System administration messages describe the following system administration conditions:
System administration messages are displayed in the lower right corner of the system administration screen and/or the log file. The messages are arranged alphabetically. Messages which begin with variable values (numbers and filenames) appear at the end of the listing.
System administration messages are described in the following manner:
Message
Explanation An explanation of the message.
Miscellaneous messages describe the following system administration conditions:
Miscellaneous messages appear in the lower right corner of the system administration screen, and are sent to the printer and the log file (C:/log).
Miscellaneous messages are described in the following manner:
Message
Explanation An explanation of the message.
Action A description of the action the user should take.
A or D or C only
Explanation A character other than A (Add) or D (Delete) or C (Card Delete) was entered.
Access Denied
Explanation The database update was denied because you do not have the proper access level. Access level for each screen is defined within the Screen Access Configuration option. During changes to the Screen Access Configuration, this message appears after a user with Level 1, 2 or 3 access types A (add) or D (delete) in the command field. These functions are limited to Level 0 users only.
Adding Ports
Explanation All ports on a card were added to a resource group by entering the A command without specifying an individual port.
Adding Prompts to Library
Explanation The ADD command message displayed while prompt files are copied into the prompt library.
Adjusting Ports
Explanation The letter P was entered. However, the system is changing the status of the ports for this card.
Admin D-chan ACTIVATE Command Submitted
Explanation The Enter key was pressed a second time after entering an ACTIVATE command in the Cmd field. The D-channel now in the manual out-of-service state is placed in standby state.
Admin D-chan MOOS Command Submitted
Explanation The Enter key was pressed a second time after entering a MOOS command in the Cmd field. The D-channel that is in the standby state is placed into the manual out-of-service state.
Admin D-chan SWITCH Command Submitted
Explanation The Enter key was pressed a second time after entering a SWITCH command in the Cmd field. A manual D-channel switchover is now initiated.
All Function Keys Assigned
Explanation All available function keys have been assigned to menus/screens.
All Passwords Must Be Entered First
Explanation The Enter key was pressed after entering either an A or C command and a username. All password information must be entered before the database can be updated. Continue the operation by entering all passwords required.
Alpha Key Input Not Allowed
Explanation An attempt was made to type letters into this field. Only numbers are allowed.
Already In A Resource Group
Explanation A valid card location was entered, and that entry is an appropriate card type, but the port has already been assigned to a resource group.
Already in Extended Mode
Explanation An attempt was made to set the system to Extended Operational Mode, but the system has already been set to take advantage of the increased system limits.
An Alarm Exists On This XXX Card
Explanation The T1 or ISDN PRI card you are attempting to make Active has a card alarm set. The card has been placed in an auto-maintenance state and cannot be activated. You should verify the condition of the T1 or PRI streams connected to this card.
ANI Should Be 1-40
Explanation A character other than a number from 1 to 40 was entered for the number of ANI digits to be collected.
Are You Sure??
Explanation You are being prompted to press Enter again to delete a port from a group.
Backup D-channel Must Appear in Group
Explanation The Enter key was pressed after defining the primary D-channel rack, level, slot (R-L-S) address but did not add the ICC ISDN span to the interface listing. The ICC ISDN span containing the primary D-channel must be defined in both the Primary D-channel RLS and Interface RLS fields.
Backup D-channel Must Be a PRI/N Card
Explanation The span located in the backup D-channel rack, level, slot (RLS) address entered is defined in the database as a span type other than ICC ISDN span. Verify the contents of the database and enter the correct span address.
Backup D-channel Not OOS
Explanation The span located in the backup D-channel rack, level, slot (RLS) address is not in an out-of-service (OOS) state. Use the Card Summary screen to change the span status to OOS.
Bad disk seek
Explanation An error occurred while positioning within a file. This message usually indicates a corrupted file.
Bad Filename Or Wildcard
Explanation The filename and/or wildcard characters were not entered properly. Check the values and retry the operation.
Bad 'IP FIELD' in Rule xx
Explanation An invalid field was entered for the IP FIELD token. The system will default to a value of IP FIELD 1.
Bad 'WAIT TIME' in Rule xx
Explanation An invalid time was entered for the WAIT TIME token. The system will default to a 1-second wait time.
Beginning of File
Explanation The first page of log file or trace file listings is displayed on the screen.
Beginning of NFAS Configuration Table
Explanation The first NFAS group is being displayed.
Block Factor out of Range 1-32
Explanation The Block Factor value specified for the interface being configured is either 0 or > 32. Blocking factors must be between 1 and 32. Specify a value in this range for this interface.
BRC Cannot Be Put Into Diagnostic
Explanation An attempt was made to change the status of an BRC card to Diagnostic. No diagnostic utilities are provided for BRC cards and their status cannot be manually changed to Diagnostic.
BRC Not Defined In This Slot
Explanation There is no database entry for a BRC in one of the addresses specified. Check the location of both BRCs in the pair or change the database using the Card Maintenance utility (refer to the Cisco VCO/4K System Administrator's Guide for more information).
C-Bus Enabled
Explanation Informs you that the C-bus is installed and the hardware is detected.
C-Bus ERROR
Explanation Informs you that the C-bus hardware is not detected. The C-bus hardware may not be installed, or may not be installed properly. Check the hardware and attempt the operation.
Can Only Display Port For ACT Tone Card
Explanation A port on the standby DTG card has been selected for display. Only active DTG ports can be displayed. Check the address and retry the operation.
Cannot Add NBC In Non-Redundant System
Explanation An attempt was made to add an NBC card into position 1-1-2 of the Master Port Subrack of a nonredundant system. The Redundant System feature flag must be set to Y to allow redundant system configuration and operation.
Cannot Change Access Level
Explanation A user with Level 1, 2 or 3 access attempted to upgrade the access level while modifying a password. The ability to upgrade access levels is restricted to Level 0 users only.
Cannot Connect BRCs on same Subrack
Explanation The BRCs entered are both located on the same subrack. One BRC must reside in the Master Subrack and one in the Expansion Subrack.
Cannot Group ISDN & non-ISDN Types
Explanation An attempt was made to create a resource group with ISDN B-channel ports and other line/trunk type ports. ISDN B-channels cannot be grouped with non-ISDN ports. Refer to the Cisco VCO/4K ISDN Supplement for more information on ISDN PRI ports.
Cannot Set A Path On Standby DTG
Explanation An attempt was made to create a path with a port address on the Standby DTG card. Check the address and retry the operation.
Cannot Switch SBY System
Explanation An attempt was made to perform a system switchover from a console connected to the Standby system controller. Connect the console to the Active controller to perform the switchover.
Can't Change Console Device From Remote
Explanation An attempt was made to change the Local TTY setting while performing system administration from a remote terminal. The local console settings cannot be changed when you are logged in on a remote terminal.
Can't Change Status of NBC
Explanation An attempt was made to change the status of an NBC card. These cards determine their own status when they reboot and are downloaded.
Can't Connect Two 'Rcv Only' Ports
Explanation The ports entered are both for receive-only ports. Check the address and retry the operation.
Can't Connect Two 'Xmit Only' Ports
Explanation The ports entered are both for transmit-only ports. Check the address and retry the operation.
Card Already Active
Explanation An attempt was made to change the status of a card to Active when the card is already active. To reset an Active card, it must first be changed to out-of-service, then back to active.
Card Already Entered
Explanation The span indicated by the cursor location has already been specified in this or another NFAS group.
Card Containing TSA X Is OOS
Explanation The card on which the specified port resides is out-of-service. The card must be in service to create a path. Return the card to Active using the Card Maintenance option and retry the operation.
Card Does Not Support Remote Loopback
Explanation An attempt was made to change the status of a card type other than an ISDN PRI card to Remote Loopback mode. Remote loopback is only supported for PRI cards.
Card Fields Are Empty
Explanation The Display Filter's R-L-S fields are not specified.
Card Field Not Found
Explanation The card's R-L-S fields are blank while a new port value is entered.
Card Is Added, But Out Of Service!
Explanation This verification message appears when a card is added to the database.
Card Must Be Active, Diag or Campon
Explanation An attempt was made to change the status of a card to Maintenance from some status other than Active or Diagnostic. The card must be Active or in Diagnostic mode before it can be changed to Maintenance status. The card may also be in Camped On state, as ports are in transition from Active to Diagnostic mode.
Card Must Be Active, Maint or Campon
Explanation An attempt was made to change the status of a card to Diagnostics from some status other than Active or Maintenance. The card must be Active or, in the case of a T1 card, in Maintenance mode before it can be changed to Diagnostics status. The card may also be in Camped On state, as ports are in transition from Active to Diagnostic mode.
Card Must Be OOS
Explanation The user attempted to select a tone plan ID for an active SPC span. Access the Card Maintenance screen and change the SPC span to out of service (OOS), then select a tone plan ID for the OOS SPC span via the SPC-TONE Plan Configuration screen.
Card Not Out of Service
Explanation The user attempted to add an interface span which is not out-of-service (OOS), or attempted to delete the ICC ISDN span containing either the primary or backup D-channel without placing the span OOS first.
Card Not Specified
Explanation There is no data in the hardware address field.
Card Status is Changed
Explanation The system has changed the status of a card. If the status change is to Active, this message is displayed when the command is entered, but the card status does not change to Active until the card actually comes into service.
Changing Log File System
Explanation The Enter key was pressed a second time after modifying configuration settings for the Log file system. The system is attempting to store these settings in memory.
Changing Trace File System
Explanation The Enter key was pressed a second time after modifying configuration settings for the Trace file system. The system is attempting to store these settings in memory.
Classes of Service O T or 2 and A
Explanation An attempt was made to enter an invalid character for the COS field.
Classes of Service T or TA only
Explanation A COS other than T or TA was entered for a DID card.
Command Aborted
Explanation A key other than Enter was pressed when the "Press ENTER To Submit Command" message was displayed or a console timeout occurred. The operation was cancelled.
Conference XX Not Active
Explanation The conference number entered is an idle conference.
Configuration Change Aborted
Explanation A key other than Enter was pressed when the "ENTER To Confirm New Configuration" message was displayed or a console timeout occurred. The operation was canceled and no change was made to the database.
Console Stream Closed
Explanation Keyboard input processing is blocked due to an internal processing fault. Contact Cisco Systems TAC for more information.
Copying C:DBASE/filename.TBL
Explanation The database table file is being written to floppy disk during a Database Store operation.
Copying files...
Explanation The system is copying file(s). This message is followed by a message listing the number of files copied.
CPA Cannot Be Put Into Maintenance
Explanation An attempt was made to change the status of a CPA card to Maintenance. The CPA card goes into Maintenance status automatically when it comes into service. After the template information has been downloaded to it, the CPA goes to the Active status. CPA card status cannot be manually changed to Maintenance.
D-chan States Have Changed, Press REDRAW
Explanation The D-channel states have changed during the time the system administrator selected a command in the Cmd field and pressed Enter but before confirming the entry by pressing the Enter key a second time. Press the Redraw key to update the display.
Delete All Ports For This Card??
Explanation A request to delete all ports for a card from a group was sent. This message is presented as a prompt. Press the Enter key to delete the ports.
Delete Operation Aborted
Explanation The operation was aborted by pressing a key other than Enter.
Deleting files...
Explanation The system is deleting file(s). This message is followed by a message listing the number of files deleted.
Deleting Ports
Explanation The Enter key was pressed again after responding to the "Delete All Ports For This Card??" message. All ports on the card from the resource group are being deleted.
Dest IP Address Must Not Be On Local Net
Explanation Indicates that the Internet address you entered for the Destination Subnet is in the same network as that of the VCO/4K system. The Internet address is validated when the cursor moves out of the respective fields. Validation failed. The cursor is repositioned in the same field.
Digit Should Be 0-9 * #
Explanation On the Inpulse Rule Table screen, characters other than valid characters for END CHAR and CLR CHAR were entered. On the Outpulse Rules Table screen, characters other than valid characters for outpulsing in DTMF mode were entered.
Digit Should Be 1-8
Explanation A character other than a digit from 1 to 8 was entered for the tone number in the data field following an OP DIGIT token when outpulsing is done in OP TONE mode.
Digit Should Be 0-9 KP ST S1 S2 S3
Explanation Invalid characters were entered for outpulsing in MF mode.
Digits Can Be From 1 to 40
Explanation A character other than a number from 1 to 40 was entered in the additional data field following a DIGITS token.
Directory Isn't Empty
Explanation An attempt was made to delete a directory that still contains files. All files within the directory must first be deleted before deleting the directory by name.
Disk formatted.
Explanation The floppy disk in the A: drive has been formatted using the Format Disk operation.
Disk Write Error
Explanation An internal error occurred during a disk write operation. Retry the operation. If this error continues to occur, contact Cisco Systems TAC.
Download In Progress On This Card
Explanation An attempt was made to change the status of a card that is receiving an application download. The card is in Maintenance mode during the download and the card status cannot be changed until the download completes.
DTG Cannot Be Put Into Diagnostic
Explanation An attempt was made to change the status of an DTG card to Diagnostic. DTG card status cannot be manually changed to Diagnostic.
Duplicate Address/Port Combination
Explanation The Internet Address/Port values entered for the Ethernet socket being configured is already assigned to another socket. Specify a unique Internet Address/Port Address combination for this socket.
Duplicate host name
Explanation The host name specified for the interface being configured is already assigned to another interface. Specify a new host name for this interface.
Duplicate Local Port Specification
Explanation The Local Port specified for the Ethernet socket being configured is already assigned to another socket. Specify a unique local port value for this socket.
Duplicate NFAS Group Name
Explanation The user attempted to assign an NFAS group name that already exists. Each NFAS group must be assigned a unique alphanumberic name. Check the value and retype the information.
Empty RLSP!
Explanation No port address has been entered in the R-L-S-P field. Check the address and retry the operation.
Enable C-bus mode. Are you sure (Y/N)=N?
Explanation An attempt was made to enable the C-bus to take advantage of the full 4,096 ports. (The Extended Operational Mode feature must also be enabled for the system to run in 4K mode.)
End of Card Table
Explanation The final Card Summary screen is displayed, or Next Screen was pressed while the last Trunk Card Configuration screen was displayed.
End of Conference List
Explanation The last screen of conference information is being displayed.
End of File
Explanation The last page of the log file or trace file listings are displayed on the screen.
End of Group
Explanation An attempt was made to page through the resource group listing using the Next Screen key. The last screen of port listings has been reached.
End of NFAS Configuration Table
Explanation The last NFAS group is being displayed.
End of Prompt Library
Explanation The Next Screen key was pressed while the end of the prompt list was already displayed.
Enter A/D/C (Add/Delete/Change) Only
Explanation A key other than A, D or C was entered in the command field. Check the value and retype the command.
Enter Access Level 0-3
Explanation A value other than 0, 1, 2 or 3 was entered in the Access Level field. Check the value and retype the command.
Enter Conference Number
Explanation The Next Screen or Prev Screen key was pressed before a conference number was typed into the field.
ENTER To Confirm New Configuration(s)
Explanation The Enter key was pressed after modifying configuration settings. To save the displayed settings, press Enter again. To cancel the operation, press any other key.
ENTER To Confirm Switchover
Explanation The Enter key was pressed after entering the E menu selection. To switch Active system to Standby, press Enter again. To cancel the operation, press any other key.
ENTER to Delete User:
Explanation The Enter key was pressed after entering the D (delete) command and a username. To delete the user from the database, press Enter again. To cancel the operation, press any other key.
Enter Y or N only
Explanation A value other than Y or N was entered in the Display Ports (Y/N) field. Retry the operation.
Enter Y to propagate port 1 values
Explanation The SIG. TYPE, INPULSE RULE, or COS field on port 1 in the Programmable Trunk Configuration screen was selected or modified. Press Y and all remaining ports are configured with the same parameter entered for port 1.
Note Propagate parameter data does not appear for other ports until a screen refresh is performed. |
ERROR - Broadcast or Cyclic Only
Explanation An invalid option was entered in the Incoming Call Distribution field. Valid entries are Broadcast and Cyclic.
ERROR C-Bus is Enabled But it is Not Installed
Explanation The C-bus was enabled, but the C-bus hardware has not been installed. Or the AAC is not properly seated.
ERROR C-Bus is Not Installed
Explanation The C-bus mode has not been enabled and the C-bus hardware has not been installed. Or the AAC is not properly seated.
ERROR Can't Display PRI D Channel
Explanation The D-channel (port 24) on an ISDN PRI card has been selected for display. Only B-channels on ISDN PRI cards can be displayed. Check the address and retry the operation.
ERROR Cannot Add Prompt. Err = xx
Explanation For the ADD command, indicates that an error occurred during the add attempt. The VRTX operating system IFX error code is displayed in the error message.
ERROR Cannot Open File for Edit
Explanation An incorrect file name was entered in the Filename field.
ERROR: Card Already Exists
Explanation An attempt was made to add a card at a Rack-Level-Slot/Group/Span location where one already exists.
ERROR: Card Does Not Have Ports
Explanation An attempt was made to use the Port Definition command card. This card does not have ports, so the port status cannot be changed.
Error: Card Is Not Active
Explanation A bearer on a card which is not active was specified.
Error: Card Is Not a Line/Trunk Card
Explanation The specified bearer is not a line or trunk.
ERROR Card Is Not in Database
Explanation For the TEST command, indicates that the port specified by RLSP is not defined in the system database.
ERROR: Card Is Not Out Of Service
Explanation An attempt was made to delete a card that is still active. Change the card status from Active, Standby, Maintenance, or Diagnostic to out-of-service (OOS) and retry the operation.
Error - Card Not In Database
Explanation The specified card location (R-L-S) is not configured in the system.
ERROR Card Not Specified
Explanation The port address or hardware address entered does not correspond to any card in the database. Check the address and retry the operation.
Error: Channel Crosses Port Boundary
Explanation The subrate connection request has been rejected due to the subrate connection request crossing a bearer boundary.
ERROR Delete File Failed. Err = xx
Explanation For the DELETE command, indicates that an error occurred during the deletion attempt. The VRTX operating system IFX error code is displayed in the error message.
ERROR Directory Does Not Exist
Explanation Directory entry must consist of a valid device and directory path (for example, c:/pathname) on the specified disk.
Error: DISPLAY, ADD Or DELETE Only
Explanation An invalid alphanumeric string was entered for the Command field. The valid entries for this field are: DISPLAY, ADD, or DELETE.
ERROR Duplicate Library Definition
Explanation The same prompt library has been listed more than once in the list of supported prompt libraries.
Error During Disk Operation
Explanation An internal error occurred during a disk read/write operation. Check all values entered and retry the operation; if this error continues to occur, contact Cisco Systems TAC.
Error During File System Configuration
Explanation An error occurred when the system attempted to store the file system change to memory. Contact Cisco Systems TAC for more information.
ERROR: DVC/IPRC Port is Not In Correct State
Explanation The DVC or IPRC port at the indicated address is not out-of-service. Remove the port from service from the Card Maintenance screen and try the operation again.
Error: ENABLED or DISABLED Only
Explanation An invalid alphanumeric string was entered for one of the field entries on the screen. The only valid entries for these fields are ENABLED or DISABLED.
ERROR: Interface Already Exists
Explanation The Rack-Level-Slot/Group/Span entered already exists in the database. Re-enter a nonexisting entry.
ERROR: Interface Does Not Have Ports
Explanation There are no ports associated with the interface. Associate a port(s) with the interface and retry the operation.
ERROR: Interface Is Not Out Of Service
Explanation The cards in the locations specified must be taken out-of-service. Remove the port from service from the Card Maintenance screen and retry the operation.
ERROR: Interface Not In Database
Explanation The Rack-Level-Slot/Group/Span entered in not in the database. Re-enter a valid entry.
Error: Internal Allocation Error
Explanation The subrate connection request has been rejected due to an internal memory allocation error.
ERROR Invalid Call Generation R L S P
Explanation The virtual call generation port address entered contained an invalid rack/cabinet, level, slot, or port value. Only the R-L-S value of 0,0,0 and port values 1 to 256 are valid in standard operational mode, and 1 to 999 in extended mode. Check the address and retry the operation.
ERROR Invalid Card Address
Explanation The card address does not correspond to any card in the database. Check the address and retry the operation.
ERROR Invalid Card R, L, S
Explanation An invalid hardware address was entered.
ERROR Invalid Chop Range (0.0-99.9)
Explanation An attempt was made to enter an invalid entry for the End of Record Chop field. Valid values from 0.0 to 99.9.
ERROR Invalid Entry, Y or N Only
Explanation A value other than Y (Yes) or N (No) was entered in the Print Error Messages Only (Y/N) field or the Continually Loop Through Test (Y/N) field. Retry the operation.
ERROR Invalid Interval (0-24)
Explanation An attempt was made to enter an invalid entry for the Checksum Interval Timer field. Valid values are from 0 to 24.
ERROR Invalid Key
Explanation A key that is not valid for this screen was pressed, or the data was garbled when it reached the system controller. Retry the operation.
ERROR Invalid Library (1-16)
Explanation An invalid value is entered in the prompt library entry. Valid values are from 1 to 16.
ERROR: Invalid Monitor Card Type
Explanation The card specified by the Monitor hardware address is not a Call Progress Analyzer. A CPA hardware address must be specified.
ERROR: Invalid Monitor R,L,S,P
Explanation The CPA hardware address entered contained an invalid rack/cabinet, level, or slot port value. Check the address and retry the operation.
ERROR: Invalid Numeric Input (0 - 60)
Explanation An invalid value was entered for the Host Setup timer. The valid range for this field, in seconds, is 0 to 60.
ERROR Invalid PCM Limit (0-255)
Explanation An invalid value for the PCM limit parameter was specified. Valid values are from 0 to 255.
ERROR Invalid Port Address
Explanation The port address entered is outside the valid range for the system. Check the address and retry the operation.
ERROR Invalid Port Number
Explanation The hardware address entered contained a port number beyond the range of the card. Check the address and retry the operation.
ERROR Invalid Primary R, L or S
Explanation The hardware address entered as the Primary value is not a valid hardware address.
ERROR Invalid Prompt ID (1-255)
Explanation The valid range for a prompt identifier is 1-255.
ERROR Invalid R,L,S
Explanation The hardware address entered contained an invalid rack/cabinet, level, or slot port value. Check the address and retry the operation.
ERROR Invalid RLSP
Explanation The hardware address entered contained an invalid rack/cabinet, level, slot, or port value. Check the address and retry the operation.
ERROR Invalid RLSP or Port Address
Explanation The hardware address entered contained an invalid rack/cabinet, level, slot, or port value. Check the address and retry the operation.
ERROR Invalid Secondary R, L Or S
Explanation The hardware address entered as the secondary value is not a valid hardware address.
ERROR: Invalid Sender R,L,S,P
Explanation The DVC hardware address entered contained an invalid rack/cabinet, level, or slot port value. Check the address and retry the operation.
Error: Invalid Subrate Mode (1-way or 2-way)
Explanation An invalid alphanumeric string was entered for the Mode field. The valid entries for this field are 1-way or 2-way. This error may be generated during an attempt to establish or remove a subrate connection.
Error: Invalid Subrate Bit Offset (1-8)
Explanation An invalid value was entered for the bit offset that marks the start of a subrate channel within a trunk port time slot. The valid range for this field is 1 to 8. This error may be generated during an attempt to establish or remove a subrate connection.
Error: Invalid Subrate Size (8Kb, 16Kb, . . . 64Kb)
Explanation An invalid alphanumeric string was entered for the subrate channel size field. The valid entries for this field are 8 Kb to 64 Kb, in increments of 8. This error may be generated during an attempt to establish or remove a subrate connection.
ERROR Invalid Version (1-999)
Explanation The valid range for the prompt version identifier is 1-999.
ERROR IPRC Must Be OOS To Redefine Prompt Libs
Explanation An attempt was made to redefine the prompt library assignments for the IPRC while the card was active. The IPRC must be out-of-service to ensure that calls in progress are not affected by the changes.
ERROR Level Must Be 0 To 3
Explanation An invalid value was entered in one of the R-L-S-P fields. Enter a range from 0 to 3, and retry the operation.
ERROR - Major, Fatal, or Conditional Only
Explanation An invalid option was entered in the All Host Link Failure Action field. Valid entries are Major Alarm, Fatal Alarm, and Conditional Switchover.
ERROR: NBC in 1 1 1 Cannot Be Deleted
Explanation An attempt was made to delete the NBC card. This cannot be done.
ERROR NBC/BRC Does Not Have Ports
Explanation NBC and BRC cards do not have ports and therefore cannot be displayed.
ERROR No Card At This Location
Explanation The hardware address entered does not correspond to any card in the database. Check the address and retry the operation.
ERROR No Prompt Specified
Explanation For the ADD, DELETE, UPDATE, and EDIT commands, an ID and/or filename (in the fields at the bottom of the Prompt Library Maintenance screen) was not specified.
Error: No SSC In Service
Explanation The subrate connection request was rejected due to no subrate cards being in service and available to process the request.
Error: No Standby SSC To Make Active
Explanation The subrate switchover request was rejected since there is no standby SSC to become active.
ERROR No Such Prompt ID
Explanation For the EDIT, UPDATE, and DELETE commands, indicates that a prompt file specified by ID does not exist in the prompt library.
Error: Not 0 or 1's Binary Pattern!
Explanation An invalid alphanumeric was entered for one of the idle code patterns. Valid entries for an idle code pattern are 0 or 1.
ERROR: Not A CPA Port
Explanation The hardware address specified does not correspond to any CPA port. Check the address and retry the operation.
ERROR: Not A Line/Trunk Port
Explanation The hardware address specified in the Monitor fields does not correspond to a line or trunk port. Check the address and retry the operation.
ERROR: Not A Receiver Card
Explanation The hardware address specified does not correspond to any receiver card listed in the system database. Check the address and retry the operation.
ERROR: Not A Valid Port Card
Explanation The hardware address specified does not correspond to any port card listed in the system database. Check the address and retry the operation.
ERROR No Wildcards Allowed for Edit
Explanation When you use the Edit command, you can change only one prompt at a time.
ERROR Opening Prompt Library
Explanation An invalid prompt library number was entered or an error was encountered during the attempt to open the specified prompt library directory.
ERROR: Perform Operation On Card
Explanation An attempt was made to delete a Type 1 card by span (interface). You must delete Type 1 cards by rack, level, and slot. Only Type 2 cards can be deleted by rack, level, and slot/group/span. Enter only the rack, level, and slot information, and retry the operation.
Error: Port Address Not Assigned
Explanation Invalid values were entered for the rack, level, slot, or port for the R-L-S-P fields for a trunk port idle configuration.
ERROR: Port Card NOT in Diagnostic Mode
Explanation The port card specified for the test is in some mode other than Diagnostic or Camped On. Use another port card or place that card in Diagnostic mode using the Card Maintenance option.
ERROR: Port is NOT In Correct State
Explanation The CPA port at the specified address has not been deactivated. Remove the port from service from the Card Maintenance option and retry the operation.
ERROR Port is Out of Range
Explanation The port number is greater than the total number of ports on the card.
Error: Port Not Idle
Explanation The subrate connection request has been rejected due to one or both of the bearer ports being involved in another type of call.
ERROR Port NOT In Correct State
Explanation The CPA port is not deactivated. Remove the port from service from the Card Maintenance screen and retry the operation.
ERROR Ports Still In Resource Group
Explanation An attempt was made to reduce the number of playback ports supported by the IPRC, and one or more of the ports to be released are still defined in the IPRC resource group.
ERROR: Ports Still In Resource Group X
Explanation An attempt was made to delete a card which still has ports assigned to a resource group.
ERROR Primary MUST be a T1 or PRI card
Explanation The hardware address entered as the Primary value is not listed in the database as a T1 or PRI card. Check the hardware address.
ERROR Pri/Sec CANNOT Be Same Card
Explanation The hardware addresses entered as the Primary and Secondary values are on the same card (addresses are the same). Change one of the hardware addresses or leave the secondary address fields blank.
ERROR Rack Must Be 1 Or 2
Explanation An invalid value was entered for a rack/cabinet in one of the R-L-S-P fields. Valid values are 1 or 2. Retry the operation.
ERROR: Receiver Card NOT Specified
Explanation The hardware address for the receiver card was not specified.
ERROR: Receiver NOT In Diagnostic Mode
Explanation The receiver card specified for the test is in some mode other than Diagnostic or Camped On. Use another receiver card or place that card in Diagnostic mode using the Card Maintenance option.
ERROR: Receiver Port Out Of Range!
Explanation The hardware address specified for the receiver card does not correspond to any possible hardware address in the system. Check the values entered and retry the operation.
Error: Request Format Error
Explanation The subrate connection request has been rejected due to a internal message format error.
ERROR Secondary MUST be a T1 or PRI card
Explanation The hardware address entered as the Secondary value is not listed in the database as a T1 or PRI card. Check the hardware address.
ERROR: Sender NOT a DVC/IPRC
Explanation The hardware address specified does not correspond to any voice card (DVC or IPRC) listed in the system database. Check the address and retry the operation.
Error Setting Date/Time
Explanation An internal processing error occurred when the system attempted to update the system clock. If this error is displayed, no changes have been made to the system database. Retry the operation. If the problem persists, contact Cisco Systems TAC.
Error: SSC Switchover In Progress
Explanation The subrate connection request has been rejected due to a subrate card switchover in progress. The switchover should complete momentarily and the request may be resubmitted.
Error: Subrate Timeslots Exhausted
Explanation The subrate connection request has been rejected due to a timeslot exhaust condition on the subrate card.
ERROR Test Cannot Run on Standby Side
Explanation The console from which the Service Circuit Test Utility or Test Port Card function was accessed is connected to the standby controller of a redundant system. This function can only be run on the active side of a system.
ERROR: Trunk Port Out Of Range!
Explanation The hardware address specified for the port card does not correspond to any possible hardware address in the system. Check the values entered and retry the operation.
ERROR Unassigned Port Address
Explanation The port address entered does not correspond to any card in the database. Check the address and retry the operation.
Error updating configuration
Explanation An internal processing error occurred when the system attempted to update the host configuration. If this error is displayed, no changes have been made to the system database. Retry the operation. If the problem persists, contact Cisco Systems TAC.
Error: Valid Bit Offset Range 1 to n
Explanation An invalid value was entered for the bit offset that marks the start of a subrate channel within a trunk port time slot for idle configuration. Valid values depend on the particular subrate channel being changed. Table 11-1 describes valid values for n.
Subrate Channel | Valid Bit Offset (n) |
---|---|
8 Kb | 1 - 8 |
16 Kb | 1 - 7 |
24 Kb | 1 - 6 |
32 Kb | 1 - 5 |
40 Kb | 1 - 4 |
48 Kb | 1 - 3 |
56 Kb | 1 - 2 |
64 Kb | 1 - 1 |
Error: Valid Numeric Range 1-99
Explanation An invalid value was entered for the Timeslot Threshold Warning Level. The valid range for this field is 0 to 100 percent.
Error: Valid Port Number Range 1 to n
Explanation An invalid value was entered for the port in the P field for a trunk port idle configuration.
Error: Y/N Only
Explanation An invalid alphanumeric character was entered in the Refresh field. Valid entries for this field are Y (Yes) or N (No).
ERROR Y/N Only, Y to Enable Print
Explanation A value other than Y (Yes) or N (No) was entered in the Print (Y/N) field. Type a valid value, then retry the operation.
Error $XX Reading Bootstrap File
Explanation A file error has occurred in trying to read the configuration information stored in the bootstrap file; the specified device does not contain a valid BOOT.SDS file. Contact Cisco Systems TAC for more information.
Ethernet port number < 1024
Explanation The value entered for one of the Ethernet port fields (Local Port or Remote Port) is less than 1024. Values for this field must be greater than or equal to 1024. Specify a new port for this interface.
Extended Mode of Operation is Set Now
Explanation The Y and Enter keys were pressed when the Setting the Operational Mode to Extended Mode prompt appeared on the screen. (Both the Extended Operational Mode and Enable C-bus Mode features must be enabled for the system to run in 4K mode.)
Failed to Open File x:/xxx.xxx
Explanation The Enter key was pressed after typing in an incorrect path name. Enter the correct path name and press Enter.
Action Tone Files Installation/Removal
Features Table Updated
Explanation The system feature settings were successfully stored in system memory.
Field Should Be 1-24 or A or W
Explanation An invalid value was entered for the supervision template following a WAIT SUP or FINAL SUP token. Valid values are digits 1 to 24 or the letters A or W.
Field Time Should Be 1-60
Explanation An invalid value was entered for the number of seconds in the data field following a TIM FIELD token. Valid values are 1 to 60.
File Sync Has Not Completed
Explanation Applies to redundant systems. Changes to the database cannot be made during the redundancy file synchronization process. This prevents changes in the database while it is being compared with the database files on the standby side of the system.
File System(s) Successfully Configured
Explanation The configuration settings for each file system were successfully stored in system memory.
First Digit Time Should Be 1-30
Explanation An invalid value was entered for the number of seconds in the data field following the TIM FDIG token. Valid values are from 1 to 30.
Formatting A drive is Not Permitted
Explanation An attempt was made to format a floppy diskette in the A: drive. This function has been disabled.
Formatting disk...
Explanation The system is formatting a floppy diskette in the A: drive.
Function Key Not Assigned
Explanation An attempt was made to press a function key that has not been assigned to an administration screen using the Screen Access Configuration utility.
Gateway IP Address Must Be On Local Net
Explanation Indicates that the Internet address you entered for the gateway IP address is not in the same network as that of the VCO/4K system. Validation of your address entry fails. The cursor is repositioned in the same field.
Gateway Route Configuration Aborted
Action Confirms that you have aborted input by using the Exit, Prev Menu, or Main Menu keys, or that you have entered N in response to the Update Gateway Route Configuration? prompt. The Gateway Routing Configuration screen is replaced by the System Configuration screen.
Hit Any Key To Stop Update
Explanation This prompt is displayed while the screen updates are in progress.
Hit 'Select' Key To Select Card Type...
Explanation An attempt was made to type in the card type while adding a card. Use the Select key to step through the available card types.
Host Configuration Updated
Explanation The configuration settings for all host interfaces and internal overlays were successfully stored in system memory.
Illegal Source/Destination Card Address
Explanation Source or destination values must be entered before pressing the Return key to command the system for path connection.
Illegal Timeslots: Not Multiple of 8
Explanation An invalid value was entered. A timeslot value must be in an increment of 8.
Incorrect Current Password
Explanation An incorrect password was entered while attempting to delete a user or modify the password/access level. Check the password and retype the information.
Insufficient Disk Space for Live Upgrade
Explanation There is not at least 20MB of free disk space on each hard drive. Ensure that you acquire more free space on your hard drives prior to restarting Live Upgrade procedures. Access the Show Disk Free Space screen from the Disk Utilities menu.
Interface Card Must be T1 or PRI/N
Explanation The span located in the R-L-S address entered is defined in the data base as a span type other than ICC T1 or ICC ISDN span. Check the database and enter the correct span address.
Interface Is Deleted
Explanation An interface was successfully deleted by pressing the Enter key after deleting an interface with a valid location and out-of-service status.
Interface Required
Explanation For multispan cards, a span must be specified.
Initializing Trunk Card....
Explanation The trunk card is being initialized prior to starting the test.
Invalid BRC Rack Level Slot Position
Explanation An attempt was made to define a slave BRC in an invalid R-L-S hardware address (other than Slots 1 or 2 on an Expansion Port Subrack).
Invalid Card Address
Explanation The Rack/Cabinet, Level, Slot address specified for one of the BRCs does not correspond to any valid hardware address in the system.
Invalid Card Type
Explanation An attempt was made to add a card without selecting a card type.
Invalid Changes: PRI Not Out Of Service
Explanation You made a change in the Access Type, Span Type, Span Length, TRX Clock, REF Clock, CRC4, or A/Mu Law field without first having taken the ICC ISDN span out-of-service (OOS). You must take the ICC ISDN span OOS via the Card Maintenance screen before you change these fields.
Invalid Conference Number
Explanation On the Port Display screen, the Tab key was pressed to move to the conference field but there is no conference number in that field. On the Conference Display, a conference number other than a number between 1 and 128 was entered. Check the conference number and retry the operation.
Invalid Console Descriptor
Explanation Keyboard input processing is blocked due to an internal processing fault. Contact Cisco Systems TAC for more information.
Invalid Control Key
Explanation The key that was pressed on the administration keypad is not valid for this screen. Retry the operation.
Invalid Date, Enter 1 - x
Explanation An illegal value was typed into the Date field (out of the month's range, where x = 28, 29, 30 or 31 depending on the month entered). Check the value and retype the information.
Invalid Day, Enter 1 - x
Explanation An illegal value was typed into the Day field (out of the month's range, where x = 28, 29, 30, or 31 depending on the month entered). Check the value and retype the information.
Invalid Destination File
Explanation The destination device, directory and/or filename specified for the Copy Files operation are invalid. Check all values and retry the operation.
Invalid Directory Entered
Explanation A directory name that does not exist on the specified device was entered.
Invalid Escape Sequence
Explanation Keyboard characters have been garbled during a data input operation or 1 or 2 was pressed on the application keypad. Re-enter the characters.
Invalid Field Number
Explanation A character other than a digit from 1 to 4 was entered for the call record field number following an IP FIELD or OP FIELD token.
Invalid Hours, Enter 0 - 23
Explanation An illegal value was typed into the Hour field; this value must be between 0 (midnight) and 23 (11 pm). Check the value and retype the information.
Invalid Internet address format
Explanation The value entered for one of the Ethernet Internet addresses was not in the proper format. Internet addresses must be specified in decimal notation (example: 128.0.0.34). Refer to the Cisco Ethernet Guide for more information on Ethernet Internet addresses.
Invalid I/O Code
Explanation Keyboard input processing is blocked due to an internal processing fault. Contact Cisco Systems TAC for more information.
Invalid I/O Request Action
Explanation Keyboard input processing is blocked due to an internal processing fault. Contact Cisco Systems TAC for more information.
Invalid Key
Explanation A key was pressed that is not valid for this screen, or the data was garbled when it reached the system controller. Retry the operation.
Invalid Level Number
Explanation The Level number specified for one of the BRCs is not within the range allowed. Valid Level numbers in Rack/Cabinet 1 are 1 to 3. Valid Level numbers in Rack/Cabinet 2 are 0 to 3.
Invalid Maintenance Limit Entry
Explanation You entered a value in either the Slip or OOF Maintenance Limit field that was not a number between 0 and 225.
Invalid Minutes, Enter 0 - 59
Explanation An illegal value was typed into the Minutes field. Check the value and retype the information.
Invalid Operation (A or D only)
Explanation An invalid value was entered. Valid values are A or D in the Add or Delete Path (A or D) command field.
Invalid Operation Specified
Explanation A character was entered that does not correspond to any of the selections for the menu displayed.
Invalid Port
Explanation An invalid port number was entered.
Invalid Port Number
Explanation A port number was entered for a card which does not have that many ports.
Invalid Position
Explanation An attempt was made to delete a position that has no port assigned to it.
Invalid R L S P
Explanation The hardware address entered specified an invalid rack/cabinet, level, slot, or port (such as 1-4-22-30). Check the address and retry the operation.
Invalid Rack, Level, Slot
Explanation A nonexistent card location is specified. Re-enter the card location in accordance with system conventions for identifying rack/cabinet, level and slot.
Invalid Rack Level Slot Port
Explanation The previous error messages were ignored and an attempt was made to add a resource into an invalid card location.
Invalid Rack Number
Explanation The Rack/Cabinet number specified for one of the BRCs is not within the range allowed. Valid Rack/Cabinet numbers are 1 and 2.
Invalid Rack/Level Combination
Explanation A Rack/Cabinet, Level address of 1,0 was specified for one of the BRCs. There is no such address.
Invalid Scan Entry, 'Y' or 'N' Only.
Explanation A character other than Y or N was entered in the Do Bad Sector Scan During Format (Y/N)? field on the Format Disk operation screen. Only these characters are allowed for entry on this field.
Invalid Seconds, Enter 0 - 59
Explanation An illegal value was typed into the Seconds field. Check the value and retype the information.
Invalid Slot Number
Explanation The Slot number specified for one of the BRCs is not within the range allowed. Valid Slot numbers for Rack/Cabinet 1, Level 1 are 5 to 21. Valid Slot numbers for all other Rack/Cabinet, Level combinations are 1 and 2.
Invalid Source File
Explanation The source device, directory and/or filename specified for the Copy Files operation are invalid. Check all values and retry the operation.
Invalid Status Change Request
Explanation An invalid entry was typed in the Status field. Type a valid entry, then press Enter to complete the operation.
Invalid Trace Entry, 1/0 Only
Explanation A character other than 1 (activate trace) or 0 (disable trace) was entered in one of the Trace fields.
Invalid trace value entered
Explanation A character other than 0 or 1 was entered in the Trace field. Enter a valid Trace field value.
Invalid Year, Enter Year > 1990
Explanation An invalid entry was typed into the Year field; this value must be greater than 1990. Check the value and retype the information.
IPRC Cannot Be Put Into Maintenance
Explanation An attempt was made to change the status of an IPRC to Maintenance mode. The IPRC goes into Maintenance status automatically when it comes into service. After voice prompts are downloaded to it, it goes to an Active status. IPRC status cannot be manually changed to Maintenance.
IPRC Must Be OOS To Change End Rec Chop
Explanation An attempt was made to redefine the end-of-record chop data element for the IPRC while the card was active. The IPRC must be out-of-service to ensure that calls in progress are not affected by the changes.
IPRC Must Be OOS To Redefine Ports
Explanation An attempt was made to redefine the number of playback ports for the IPRC while the card was active. The IPRC must be OOS to ensure that no affected ports are involved in calls.
ISDN Not Installed
Explanation A menu selection specific to the optional ISDN PRI package was selected, but ISDN is not installed on the system.
Level 1 to 3 (Rack 1), 0 to 3 (Rack 2)
Explanation An invalid level number was entered for the rack/cabinet number previously specified.
Line X, Rcvr Y, Test Z
Explanation The line and receiver being tested (X and Y, respectively), and the cumulative number of tests run (Z) are displayed.
Log File For This Date Not Found
Explanation A valid date was specified but there is no log file for that date on the hard drive.
Major Minor Critical
Explanation An invalid option was selected for one of the Alarm Severity Configuration fields. Valid entries for the alarm severity fields are MAJOR, MINOR, or CRITICAL.
Make-Busy Threshold 0-255
Explanation An invalid entry was made in the THRESHOLDS, BUSY field. Valid values are a number from 0 to 255.
MAXRECORD Feature Has Been Disabled Due to C-bus
Explanation An attempt was made to execute the MAXRECORD token in a C-bus switch. The IPRC record function has been temporarily disabled.
Maximum Of 1920 Ports In Group
Explanation An attempt was made to add a port to a group that already has the maximum number of members (1920).
Maximum Path Limit Exceeded
Explanation An attempt was made to create a path when eight paths already exist. Delete one of the existing paths and retry the operation.
Maximum Users Already Entered
Explanation An attempt was made to add a seventeenth system user to the database. Only 16 system users can be defined in the database.
Memory Allocation Failed for Command
Explanation Memory allocation for command failed; this command will not be submitted.
Must Allocate SSC Timeslots First
Explanation Timeslots have not been allocated for subrate functionality. Allocate timeslots from the Subrate Configuration screen.
NBC and BRC Do Not Have Ports
Explanation An attempt was made to use the Port Definition command for an NBC3 or BRC. These cards do not have ports, so their port status cannot be changed.
NBC Must Be In 1-1-1 For A Side 1-1-2 For B Side
Explanation An attempt was made to add an NBC card with an R-L-S hardware address other than those listed above (the first two in the Master Port Subrack).
Need OOS to Allocate Timeslots!
Explanation An attempt was made to change the idle code configuration when the subrate card was not out-of-service.
Need OOS to Change Idle Code Config
Explanation An attempt was made to change the timeslot allocation when the subrate card was not out-of-service.
Network Status Byte: 62 RECORD_DISABLE
Explanation A record operation was attempted for the IPRC in a C-bus switch.
Network Trace Flags Modified
Explanation The Enter key was pressed after changing one or more settings in the Trace fields.
NFAS Configuration Updated
Explanation The Enter key was pressed a second time after modifying the NFAS group configuration settings. The NFAS group configuration information was successfully stored in system memory.
NFAS Group Name(s) Updated
Explanation The NFAS group name modifications were successfully stored in the system database.
No available Card Memory
Explanation You have exceeded the logical memory. There is a maximum of 240 logical numbers (0 to 239). A logical number is defined as one interface or card number.
No Available Port Memory
Explanation This prompt appears when the maximum number of timeslots in the system is reached. There are 4000 listen-only time slots and 4088 other timeslots available in a fully licensed VCO/4K. No further timeslots can be added.
No Changes Detected
Explanation The Enter key was pressed without modifying any NFAS group names. No change was made to the system database.
No Configuration Changes Were Entered
Explanation The Enter key was pressed without modifying any configuration settings. No change was made to the system database.
No Delete Performed
Explanation When prompted to press Enter again to delete a port or all ports on a card from a group, a key other than Enter was pressed.
No Features Were Changed
Explanation The Enter key was pressed before any changes were made to the system features.
No File System Changes Made
Explanation The Enter key was pressed without modifying any configuration settings. No change was made to the system database.
No Forward Tab
Explanation The Tab key was pressed while a screen that does not support this function is displayed.
No host configuration changes detected
Explanation The Enter key was pressed before any changes were made to the host configurations.
No more available Listen-Only Ports
Explanation You have exceeded the maximum 4000 listen-only timeslots available in a fully licensed VCO/4K, which indicates that you have added too many SPC type timeslots.
No more available TimeSlot Ports
Explanation You have exceeded the maximum 4088 timeslots available in a fully licensed VCO/4K. Do not include the SPC_CPA, SPC_DTMF, SPC_MFCR2, and SPC_MFRC types in your calculations for this limitation.
No Next Screen
Explanation The current display consists of only one screen.
No NFAS Group Configuration Changes Detected
Explanation The Enter key was pressed without modifying any NFAS group configuration settings. No change was made to the system database.
No Previous Card Alarms Present
Explanation The final screen of card alarms is being displayed.
No Previous Screen
Explanation The current display consists of only one screen.
No Previous Tab
Explanation The < (Back Tab) key was pressed while a screen that does not support this function is displayed.
No Room To INSERT
Explanation An attempt was made to insert a token into a rule with 16 tokens.
No Standby BRC Pair, Cannot Change State
Explanation An attempt was made to change the status of a BRC card that does not have an associated standby Master/Slave BRC pair. Because this action would eliminate bus communication to a port subrack, it is not permitted.
No Standby DTG, Cannot Change State
Explanation An attempt was made to change the status of the only DTG in the system. This DTG must remain in Active mode.
No Subsequent Card Alarms Present
Explanation The first screen of card alarms is being displayed.
No Such Rule Defined
Explanation For the configuration screens, the inpulse rule entered has not yet been defined in the database; rules must be defined before they can be assigned to a port. On the Inpulse and Outpulse Rule Table screens, a character was entered in the data field following a GOTO RULE or DO RULE token that does not correspond to an inpulse rule already stored in the database.
No Templates Were Changed
Explanation The Enter key was pressed although no changes had been made to the templates. No changes were made to the database.
No Tone Card In System
Explanation An attempt was made to create a path with a tone port address, but the system is not equipped with a DTG card.
Non-Existent Device
Explanation The device specified cannot be located by the system. Check the value and retry the operation.
Non-Existent Directory
Explanation The directory specified cannot be located on the device indicated. Check the value and retry the operation.
Non-Existent File
Explanation The filename specified cannot be located on the device and directory indicated. Check the value and retry the operation.
Not A Groupable Resource
Explanation A valid card location was entered, but that entry in the card table is not an internal service circuit.
Not A Redundant System
Explanation An attempt was made to perform a system switchover on a nonredundant system. This utility cannot be used on SDS-500 or nonredundant SDS-1000 systems.
Not A Select Field
Explanation The Select or Reverse Select key was pressed for a field that requires data entry via the main keyboard.
Not a SELECT Key Field
Explanation The Select or Reverse Select key was pressed for a field that requires data entry via the main keyboard.
Not A Selectable Field
Explanation The Select or Reverse Select key was pressed for a field that requires data entry via the main keyboard, or the Select key is not valid for this screen.
Not Allowed On SBY System
Explanation Applies to redundant systems. An attempt was made to update the system database from the standby console. Updates for host links, file system configuration, peripheral configuration, and trace configuration are the only database tables that can be configured separately for the standby system controller.
Not An Allowed Character Key
Explanation The 1 or 2 key was pressed on the Administration Keypad; any function key was pressed while the Password Check screen is displayed; a Control sequence was entered (Ctrl key followed by any other key); or the keystrokes received by the system were garbled (could indicate VDT setup is incorrectrefer to the Cisco VCO/4K Hardware Installation Guide for your hardware platform for correct settings).
Not Selectable: Uses [xxxxxxx]
Explanation You tried to make a change in either the Access Type or Switch Type field. This field has no selections for this particular span, where xxxxxxx indicates the only option available.
Not That Many Ports On Board!
Explanation The port number entered is greater than the number of ports on this card. Check the address and retry the operation.
Not Valid For This Token
Explanation An attempt was made to type data into the additional data field for a token that does not require additional data.
Null host name
Explanation No host name was specified for the interface being configured. Specify a valid host name.
Null value not allowed
Explanation The number you have entered is invalid. Enter a valid number.
Numeric Key Input Not Allowed
Explanation An attempt was made to type numbers into this field. Only letters are allowed.
One BRC Must Be In Master Subrack
Explanation Neither of the BRCs specified are in Rack/Cabinet 1, Level 1. Each BRC pair must have an MBRC in the Master Subrack.
1 file copied.
Explanation A single file was copied using the Copy Files operation.
1 file deleted.
Explanation A single file was deleted using the Delete Files operation.
1 file renamed.
Explanation A single file was renamed using the Rename Files operation.
Only BRC In Slot One Of Expansion Rack
Explanation An attempt was made to add a card other than a BRC into Slot 1 of an Expansion Port Subrack.
Only Hex/Wildcard (*/?) Input Allowed
Explanation A value other than 0 to 9, A to F or * or ? was entered in the MESSAGES fields. Check the value and retry the operation.
Only NBC In This Slot
Explanation An attempt was made to add a card other than an NBC into the R-L-S hardware address reserved only for NBC cards.
Only Yes/No (Y/N) Input Allowed
Explanation A value other than Y (Yes) or N (No) was entered in the Enable On Reboot, Reset/Clear Ports, Voice Path Trace or Print Port List field of the System Trace Configuration screen. A character other than Y or N was typed in the System Feature Configuration screen. Retry the operation.
Operation Aborted
Explanation The operation was aborted by pressing a key other than Enter in response to the Press ENTER to Clear Alarms prompt.
PA Out Of Range!
Explanation The port address entered is greater than the maximum in the system. Check the address and retry the operation.
Passwords Must Be At Least 4 Chars.
Explanation Less then 4 characters were entered in one of the password fields. All passwords must be from 4 to 12 characters in length.
Path Complete
Explanation The system has created the path requested.
Path Deleted
Explanation The system has deleted the path requested.
Pausing To Allow Carrier Alarms To Clear
Explanation The status of an ISDN PRI card has been changed from Diagnostic to Active mode. The system allows all carrier alarms to clear by pausing for approximately 10 seconds.
Please Enter "Y" or "N"
Explanation A character other than Y (Yes) or N (No) was entered in the Audible Cutoff (Y/N) field. Enter a Y or N.
Poll Timeout out of range 0 - 300
Explanation The value entered for the Poll Timeout field was greater than 300. Specify a valid poll timeout.
Port At TSA X Is Not In Correct State
Explanation The port at the specified address has not been made available. Change the port status using the P option on the Card Maintenance option and retry the operation.
Port MUST Be Greater Than Zero
Explanation The port address entered was zero. Check the address and retry the operation.
Ports Active Put In Campon
Explanation An attempt was made to change the status of a card to Diagnostics and the system determined that ports on the card are involved in calls. The card is automatically changed to Camped On status. Diagnostics can be run on this card.
Ports Still In A Group
Explanation An attempt was made to delete a card which still has ports assigned to a resource group.
Press Any Key To Halt Screen Updates
Explanation This prompt is displayed while the screen updates are in progress.
Press ENTER to Clear Alarms
Explanation The Enter key was pressed once after typing Y in the Audible Cutoff (Y/N) field. To disable external audible alarms, press Enter again. To cancel the operation, press any other key.
Press ENTER To Submit Command
Explanation The Enter key was pressed once after entering a command in the Cmd field. To implement the change, press Enter again. To cancel the operation, press any other key.
Press ENTER to update configuration
Explanation The Enter key was pressed once after modifying configuration settings. To save the displayed settings, press Enter again. To cancel the operation, press any other key.
Press ENTER To Update Group Name(s)
Explanation The Enter key was pressed once after modifying the NFAS group name listing. To save the displayed settings, press Enter again. To cancel the operation, press any other key.
Press 'ENTER' To Update Templates
Explanation The Enter key was pressed once after modifying the supervision templates. To save the templates, press Enter again. To cancel the operation, press any other key.
Press Next Screen for more alarms.
Explanation There are alarm listings in addition to those being displayed. Press Next Screen to view the additional alarms.
Press 'Y' to Confirm Change
Explanation The Enter key was pressed once after selecting a tone plan with which to configure the VCO/4K. To cancel the operation, press any other key.
PRI D Channel Not A Groupable Resource
Explanation An attempt was made to add an ISDN PRI D-channel to a resource group; these ports are not groupable resources. Refer to the Cisco VCO/4K ISDN Supplement for more information on ISDN PRI ports.
PRI D Channel Selected
Explanation The port address entered corresponds with the D-channel on an ISDN PRI card. Only B-channels on ISDN PRI cards are supported by this utility.
Primary D-channel Must Appear in Group
Explanation The Enter key was pressed after defining the primary D-channel rack, level, slot (R-L-S) address but did not add the ICC ISDN span to the interface listing. The ICC ISDN span containing the primary D-channel must be defined in both the Primary D-channel RLS and Interface RLS fields.
Primary D-channel Must Be a PRI/N Card
Explanation The span located in the primary D-channel rack, level, slot (R-L-S) address entered is defined in the database as a span type other than ICC ISDN span. Check the database using the Card Maintenance screen and enter the correct span address.
Primary D-channel Not OOS
Explanation The span located in the primary D-channel rack, level, slot (R-L-S) address entered is not in an out-of-service (OOS) state. Use the Card Summary screen to change the span status to OOS.
Print Operation Aborted
Explanation This status message appears when aborts a print operation in process. Applies to screen, database, or log file print requests.
Print Operation Completed
Explanation This status message appears when all requested material has been printed. Applies to screen, database, or log file print requests.
Printing Log File For (filename)
Explanation The name of the log file printing is displayed.
Printing Trace File For (filename)
Explanation The name of the trace file being printed is displayed.
PRI Protocol Parameters Set To Defaults
Explanation You made a change in either the Access Type or Switch Type field. When you make a change to either of these fields, all PRI protocol values are reset to the defaults.
Start of Prompt Library
Explanation The Prev Screen key was pressed while the start of the prompt list was already displayed.
Rack 1 or 2
Explanation An invalid rack/cabinet number was entered.
Rcvr X, Test Y
Explanation The receiver port being tested (X) and the cumulative number of tests run (Y) are displayed.
Reading...
Explanation The system is reading the contents of the file specified using the Display File operation.
Reading directory...
Explanation The system is reading the contents of the directory specified using the Show Directory operation.
Reading Next Format
Explanation The system is preparing data for display; the screen is blank except for the message area.
Reconfigure Your Terminal Now
Explanation The Enter key was pressed a second time after modifying the protocol configuration settings for the terminal (local or remote) that you are logged in on. Refer to the OEM documentation supplied with the terminal for instructions about configuring the terminal's protocol.
RECORD Feature Has Been Disabled Due to C-bus
Explanation An attempt was made to execute the RECORD token in a C-bus switch. The IPRC record function has been temporarily disabled.
Rehunt Threshold 0-5
Explanation A character other than a number from 0 to 5 was entered in the THRESHOLDS, RHUNT field.
Remote Log Out
Explanation A user at a remote location logged out. The system can now be accessed by a user logging in to the system via the local console.
Removing Path Between TSA XX + XX
Explanation A card has been changed from Active to another state. The system is removing a path between a port on that card and another port previously established using the Set Path function.
Renaming files...
Explanation The system is renaming file(s). A message listing the number of files renamed follows.
Reset Time out of range
Explanation The value entered for the Retry Counter was greater than 999 seconds. Specify a valid reset time value (between 60 and 999).
Retrieving Database...
Explanation The system is copying system database files from a floppy disk back onto the hard drive.
Retry Counter out of range 0-255
Explanation The value entered for the Retry Counter was greater than 255. Specify a valid retry counter value.
RLS X,X,XX Being Activated
Explanation The system is changing the status of the card specified by Rack, Level, Slot to Active. This message appears after C was entered in the command field and A was entered to activate a card.
Rule Cannot DO Itself
Explanation The same inpulse rule number being defined was entered in the data field following a DO RULE token.
Screen Access Table Updated
Explanation The access level/function key assignment changes were successfully stored in the system database.
Select Device, Enter For Display
Explanation Press the Select and Reverse Select keys to scroll through the storage device listing. Once the device is selected, press Enter to display the configuration data.
Slot 1 to 21
Explanation An invalid slot number was entered.
Speak Uses 1 255
Explanation A character other than a digit from 1 to 255 was entered for the prompt number in the data field following a SPEAK token.
Special Char Input Not Allowed
Explanation One of the following keys: : ; = > ? @ ! " # $ % & ' - . / [ _ ] ( _ ) was entered. Most fields do not accept these characters as input.
Storing Database...
Explanation The system is copying system database files from the hard drive onto a floppy disk.
Subrate Config Not Locked by User
Explanation The attempt to update the subrate configuration failed due to the configuration being locked by the SNMP administration station.
Subrate Data Is Already Locked
Explanation The attempt to update the subrate configuration failed due to the configuration being locked by the SNMP administration station.
Subrate Data Saved
Explanation The subrate switch configuration settings were successfully stored in system memory.
Subrate Path Removed from System
Explanation The selected subrate connection paths have been torn down.
Subrate Path Request Has Been Processed
Explanation The subrate connection request has been successfully completed.
Subrate Switchover Request Initiated
Explanation The subrate switchover request was accepted and the switchover has been initiated.
Supervision Template File Updated
Explanation The Enter key was pressed when the "Press 'ENTER' To Update Templates" message was displayed. The changes are being written to disk and the templates are being downloaded to the system CPA(s).
System Host Config. Updated
Explanation The system host configuration settings were successfully stored in system memory.
System Switch Initiated
Explanation The system switchover has begun. Use the status messages written to the system log files and/or printer to follow the switchover's progress of the switchover.
TeleRouter Not Installed
Explanation A menu selection specific to the optional TeleRouter software overlay was selected, but TeleRouter is not installed on the system.
Telnet Log Out
Explanation One of the following conditions caused you to be logged out:
Telnet Stream Closed
Explanation The Telnet connection was lost.
Template Update Aborted
Explanation A key other than Enter was pressed when the "Press 'ENTER' To Update Templates" message was displayed. The operation was canceled and no changes were made to the database.
Test Loop Complete ATP
Explanation The test has completed and all ports passed the test (All Tests Passed).
Test Loop Complete STF
Explanation The test has completed but that some ports failed the test (Some Tests Failed). Messages that specify the failed ports are output to the system printer.
That Username Already Exists
Explanation An attempt was made to add a new system user with a username that has already been assigned. Retry the operation with another username.
That Username Does Not Exist
Explanation An unknown username was specified while attempting to either delete a user or modify a password/access level. Check the username and retype the information.
There Are No Users Entered
Explanation D (delete) or C (change) was entered in the command field although no system users have been defined in the database.
This Card Is Not In The System
Explanation This prompt appears when the R-L-S entered for a delete, change card status, or change port status does not have a card defined in the database. Pressing any key other than Enter will abort the operation.
This Card Is Not Out of Service
Explanation An attempt was made to delete a card that is still active. Change the card status from Active, Standby, Maintenance, or Diagnostic to out-of-service and retry the operation.
This Card Type Cannot Be Displayed
Explanation A character was entered in the DISP CARD field corresponding to a bus or internal service circuit card. Only network interface cards (lines and trunks) can be displayed.
This Console Session Is No Longer Active
Explanation The Local TTY setting was changed from Console to Telnet. All local administration must now be performed over the Telnet connection (including changing the Local TTY setting back to Console).
This Does Not Match The New Password
Explanation An incorrect password was entered in the Verify Password data entry field while attempting to either delete a user or modify a password/access level. Check the password and retype the information.
This Is (resource type) Group
Explanation An attempt was made to add a port to the incorrect type. This message applies to resource groups for DCC, DTMF, MF, MFCR2, DVC, IPRC, and CPA ports. Only one group is allowed for each of these resource types, and all members must be of the same type. Possible resource types that can be displayed in the message are CONF (DCC) DTMF Receiver, MF Receiver, MFCR2 Transceiver, Announcement (DVC and IPRC) and Call Processing Analyzer (CPA).
This Is Not (resource type) Group
Explanation An attempt was made to add a port to a group, but a resource group had already been created for this port type. This message applies to resource groups for DCC, DTMF, MF, MFCR2, DVC, and CPA ports. Only one group is allowed for each of these resource types, and all members must be of the same type. Possible resource types that can be displayed in the message are CONF (DCC), DTMF Receiver, MF Receiver, MFCR2 Transceiver, Announcement (DVC) and Call Progress Analyzer (CPA).
This is the first page of this screen
Explanation The Prev Screen key was pressed while the first page of the configuration was displayed.
This is the last page of this screen
Explanation The Next Screen key was pressed while the last page of the configuration was displayed.
This Rule Is Full
Explanation An attempt was made to insert a token into a rule with 16 tokens.
This Telnet Session Is No Longer Active
Explanation The Local TTY setting was changed from Telnet to Console. All local administration must now be performed via the master console (including changing the Local TTY setting back to Telnet).
This Token Already Empty
Explanation The Insert key was pressed when the cursor was already located in a blank field.
This Type Is Not Compatible To The Slot
Explanation An attempt was made to enter a card that is not compatible with a designated slot.
Time Should Be 1 - 10
Explanation On the Inpulse Rule Table screen, characters other than a number from 1 to 10 were entered for the number of seconds for a WAIT TIME or TIM INTER token. On the Outpulse Rule Table screen, characters other than a number from 1 to 10 were entered for the number of 250-millisecond intervals for a WAIT TIME token.
Time Should Be 1 - 60
Explanation Characters other than a number from 1 to 60 were entered for the number of seconds for a TIME SUP token.
Timeout Entering Password
Explanation An entry was typed in the Password field on the login screen, but Return was not pressed within 60 seconds. The screen is redrawn and both the Username and Password fields revert to blanks.
Timeout Entering Username
Explanation An entry was typed in the Username field on the login screen, but Return was not pressed for 60 seconds. The screen is redrawn and the Username field reverts to blanks.
Timeout error during update
Explanation When the system attempted to update the link configuration and reset the link, an error caused the operation to fail. Check all configuration values and retry the operation. If the problem persists, contact Cisco Systems TAC.
Timeslot Capacity Exceeded!
Explanation A timeslot value was selected that was beyond the amount of resources available.
To Delete Card, Depress Enter!
Explanation An attempt was made to delete a card with a valid location and out-of-service status. This message appears as a confirmation prior to deleting the card.
Tone Configuration Changed!
Explanation The Y key was pressed to confirm a tone plan configuration change.
Tone Should Be 0 - 1 Or 3 - 7 Or 9 - 63
Explanation A character other than a digit was entered in the specified range for the tone number in the data field following a TONE ENAB, TONE FDIG, TONE END, or TONE CLR token.
Tone Should Be 0 - 63
Explanation A character other than a digit from 0 to 63 was entered for the tone number in the data field following a TONE NOW token.
Trace Configuration Updated
Explanation The configuration settings for message tracing operations were successfully stored in system memory.
Trace File For This Date Not Found
Explanation A valid date was specified but there is no trace file for that date on the hard drive.
Trace Flags Modified
Explanation The Enter key was pressed after changing one or more settings in the Trace fields.
TSA X Not Assigned
Explanation The port address entered does not correspond to any card in the database. Check the address and retry the operation.
Type Port Numbers, Then Depress Enter!
Explanation This prompt appears when the system has accepted a valid card location for assigning the number of available ports on a card in the system, or for changing port status. Press Next Field and type in the port numbers or blanks. Press Enter to assign the ports.
Type Status, Then Depress Enter!
Explanation This prompt appears when the system has accepted a valid card location and card type for changing the status of a card in the system. Type A, S, O, D, M or R and press Enter to complete the operation. Pressing any key other than Enter aborts the operation.
Unable To Close Card Table On Disk
Explanation A file error occurred when the system attempted to close the database card table. A detailed error message is sent to the printer.
Unable To Close Conference Table On Disk
Explanation A file error occurred when the system attempted to close the conference table (resource group conference ports are linked together in the conference table). A detailed error message is sent to the printer.
Unable To Close Port Table On Disk
Explanation A file error occurred when the system attempted to close the database port table (resource group ports are linked together in the port table). A detailed error message is sent to the printer.
Unable To Close Resource Group Table
Explanation A file error has occurred when trying to close the database resource group table on disk. A detailed error message is sent to the printer.
Unable To Close Rules Table On Disk
Explanation A file error occurred while trying to close the Inpulse or Outpulse Rule Table file on disk. A detailed error message is sent to the system printer.
Unable To Unmount Disk
Explanation The system encountered an error when dismounting the floppy diskette following a database store/retrieve operation. Retry the operation. If this error continues, contact Cisco Systems TAC.
Unable To Update Card Table On Disk
Explanation A file error occurred when the system attempted to access the database card table. A detailed error message is sent to the printer.
Unable To Update Conference Table On Disk
Explanation A file error occurred when the system attempted to access the database conference table (resource group conference ports are linked together in the conference table). A detailed error message is sent to the printer.
Unable To Update Port Table On Disk
Explanation A file error occurred when the system attempted to access the database port table (resource group ports are linked together in the port table). A detailed error message is sent to the printer.
Unable To Update Resource Group On Disk
Explanation A file error occurred when the system attempted to access the database resource group table. A detailed error message is sent to the printer.
Unable To Update Rules On Disk
Explanation A file error occurred while trying to access the Inpulse or Outpulse Rule Table file on disk. A detailed error message is sent to the system printer.
Undefined Path
Explanation An attempt was made to delete a path that has not been defined. Check the addresses and retry the operation.
Unexpected Port, State Not Changed
Explanation An attempt was made to activate a port using the P command, but did not specify the correct port value. Each two-digit port field corresponds to a specific port number; a number was entered that did not match the correct port number for that field.
Unknown I/O Error
Explanation An internal processing error has occurred on the system. Contact Cisco Systems TAC.
Unknown Password
Explanation The entry in the login Password field is not valid for the username entered. Enter the password assigned to the username via the Password Configuration utility.
Unknown Username
Explanation The entry in the login Username field is not defined in the system database. If no usernames/passwords have been defined, type admin and press Return twice to log into the system. Otherwise, enter a valid username defined in the database via the Password Configuration utility.
Unsupported Terminal Type
Explanation An internal processing error has occurred on the system. Contact Cisco Systems TAC.
Update Aborted
Explanation A key other than Enter was pressed when the "Press ENTER To Update Group Name(s)" message was displayed or a console timeout occurred. The operation was canceled and no change was made to the database.
Update cancelled
Explanation A key other than Enter was pressed after changes were made to the host configuration. A key other than Enter was pressed when the "Press ENTER To Update Configuration" message was displayed or a console timeout occurred. The operation was canceled and no change was made to the database.
Update Gateway Route Configuration (Y/N)?
Explanation Asks for confirmation to update the configuration based on the data you entered. If you enter N, the Gateway Routing Configuration screen is replaced by the System Configuration screen.
Use ENTER To Change Master Timing Link
Explanation Prompts for confirmation of the Master Timing Link change. If any key other than Enter is pressed, the change is aborted.
Use SELECT Key For This Field
Explanation A key other than Select or Reverse Select was pressed.
User <username> Logged In On Console
Explanation An attempt was made to log in from the remote console when the local console is already in use. Only one console can be logged in at a time.
User <username> Logged In On Remote
Explanation An attempt was made to log in from the local console when the remote console is already in use. Only one console can be logged in at a time.
Usernames Must Be At Least 3 Chars.
Explanation An entry with less than 3 characters was typed in the Username field. All usernames must be from 3 to 15 characters in length.
Valid Subrate Timeslot Range: 8 to XXXX
Explanation An invalid value was entered for the Timeslots Allocated For Subrate field. For 2K systems, the valid range for this field is 8 to 2048 time slots in multiples of 8. For 4K systems, the valid range for this field is 8 to 4096 time slots in multiples of 8.
XX bytes free on [device]
Explanation The of number free bytes on the specified disk device is displayed.
XX files.
Explanation The number of files that are in the selected directory is displayed.
XX files copied.
Explanation The number of files that were copied using the Copy Files operation is displayed.
XX files deleted.
Explanation The number of files that were deleted using the Delete Files operation is displayed.
XX files renamed.
Explanation The number of files that were renamed using the Rename Files operation is displayed.
The following messages pertain to software and system errors.
CODERR: ../source/api_slot_table.c, 1180, 22
Explanation A software error was detected.
Action Contact Cisco Systems TAC.
CODERR: RS_state_machine_front calling error_action
Explanation Advisory message for the Subrate Card and its state machine handlingsynchronization of the Subrate application's active and standby communication for redundancy management.
Action This message can be service affecting only if you use a Subrate card in the VCO/4K. If so, contact TAC. Otherwise, this message is not service affecting and should be ignored.
SYSERR: ../source/api_slot_table.c, 790, 21
Explanation A system error was detected.
Action Contact Cisco Systems TAC.