There a many ways to configure BIND9. Some of the most common configurations are a caching nameserver, primary master, and a as a secondary master.
-
When configured as a caching nameserver BIND9 will find the answer to name queries and remember the answer when the domain is queried again.
-
As a primary master server BIND9 reads the data for a zone from a file on it's host and is authoritative for that zone.
-
In a secondary master configuration BIND9 gets the zone data from another nameserver authoritative for the zone.
The DNS configuration files are stored in the
/etc/bind
directory. The
primary configuration file is
/etc/bind/named.conf
.
The include line specifies the
filename which contains the DNS options. The
directory line in the /etc/bind/named.conf.options
file tells
DNS where to look for files. All files BIND uses will be
relative to this directory.
The file named /etc/bind/db.root
describes the root nameservers in the world. The servers
change over time, so the
/etc/bind/db.root
file must be maintained
now and then. This is usually done as updates to the bind9 package.
The zone section defines a master
server, and it is stored in a file mentioned in the file option.
It is possible to configure the same server to be a caching name server, primary master, and secondary master. A server and be the Start of Authority (SOA) for one zone, while providing secondary service for another zone. All the while providing caching services for hosts on the local LAN.
The default configuration is setup to act as a caching server. All that is required is simply adding the IP Addresses
of your ISP's DNS servers. Simply uncomment and edit the following in /etc/bind/named.conf.options
:
forwarders {
1.2.3.4;
5.6.7.8;
};
Replace 1.2.3.4 and 5.6.7.8 with the IP Adresses of actual nameservers. |
Now restart the DNS server, to enable the new configuration. From a terminal prompt:
sudo /etc/init.d/bind9 restart
See the section called “dig” for information on testing a caching DNS server.
In this section BIND9 will be configured as the Primary Master for the domain example.com. Simply replace example.com with your FQDN (Fully Qualified Domain Name).
To add a DNS zone to BIND9, turning BIND9 into a Primary Master server, the first step is to edit
/etc/bind/named.conf.local
:
zone "example.com" {
type master;
file "/etc/bind/db.example.com";
};
Now use an existing zone file as a template to create the /etc/bind/db.example.com
file:
sudo cp /etc/bind/db.local /etc/bind/db.example.com
Edit the new zone file /etc/bind/db.example.com
change localhost.
to the FQDN of your server, leaving the additional "." at the end. Change 127.0.0.1 to the
nameserver's IP Address and root.localhost to a valid email address, but with a "." instead
of the usual "@" symbol, again leaving the "." at the end.
Also, create an A record for ns.example.com. The name server in this example:
;
; BIND data file for local loopback interface
;
$TTL 604800
@ IN SOA ns.example.com. root.example.com. (
1 ; Serial
604800 ; Refresh
86400 ; Retry
2419200 ; Expire
604800 ) ; Negative Cache TTL
;
@ IN NS ns.example.com.
@ IN A 192.168.1.10
ns IN A 192.168.1.10
You must increment the Serial Number every time you make changes to the zone file. If you make multiple changes before restarting BIND9, simply increment the Serial once.
Now, you can add DNS records to the bottom of the zone file. See the section called “Common Record Types” for details.
Many admins like to use the last date edited as the serial of a zone, such as 2007010100 which is yyyymmddss (where ss is the Serial Number) |
Once you have made a change to the zone file BIND9 will need to be restarted for the changes to take affect:
sudo /etc/init.d/bind9 restart
Now that the zone is setup and resolving names to IP Adresses a Reverse zone is also required. A Reverse zone allows DNS to resolve an address to a name.
Edit /etc/bind/named.conf.local and add the following:
zone "1.168.192.in-addr.arpa" {
type master;
notify no;
file "/etc/bind/db.192";
};
Replace 1.168.192 with the first three octets of whatever network you are using.
Also, name the zone file |
Now create the /etc/bind/db.192
file:
sudo cp /etc/bind/db.127 /etc/bind/db.192
Next edit /etc/bind/db.192
changing the basically the same options as
/etc/bind/db.example.com
:
;
; BIND reverse data file for local loopback interface
;
$TTL 604800
@ IN SOA ns.example.com. root.example.com. (
2 ; Serial
604800 ; Refresh
86400 ; Retry
2419200 ; Expire
604800 ) ; Negative Cache TTL
;
@ IN NS ns.
10 IN PTR ns.example.com.
The Serial Number in the Reverse zone needs to be incremented on each changes as well.
For each A record you configure in /etc/bind/db.example.com
you need to
create a PTR record in /etc/bind/db.192
.
After creating the reverse zone file restart BIND9:
sudo /etc/init.d/bind9 restart
Once a Primary Master has been configured a Secondary Master is needed in order to maintain the availability of the domain should the Primary become unavailable.
First, on the Primary Master server, the zone transfer needs to be allowed. Add the allow-transfer
option to the example Forward and Reverse zone definitions in /etc/bind/named.conf.local
:
zone "example.com" {
type master;
file "/etc/bind/db.example.com";
allow-transfer { 192.168.1.11; };
};
zone "1.168.192.in-addr.arpa" {
type master;
notify no;
file "/etc/bind/db.192";
allow-transfer { 192.168.1.11; };
};
Replace 192.168.1.11 with the IP Address of your Secondary nameserver. |
Next, on the Secondary Master, install the bind9 package the same way as on the Primary.
Then edit the /etc/bind/named.conf.local
and add the following declarations for the Forward and Reverse zones:
zone "example.com" {
type slave;
file "db.example.com";
masters { 192.168.1.10; };
};
zone "1.168.192.in-addr.arpa" {
type slave;
file "db.192";
masters { 192.168.1.10; };
};
Replace 192.168.1.10 with the IP Address of your Primary nameserver. |
Restart BIND9 on the Secondary Master:
sudo /etc/init.d/bind9 restart
In /var/log/syslog
you should see something similar to:
slave zone "example.com" (IN) loaded (serial 6)
slave zone "100.18.172.in-addr.arpa" (IN) loaded (serial 3)
Note: A zone is only transferred if the Serial Number on the Primary is larger than the one on the Secondary. |