This document provides information about CiscoRemote Plus that became available after the user guide was printed. This document includes the following sections:
This section provides information about potential problems that can result from switching LANs or using a protocol stack other than the stack provided by CiscoRemote Plus.
CiscoRemote Plus allows you to have simultaneous file and printer sharing with both a local and remote LAN. However, if you perform this dual sharing function, both the local and remote LANs must have the same domain name (if you are using Microsoft Windows Networking), or the same network address (if you are using Novell networking). If you attempt to connect to a different LAN for the remote and local networks, you might lose a connection or data.
The CiscoRemote Plus Ping utility works only over the protocol stack provided with CiscoRemote Plus. As a result, if you specified only "TCP/IP LAN Access" as part of your custom installation while running the CiscoRemote Setup application, and a functioning, non-CiscoRemote Transmission Control Protocol/Internet Protocol (TCP/IP) stack is already present, the Ping utility will not be installed.
This section discusses some known problems that you might experience while using CiscoRemote Plus on Windows 95.
The CiscoRemote Plus User Guide incorrectly states that for Windows 95 the network operating system must be installed prior to installing CiscoRemote Plus.
Windows 95 does not require that the network operating system be installed prior to CiscoRemote Plus. As a result, you can link and bind either the Microsoft Windows 95 Networking client or the Microsoft Windows 95 NetWare client to the CiscoRemote Plus driver at any time using the Windows 95 Network Setup application.
Only a single local instance of a local TCP/IP stack is supported. As a result, if you already have the Microsoft TCP/IP stack (or the stack of another vendor) running with a LAN adapter network interface card (NIC), the Local Access option (in the Component Selection screen) is unavailable.
For remote NetBEUI support (over the Connect dial-out), you must disable the NetBEUI Browse function at your workstation. If this is not done, you will be unable to see any nodes on the remote network.
Take the following steps to turn off the NetBEUI BROWSE function:
Step 1 Run the Microsoft Network Setup application.
Step 2 Select the service File & Print Sharing for Microsoft Networks.
Step 3 Click on Properties.
Step 4 Set BrowseMaster to Disabled.
Remote access to NetWare servers from Windows 95 is only supported using the Microsoft Windows 95 NetWare client. If you are using a Novell 16-bit NetWare client in Windows 3.1 or Windows for Workgroups (either NETX or Virtual Loadable Module), you must upgrade to the Windows 95 NetWare 32-bit client. The Windows 95 upgrade automatically replaces the Novell 16-bit NetWare client with a Windows 95 Netware 32-bit client.
CiscoRemote Plus will eventually support the Novell NetWare 32-bit NetWare client, when it becomes fully operational for remote connections.
If you are using a remote Internetwork Packet Exchange (IPX) connection with CiscoRemote Plus, you must set the IPX frame type to either 802.3 or Ethernet_II, as follows for the upgrade to be successful:
Step 1 From the CiscoRemote Plus Control Panel, select Network Properties.
Step 2 Select IPX/SPX-compatible protocol, then select CiscoRemote.
Step 3 Click on the Advanced Tab.
Step 4 Change the Frametype from AUTO to Ethernet 802.3 or Ethernet_II, depending on your needs.
This section provides information on some known problems that you might experience while using CiscoRemote Plus on Windows platforms.
If you want to use Microsoft Networking (either LAN Manager or Windows for Workgroups networking) over the remote dial-up Point-to-Point Protocol (PPP), you must have Microsoft Windows Networking installed before you run the CiscoRemote Plus Setup application. If you already have local LAN support installed, you only need to run the CiscoRemote Plus Setup application.
If Microsoft Windows Networking is not already installed, you can use the Windows for Workgroups Network Setup program to install Microsoft Windows Networking. An INF file for the CiscoRemote Plus PPP/Serial Line Interface Protocol (SLIP) driver is provided on the CiscoRemote Plus CD-ROM under the wfw directory within the imports directory and should be used to bind the Microsoft NetBIOS with the PPP/SLIP driver.
The Microsoft Network Setup application might request files from the original Microsoft Windows for Workgroups disks or CD, so have these present during the installation. After Microsoft Windows Networking is installed, reboot as directed and then run the CiscoRemote Plus Setup application to complete the installation.
To use Microsoft Windows Networking over Remote Dial-Up PPP for Windows 3.x, use the LAN Manager installation and the lanman directory found within the imports directory on the CiscoRemote Plus CD; then follow the earlier directions for Windows for Workgroup.
If you want to use NetWare over the remote dial-up link, you must have the NetWare client software installed before running the CiscoRemote Plus Setup application. If you already have local NetWare LAN support installed, you only need to run the CiscoRemote Setup application.
The DOS and Windows version NetWare client software is provided on the CiscoRemote Plus CD in the doswin directory found within the nwclient directory. Take the following steps to install the NetWare client software:
Step 1 Change your directory to Doswin by selecting it from the Nwclient directory on the CiscoRemote CD.
Step 2 Run the NetWare install.exe program to install the NetWare client.
Step 3 When the NetWare installation requests a Media Access Control (MAC) or NIC driver, direct it to the files in the netware directory found within the imports directory on the CiscoRemote Plus CD to bind with the PPP/SLIP driver.
After the NetWare client software is installed, the setup of the CiscoRemote software proceeds as usual.
Initial tests with the new Novell NetWare 32-bit beta client for DOS and Windows indicate compatibility with the CiscoRemote Plus PPP driver. However, note that this Novell client is in development and therefore still unsupported with CiscoRemote Plus.
If you use Novell NetWare over a remote connection you must unmap any NetWare drives or printers and log out before you disconnect from the remote location. Otherwise, you might be faced with a black screen when you try to exit Windows or a system lock-up within Windows itself. If this occurs, reboot your computer by pressing the reset button or powering the computer off and then on.
With the 16-bit Novell NetWare clients, logging into the NetWare server from Windows or Windows for Workgroups will not run either the system or user login scripts. Mapping drives can only be done manually every time that the user connects and logs into a NetWare server.
If you want login scripting, you can use the included CiscoRemote dialit.exe program to dial up and connect to your remote site before you start Windows. However, this application does not work with Windows 95.
Take the following steps to use the dialit.exe program:
Step 1 In your startnet.bat file (normally found in the Nwclient directory on your hard disk), add the following lines immediately before the C:\nwclient\vlm.exe command:
cd c:\cisco\app
dialit "Cisco default dialup"
Step 2 Replace c:\cisco in the first line with the name of the directory where your CiscoRemote Plus software was stored.
Step 3 Replace "Cisco default dialup" in the second line (include the double quotes) with the name of one of the destinations shown in the Net Launcher destinations list.
Note that the dialit.exe application has the following limitations:
1 ) If you get a message to the effect that "the modem failed to initialize," you might need to comment out (place a semicolon in front of the line) the INIT2 string in the modem initialization file (found in modem.ini within the c:\cisco\app directory) for your modem.
2 ) The dialit program does not update the DNS address from the remote router during initialization. You will need to set this from the Net Launcher for the destination that will be used by the dialit application.
3 ) Once dialit makes a connection and you enter Windows, the Net Launcher does not acknowledge that your computer is already connected to a remote site. Setting the Net Launcher destination to "Remote" will allow you to launch applications with the Net Launcher buttons without dialing out.
Two additional dialit.exe commands are noteworthy. The first disconnects from the remote site and hangs up the modem. The second displays status information about your connection. Both of these commands should be run from the c:\cisco\app directory.
c:\cisco\app\dialit /d
c:\cisco\app\dialit /s
Both of these commands can be run from a DOS window within Windows.
The CiscoRemote Plus CD contains a batch file that enables you to make a set of installation disks in case you need to install from this medium. The DOS batch file, mkdsk.bat, is found in the root directory of the CiscoRemote Plus CD.
When you run mkdsk.bat, the batch file will copy each of the CiscoRemote Plus installation directories onto disks. This process requires 16 blank, formatted, 3.5-inch high density disks.
However, the mkdsk.bat file does not move the NetWare client, the Imports directory, or the manuals to the disks.
A full set of documents is included on the CiscoRemote Plus CD. These files are in HTML format and are meant to be read using Netscape Navigator 2.0 or later. (Other web browsers might not provide the proper formatting of the documents.)
After your installation is complete, double-click on the contents.htm file in the root directory of the CiscoRemote Plus CD to view the table of contents for the various manuals.
The BeyondMail application has replaced Eudora Light as the electronic mail offering for CiscoRemote Plus.
If you are an existing CiscoRemote customer and want to continue using Eudora Light, you must move the entire Eudora subdirectory out of the c:\cisco directory before installing CiscoRemote Plus. Otherwise, the Eudora Light application will be deleted during the installation of CiscoRemote Plus.
Take the following steps to move the Eudora subdirectory:
Step 1 Drag and drop the Eudora subdirectory from the File Manager (in Windows or Windows for Workgroups), to the root directory of the drive.
Step 2 Install CiscoRemote Plus.
Step 3 Move the Eudora subdirectory back into the c:\cisco directory.
The BeyondMail application does not provide an import facility to move existing Eudora Light folders into BeyondMail, so you should save the Eudora subdirectory until you no longer need the mail received using Eudora Light. You cannot move existing Eudora Light folders and mail to BeyondMail.
Cisco Connection Online (CCO), formerly Cisco Information Online (CIO), is Cisco Systems' primary, real-time support channel. Maintenance customers and partners can self-register on CCO to obtain additional content and services.
Available 24 hours a day, 7 days a week, CCO provides a wealth of standard and value-added services to Cisco's customers and business partners. CCO services include product information, software updates, release notes, technical tips, the Bug Navigator, configuration notes, brochures, descriptions of service offerings, and download access to public and authorized files.
CCO serves a wide variety of users through two interfaces that are updated and enhanced simultaneously--a character-based version and a multimedia version that resides on the World Wide Web (WWW). The character-based CCO supports Zmodem, Kermit, Xmodem, FTP, Internet e-mail, and fax download options, and is excellent for quick access to information over lower bandwidths. The WWW version of CCO provides richly formatted documents with photographs, figures, graphics, and video, as well as hyperlinks to related information.
You can access CCO in the following ways:
.
.
For a copy of CCO's Frequently Asked Questions (FAQ), contact cco-help@cisco.com.
For additional information, contact cco-team@cisco.com.
.
To obtain general information about Cisco Systems, Cisco products, or upgrades, contact 800 553-6387, 408 526-7208, or cs-rep@cisco.com.
|