
-- From RFC-1213 (MIB-II)
DisplayString ::=
OCTET STRING
ciscoTelesend OBJECT IDENTIFIER ::= { enterprises 1570 }
frMux OBJECT IDENTIFIER ::= { ciscoTelesend 1 }
-- Frame Relay Multiplexer MIB groups
-- system group
frxSys OBJECT IDENTIFIER ::= { frMux 1 }
-- defaults group
frxDefault OBJECT IDENTIFIER ::= { frMux 2 }
-- bank group
frxBank OBJECT IDENTIFIER ::= { frMux 3 }
-- channel unit group
frxChUnit OBJECT IDENTIFIER ::= { frMux 4 }
-- channel unit management group
frxMgt OBJECT IDENTIFIER ::= { frMux 5 }
-- port group
frxPort OBJECT IDENTIFIER ::= { frMux 6 }
-- frxSys group
frxSysDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Description of the Cisco 90 Series System."
::= { frxSys 1 }
frxClockHour OBJECT-TYPE
SYNTAX INTEGER (0..23)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Synchronized 24 hour clock for the Cisco 90 Series system -
Hour. This clock is used by the channel units
and BRITE cards to set the performance monitoring
end-of-hour and end-of-day intervals."
::= { frxSys 2 }
frxClockMin OBJECT-TYPE
SYNTAX INTEGER (0..59)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Synchronized 24 hour clock for the Cisco 90 Series system -
Minutes. This clock is used by the channel units
and BRITE cards to set the performance monitoring
end-of-hour and end-of-day intervals."
::= { frxSys 3 }
frxClockSec OBJECT-TYPE
SYNTAX INTEGER (0..59)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Synchronized 24 hour clock for the Cisco 90 Series system -
Seconds. This clock is used by the channel units
and BRITE cards to set the performance monitoring
end-of-hour and end-of-day intervals."
::= { frxSys 4 }
frxUpTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Time since the agent was last initialized in
0.01 second increments."
::= { frxSys 5 }
frxAdminContact OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Cisco 90 Series administrative contact name."
::= { frxSys 6 }
frxSysName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Administratively assigned name for this Cisco 90 Series agent."
::= { frxSys 7 }
frxSysLoc OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Physical location of the Cisco 90 Series agent."
::= { frxSys 8 }
frxSysVersion OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Cisco 90 Series Agent version number. The version number is
an INTEGER representation of the actual version number string.
The way to translate to a version number string is 200 = 2.0.0,
201 = 2.0.1, etc."
::= { frxSys 9 }
frxUPerfTrapEnable OBJECT-TYPE
SYNTAX INTEGER {
enableUPerfTrap(1),
disableUPerfTrap(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"1=Enable sending the frxUPerfTrap trap to the
SNMP manager when a performance monitoring
threshold is crossed at an Cisco 90 Series channel unit or
a downstream BRITE card.
2=Disable Trap."
::= { frxSys 10 }
frxAgtLinkErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of Annex-D signaling link reliability errors
between the Cisco 90 Series Agent and the Frame Relay Switch.
A signaling reliability error is declared whenever
the Cisco 90 Series Agent did not receive a reply from the
frame relay switch in response to an Annex-D link
integrity poll or full status inquiry poll"
::= { frxSys 11 }
frxAgtProtErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of Annex-D signaling protocol errors
between the Cisco 90 Series Agent and the Frame
Relay Switch. A signaling protocol error is
declared whenever the Cisco 90 Series Agent
receives a reply with incorrect format or
sequence numbers from the frame relay switch in
response to an Annex-D link integrity poll or
full status inquiry poll"
::= { frxSys 12 }
frxAgtChInactive OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of times the Cisco 90 Series Agent Annex-D signaling
channel was declared inactive."
::= { frxSys 13 }
frxAgtChStatus OBJECT-TYPE
SYNTAX INTEGER {
active(1),
inactive(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current status of the Annex-D signaling channel
between the Cisco 90 Series Agent and the Frame Relay Switch."
::= { frxSys 14 }
-- frxDefault group
frxDefaultEnable OBJECT-TYPE
SYNTAX INTEGER {
enableAutoLoad(1),
disableAutoLoad(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"1=Enable automatic loading of defaults (defined
in this group) to the channel unit when the
Download Configuration pushbutton on the channel
unit faceplate is pushed. 2=Disable loading."
::= { frxDefault 1 }
frxDefaultTrap OBJECT-TYPE
SYNTAX INTEGER {
enableConfigureTrap(1),
disableConfigureTrap(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"1=Enable sending the frxDownloadTrap trap to
the SNMP manager when the Download Configuration
pushbutton on the channel unit faceplate is pushed.
2=Disable Trap"
::= { frxDefault 2 }
frxDConfigSrc OBJECT-TYPE
SYNTAX INTEGER {
annexD(1),
snmp(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"System default for frxConfigSrc - used when the
Download Configuration pushbutton on the channel unit
faceplate is pushed and when frxDefaultEnable is set to 1.
1=Data rate and protocol set by Annex-D assignment rules.
2=Data rate and protocol set by the SNMP variables
frxPortSpeed and frxPortProtocol"
::= { frxDefault 3 }
frxDMgtT391 OBJECT-TYPE
SYNTAX INTEGER (5..30)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"System Default for frxMgtT391 - used when the
Download Configuration pushbutton on the channel unit
faceplate is pushed and when frxDefaultEnable is set to 1.
This controls how often (in seconds) the channel units
send an Annex-D poll to the frame relay switch.
This is the Annex-D T391 parameter (Typical value 10)"
::= { frxDefault 4 }
frxDMgtT392 OBJECT-TYPE
SYNTAX INTEGER (5..30)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"System Default for frxMgtT392 - used when the
Download Configuration pushbutton on the channel unit
faceplate is pushed and when frxDefaultEnable is set to 1.
This controls how long (in seconds) the channel unit
will wait for a subscriber to send it an Annex-D poll
before declaring a link error from the subscriber.
This is the Annex-D T392 parameter (Typical value 15)"
::= { frxDefault 5 }
frxDMgtN391 OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"System Default for frxMgtN391 - used when the
Download Configuration pushbutton on the channel unit
faceplate is pushed and when frxDefaultEnable is set to 1.
This controls how often the channel units send a full
status inquiry poll to the frame relay switch instead of
a link integrity verification poll.
This is the Annex-D N391 parameter (Typical value 6)"
::= { frxDefault 6 }
frxDMgtN392 OBJECT-TYPE
SYNTAX INTEGER (1..10)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"System Default for frxMgtN392 - used when the
Download Configuration pushbutton on the channel unit
faceplate is pushed and when frxDefaultEnable is set to 1.
When more than frxMgtN392 errors are detected in any
frxMgtN393 monitored Annex-D events, the network is
declared inactive.
This is the Annex-D N392 parameter (Typical value 3)"
::= { frxDefault 7 }
frxDMgtN393 OBJECT-TYPE
SYNTAX INTEGER (1..10)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"System Default for frxMgtN393 - used when the
Download Configuration pushbutton on the channel unit
faceplate is pushed and when frxDefaultEnable is set to 1.
When more than frxMgtN392 errors are detected in any
frxMgtN393 monitored Annex-D events, the network is
declared inactive.
This is the Annex-D N393 parameter (Typical value 4)"
::= { frxDefault 8 }
frxDPortSpeed OBJECT-TYPE
SYNTAX INTEGER {
use56kbps(1),
use64kbps(2),
use128kbps(3),
use144kbps(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"System Default for frxPortSpeed - used when the
Download Configuration pushbutton on the channel unit
faceplate is pushed and when frxDefaultEnable is set to 1.
This is the speed that the channel unit port runs at.
1=56kbps 2=64kbps 3=128kbps 4=144kbps"
::= { frxDefault 9 }
frxDPortProtocol OBJECT-TYPE
SYNTAX INTEGER {
frameRelay(1),
ppp(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"System Default for frxPortProtocol - used when the
Download Configuration pushbutton on the channel unit
faceplate is pushed and when frxDefaultEnable is set to 1.
1=Port uses Frame Relay protocol
2=Port uses PPP protocol - do RFC-1973 encapsulation"
::= { frxDefault 10 }
frxDCktCIR OBJECT-TYPE
SYNTAX INTEGER (0..1544000)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"System Default for frxCktCIR - used when the
Download Configuration pushbutton on the channel unit
faceplate is pushed and when frxDefaultEnable is set to 1.
This is the committed information rate (CIR) in bits per
second. (Typical value 1536000/#ports)"
::= { frxDefault 11 }
frxDCktBc OBJECT-TYPE
SYNTAX INTEGER (0..16777215)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"System Default for frxCktBc - used when the
Download Configuration pushbutton on the channel unit
faceplate is pushed and when frxDefaultEnable is set to 1.
This is the committed BurstSize (Bc) in bits. The time
interval over which the burst is measured is Bc/CIR.
(Typically set to same number as frxDCktCIR)."
::= { frxDefault 12 }
frxDCktBe OBJECT-TYPE
SYNTAX INTEGER (0..16777212)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"System Default for frxCktBe - used when the
Download Configuration pushbutton on the channel unit
faceplate is pushed and when frxDefaultEnable is set to 1.
This is the excess BurstSize (Be) in bits. The time
interval over which the excess burst is measured is Be/CIR.
(Typical value 1536000)."
::= { frxDefault 13 }
-- frxBank group
-- frxBank Table
frxBankTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrxBankEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This Cisco 90 Series Bank Di-group Table contains channel
bank level information for each of the channel bank di-groups
in the system. A di-group is a T1 interface to the frame
relay network. The table is indexed using the Cisco 90 Series
channel bank digroup number"
::= { frxBank 1 }
frxBankEntry OBJECT-TYPE
SYNTAX FrxBankEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A specific entry in the Cisco 90 Series Bank Di-group
Table. There is one entry for each channel bank di-group
(T1) in the system. There are no entries for unused banks"
INDEX {
frxBankIndex
}
::= { frxBankTable 1 }
FrxBankEntry ::= SEQUENCE {
frxBankIndex INTEGER,
frxBankType INTEGER
}
frxBankIndex OBJECT-TYPE
SYNTAX INTEGER (16..1007)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Channel Bank Di-group Number. This index is used to address
the various channel banks in the system. This number is the
same as the DLCI number used to communicate with the bank at
the Cisco 90 SNMP Agent. (note that this is NOT the same
as the DLCI number at the channel bank. The channel bank
always uses DLCI 30 or 31 to communicate with the Agent.)"
::= { frxBankEntry 1 }
frxBankType OBJECT-TYPE
SYNTAX INTEGER {
d4(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This is the type of channel bank and is for future use.
D4 banks return a value of 1."
::= { frxBankEntry 2 }
-- frxChUnit group
-- frxChUnit Table
frxChUTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrxChUEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This Cisco 90 Series Channel Unit Table contains channel unit
level control and statistics for each of the Cisco 90 Series
channel units in the system. The table is indexed
first using the Cisco 90 Series channel bank digroup number,
then the channel unit number (1 to 24)."
::= { frxChUnit 1 }
frxChUEntry OBJECT-TYPE
SYNTAX FrxChUEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A specific entry in the Cisco 90 Series Channel Unit Table.
There is one entry for each Cisco 90 Series channel unit in
the system. There are no entries for unused banks or empty
channel unit slots"
INDEX {
frxBankIndex,
frxChUIndex
}
::= { frxChUTable 1 }
FrxChUEntry ::= SEQUENCE {
frxChUIndex INTEGER,
frxChUType INTEGER,
frxChUVersion INTEGER,
frxSigProtocol INTEGER,
frxConfigSrc INTEGER,
frxDLCIAdLen INTEGER,
frxNetInOctets Counter,
frxNetOutOctets Counter,
frxNetBadFrames Counter,
frxNetHDLCEs Counter,
frxNetCRCEs Counter,
frxNetLinkEs Counter,
frxNetFrShEs Counter,
frxNetFrLgEs Counter,
frxNetPPPEs Counter,
frxNetBufEs Counter
}
frxChUIndex OBJECT-TYPE
SYNTAX INTEGER (1..24)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Channel Unit Number. This index is used to address a
specific channel unit in a bank. For D4 channel banks
this number is the same as the physical slot number 1-24"
::= { frxChUEntry 1 }
frxChUType OBJECT-TYPE
SYNTAX INTEGER {
cisco90i(100)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Type of Cisco 90 Series channel unit installed."
::= { frxChUEntry 2 }
frxChUVersion OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Cisco 90 Series channel unit version number."
::= { frxChUEntry 3 }
frxSigProtocol OBJECT-TYPE
SYNTAX INTEGER {
annexD(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the type of Local In-channel Signaling used
when the subscriber is running frame relay protocol.
It is provided for future use. Set to 1 for T1.617
Annex-D"
::= { frxChUEntry 4 }
frxConfigSrc OBJECT-TYPE
SYNTAX INTEGER {
annexD(1),
snmp(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Source for configuring speed and protocol for each port.
1=Data rate and protocol set by DLCI assignment rules
as reported by Annex-D. This option allows control
of these basic parameters from the frame relay switch
management station instead of the Cisco 90 Series
management station.
2=Data rate and protocol set by SNMP variables
frxPortSpeed and frxPortProtocol"
::= { frxChUEntry 5 }
frxDLCIAdLen OBJECT-TYPE
SYNTAX INTEGER {
twoOctetDlci(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bytes used for the DLCI address.
For future use. 1=two octets."
::= { frxChUEntry 6 }
frxNetInOctets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of octets received by this channel
unit from Frame Relay Switch (on the T1 interface)
Only frames whose DLCI is addressed to a port on
this channel unit are counted. Bad frames, Annex-D
and SNMP frames are not counted. CRC bytes are not
counted"
::= { frxChUEntry 7 }
frxNetOutOctets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of octets transmitted to the Frame
Relay Switch (on the T1 interface) by this channel
unit. Annex-D and SNMP frames are not counted. CRC
bytes are not counted"
::= { frxChUEntry 8 }
frxNetBadFrames OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of frames received on the network (T1)
interface that are discarded by this channel unit.
Possible reasons for discard are:
Frame contained HDLC abort (7 or more ones in a row)
Frame had a CRC error
Frame had a non-integral number of bytes
Frame was too short (less than 5 bytes)
Frame was too long (more than 8192 bytes)
Frame had bad RFC-1973 (PPP) header - this error only
occurs if destination port is set for PPP protocol.
Frame was discarded due to lack of buffer space.
Only frames whose DLCI is addressed to a port on
this channel unit are counted."
::= { frxChUEntry 9 }
frxNetHDLCEs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Network Errored Seconds caused by HDLC aborts (7 or more
ones in a row). Total number of seconds in which a frame
with an HDLC abort is received by this channel unit on
the network (T1) interface. Only frames whose DLCI is
addressed to a port on this channel unit are counted."
::= { frxChUEntry 10 }
frxNetCRCEs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Network Errored Seconds caused by CRC errors.
Total number of seconds in which a frame with a CRC
error is received by this channel unit on the network
(T1) interface. Only frames whose DLCI is addressed
to a port on this channel unit are counted."
::= { frxChUEntry 11 }
frxNetLinkEs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Network Errored Seconds caused by Non-integral Bytes.
Total number of seconds in which a frame with a non-integral
number of bytes is received by this channel unit on the
network (T1) interface. Only frames whose DLCI is addressed
to a port on this channel unit are counted."
::= { frxChUEntry 12 }
frxNetFrShEs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Network Errored Seconds caused by Short Frames received.
Total number of seconds in which a frame that is too
short (less than 5 bytes) is received by this channel
unit on the network (T1) interface. Only frames whose
DLCI is addressed to a port on this channel unit are
counted."
::= { frxChUEntry 13 }
frxNetFrLgEs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Network Errored Seconds caused by Long Frames received.
Total number of seconds in which a frame that is too
long (more than 8192 bytes) is received by this channel
unit on the network (T1) interface. Only frames whose
DLCI is addressed to a port on this channel unit are
counted."
::= { frxChUEntry 14 }
frxNetPPPEs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Errored seconds caused by bad RFC-1973 (PPP) header.
Total number of seconds in which a frame with an
invalid RFC-1973 (PPP) header is received by this
channel unit on the network (T1) interface. Only frames
whose DLCI is addressed to a port that is set to PPP
protocol and is on this channel unit are counted."
::= { frxChUEntry 15 }
frxNetBufEs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Errored Seconds caused by Buffer Overflow.
Total number of seconds in which a frame received
by this channel unit on the network (T1) interface
was discarded due to insufficient buffer space. Only
frames whose DLCI is addressed to a port on this
channel unit are counted."
::= { frxChUEntry 16 }
-- frxMgt group
-- frxMgt Table
frxMgtTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrxMgtEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table monitors and controls the T1-617 Annex-D
parameters used by the channel units. There is one
table row for every channel unit in every bank. The
table is indexed first using the Cisco 90 Series channel
bank digroup number, then the channel unit number (1 to 24).
For best performance, all of the channel units in a
given bank should be set to identical values. These
values are typically set using global parameters in the
frxDefaultTable instead of directly via this table. "
::= { frxMgt 1 }
frxMgtEntry OBJECT-TYPE
SYNTAX FrxMgtEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A specific entry in the Cisco 90 Series Management Table.
There is one entry for each Cisco 90 Series channel unit
in the system. There are no entries for unused banks or
empty channel unit slots"
INDEX {
frxBankIndex,
frxChUIndex
}
::= { frxMgtTable 1 }
FrxMgtEntry ::= SEQUENCE {
frxPortsInSvc INTEGER,
frxMgtT391 INTEGER,
frxMgtT392 INTEGER,
frxMgtN391 INTEGER,
frxMgtN392 INTEGER,
frxMgtN393 INTEGER,
frxNetLinkErrors Counter,
frxNetProtErrors Counter,
frxNetChInactive Counter,
frxNetChStatus INTEGER
}
frxPortsInSvc OBJECT-TYPE
SYNTAX INTEGER (0..4)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ports in service. The number of ports on a Cisco 90 Series
channel unit that have one or more active PVCs, as determined
by Annex-D."
::= { frxMgtEntry 1 }
frxMgtT391 OBJECT-TYPE
SYNTAX INTEGER (5..30)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This controls how often (in seconds) the channel unit
sends an Annex-D poll to the frame relay switch.
This is the Annex-D T391 parameter (Typical value 10)"
::= { frxMgtEntry 2 }
frxMgtT392 OBJECT-TYPE
SYNTAX INTEGER (5..30)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This controls how long (in seconds) the channel unit
will wait for a subscriber to send it an Annex-D poll
before declaring a link error from the subscriber.
This is the Annex-D T392 parameter (Typical value 15)"
::= { frxMgtEntry 3 }
frxMgtN391 OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This controls how often (in polls) the channel unit
sends a full status inquiry poll to the frame relay
switch instead of a link integrity verification poll.
This is the Annex-D N391 parameter (Typical value 6)"
::= { frxMgtEntry 4 }
frxMgtN392 OBJECT-TYPE
SYNTAX INTEGER (1..10)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When more than frxMgtN392 errors are detected in any
frxMgtN393 monitored Annex-D events, the network is
declared inactive. This is the Annex-D N392 parameter
(Typical value 3)"
::= { frxMgtEntry 5 }
frxMgtN393 OBJECT-TYPE
SYNTAX INTEGER (1..10)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When more than frxMgtN392 errors are detected in any
frxMgtN393 monitored Annex-D events, the network is
declared inactive. This is the Annex-D N393 parameter
(Typical value 4)"
::= { frxMgtEntry 6 }
frxNetLinkErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of signaling link reliability errors from
network. A signaling reliability error is declared
whenever the channel units did not receive a reply
from the frame relay switch to an Annex-D link
integrity poll or full status inquiry poll"
::= { frxMgtEntry 7 }
frxNetProtErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of signaling protocol errors from network.
A signaling protocol error is declared whenever
the channel units receive a reply with incorrect
format or sequence numbers from the frame relay
switch in response to an Annex-D link integrity
poll or full status inquiry poll"
::= { frxMgtEntry 8 }
frxNetChInactive OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of times network Annex-D signaling channel
was declared inactive."
::= { frxMgtEntry 9 }
frxNetChStatus OBJECT-TYPE
SYNTAX INTEGER {
active(1),
inactive(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current status of the Annex-D signaling channel on
the network side of the channel bank."
::= { frxMgtEntry 10 }
-- frxMgtPortTable
frxMgtPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrxMgtPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table monitors the T1-617 Annex-D link
between the channel units and the subscribers.
There is one table row for every port on every
channel unit in every bank. The table is indexed
first using the channel bank digroup number, then
the channel unit number (1 to 24), and then the
port number (0 to 3)."
::= { frxMgt 2 }
frxMgtPortEntry OBJECT-TYPE
SYNTAX FrxMgtPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A specific entry in the Cisco 90 Series Management Port
Table. There is one entry for each port on each
Cisco 90 Series channel unit in the system. There are no
entries for unused banks or empty channel unit
slots."
INDEX {
frxBankIndex,
frxChUIndex,
frxPortIndex
}
::= { frxMgtPortTable 1 }
FrxMgtPortEntry ::= SEQUENCE {
frxPortIndex INTEGER,
frxPortLinkErrors Counter,
frxPortProtErrors Counter,
frxPortChInactive Counter
}
frxPortIndex OBJECT-TYPE
SYNTAX INTEGER (0..3)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Which subscriber port on the channel unit is
addressed. Ports are numbered from 0 to 3.
Some channel unit types have less than 4 ports."
::= { frxMgtPortEntry 1 }
frxPortLinkErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of signaling link reliability errors from
subscriber port. A signaling reliability error is
declared whenever the channel units did not receive
an Annex-D link integrity poll or full status inquiry
poll from the subscriber port within the required time."
::= { frxMgtPortEntry 2 }
frxPortProtErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of signaling protocol errors from subscriber
port. A signaling protocol error is declared whenever
the channel units receive an Annex-D link integrity
poll or full status inquiry poll with incorrect
format or sequence numbers from the subscriber port."
::= { frxMgtPortEntry 3 }
frxPortChInactive OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of times the subscriber port Annex-D signaling
channel was declared inactive"
::= { frxMgtPortEntry 4 }
-- frxPort group
-- frxPort Table
frxPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrxPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This Cisco 90 Series Port Table contains per-port control and
statistics for each of the subscriber ports in the
system. The table is indexed first using the Cisco 90 Series
channel bank digroup number, then by the channel
unit number (1 to 24), and finally by the port
number (0-3)."
::= { frxPort 1 }
frxPortEntry OBJECT-TYPE
SYNTAX FrxPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A specific entry in the Cisco 90 Series Port Table. There is
one entry for each port on each Cisco 90 Series channel unit
in the system. There are no entries for unused banks or
empty channel unit slots."
INDEX {
frxBankIndex,
frxChUIndex,
frxPortIndex
}
::= { frxPortTable 1 }
FrxPortEntry ::= SEQUENCE {
frxPortSpeed INTEGER,
frxPortProtocol INTEGER,
frxDSLStatus INTEGER,
frxPVCAssigned INTEGER,
frxLastChange TimeTicks,
frxBrite INTEGER,
frxDSLInOctets Counter,
frxDSLOutOctets Counter,
frxT1InOctets Counter,
frxT1OutOctets Counter,
frxDSLBadFrames Counter,
frxDSLHDLCEs Counter,
frxDSLCRCEs Counter,
frxDSLLinkEs Counter,
frxDSLFrShEs Counter,
frxDSLFrLgEs Counter,
frxDSLDLCIEs Counter,
frxTxBuf INTEGER,
frxRxBuf INTEGER,
frxPortNetEs Counter
}
frxPortSpeed OBJECT-TYPE
SYNTAX INTEGER {
use56kbps(1),
use64kbps(2),
use128kbps(3),
use144kbps(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This is the speed that the channel unit port runs at.
1=56kbps 2=64kbps 3=128kbps 4=144kbps
This parameter can only be changed if frxConfigSrc is
set to SNMP."
::= { frxPortEntry 1 }
frxPortProtocol OBJECT-TYPE
SYNTAX INTEGER {
frameRelay(1),
ppp(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter controls what protocol the channel
unit should expect the subscriber to send on the port.
1=Port uses Frame Relay protocol - no encapsulation
2=Port uses PPP protocol - do RFC-1973 encapsulation
This parameter can only be changed if frxConfigSrc is
set to SNMP."
::= { frxPortEntry 2 }
frxDSLStatus OBJECT-TYPE
SYNTAX INTEGER {
loopDown(1),
dslSyncOnly(2),
loopUpInactive(3),
loopUp(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the status of the DSL loop to the subscriber.
1=Loop is down.
2=Frx card has achieved physical layer activation with
the first BRITE card or the NT1 if there are no BRITE cards.
3=Link is up but Annex-D is still inactive. The ACT bit has
been exchanged with the NT1 indicating a clear channel path
to the customer has been established. Ports running protocols
(i.e. PPP) that do not support Annex-D will never be in this
state.
4=Link is fully up. Annex-D (if appropriate) is active."
::= { frxPortEntry 3 }
frxPVCAssigned OBJECT-TYPE
SYNTAX INTEGER (0..8)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of PVCs assigned to Subscriber Port as determined
by Annex-D"
::= { frxPortEntry 4 }
frxLastChange OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Time since DSL went in sync or lost sync in 0.01
second increments."
::= { frxPortEntry 5 }
frxBrite OBJECT-TYPE
SYNTAX INTEGER (0..6)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of BRITE cards downstream. BRITE cards are used
to extend the loop over subscriber loop carrier systems
and are detected via a background polling operation."
::= { frxPortEntry 6 }
frxDSLInOctets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of octets received from the subscriber DSL
Does not include Annex-D octets"
::= { frxPortEntry 7 }
frxDSLOutOctets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of octets transmitted to the subscriber DSL.
Does not include Annex-D octets"
::= { frxPortEntry 8 }
frxT1InOctets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of octets received from the network
directed at this subscriber port"
::= { frxPortEntry 9 }
frxT1OutOctets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of octets transmitted to the network
from this subscriber port"
::= { frxPortEntry 10 }
frxDSLBadFrames OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of frames received from this subscriber port
that were discarded. Possible reasons for discard are:
Frame contained HDLC abort (7 or more ones in a row)
Frame had a CRC error
Frame had a non-integral number of bytes
Frame was too short (less than 5 bytes)
Frame was too long (more than 8192 bytes)
Frame had illegal DLCI (not 16-23)
Frame was discarded due to lack of buffer space or
due to congestion control"
::= { frxPortEntry 11 }
frxDSLHDLCEs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Subscriber port Errored Seconds caused by HDLC aborts
(7 or more ones in a row). Total number of seconds in
which a frame with an HDLC abort is received from this
port."
::= { frxPortEntry 12 }
frxDSLCRCEs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Subscriber port Errored Seconds caused by CRC errors.
Total number of seconds in which a frame with a CRC
error is received from this port."
::= { frxPortEntry 13 }
frxDSLLinkEs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Subscriber port Errored Seconds caused by Non-integral
Bytes. Total number of seconds in which a frame with a
non-integral number of bytes is received from this
port."
::= { frxPortEntry 14 }
frxDSLFrShEs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Subscriber port Errored Seconds caused by Short Frames.
received Total number of seconds in which a frame that
is too short (less than 5 bytes) is received from this
port."
::= { frxPortEntry 15 }
frxDSLFrLgEs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Subscriber port Errored Seconds caused by Long Frames
received. Total number of seconds in which a frame that
is too long (more than 8192 bytes) is received from this
port."
::= { frxPortEntry 16 }
frxDSLDLCIEs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Subscriber port Errored Seconds caused by illegal DLCI.
Total number of seconds in which a frame that has a DLCI
other than 16 to 23 (or 0) is received from this port."
::= { frxPortEntry 17 }
frxTxBuf OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of octets in the transmit buffer for this
subscriber port. This data is waiting to be sent
to the network (T1)."
::= { frxPortEntry 18 }
frxRxBuf OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of octets in the receive buffer for this
subscriber port. This data is from the network (T1)
and is waiting to be sent to the subscriber port."
::= { frxPortEntry 19 }
frxPortNetEs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of seconds in which a frame received
from the network (T1) and targeted at this subscriber
port was discarded."
::= { frxPortEntry 20 }
-- frxCircuit Table
frxCircuitTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrxCircuitEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This Cisco 90 Series Circuit Table contains
per-virtual-circuit control and statistics for each of the
permanent virtual circuits in the system. The table is
indexed first using the Cisco 90 Series channel bank
digroup number, then by the channel unit number (1 to 24),
then by the port number (0-3) and finally by the circuit
DLCI number (16 to 23)."
::= { frxPort 2 }
frxCircuitEntry OBJECT-TYPE
SYNTAX FrxCircuitEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A specific entry in the Cisco 90 Series Circuit Table.
There is one entry for each permanent virtual circuit
in the system. There are no entries for unused
banks or empty channel unit slots."
INDEX {
frxBankIndex,
frxChUIndex,
frxPortIndex,
frxPvcIndex
}
::= { frxCircuitTable 1 }
FrxCircuitEntry ::= SEQUENCE {
frxPvcIndex INTEGER,
frxCktCIR INTEGER,
frxCktBc INTEGER,
frxCktBe INTEGER,
frxFarEndOpStat INTEGER,
frxCktInOctets Counter,
frxCktOutOctets Counter,
frxCktInFrames Counter,
frxCktOutFrames Counter,
frxCktDiscards Counter
}
frxPvcIndex OBJECT-TYPE
SYNTAX INTEGER (16..23)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This index is the subscriber loop DLCI number of the
permanent virtual circuit. It ranges from 16 to 23.
The corresponding network side DLCI must be assigned
in the frame relay switch and communicated to the Cisco 90
Series channel units via the Annex-D protocol before this
element can be addressed."
::= { frxCircuitEntry 1 }
frxCktCIR OBJECT-TYPE
SYNTAX INTEGER (0..1544000)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This is the committed information rate (CIR) in bits
per second for the addressed permanent virtual circuit.
(Typical value 1536000/#ports)."
::= { frxCircuitEntry 2 }
frxCktBc OBJECT-TYPE
SYNTAX INTEGER (0..16777215)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This is the Committed Burst Size (Bc) in bits for the
addressed permanent virtual circuit. The time interval
over which the burst is measured is Bc/CIR. (Typically
set to same number as frxCktCIR)."
::= { frxCircuitEntry 3 }
frxCktBe OBJECT-TYPE
SYNTAX INTEGER (0..16777215)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This is the Excess Burst Size (Be) in bits for the
addressed permanent virtual circuit. The time interval
over which the excess burst is measured is Be/CIR.
(Typical value 1536000)."
::= { frxCircuitEntry 4 }
frxFarEndOpStat OBJECT-TYPE
SYNTAX INTEGER {
active(1),
inactive(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the status of the far end of the frame relay
permanent virtual circuit (through the frame relay
network) as determined by Annex-D.
1=active
2=inactive"
::= { frxCircuitEntry 5 }
frxCktInOctets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of input octets from the subscriber port
on the addressed permanent virtual circuit. These
octets are destined for the network (T1)."
::= { frxCircuitEntry 6 }
frxCktOutOctets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of output octets to the subscriber port
on the addressed permanent virtual circuit. These
octets were received from the network (T1)."
::= { frxCircuitEntry 7 }
frxCktInFrames OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of input frames from the subscriber port
on the addressed permanent virtual circuit. These
frames are destined for the network (T1)."
::= { frxCircuitEntry 8 }
frxCktOutFrames OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of output frames to the subscriber port
on the addressed permanent virtual circuit. These
frames were received from the network (T1)."
::= { frxCircuitEntry 9 }
frxCktDiscards OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of input frames from the subscriber port
on the addressed permanent virtual circuit that were
discarded due to congestion (lack of buffer space or
congestion control."
::= { frxCircuitEntry 10 }
-- frxUEoc Table
frxUEocTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrxUEocEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This Cisco 90 Series Embedded Operations Channel Table
is used to diagnose and sectionalize problems with the
subscriber loop. It contains one entry for each of the
Cisco 90 Series channel units in the system. The table
is indexed first using the Cisco 90 Series channel bank
digroup number, then the channel unit number (1 to 24)."
::= { frxPort 3 }
frxUEocEntry OBJECT-TYPE
SYNTAX FrxUEocEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A specific entry in the Cisco 90 Series Embedded Operations
Channel Table. There is one entry for each Cisco 90 Series
channel unit in the system. There are no entries for unused
banks or empty channel unit slots"
INDEX {
frxBankIndex,
frxChUIndex
}
::= { frxUEocTable 1 }
FrxUEocEntry ::= SEQUENCE {
frxTestPort INTEGER,
frxTestType INTEGER,
frxLoopLoc INTEGER,
frxLoopCh INTEGER,
frxStartTest INTEGER,
frxBertRst INTEGER,
frxBertBE Counter,
frxBertTestTime TimeTicks,
frxTestInProg INTEGER
}
frxTestPort OBJECT-TYPE
SYNTAX INTEGER (0..3)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter indicates which subscriber port on the
channel unit to test. It has no effect until frxStartTest
is set to start the test. Only one port on a given channel
unit may be tested at a time."
::= { frxUEocEntry 1 }
frxTestType OBJECT-TYPE
SYNTAX INTEGER {
loopbackAndBert(1),
bertOnly(2),
sendCorruptCRC(3),
loopbackOnly(4),
localLoopAllPorts(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter indicates the type of test to perform. It
has no effect until frxStartTest is set to start the test.
1=Set up a loopback and run a PN-2047 Bit Error Rate Test.
2=Run a (straightaway) PN-2047 Bit Error Rate Test. This
test assumes a loopback has been manually set up somewhere
downstream or another test set running PN-2047 BERT is
connected downstream.
3=Send corrupted CRC on the DSL. This has no effect on the
frame relay CRC, only the out-of-band DSL CRC (used for
performance monitoring) is corrupted.
4=Set up a loopback at the specified location to loop the
frame relay or PPP data in both directions.
5=Setup a local loopback on all 4 ports. frxTestPort and
frxLoopLoc are ignored for this test."
::= { frxUEocEntry 2 }
frxLoopLoc OBJECT-TYPE
SYNTAX INTEGER {
localFrx(7),
briteCard1(1),
briteCard2(2),
briteCard3(3),
briteCard4(4),
briteCard5(5),
briteCard6(6),
nt1(8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter indicates the location of the loopback or
the card that will send corrupt CRC. It has no effect
until frxStartTest is set to start the test. It has no
effect for a BertOnly test.
7=Local Cisco 90 Series card 8=NT1 at customer premise
1 to 6 is used to address intervening BRITE cards."
::= { frxUEocEntry 3 }
frxLoopCh OBJECT-TYPE
SYNTAX INTEGER {
b1only(1),
b2only(2),
all(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter indicates which channels to use for the
loopbackOnly and localLoopAllPorts test. It has no effect
until frxStartTest is set to start the test. Note that the
loopbackAndBert test always loops all channels back.
1=B1 channel 2=B2 channel 3=All channels (includes all
B channels plus all D channels"
::= { frxUEocEntry 4 }
frxStartTest OBJECT-TYPE
SYNTAX INTEGER {
stopTest(1),
startTest(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter is used to start and stop the test.
frxTestPort, frxTestType, frxLoopLoc, and frxLoopCh should
be set up prior to starting the test.
1=stop test. 2=start test."
::= { frxUEocEntry 5 }
frxBertRst OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
resetBert(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter may be used during a LoopbackAndBert test
or a BertOnly test to reset the frxBertBE counter. It
must be returned to the normal posiion to allow errors to
be counted.
1=normal. 2=Reset BERT counter."
::= { frxUEocEntry 6 }
frxBertBE OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BERT test block errors"
::= { frxUEocEntry 7 }
frxBertTestTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BERT test time in 0.01 second increments"
::= { frxUEocEntry 8 }
frxTestInProg OBJECT-TYPE
SYNTAX INTEGER {
testInProgress(1),
normalOperation(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Test in progress (1); Normal operation (2)"
::= { frxUEocEntry 9 }
-- frxUThr Table
frxUThrTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrxUThrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains the U-interface Performance Monitoring
Thresholds and Alarms for each of the subscriber loops in
the system and for any BRITE cards extending those loops
(e.g. using Subscriber Loop Carrier systems) The table is
indexed first using the Cisco 90 Series channel bank digroup
number, then the channel unit number (1 to 24), then the port
number (0, 1, etc) and finally the location number (the BRITE
card number (1 to 6) or 7 for local parameters in the Cisco
90 Series card). These registers are defined by Bellcore
TR-TSY-000829."
::= { frxPort 4 }
frxUThrEntry OBJECT-TYPE
SYNTAX FrxUThrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A specific entry in the U-interface Performance Monitoring
Threshold table. There is one entry for each port on each
Cisco 90 Series channel unit in the system and one entry for
each BRITE card extending those ports. There are no entries
for unused banks or empty channel unit slots"
INDEX {
frxBankIndex,
frxChUIndex,
frxPortIndex,
frxPAddrIndex
}
::= { frxUThrTable 1 }
FrxUThrEntry ::= SEQUENCE {
frxPAddrIndex INTEGER,
frxChEsTh INTEGER,
frxCdEsTh INTEGER,
frxChSesTh INTEGER,
frxCdSesTh INTEGER,
frxAlertMask INTEGER,
frxThCond INTEGER
}
frxPAddrIndex OBJECT-TYPE
SYNTAX INTEGER {
localFrx(7),
briteCard1(1),
briteCard2(2),
briteCard3(3),
briteCard4(4),
briteCard5(5),
briteCard6(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the physical location where the performance
monitoring takes place. It may be set to localFrx(7)
to access and control PM values local to the Cisco 90
Series channel unit. If there are BRITE cards in the
subscriber loop between the Cisco 90 Series channel
unit and the customer, PM values contained in those
cards may be accessed using briteCard1(1) to
briteCard6(6) where briteCard1 is the card closest
to the Cisco 90 Series channel unit."
::= { frxUThrEntry 1 }
frxChEsTh OBJECT-TYPE
SYNTAX INTEGER (1..3600)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Current Hour Errored Seconds threshold. This
threshold is used for both the transmit and receive
directions. When errors are detected that exceed this
threshold and the corresponding bit in the frxAlertMask
register is 0, the corresponding bit in the frxThCond
register is set and a trap is generated (depending on
the state of frxUPerfTrapEnable). Factory defaut is 40.
Indexed by Bank.ChannelUnit.Port.Address"
::= { frxUThrEntry 2 }
frxCdEsTh OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Current Day Errored Seconds threshold. This
threshold is used for both the transmit and receive
directions. When errors are detected that exceed this
threshold and the corresponding bit in the frxAlertMask
register is 0, the corresponding bit in the frxThCond
register is set and a trap is generated (depending on
the state of frxUPerfTrapEnable). Factory defaut is 100.
Indexed by Bank.ChannelUnit.Port.Address"
::= { frxUThrEntry 3 }
frxChSesTh OBJECT-TYPE
SYNTAX INTEGER (1..3600)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Current Hour Severely Errored Seconds threshold. This
threshold is used for both the transmit and receive
directions. When errors are detected that exceed this
threshold and the corresponding bit in the frxAlertMask
register is 0, the corresponding bit in the frxThCond
register is set and a trap is generated (depending on
the state of frxUPerfTrapEnable). Factory defaut is 10.
Indexed by Bank.ChannelUnit.Port.Address"
::= { frxUThrEntry 4 }
frxCdSesTh OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Current Day Severely Errored Seconds threshold. This
threshold is used for both the transmit and receive
directions. When errors are detected that exceed this
threshold and the corresponding bit in the frxAlertMask
register is 0, the corresponding bit in the frxThCond
register is set and a trap is generated (depending on
the state of frxUPerfTrapEnable). Factory defaut is 25.
Indexed by Bank.ChannelUnit.Port.Address"
::= { frxUThrEntry 5 }
frxAlertMask OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8-bit Alert Mask register. One bit for each threshold in
both directions. When set to 1, the corresponding threshold
crossing is ignored. When set to 0, the corresponding threshold
crossing is indicated in frxThCond and may cause a trap to be
sent depending on the state of frxUPerfTrapEnable.
1 Current Day Severely Errored Seconds Receive
2 Current Day Severely Errored Seconds Transmit
4 Current Day Errored Seconds Receive
8 Current Day Errored Seconds Receive
16 Current Hour Severely Errored Seconds Receive
32 Current Hour Severely Errored Seconds Transmit
64 Current Hour Errored Seconds Receive
128 Current Hour Errored Seconds Transmit
Transmit is data from the customer towards the network.
Receive is data from the network towards the Customer.
This register is defined by Bellcore TR-TSY-000829.
Indexed by Bank.ChannelUnit.Port.Address"
::= { frxUThrEntry 6 }
frxThCond OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8-bit Threshold Condition register. One bit for each
threshold in both directions. Set to 1 if the threshold
is exceeded and the corresponding bit in the frxAlertMask
register is set to 0. Only set to 0 by the SNMP manager.
1 Current Day Severely Errored Seconds Receive
2 Current Day Severely Errored Seconds Transmit
4 Current Day Errored Seconds Receive
8 Current Day Errored Seconds Receive
16 Current Hour Severely Errored Seconds Receive
32 Current Hour Severely Errored Seconds Transmit
64 Current Hour Errored Seconds Receive
128 Current Hour Errored Seconds Transmit
Receive is data from the customer towards the network.
Transmit is data from the network towards the Customer.
SNMP manager should reset bits to 0 after they it has been
read by issuing a set using the inverted byte read. Sets
will only reset bits where the set data is a 0. Setting
a bit to a 1 has no effect. This register is defined
by Bellcore TR-TSY-000829. In the spirit of SNMP, the bits
are inverted when read relative to that specification so
the sense of the bits is the same for sets and gets.
Indexed by Bank.ChannelUnit.Port.Address"
::= { frxUThrEntry 7 }
-- frxUPerf Table
frxUPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrxUPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains the U-interface Performance Monitoring
Statistics for each of the subscriber loops in the system
and for any BRITE cards extending those loops (e.g. using
Subscriber Loop Carrier systems) The table is indexed
first using the Cisco 90 Series channel bank digroup number,
then the channel unit number (1 to 24), then the port number
(0, 1, etc) and finally the location number (the BRITE card
number (1 to 6) or 7 for local parameters in the Cisco 90
Series card). These registers are defined by Bellcore
TR-TSY-000829."
::= { frxPort 5 }
frxUPerfEntry OBJECT-TYPE
SYNTAX FrxUPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A specific entry in the U-interface Performance Monitoring
Statistics table. There is one entry for each port on each
Cisco 90 Series channel unit in the system and one entry for
each BRITE card extending those ports. There are no entries for
unused banks or empty channel unit slots"
INDEX {
frxBankIndex,
frxChUIndex,
frxPortIndex,
frxPAddrIndex
}
::= { frxUPerfTable 1 }
FrxUPerfEntry ::= SEQUENCE {
frxResetPM INTEGER,
frxPMtype INTEGER,
frxChEsTx INTEGER,
frxChEsRx INTEGER,
frxPhEsTx INTEGER,
frxPhEsRx INTEGER,
frxH2EsTx INTEGER,
frxH2EsRx INTEGER,
frxH3EsTx INTEGER,
frxH3EsRx INTEGER,
frxH4EsTx INTEGER,
frxH4EsRx INTEGER,
frxH5EsTx INTEGER,
frxH5EsRx INTEGER,
frxH6EsTx INTEGER,
frxH6EsRx INTEGER,
frxH7EsTx INTEGER,
frxH7EsRx INTEGER,
frxH8EsTx INTEGER,
frxH8EsRx INTEGER,
frxCdEsTx INTEGER,
frxCdEsRx INTEGER,
frxPdEsTx INTEGER,
frxPdEsRx INTEGER,
frxChSesTx INTEGER,
frxChSesRx INTEGER,
frxPhSesTx INTEGER,
frxPhSesRx INTEGER,
frxCdSesTx INTEGER,
frxCdSesRx INTEGER,
frxPdSesTx INTEGER,
frxPdSesRx INTEGER,
frxChBeTx INTEGER,
frxChBeRx INTEGER,
frxPhBeTx INTEGER,
frxPhBeRx INTEGER
}
frxResetPM OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
resetPM(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Reset all of the performance monitoring statistics on the
specified Cisco 90 Series channel unit or BRITE card.
1=Normal. 2=Reset. There is no need to set this register
back to Normal after doing a reset."
::= { frxUPerfEntry 1 }
frxPMtype OBJECT-TYPE
SYNTAX INTEGER {
segmentedPM(1),
pathPM(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Determines if the Cisco 90 Series channel unit or the downstream
BRITE cards is doing segmented or path performance monitoring as
specified in Bellcore document TR-NWT-000397. Only segmented
performance monitoring should be used. In segmented PM, CRC
errors are counted on each segment of the loop, instead of
over the entire path. If no BRITE cards exist in the system,
there is no difference between segmented and path PM
1=Segmented. 2=Path."
::= { frxUPerfEntry 2 }
frxChEsTx OBJECT-TYPE
SYNTAX INTEGER (0..3600)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current Hour Errored Seconds - Transmit direction.
Transmit is data from the network towards the customer.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address
(note: DDS loops cannot detect transmit errors)"
::= { frxUPerfEntry 3 }
frxChEsRx OBJECT-TYPE
SYNTAX INTEGER (0..3600)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current Hour Errored Seconds - Receive direction.
Receive is data from the customer towards the network.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address"
::= { frxUPerfEntry 4 }
frxPhEsTx OBJECT-TYPE
SYNTAX INTEGER (0..3600)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Previous Hour Errored Seconds - Transmit direction.
Transmit is data from the network towards the customer.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address
(note: DDS loops cannot detect transmit errors)"
::= { frxUPerfEntry 5 }
frxPhEsRx OBJECT-TYPE
SYNTAX INTEGER (0..3600)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Previous Hour Errored Seconds - Receive direction.
Receive is data from the customer towards the network.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address"
::= { frxUPerfEntry 6 }
frxH2EsTx OBJECT-TYPE
SYNTAX INTEGER (0..3600)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Errored Seconds 2 hours ago - Transmit direction.
Transmit is data from the network towards the customer.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address
(note: DDS loops cannot detect transmit errors)"
::= { frxUPerfEntry 7 }
frxH2EsRx OBJECT-TYPE
SYNTAX INTEGER (0..3600)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Errored Seconds 2 hours ago - Receive direction.
Receive is data from the customer towards the network.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address"
::= { frxUPerfEntry 8 }
frxH3EsTx OBJECT-TYPE
SYNTAX INTEGER (0..3600)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Errored Seconds 3 hours ago - Transmit direction.
Transmit is data from the network towards the customer.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address
(note: DDS loops cannot detect transmit errors)"
::= { frxUPerfEntry 9 }
frxH3EsRx OBJECT-TYPE
SYNTAX INTEGER (0..3600)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Errored Seconds 3 hours ago - Receive direction.
Receive is data from the customer towards the network.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address"
::= { frxUPerfEntry 10 }
frxH4EsTx OBJECT-TYPE
SYNTAX INTEGER (0..3600)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Errored Seconds 4 hours ago - Transmit direction.
Transmit is data from the network towards the customer.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address
(note: DDS loops cannot detect transmit errors)"
::= { frxUPerfEntry 11 }
frxH4EsRx OBJECT-TYPE
SYNTAX INTEGER (0..3600)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Errored Seconds 4 hours ago - Receive direction.
Receive is data from the customer towards the network.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address"
::= { frxUPerfEntry 12 }
frxH5EsTx OBJECT-TYPE
SYNTAX INTEGER (0..3600)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Errored Seconds 5 hours ago - Transmit direction.
Transmit is data from the network towards the customer.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address
(note: DDS loops cannot detect transmit errors)"
::= { frxUPerfEntry 13 }
frxH5EsRx OBJECT-TYPE
SYNTAX INTEGER (0..3600)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Errored Seconds 5 hours ago - Receive direction.
Receive is data from the customer towards the network.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address"
::= { frxUPerfEntry 14 }
frxH6EsTx OBJECT-TYPE
SYNTAX INTEGER (0..3600)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Errored Seconds 6 hours ago - Transmit direction.
Transmit is data from the network towards the customer.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address
(note: DDS loops cannot detect transmit errors)"
::= { frxUPerfEntry 15 }
frxH6EsRx OBJECT-TYPE
SYNTAX INTEGER (0..3600)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Errored Seconds 6 hours ago - Receive direction.
Receive is data from the customer towards the network.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address"
::= { frxUPerfEntry 16 }
frxH7EsTx OBJECT-TYPE
SYNTAX INTEGER (0..3600)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Errored Seconds 7 hours ago - Transmit direction.
Transmit is data from the network towards the customer.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address
(note: DDS loops cannot detect transmit errors)"
::= { frxUPerfEntry 17 }
frxH7EsRx OBJECT-TYPE
SYNTAX INTEGER (0..3600)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Errored Seconds 7 hours ago - Receive direction.
Receive is data from the customer towards the network.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address"
::= { frxUPerfEntry 18 }
frxH8EsTx OBJECT-TYPE
SYNTAX INTEGER (0..3600)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Errored Seconds 8 hours ago - Transmit direction.
Transmit is data from the network towards the customer.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address
(note: DDS loops cannot detect transmit errors)"
::= { frxUPerfEntry 19 }
frxH8EsRx OBJECT-TYPE
SYNTAX INTEGER (0..3600)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Errored Seconds 8 hours ago - Receive direction.
Receive is data from the customer towards the network.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address"
::= { frxUPerfEntry 20 }
frxCdEsTx OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current Day Errored Seconds - Transmit direction.
Transmit is data from the network towards the customer.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address
(note: DDS loops cannot detect transmit errors)"
::= { frxUPerfEntry 21 }
frxCdEsRx OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current Day Errored Seconds - Receive direction.
Receive is data from the customer towards the network.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address"
::= { frxUPerfEntry 22 }
frxPdEsTx OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Previous Day Errored Seconds - Transmit direction.
Transmit is data from the network towards the customer.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address
(note: DDS loops cannot detect transmit errors)"
::= { frxUPerfEntry 23 }
frxPdEsRx OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Previous Day Errored Seconds - Receive direction.
Receive is data from the customer towards the network.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address"
::= { frxUPerfEntry 24 }
frxChSesTx OBJECT-TYPE
SYNTAX INTEGER (0..3600)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current Hour Severely Errored Seconds - Transmit direction.
Transmit is data from the network towards the customer.
Severely Errored Seconds are seconds in which three or more
block errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address
(note: DDS loops cannot detect transmit errors)"
::= { frxUPerfEntry 25 }
frxChSesRx OBJECT-TYPE
SYNTAX INTEGER (0..3600)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current Hour Severely Errored Seconds - Receive direction.
Receive is data from the customer towards the network.
Severely Errored Seconds are seconds in which three or more
block errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address"
::= { frxUPerfEntry 26 }
frxPhSesTx OBJECT-TYPE
SYNTAX INTEGER (0..3600)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Previous Hour Severely Errored Seconds - Transmit direction.
Transmit is data from the network towards the customer.
Severely Errored Seconds are seconds in which three or more
block errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address
(note: DDS loops cannot detect transmit errors)"
::= { frxUPerfEntry 27 }
frxPhSesRx OBJECT-TYPE
SYNTAX INTEGER (0..3600)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Previous Hour Severely Errored Seconds - Receive direction.
Receive is data from the customer towards the network.
Severely Errored Seconds are seconds in which three or more
block errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address"
::= { frxUPerfEntry 28 }
frxCdSesTx OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current Day Severely Errored Seconds - Transmit direction.
Transmit is data from the network towards the customer.
Severely Errored Seconds are seconds in which three or more
block errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address"
::= { frxUPerfEntry 29 }
frxCdSesRx OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current Day Severely Errored Seconds - Receive direction.
Receive is data from the customer towards the network.
Severely Errored Seconds are seconds in which three or more
block errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address"
::= { frxUPerfEntry 30 }
frxPdSesTx OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Previous Day Severely Errored Seconds - Transmit direction.
Transmit is data from the network towards the customer.
Severely Errored Seconds are seconds in which three or more
block errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address"
::= { frxUPerfEntry 31 }
frxPdSesRx OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Previous Day Severely Errored Seconds - Receive direction.
Receive is data from the customer towards the network.
Severely Errored Seconds are seconds in which three or more
block errors occur. These errors are measured at the physical
link level (e.g. DSL CRC or BPV errors) and not at the
frame relay level. This register is defined by Bellcore
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address"
::= { frxUPerfEntry 32 }
frxChBeTx OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current Hour Block Errors - Transmit direction.
Transmit is data from the network towards the customer.
Block errors are 12 millisecond time periods in which a
physical link level (e.g. DSL CRC or BPV) error occurs.
These errors are not the same as frame relay level errors.
This register is defined by Bellcore TR-TSY-000829.
Indexed by Bank.ChannelUnit.Port.Address"
::= { frxUPerfEntry 33 }
frxChBeRx OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current Hour Block Errors - Receive direction.
Receive is data from the customer towards the network.
Block errors are 12 millisecond time periods in which a
physical link level (e.g. DSL CRC or BPV) error occurs.
These errors are not the same as frame relay level errors.
This register is defined by Bellcore TR-TSY-000829.
Indexed by Bank.ChannelUnit.Port.Address"
::= { frxUPerfEntry 34 }
frxPhBeTx OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Previous Hour Block Errors - Transmit direction.
Transmit is data from the network towards the customer.
Block errors are 12 millisecond time periods in which a
physical link level (e.g. DSL CRC or BPV) error occurs.
These errors are not the same as frame relay level errors.
This register is defined by Bellcore TR-TSY-000829.
Indexed by Bank.ChannelUnit.Port.Address"
::= { frxUPerfEntry 35 }
frxPhBeRx OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Previous Hour Block Errors - Receive direction.
Receive is data from the customer towards the network.
Block errors are 12 millisecond time periods in which a
physical link level (e.g. DSL CRC or BPV) error occurs.
These errors are not the same as frame relay level errors.
This register is defined by Bellcore TR-TSY-000829.
Indexed by Bank.ChannelUnit.Port.Address"
::= { frxUPerfEntry 36 }
-- frx Traps
frxDownloadTrap TRAP-TYPE
ENTERPRISE frMux
VARIABLES { frxBankIndex, frxChUIndex }
DESCRIPTION
"This trap is sent if the Download Config pushbutton
on the channel unit faceplate is pushed and frxDefaultTrap
is set to 1."
::= 1
frxUPerfTrap TRAP-TYPE
ENTERPRISE frMux
VARIABLES { frxBankIndex, frxChUIndex }
DESCRIPTION
"This trap is sent if a performance monitoring threshold
on a channel unit or a BRITE card is exceeded and the
corresponding bit in the frxAlertMask is enabled and
frxUPerfTrapEnable is enabled. The manager should read
and clear all of the threshold condition registers
for the specified channel unit to enable the trap to
be sent again."
::= 2
frxInsertChUTrap TRAP-TYPE
ENTERPRISE frMux
VARIABLES { frxBankIndex, frxChUIndex }
DESCRIPTION
"This trap is sent when the channel unit is inserted."
::= 3
frxRemoveChUTrap TRAP-TYPE
ENTERPRISE frMux
VARIABLES { frxBankIndex, frxChUIndex }
DESCRIPTION
"This trap is sent when the channel unit is removed."
::= 4
frxDConfigFailed TRAP-TYPE
ENTERPRISE frMux
VARIABLES { frxBankIndex, frxChUIndex }
DESCRIPTION
"This trap is sent if downloading configuration data
to a channel unit fails."
::= 5
END
|