This appendix contains system or error messages that might display when you are using the Cisco 200. Most of these messages are generated by the ISDN exchange or PABX and indicate errors during initialization and connection establishment.
For information about obtaining technical assistance with your Cisco 200 product, refer to the Cisco Information Packet, which shipped with your product.
This section lists the most common Cisco 200 software errors, their causes, and recommended solutions; however, if other error messages are displayed, refer to your Cisco Information Packet for information on obtaining technical assistance.
The messages are listed in alphabetical order.
Error Message Accepted MSN contains invalid charactersExplanation The parameter ACCEPTED MSN in the ISDN200.CFG file contains invalid characters.
Recommended Action Remove the invalid characters. The following lines are valid:
ACCEPTED MSN = *
ACCEPTED MSN = digit sequence
Explanation The Cisco 200 (CISCO200.EXE) tried to accept an incoming call, but another application in the same PC was faster and took the call.
Recommended Action Remove the other application from memory.
Error Message Application registration failed; code =
code
LISTEN_REQ results in error; code =
code
GET_MESSAGE results in error; code =
code
Did not get LISTEN_CONF message
LISTEN_CONF contains error; code =
code
Installation of Signalling function failed; code =
code
Explanation Communication between ISDN200 and CAPI200 failed during initialization.
Recommended Action Unload all drivers, especially CAPI200, then reload them. If the error still occurs, try replacing the ISDN Adapter.
Error Message Authentication failed - password rejected by remote systemExplanation This system sent an incorrect password to the connecting router.
Recommended Action Ensure that the system name in the ISDN200.CFG file and the password specified in the router's section are configured correctly. Check these items on the connecting router as well.
Error Message Authentication failed - remote not configuredExplanation The connecting router is not configured for the Challenge Handshake Authentication Protocol (CHAP).
Recommended Action Either comment out the line "PASSWORD = ..." in the ISDN200.CFG file (by placing a semicolon [;] as the first character) or reconfigure the connecting router to use CHAP.
Error Message Authentication failed - remote sent incorrect passwordExplanation The connecting router sent an incorrect CHAP password.
Recommended Action Ensure that the password for this connection is set up correctly on the connecting router. Ensure that the local name is correct and the password is specified in the "Routers" section. Ensure that the passwords match exactly; passwords are case-sensitive.
Error Message Bearer service not implementedExplanation Data transfer with 64 kbps service is not available for your terminal or the destination terminal.
Recommended Action Ask your ISDN carrier or PABX representative if this service is enabled for your ISDN terminal and for your connecting router. Check the telephone number that is displayed when calling ISDN200.
Error Message Call rejectedExplanation Your call was rejected by the connecting router.
Recommended Action Ensure that your phone number is in the list of acceptable numbers on the connecting router. Check the communications at the connecting router. Some systems reject incoming calls when the origination phone number indicated by the network does not match a specified number. Ensure that the phone number equivalent on the connecting router is set up correctly.
This message can also appear if there is a dialing contention; that is, the connecting router and local system try to call at the same time. The Cisco 200 driver will wait for three seconds (the default) between dialing attempts. You can change this value to avoid contention situations by adding the following line to the "Local" section of the ISDN200.CFG file:
PAUSE BETWEEN RETRIES = seconds
Error Message Cause normal
Explanation The public exchange or your private branch exchange does not give a reason why the ISDN connection was not established. The connection may have been disabled by the exchange station.
Recommended Action Try to establish the connection again. If this message recurs, ask an engineer to reset the connection to your PABX. If you have a public ISDN interface, ask your ISDN carrier to check your connection.
Error Message COMMON ISDN API not foundExplanation The Cisco 200 program could not find the CAPI200 file during startup.
Recommended Action Ensure that the CAPI200 file is present and in your PC's path before starting Cisco 200.
Error Message connection establishment torouter
failed
Explanation This message is usually preceded by three D-channel error messages (causes).
Recommended Action Try the solutions listed by the error messages. If that does not resolve the situation, check the following items:
Explanation The connection was not established because the maximum time allowed for the establishment of the logical connection was exceeded. You may have established a connection to an unknown ISDN system. The Cisco 200 can communicate only with Cisco Systems or other PPP-compliant ISDN routers.
Recommended Action Check with your system administrator to ensure that the connecting router you are trying to access is a PPP-compliant ISDN router.
Error Message connection rejected byrouter
- cause: rejection reason
Explanation A physical connection to the connecting router was established but during the negotiation procedure your call was rejected. This error may also occur if you try to establish a connection with a non-PPP-compliant router.
Recommended Action Ensure that your workstation is on the list of acceptable numbers on the connecting router.
Error Messageconnection with
router
cannot be reactivated in current state
x
connection with
router
cannot be put to sleep in current state
x
Explanation The current connection is in an intermediate state; that is, "going up," "identifying," or "going down." The requested action cannot be invoked during these states.
Recommended Action Wait for the state to change to "activated," "sleeping," or "released" and make the request again.
Error Message Country code is missing in dialnumbernumber
Area code is missing in dialnumber number
Local code is missing in dialnumber number
Inhouse code is missing in dialnumber number
In specified dialnumber number
Explanation The router's DIALNUMBER specified in the ISDN200.CFG file has a syntax error.
Recommended Action Specify the DIALNUMBER in one of two ways:
DIALNUMBER = .5553333
DIALNUMBER = 1-408-555-3333
or
DIALNUMBER = 49-239-5553333
Error Message destination not obtainable
Explanation The ISDN connection could not be established because the destination address dialed is not valid.
Recommended Action Check the dialnumber of the connecting router in the ISDN200.CFG file and repeat the call. The number dialed will be displayed when calling ISDN200.
Error Message Destination out of orderExplanation The connecting router is not operating.
Recommended Action Ensure that the connecting router is operating and try again.
Error Message Entry 'NAME' for own configuration is missing in fileExplanation There is no name entered for your station in your ISDN200.CFG file.
Recommended Action Edit the ISDN200.CFG file and add a name to the NAME= line. For example:
NAME = MyHomeOffice
Error Message Error establishing D channel Layer 1 - Cable may be broken
Explanation A connection from your ISDN adapter to the ISDN switch could not be established.
Recommended Action Ensure that the cables to and from the NT1 and the ISDN Adapter are firmly connected and operating properly. Ensure that the ISDN connection to the exchange is operating properly.
Error Message Error establishing D channel Layer 2Explanation A D-channel layer 2 connection from your ISDN card to the ISDN switch could not be established.
Recommended Action Ensure that the ISDN line is configured correctly and that the line is configured as a multipoint line with TEI negotiation.
Error Message Error establishing D channel Layer 3 - possibly wrong protocolExplanation A D-channel layer 3 connection from your ISDN Adapter to the ISDN switch could not be established. This usually occurs if the wrong D-channel protocol has been selected.
Recommended Action Ensure that you started CAPI200 with the correct protocol specification parameter (p number). On NI1 and 5ESS lines, ensure that the SPID and directory numbers are specified correctly.
Error Message Inconsistent line foundExplanation A line in the ISDN200.CFG file contains an error. The applicable line is displayed after the message.
Recommended Action Edit the ISDN200.CFG file to fix the line.
Error Message INDICATED DIALNUMBER ofrouter
contains invalid characters
Explanation The parameter INDICATED DIALNUMBER in the "Router" section contains invalid characters.
Recommended Action Remove the invalid characters from that line. The following lines are valid:
INDICATED DIALNUMBER = IGNORE
INDICATED DIALNUMBER = string of digits
Error Message
Cisco 200 driver not found at interrupt xxxx
Cisco 200 driver not found
Explanation The CISCO200.EXE file is not present at the interrupt indicated.
Recommended Action Check the jumpers on the ISDN Adapter. Make sure they are configured for the correct interrupt. Refer to the Cisco 200 ISDN Adapter Hardware Installation and Configuration Guide.
Error Messagekeyword
too long - cut after first n
characters
Explanation The ISDN200.CFG file contains a line that has an argument with too many characters. The argument string is truncated after the given number of characters.
Recommended Action Edit the ISDN200.CFG file to reduce the number of characters.
Error Message CISCO200 found at interruptxxxx
ISDN200.EXE found
Explanation ISDN200 could not find either the Cisco 200 or a packet driver in the system's main memory.
Recommended Action Start the Cisco 200 before calling ISDN200.
Error Message Line 'INDICATED DIALNUMBER = number' must not be usedExplanation You specified one or multiple indicated dialnumbers and at the same time turned off the dialnumber check.
Recommended Action Remove the following line:
INDICATED DIALNUMBER = IGNORE
or all lines of the following form:
INDICATED DIALNUMBER = string of digits
from the router's record. For temporary attempts, you can comment out these lines by inserting a semicolon [;] in the first row of the line.
Error Message Network congestionExplanation There is congestion on the ISDN network.
Recommended Action Try to establish a connection again. If the error message recurs, contact your ISDN carrier.
Error Message Network out of orderExplanation The ISDN network is currently not operating properly.
Recommended Action Try to establish a connection again. If the error recurs, contact your ISDN carrier.
Error Message No route to specified No route to destinationExplanation The ISDN connection could not be established because the destination address dialed is not valid.
Recommended Action Check the dialnumber of the respective connecting router in the ISDN200.CFG file and repeat the action. The number dialed will be displayed when calling ISDN200.
Error Message No user respondingExplanation The connecting router is not responding.
Recommended Action Ensure that the connecting router is on, or test the dialnumber of the connecting router. Ensure that the connecting router is configured correctly to accept the incoming call.
Error Message NODE ADDRESS is setable via NET.CFG onlyExplanation The ISDN200.CFG file contains a line with the keyword "NODE ADDRESS."
Recommended Action Remove the line from the ISDN200.CFG file. Edit your NET.CFG file instead and specify the following line in the "Link Driver Cisco 200" section:
NODE ADDRESS = hexadecimal digits
Error Message NODE ADDRESS is 0 - setup entry 'NODE ADDRESS' in file NET.CFG
Explanation The NET.CFG file does not contain a specification of a NODE ADDRESS for the Cisco 200 driver.
Recommended Action Add the following line to the "Link Driver Cisco 200" section of the NET.CFG file:
NODE ADDRESS = address
Ensure that the node address is unique within the entire network.
Error Message NODE ADDRESS is 0 - setup entry 'NODE ADDRESS' in file NET.CFG NODE ADDRESS is 0 - change entry 'NODE ADDRESS' in fileExplanation These messages are most likely caused by one of the following:
Recommended Action The solutions to these problems are as follows:
NODE ADDRESS = value
Explanation This message indicates that an attempt was made to contact the connecting router. If the attempt is successful, no further messages will appear. If the attempt is unsuccessful, a more specific message might follow.
Recommended Action If no messages follow this one, you need take no action; the Cisco 200 has successfully contacted the connecting router. If other messages follow this one, refer to their explanations and recommended actions elsewhere in this appendix.
Error Message number changedExplanation The phone number of the connecting router has changed.
Recommended Action Ask your network administrator for the new phone number and change the phone number in the ISDN200.CFG file.
Error Message Old Section [ALL] is not allowed anymoreExplanation The ISDN200.CFG file contains an [ALL] section. No router section can be named [ALL].
Recommended Action Change the section name to another name.
Error Message Only one of the parameters -s, -d, -c, -a and -r may be givenExplanation You cannot use more than one parameter switch at a time.
Recommended Action Use only one of the displayed parameter switches at a time.
Error Message out of orderExplanation The connecting router is not operational.
Recommended Action Repeat the action. If the error continues to appear, check the operation of the connecting router.
Error Message Own configured DIALNUMBER too long DIALNUMBER of partner name too long INDICATED DIALNUMBER of router too long - cut after n charsExplanation The INDICATED DIALNUMBER line in the ISDN200.CFG file contains a syntax error in the keyword string.
Recommended Action Reduce the number of characters in the keyword string. Retry running CONNECT.BAT.
Error Message Parameter CHANNELS is not allowed for PPP connectionsExplanation The CHANNELS parameter is specified in the ISDN200.CFG file; however, channel bundling is not yet available with PPP.
Recommended Action Remove the CHANNELS statement from the ISDN200.CFG file.
Error Message Parameter file does not contain entry forname
Explanation The router name specified in the command line of the ISDN200.EXE program must match the partner name in the "Routers" section of the ISDN200.CFG file.
Recommended Action Compare the router name in the ISDN200.CFG file with the router name on the command line.
Error Message ISDN200.CFG file not found An error occurred reading the fileExplanation Either the ISDN200.EXE program could not find the ISDN200.CFG file or an error occurred when the ISDN200.CFG file was read.
Recommended Action Ensure that the ISDN200.CFG file is in the directory in which you installed the Cisco 200 software. If the file is missing, use an ASCII text editor to generate the ISDN200.CFG file as described in the appendix "Modifying the Cisco 200 Configuration Files" or reinstall the Cisco 200 software.
Error Message file not foundExplanation The ISDN200 program could not find the ISDN200.CFG file. Ensure that the ISDN200.CFG file is in the directory in which you installed the Cisco 200 software.
Recommended Action If the file is missing, use an ASCII text editor to generate the ISDN200.CFG file.
Error Message Parameter -i has got invalid argumentExplanation The interrupt switch -i was specified with an invalid argument, for example, an incorrect interrupt number.
Recommended Action Use -i with a hexadecimal argument (for example, -i 0x63) or a decimal argument (for example, -i 94). Be sure you leave a space between the -i and the argument.
Error Message Parameter SERVICE has invalid argumentExplanation The SERVICE parameter specified in the ISDN200.CFG file has an invalid argument.
Recommended Action Change the argument to a valid entry. Valid arguments are DATA64 (default) and DATA56.
Error Message physical connection established Timeout - connection establishment to router failedor
physical connection established logical connection establishment failed - welcome procedure errorExplanation If either message sequence displays, the maximum time allowed for the logical connection establishment has been exceeded and the connection has failed. However, the physical ISDN connection (the D channel) was established and is working properly.
Recommended Action Follow these steps to correct this situation:
Explanation The connection was disabled by the ISDN exchange due to an undefined problem in the local node.
Recommended Action Try to establish a connection again.
Error Message Remote Router name is needed to initialize Cisco 200Explanation You must specify the name of the connecting router when starting the Cisco 200.
Recommended Action Enter the following:
CONNECT routername
or include the following statement in your initialization script:
ISDN200 routername
Error Message Router name is needed to initialize Cisco 200
Explanation ISDN200 was started for the first time without additional parameters after loading the Cisco 200 software.
Recommended Action When running ISDN200 for the first time, specify the name of the connecting router. On subsequent calls, the current driver configuration will be displayed.
Error Message service not available requested fac. not subscrExplanation Data transfer with 64 kbps service is not applied to your terminal or the destination terminal.
Recommended Action Ask your ISDN carrier or the representative of your PABX if this service is enabled for your ISDN terminal and for your connecting router. Check the selected dialnumber that is displayed when running CONNECT.BAT.
Error Message The LSL is not loadedExplanation The network manager link support layer (LSL) could not be found in the PC's memory.
Recommended Action Check the CONNECT.BAT file to ensure that LSL is loaded before the Cisco 200 software is installed.
Error Message Timeout - connection establishment to router failedExplanation The establishment of a physical ISDN connection failed because the maximum time allowed for the physical connection establishment was exceeded. This is similar to a "ringing telephone" situation. The destination you tried to contact sent an alert to its switch indicating that it will take some time until the call will be accepted or rejected. An alert can take up to three minutes in an ISDN network.
Recommended Action Verify that the connecting router receives a call. Switch on Q.931 or D-channel layer 3 debug facilities to check for incoming setup messages. If the setup message is received, the connecting router is configured incorrectly and will not accept the call. If the call is not received, the network is not delivering the call. In that case, perform standard physical connection checks.
Error Message Timeout - connection with router won't sleepExplanation You tried to place the ISDN connection in a sleep state by executing ISDN200 -s. The line did not go to sleep because there is still valid traffic on the line, which reestablished the connection.
Recommended Action Wait until there is no longer any traffic on the line and try using the ISDN -s command again.
Error Message Timeout - release of connection with router is still pending - unload driverExplanation The connection could not be released when you executed ISDN200 -d. This can occur due to a malfunction of the ISDN switch or of CAPI200.EXE.
Recommended Action Unload all drivers, including CAPI200.EXE.
Error Message To establish a connection withrouter
the current partner has to be released first - use 'ISDN200 -d'
Explanation Only one connection can be used at a time. Before you can start a connection to the specified router, you must release the currently active router.
Recommended Action Release the currently active router either by entering: DCONNECT.BAT or by executing ISDN200 -d.
Error Message Too many INDICATED DIALNUMBERs specified for partnername
Explanation Too many lines with the parameter INDICATED DIALNUMBER are specified in the "Routers" section of the ISDN200.CFG file. A maximum of 16 INDICATED DIALNUMBER lines per router are allowed.
Recommended Action Reduce the number of lines accordingly.
Error Message Unallocated number Normal call clearingExplanation On NI1 and 5ESS lines, these causes are typical for SPID and directory number configuration problems on the local side.
Recommended Action Ensure that you specified the correct SPID and directory number for your ISDN line. Both values must be given as parameters loading CAPI200.
Error Message User busyExplanation The connecting router is busy.
Recommended Action Ensure that the connecting router is activated and that at least one B channel is available for data communication.
Error Message Version of ISDN200 does not match Cisco 200 versionExplanation You must use ISDN200 and Cisco 200 files from the same Cisco 200 software version. Reinstall the newest version of Cisco 200 software.
This section lists messages that might be generated by the ISDN carrier. Troubleshooting questions for these messages should be directed to the ISDN carrier (telephone company).
Error Message Access info discarded Bearer cap. not authorized Bearer cap. not impl B.cap. not pres. avail Call delivered in estab. ch Call identity in use Call rejected Call (requ.call id) cleared Channel type not impl Channel unacceptable Destination out of order Facility rejected Identified chan.not exist Incompatible destination Inv. transit network selec Invalid crn value Invalid informationelem Invalid message Invalid number format Mandatory infoelem. miss Message not compatible in call state Message type not impl/exs Network out of order No answer from alerted user No call suspended No channel available No route to destination No route to specified No user responding Non-selected user clearing Normal call clearing Normal, unspecified Number changed Only rest.dig.info.b.cap Protocol error, unspec Qual.of service unavail Recovery on timer expiry Request fac. not subscr Requested chan. not avail Requested fac. not impl Resources unavailable Response to STATUS ENQUIRY Service not available Service not implemented Susp.call ex.,bad call id Switching equip. congest Temporary failure Unallocated number Unknown informationelement User busyExplanation Error messages preceded with "0x34," such as the messages above, are generated when a physical connection cannot be established.
Recommended Action Ensure that the ISDN Adapter is properly installed and connected. If it is, contact your ISDN provider and ask to have the physical connection checked.
|