background image
Inter-Switch Link Routing
233
an RSFC in slot 1, but it is in module 15. This information will allow you to
connect and configure the internal route processor:
Todd5000> (enable) sh module
Mod Slot Ports Module-Type Model Status
--- ---- ----- ------------------------- ------------- --------
1 1 2 1000BaseX Supervisor IIIG WS-X5550 ok
15 1 1 Route Switch Feature Card WS-F5541 ok
2 2 24 10/100BaseTX Ethernet WS-X5225R ok
3 3 2 UTP OC-3 Dual-Phy ATM WS-X5156 ok
13 13 ASP/SRP
Mod Module-Name Serial-Num
--- ------------------- --------------------
1 00014364176
15 14452699
2 00017581709
3 00014173130
Mod MAC-Address(es) Hw Fw Sw
--- -------------------------------------- ------ ------- -----------
1 00-b0-c2-b2-d0-00 to 00-b0-c2-b2-d3-ff 1.1 5.1(1) 5.2(1)
15 00-30-f2-c8-11-00 to 00-30-f2-c8-11-3f 1.0 12.0(3c)W5 12.0(3c)W5(8a),
2 00-30-7b-36-2b-50 to 00-30-7b-36-2b-67 3.3 4.3(1) 5.2(1)
3 00-10-7b-42-e7-da 2.4 1.3 11.3(8)WA4(11a)3.2(13)
Not only does the command show module provide the module and slot
that each card is in, it provides the serial number and the modules' MAC
addresses. Once you find the module number, you can then connect to that
module using the session command. Here is an example:
Todd5000> (enable)
Todd5000> (enable) session 15
Trying Router-15...
Connected to Router-15.
Escape character is '^]'.
Copyright ©2000 SYBEX , Inc., Alameda, CA