A single Cisco AS5800 consists of a Cisco 5814 dial shelf and a Cisco 7206 router shelf. Table A-1 describes the Cisco 5814 dial shelf specifications, and Table A-2 shows the router shelf network processor card factory-installed DRAM configuration.
For Cisco 7206 router shelf physical specification information, refer to the Cisco 7206 Installation and Configuration Guide that shipped with your router shelf.
Description | Specification |
---|---|
Dimensions (H x W x D) | 28.0 x 17.4 x 23.6 in. (71.1 x 44.2 x 59.9 cm) |
Component Weights |
|
| 278 lb (126.1 kg) |
| 114 lb (51.7 kg) |
| 62 lb (28.1 kg) |
| 2.5 lb (1.1 kg) |
| 8 lb each (3.6 kg) |
| 8 lb each (3.6 kg) |
Component Weight (continued) |
|
| 8.5 lb each (3.8 kg) |
| 27.5 lb (12.5 kg) |
| 8 lb each (3.6 kg) |
| 5.5 lb (2.5 kg) |
| 18.5 lb (8.4 kg) |
| 14 lb each (6.4 kg) |
3.5 lb (1.6 kg) | |
Environmental Requirements |
|
|
23 to 104° F (-5° C to 40° C) |
14 slots | |
44A at -48 VDC | |
Frequency | 50/60 Hz |
2,000W (6820 Btu/hr) | |
AC-input voltages and frequency | 200 to 240 VAC |
AC voltage and current | 200 VAC at 16A maximum1 wide input with power factor correction (PFC) |
AC cable | 12 American Wire Gauge (AWG), with three leads, an IEC-320 receptacle on the power supply end, and a country-dependent plug on the power source end |
DC-input voltage and current | -48 VDC to -60 VDC |
DC-input cable | 6 AWG for North American environments |
DC voltages supplied and maximum, steady-state current (AC- and DC-input) | -48V, 54A maximum |
Relative humidity |
|
|
10 to 90%, noncondensing |
Factory-Installed Memory |
|
32-MB DRAM | |
32-MB DRAM | |
16-MB DRAM | |
Regulatory Compliance |
|
Safety: UL 1950, CSA 22.2 No. 950, EN60950, AUSTEL TS001, Emissions: CFR 47 Part 15 Class A (FCC), CISPR22 Class B, EN55022 Class B, AS/NRZ 3548 Class B, ICES003, VCCI Class B Immunity: IEC 1000-3-2, IEC 1000-3-3, IEC-1000-4-2, IEC-1000-4-3, IEC-1000-4-4, IEC-1000-4-5, IEC-1000-4-6, IEC-1000-4-11, EN50082-1, EN50082-2 For additional compliance information refer to the Regulatory Safety and Compliance Information documents that shipped with your system. |
1Each AC-input power supply requires a minimum of 15A service, with a 15A receptacle at the power source. The power cable supplied with the Cisco AS5800 AC-input power shelf uses a 16A male plug. |
Total DRAM | DRAM Bank 0 | Quantity | DRAM Bank 1 | Quantity | Product Number |
---|---|---|---|---|---|
128 MB | U18 and U25 or | 2 32-MB SIMMs | U4 and U12 or | 2 32-MB SIMMs | MEM-NPE-128MB |
Table A-3 lists the backplane DC power specifications.
Description | Specification |
---|---|
Input voltage | |
| -20 (10 ms) |
Output voltage | |
| -38 VDC |
Current | 42 A |
| 3 A |
Circuit breaker | 50 A |
Table A-4 lists the backplane environmental specifications.
Description | Specification |
---|---|
Dimensions (H x W) | 12.75 x 16.75 in. (32.4 x 42.5 cm) |
Cooling | Maximum inlet air temperature is 131° F (55° C) |
Temperature | |
| 23 to 131° F (-5 to 55° C) |
Humidity | |
| 10 to 90%, noncondensing |
Altitude | |
| 9,843 ft (3,000 m) at 104° F (40° C) |
Thermal shock | |
| 23 to 113° F (-5 to 45° C at 0.5° C) per minute |
Vibration | |
| 1.12 g from 3 to 500 Hz |
Ripple and noise | 200 mV |
Battery feed noise | 3 KHz band between 10 KHz and 20 MHz |
| 70 dBrnC |
Long-term voltage drift | ± -0.5% |
Table A-5 lists blower assembly DC power requirements.
Power | Specification |
---|---|
Voltage to backplane | |
| -38 VDC |
Current | |
| 3.0 A |
Table A-6 lists the blower assembly environmental specifications, which are designed to meet NEC, NEBS, and ETSI requirements.
Specification | Description |
---|---|
Cooling | Maximum inlet air temperature is 131° F (55° C) |
Audible noise | Maximum acoustic noise level is 60 dBa |
Temperature | |
| 23 to 131° F (-5 to 55° C) |
Humidity | |
| 10 to 90%, noncondensing |
Altitude | |
| 9,843 ft (3,000 m) at 104° F (40° C) |
Thermal shock | |
| 23 to 113° F at 32.9° F (-5 to 45° C at 0.5° C) per minute |
Vibration | |
| 1.12 g from 3 to 500 Hz |
Regulatory compliance | ENG-5769 |
Table A-7 lists dial shelf controller card environmental specifications.
Description | Specification |
---|---|
Cooling | Maximum inlet air temperature is 131° F (55° C) |
Temperature |
|
| 23 to 131° F (-5 to 55° C) |
Humidity |
|
| 10 to 90%, noncondensing |
Altitude |
|
| 9,843 ft (3,000 m) at 104° F (40° C) |
Thermal shock |
|
| 23 to 113° F (-5 to 45° C at 0.5° C) per minute |
Vibration |
|
| 1.12 Grms from 3 to 500 Hz |
Ripple and noise | 200 mV |
Battery feed noise | 3kHz band between 10KHz and 20 MHz |
| 70 dBrnC |
Long-term voltage drift | ± -0.5% |
The PEMs provide -48 VDC power, which is distributed through the filter module to the dial shelf backplane. The analog isolators in the filter module are provided with 15 VDC. The PEMs suffer no damage if any or all outputs have no load (no load occurs when there are no cards plugged into the backplane) or if the maximum input voltage is exceeded; however, input voltages that exceed 75 V eventually trip the PEM 60 A circuit breaker, and you might have to reset the breaker as needed.
Table A-8 lists DC output voltage and current specifications.
Power | Description |
---|---|
Voltage to backplane | |
| -38 VDC |
Current | |
| 3 A |
Circuit breaker | 50A |
Table A-9 lists the DC-input power supply environmental specifications, which are designed to meet NEC, NEBS, and ETSI requirements.
Specification | Description |
---|---|
Cooling | Maximum inlet air temperature is 131° F (55° C) |
Temperature | |
| 23 to 131° F (-5 to 55° C) |
Humidity | |
| 10 to 90%, noncondensing |
Altitude | |
| 9,843 ft (3,000 m) at 104° F (40° C) |
Thermal shock | |
| 23° F to 113° F (-5° C to 45° C) at 0.5° C per minute |
Vibration | |
| 1.12 g from 3 to 500 Hz |
Regulatory compliance | ENG-5769 |
Table A-10 lists the filter module DC power requirements.
Description | Specification |
---|---|
Input voltage | |
| -20 (10 mS) |
Output voltage | |
| -38 VDC |
Current | |
| 3 A |
Circuit breaker | 50 A |
Table A-11 lists the filter module environmental specifications.
Specification | Description |
---|---|
Cooling | Maximum inlet air temperature is 131° F (55° C) |
Temperature | |
| 23° F to 131° F (-5° C to 55° C) |
Humidity | |
| 10% to 90%, noncondensing |
Altitude | |
| 9,843 ft (3,000 m) at 104° F (40° C) |
Thermal shock | |
| 23° F to 113° F (-5° C to 45° C at 0.5° C) per minute |
Vibration | |
| 1.12 g from 3 to 500 Hz |
Ripple and noise | 200 mV |
Battery feed noise | 3 kHz band between 10 kHz and 20 MHz |
| 70 dBrnC |
Long-term voltage drift | ± -0.5% |
Regulatory compliance | ENG-5769 |
The AC-input power supply operates between 200 and 240 VAC input voltage and supplies -48 VDC to the dial shelf. The AC-input power supply uses a power factor corrector (PFC) that automatically adjusts for the input voltage being supplied.
Table A-12 lists the AC-input power supply specifications.
Description | Specification |
---|---|
Input | |
| 2666.66 volt amps VA |
| 200 to 240 VAC |
| 50 to 60 Hz |
| 0.90 at 50% of full load; 0.99 at full load |
Output |
|
| 2000W with a maximum configuration and one or two AC-input power supplies |
| -48.0 VDC typical. Frame ground strappable to either output terminal. |
| 0 to 41.6A DC; 2000W maximum |
| 58.1A DC maximum |
| 88% at full load, 240 VAC, with ORing diode |
| 25 in. lb |
Environmental Characteristics |
|
| 5.25 x 17 x 14.4 in. (13.32 x 43.2 x 35.88 cm) |
| Per power supply: 14.5 lb (6.6 kg) Empty power shelf: 18 lb (8.16 kg) |
| 1037 Btu/hr |
| 12 AWG; 16A1 |
| 6 AWG, 2 pairs (black and red) |
| 25.8 to 185 ° F (-40 to 85 ° C) |
| 32 to 122 ° F (0 to 50 ° C) airflow front to back with 3 clearance for exhaust air in unpressurized enclosure |
| 60 dBA typical; sound pressure level measured at 1 m |
| 5% to 95% |
| -200 to 13,000 ft (-61 to 3,962 m); adjust temperature at -7 ° C per 1000 ft. above 8000 ft |
| Lucent L-533809 |
| IEC1000-4-2 |
| 7500 FITS per TR-EOP-000332 1.5 x 105 hours MTBF per RIN |
Regulatory compliance |
|
| CE For compliance information refer to the Cisco AS5800 Universal Access Server Regulatory Compliance and Safety Information document that shipped with your system. |
1Each AC-input power supply requires a minimum of 15A service, with a 15A receptacle at the power source. The power cable supplied with the Cisco AS5800 AC-input power shelf uses a 16A male plug. |
The power supply for the enhanced AC-input power shelf operates between 200 and 240 VAC input voltage and supplies -48 VDC to the dial shelf. The power supply for the enhanced AC-input power shelf uses a power factor corrector (PFC) that automatically adjusts for the input voltage being supplied.
Table A-13 lists the specifications for the enhanced AC-input power shelf AC-input power supply.
Description | Specification |
---|---|
Input | |
| 2666.66 volt amps (VA) |
| 200 to 240 VAC1 |
| 50 to 60 hertz (Hz) |
| 0.90 at 50% of full load; 0.99 at full load |
Output |
|
| 2000W with a maximum configuration and one or two AC-input power supplies |
| -48.0 VDC2 typical |
| 0 to 41.6 amps DC; 2000W maximum |
| 58.1 amps DC maximum |
| 88% at full load, 240 VAC with ORing diode |
| 25 in. lb |
Environmental Characteristics |
|
| 5.25 x 17.32 x 13.6 in. (13.32 x 44 x 34.5 cm) |
| Per power supply: 11 lb (5 kg) Empty power shelf: 14 lb (6.4 kg) |
| 7755 Btu/hr |
| 12 American Wire Gauge (AWG), 16-amp3 |
| 6 AWG, 2 pairs (black and red) |
| 25.8 to 185 ° F (-40 to 85 ° C) |
| 32 to 122 ° F (0 to 50 ° C) airflow front to back with clearance for exhaust air in unpressurized enclosure |
| 60 dBA typical; sound pressure level measured at 1 m |
| 5 to 95% |
| -200 to 13,000 ft (-61 to 3,962 meters); derate at -7 ° C/1000 ft above 8000 ft |
| Cisco Systems ENG-3396 |
| IEC1000-4-2 |
| 150k hours MTBF |
Regulatory compliance |
|
| CE For compliance information see the Cisco AS5800 Universal Access Server Regulatory Compliance and Safety Information document that shipped with your system. |
This section describes and provides pinout information for the cables available for the Cisco AS5800 that connect to the dial shelf, the router shelf, and power modules and supplies. For pinouts and specifications of cables that connect to dial shelf ingress cards (T1/E1, T3) refer to the Cisco AS5800 Universal Access Server Dial Shelf Card Guide.
The dial shelf interconnect port adapter contains a single RJ-45 receptacle, which is used to connect the router shelf to the dial shelf. The cable used for this connection is a Cisco proprietary cable, customized with jackscrews to secure the connection. You must use this specially designed cable, which shipped with your dial shelf interconnect port adapter, to connect the dial shelf to the router shelf.
![]() | Caution
Disconnecting this cable while the system is operating will result in a loss of all calls. |
Figure A-1 shows the dial shelf interconnect cable with jackscrew connectors.
The AC-input power shelf is equipped with four types of cables:
The AC-input connection uses a 15A/240 VAC power cord in Europe, Asia, and North America. The 15A connectors on the AC-input power shelf are incompatible with 15A power strips used in most equipment racks and with the power source used for the router shelf.
![]() | Caution
Do not plug the AC-input power shelf into the same power source as the AC router shelf. |
Figure A-2 shows 15-A North American power connectors.
The European or Asian power cable is rated at 16A/250-VAC. The source-side power cable connector is either shipped to match local compliance, or wired at the installation site.
The DC interconnect cables (see Figure A-3) supplied with your AC-input power shelf attach to bus terminal studs in the AC-input power shelf using ring-lug connectors; the cables then connect to the DC terminal blocks in each PEM.
The monitor cable has a DB-25 connector on the AC-input power shelf end and a DB-9 connector on the dial shelf end that connects to the dial shelf filter module. Figure A-4 shows the monitor cable connectors and receptacles. The pinout of the monitor cable varies slightly between the standard and enhanced AC power shelves.
Table A-14 describes the cable pinout used with the AC power shelf.
DB-9 Pin | Signal Description | DB-25 Pin1 |
---|---|---|
1 | AC power failure warning signal | 11 |
2 | AC power shelf overtemperature signal | 10 |
3 | AC power shelf fault signal | 9 |
4 | Ground | 8 |
6 | Ground | 13 |
7 | Ground | 19 |
8 | Ground | 19 |
9 | AC power shelf missing module | 12 |
1DB-25 pins not listed are not used. |