Cisco AS5800 Specifications

Cisco AS5800 Specifications

System Specifications

A single Cisco AS5800 consists of a Cisco 5814 dial shelf and a Cisco 7206 router shelf. Table A-1 describes the Cisco 5814 dial shelf specifications, and Table A-2 shows the router shelf network processor card factory-installed DRAM configuration.

For Cisco 7206 router shelf physical specification information, refer to the Cisco 7206 Installation and Configuration Guide that shipped with your router shelf.


Table A-1:
Cisco 5814 Dial Shelf Specifications
Description Specification

Dimensions (H x W x D)

28.0 x 17.4 x 23.6 in. (71.1 x 44.2 x 59.9 cm)

Component Weights

  Cisco 5814 dial shelf (with filter module, blower assembly, and 14 cards)

278 lb (126.1 kg)

  Cisco 5814 dial shelf (with filter module, blower assembly, and no cards installed)

114 lb (51.7 kg)

  Cisco 5814 dial shelf chassis (empty)

62 lb (28.1 kg)

  Dial shelf backplane

2.5 lb (1.1 kg)

  Dial shelf trunk card

8 lb each (3.6 kg)

  Dial shelf modem card

8 lb each (3.6 kg)

Component Weight (continued)

  Dial shelf controller card

8.5 lb each (3.8 kg)

  Dial shelf blower assembly

27.5 lb (12.5 kg)

  Dial shelf DC power-entry module

8 lb each (3.6 kg)

  Dial shelf filter module

5.5 lb (2.5 kg)

  AC-input power shelf (empty)

18.5 lb (8.4 kg)

  AC-input power supply

14 lb each (6.4 kg)

  AC-input power shelf safety cover

3.5 lb (1.6 kg)

Environmental Requirements

  Operational temperature
Maximum operating temperature
Acceptable temperature rise
Maximum heat generated

23 to 104° F (-5° C to 40° C)
23 to 120° F (-5° C to 50° C) (not more than 72 hours)
30° C per hour
8,000 BTU

Backplane

14 slots

Power

44A at -48 VDC

Frequency

50/60 Hz

Heat dissipation

2,000W (6820 Btu/hr)

AC-input voltages and frequency

200 to 240 VAC
50 to 60 Hz

AC voltage and current

200 VAC at 16A maximum1 wide input with power factor correction (PFC)
240 VAC at 7A maximum

AC cable

12 American Wire Gauge (AWG), with three leads, an IEC-320 receptacle on the power supply end, and  a country-dependent plug on the power source end

DC-input voltage and current

-48 VDC to -60 VDC

DC-input cable

6 AWG for North American environments
10 mm2 wire for international environments when connecting directly to a DC power source

DC voltages supplied and maximum, steady-state current (AC- and DC-input)

-48V, 54A maximum

Relative humidity

  Operating
Nonoperating

10 to 90%, noncondensing
10 to 95%, noncondensing

Factory-Installed Memory

  Dial shelf controller card

32-MB DRAM

  T1 or E1 trunk card (dial shelf)

32-MB DRAM

  Modem card (dial shelf)

16-MB DRAM

Regulatory Compliance

  Agency approvals

Safety: UL 1950, CSA 22.2 No. 950, EN60950, AUSTEL TS001,
AS/NZS 3260, IEC 950

Emissions: CFR 47 Part 15 Class A (FCC), CISPR22 Class B, EN55022 Class B, AS/NRZ 3548 Class B, ICES003, VCCI Class B

Immunity: IEC 1000-3-2, IEC 1000-3-3, IEC-1000-4-2, IEC-1000-4-3, IEC-1000-4-4, IEC-1000-4-5, IEC-1000-4-6, IEC-1000-4-11, EN50082-1, EN50082-2

For additional compliance information refer to the Regulatory Safety and Compliance Information documents that shipped with your system.

1Each AC-input power supply requires a minimum of 15A service, with a 15A receptacle at the power source. The power cable supplied with the Cisco AS5800 AC-input power shelf uses a 16A male plug.


Table A-2: Router Shelf Network Processor Card DRAM SIMM Configurations
Total DRAM DRAM Bank 0 Quantity DRAM Bank 1 Quantity Product Number

128 MB

U18 and U25 or
U11 and U25

2 32-MB SIMMs

U4 and U12 or
U42 and U52

2 32-MB SIMMs

MEM-NPE-128MB

Backplane Specifications

Table A-3 lists the backplane DC power specifications.


Table A-3: Backplane—DC Power Requirements
Description Specification

Input voltage

Minimum
Minimum/Nominal
Nominal
Maximum/Nominal
Maximum

-20 (10 ms)
-38 VDC
-48 VDC
-72 VDC
-75 (IS)

Output voltage

Maximum
Nominal
Minimum

-38 VDC
-48 VDC
-75 VDC

Current

42 A

Minimum (SS)
Maximum (SS)
Peak (2 sec)

3 A
60 A
80 A

Circuit breaker

50 A

Table A-4 lists the backplane environmental specifications.


Table A-4:
Description Specification

Dimensions (H x W)

12.75 x 16.75 in. (32.4 x 42.5 cm)

Cooling

Maximum inlet air temperature is 131° F (55° C)

Temperature

Operating
Nonoperating

23 to 131° F (-5 to 55° C)
-13 to 158° F (-25 to +70° C)

Humidity

Operating
Nonoperating

10 to 90%, noncondensing
10 to 95%, noncondensing

Altitude

Operating
Nonoperating

9,843 ft (3,000 m) at 104° F (40° C)
15,000 ft (4,570 m) over allowable temperature range

Thermal shock

Operating
Nonoperating

23 to 113° F (-5 to 45° C at 0.5° C) per minute
-13 to 158° F (-25 to 70° C) with changeover time between 2 and 3 min

Vibration

Operating
Nonoperating

1.12 g from 3 to 500 Hz
2 g from 3 to 500 Hz

Ripple and noise

200 mV

Battery feed noise

3 KHz band between 10 KHz and 20 MHz

Voice frequency noise
Radio frequency noise

70 dBrnC
500 mV RMS

Long-term voltage drift

± -0.5%

Backplane—
Environmental Specifications

Blower Assembly Specifications

Table A-5 lists blower assembly DC power requirements.


Table A-5: Blower Assembly—DC Power Requirements
Power Specification

Voltage to backplane

Maximum
Nominal
Minimum

-38 VDC
-48 VDC
-75 VDC

Current

Minimum (SS)
Nominal (SS)
Maximum (SS)
Peak (2 sec)

3.0 A
42.0 A
54.0 A
60.0 A

Table A-6 lists the blower assembly environmental specifications, which are designed to meet NEC, NEBS, and ETSI requirements.


Table A-6: Blower Assembly—Environmental Specifications
Specification Description

Cooling

Maximum inlet air temperature is 131° F (55° C)

Audible noise

Maximum acoustic noise level is 60 dBa

Temperature

Operating
Nonoperating

23 to 131° F (-5 to 55° C)
-13 to 158° F (-25 to 70° C)

Humidity

Operating
Nonoperating

10 to 90%, noncondensing
10 to 95%, noncondensing

Altitude

Operating
Nonoperating

9,843 ft (3,000 m) at 104° F (40° C)
15,000 ft (4,570 m) over allowable temperature range

Thermal shock

Operating
Nonoperating

23 to 113° F at 32.9° F (-5 to 45° C at 0.5°  C) per minute
-13 to 158° F (-25 to 70° C) with changeover time between 2 and 3 min

Vibration

Operating
Nonoperating

1.12 g from 3 to 500 Hz
2 g from 3 to 500 Hz

Regulatory compliance

ENG-5769
UL 1950
CSA 22.2-950-936
EN 60 950
BABT
AUSTEL
IEC-801
Telcordia Technologies (formerly Bellcore) NEBS TR-NWT-000063
Telcordia Technologies (formerly Bellcore) NEBS TR-NWT-001089

Dial Shelf Controller Card Specifications

Table A-7 lists dial shelf controller card environmental specifications.


Table A-7:
Dial Shelf Controller Card Environmental Specifications
Description Specification

Cooling

Maximum inlet air temperature is 131° F (55° C)

Temperature

Operating
Nonoperating

23 to 131° F (-5 to 55° C)
-13 to 158° F (-25 to 70° C)

Humidity

Operating
Nonoperating

10 to 90%, noncondensing
10 to 95%, noncondensing

Altitude

Operating
Nonoperating

9,843 ft (3,000 m) at 104° F (40° C)
15,000 ft (4,570 m) over allowable temperature range

Thermal shock

Operating

Nonoperating

23 to 113° F (-5 to 45° C at 0.5° C) per minute
-13 to 158° F (-25 to 70° C) with change-over time between 2 and 3 minutes

Vibration

Operating
Nonoperating

1.12 Grms from 3 to 500 Hz
2 Grms from 3 to 500 Hz

Ripple and noise

200 mV

Battery feed noise

3kHz band between 10KHz and 20 MHz

Voice frequency noise
Radio frequency noise

70 dBrnC
500 mV RMS

Long-term voltage drift

± -0.5%

DC PEM Specifications

The PEMs provide -48 VDC power, which is distributed through the filter module to the dial shelf backplane. The analog isolators in the filter module are provided with 15 VDC. The PEMs suffer no damage if any or all outputs have no load (no load occurs when there are no cards plugged into the backplane) or if the maximum input voltage is exceeded; however, input voltages that exceed 75 V eventually trip the PEM 60 A circuit breaker, and you might have to reset the breaker as needed.

Table A-8 lists DC output voltage and current specifications.


Table A-8: Power Entry Module Power Specifications
Power Description

Voltage to backplane

Maximum
Nominal
Minimum

-38 VDC
-48 VDC
-75 VDC

Current

Minimum (SS)
Nominal (SS)
Maximum (SS)
Peak (2 sec)

3 A
42 A
54 A
60 A

Circuit breaker

50A

Table A-9 lists the DC-input power supply environmental specifications, which are designed to meet NEC, NEBS, and ETSI requirements.


Table A-9:
Power Entry Module Environmental Specifications
Specification Description

Cooling

Maximum inlet air temperature is 131° F (55° C)

Temperature

Operating
Nonoperating

23 to 131° F (-5 to 55° C)
-13 to 158° F (-25 to +70° C)

Humidity

Operating
Nonoperating

10 to 90%, noncondensing
10 to 95%, noncondensing

Altitude

Operating
Nonoperating

9,843 ft (3,000 m) at 104° F (40° C)
15,000 ft (4,570 m) over allowable temperature range

Thermal shock

Operating
Nonoperating

23° F to 113° F (-5° C to 45° C) at 0.5° C per minute
-13° F to 158° F (-25° C to 70° C) with changeover time between 2 and 3 min

Vibration

Operating
Nonoperating

1.12 g from 3 to 500 Hz
2 g from 3 to 500 Hz

Regulatory compliance

ENG-5769
UL 1950
CSA 22.2-950-95
EN 60 950
ACA TS001, AS3260

Filter Module Specifications

Table A-10 lists the filter module DC power requirements.


Table A-10: Filter—DC Power Requirements
Description Specification

Input voltage

Minimum
Minimum/Nominal
Nominal
Maximum/Nominal
Maximum

-20 (10 mS)
-38 VDC
-48 VDC
-72 VDC
-75 (IS)

Output voltage

Maximum
Nominal
Minimum

-38 VDC
-48 VDC
-75 VDC

Current

Minimum (SS)
Nominal (SS)
Maximum (SS)
Peak (2 sec)

3 A
42 A
60 A
80 A

Circuit breaker

50 A

Table A-11 lists the filter module environmental specifications.


Table A-11:
Filter Module Environmental Specifications
Specification Description

Cooling

Maximum inlet air temperature is 131° F (55° C)

Temperature

Operating
Nonoperating

23° F to 131° F (-5° C to 55° C)
-13° F to 158° F (-25° C to 70° C)

Humidity

Operating
Nonoperating

10% to 90%, noncondensing
10% to 95%, noncondensing

Altitude

Operating
Nonoperating

9,843 ft (3,000 m) at 104° F (40° C)
15,000 ft (4,570 m) over allowable temperature range

Thermal shock

Operating
Nonoperating

23° F to 113° F (-5° C to 45° C at 0.5° C) per minute
-13° F to 158° F (-25° C to 70° C) with changeover time between 2 and 3 minutes

Vibration

Operating
Nonoperating

1.12 g from 3 to 500 Hz
2 g from 3 to 500 Hz

Ripple and noise

200 mV

Battery feed noise

3 kHz band between 10 kHz and 20 MHz

Voice frequency noise
Radio frequency noise

70 dBrnC
500 mV RMS

Long-term voltage drift

± -0.5%

Regulatory compliance

ENG-5769
UL 1950
CSA 22.2-950-95
EN 60 950
ACA TS001, AS3260
IEC-801
Telcordia Technologies (formerly Bellcore) NEBS TR-NWT-000063
Telcordia Technologies (formerly Bellcore) NEBS TR-NWT-001089

AC Power Module Specifications

The AC-input power supply operates between 200 and 240 VAC input voltage and supplies -48 VDC to the dial shelf. The AC-input power supply uses a power factor corrector (PFC) that automatically adjusts for the input voltage being supplied.

Table A-12 lists the AC-input power supply specifications.


Table A-12: AC-Input Power Supply—Specifications
Description Specification
Input
Input power requirement

2666.66 volt amps VA

Input voltage

200 to 240 VAC

Input frequency

50 to 60 Hz

Power factor

0.90 at 50% of full load; 0.99 at full load

Output

Power output

2000W with a maximum configuration and one or two AC-input power supplies

Voltage out (VO) set point:

-48.0 VDC typical. Frame ground strappable to either output terminal.

Current out (IO) rated:

0 to 41.6A DC; 2000W maximum

Output current limit
(steady state)

58.1A DC maximum

Efficiency

88% at full load, 240 VAC, with ORing diode

DC-output stud torque

25 in. lb

Environmental Characteristics

Dimensions (H x W x D)

5.25  x 17 x 14.4 in. (13.32 x 43.2 x 35.88 cm)

Weight

Per power supply: 14.5 lb (6.6 kg)

Empty power shelf: 18 lb (8.16 kg)

Heat dissipation

1037 Btu/hr

AC power cable supplied

12 AWG; 16A1

DC interconnect cable supplied

6 AWG, 2 pairs (black and red)

Storage temperature

25.8 to 185 ° F (-40 to 85 ° C)

Operating Temperature
(air inlet to power unit)

32 to 122 ° F (0 to 50 ° C) airflow front to back with 3 clearance for exhaust air in unpressurized enclosure

Acoustics

60 dBA typical; sound pressure level measured at 1 m

Humidity (noncondensing)

5% to 95%

Altitude

-200 to 13,000 ft (-61 to 3,962 m); adjust temperature at -7 ° C per 1000 ft. above 8000 ft

Shock and Vibration

Lucent L-533809

ESD

IEC1000-4-2

Reliability (at 40 ° C, 200 VAC, 1600 W)

7500 FITS per TR-EOP-000332

1.5 x 105 hours MTBF per RIN

Regulatory compliance

Agency approvals

CE
UL
CSA
VDE

For compliance information refer to the Cisco AS5800 Universal Access Server Regulatory Compliance and Safety Information document that shipped with your system.

1Each AC-input power supply requires a minimum of 15A service, with a 15A receptacle at the power source. The power cable supplied with the Cisco AS5800 AC-input power shelf uses a 16A male plug.

Enhanced Power Supply Specifications

The power supply for the enhanced AC-input power shelf operates between 200 and 240 VAC input voltage and supplies -48 VDC to the dial shelf. The power supply for the enhanced AC-input power shelf uses a power factor corrector (PFC) that automatically adjusts for the input voltage being supplied.

Table A-13 lists the specifications for the enhanced AC-input power shelf AC-input power supply.


Table A-13: Enhanced AC-Input Power Supply Specifications
Description Specification
Input
Input power requirement

2666.66 volt amps (VA)

Input voltage

200 to 240 VAC1

Input frequency

50 to 60 hertz (Hz)

Power factor

0.90 at 50% of full load; 0.99 at full load

Output

Power output

2000W with a maximum configuration and one or two AC-input power supplies

Voltage out (VO) set point:

-48.0 VDC2 typical

Current out (IO) rated:

0 to 41.6 amps DC; 2000W maximum

Output current limit
(steady state)

58.1 amps DC maximum

Efficiency

88% at full load, 240 VAC with ORing diode

DC-output stud torque

25 in. lb

Environmental Characteristics

Dimensions (H x W x D)

5.25  x 17.32 x 13.6 in. (13.32 x 44 x 34.5 cm)

Weight

Per power supply: 11 lb (5 kg)

Empty power shelf: 14 lb (6.4 kg)

Heat dissipation

7755 Btu/hr

AC power cable supplied

12 American Wire Gauge (AWG), 16-amp3

DC interconnect cable supplied

6 AWG, 2 pairs (black and red)

Storage temperature

25.8 to 185 ° F (-40 to 85 ° C)

Operating Temperature
(air inlet to power unit)

32 to 122 ° F (0 to 50 ° C) airflow front to back with clearance for exhaust air in unpressurized enclosure

Acoustics

60 dBA typical; sound pressure level measured at 1 m

Humidity (noncondensing)

5 to 95%

Altitude

-200 to 13,000 ft (-61 to 3,962 meters); derate at -7 ° C/1000 ft above 8000 ft

Shock and Vibration

Cisco Systems ENG-3396

ESD

IEC1000-4-2

Reliability (at 25 ° C, 220 VAC, 2000 W)

150k hours MTBF

Regulatory compliance

Agency approvals

CE
UL
CSA
VDE

For compliance information see the Cisco AS5800 Universal Access Server Regulatory Compliance and Safety Information document that shipped with your system.

1VAC = volts alternating current.
2VDC = volts direct current.
3Each AC-input power supply requires a minimum of 15-amp service, with a 15-amp receptacle at the power source. The power cable supplied with the Cisco AS5800 enhanced AC-input power shelf uses a 16-amp male plug.

Cabling Specifications

This section describes and provides pinout information for the cables available for the Cisco AS5800 that connect to the dial shelf, the router shelf, and power modules and supplies. For pinouts and specifications of cables that connect to dial shelf ingress cards (T1/E1, T3) refer to the Cisco AS5800 Universal Access Server Dial Shelf Card Guide.

Dial Shelf Interconnect Port Adapter Cables

The dial shelf interconnect port adapter contains a single RJ-45 receptacle, which is used to connect the router shelf to the dial shelf. The cable used for this connection is a Cisco proprietary cable, customized with jackscrews to secure the connection. You must use this specially designed cable, which shipped with your dial shelf interconnect port adapter, to connect the dial shelf to the router shelf.

Caution Disconnecting this cable while the system is operating will result in a loss of all calls.

Figure A-1 shows the dial shelf interconnect cable with jackscrew connectors.


Figure A-1: Dial Shelf Interconnect Cable with Jackscrew Connectors


AC-Input Power Shelf Cables

The AC-input power shelf is equipped with four types of cables:

The AC-input connection uses a 15A/240 VAC power cord in Europe, Asia, and North America. The 15A connectors on the AC-input power shelf are incompatible with 15A power strips used in most equipment racks and with the power source used for the router shelf.

Caution Do not plug the AC-input power shelf into the same power source as the AC router shelf.

Note Wiring codes prevent the AC-input power cable from being used with the power strips in equipment racks.

Figure A-2 shows 15-A North American power connectors.


Figure A-2: 15-Amp AC Power Cord Connector and Plug, and 15-Amp Receptacle


The European or Asian power cable is rated at 16A/250-VAC. The source-side power cable connector is either shipped to match local compliance, or wired at the installation site.

The DC interconnect cables (see Figure A-3) supplied with your AC-input power shelf attach to bus terminal studs in the AC-input power shelf using ring-lug connectors; the cables then connect to the DC terminal blocks in each PEM.


Figure A-3: DC Interconnect Cables


The monitor cable has a DB-25 connector on the AC-input power shelf end and a DB-9 connector on the dial shelf end that connects to the dial shelf filter module. Figure A-4 shows the monitor cable connectors and receptacles. The pinout of the monitor cable varies slightly between the standard and enhanced AC power shelves.


Figure A-4: Monitor Cable


Table A-14 describes the cable pinout used with the AC power shelf.


Table A-14: Monitor Cable Pinout —AC Power Shelf
DB-9 Pin Signal Description DB-25 Pin1

1

AC power failure warning signal

11

2

AC power shelf overtemperature signal

10

3

AC power shelf fault signal

9

4

Ground

8

6

Ground

13

7

Ground

19

8

Ground

19

9

AC power shelf missing module

12

1DB-25 pins not listed are not used.


hometocprevnextglossaryfeedbacksearchhelp
Posted: Tue Nov 20 17:21:03 PST 2001
All contents are Copyright © 1992--2001 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.