Product Numbers: AS53-MICA-CC=, MICA-6MOD=
This document describes how to replace the 6-port modem modules and the MICA carrier card in Cisco AS5300 access servers. The part number descriptions follow:
The carrier card contains 10 slots for modem modules: a 48-port card contains eight 6-port modules, and a 60-port card contains ten 6-port modules.
This document includes the following sections:
Use this document with the Regulatory Compliance and Safety Information publication that shipped with the Cisco AS5300.
Follow these guidelines to ensure general safety:
Safety warnings appear throughout this publication in procedures that, if performed incorrectly, may harm you. A warning symbol precedes each safety warning.
Warning
This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance and Safety Information document that accompanied this device.
Waarschuwing Dit waarschuwingssymbool betekent gevaar. U verkeert in een situatie die lichamelijk letsel kan veroorzaken. Voordat u aan enige apparatuur gaat werken, dient u zich bewust te zijn van de bij elektrische schakelingen betrokken risico's en dient u op de hoogte te zijn van standaard maatregelen om ongelukken te voorkomen. Voor vertalingen van de waarschuwingen die in deze publicatie verschijnen, kunt u het document Regulatory Compliance and Safety Information (Informatie over naleving van veiligheids- en andere voorschriften) raadplegen dat bij dit toestel is ingesloten.
Varoitus Tämä varoitusmerkki merkitsee vaaraa. Olet tilanteessa, joka voi johtaa ruumiinvammaan. Ennen kuin työskentelet minkään laitteiston parissa, ota selvää sähkökytkentöihin liittyvistä vaaroista ja tavanomaisista onnettomuuksien ehkäisykeinoista. Tässä julkaisussa esiintyvien varoitusten käännökset löydät laitteen mukana olevasta Regulatory Compliance and Safety Information -kirjasesta (määräysten noudattaminen ja tietoa turvallisuudesta).
Attention Ce symbole d'avertissement indique un danger. Vous vous trouvez dans une situation pouvant causer des blessures ou des dommages corporels. Avant de travailler sur un équipement, soyez conscient des dangers posés par les circuits électriques et familiarisez-vous avec les procédures couramment utilisées pour éviter les accidents. Pour prendre connaissance des traductions d'avertissements figurant dans cette publication, consultez le document Regulatory Compliance and Safety Information (Conformité aux règlements et consignes de sécurité) qui accompagne cet appareil.
Warnung Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu einer Körperverletzung führen könnte. Bevor Sie mit der Arbeit an irgendeinem Gerät beginnen, seien Sie sich der mit elektrischen Stromkreisen verbundenen Gefahren und der Standardpraktiken zur Vermeidung von Unfällen bewußt. Übersetzungen der in dieser Veröffentlichung enthaltenen Warnhinweise finden Sie im Dokument Regulatory Compliance and Safety Information (Informationen zu behördlichen Vorschriften und Sicherheit), das zusammen mit diesem Gerät geliefert wurde.
Avvertenza Questo simbolo di avvertenza indica un pericolo. La situazione potrebbe causare infortuni alle persone. Prima di lavorare su qualsiasi apparecchiatura, occorre conoscere i pericoli relativi ai circuiti elettrici ed essere al corrente delle pratiche standard per la prevenzione di incidenti. La traduzione delle avvertenze riportate in questa pubblicazione si trova nel documento Regulatory Compliance and Safety Information (Conformità alle norme e informazioni sulla sicurezza) che accompagna questo dispositivo.
Advarsel Dette varselsymbolet betyr fare. Du befinner deg i en situasjon som kan føre til personskade. Før du utfører arbeid på utstyr, må du vare oppmerksom på de faremomentene som elektriske kretser innebærer, samt gjøre deg kjent med vanlig praksis når det gjelder å unngå ulykker. Hvis du vil se oversettelser av de advarslene som finnes i denne publikasjonen, kan du se i dokumentet Regulatory Compliance and Safety Information (Overholdelse av forskrifter og sikkerhetsinformasjon) som ble levert med denne enheten.
Aviso Este símbolo de aviso indica perigo. Encontra-se numa situação que lhe poderá causar danos físicos. Antes de começar a trabalhar com qualquer equipamento, familiarize-se com os perigos relacionados com circuitos eléctricos, e com quaisquer práticas comuns que possam prevenir possíveis acidentes. Para ver as traduções dos avisos que constam desta publicação, consulte o documento Regulatory Compliance and Safety Information (Informação de Segurança e Disposições Reguladoras) que acompanha este dispositivo.
¡Advertencia! Este símbolo de aviso significa peligro. Existe riesgo para su integridad física. Antes de manipular cualquier equipo, considerar los riesgos que entraña la corriente eléctrica y familiarizarse con los procedimientos estándar de prevención de accidentes. Para ver una traducción de las advertencias que aparecen en esta publicación, consultar el documento titulado Regulatory Compliance and Safety Information (Información sobre seguridad y conformidad con las disposiciones reglamentarias) que se acompaña con este dispositivo.
Varning! Denna varningssymbol signalerar fara. Du befinner dig i en situation som kan leda till personskada. Innan du utför arbete på någon utrustning måste du vara medveten om farorna med elkretsar och känna till vanligt förfarande för att förebygga skador. Se förklaringar av de varningar som förkommer i denna publikation i dokumentet Regulatory Compliance and Safety Information (Efterrättelse av föreskrifter och säkerhetsinformation), vilket medföljer denna anordning.
Warning Read the installation instructions before you connect the system to its power source. |
Warning Ultimate disposal of this product should be handled according to all national laws and regulations. |
Warning Only trained and qualified personnel should be allowed to install or replace this equipment. |
Warning To ensure your safety and the safety of others, be sure the power is OFF and the power cord is unplugged before working on the router. |
Warning Before working on equipment that is connected to power lines, remove jewelry (including rings, necklaces, and watches). Metal objects will heat up when connected to power and ground and can cause serious burns or weld the metal object to the terminals. |
Follow these guidelines when working on equipment powered by electricity:
Electrostatic discharge (ESD) can damage equipment and impair electrical circuitry. It occurs when electronic printed circuit cards are improperly handled and can result in complete or intermittent failures. Always follow ESD prevention procedures when removing and replacing cards. Ensure that the chassis is electrically connected to earth ground. Wear an ESD-preventive wrist strap, ensuring that it makes good skin contact. Connect the clip to an unpainted surface of the chassis frame to safely channel unwanted ESD voltages to ground. To properly guard against ESD damage and shocks, the wrist strap and cord must operate effectively. If no wrist strap is available, ground yourself by touching the metal part of the chassis.
Caution For safety, periodically check the resistance value of the antistatic strap, which should be between 1 and 10 megohms (Mohm). |
The 6-port modem modules require Cisco IOS Release 11.2(9)P or higher.
To install the carrier card and modem modules, you will need the following tools and equipment which are not included:
This section describes how to remove a carrier card.
Caution The carrier cards are not hot-swappable (that is, you cannot remove or install them when the power to the access server is ON). Be sure to turn OFF the power to the access server before installing or removing carrier cards. Failure to do so can damage the access server. |
To remove the MICA carrier card:
Step 2 Power OFF the access server.
Step 3 On the rear panel of the access server, locate the MICA carrier card (see Figure 1).
Step 4 Loosen the two captive screws that secure the carrier card to the chassis until each screw is free of the chassis.
Step 5 Insert the feature card removal tool so that the slots in each arm of the tool are behind the shoulder of each captive screw, as shown in Figure 3, and carefully pull the removal tool toward you until the feature card slides free of the chassis.
Caution The EMI protective devices on the feature cards are designed to make the cards fit tightly. When removing the cards, they can release suddenly. Exercise caution when removing the feature cards with the removal tool. |
Step 6 Set the removed feature card aside on an ESD-preventive mat.
To remove the 6-port modem modules:
Step 2 On the carrier card, locate the 6-port modem module you will replace (see Figure 4).
Step 3 Orient the carrier card so that the modem module socket faces away from you.
Step 4 Gently pry the edges of the 6-port modem module away from the standoffs, as shown in Figure 5.
Step 5 Push the two socket latches away from the modem module, as shown in Figure 6.
Step 6 Remove the modem module from its socket, as shown in Figure 7.
To install a 6-port modem module:
Step 2 Seat the 6-port modem module in the socket and press its edges onto the standoffs, as shown in Figure 8.
To install a carrier card:
Step 2 Slide the carrier card into the slot until it touches the backplane connector.
Step 3 Align the captive screws with their holes, and then seat the carrier card completely.
Step 4 Tighten the two captive screws (Figure 9) to secure the carrier card to the chassis.
Step 5 If the access server is configured with fewer than three cards, make sure that a blank slot cover is installed over each open slot to ensure proper airflow inside the chassis.
This section describes how to configure the 6-port modem modules. Take the steps described in the following tables to configure the access server:
For a description of AT commands and registers for the 6-port modem modules, see the AT Command Set and Register Summary for MICA Six-Port Modules publication (document number 78-4533-xx), which ships with the Cisco AS5300 access server.
Step | Command | Purpose |
---|---|---|
1 | Password: <password> | Enter enable mode. Enter the password. You have entered enable mode when the prompt changes to |
2 | | Enter global configuration mode. You have entered global configuration mode when the prompt changes to |
3 | 5300(config-if)# | Place all asynchronous interfaces in a single group, so that you configure the same parameters quickly on all interfaces at one time. |
4 | | To conserve IP addresses, configure the asynchronous interfaces as unnumbered and assign the IP address of the Ethernet interface to them. |
5 | | Enable PPP1 to run on the set of interfaces in the group. |
6 | | Configure interactive mode on the asynchronous interface. |
7 | | |
8 | | Support dial-in PC clients. At the global level, define the pool of sddresses |
9 | Building configuration... | Define the group range of the interface. The number you use with the group-range command depends on the number of asynchronous interfaces you have on your access server. That is, if your access server has 48 asynchronous interfaces, you can specify group-range 1 48. If 60, specify group-range 1 60. |
1PPP = Point-to-Point Protocol. 2CHAP = Challenge Handshake Authentication Protocol. 3PAP = Password Authentication Protocol. |
Step | Command | Purpose |
---|---|---|
1 | | Enter the number of modem lines to configure. If you have 48 modems, enter line 1 48. If 60, enter line 1 60. Note: There are 12 modems on each 56K module. |
2 | | Configure the access server modems to use a default configuration string (chat script). A string of modem configuration commands is sent to the modem each time it is reset. |
3 | | Allow all protocols to be used when connecting to the line. |
4 | | Enable remote IP users running a PPP application to dial in, bypass the EXEC facility, and connect directly to the network. |
5 | | Enable both incoming and outgoing calls. |
6 | | Enable hardware flow control. |
7 | | Exit to global configuration mode. |
Step | Command | Purpose |
---|---|---|
1 | 5300(config)# isdn switch-type primary-5ess | Enter your telco's switch type. The following switch types are available: primary-4ess, primary-5ess, primary-dms100, primary-net5, primary-ntt, and primary-ts014. |
2 | | Enter controller configuration mode to configure your controller port. The controller ports are labeled 0 through 3 on the quad T1/PRI and quad E1/PRI cards. |
3 | | Enter your telco's framing type. The following framing types are available: esf, sf, crc4, and nocrc4. |
4 | | Enter your telco's line code type. The following line code types are available: ami, b8zs, and hdb3. |
5 | | Enter the clock source for the line. Configure one line as the primary or most stable clock source line. Configure the other line as the secondary clock source line. |
6 | | Configure all channels for ISDN. Enter pri-group timeslots 1-24 for T1. If E1, enter pri-group timeslots 1-31. |
7 | | Repeats steps 2 to 6 to configure the second controller. Note that the controller number is 1, instead of 0. And the clock source is secondary, instead of primary.
|
Step | Command | Purpose |
---|---|---|
1 | 5300(config-if)# | Enter serial interface configuration mode. After you have configured the controller, a corresponding D-channel serial interface is created instantly. Serial interface 0:23 is the D-channel for controller 0. You must configure each serial interface to receive incoming and send outgoing modem signaling. |
2 | | Assign an IP address and subnet mask to the interface. |
3 | | Configure all incoming voice calls to go to the modems. |
4 | %SYS-5-CONFIG_I: Configured from console by console <Return> | Return to privileged EXEC mode. When this message appears, press Return to get the |
5 | 5300# copy running-config startup-config | Save the configuration changes to NVRAM. |
To verify that the new modems are working properly, enter the following command:
5300# debug modem
You should receive a set of messages similar to the following:
May 5 18:05:12.476: MODEM_REPORT:dchan_idb=0x27EC48, call_id=0x2E64,
ces=0x1 bchan=0x15, event=0x1, cause=0x0
May 5 18:05:12.476: CSM_MODEM_ALLOCATE: slot 1 and port 0 is allocated.
May 5 18:05:12.480: MODEM_REPORT(2E64): DEV_INCALL at slot 1 and port 0
May 5 18:05:12.484: CSM: Fast Ringing On at modem slot 1, port 0
May 5 18:05:12.484: CSM_PROC_IDLE: CSM_EVENT_ISDN_CALL at slot 1, port 0
May 5 18:05:12.756: %LINK-3-UPDOWN: Interface Async48, changed state to up
May 5 18:05:13.284: CSM_PROC_IC1_RING: CSM_EVENT_MODEM_OFFHOOK at slot 1, port 0
May 5 18:05:13.288: CSM: Fast Ringing Off at modem slot 1, port 0
May 5 18:05:13.292: MODEM_REPORT:dchan_idb=0x27EC48, call_id=0x2E64,
ces=0x1 bchan=0x15, event=0x4, cause=0x0
May 5 18:05:13.296: MODEM_REPORT(2E64): DEV_CONNECTED at slot 1 and port 0
May 5 18:05:13.296: CSM_PROC_IC2_WAIT_FOR_CARRIER: CSM_EVENT_ISDN_CONNECTED at slot 1,
port 0
May 5 18:05:15.076: %LINEPROTO-5-UPDOWN: Line protocol on Interface Async48, changed
state to up
To turn off the messages, enter the command:
5300# no debug modem
If you do not turn off the messages, they will continue to display.
Cisco Connection Online (CCO) is Cisco Systems' primary, real-time support channel. Maintenance customers and partners can self-register on CCO to obtain additional information and services.
Available 24 hours a day, 7 days a week, CCO provides a wealth of standard and value-added services to Cisco's customers and business partners. CCO services include product information, product documentation, software updates, release notes, technical tips, the Bug Navigator, configuration notes, brochures, descriptions of service offerings, and download access to public and authorized files.
CCO serves a wide variety of users through two interfaces that are updated and enhanced simultaneously: a character-based version and a multimedia version that resides on the World Wide Web (WWW). The character-based CCO supports Zmodem, Kermit, Xmodem, FTP, and Internet e-mail, and it is excellent for quick access to information over lower bandwidths. The WWW version of CCO provides richly formatted documents with photographs, figures, graphics, and video, as well as hyperlinks to related information.
You can access CCO in the following ways:
For a copy of CCO's Frequently Asked Questions (FAQ), contact cco-help@cisco.com. For additional information, contact cco-team@cisco.com.
78-4520-01
Posted: Fri Jun 22 14:40:27 PDT 2001
All contents are Copyright © 1992--2001 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.