Restrictions on sw* Commands Invoked by drd runcmd

» 

Technical documentation

Complete book in PDF
» Feedback
Content starts here

 » Table of Contents

 » Glossary

 » Index

Options on the Software Distributor commands that can be used with drd runcmd are limited by the need to ensure that operations are DRD-safe. The restrictions include the following:

  • The -F and -x fix=true options are not supported for drd runcmd swverify operations. Use of these options could result in changes to the booted system.

  • The use of double quotation marks and wild card symbols (*, ?) in the command line must be escaped with a backslash character (\), as in the following example:

    drd runcmd swinstall –s depot_server:/var/opt/patches \*
  • Files referenced in the command line must both:

    • Reside in the inactive system image

    • Be referenced in the DRD-safe command by the path relative to the mount point of the inactive system image

    This applies to files referenced as arguments for the -C, -f, -S, -X, and -x logfile options for an sw command run by drd runcmd.

See drd-runcmd(1M) for further information about restrictions on Software Distributor commands invoked by drd runcmd.