This chapter lists system requirements for using the France country feature package on SDS and VCO platforms operating with system software V3.x through V5.x. These requirements are categorized by hardware, firmware, and software.
This supplement also describes the components of the France country feature package:
Note Service circuit cards must occupy only one resource group in the Resource Group Summary screen; further, different card types cannot share the same resource group. Use either the SPC or the CPA card (but not both) if your system requires CPA service circuit functionality. |
Refer to the Cisco VCO/4K Tone Plan Release Notes for information on the A-law and Mu-law rules and timing rules governing the hardware configurations of cards with jumpers or dual in-line packages (DIP) switches, and the software configurations of cards without jumpers or DIPs.
Refer to the Cisco VCO/4K Card Technical Descriptions for each service circuit card and for each network card for jumper and DIP switch settings.
Refer to the Cisco VCO/4K Tone Plan Release Notes for information on system firmware requirements particular to the France country feature package.
Refer toyour system release notes for step-by-step instructions to install firmware on either the DTG-2 mezzanine card or DTG card.
Refer to the Cisco VCO/4K Tone Plan Release Notes for information on system software requirements particular to the France country feature package.
System software V5.1 FSR00 PUN24 or higher, is required to operate the France SPC software on the SPC.
Your country feature package includes a 3.5-inch diskette which contains the POST_P24 directory. The POST_P24 directory contains the following Call Progress Analyzer (CPA) and Service Platform Card (SPC) download files:
cpa.dwn
cpa.nor
cpa.spc
cpa.sit
cpa.ctg
dtmf.spc
Copy the diskette's contents to your system's C:/BOOT directory. You must be using system software V5.1 FSR00 PUN24 or higher.
If you are using system software V5.1 FSR00 PUN23 or lower, copy only the cpa.dwn file to the C:/BOOT directory.
Refer to the Cisco VCO/4K System Administrator's Guide for step-by-step instructions to copy the above files to your system's C:/BOOT directory.
Caution Always wear a wrist strap when installing software and handling system components. |
The files are now loaded onto your hard disk. Complete the installation by loading the files from the hard disk to the cards. The method of loading depends on whether it is for a new installation or for an existing installation. For new installations, refer to the "Loading the Software onto CardsNew Installations" section; for existing installations, refer to the "Loading the Software onto CardsExisting Installations" section. Refer to the Cisco VCO/4K System Administrator's Guide as you complete the installation procedure.
To load files from the hard disk to cards on a new installation, follow these steps:
Step 1 Access the Card Maintenance screen from the Maintenance Menu screen, and add the CPA (displayed as Call Progress Analyzer) or the SPC (displayed as either SPC-CPA or SPC-DTMF) to the database by using the A command, if you have not already done so.
Step 2 Insert your card, either the CPA or the SPC, into the appropriate slot. The card automatically runs internal diagnostics. One of two results follow, dependent upon which card you have inserted.
Caution Do not unseat or otherwise disturb the card while running internal diagnostics. |
Step 3 Activate the card using the C command from the Card Maintenance screen. The card takes the download. The service circuit spans are active, as can be seen from the Card Maintenance screen
Caution Do not unseat or otherwise disturb the card while it is downloading. |
Step 4 Verify that the FRM225, FRM226, FRM241, and FRM242 messages appear in your log file, to ensure that the card has taken the download.
For the SPC, verify that two additional messages appear in the log file"Begin downloading spec file C:/boot/xxx.xxx" and "End downloading spec file C:/boot/xxx.xxx". The CPA does not have these, or any other, additional log file messages.
Step 5 Create a resource group for the CPA or the SPC service circuits.
You have completed the software installation.
To load files from the hard disk to cards on an existing installation, follow these steps.
Caution This process disrupts in-progress calls and removes service circuits from operation for a few minutes. |
Step 1 If you have not already done so, access the Card Maintenance screen from the Maintenance Menu screen, and take either the CPA card or the SPC service circuits out of service (OOS).
If you have a CPA, unseat it, wait 15 seconds, and then insert the card into its slot.
Step 2 From the Card Maintenance screen, use the C command to activate the CPA or the various SPC service circuits.
Caution Do not unseat or otherwise disturb the card while it is downloading. |
Step 3 Verify that the following messages appear in the log file, to ensure that the card has taken the download. The messages you need to verify depend upon which card type you are using.
Note The SPC does not take a redownloading of the spc.dwn file. |
You have completed the software installation.
This section lists typical system software configurations that are used with the France country feature package. For more information on how to use and configure the various system software screens and menus, refer to the Cisco VCO/4K System Administrator's Guide.
Special considerations pertain to the following Database Administration menus and screens.
The Card Summary menu displays the status and port availability of E1, 4xE1, and ICC cards. To assign operating characteristics to E1 spans, access the Configuration screen for that card from the Card Summary menu.
Note The term "E1 span" designates E1, 4xE1 cards, and ICC cards with associated ICC-E1-I/O module. |
To optimize outgoing call system performance, group E1 span outgoing ports into one or more resource groups.
For information about inpulse and outpulse rule tokens, refer to the Cisco VCO/4K System Administrator's Guide.
Refer to the "Tone Detection" section for information on the answer supervision template function.
Special considerations pertain to the following Maintenance screen.
Use the Card Maintenance screen to add, delete, or change the card/port status for E1 spans. When you add an E1 span to the Card Maintenance screen, its span type is set to CAS/R2 by default.
For E1 spans set to CAS/R2, ports 1 and 17 of the card's 32 ports are reserved. Port 1 (Channel 0) carries the frame alignment pattern, remote alarm indication bit, and national-use bits. Port 17 (Channel 16) carries the multiframe alignment pattern, extra bits, and channel-associated signaling bits.
For 4xE1 and ICC cards, set the span type to CCS/31B from the Card Summary menu in order to use port 17 as a bearer port. Use E1-31B firmware on E1 cards in order to use port 17 as a bearer port.
Special considerations pertain to the following Diagnostics screens.
The Card Display screen lists the operating status of E1 spans. Information on the Card Display screen varies according to card type and span type.
The Port Display screen lists the processing states, rule processing, links, paths, and digit collection activity of E1 spans.
The Test Port Card screen tests individual E1 channels. A path is set up between three elementsthe selected E1 channel(s), the Service Platform Card-Dual Tone Multi-frequency (SPC-DTMF) card or DTMF Receiver Card (DRC), and a Digital Tone Generator (DTG) channel. The system compares the signals sent by the DRC with the signals received by the SPC-DTMF or DRC and reports discrepancies. You can test all channels on E1 spans with one command. Once you select an E1 span for port card diagnostic tests, the span enters a local loopback mode and sends out an all 1s (ones) pattern.
The Test Service Circuit screen tests DRC and SPC-DTMF service circuits.
The host commands and reports are documented in the Cisco VCO/4K Standard Programming Reference and the Cisco VCO/4K Extended Programming Reference.
Posted: Sat Sep 28 20:30:14 PDT 2002
All contents are Copyright © 1992--2002 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.