Transceiver Speed
|
Cable Type
|
Max. Distance Between Stations
|
10/100-Mbps Ethernet
|
Category 5 UTP
|
328 feet (100 m)
|
100-Mbps Ethernet
|
Multimode fiber
|
1640 feet (500 m)
|
1000-Mbps Ethernet
|
Multimode fiber
|
1640 feet (500 m)
|
1000-Mbps Ethernet
|
Single-mode fiber
|
16404 feet (5 km)
|
25-Mbps ATM
|
Category 5 UTP
|
328 feet (100 m)
|
155-Mbps ATM
|
Single-mode fiber, long reach
|
25 miles (40 km)
|
155-Mbps ATM
|
Multimode fiber
|
1.2 miles (2 km)
|
622-Mbps ATM
|
Single-mode fiber
|
9 miles (15 km)
|
622-Mbps ATM
|
Single-mode fiber, long reach
|
25 miles (40 km)1
|
622-Mbps ATM
|
Multimode fiber
|
1640 feet (500 m)
|
T1, 1.544-Mbps ATM
|
Category 5 twisted-pair
|
650 feet (198 m)
|
E1, 2.048-Mbps ATM
|
Category 5 twisted-pair and FTP (120 ohm)
|
650 feet (198 m)
|
E1, 2.048-Mbps ATM
|
Coaxial cable (75 ohm)
|
650 feet (198 m)
|
CDS3, 45-Mbps
|
Coaxial cable
|
450 feet (137 m)
|
CE1, 2.048-Mbps ATM
|
Category 5 twisted-pair
|
650 feet (198 m)
|
CES T1
|
Category 5 twisted-pair and FTP
|
650 feet (198 m)
|
CES E1
|
Category 5 twisted-pair and FTP (120 ohm)
|
820 feet (250 m)
|
CES E1
|
Coaxial cable (75 ohm)
|
650 feet (198 m)
|
DS3, 45-Mbps
|
Coaxial cable
|
450 feet (137 m)
|
E3, 34-Mbps
|
Coaxial cable
|
1299 feet (396 m)
|
If you are attaching a short cable to the 622-Mbps long-reach port adapter, you must add 10 dB of attenuation to the cable or the transmitter might overdrive the receiver and introduce data errors.
|
Pinouts to RJ-45 Connectors
The 10/100 Mbps Ethernet interface module with unshielded twisted-pair (UTP) ports supports RJ-45 connectors. The following table lists the signals for RJ-45 cable connectors.
Pin
|
Signal
|
Description
|
1
|
RxD+
|
Receive data +
|
2
|
RxD-
|
Receive data -
|
3
|
NC
|
No connection
|
4
|
NC
|
No connection
|
5
|
NC
|
No connection
|
6
|
NC
|
No connection
|
7
|
TxD+
|
Transmit data +
|
8
|
TxD-
|
Transmit data -
|
Pinouts to RJ-48c Connectors
The T1, E1, CES T1, and CES E1 port adapters support RJ-48c connectors. The following table lists the signals for RJ-48c connectors.
Pin
|
Description
|
1
|
Receive ring
|
2
|
Receive tip
|
3
|
No connection
|
4
|
Transmit ring
|
5
|
Transmit tip
|
6
|
No connection
|
7
|
No connection
|
8
|
No connection
|
Pinout Information
96-Pin Molex to 12 Unshielded RJ-45 Connectors
The 25-Mbps port adapter supports a 96-pin Molex to 4 unshielded RJ-45 connectors. The following table lists the signals for the 96-pin Molex connector.
Signal
|
Molex Pin No.
|
RJ-45 Port No.
|
RJ-45 Pin No.
|
Description
|
RXA3
|
1
|
3
|
1
|
Receive data +
|
RXB3
|
2
|
3
|
2
|
Receive data -
|
GND
|
3
|
NC
|
NC
|
No connection
|
GND
|
4
|
NC
|
NC
|
No connection
|
TXA3
|
5
|
3
|
7
|
Transmit data +
|
TXB3
|
6
|
3
|
8
|
Transmit data -
|
GND
|
7
|
NC
|
NC
|
No connection
|
GND
|
8
|
NC
|
NC
|
No connection
|
RXA7
|
9
|
7
|
1
|
Receive data +
|
RXB7
|
10
|
7
|
2
|
Receive data -
|
GND
|
11
|
NC
|
NC
|
No connection
|
GND
|
12
|
NC
|
NC
|
No connection
|
TXA7
|
13
|
7
|
7
|
Transmit data +
|
TXB7
|
14
|
7
|
8
|
Transmit data -
|
GND
|
15
|
NC
|
NC
|
No connection
|
GND
|
16
|
NC
|
NC
|
No connection
|
RXA11
|
17
|
11
|
1
|
Receive data +
|
RXB11
|
18
|
11
|
2
|
Receive data -
|
GND
|
19
|
NC
|
NC
|
No connection
|
GND
|
20
|
NC
|
NC
|
No connection
|
TXA11
|
21
|
11
|
7
|
Transmit data +
|
TXB11
|
22
|
11
|
8
|
Transmit data -
|
GND
|
23
|
NC
|
NC
|
No connection
|
GND
|
24
|
NC
|
NC
|
No connection
|
RXA10
|
25
|
10
|
1
|
Receive data +
|
RXB10
|
26
|
10
|
2
|
Receive data -
|
GND
|
27
|
NC
|
NC
|
No connection
|
GND
|
28
|
NC
|
NC
|
No connection
|
TXA10
|
29
|
10
|
7
|
Transmit data +
|
TXB10
|
30
|
10
|
8
|
Transmit data -
|
GND
|
31
|
NC
|
NC
|
No connection
|
GND
|
32
|
NC
|
NC
|
No connection
|
RXA6
|
33
|
6
|
1
|
Receive data +
|
RXB6
|
34
|
6
|
2
|
Receive data -
|
GND
|
35
|
NC
|
NC
|
No connection
|
GND
|
36
|
NC
|
NC
|
No connection
|
TXA6
|
37
|
6
|
7
|
Transmit data +
|
TXB6
|
38
|
6
|
8
|
Transmit data -
|
GND
|
39
|
NC
|
NC
|
No connection
|
GND
|
40
|
NC
|
NC
|
No connection
|
TXB2
|
41
|
2
|
8
|
Transmit data -
|
TXA2
|
42
|
2
|
7
|
Transmit data +
|
GND
|
43
|
NC
|
NC
|
No connection
|
GND
|
44
|
NC
|
NC
|
No connection
|
RXB2
|
45
|
2
|
2
|
Receive data -
|
RXA2
|
46
|
2
|
1
|
Receive data +
|
GND
|
47
|
NC
|
NC
|
No connection
|
RXA6
|
48
|
NC
|
NC
|
No connection
|
RXA1
|
49
|
1
|
1
|
Receive data +
|
RXB1
|
50
|
1
|
2
|
Receive data -
|
GND
|
51
|
NC
|
NC
|
No connection
|
GND
|
52
|
NC
|
NC
|
No connection
|
TXA1
|
53
|
1
|
7
|
Transmit data +
|
TXB1
|
54
|
1
|
8
|
Transmit data -
|
GND
|
55
|
NC
|
NC
|
No connection
|
GND
|
56
|
NC
|
NC
|
No connection
|
RXA4
|
57
|
4
|
1
|
Receive data +
|
RXB4
|
58
|
4
|
2
|
Receive data -
|
GND
|
59
|
NC
|
NC
|
No connection
|
GND
|
60
|
NC
|
NC
|
No connection
|
TXA4
|
61
|
4
|
7
|
Transmit data +
|
TXB4
|
62
|
4
|
8
|
Transmit data -
|
Signal
|
Molex Pin No.
|
RJ-45 Port No.
|
RJ-45 Pin No.
|
Description
|
GND
|
63
|
NC
|
NC
|
No connection
|
GND
|
64
|
NC
|
NC
|
No connection
|
RXA9
|
65
|
9
|
1
|
Receive data +
|
RXB9
|
66
|
9
|
2
|
Receive data -
|
GND
|
67
|
NC
|
NC
|
No connection
|
GND
|
68
|
NC
|
NC
|
No connection
|
TXA9
|
69
|
9
|
7
|
Transmit data +
|
TXB9
|
70
|
9
|
8
|
Transmit data -
|
GND
|
71
|
NC
|
NC
|
No connection
|
GND
|
72
|
NC
|
NC
|
No connection
|
RXA8
|
73
|
8
|
1
|
Receive data +
|
RXB8
|
74
|
8
|
2
|
Receive data -
|
GND
|
75
|
NC
|
NC
|
No connection
|
GND
|
76
|
NC
|
NC
|
No connection
|
TXA8
|
77
|
8
|
7
|
Transmit data +
|
TXB8
|
78
|
8
|
8
|
Transmit data -
|
GND
|
79
|
NC
|
NC
|
No connection
|
GND
|
80
|
NC
|
NC
|
No connection
|
TXB5
|
81
|
5
|
8
|
Transmit data -
|
TXA5
|
82
|
5
|
7
|
Transmit data +
|
GND
|
83
|
NC
|
NC
|
No connection
|
GND
|
84
|
NC
|
NC
|
No connection
|
RXB5
|
85
|
5
|
2
|
Receive data -
|
RXA5
|
86
|
5
|
1
|
Receive data +
|
GND
|
87
|
NC
|
NC
|
No connection
|
GND
|
88
|
NC
|
NC
|
No connection
|
TXB0
|
89
|
0
|
8
|
Transmit data -
|
TXA0
|
90
|
0
|
7
|
Transmit data +
|
GND
|
91
|
NC
|
NC
|
No connection
|
GND
|
92
|
NC
|
NC
|
No connection
|
RXB0
|
93
|
0
|
2
|
Receive data -
|
RXA0
|
94
|
0
|
1
|
Receive data +
|
GND
|
95
|
NC
|
NC
|
No connection
|
GND
|
96
|
NC
|
NC
|
No connection
|
MT-RJ Ethernet Cable Connectors
The Ethernet ports on the 100BASE-FX interface module are MT-RJ receptacles. The following table lists the signals for the MT-RJ Ethernet cable connector.
Pin
|
Signal
|
Direction
|
Description
|
1
|
VeeRX
|
|
Receiver signal ground
|
2
|
VccRX
|
<
|
Receive power supply
|
3
|
SD
|
|
Signal Detect
|
4
|
RD-
|
<
|
Receiver data-
|
5
|
RD+
|
<
|
Receiver data+
|
6
|
VccTX
|
>
|
Transmit power supply
|
7
|
VeeTX
|
>
|
Transmit signal ground
|
8
|
Tdis
|
|
Transmit disable
|
9
|
TD+
|
>
|
Transmit data+
|
10
|
TD-
|
>
|
Transmit data-
|
Specifications and Regulatory Compliance Information
Description
|
Specifications
|
Switch and processor capacity
|
10-Gbps shared memory, nonblocking switch fabric up to 32-KB frames
|
Dimensions (H x W x D)
|
Chassis: 10.4 x 17.25 x 18.4 in (26.4 x 43.8 x 46.7 cm)
Processor, switch processor, carrier module, and interface module:
1.2 x 14.4 x 16 in (3.0 x 36.6 x 40.6 cm)
Port adapter: 1.2 x 6.5 x 10 in (3.0 x 16.5 x 25.4 cm)
Power supply: 2.7 x 6.0 x 15.3 in (6.9 x 15.2 x 38.9 cm)
|
Weight
|
Empty chassis: 32 lb (14.51 kg)
Fully populated chassis: approximately 130 lb (58.97 kg)
AC power supply: 11 lb (4.99 kg)
DC power supply: 10 lb (4.54 kg)
|
Airflow
|
95 cfm through the system fan assembly
|
Operating temperature
|
32 to 122F (0 to 50C)
|
Nonoperating temperature
|
-40 to 167F (-40 to 75C)
|
Humidity
|
10 to 90%, noncondensing
|
Altitude
|
-500 to 6,500 ft (-152 to 2000 m)
|
Microprocessor
|
100-Mhz MIPS R4700
|
AC total output
|
388W maximum
|
AC-input voltage
|
100-127/200-240 VAC wide input with power factor correction
|
AC frequency
|
Auto sensing limits: 100 to 127/200 to 240 VAC, 8/4A, 50/60 Hz
|
AC current rating
|
8/4A with the chassis fully populated
|
Power supply load
|
376W maximum configuration, 200W typical with max configuration
|
DC voltages supplied and steady-state maximum current ratings
|
System: +5V @ 70A
+12V @ 2A
+24V @ 0.12A
Processor: +5V @ 15A
+24V @ 25mA
+12V @ 500mA
|
Description
|
Specifications
|
Memory
|
8-MB Flash memory SIMM (upgradable to 16 MB)
64-MB DRAM
256-KB boot EPROM
128-KB SRAM
No Flash PC card installed by default (accepts 8-, 16-, or 20-MB Intel Series 2+ Flash PC cards)
|
Regulatory Compliance
|
CE Marking (European Union)1
UL 1950 (U.S.A.)
CSA C22.2 No. 950 (Canada)
EN60950 (European Union)
IEC60950 (International)
AS/NZS 3260 (Australia/New Zealand)
TS001 (Australia)
21CFR1040 (Laser - U.S.A.)
EN60825 (Laser - European Union)
IEC60825 (Laser - International)
FCC Part 15 (CFR 47) Class A (U.S.A.)
VCCI Class A with UTP and Class B with FTP cables (Japan)
EN55022 Class A with UTP and Class B with FTP cables (European Union)
CISPR 22 Class A with UTP and Class B with FTP cables (International)
AS/NZS 3548 Class A with UTP and Class B with FTP cables (Australia/New Zealand)
EH 55024
EH 50082-1
ET5300 386-2
ICES 003 Class A
|
Products bear CE Marking indicating compliance with the 99/5/EC directive, which includes the following safety and EMC standards.
|
Product Documentation
Catalyst 8510 CSR Documentation
http://www.cisco.com/univercd/cc/td/doc/product/l3sw/8510/index.htm
Catalyst 8510 MSR Documentation
http://www.cisco.com/univercd/cc/td/doc/product/atm/c8510/index.htm
LightStream 1010 Documentation
http://www.cisco.com/univercd/cc/td/doc/product/atm/ls1010s/index.htm
Related Web Pages
Catalyst 8500 Series
http://www.cisco.com/warp/public/cc/pd/si/casi/ca8500/index.shtml
LightStream 1010 ATM Switches
http://www.cisco.com/warp/public/cc/pd/si/lsatsi/ls1010
Layer 3 Backbone
http://www.cisco.com/warp/public/779/largeent/design/L3_backbone.html
Catalyst 8510 CSR Software
(requires CCO authorization)
http://www.cisco.com/cgi-bin/tablebuild.pl/cat8510c
Catalyst 8510 MSR Software
(requires CCO authorization)
http://www.cisco.com/cgi-bin/tablebuild.pl/cat8510m
LightStream 1010 Software
(requires CCO authorization)
http://http://www.cisco.com/cgi-bin/tablebuild.pl/ls1010
Cisco Interactive Quick Start Guides
http://www.cisco.com/mm/quickstart/
Posted: Wed Jul 2 23:10:59 PDT 2003
All contents are Copyright © 1992--2003 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.